You are on page 1/ 183

Hitachi Proprietary DKC810I

Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.


INST05-01-10

5. SVP procedure

5.1 INDEX

5.2 New Installation SVP Procedure ............................................................... INST05-02-10


5.2.1 TOD Setting and Set IP Address ....................................................... INST05-02-10
5.2.2 Configuration Information Definition .................................................. INST05-02-80
5.2.2.1 LDEV ID setting procedure when the emulation types of
different systems coexist ............................................................ INST05-02-480
5.2.2.1.1 Coexistence in units of parity group .................................... INST05-02-480
5.2.3 Check Procedure ............................................................................... INST05-02-500
5.2.4 Refer Configuration ........................................................................... INST05-02-540

5.3 Change Configuration SVP Procedure ..................................................... INST05-03-10


5.3.1 Setting up the New Device Structure Information .............................. INST05-03-10
5.3.1.1 System Option ............................................................................ INST05-03-20
5.3.1.2 DCR Configuration ..................................................................... INST05-03-40
5.3.1.3 CVS Configuration ..................................................................... INST05-03-90
5.3.1.4 LUN Management ...................................................................... INST05-03-450
5.3.2 Emulation Type Change .................................................................... INST05-03-900

5.4 Procedure for connecting external servers ............................................... INST05-04-10


5.4.1 Connect SVP by remote desktop ...................................................... INST05-04-10
5.4.2 Configure DNS Setting of SVP .......................................................... INST05-04-30

5.5 Switch the Auto Account Lock Function.................................................... INST05-05-10

INST05-02-10
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-10

5.2 New Installation SVP Procedure


5.2.1 TOD Setting and Set IP Address

[1] TOD Setting (Turn on storage system power before TOD Setting)

1. <Open [Control Panel]>


Select (DR) [Settings] and then [Control Panel]
from [Start].

2. <Open [Date and Time]>


Select (DC) [Date and Time] from [Control
Panel].

INST05-02-10
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-20

3. <Select [Time zone]>


Select (CL) [Change time zone...].

4. <Check the setting of [Time zone]>


Make sure that the setting of [Time zone] is
“(UTC) Coordinated Universal Time”. Then,
press [OK] (CL).

5. <Close [Control Panel]>


Select (DR) [File] and then [Close] from [Control Panel].

6.
Change the mode to [Modify Mode] from [View Mode] (CL).

7.
Select (CL) [Install].

INST05-02-20
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-30

8.
Select (CL) [Set Subsystem Time] in the
‘Install’ window.

9.
Select (CL) [TOD Change] in the ‘Set
Subsystem Time’ window, and then select
(CL) [OK].

10.
Specify the date (year, month and day) and time
(hour, minute and second) and select (CL) [OK].

11.
Close the ‘Install’ window.

In case of New Installation, go to INST02-340 Step (5).

INST05-02-30
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-40

[2] Set IP Address


NOTICE: • The Case where SVP High Reliability kit is installed.
When SVP High Reliability kit is installed, Both Master SVP and Standby
SVP need to be set IP Address.
Firstly set IP Address of Standby SVP.
After completing it, please set the IP Address of Master SVP.
Although “RC = 7ff200” may occur, there is no problem.
Please complete SIM before operation.

1.
Change the mode to [Modify Mode] from [View Mode] (CL).

When SVP is Standby SVP, “The available


maintenance operations are limited due to
lock process failure. If you want to make all
the maintenance operations operable, check
that the communication error has not occurred
between SVP and DKC, and then retry the
operation. If this status is still unrecoverable,
reboot the SVP.” is displayed, select (CL) the
[OK] button.

2.
Select (CL) [Install].

3.
Select (CL) [Set IP address] in the ‘Install’
window.

INST05-02-40
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-50

4. <Change the IP Address>


(1)
Select (CL) [SVP] and setting IP Address and
Subnet Mask of an Internal IP Address.

The case when SVP High Reliability kit is


installed. Check (CL) [Use Duplex SVP], and
check (CL) in the SVP Kind.
* [Master SVP] is checked (CL) when setting to
Master SVP.
* [Standby SVP] is checked (CL) when setting
to Standby SVP.
The SVP High Reliability kit un-setting up
Check (CL) [IPv4] in the Use Internet Protocol
in the case of use IPv4. And enter the IP addresses and subnet masks of the IPv4 of the Master
and Standby SVPs.
Check (CL) [IPv6] in the Use Internet Protocol in the case of use IPv6. And enter the IP
addresses and subnet prefix length of the IPv6 of the Master and Standby SVPs.
Select (CL) [OK] after setting External IP Address.

NOTE: In case of setting Subnet Mask of internal IP Address, the previous address may be
displayed if you set an address that is different than the value of DKC.
If the displayed address is different from what you have set, make the setting again to
match the value of DKC.

The SVP High Reliability kit setting up The SVP High Reliability kit setting up
(Master SVP) (Standby SVP)

INST05-02-50
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-60

(2)
Select (CL) [OK] in response to the
confirmation message “When there are
directions to set the external IP address,
please set the external IP address from the
“Control Panel” of Windows after performing
this operation.”.

(3) <Backup for configuration information>


 The message “Backup processing of
configuration information will start.
Please select the SVP or a Maintenance
PC and insert a media.” is displayed. Set
the Config media to the selected drive and
select (CL) [OK].

 When backup of configuration information is


completed, the message “Please remove the
Config media.” is displayed. Remove the
configuration information media and select (CL)
[OK].

INST05-02-60
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-70

(4)
In response to the message “This will reboot SVP.”, select
(CL) [OK].

Change the IP Address is abnormally terminated if the


message “Failed to change the IP address.” is displayed.
Identify the error cause according to the procedure shown in
“TROUBLE SHOOTING SECTION”.
(Refer to TRBL02-430)

NOTICE: If the remote connection to the Maintenance PC is disconnected during the


operation, reconnect by changed IP address it to continue the operation.
Please perform a remote desktop reconnection after more than five minutes
from pushing down the [OK] button of a [INS1105i] message. (Operation for
connection to SVP, refer to SVP01-60.)

(5)
When a “Use Duplex SVP” or “SVP Kind” of External IP Address is changed, it is necessary
to execute the following operation.
• Setting an external IP Address (Refer to INST03-12-510, 4-12)
• Executing SSVP Reset (Refer to INST03-12-600)

[3] Setting Web Console


Make a setting of the Web Console according to [Web Console] section 1. (WEB01-10)

INST05-02-70
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-80

5.2.2 Configuration Information Definition

CAUTION
This operation is necessary only when a storage system is newly installed. It is not
performed afterward. If it is performed by mistake, a system down or a data loss may be
caused.

1. <Mode Change>
Change the mode to [Initial Setting].
Select “Shift” + “Ctrl” + “I”.

Enter the password and select (CL) [OK].

Select (CL) [OK] in response to the


confirmation message
“<Important CAUTION>
This MODE is INITIAL SETUP MODE. You must not execute NON-DISRUPTIVE
INSTALL and NON-DISRUPTIVE DE-INSTALL!”

Please call Technical Support Division for asking the password.


Select (CL) [Install].

NOTE: The mode changes to [Initial Setting (Unlocked)] when the storage system is in CE
MODE.

2.
Select (CL) [Define Configuration and
Install].

INST05-02-80
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-90

CAUTION
This is a special (exceptional) operation that can cause a serious failure such as a
system down or a data loss if executed in an occasion other than the new storage system
installation, and requires an input of a password. Ask the technical support division about
the appropriateness of the operation, and input the password after getting an approval of
executing the operation.

3.
(1)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
This operation is new installation. If you want
to Non-disruptive Install or Non-disruptive
remove, terminate this procedure by
[CANCEL] button and select INSTALL-
CHANGE CONFIGURATION menu.”.

(2)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
When you continue this operation, finally you
need DKC PS OFF. Are you sure you want to
continue this operation?”.

(3)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
When you continue this operation, customer’s
DATA is LOST. Are you sure you want to
continue this operation?”.

INST05-02-90
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-100

(4)
Select (CL) [OK] in response to the
confirmation message
“<IMPORTANT CAUTION>
External LU information and logical partition
information will be initialized if you continue
this operation. Please restore configuration to
prevent initialization of these data. Are you
sure you want to continue this operation?”.

(5)
Enter the password and select (CL) [OK].
Entering the password is required in this
operation.
Please call Technical Support Division for
asking it.

INST05-02-100
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-110

(6)
Response to the message “This operation
should be in CE mode. Please check the state
of the storage system.
[Yes]: When it is already in CE mode.
[No]: When it is not in CE mode or it is
executed without the jumper.”.
NOTE: Don’t change the number of installed
Hardware (CM/PCBs/etc) except for
powering on the storage system with CEMD Maintenance Jumpers (LOC06-160)
installed.

When [Yes] is selected (CL), go to Step (6)-1.


When [No] is selected (CL), go to Step (7).

(6)-1
Response to the message “The MPBs
displayed below are ones set to CE mode.
Verify that all of the MPBs mounted on the
storage system are displayed.
[MPB set to CE mode]
MPB-nnn MPB-nnn

Unless all of the MPBs are displayed, verify


the state of the storage system.
- Verify the jumper settings.
- Verify that the storage system is turned on.
(Notice that it may take about five minutes
before changing to CE mode after turning the
storage system on, so wait for a few minutes
and retry the operation.)
If no abnormality is found on the storage system, replace the MPB(s) that are not displayed in
this message, and then retry the operation.
Do you want to continue this processing?”.

