D1u86p W 1600 12 HBXDC

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

www.murata-ps.

com PRODUCT OVERVIEW


D1U86P-W-1600-12-HBxDC Series
86mm 1U Front End AC-DC Power Supply

The D1U86P-W-1600-12-HBxDC products are high efficiency 1600 watt, power factor corrected front end
supplies with a 12V main output and a 12V (30W) standby. They have current sharing and up to 8 supplies
may be operated in parallel. The supplies may be hot plugged, they recover from overtemperature faults,
and have logic and PMBus monitoring and control. Their low profile 1U package and >38.6W/cubic inch
power density make them ideal for delivering reliable, efficient power to servers, workstations, storage
systems and other 12V distributed power systems.
ORDERING GUIDE
Power Output; AC Line Main Standby
Part Number Airflow
FEATURES (90-264V) (108-264V) (180-264V) Output Output
D1U86P-W-1600-12-HB4DC Back to front

1600W output power 1200W 1350W 1600W 12V 12V
D1U86P-W-1600-12-HB3DC Front to Back

94% minimum efficiency at 50% load

12V main output INPUT CHARACTERISTICS
Parameter Conditions Min. Nom. Max. Units

12V standby output of 30W Input Voltage Operating Range 90 115/230 264 Vac

1U height: 3.4" x 7.75" x 1.59" Frequency 47 50/60 63 Hz
Turn-on Voltage Ramp up 81 89

38.6 Watts per cubic inch density Vac
Turn-off Voltage Ramp down 70.5 73 78

N+1 redundancy, including hot plugging (up to Maximum Input Current 1200W, 100Vac 14.1 Arms
8 in parallel) Inrush Current At 264Vac at 25°C cold start 35 Apk
Power Factor At 230Vac, half load 0.98

Current sharing on 12V main output 20% load 90
Efficiency (230Vac) excluding

Overvoltage, overcurrent, 50% load 94 %
fan load
overtemperature protection 100% load 91

Internal cooling fan (variable speed) OUTPUT VOLTAGE CHARACTERISTICS

PMBus™ / I²C interface monitoring and control Output
Parameter Conditions Min. Typ. Max. Units
Voltage

RoHS compliant
Voltage Set Point 50% load 12.17 12.2 12.23
Vdc
Line and Load Regulation 11.4 12.6
Droop 3.10 mV/A
Ripple Voltage & Noise1 20MHz Bandwidth 120 mV p-p
12V
Output Current (230 Vac)2 0 133.4 A
Output Current (120 Vac)2 0 112.5 A
Output Current (100 Vac)2 0 100.0 A
Load Capacitance 10,000 μF
Voltage Set Point 50% load 11.97 12.0 12.02 Vdc
12VSB Ripple Voltage & Noise1 20MHz Bandwidth 120 mV p-p
Output Current 0 2.5 A
1
Ripple and noise measured with a parallel combination of a 1.0μF ceramic and 10μF tantalum capacitor on each of the power module
outputs. A short coaxial cable connected directly to the input of a scope is required.
2
To meet ripple and transient step load specifications a minimum load of 4A is required.
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html
www.murata-ps.com/en/3d/acdc.html

Available now at
http://power.murata.com/en/3d/acdc.html

CB
Test Certificate
and Test Report
For full details go to
www.murata-ps.com/rohs

www.murata-ps.com/support
D1U86P-W-1600-12-HBxDC.A01 Page 1 of 6
D1U86P-W-1600-12-HBxDC Series
86mm 1U Front End AC-DC Power Supply

OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Output Rise Monotonicity No voltage excursion
Startup Time AC ramp up 1.5 3 s
12V, 50% load step, 1.0Aμs di/dt 600
Transient Response mV
12VSB, 50% load step,1.0Aμs di/dt 600
Current sharing accuracy (up to 8 in parallel)3 At 100% load ±5 %
Hot Swap Transients All outputs remain in regulation 5 %
Holdup Time At full load 12 ms
3
Load current of 100% applies to each power module max load connected in an N+1 configuration; therefore the total load will be “N” x 100% . The share accuracy of ±5% is a fixed percentage irrespective
of total loading and number of units connected in parallel.

ENVIRONMENTAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Storage Temperature Range -40 85
°C
Operating Temperature Range 0 55
Operating Humidity Noncondensing 5 90
%
Storage Humidity 5 95
Altitude (without derating at 45°C) 3000 m
Shock 30G non operating
Vibration 10-500Hz, 0.5G (non-operational)
MTBF Per Telcordia SR-322 M1C1@ 40°C 559K hrs
Acoustic 65 dBA/@1m
CSA 60950-1-07+A1:2011
ANSI/UL 60950-1-2011, Second Edition
Safety Approvals
IEC 60950-1:2005 (2nd Edition) + A1:2009
EN 60950-1:2006 +A11:2009 +A1:2010
Input Fuse Power Supply has internal 16A/250V fast blow fuse on the AC line input
Weight 2.33/1.06 lbs/Kg

PROTECTION CHARACTERISTICS
Output
Parameter Conditions Min. Typ. Max. Units
Voltage
An OTP warning will be issued via the PMBus™
interface when the air inlet exceeds 65°C;
Overtemperature (intake) however the power module shall not shut down 65 °C
until critical internal hotspot temperatures are
exceeded.
Overvoltage Latching 13.2 14.4 V
Shutdown of the output followed by auto- recovery
Overcurrent at 220Vac after one second. The output shall attempt three 140 153
12V such auto-recovery attempts and then enter a per-
A
manent latched state. Recovery of the permanent
Overcurrent at 120Vac latched state shall require cycling of the incoming 118 129
AC source or toggling of the PSON# signal.
Overvoltage Latching 13.2 14.4 V
12VSB
Overcurrent Autorecovery 2.75 3 A

ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Input to Output - Reinforced 3000 Vrms
Insulation Safety Rating / Test Voltage
Input to Chassis - Basic 1500 Vrms
Isolation Output to Chassis 500 Vdc
Leakage Current 1.5mA at 264Vac, 50/60Hz

www.murata-ps.com/support
D1U86P-W-1600-12-HBxDC.A01 Page 2 of 6
D1U86P-W-1600-12-HBxDC Series
86mm 1U Front End AC-DC Power Supply

EMISSIONS AND IMMUNITY


Characteristic Standard Compliance
Input Current Harmonics IEC/EN 61000-3-2 Complies
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies
Conducted Emissions FCC 47 CFR Part 15/CISPR 22/EN55022 Class A, 6dB margin
ESD Immunity IEC/EN 61000-4-2 Level 3 criteria A
Radiated Field Immunity IEC/EN 61000-4-3 Level 3 criteria B
Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3 criteria A
Surge Immunity IEC/EN 61000-4-5 Level 3 criteria A
Radiated Field Conducted Immunity IEC/EN 61000-4-6 Level 3 criteria A
Magnetic Field Immunity IEC/EN 61000-4-8 3 A/m criteria B
230Vin, 100% load, Phase 0°, Dip 100% Duration 10ms (A)
Voltage dips, interruptions IEC/EN 61000-4-11 230Vin, 50% load, Phase 0°, Dip 100% Duration 20ms (VSB:A, V1:A)
230Vin, 100% load, Phase 0°, Dip 100% Duration > 20ms (VSB, V1:B)

STATUS INDICATORS AND CONTROL SIGNALS


Signal Description
PSON# Low = main output on; PSON# can be permanently tied to GND within the host system.
Short pin pulled down on p/s; pulled up to either 3.3V or 12V (max) in the host system. For 3.3V use a 5.11KΩ resistor; for 12V,
PRESENT#
use a 21KΩ resistor.
PS INTERRUPT Open drain PMBus™ signal; can be left open if not used.
PMBus™ Address; ADDR can be grounded or left open if not used. If grounded, the address will be 000, if it is open, the default
ADDR
address will be 111.
ISHARE Analog representation of main output current; can be left open if not used.
PSOK4 A three level signal based on AC input and DC output status; can be left open if not used.
I2C CLOCK I2C clock
I2C DATA I2C data
LED State Mode Operating Condition
1. Off AC Turn-off AC Input is below minimum power-supply turn-on specification
2. Green – blinking 1Hz Standby Power supply standby output is operating within normal parameters and main output is disabled
3. Green – solid Power-good Power supply standby & main outputs are operating within normal parameters and delivering power
4. Yellow – blinking 1Hz Warning Warning condition in power supply has been detected
5. Yellow – solid Fault Fault condition in power supply has been detected.
3 See truth table below for operation.

OUTPUT CONNECTOR AND SIGNAL SPECIFICATION

Pin# Function Pin Type Description


14-26, 39-51 RTN Power Ground Power and Standby Return
1-13, 52-64 12V Power 12V Output Power Supply Output Card Edge
37 12VSB Power 12V Standby Output
Active low; interrupt line for power supply 64 1
38 PSINTERRUPT Output
fault & warning detection as per PMBus spec
36 PRESENT# Input Power Supply Present Signal (shortest pin)
Combination of there power supply output
indicator signals:
35 PSOK Analog output 1. AC input OK
2. Power Good
3. Power Supply Fault
Analog representation of main output current.
34 ISHARE Analog I/O Typical analog voltage shall be 60.15mV/Amp
of main output current.
33 PSON# Input Power Supply on/off control signal 33 32
32 SCL Input SMBus/PMBus Clock
31 SDA I/O SMBus/PMBus Data PCB Top Side PCB Bottom Side

