UST OF EQUIPMENT / INSTRUMENTS: (SPECIFICATIONS) Name of the Item: C-arm And Image Intesifier Technical Specification as below- Technical Specifications as follows or better arm Gantry /C—Arm 41. The system should have a minimum of 760 mm free space within the C- Arm to provide a large imaging space. 2. The C-Arm depth should be 680 mm deeper to provide a large imaging space and C-Arm Clarence around the patient and the imaging table 3, The C-Arm should have a manual rotation of +/- 225 to allow the imaging chain to accomplish angled projections 4, The C-Arm should have orbital movement of + 90 /-45 degree for better penetration in Cranio / caudal movement 5. The system should have at least 42 cm of motorized vertical CArm travel capability to adjust the imaging chain height 6. Radius of C-Arm — minimum 680 mm or more 7. The C-Arm should provide side ~ to side (wig-wag + /- 10Deg) and the horizontal travel (minimum 220 mm) movements to allow panning during an imaging Generator & X-Ray Tube 1. The Generator should be Micro processor controlled converter type with output of 7.5 kw or more and minimum 40 KHZ frequency (or higher) 2. The system should operated in full capacity on 220 volts AC, 15 amps 3. Fluoroscopic kVp range : 40-120 kVp or more 4, Fluoroscopic mA range: 0.20 -20.0 mA or more 5. The tube housing heat storage capacity should be a minimum of 1.8 MHU 6. Radiographic kVp range : 40 ~ 120 kVp or more 7. Radiographic m A range: 75 mA or more 8. The generator should be capable of providing pulse fluoroscopy with pulse rate upto 1-25 pulse rates/ sec al yy Pw a 9. The X-ray tube should be a Rotating anode X-ray tube type 10. The tube should have additional safety filtration for the stray or scattered radiation Le. cu filters 11. Boosted fluoroscopy 75 mA or better Image intensifier / TV system (9 Inch I!) 1. Ultra compact CCD/Digital video camera with at least 1024 x 1024K pixels & ADR/AVR control along with super high resolution Two no. 18” flat screen monitors mounted on easy to move integrated trolley having facility of recording devices for archiving of images on a hard disk of about 50, 000 images of 1024 x 1024 pixels memory matrix with upto 32 bit image processing. The system should have reliable technology to produce optimal high quality image even if the region of interest isnot in the centre of image intensifier i.e. multiple matrixes. The following feature must be included: 1. Difference like stack, recursive, edge enahcement filters for noise reduction 2. Radiation free collimation digital image rotation w/o radiation, image rotation, left to right and top to bottom image reversals 3.16 image mosoic display 4. Image archiving possibilities on USB & DVD with it’s viewer software. 5. The system should provide last image hold capability that the last image is displayed on the active ‘monitor after the termination of an exposure. 6. The system must be DICOM 3.0 ready for storage of multiframe capability, print class & media class 7. The system shall allow the user to change the image orientation on the display screen during a live exposure or using the last image hold. Those functions include 8. Sequential image storage display up to 1-8 f/s 1 System & Image management 1. The system should have multi patient database for handling large quantities of image, including dose management report. Digit 2. The system should automatically select proper imaging parameter, kVp and m A during an imaging, but also provide the user to over-ride these setting manually 3. The system should prove zoom 4, The system should provide a real-time post processing edge enhancement capabilities to get other quality according to the density of the tissue, An electronic zoom function, an automatic save 0% gurl Y tr Ww Ax e A function to hard disk, Mosaic Display. The system should be capable of saving more than 10,000 images to the internal hard disk and retrieve stored images later. 6. Real time and automatic brightness and contrast should be provided to optimize displayed image Name of the accessories 1. Suitable Servo Voltage Stabilizer for image handling functions 2. Lead Aprons ~6 in number 3. Thyroid Shield —6 in number System should have CE and US FDA Certificate

You might also like