When [Yes] is selected (CL), go to Step (7). When [No] is selected (CL), go to Step 2.

NOTE: MPB displaying in a message is MPB in the CE mode when this message was
displayed. Unless all of the MPBs are displayed, select (CL) [NO] and start with Step
2 again.

INST05-02-110
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-120

(7)
Select (CL) [OK] in response to the
confirmation message “Installation data of
program product in the Configuration table
will be initialized by this operation. After
finishing this procedure, please set the
product installation again.”.

NOTE: When information of HDP/HDT-VOL implementation or progressing state of quick


format is not included, go to Step 4

NOTICE: When SVP High Reliability kit is installed and IP Address is changed from this
operation.
Set IP Address of Standby SVP. (Refer to INST05-02-40)
After completing it, please set IP Address of Master SVP from this operation.

(8)
Response to the message “The information of
HDP/HDT-VOL implementation or the
progressing status of quick format is included.
When you continue the operation, HDP/HDT-
VOL data or the progressing status of quick
format is initialized.
Do you want to continue this operation?”.

When you continue this operation, select (CL) [Yes].


When [No] is selected (CL), this processing will be stopped. Return to Step 2.

INST05-02-120
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-130

4. <DKC Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

[IP Address]:
The ‘IP Address Configuration’ window
is displayed.
Refer to Step 4-1.
[CHA/DKA/MPB]:
The ‘CHA/DKA/MPB Configuration’
window is displayed.
Refer to Step 4-2.
[Cache]:
The ‘Cache Configuration’ window is displayed.
Refer to Step 4-3.
[System Option]:
The ‘System Option’ window is displayed.
Refer to Step 4-4.

When the setting of all the entry items is completed, select (CL) the [>>Next] button. The
routine goes to Step 4-5.
A selection (CL) of the [Cancel] button completes this operation procedure.

4-1 <IP Address Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

Set the IP address and the subnet mask.

After the setting is completed, select (CL) the


[OK] button.
Return to Step 4.
Select (CL) the [Cancel] button not to reflect
the settings.
Return to Step 4.

INST05-02-130
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-140

4-2 <CHA/DKA/MPB Configuration window>


Set the PCB type following the storage
system configuration information worksheet.

[Change...]:
The ‘CHA/DKA/MPB Define’ window
is displayed. (Refer to Step 4-2-1.)

After setting the items, select (CL) [OK].


(Go back to Step 4.)
Select (CL) [Cancel] not to reflect the settings. (Go back to Step 4)

4-2-1 <CHA/DKA/MPB Define window>


Select PCB types following the storage
system configuration information worksheet.
And then select (CL) [OK].
(Go back to Step 4-2.)

INST05-02-140
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-150

4-3 <Cache Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

Set the cache capacities/SM function.


[Cache Size]:
The ‘Cache Size Define’ window is
displayed. (Refer to Step 4-3-1.)
[BKM]:
The ‘BKM Define’ window is
displayed. (Refer to Step 4-3-2.)
[SM function]:
The ‘SM function Define’ window is displayed. (Refer to Step 4-3-3.)
[DCR Change]:
The ‘DCR Available Size Define’ window is displayed. (Refer to Step 4-3-4.)
[Set CLPR]:
The ‘CLPR Define’ window is displayed. (Refer to Step 4-3-5.)

After the setting is completed, select (CL) the [OK] button. (Return to Step 4.)
Select (CL) the [Cancel] button not to reflect the settings. (Return to Step 4.)

4-3-1 <Cache Size Define window>


Set the Cache Size in the ‘Cache Size Define’
window, select (CL) [OK]. (Return to Step 4-3.)

4-3-2 <BKM Define window>


Set the BKM function in the ‘BKM Define’ window,
select (CL) the [OK] button.
(Return to Step 4-3.)

INST05-02-150
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-160

4-3-3 <SM function Define window>


Set the SM function in the ‘SM function
Define’ window, select (CL) the [OK] button.
(Return to Step 4-3.)

4-3-4 <DCR Available Size Define window>


Set the DCR available size in the ‘DCR Available Size
Define’ window and select (CL) the [OK] button.
(Return to Step 4-3.)

4-3-5 <CLPR Define window>


Set the Cache Size/DCR available
Size/Number of extent in the ‘CLPR Define’
window and select (CL) the [OK] button.
(Return to Step 4-3.)

INST05-02-160
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-170

4-4 <System Option window>


Set the configuration information following the storage
system configuration information worksheet.

Set the system option information.

If select (CL) [WR.Trough], ‘Synchronous Destage Mode


Define’ window is displayed. (Refer to Step 4-4-1.)

After setting all the items, select (CL) the [OK] button.
(Return to Step 4.)
Select (CL) the [Cancel] button not to reflect the settings.
(Return to Step 4.)

4-4-1 <Synchronous Destage Mode Define Window>


Set the configuration information following the system
configuration information worksheet.

After setting all the items, select (CL) [OK]. (Return to


Step 4-4.)

INST05-02-170
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-180

4-5 <HUBBOX message>


Select (CL) [OK] in response to the
confirmation message
“This storage system needs the
HUBBOX(s)(HUBBOX-nn). Please install
the HUBBOX(s)(HUBBOX-nn).”
(Go to Step 5.)
NOTE: This windows is displayed when
storage system needs the HUBBOX.

INST05-02-180
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-190

5. <CHA Setting>
According to the types of setting CHA, windows are displayed.

Setting the Fibre: Go to Step 5-1.


Setting the MFibre: Go to Step 5-2.

When the setting of all CHAs is completed, go to Step 6.

5-1 <Fibre PCB Configuration window>


[I/T...]:
Makes a setting of the ‘Target / RCU
Target / Initiator / External’. (Refer to
Step 5-1-1.)
[Speed...]:
Sets the channel speed. (Refer to Step 5-
1-2.)

After the setting is completed, select (CL) the


[>>Next] button for setting the next CHA.
Return to Step 5.

When the [Before<<] button is selected (CL), the window is returned to the preceding window.

INST05-02-190
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-200

5-1-1 <Initiator/Target Define window>


Make a setting of the ‘Target / RCU Target / Initiator /
External’ and select (CL) the [OK] button. (Return to
Step 5-1.)
Select (CL) the [Cancel] button not to reflect the
settings. (Return to Step 5-1.)

5-1-2 <Fibre Channel Speed Define window>


Set the channel speed and select (CL) the [OK]
button. (Return to Step 5-1.)
Select (CL) the [Cancel] button not to reflect the
settings. (Return to Step 5-1.)

INST05-02-200
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-210

5-2 <Mainframe PCB Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

[FNP...]: Sets the HTP/FNP. (Refer to


Step 5-2-1.)
[CU Num...]: Sets the valid CU number.
(Refer to Step 5-2-2.)
[Emulation...]: Sets the DKC Emulation.
(Refer to Step 5-2-3.)

After the setting is completed, select (CL) the


[>>Next] button.
Go to Step 5-2-4.

When the [Before<<] button is selected (CL), the window is returned to the preceding window.

NOTE: The setting of “CU Number” cannot be done for the definition that crosses 16KLDEV
boundary (00:00-00:3F/00:40-00:7F/00:80-00:BF/00:C0-00:FE) for per two ports.
When the definition that crosses 16KLDEV boundary is done, it is defined for per two
ports.

5-2-1 <HTP/FNP Define window>


Set the HTP/FNP and select (CL) the [OK] button.
(Return to Step 5-2.)
Select (CL) the [Cancel] button not to reflect the
settings. (Return to Step 5-2.)

INST05-02-210
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-220

5-2-2 <CU Number Define window>


Set the valid LDKC/CU number and select (CL) the [OK]
button. (Return to Step 5-2.)
Select (CL) the [Cancel] button not to reflect the settings.
(Return to Step 5-2.)

5-2-3 <DKC Emulation window>


Set the DKC Emulation and select (CL) the
[OK] button. (Return to Step 5-2.)
Select (CL) the [Cancel] button not to reflect
the settings. (Return to Step 5-2.)

5-2-4 <SVP message>


Select (CL) [OK] for setting the next CHA in
response to the confirmation message “Data
will be lost from the logical device if you
connect the interface cable to an incorrect
port. Be sure to connect the cable to the
correct port.”.
NOTE: This windows is displayed when
Serial (8S) and Mfibre (8M) Channel is installed.

INST05-02-220
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-230

6. <DKU Equipment Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

Set the DKU equipment (Module0/Module1)


pattern.

When you want to set the DKU type, select


(CL) [DKU Kind].
Go to Step 6-1.

After the setting is completed, select (CL) the


[>>Next] button. (Go to Step 7.)
When the [Before<<] button is selected (CL), the window is returned to the preceding window.
This operation is completed when the [Cancel] button is selected (CL).

6-1 <DKU Kind Define window>


Set DKU Kind select (CL) the [OK] button.
Return to Step 6.

INST05-02-230
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-240

7. <Physical Device Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

[Set...]:
Defines the parity group(s) or the spare
disk in the specified B4. (Go to Step 7-
1.)
[Clear]
Cancels the setting of the B4.

After setting all the items, select (CL) the [>>Next] button. (Go to Step 8.)
When the [Before<<] button is selected, return to Step 6.
This operation is completed when the [Cancel] button is selected (CL).