30 GND Analog I/O Power Supply Signal Ground


29 N/A N/A Reserved; no User connection
28 N/A N/A Reserved; no User connection
27 ADDR Analog input PMBus Address

www.murata-ps.com/support
D1U86P-W-1600-12-HBxDC.A01 Page 3 of 6
D1U86P-W-1600-12-HBxDC Series
86mm 1U Front End AC-DC Power Supply

CONNECTOR AND SIGNAL SPECIFICATION4 PSOK TRUTH TABLE VS. ANALOG OUTPUT
DC_OK_H PWR_GOOD_H PS_FAULT_L PSOK OPERATION MODE
0 0 1 < 0.1Vdc No DC Input
0 1 1 (1/3) VDD Invalid
1 0 1 (2/3) VDD VDD = 3.3Vdc Standby
1 1 1 VDD Power Good
X X 0 0.2-0.4Vdc PS Fault

DERATING CURVES

Output Current Derating vs. Ambient Temperature (back to front airflow)


D1U86P‐W‐1600‐HB4DC; VSB 1.0A
12Vdc @90Vac ‐ 113A to 45°C; derates to 90A at 50°C
140
Main Output current (Adc)

120
100
80
90V
60
120V
40
20 180V +

0
25 30 35 40 45 50 55
Ambient Temperature (°C)

Output Current Derating vs. Ambient Temperature (front to back airflow)


D1U86P‐W‐1600‐12‐HB3DC; VSB 2.5A (No Derating)
140
120
Main Output current (Adc)

100
80
90V
60
120V
40
180V+
20
0
25 30 35 40 45 50 55
Ambient Temperature (°C)

www.murata-ps.com/support
D1U86P-W-1600-12-HBxDC.A01 Page 4 of 6
D1U86P-W-1600-12-HBxDC Series
86mm 1U Front End AC-DC Power Supply

WIRING DIAGRAM FOR OUTPUT

1-13, 52-64 1-13, 52-64

Main output
load
RTN RTN 14-26, 39-51
14-26, 39-51

D1U86 12VSB 12VSB D1U86


37 37

PSON# PSON# 33
33 VSB load
FET,BJT,wire FET,BJT,wire
or switch (debounced) or switch (debounced)
to turn on 12V main to turn on 12V main
output output

RTN RTN

CURRENT SHARING NOTES


Main Output: Current share is achieved using the droop method. Nominal output voltage (12.20V) is achieved at 50% load and output voltage droops at a rate of
3.10mv per amp increase. Startup of parallel power supplies is not internally synchronized. If more than 1600W combined power is needed, start-up synchroniza-
tion must be provided by using a common PS_ON signal. To account for ±5% full load current sharing accuracy and the reduction in full load output voltage due to
droop, available output power must be derated by 10% when units are operated in parallel.
Standby output can be tied together for redundancy but total combined output power must not exceed 30W, Internal MOSFET ORING devices are used

www.murata-ps.com/support
D1U86P-W-1600-12-HBxDC.A01 Page 5 of 6
D1U86P-W-1600-12-HBxDC Series
86mm 1U Front End AC-DC Power Supply

MECHANICAL DIMENSIONS
197.70±0.65
137.70 REF 16.50±0.30

39.90±0.50
3.00±0.25

9.00±0.30

240.75 REF

51.36±0.30

83.52±0.30

8.00±0.30
3.30±0.25

2X3.20±0.25 198.05±0.65 1.41 ±0.50


190.90±0.65

AIR FLOW DIRECTION FRONT TO BACK

AIR FLOW DIRECTION BACK TO FRONT

0.062"

40.50±0.50 6.80±0.40

86.40±0.60 4.20±0.40 10.25±0.40 9.56±0.25


191.70±0.50
AC input connector: IEC 320-C14
3.4" x 7.78" x 1.59" [86.4mm x 197.7mm x 40.5mm]

MATING CONNECTOR
Part Number Description
FCI 10053363-200LF Right Angle
FCI 10046971-001LF Vertical

OPTIONAL ACCESSORIES
Description Part Number
12V D1U86P Output Connector Card D1U86P-12-CONC

APPLICATION NOTES
Document Number Description
ACAN-50 D1U86P Output Connector Card
ACAN-51 D1U86P Communication Protocol

This product is subject to the following operating requirements


Murata Power Solutions, Inc.
and the Life and Safety Critical Application Sales Policy:
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Refer to: http://www.murata-ps.com/requirements/
ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice. © 2015 Murata Power Solutions, Inc.

www.murata-ps.com/support
D1U86P-W-1600-12-HBxDC.A01 Page 6 of 6

You might also like