SYSTEM GUIDE

RESUWALL FX
INTERIOR WALL SYSTEM
Sherwin-Williams Resuwall FX Interior Flexible
Wall System is a multilayer, high build wall surfacing
system that utilizes two coats of a flexible epoxy 3
2
membrane as a base and a high solids urethane 1 1
enamel topcoat for chemical resistance, color 0

and gloss retention. This unique system offers a


competitive advantage over reinforced rigid epoxy
systems while providing superior crack bridging and
impact resistance.

BENEFITS
• Crack bridging 0 Primer 2 First Finish Coat
• Impact resistant
• UV resistant, color stable 1 Base Coat (2 coats) 3 Final Finish Coat
• High chemical resistance
• Thermal shock resistant
• Ease of installation
• Waterproofing
• 4685W POLY-COTE™ Chemical TYPICAL PHYSICAL PROPERTIES
• Available with an antimicrobial agent
Hardness, Shore D
• Resistant to: ASTM D 2240
23
28 Day Exposure @ 72°F Result Tensile Strength
1,200 psi
NE= No Effect ASTM D 412
Elongation
Alcohol NE 145%
ASTM D 412
Ethylene Glycol NE Adhesion
300 psi Substrate failure
Fats, Oils & Sugars NE ACI 503R
Gasoline, Diesel & Kerosine NE Flammability Self-Extinguishing over concrete
Hydrochloric Acid (<35%) NE Thermal Cycling
No Cracking
ASTM C 884 (24 hours, 6°F to 77°F)
Lactic Acid (Milk) NE
Wood 24”
Mineral Oils NE Gardner Impact
Cement Board 18”
ASTM 2794-84
Most Organic Solvents NE Drywall 12”
Muriatic Acid NE Permeability 0.01 grains/ft2 /24 hrs./
MIL-I-16923 @ 95% humidity inch thickness
Nitric Acid (<10%) NE Will not support growth of fungus
Nitric Acid (<30%) Slight Softening Fungus & Bacteria Resistance
or bacteria per test
MIL-D-3134F Sec. 4.4.2.11
PM Acetate NE specified TT-P-34
Phosphoric Acid (<50%) NE ASTM D = Resin only
Potassium Hydroxide (<50%) NE
Sodium Hydroxide (<50%) NE
Sulfuric Acid (<50%) Slight Gloss Loss
Water (Distilled) NE

USES LIMITATIONS
• Commercial kitchens and service corridors • Avoid gypsum-based substrate or repair materials
• Pharmaceutical facilities and laboratories in continuously wet areas
• Healthcare and clean rooms
• Animal holding
• Food and beverage facilities
• Locker rooms, showers and restrooms
• Packaging and storage areas
• Cage and skid wash areas

DESIGNED TO PERFORM sherwin-williams.com/resin-flooring


RESUWALL FX INTERIOR WALL SYSTEM
SYSTEM GUIDE

SURFACE PREPARATION — CONCRETE


INSTALLATION
Consult the Surface Preparation Form G-1 for surface
Sherwin-Williams High Performance Flooring materials shall
preparation for gypsum board, concrete block, plywood
only be installed by approved contractors. The following
or concrete masonry unit (CMU).
information is to be used as a guideline for the installation of
the Resuwall FX Interior Flexible Wall System. Contact the
Sherwin-Williams Technical Service Department for assistance TEMPERATURE
prior to application. Throughout the application process, substrate temperature
should be 50-90°F. Substrate temperature must be at least
SURFACE PREPARATION — GENERAL 5ºF above the dew point. Applications on concrete substrate
should occur while temperature is falling to lessen off gassing.
Sherwin Williams systems can be applied to a variety of
The material should not be applied in direct sunlight, if possible.
substrates if the substrate is properly prepared. Preparation
Protect material from freezing prior to installation.
of surfaces other than concrete will depend on the type of
substrate, such as wood, concrete block, quarry tile, etc.
Should there be any questions regarding a specific substrate
or condition, please contact the Sherwin-Williams Technical
Service Department prior to starting the project. Refer to
Surface Preparation Form G-1.

APPLICATION INFORMATION
THEORETICAL COVERAGE
VOC MIXED APPLICATION STEP MATERIAL MIXED RATIO PACKAGING
PER COAT CONCRETE

<100 g/L Primer 3479 2:1 300-350 sq. ft./gal 3 or 15 gals

<100 g/L Body Coat (2 coats) 3552W 1:1 100-200 sq. ft./gal 2 or 10 gals

<100 g/L First Finish Coat 3479 2:1 300-350 sq. ft./gal 3 or 15 gals

<50 g/L Final Finish Coat 4685W 1:1 400-500 sq. ft./gal 4 or 20 gals

If an additional coat of 4685W is required, it is recommended the surface be sanded with a fine grit medium (150 grit or finer), and then solvent wiped
prior to recoating, even if within the recoat window.