INST05-02-240
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-250

7-1 <Parity Group Configuration window>


Set the configuration information following
the storage system configuration information
worksheet.

[Group...]: Sets the parity group(s).


(Refer to Step 7-1-1.)
[Spare...]: Sets the spare drive.
(Refer to Step 7-1-2.)
[Delete]: Deletes the item.

Grp*: A parity group for which the RAID


connection has been set

NOTE: When you want to set the spare drive, make the setting of it first.

After setting all the items, select (CL) the [OK] button. Return to Step 7.

INST05-02-250
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-260

7-1-1 <Parity Group window>


Set the RAID Level, Drive Type, and Number
of Group.

Then select (CL) the [OK] button. (Return to


Step 7-1.)
Select (CL) the [Cancel] button not to reflect
the settings. (Return to Step 7-1.)

The settable disk types differ depending on


the definition of the Back-end fibre (DKA-
HDD) transfer rate.

7-1-2 <Spare window>


Set the Drive Type and Number of Spare.

Then select (CL) the [OK] button. (Return to


Step 7-1.)
Select (CL) the [Cancel] button not to reflect
the settings. (Return to Step 7-1.)

The settable disk types differ depending on


the definition of the Back-end fibre (DKA-
HDD) transfer rate.

INST05-02-260
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-270

8. <Define Device Emulation>


After setting up all items corresponding to 8-1 to 8-3 for definition of Device Emulation, select
(CL) [>>Next].
Selecting (CL) [Before<<] returns you to the previous window.
• If defining Device Emulation, go to Step 8-1.
• If setting RAID concatenation, go to Step 8-2.
• If defining of Customized Volume Size (CVS), go to Step 8-3.

8-1 <Define Device Emulation>


(1)
In the ‘Device Emulation Configuration’
window, select (CL) the parity group, and
then select (CL) the [Set...] button. Go to Item
(2).

When canceling the emulation, go to Step 8-1


(3).
After the setting is completed, select (CL) the
[>>Next] button.

This operation is completed when the


[Cancel] button is selected (CL).

(CVS): A parity group for which the CVS has been set
Grp*: A parity group for which the RAID connection has been set

(2)
After setting all items in the ‘Device Emulation
Type Define’ window, select (CL) the [OK] button.
(Return to Step 8-1 (1).)
Select (CL) the [Cancel] button not to reflect the
settings. (Return to Step 8-1 (1).)
NOTE: OPEN-V is a recommended OPEN volume.
To set other than OPEN-V, please select
“Except OPEN-V”.
NOTE: “0” can be set to the value of Number of
LDEVs for all the emulation types.
If you don’t know the LDEV size you will
use, set “0”. You can save time by setting “0” because LDEV format will not run.
When you set “0”, please make LDEVs later using the CVS function.
NOTE: If 3390-A is selected, a 3390-A volume whose capacity is as large as that of standard
capacity of the specified emulation type can be created by specifying (3390-3 size),
(3390-9 size), (3390-L size), or (3390-M size) in the “Number of LDEVs”. If a parity
group consists of drives with 1TB or larger is specified, only (3390-M size) can be
selected in the “Number of LDEVs”.

INST05-02-270
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-280

(3) <Canceling emulation>


Select (CL) the parity group and select (CL)
the [Clear] button.
This operation is completed when the
[Cancel] button is selected (CL).

(CVS): A parity group for which the CVS has


been set
Grp*: A parity group for which the RAID
connection has been set

8-2 <Setting RAID concatenation>


(1)
After setting the LDEV emulation type and a
number of LDEVs, select (CL) the
[Concatenate...].
This operation is terminated when the
[Cancel] is selected (CL).

(CVS): A parity group where CVS is


installed.
Grp*: A parity group where RAID
Concatenation is installed.

(2)
Parity groups to which the RAID
concatenation can be applied are displayed in
the Parity group List.
Select (CL) parity groups to which you want
to apply the RAID concatenation and press
(CL) the [>>] button.

INST05-02-280
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-290

(3)
The selected parity groups are registered in
the Concatenate Parity group List. Then press
(CL) the [Concatenate] button.
NOTE: The [Concatenate] button cannot be
pressed if the concatenation does not
meet a condition of the RAID
concatenation. Adjust the number of
the parity groups in the Concatenate
Parity group List.

(4)
When the RAID concatenation is completed,
“(Concatenation)” is displayed in the Parity
group List. Selecting the “(Concatenation)”
displays the concatenated parity groups in the
Concatenation List. Pressing the [Clear]
button cancels the RAID concatenation.

(5)
When all the settings of the RAID concatenation are completed, press (CL) the [OK] button.
Select (CL) the [Cancel] button not to reflect the settings. (Return to Step 8-2 (1))

INST05-02-290
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-300

8-3 <Defining of Customized Volume Size (CVS)>


(1)
Select (CL) a parity group for which the
LDEV emulation type and the number of
LDEVs have been set on the ‘Device
Emulation Configuration’ window and select
(CL) [Detail...].
This procedure is terminated by selecting
(CL) [Cancel].

(CVS): A parity group where CVS is


installed.
• When you select a parity group other than
OPEN-V, go to Step (2).
• When you select OPEN-V, go to Step (3).

Grp*: A parity group where RAID Concatenation is installed.


asst.: A parity group where the Make Volume process cannot be performed because it
includes the LDEV in which Path/pool-VOL is set.
NOTE: Even if a parity group includes the LDEV in which the journal volume is set,
“+” is not displayed.

INST05-02-300
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-310

(2) <Definition other than OPEN-V>


A volume other than OPEN-V can be defined
in the “Customized Volume Size Define”
window.
• Delete of the Volume
A volume can be deleted by selecting (CL)
the volume from the LDEV list box and
selecting (CL) [Delete].
• Add of the Volume
A volume can be added by entering the
LDEV emulation type and the user size
(Mbyte/Blocks or Cylinder) of the customized volume (CV) and selecting [Add].
(It can be added in the optional space “empty” by selecting (CL) “empty” from the LDEV list
box.)
The two or more CVs can be registered when the operation above is performed repeatedly.

The boundary correction existence is specifiable with “Offset Boundary”.


(When a volume for mainframe host is selected, it is not possible to select it.)

Adding or deleting operation can be done for any number of times. The last setting is reflected
by selecting (CL) [OK].

NOTE: The two or more volumes can be selected and deleted.

The routine returns to the preceding window by selecting (CL) [Cancel].


The routine returns to the preceding window and the change is reflected by selecting (CL)
[OK].

INST05-02-310
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-320

(3) <Definition of OPEN-V>


OPEN-V can be defined in the “Variable
Volume Size Define” window.
• Delete of the Volume
The volume can be deleted by selecting
(CL) [Delete] in the state (CL) of selecting
(CL) the volume in the LDEV list box.
All the volumes in the LDEV list box can be
deleted by selecting (CL) [Clear].
• Add of the Volume
It can be added by selecting (CL) Variable Volume Size from the status “select (CL)
‘empty’” or “no selection” in the LDEV list box and selecting (CL) [Add].

Adding or deleting operation can be done for any number of times. The last setting is reflected
by selecting (CL) [OK].

NOTE: The two or more volumes can be selected and deleted.

• Variable Volume Size


“Specify size & number” : Defines the specified number of the specified user size.
• Offset Boundary : The boundary correction existence is specified.
• Capacity Unit
“MByte” : Makes data displayed or entered by [MByte].
“Cylinder” : Makes data displayed or entered by the [Cylinder].
“Blocks” : Makes data displayed or entered by the [Blocks].
• asst. : When Path/pool-VOL is defined, “+” is displayed.
[Clear] : Deletes all the volumes.
[Delete] : Deletes all the selected volumes.
[Add] : Adds volumes.
[Cancel] : Invalidates the setting, and returns to the preceding window.
The routine returns to Step (1).
[OK] : Confirms the setting, and returns to the preceding window.
The routine returns to Step (1).

INST05-02-320
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-330

9. <Define LDEV ID>


After setting up all items, select (CL) [>>Next]. Selecting (CL) [Before<<] returns you to the
previous screen.

9-1 <Definition Screen for LDEV ID>


Select (CL) the parity group to be defined and
select (CL) a function from the [LDEV ID]
list box.
[Linear...]:
LDEV ID is assigned to LDEV in the
order of parity group. Refer to Step 9-3.
[Disperse...]:
LDEV ID is assigned discretely in the
order of parity group. Refer to Step 9-3.
[Detail...]:
A screen to define LDEV in detail is
displayed. Refer to Step 9-2.
[Clear]:
Select (CL) [Clear] to delete.

Status: Status of LDEV ID.


 “Complete” : LDEV ID is assigned.
 “-------” : LDEV ID is not assigned.
 “Error” : Invalid LDEV ID is assigned.
This procedure is terminated by selecting (CL) [Cancel].

INST05-02-330
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-340

9-2 <Detailed Definition Screen for LDEV ID>


LDEV ID is defined in detail for each LDEV
in the parity group.
Select (CL) [LEDV] from the list box and
select (CL) [Change...].
The screen for LDEV ID input is displayed.
NOTE: In the case of a RAID Concatenation
Group, LDEV of the parity group
selected by the “Grp List” is
displayed.

