DC/DC Converters: Features
DC/DC Converters: Features
DC/DC Converters: Features
Features UL 60950-1
◆ Cost optimized design in DIP-24 package
◆ Fully regulated output
◆ Output ripple & noise 30 mVp-p typ.
◆ Short circuit protection
◆ Operating temperature
range –40°C to +75°C at full load
◆ I/O isolation 1’500 VDC
◆ Input filter meet EN 55022, class A
◆ No minimum load required
◆ Industry standard pinout
◆ 3-year product warranty
Models
Ordercode Input voltage range Output voltage Output current max. Efficiency typ.
TEM 3-0511N 5 VDC 600 mA 70 %
TEM 3-0512N 12 VDC 250 mA 78 %
TEM 3-0513N 5 VDC ±10% 15 VDC 200 mA 78 %
TEM 3-0522N ±12 VDC ±125 mA 78 %
TEM 3-0523N ±15 VDC ±100 mA 78 %
TEM 3-1211N 5 VDC 600 mA 74 %
TEM 3-1212N 12 VDC 250 mA 80 %
TEM 3-1213N 12 VDC ±10% 15 VDC 200 mA 80 %
TEM 3-1222N ±12 VDC ±125 mA 81 %
TEM 3-1223N ±15 VDC ±100 mA 82 %
TEM 3-2411N 5 VDC 600 mA 75 %
TEM 3-2412N 12 VDC 250 mA 80 %
TEM 3-2413N 24 VDC ±10% 15 VDC 200 mA 80 %
TEM 3-2422N ±12 VDC ±125 mA 81 %
TEM 3-2423N ±15 VDC ±100 mA 82 %
http://www.tracopower.com Page 1 of 3
DC/DC Converters
TEM 3N Series 3 Watt
Input Specifications
Input current no load / full load 5 Vin models: 90 mA / 800 mA typ.
12 Vin models: 45 mA / 320 mA typ.
24 Vin models: 22 mA / 160 mA typ.
Surge voltage (1 sec. max.) 5 Vin models: 7.5 V max.
12 Vin models: 15 V max.
24 Vin models: 30 V max.
Output Specifications
Voltage set accuracy ±2 %
Regulation
– Input variation Vin min. to Vin max. ±0.5 % max.
– Load variation 10 – 100 %
single output models: ±0.5 % max.
dual output models balanced load: ±3.0 % max.
Ripple and noise (20 MHz Bandwidth) 60 mVp-p max. (30 mVp-p typ.)
Temperature coefficient ±0.02 %/K
Current limitation >120 % of Iout max., constant current
Short circuit protection continuous, automatic recovery
Capacitive load 5 VDC models: 470 µF max.
other models: 100 µF max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case +95°C max.
– Storage –50°C to +125°C
Derating 5 %/K above +75°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >700‘000 h
Isolation voltage (60 sec.) – Input/Output 1’500 VDC
Isolation capacitance – Input/Output 300 pF typ.
Isolation resistance – Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 300 kHz typ. (Pulse frequency modulation PFM)
Safety standards CAN/CSA-C22.2 No 60950-1-07, 2nd ed; A1:2011
ANSI/UL No. 60950-1, 2nd ed.; A1:2011
IEC 60950-1:2005 (2nd edition); A1:2009
EN 60950-1:2006/A11:2009/A1:2010/12:2011
www.tracopower.com/overview/tem3n
– Certification documents
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com Page 2 of 3
DC/DC Converters
TEM 3N Series 3 Watt
Physical Specifications
Casing material non-conductive black plastic (UL 94V-0)
Weight 12.4 g (0.43 oz)
Soldering temperature max. 260°C / 10 sec.
1 2 3 10 11 12 Pin-Out
15.25 (0.60)
20.3 (0.80)
11 +Vout +Vout
12 –Vin (GND) –Vin (GND)
(0.40)
10.2
15 –Vout Common
22 ntc. Common
2.54 2.54 17.78 (0.70) 2.54 2.54 23 ntc. –Vout
(0.1) (0.1) (0.1) (0.1) 24 +Vin (Vcc) +Vin (Vcc)
2.0 27.94 (1.10)
(0.08)
ntc. = not to connect
31.8 (1.25)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
Rev. July 26, 2018
www.tracopower.com Page 3 of 3