Dse6010 20 Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

®

DSEGenset

DSE6010/20 ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY

AUTO START & AUTO MAINS FAILURE BS EN 61000-6-2


EMC Generic Immunity Standard for
the Industrial Environment
CONTROL MODULES BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

The DSE6010 is an Auto Start Both modules offer electronic TEMPERATURE


Control Module and the DSE6020 (CAN) and non-electronic (magnetic BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
is an Auto Mains (Utility) Failure pick-up/alternator sensing) engine BS EN 60068-2-2
Control Module suitable for a wide versions and offer a number of Bb/Be Dry Heat +70 oC
variety of single, diesel or gas, flexible inputs, outputs and engine VIBRATION
gen-set applications. protections so the system can be BS EN 60068-2-6
easily adapted to suit a wide range Ten sweeps in each of three
major axes
Monitoring speed, frequency, of application demands. 5 Hz to 8 Hz @ +/-7.5 mm,
voltage, current, oil pressure, 8 Hz to 500 Hz @ 2 gn
coolant temperature and fuel level, The modules can be easily HUMIDITY
the modules will display warnings, configured using the DSE BS EN 60068-2-30
shutdown and engine status Configuration Suite PC software. Db Damp Heat Cyclic 20/55 oC
@ 95% RH 48 Hours
information on the back-lit LCD Selected front panel editing is also BS EN 60068-2-78
screen and illuminated LED. available. Cab Damp Heat Static 40 oC
@ 93% RH 48 Hours

SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS

DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the optional sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

4 2 3

USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER


PORT INPUTS SENDERS STOP SUPPLY 8-35V

DEUTZ
DSE6010/20 ISUZU
PERKINS
CATERPILLAR
7
MTU
VOLVO
CUMMINS
OTHER
SCANIA

MAINS (UTILITY) DC OUTPUTS GENERATOR SENSING CHARGE FUEL & CRANK ELECTRONIC
SENSING ALTERNATOR OUTPUTS ENGINES OR
DSE6020 ONLY (Flexible with CAN) MAGNETIC PICK-UP

VOLTS CURRENT VOLTS


D+
+ + W/L +

1ph 1 1 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N N

ISSUE 2
®

DSEGenset

DSE6010/20 SPECIFICATION

DC SUPPLY

AUTO START & AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING


8 V to 35 V Continuous

CONTROL MODULES CRANKING DROPOUTS


Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
FEATURES supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.

DSE6020 MAXIMUM OPERATING CURRENT


150 mA at 12 V, 80 mA at 24 V

MAXIMUM STANDBY CURRENT


50 mA at 12 V, 30 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V
DSE6010
MAINS (UTILITY) DSE6020 ONLY
VOLTAGE RANGE
15 V - 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS
OUTPUT A (FUEL)
2 A DC at supply voltage

OUTPUT B (START)
2 A DC at supply voltage

AUXILIARY OUTPUTS C,D,E & F


2 A DC at supply voltage

GENERATOR
VOLTAGE RANGE
15 V - 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

KEY FEATURES • Current monitoring and protection • Multiple engine parameters are MAGNETIC PICK UP
• Back-lit icon LCD display • Power monitoring monitored simultaneously VOLTAGE RANGE
+/- 0.5 V to 70 V
• Front panel editing (kW, kV A, kV Ar) • Module can be configured to
• LED and LCD alarm indication • 3 Phase Mains (Utility) suit individual applications DIMENSIONS
• Power Save mode monitoring (DSE6020 only) • Compatible with a wide range OVERALL
215 mm x 158 mm x 42 mm
• CAN and Magnetic Pick-up/Alt. • Test button (DSE6020 only) of CAN engines
8.5” x 6.2” x 1.6”
versions available (specify on • Battery Voltage monitoring • Uses DSE Configuration Suite
ordering) • Engine pre-heat PC software for simplified PANEL CUT-OUT
182 mm x 137 mm
• PC and front panel • Hours counter configuration
7.2” x 5.4”
configuration • Comprehensive shutdown or • IP65 rating (with optional
• 4 Digital inputs warning on fault condition gasket) offers increased MAXIMUM PANEL THICKNESS
8 mm
• 3 Analogue inputs resistance to water ingress
0.3”
• 6 Outputs (4 configurable on KEY BENEFITS • Licence-free PC software
Magnetic Pick-up/Alt., 6 • Automatically transfers between
configurable on CAN version) mains (utility) and generator
• Configurable timers and alarms power (DSE6020 only)
• Alternative configuration • Hours counter provides accurate
• Event Log (5) information for monitoring and
• Remote Start input maintenance periods
• 3 Phase generator monitoring • User-friendly set-up and button
layout

RELATED MATERIALS
TITLE PART NO’S
DSE6010 Installation Instructions 053-076
DSE6020 Installation Instructions 053-077
DSE6000 Operator Manual 057-112
DSE6000 Configuration Suite PC Manual 057-114

DEEP SEA ELECTRONICS PLC UK


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303
EMAIL [email protected] WEBSITE www.deepseaplc.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-079/03/11 (3)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

You might also like