9-3 <Input LDEV ID>


Select LDKC in the LDKC pull down menu.
Select CU in the CU pull down menu.
The status of usage of ID in the CU is displayed in
the LDEV ID panel.
White disk of panel: not used
Black disk of panel: using
Input LDEV ID you want to set or head LDEV ID
in the ID Edit box.
After setting, select (CL) [OK]. Return to the
preceding window.
NOTE: The definition range (terminal) is decided
with LDEV Range.
For example, if LEDV Range is defined as
7F, LDEV ID is assigned only within the range of 00 to 7F.

INST05-02-340
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-350

10. <SSID Configuration window>


Set the SSID and the SSID boundary type.
[SS ID...]: The ‘SSID Define’ window is displayed.
(Go to Step 10-1.)
[Boundary]: The ‘SSID Boundary Define’ window is
displayed. (Go to Step 10-2.)

After the setting is completed, select (CL) the


[>>Next] button.
This operation is completed when the [Cancel] button
is selected (CL).

10-1
Set the SSID and select (CL) the [OK] button. (Return
to Step 10.)

10-2 <SSID Boundary Define window>


Set the boundary of the SSID and select (CL) the [OK]
button. (Return to Step 10.)

INST05-02-350
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-360

11. <Defining DCR>


(1)
Select (CL) a parity group having LDEV(s)
for which the DCR is to be set on the “DCR
Configuration” screen and press (CL) the
[Detail...] button.

Total cache memory size which DCR area use


is displayed.

If the selected parity group has a DCR area,


the BIND size and to PRIO size are displayed
under the “DCR Configuration” screen.

Go to Step (6) to delete a parity group.

After setting above, select (CL) [>>Next].

This procedure is terminated by selecting (CL) [Cancel].

INST05-02-360
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-370

(2)
Select (CL) an LDEV where the DCR is to be set on the “DCR Detail (Parity Group)” screen
and press (CL) the [Detail...] button.
If the selected LDEV has a DCR area, the BIND size and the PRIO size are displayed under
the “DCR Detail (Parity Group)” screen.

(For open system) (For Mainframe system)

(3)
Confirm the LDEV size and the number of
slots allowed to be set for each type on the
“DCR Detail (Logical Device)” screen. Press
(CL) the [Set...] button to set the DCR area.

INST05-02-370
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-380

(4)
Enter the type, starting cylinder number, starting head number, ending cylinder number, and
ending head number (for Mainframe system. Refer to the screen on the right.) or the type,
starting LBA, and ending LBA (for open system. Refer to the screen on the left.) on the “DCR
Define” screen and select (CL) [OK].
For open system, all items are allowed to be set.

(For open system) (For Mainframe system)

(5)
When the screen is returned to the “DCR Detail (Logical Device)” screen, the entrance result is
displayed.

(For open system) (For Mainframe system)

INST05-02-380
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-390

(6)
When an item in the list box is selected (CL) and the [Delete] button is pressed (CL) on the
“DCR Detail (Logical Device)” screen, the DCR setting is deleted. When the setting is
completed, press (CL) [OK].

(For open system) (For Mainframe system)

(7)
If you want to set other LDEV(s) in the parity group which you selected, repeat steps (2) to (6)
for the LDEV(s).

(8)
If you want to set other LDEV(s) in other parity group, repeat steps (1) to (6) for the LDEV(s).

INST05-02-390
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-400

12. <Define Auto LDEV Assignment and Management MPB>


Set the Auto LDEV Assignment and
Management MPB.

[Change]:
The ‘Auto LDEV Assignment Define’
window is displayed.
(Refer to Step 12-1.)

[Change MPB]:
The ‘Management MPB Define’ window
is displayed.
(Refer to Step 12-2.)

When the setting of all the entry items is


completed, select (CL) the [>>Next] button.
(The routine goes to Step 13)

12-1 <Define Auto LDEV Assignment>


Define Auto LDEV Assignment and select
(CL) [OK].
Go back to Step 12.

Select (CL) [Cancel] not to reflect the setting.


Go back to Step 12.

12-2 <Define Management MPB>


Define Management MPB and select (CL) [OK].
Go back to Step 12.

Select (CL) [Cancel] not to reflect the setting.


Go back to Step 12.

INST05-02-400
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-410

13. <Define Battery Life Warning SIM>


Select (CL) [Set...] applying the check to
[Battery Life Warning SIM] and select (CL)
the target CM Battery.
(Go to Step 13-1.)

Make sure that the all input items are correct


and select (CL) [OK].
(Go to Step 14.)

NOTE: If the date is displayed as


“****/**/**”, follow Step 13-1 to set
the date.

13-1 <Define Battery Life Warning SIM>


Select (CL) [OK] after inputting the remainder days
until Warning SIM is reported.
(Return to Step 13.)

NOTE: After executing the periodical exchange of


a battery, set 33 month (990 days).
NOTE: Default value is 33 month (990 days), which is 3 month earlier than the lifetime of a
battery (3 years).
Determine the number of days remained based on your maintenance plan.
NOTE: The input ranges of “Remained Battery life” are from 1 to 3650. Please set [Battery
Life Warning SIM] of Step 13 to check off when not reporting on Warning SIM.

INST05-02-410
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-420

14. <LUN Management Screen>


When is equipmented Open PCB(s), LUN
Management dialog to be displayed.

After setting LUN, and close the dialog.


For the setting of LUN, see section 5.3.1.4
LUN Management (INST05-03-450).

15. <Install configuration information>


(1)
Select (CL) [Yes] in response to the
confirmation message “Are you sure you
want to install the defined configuration?”.
Selecting (CL) [No] cancels the configuration
change processing and terminates the
installation procedure.

(2)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
When you continue this operation, finally you
need DKC PS OFF. Are you sure you want to
continue this operation?”.

(3)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
When you continue this operation, customer’s
DATA is LOST. Are you sure you want to
continue this operation?”.

INST05-02-420
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-430

(4)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
When you continue this operation,
configuration data will be changed. Are you
sure you want to continue this operation?”.

(5)
Select (CL) [OK] in response to the
confirmation message
“<Important CAUTION>
When you select [OK] button, you can’t
cancel this operation. Are you sure you want
to continue this operation?
If you terminate this operation by some
forcible method, the storage system be in
UNRECOVERABLE SERIOUSLY DAMAGE.”.

(6)
Select (CL) [OK] in response to the confirmation
message
“<Important CAUTION>
You must not RE-BOOT SVP(PC).”.

16. <Compressing of the configuration information>


The configuration information is compressed.
The dialog of Config Compressing... is
displayed.
After the compressing is completed, go to
Step 18.
NOTE: However, on page INST05-02-100 (6), it advances to Step 17 when [No] is selected
(CL).

INST05-02-430
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-440

17.
Select (CL) [OK] in response to the message
“Turn off the storage system. Make sure that
PS-ON LED at DKC-PANEL is off, and then
turn on the storage system. After the
operation has completed, and then select
[OK].”.

17-1
“Wait... (Approx. 5 minutes)” is displayed.

When there is MPB which is not CE mode, go to


Step 17-2.
When there is not MPB which is not CE mode, go to
Step 18.

17-2
Response to the message “There is one or
more MPBs that are not set to CE mode.
(MPB-nnn MPB-nnn)

- Verify that the storage system is turned on.


(Verify the CE mode again. Changing to CE
mode may take about 5 to 25 minutes after
turning the storage system on.)
If no abnormality is found on the storage
system, replace the MPB(s) specified in this
message, and then retry the operation.
Do you want to continue this processing?
[Yes]: Verifying CE mode again.
[No]: Stopping this processing.”
NOTE: The time required to change to CE mode after turning the storage system ON varies
depending on cache size. When a cache PCB with the maximum size (524,288 MB) is
mounted, changing to CE mode may take up to 25 minutes.

When [Yes] is selected (CL), Verifying of CE mode again. When there is not MPB which is
not CE mode, go to Step 18. When there is MPB which is not CE mode, this message is
displayed again.
When [No] is selected (CL), go to Step 2.

INST05-02-440
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-450

18. <Download Objects window>


If you want to download micro-programs, please
select (CL) [All Microprograms], and select (CL)
[OK].

19. <Configuration information transfer>


The configuration information is forwarded.
After the forward is completed, go to Step 20.
Select (CL) [Detail]. Go to Step 19-1.

19-1
Details of transfer situation are confirmed on Detail
Status window.
When you close the ‘Detail Status’ window, select
(CL) [Close].

INST05-02-450
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-460

20.
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

21.
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media, and
then select (CL) [OK].

22.
“Reconstructing device information...” is displayed.

INST05-02-460
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-470

23.
Select (CL) [OK] in response to the message
“Turn off the storage system. Make sure that
PS-ON LED at DKC-PANEL is off, and then
turn on the storage system. When the jumper
of CE mode has been inserted, pull out the
jumper of CE mode before turning on the
storage system. Make sure that PS-ON LED
at DKC-PANEL is on, and then select [OK].”.

24.
Select (CL) [OK] in response to “This will reboot SVP.”.

INST05-02-470
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-480

5.2.2.1 LDEV ID setting procedure when the emulation types of different systems coexist
5.2.2.1.1 Coexistence in units of parity group
The LDEV ID setting procedure is explained using an example of a case in which both the 3390
system LDEV and OPEN system LDEV are set in the same storage system. This example shows the
ID setting procedure when the B4-1/B4-2 is fully equipped with RAID5 (3D+1P), and the B4-1 and
the B4-2 are defined as the 3390-3/OPEN-3 and the 3390-9/OPEN-3 respectively. Since systems
other than the 3390 system cannot coexist in the parity group, the ID can be defined in this
procedure.