DESIGNED TO PERFORM sherwin-williams.com/resin-flooring


RESUWALL FX INTERIOR WALL SYSTEM
SYSTEM GUIDE

BLOCK FILLER INTERMEDIATE COAT


OPTIONAL MIXING AND APPLICATION
BLOCK FILLER may be used to smooth texture. Contact your 1. Premix 3479A (resin) using a low-speed drill and Jiffy mixer.
local Sherwin-Williams representative to design a block filling Mix for one minute until uniform, exercising caution not to
system that meets project filling and/or leveling and smoothness whip air into the materials.
requirements. 2. Add 2 parts 3479A (resin) to 1 part 3479B (hardener),
mix with low-speed drill and Jiffy mixer for three minutes until
PRIMER uniform. Apply material using a 1/4” short nap roller at a
spread rate of 300-350 sq. ft. per gallon to yield 5 mils WFT.
MIXING AND APPLICATION
3. Allow to cure for a minimum of 3 hours depending upon
1. Premix 3479A (resin) using a low-speed drill and Jiffy mixer.
air movement.
Mix for one minute until uniform, exercising caution not to
whip air into the materials. 4. Sand any imperfections prior to applying finish coat.
2. Add 2 parts 3479A (resin) to 1 part 3479B (hardener),
mix with low-speed drill and Jiffy mixer for three minutes INTERMEDIATE COAT
until uniform. Apply material using a 1/4” or 3/8” nap roller
MIXING AND APPLICATION
at a spread rate of 300-350 sq. ft. per gallon to yield 4-5 mils
WFT depending upon substrate. 1. Premix 4685WA (resin) using a low-speed drill and Jiffy
mixer. Mix for one minute until uniform, exercising caution not
3. Allow to cure for a minimum of 3-4 hours depending upon
to introduce air into the material.
air movement before applying base coat.
2. Add 1 part 4685WA (resin) to 1 part 4685B (hardener) by
*3479 should only be used on unpainted, porous surfaces.
volume. Mix with low-speed drill and Jiffy mixer for three
If the surface is painted with latex or an epoxy coating, clean
minutes until uniform. To ensure proper system cure and
and abrade the surface, then apply the 3479 base coat.
performance, strictly follow mix ratio recommendations.
3. 4685W may be applied via spray, roller or brush. Apply using
BASE COAT (2 COATS) a 1/4” nap non-shedding, urethane enamel roller at a spread
MIXING AND APPLICATION rate of 400-500 sq. ft. per gallon evenly with no runs. Note:
1. Premix 3552WA (resin) using a low-speed drill and Jiffy Roller application will leave a stipple finish. A final roll with a
mixer. Mix for one minute until uniform, exercising caution sponge roller will reduce but not eliminate stipple. Do not
not to introduce air into the material. apply 4685W above 85°F.

2. Add 1 part 3552WA (resin) to 1 part 3552B (hardener) by 4. Allow to cure overnight. Allow to cure 48 hours before water
volume. Mix with low-speed drill and Jiffy mixer for three exposure and 7 days for full chemical resistance. In cool and/or
minutes until uniform. To ensure proper system cure and high humidity conditions, a surface film may form which can
performance, strictly follow mix ratio recommendations. be washed with soap and water.

3. 3552W may be applied via 3/8” roller that has had “fuzz”
removed with tape or solvent washing. Can also be applied
via a brush. Apply at a spread rate of 160-200 sq. ft. per
gallon to yield 8-10 mils WFT evenly with no runs. Coverage
will vary depending upon porosity of the substrate and
surface texture. Roller application will leave a stipple finish,
a final backroll with a short nap (1/4” or 3/16”) roller or foam
roller will reduce but not eliminate the stipple.
4. Allow to cure overnight before applying second base coat.
5. Mix and apply 3552W as described in previous step. Roller
application will require a light sanding, pole sander with an
open screen and solvent wipe to remove lint, runs, or other
debris prior to application of the finish coat.
6. Allow to cure overnight.
SPRAY APPLICATION: Contact the Sherwin-Williams
Technical Service Department.

DESIGNED TO PERFORM sherwin-williams.com/resin-flooring


RESUWALL FX INTERIOR WALL SYSTEM
SYSTEM GUIDE

CLEANUP DISCLAIMER
Clean up mixing and application equipment immediately The information and recommendations set forth in this
after use. Use toluene or xylene. Observe all fire and document are based upon tests conducted by or on behalf
health precautions when handling or storing solvents. of The Sherwin-Williams Company. Such information and
recommendations set forth herein are subject to change and
SAFETY PRECAUTIONS pertain to the product offered at the time of publication.

Refer to the SDS sheet before use. Published technical data and Consult www.sherwin-williams.com/resin-flooring to obtain
instructions are subject to change without notice. Contact your the most recent Product Data information and Application
Sherwin-Williams representative for additional technical data instructions.
and instructions.
WARRANTY
MATERIAL STORAGE The Sherwin-Williams Company warrants our products to
Store materials in a temperature controlled environment be free of manufacturing defects in accord with applicable
(40°F-90°F) and out of direct sunlight. Keep resins, hardeners, Sherwin-Williams quality control procedures. Liability for
and solvents separated from each other and away from sources products proven defective, if any, is limited to replacement of
of ignition. the defective product or the refund of the purchase price paid
for the defective product as determined by Sherwin-Williams.
MAINTENANCE
Occasional inspection of the installed material and spot repair NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE
can prolong system life. For specific information, contact the BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED, STATUTORY,
Sherwin-Williams Technical Service Department. BY OPERATION OF LAW OR OTHERWISE, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

THE SHERWIN-WILLIAMS DIFFERENCE


Sherwin-Williams High Performance Flooring delivers world-class industry subject matter expertise, unparalleled technical and specification
service, and unmatched regional commercial team support to our customers around the globe.

United States & Canada ©2021 The Sherwin-Williams Company


High Performance Flooring
sherwin-williams.com/resin-flooring PM-279170-57 07/21

You might also like