Resuwall FX System Guide SW
Resuwall FX System Guide SW
RESUWALL FX
INTERIOR WALL SYSTEM
Sherwin-Williams Resuwall FX Interior Flexible
Wall System is a multilayer, high build wall surfacing
system that utilizes two coats of a flexible epoxy 3
2
membrane as a base and a high solids urethane 1 1
enamel topcoat for chemical resistance, color 0
BENEFITS
• Crack bridging 0 Primer 2 First Finish Coat
• Impact resistant
• UV resistant, color stable 1 Base Coat (2 coats) 3 Final Finish Coat
• High chemical resistance
• Thermal shock resistant
• Ease of installation
• Waterproofing
• 4685W POLY-COTE™ Chemical TYPICAL PHYSICAL PROPERTIES
• Available with an antimicrobial agent
Hardness, Shore D
• Resistant to: ASTM D 2240
23
28 Day Exposure @ 72°F Result Tensile Strength
1,200 psi
NE= No Effect ASTM D 412
Elongation
Alcohol NE 145%
ASTM D 412
Ethylene Glycol NE Adhesion
300 psi Substrate failure
Fats, Oils & Sugars NE ACI 503R
Gasoline, Diesel & Kerosine NE Flammability Self-Extinguishing over concrete
Hydrochloric Acid (<35%) NE Thermal Cycling
No Cracking
ASTM C 884 (24 hours, 6°F to 77°F)
Lactic Acid (Milk) NE
Wood 24”
Mineral Oils NE Gardner Impact
Cement Board 18”
ASTM 2794-84
Most Organic Solvents NE Drywall 12”
Muriatic Acid NE Permeability 0.01 grains/ft2 /24 hrs./
MIL-I-16923 @ 95% humidity inch thickness
Nitric Acid (<10%) NE Will not support growth of fungus
Nitric Acid (<30%) Slight Softening Fungus & Bacteria Resistance
or bacteria per test
MIL-D-3134F Sec. 4.4.2.11
PM Acetate NE specified TT-P-34
Phosphoric Acid (<50%) NE ASTM D = Resin only
Potassium Hydroxide (<50%) NE
Sodium Hydroxide (<50%) NE
Sulfuric Acid (<50%) Slight Gloss Loss
Water (Distilled) NE
USES LIMITATIONS
• Commercial kitchens and service corridors • Avoid gypsum-based substrate or repair materials
• Pharmaceutical facilities and laboratories in continuously wet areas
• Healthcare and clean rooms
• Animal holding
• Food and beverage facilities
• Locker rooms, showers and restrooms
• Packaging and storage areas
• Cage and skid wash areas
APPLICATION INFORMATION
THEORETICAL COVERAGE
VOC MIXED APPLICATION STEP MATERIAL MIXED RATIO PACKAGING
PER COAT CONCRETE
<100 g/L Body Coat (2 coats) 3552W 1:1 100-200 sq. ft./gal 2 or 10 gals
<100 g/L First Finish Coat 3479 2:1 300-350 sq. ft./gal 3 or 15 gals
<50 g/L Final Finish Coat 4685W 1:1 400-500 sq. ft./gal 4 or 20 gals
If an additional coat of 4685W is required, it is recommended the surface be sanded with a fine grit medium (150 grit or finer), and then solvent wiped
prior to recoating, even if within the recoat window.
2. Add 1 part 3552WA (resin) to 1 part 3552B (hardener) by 4. Allow to cure overnight. Allow to cure 48 hours before water
volume. Mix with low-speed drill and Jiffy mixer for three exposure and 7 days for full chemical resistance. In cool and/or
minutes until uniform. To ensure proper system cure and high humidity conditions, a surface film may form which can
performance, strictly follow mix ratio recommendations. be washed with soap and water.
3. 3552W may be applied via 3/8” roller that has had “fuzz”
removed with tape or solvent washing. Can also be applied
via a brush. Apply at a spread rate of 160-200 sq. ft. per
gallon to yield 8-10 mils WFT evenly with no runs. Coverage
will vary depending upon porosity of the substrate and
surface texture. Roller application will leave a stipple finish,
a final backroll with a short nap (1/4” or 3/16”) roller or foam
roller will reduce but not eliminate the stipple.
4. Allow to cure overnight before applying second base coat.
5. Mix and apply 3552W as described in previous step. Roller
application will require a light sanding, pole sander with an
open screen and solvent wipe to remove lint, runs, or other
debris prior to application of the finish coat.
6. Allow to cure overnight.
SPRAY APPLICATION: Contact the Sherwin-Williams
Technical Service Department.
CLEANUP DISCLAIMER
Clean up mixing and application equipment immediately The information and recommendations set forth in this
after use. Use toluene or xylene. Observe all fire and document are based upon tests conducted by or on behalf
health precautions when handling or storing solvents. of The Sherwin-Williams Company. Such information and
recommendations set forth herein are subject to change and
SAFETY PRECAUTIONS pertain to the product offered at the time of publication.
Refer to the SDS sheet before use. Published technical data and Consult www.sherwin-williams.com/resin-flooring to obtain
instructions are subject to change without notice. Contact your the most recent Product Data information and Application
Sherwin-Williams representative for additional technical data instructions.
and instructions.
WARRANTY
MATERIAL STORAGE The Sherwin-Williams Company warrants our products to
Store materials in a temperature controlled environment be free of manufacturing defects in accord with applicable
(40°F-90°F) and out of direct sunlight. Keep resins, hardeners, Sherwin-Williams quality control procedures. Liability for
and solvents separated from each other and away from sources products proven defective, if any, is limited to replacement of
of ignition. the defective product or the refund of the purchase price paid
for the defective product as determined by Sherwin-Williams.
MAINTENANCE
Occasional inspection of the installed material and spot repair NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE
can prolong system life. For specific information, contact the BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED, STATUTORY,
Sherwin-Williams Technical Service Department. BY OPERATION OF LAW OR OTHERWISE, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.