1.
Select only the parity group for which the
3390 system emulation type has been defined
and then select (CL) [Linear...] or
[Disperse...].

2.
Input the LDEV ID and select (CL) [OK]. In
the example, the case selected [Disperse...] is
displayed.

INST05-02-480
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-490

3.
Select only the parity group for which the OPEN
system emulation type has been set and then select
(CL) [Linear...] or [Disperse...].

4.
Input the LDEV ID. In this case, take care not to make
a coexistence occur in the block. In the example, 0:a0
and the subsequent are unused blocks. Therefore, input
a0. After the setting is completed, select (CL) [OK].
NOTE: The definition range (terminal) is decided
with LDEV Range.
For example, if LEDV Range is defined as
7F, LDEV ID is assigned only within the
range of 00 to 7F.

5.
Setting is completed.

Needless to say, the setting sequence of steps (1) and (3) may reversed.
If emulation types of different systems are selected at the same time, the guarding function
works to prevent the setting by making the Linear and Dispense buttons unselect able.

INST05-02-490
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-500

5.2.3 Check Procedure

CAUTION
This operation is necessary only when a storage system is newly installed. It is not
performed afterward. If it is performed by mistake, a system down or a data loss may be
caused.

1. <Execute Power-on CUDG>


Perform the power-on procedure from the DKCPANEL.
(See INST03-14-10)
Power-on CUDG is automatically executed on the DKC logic circuitry.
If an error occurs, SIM Log, SSB Log has logging.
(See SVP02-02-10)

2. <Execute DKU Path inline test>


Perform DKU Path inline tests on all DKAs installed during the new installation procedure to
check the validity of the drives.
Please carry out A3 routine after carrying out A0 routine.
See DIAGNOSIS SECTION for the test procedure. (DIAG04-130) (*1)
NOTE: Before carrying out the DKU Path inline test, switch the current application to the
program manager and have the SVP initial screen (which is shown in the right figure)
displayed.

3. <Check storage system status and all MPs micro-version>


Check the storage system Status and all MPs micro-version.
(See SVP03-01-10 and SVP03-07-10)

*1: When wrong connection of the DEV I/F CABLE is detected by DKU Path inline, please
recover according to following operation.
(1) PS/OFF
(2) Fix the DEV I/F CABLE connection
(3) PS/ON and execute DKU Path inline again

INST05-02-500
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-510

4. <Format LDEV>

CAUTION
This is a special (exceptional) operation that can cause a serious failure such as a
system down or a data loss if executed in an occasion other the new storage system
installation, and requires an input of a password. Ask the technical support division about
the appropriateness of the operation, and input the password after getting an approval of
executing the operation.

Change the mode to [Initial Setting].


Select [Shift] + [Ctrl] + [I].
Enter the password and select (CL) [OK].
Please call Technical Support Division for asking the password.

Select (CL) [OK] in response to the


confirmation message “<Important
CAUTION> THIS IS INITIAL SETUP
MODE. WHILE RUNNING THIS MODE,
DO NOT EXECUTE INSTALLATION OR
REMOVAL THAT MAY CAUSE
DISRUPTIONS.”.

Select (CL) [Install].

Select (CL) [Logical Device Format].


NOTE: Execute Format Logical Device after
confirming all Logical Device is
blocked.

4-1
Select (CL) [Yes] in response to “This
process will format all logical devices. Are
you sure you want to continue this process?”.

INST05-02-510
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-520

4-2
CAUTION
This is a special (exceptional) operation that can cause a serious failure such as a
system down or a data loss if executed in an occasion other than the new storage
system installation, and requires an input of a password. Ask the technical support
division about the appropriateness of the operation, and input the password after getting
an approval of executing the operation.

Enter the password and select [OK] (CL).


Password is needed for this operation.
Please call Technical Support Division to
obtain a password and authorization.

4-3
When LDEV Formatting is complete, “Formatting
logical devices...” shown in the right figure
disappears and “Formatting was finished.” is
displayed.

4-4
Select (CL) [OK] in response to “Formatting was
finished.”.

LDEV formatting is abnormally terminated if the message


“Formatting logical devices rejected by DKC.” or
“Formatting the logical device is failed.” is displayed.
Identify the error cause according to the procedure shown
in “TROUBLE SHOOTING SECTION”.

INST05-02-520
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-530

4-5 <Check logical device status>


Check if Logical Devices are normal by with referring to the ‘Logical Device Status’ display.

5. <Check storage system status>


Check if all parts are normal by referring to ‘Maintenance’.

6. <Check system interlock operation>


Start the test program from the host to check for normal storage system’s interlocked operation
with the host.

7. <Delete error log>


Power ON/OFF the storage system to make sure that the storage system starts normally
(neither ALARM nor MESSAGE indicators should light).

Delete all error log information from the SVP and transfer the storage system to the user.
See SVP02-03-10.

Go to Step INST02-380.

INST05-02-530
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-540

5.2.4 Refer Configuration

1. <Start [Install]>
Select (CL) [Install] from ‘SVP’.

2.
Select (CL) [Refer Configuration].

3. <DKC Configuration window>


[IP Address]:
The ‘IP Address Configuration’ window
is displayed.
Refer to Step 3-1.
[CHA/DKA/MPB]:
The ‘CHA/DKA/MPB’ window is
displayed.
Refer to Step 3-4.
[Cache]:
The ‘Cache Configuration’ window is
displayed.
Refer to Step 3-2.
[System Option]:
The ‘System Option’ window is displayed.
Refer to Step 3-3.

When the [>>Next] button is selected (CL), go to Step 4.


This procedure is completed when the [Cancel] button is selected (CL).

INST05-02-540
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-550

3-1 <IP Address Configuration window>


Select (CL) the [OK] button. (Return to Step
3.)

3-2 <Cache Configuration window>


Select (CL) the [OK] button. (Return to Step
3.)

Refer to INST01-80 for the SVP screen


display and the conversion of the option type
names.

INST05-02-550
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-560

3-3 <System Option window>


When the [Mode...] is selected (CL), the ‘Mode’
window is displayed. (Refer to Step 3-3-1.)

When the [WR.Trough] is selected (CL), the


‘Synchronous Destage Mode Define’ window is
displayed. (Refer to Step 3-3-2.)

Selecting (CL) [OK] returns to Step 3.

3-3-1 <Mode window>


By setting “Range of Mode,” the range shown
in “Mode Configuration” is changed

Select (CL) the [OK] button. (Return to Step


3-3.)

INST05-02-560
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-570

3-3-2 <Synchronous Destage Mode Define window>


Destage Status of LDEVs to the specified LDKC/CV is
displayed.
Select (CL) the [OK] button. (Return to Step 3-3.)

3-4 <CHA/DKA/MPB Configuration>


Selecting (CL) [OK]. (Return to Step 3.)

INST05-02-570
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-580

4. <CHA Setting>
According to the types of setting CHA, windows are displayed.

Setting the Fibre: Go to Step 4-1.


Setting the MFibre: Go to Step 4-2.

When the setting of all CHAs is completed, go to Step 5.

4-1 <Fibre PCB Configuration window>


After checking the display, select (CL) the
[>>Next] button.
Return to Step 4.

When the [Before<<] button is selected (CL),


the window is returned to the preceding
window.

4-2 <Mainframe PCB Configuration window>


After checking the display, select (CL) the
[>>Next] button.
Return to Step 4.

When the [Before<<] button is selected (CL),


the window is returned to the preceding
window.

INST05-02-580
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-590

5. <DKU Equipment Configuration window>


The DKU equipment pattern is displayed.
Select (CL) the [>>Next] button. (Go to Step
6.)
This operation is completed when the
[Cancel] button is selected (CL).

6. <Physical Device Configuration window>


[Detail...]: Refers to details of parity
group(s) or the spare drive in the
B4.
(Go to Step 6-1.)
Select (CL) the [>>Next] button. (Go to Step
7.)
This operation is completed when the
[Cancel] button is selected (CL).

6-1 <Parity Group Configuration window>


Select (CL) the [OK] button. (Return to Step 6.)

INST05-02-590
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-600

7. <Setting device emulation>


The ‘Device Emulation Configuration’
window is displayed.
Select (CL) the parity group and select (CL)
the [Detail...] button. (Go to Step 7-1.)
Select (CL) the [Concatenate...] button. (Go
to Step 7-2.)

Select (CL) the [>>Next] button. (Go to Step


8.)

This operation is completed when the


[Cancel] button is selected (CL).
(CVS): A parity group for which the CVS has been set
Grp*: A parity group for which the RAID connection has been set

INST05-02-600
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-610

7-1
7-1-1 <Customized Volume Size Define>
Customized Volume Size Define is displayed.
Select (CL) [OK]. Return to Step 7 or 7-1.

7-1-2 <Variable Volume Size Define window>


The ‘Variable Volume Size Define’ window
is displayed.
• Offset Boundary :
The boundary correction
existence is specified.
• Capacity Unit
“MByte” : Makes data displayed by the
MByte.
“Cylinder” : Makes data displayed by the
cylinder.
“Blocks” : Makes data displayed by the Blocks.
• asst. : When Path/pool-VOL is defined, “+” is displayed.
NOTE: Even if the journal volume is defined, “+” is not displayed.
[Cancel] : Invalidates the setting and makes the preceding window return. Return to Step
7 or 7-1.
[OK] : Fixes the setting and makes the preceding window return. Return to Step 7 or
7-1.

