0% found this document useful (0 votes)
46 views1 page

Single Line 3

The single line diagram shows the electrical layout for a building with power entering from a utility line. It has a kilowatt hour meter, main circuit breaker, grounding, and panelboard distributing power to various lighting, convenience outlet, and appliance circuits.

Uploaded by

kbgainsan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views1 page

Single Line 3

The single line diagram shows the electrical layout for a building with power entering from a utility line. It has a kilowatt hour meter, main circuit breaker, grounding, and panelboard distributing power to various lighting, convenience outlet, and appliance circuits.

Uploaded by

kbgainsan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SINGLE LINE DIAGRAM REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS

RECOMMENDING APPROVAL:

HEAD ARCHITECTURAL SECTION

APPROVED:

BUILDING OFFICIAL
AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
CEBU CITY

DATE

DATE

NORECO 2, 220 V,
SINGLE PHASE LINE RECOMMENDING APPROVAL:

2-30mm² THW wire in 40mm Ø RSC Pipe

CL LAND USE & ZONING


KILOWATT HOUR METER 100 APPROVED:

HEAD DATE
2-30mm² THW wire in 40mm Ø PVC Pipe

RECOMMENDING APPROVAL:
MAIN CIRCUIT BREAKER 100A
100AT/100 AF , 2P
8 mm²
GROUND
BARE COPPER
LINE AND GRADE
APPROVED:

2-30mm² THW wire in 40mm Ø PVC Pipe HEAD DATE

PANELBOARD RECOMMENDING APPROVAL:

100A

LIGHTING SYSTEM C1 C2 LIGHTING SYSTEM


ARCHITECTURAL
15A 15A APPROVED:

HEAD DATE

LIGHTING SYSTEM C3 C4 LIGHTING SYSTEM


15A 15A RECOMMENDING APPROVAL:

CONVENIENCE OUTLET C5 C6 CONVENIENCE OUTLET


20A 20A STRUCTURAL
APPROVED:

HEAD DATE
CONVENIENCE OUTLET C7 C8 RANGE
20A 30A
RECOMMENDING APPROVAL:

REFRIGERATOR C9 C10 WATER HEATER


30A 30A SANITARY
APPROVED:

ACU 2HP C11 C12 ACU 2HP HEAD DATE

30A 30A
RECOMMENDING APPROVAL:

ACU 2HP C13 C14 ACU 3HP


30A 30A
ELECTRICAL
APPROVED:

SPARE C15 C16 SPARE


30A 30A HEAD DATE

RECOMMENDING APPROVAL:

GROUND

8 mm²
BARE COPPER
MECHANICAL
APPROVED:

HEAD DATE

FROM THE OFFICE OF: REG. NO: 123456 PROJECT TITLE: OWNER: SHEET CONTENTS SHEET NO:

PTR: FOR PERMIT AS SHOWN

ENGR. FRANCIS ADRIAN Y. MILABO


BRGY. BANTAYAN, DUMAGUETE CITY
ISSUED ON:
ISSUED AT:
09/09/2023
DGTE CITY
A PROPOSED TWO STOREY RESIDENTIAL BUILDING
BRGY. BANTAYAN, DUMAGUETE CITY
ENGR. FRANCIS ADRIAN Y. MILABO
BRGY. BANTAYAN, DUMAGUETE CITY
DATE: SEPTEMBER 2023
A01
TIN: 123-456-789 DRAWN BY: FRANCIS ADRIAN Y. MILABO 1 8