INST05-02-610
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-620

7-2 <RAID Concatenation Configuration window>


The ‘RAID Concatenation Configuration’
window is displayed.
When the “(Concatenation)” displayed in the
Parity group List is selected (CL), parity
groups that have been concatenated are
displayed in the Concatenation List.

Select (CL) the [OK]. Return to Step 7.

8. <Logical Device ID Configuration window>


Logical Device ID Configuration is displayed.
Select (CL) a parity group and select (CL)
[Detail...]. Go to Step 8-1.
Select (CL) [>> Next]. Go to Step 9.
This procedure is terminated by selecting
(CL) [Cancel].
Grp*: The top parity group where RAID
Concatenation is installed.
Status: Status of LDEV ID.
 “Complete” : LDEV ID is assigned.
 “-------” : LDEV ID is not assigned.
 “Error” : Invalid LDEV ID is
assigned.

INST05-02-620
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-630

8-1
Logical Device ID Detail is displayed.
Select (CL) [ID...]. Go to Step 8-2.
Select (CL) [OK]. Return to Step 8.
NOTE: In the case of a RAID Concatenation
Group, LDEV of the parity group
selected by the “Grp List” is
displayed.

8-2
The status of usage of ID in the specified
LDKC/CU is displayed in the LDEV ID panel.
Select (CL) [OK] or [Cancel]. Return to Step 8-1.

9. <Set SSID>
SSID Configuration is displayed.
Select (CL) [>> Next]. Go to Step 10.
This procedure is terminated by selecting (CL)
[Cancel].

INST05-02-630
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-640

10. <DCR Configuration windows>


When the parity group is selected (CL), and
then the [Detail...] button is selected (CL), go
to Step 10-1.
Select (CL) the [>>Next] button.
This operation is completed when the
[Cancel] button is selected (CL).

10-1 <DCR detail (Parity group) window>


DCR detail (Parity group) is displayed.
Select (CL) an LDEV and select [Detail...]. Go to Step 10-2.
Select (CL) [OK]. Return to Step 10.

(For open system) (For Mainframe system)

10-2 <DCR detail (Logical device) window>


DCR detail (Logical device) is displayed.
Select (CL) [OK]. Return to Step 10-1.

(For open system) (For Mainframe system)

INST05-02-640
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-02-650

11. <LDEV Management MPB Configuration window>


Auto LDEV Assignment and Management
MPB is displayed.
Select (CL) [>>Next]. Go to Step 12.

12. <LUN Management Screen>


When is equipmented Open PCB(s), LUN
Management dialog to be displayed.

After setting LUN, and close the dialog.


For the setting of LUN, see section 5.3.1.4
LUN Management (INST05-03-450).

13.
Select (CL) [OK].
Close the ‘Install’ window.

14.
Change the Mode from [Modify Mode] to [View Mode].

INST05-02-650
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-10

5.3 Change Configuration SVP Procedure


5.3.1 Setting up the New Device Structure Information

1. <Mode Change>
Change the mode to Modify Mode.
Select (CL) [Install].

2. <Start the ‘Menu Dialog’ screen>


Select (CL) [Change Configuration].

3. <Start Device Structure Setup screen>


Select (CL) the item in the ‘Menu Dialog’
dialog box and select (CL) [OK].

Function Menu Item


• System Option ----------------------- System Option (INST05-03-20)
• DCR Configuration ----------------- DCR Configuration (INST05-03-40)
• CVS Configuration ------------------ CVS Configuration (INST05-03-90)
• LUN Management ------------------ LUN Configuration (INST05-03-450)

INST05-03-10
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-20

5.3.1.1 System Option

1. <Definition of System Option>


Define the system option information in the ‘System
Option’ window.

When [WR.Through] is selected (CL), go to Step 2.

After all the items are set, select (CL) [OK].


Go to Step 3.

2. <Setting Destage Mode>


Set the destage mode in the ‘Synchronous Destage Mode
Define’ window.

When [OK] is selected (CL), return to Step 1.

3.
“Change Configuration was completed.” is
displayed.
Selection (CL) [OK].

INST05-03-20
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-30

4.
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

5.
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media, select
(CL) [OK].

6.
After the procedure is completed, return to
‘Install’.
Select (CL) [File]-[Exit].

7.
Change the Mode from [Modify Mode] to [View Mode].

INST05-03-30
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-40

5.3.1.2 DCR Configuration

(1)
The “DCR Change” window appears and the
contents of the entered setting are displayed. When
the CU is selected (DR) in the combo box, installed
LDEV(s) and contents of the DCR definition are
updated. Select (CL) LDEV to change the setting,
then press (CL) the [Define...] button.

Total cache memory size occupied by the DCR area


is displayed.

If the selected LDEV has a DCR area, the BIND


size and the PRIO size are displayed in “DCR
Change” window.

NOTICE: To use DCR function, you should install the program product for mainframe
volumes or for open volumes into the DKC. Do not set DCR function to
Remote Command Device.

(2)
The “DCR Detail (Logical Device)” screen
appears and the setting of the DCR in the
LDEV is displayed.
To add a new setting, press (CL) the [Set...]
button.

INST05-03-40
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-50

(3)
When the [Set...] button is pressed (CL) on the “DCR Detail (Logical Device)” screen, the
“DCR Define” screen appears. To register new data in the DCR area, enter the type, starting
cylinder number, starting head number, ending cylinder number, and ending head number (In
the case of Mainframe, refer to the screen on the right) or the type, starting LBA, and ending
LBA (In the case of the open system, refer to the screen on the left).
If you want to stage the data on the cache, check the Prestaging Request box.
When the entry is completed, return the screen to the “DCR Detail (Logical Device)” screen by
pressing (CL) the [OK] button.

(In the case of open system) (In the case of Mainframe system)

(4)
Contents of the entered
setting are displayed in
the list box on the
“DCR Detail (Logical
Device)” screen.

(In the case of open system) (In the case of Mainframe system)

(5)
To delete a set item, select (CL) the DCR setting to be
deleted and press (CL) the [Delete] button on the “DCR
Detail (Logical Device)” screen.

INST05-03-50
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-60

(6)
By pressing (CL) the [OK] button on the
“DCR Detail (Logical Device)” screen after
the new setting is entered, a process to change
the setting for the LDEV is executed.
When no change is required, press (CL) the
[Cancel] button.

(7)
The screen returns to
the “DCR Change”
screen after the
processing is
completed. The
changed setting is
displayed in the list
box.

(In the case of open system) (In the case of Mainframe system)

(8)
Repeat steps (1) through (7) for the LDEV(s) of which you want to change the setting.

(9)
When you want to set DCR PreStaging, select (CL) [PreStaging].
The [PreStaging] button begins the Pre-staging processing only for the “PreStaging Request”
specified data.

INST05-03-60
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-70

(10)
When the changing operation is completed, quit the “DCR Change” screen by pressing (CL)
the [Exit] button.

(11)
“Change Configuration was completed.” is
displayed.
Select (CL) [OK].

(12)
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

(13)
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media,
select (CL) [OK].

INST05-03-70
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-80

(14)
After the procedure is completed, return to
‘Install’ window.
Select (CL) [File]-[Exit].

(15)
Change the mode from [Modify Mode] to [View Mode].

INST05-03-80
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-90

5.3.1.3 CVS Configuration

• Volume to Space -------------------------- Go to Step 1.


• LDEV (CVS) Installation---------------- Go to Step 2.
• Volume Initialize ------------------------- Go to Step 3.

1. <Volume to Space>

NOTICE: When you set Cross-OS File Exchange volumes to customized volumes and
reset them to the normal volume again, these volumes could not be set as
Cross-OS File Exchange volumes. Please refer to the following table.
Emulation Types for Cross-OS File Emulation types after changing from
Exchange volumes Customized volume to normal volume
3390-3A 3390-3
3390-3B
3390-3C

If you want to reset these volumes as Cross-OS File Exchange, please call
technical support division to set them to Cross-OS File Exchange volumes by
SVP.

INST05-03-90
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-100

(1)
Select (CL) [Volume to Space] and select
(CL) [OK].

NOTICE: To use CVS function, you should install the program product for mainframe
volumes or for open volumes into the DKC.

CAUTION
This is a special (exceptional) operation that can cause a serious failure such as a
system down or a data loss and requires an input of a password. Ask the technical
support division about the appropriateness of the operation, and input the password after
getting an approval of executing the operation.
NOTE: When the Volume to Space function is performed, the alias information which is set to
the specified LDEV is also deleted.
If you set the alias to the LDEV, you must migrate the alias information to another
LDEV before the Volume to Space function is performed, or you must reconfigure the
alias after the Volume to Space function is performed.

Enter the password and select (CL) [OK].

INST05-03-100
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-110

(2)
Select (CL) a parity group with Volume(s) to
be changed on the ‘Device Emulation
Configuration’ window and press (CL) the
[Detail...] button.

When all the settings are completed, press


(CL) [>>Next]. Go to Step (4).

(CVS): A parity group where CVS is


installed.
Grp*: A parity group where RAID
Concatenation is installed.

INST05-03-110
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-120

(3) <Definition other than OPEN-V>


When the Volume(s) to be deleted is selected
(CL) on the ‘Customized Volume Size
Define’ window and the [Delete] button is
pressed (CL), the Volume(s) is deleted.
The two or more volumes can be selected and
deleted. However, the last one volume cannot
be deleted.

• Offset Boundary :
The boundary correction existence is specified.
(When a volume for mainframe host is selected, it is not possible to select it.)

• Capacity Unit
“Cylinder” : Makes data displayed or entered by the Cylinder.
“Blocks” : Makes data displayed or entered by the Blocks.
(When a volume for mainframe host is selected, it became selection of only “Cylinder”.)

[Delete] : Deletes a selected volume.


[Cancel] : Invalidates the setting and makes the preceding window return. Return to Step
(2).
[OK] : Fixes the setting and makes the preceding window return. Return to Step (2).

NOTE: In the following case, the [Delete] button is not available.


 Volume with SCSI path(s) (“+” indicated) is selected.
 Volume with pool-VOL (“+” indicated) is selected.
 Volume with the journal volume (“+” indicated) is selected.

INST05-03-120
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-130

(3-1) <Definition of OPEN-V>


When you select a volume you want to delete
in the ‘Variable Volume Size Define’ window
and select (CL) the [Delete], the volume is
deleted.
The two or more volumes can be selected and
deleted. However, the last one volume cannot
be de deleted.

• Offset Boundary : The boundary correction existence is specified.


• Capacity Unit
“Cylinder” : Makes data displayed or entered by the Cylinder.
“Blocks” : Makes data displayed or entered by the Blocks.
• asst. : When Path/pool-VOL/the journal volume is defined, “+” is displayed.
[Delete] : Deletes a selected volume.
[Cancel] : Invalidates the setting and makes the preceding window return. Return to Step
(2).
[OK] : Fixes the setting and makes the preceding window return. Return to Step (2).

NOTE: In the following case, the [Delete] button is not available.


 Volume with SCSI path(s) (“+” indicated) is selected.
 Volume with pool-VOL (“+” indicated) is selected.
 Volume with the journal volume (“+” indicated) is selected.

INST05-03-130
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-140

(4) <Display LDEV Path Group ID>


When some of the LDEVs to be uninstalled
are connected to hosts because a Vary On-line
operation was performed, the “LDEV Path
Group ID Display” window appears.

LDKC/CU/LDEV:
Only the LDEVs to be installed, which are
connected to hosts, are displayed
Path Group ID:
List of Path Group IDs of the hosts
connected to the LDEVs to be uninstalled.
Depending on the host, the LPAR information may be registered in the 4th byte of the Path
Group ID (7th and 8th characters on the window. “01” on the window above), and the host
serial number may be registered in the 5th and 6th bytes (9th to 12th characters on the
window. “0BD2” on the window above).

After clicking [OK], click [Yes] for the


message, “Some LDEVs are logically
connected to hosts because a Vary On-line
operation was performed. Do you want to
stop this process?”
After that, disconnect all the LDEVs to be
uninstalled from the host and perform the
uninstallation again.

INST05-03-140
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-150

(5)
Select (CL) [Yes] in response to “The
Volume To Space will be performed. Are you
sure you want to renew storage system?”.

When [No] is selected (CL), returns to


INST05-03-10 Step 2.

(6)
“Renewal process has completed. Please
check storage system status.” is displayed
when recovery processing on all installed
components is completed. Select (CL) [OK]
in response to this message.

(7)
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

INST05-03-150
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-160

(8)
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media, select
(CL) [OK].

(9)
After the procedure is completed, return to
‘Install’.
Select (CL) [File]-[Exit].

(10)
Change the mode to View Mode.

INST05-03-160
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-170

2. <LDEV(CVS) Installation>
(1)
Select (CL) [LDEV(CVS) Installation] and
select (CL) [OK].

(2)
Select (CL) a parity group to which the CV(s)
is to be added on the “Device Emulation
Configuration” screen and press (CL) the
[Detail] button.

When all the settings are completed, press


(CL) [>>Next]. Go to Step (4).

(CVS): A parity group where CVS is


installed.
Grp*: A parity group where RAID
Concatenation is installed.

INST05-03-170
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-180

(3)
A volume other than OPEN-V can be defined
in the ‘Customized Volume Size Define’
window.
• Add of CVS
Perform  Add of the Volume.

 Add of the Volume


A volume can be added by entering the
LDEV emulation type and the user size
(MByte/Blocks or Cylinder) of the
customized volume (CV) and selecting [Add].
(It can be added in the optional space “empty” by selecting (CL) “empty” from the LDEV
list box.)
The two or more CVs can be registered when the operation above is performed repeatedly.

• Offset Boundary :
The boundary correction existence is specified.
(When a volume for mainframe host is selected, it is not possible to select it.)

• Capacity Unit
“Cylinder” : Makes data displayed or entered by the Cylinder.
“Blocks” : Makes data displayed or entered by the Blocks.
(When a volume for mainframe host is selected, it became selection of only “Cylinder”.)

INST05-03-180
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-190

The contents registered are displayed in the


list box.
The deletion can be made only for the added
CV(s). When the addition is made incorrectly,
select (CL) [Cancel] to make the setting
invalid and perform the setting again.

[OK] : Fixes the setting and makes the


preceding window return. Return
to Step (2).
[Cancel] : Invalidates the setting and makes
the preceding window return. Return to Step (2).

INST05-03-190
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-200

(3-1) Definition of OPEN-V


OPEN-V can be defined in the ‘Variable
Volume Size Define’ window.
• Add of CVS
Perform  Add of the Volume.

 Add of the Volume


After selecting the “Specify Size &
number” in the ‘Variable Volume Size
Define’ window and entering user size and number of volumes to be added, register a
volume by selecting (CL) the [Add].
(It can be added in the optional space “empty” by selecting (CL) “empty” from the LDEV
list box.)
After adding CVS, check that “CVS” is displayed for the added volume in the LDEV list
box.

The volume that have been registered are displayed in the list box. Only the added volume can
be deleted.

• Variable Volume Size


“Specify size & number” : Defines the specified number of the specified user size.
• Offset Boundary : The boundary correction existence is specified.

INST05-03-200
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-210

• Capacity Unit
“MByte” : Makes data displayed or entered by the MByte.
“Cylinder” : Makes data displayed or entered by the cylinder.
“Blocks” : Makes data displayed or entered by the Blocks.
• asst. : When Path/pool-VOL/the journal volume is defined, “+” is displayed.
[Delete] : Deletes a selected volume.
[Add] : Adds a volume.
[Cancel] : Invalidates the setting and makes the preceding window return. Return to Step
(2).
[OK] : Fixes the setting and makes the preceding window return. Return to Step (2).

INST05-03-210
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-220

(4)
Set LDEV ID(s) for the added CV(s). For the
parity group having the added CV(s), the
status which shows the ID allocation is
indicated as “-------”. Therefore, select (CL)
such a parity group.

[Linear...]: LDEV ID is assigned to LDEV


in the order of parity group. Go
to Step (5).
[Disperse...]:LDEV ID is assigned discretely
in the order of parity group. Go
to Step (5).
[Detail...]: A screen to define LDEV in
detail is displayed. Go to Step
(5-1).

Grp*: The top parity group where RAID Concatenation is installed.


Status: Status of LDEV ID.
 “Complete” : LDEV ID is assigned.
 “-------” : LDEV ID is not assigned.
 “Error” : Invalid LDEV ID is assigned.

(5)
Press (CL) the [Linear...] button and enter an
LDEV ID you want to allocate on the
“Logical Device ID Define” screen.

Make sure that the entered item is correct and


select (CL) [OK]. Go to Step (6).

NOTE: The definition range (terminal) is


decided with LDEV Range.
For example, if LEDV Range is
defined as 7F, LDEV ID is assigned
only within the range of 00 to 7F.

INST05-03-220
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-230

(5-1)
When the [Detail...] is pressed (CL), the
‘Logical Device ID Detail’ window is
displayed. Select an emulation type for which
the LDKC, CU and ID status are displayed as
“--:--:--” and select (CL) [Change...]. Go to
Step (5-2).
When you want to register successive IDs,
you can select the two or more emulation
types.
NOTE: In the case of a RAID Concatenation
Group, LDEV of the parity group
selected by the “Grp List” is
displayed.

(5-2)
Enter LDKC, a CU and LDEV ID you want to
allocate on the ‘Logical Device ID Define’ window.
Then, select (CL) [OK].
Go to Step (5-3).
NOTE: The definition range (terminal) is decided
with LDEV Range.
For example, if LEDV Range is defined as
7F, LDEV ID is assigned only within the
range of 00 to 7F.

(5-3)
Make sure that the LDKC(s), the CU(s) and
ID(s) have been registered.
If there is any emulation type for which the
LDKC, CU and ID status are displayed as “--
:--:--”, return to Step (5-1).
If all the settings have been made, select (CL)
[OK]. Go to Step (6).

INST05-03-230
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-240

(6)
When the screen is returned to the ‘Logical
Device ID Configuration’ window, the setting
result is displayed.

If the status of a parity group shows other


than “Complete”, return to Step (4).
After all the settings are completed, select
(CL) [Detail...] to check the settings, and then
select (CL) [>>Next]. Go to Step (7).

Grp*: The top parity group where RAID


Concatenation is installed.
Status: Status of LDEV ID.
 “Complete” : LDEV ID is assigned.
 “-------” : LDEV ID is not assigned.
 “Error” : Invalid LDEV ID is assigned.

(7)
If a new SSID is required as a result of defining an
LDEV ID, define the new SSID. Select (CL) a storage
system where the SSID is to be newly defined and
press (CL) the [SS ID...] button. Go to Step (8).
When no SSID is to be defined, selecting [>>Next].
Go to Step (9).

INST05-03-240
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-250

(8)
Enter the SSID on the “SSID Define” screen and select
(CL) [OK]. Go to Step (9).

(9)
When the screen is returned to the “SSID
Configuration” screen by pressing (CL) the [OK]
button, the set contents are displayed.

When [>>Next] is selected (CL), the definition of the


addition ends. (Additional process starts.) Go to Step
(10).

INST05-03-250
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-260

(10)
In the ‘LDEV Management MPB
Configuration’ window, select (CL) [Change
MPB].
Go to Step (11).

(11)
Define Management MPB and select (CL) [OK].
Go to Step (12).

(12)
When the screen is returned to the ‘LDEV
Management MPB Configuration’ window,
the setting result is displayed.

Make sure that the entered item is correct and


select (CL) [>>Next]. Go to Step (13).

INST05-03-260
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-270

(13) <Selection of format>


Select (CL) [Yes] in response to “Do you
want to format logical devices by Quick
Format?” when you execute Quick Format.
When [No] is selected (CL), usual LDEV
Format is executed.

NOTE: Next, Quick Format cannot be


executed in the shown volume.
• external volume
• Volumes whose access attribute is not Read/Write
• Pool volumes (pool-VOLs)
• Journal volumes

When [Yes] is selected Go to Step (14).


When [No] is selected Go to Step (15).

(14) <Execution of Quick Format>


For the message “Quick Format is executed.
Do you continue to this operation?
[Yes]: Quick Format is executed.
[No]: Format is executed.”, select (CL) [Yes]
when Quick Format is to be executed. Select
(CL) [No] when normal LDEV format is to be
executed.

INST05-03-270
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-280

(15)
Select (CL) [Yes] in response to “The
LDEV(CVS) Installation will be performed.
Are you sure you want to renew storage
system?”.

When [No] is selected (CL), returns to


INST05-03-10 Step 2.
NOTE: On page INST05-03-270 (14), it
advances to (16-1) when a Quick Format is selected (CL).

INST05-03-280
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-290

(16)
“Formatting logical devices...” is displayed.
NOTE: When System Option 269 is set and all
LDEVs in ECC Group are other than the
format target, SIM = 0x4100XX is not
output at the end even.

(16-1)
“Preparing Quick Format logical devices...” is
displayed.

(17)
“Renewal process has completed. Please
check storage system status.” is displayed
when recovery processing on all installed
components is completed. Select (CL) [OK]
in response to this message.

(17-1) <QUICK FORMAT>


Refer to the logical device window in the ‘Maintenance’ window to check that the Quick
Format is in progress. (SVP03-06-10 through 100)

INST05-03-290
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-300

(18)
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

(19)
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media,
select (CL) [OK].

(20)
After the procedure is completed, return to
‘Install’.
Select (CL) [File]-[Exit].

(21)
Change the mode to View Mode.

INST05-03-300
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-310

NOTICE: When you set Cross-OS File Exchange volumes to customized volumes and
reset them to the normal volume again, these volumes could not be set as
Cross-OS File Exchange volumes. Please refer to the following table.
Emulation Types for Cross-OS File Emulation types after changing from
Exchange volumes Customized volume to normal volume
3390-3A 3390-3
3390-3B
3390-3C

If you want to reset these volumes as Cross-OS File Exchange, please call
technical support division to set them to Cross-OS File Exchange volumes by
SVP.

3. <Volume Initialize>
(1)
Select (CL) [Make Volume], then select (CL)
[OK].

CAUTION
This is a special (exceptional) operation that can cause a serious failure such as a
system down or a data loss and requires an input of a password. Ask the technical
support division about the appropriateness of the operation, and input the password after
getting an approval of executing the operation.

Enter the password and select (CL) [OK].

INST05-03-310
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-320

(1-1)
Select (CL) [>>Next].
Go to Step (2).

INST05-03-320
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-330

(2)
A parity group can initialize of LDEV in the
‘Device Emulation Configuration’ window.

Select (CL) a parity group with Volume(s) to


be initialized on the ‘Device Configuration’
window, and press (CL) the [MakeVolume]
button. Go to Step (2-1).

When all the settings are completed, press


(CL) [>>Next]. Go to Step (4).

(CVS): A parity group where CVS is installed.


Grp*: A parity group where RAID Concatenation is installed.
asst.: A parity group where the Make Volume process cannot be performed because it
includes the LDEV in which Path/pool-VOL/the journal volumes is set.

(2-1)
A message, “The selected device(s) will be
initialized. Are you sure you want to initialize
the selected device(s)?” is displayed. Select
(CL) [Yes].

INST05-03-330
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-340

(2-2) Definition of OPEN-V


OPEN-V can be defined in the ‘Variable
Volume Size Define’ window.
• Add of the Volume
After selecting the “Specify Size & number”
in the ‘Variable Volume Size Define’
window and entering user size and number
of volumes to be added, register a volume
by selecting (CL) the [Add].
(It can be added in the optional space “empty” by selecting (CL) “empty” from the LDEV
list.)

The volume that has been registered is displayed in the list box. Only the added volume can be
deleted.

• Variable Volume Size


“Specify size & number” :
Defines specified number of specified user sizes.
• Offset Boundary :
The boundary correction existence is specified.

INST05-03-340
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-350

• Capacity Unit
“MByte” : Makes data displayed or entered by the MByte.
“Cylinder” : Makes data displayed or entered by the cylinder.
“Blocks” : Makes data displayed or entered by the Blocks.
• asst. : When Path/pool-VOL/the journal volume is defined, “+”
is displayed.
[Clear] : Deletes all the volumes.
[Delete] : Deletes a selected volume.
[Add] : Adds a volume.
[Cancel] : Invalidates the setting and makes the preceding window return. The routine is
returned to Step (2).
[OK] : Fixes the setting and makes the preceding window return. The routine is returned
to Step (2).

INST05-03-350
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-360

(3)
To return the volume(s) in other parity group(s) to the normal LDEV(s), repeat Step (2).
Return to Step (2).

(4)
Set LDEV ID(s) for the added LDEV(s). For
the parity group having the added LDEV(s),
the status which shows the ID allocation is
indicated as
“-------”. Therefore, select (CL) such a parity
group.

[Linear...]: LDEV ID is assigned to LDEV


in the order of parity group. Go
to Step (5).
[Disperse...]:LDEV ID is assigned discretely
in the order of parity group. Go
to Step (5).
[Detail...]: A screen to define LDEV in
detail is displayed. Go to Step
(5-1).

Grp*: The top parity group where RAID Concatenation is installed.


Status: Status of LDEV ID.
 “Complete” : LDEV ID is assigned.
 “-------” : LDEV ID is not assigned.
 “Error” : Invalid LDEV ID is assigned.

(5)
Press (CL) the [Linear...] button and enter an LDEV
ID you want to allocate on the “Logical Device ID
Define” screen.

Make sure that the entered item is correct and select


(CL) [OK]. Go to Step (6).

NOTE: The definition range (terminal) is decided


with LDEV Range.
For example, if LEDV Range is defined as
7F, LDEV ID is assigned only within the
range of 00 to 7F.

INST05-03-360
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-370

(5-1)
When the [Detail...] is pressed (CL), the
‘Logical Device ID Detail’ window is
displayed. Select an emulation type for which
the LDKC, CU and ID status are displayed as
“--:--:--” and select (CL) [Change...]. Go to
Step (5-2).
When you want to register successive IDs,
you can select the two or more emulation
types.
NOTE: In the case of a RAID Concatenation
Group, LDEV of the parity group
selected by the “Grp List” is
displayed.

(5-2)
Enter LDKC, a CU and LDEV ID you want to
allocate on the ‘Logical Device ID Define’ window.
Then, select (CL) [OK].
Go to Step (5-3).
NOTE: The definition range (terminal) is decided
with LDEV Range.
For example, if LDEV Range is defined as
7F, LDEV ID is assigned only within the
range of 00 to 7F.

(5-3)
Make sure that the LDKC(s), CU(s) and ID(s)
have been registered.
If there is any emulation type for which the
LDKC, CU and ID status are displayed as “--
:--:--”, return to Step (5-1).
If all the settings have been made, select (CL)
[OK]. Go to Step (6).

INST05-03-370
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-380

(6)
When the screen is returned to the ‘Logical
Device ID Configuration’ window, the setting
result is displayed.

If the status of a parity group shows other


than “Complete”, return to Step (4).
When all the settings are completed, press
(CL) [>>Next]. Go to Step (7).

Grp*: The top parity group where RAID


Concatenation is installed.
Status: Status of LDEV ID.
 “Complete” : LDEV ID is assigned.
 “-------” : LDEV ID is not assigned.
 “Error” : Invalid LDEV ID is
assigned.

(7)
If a new SSID is required as a result of defining an
LDEV ID, define the new SSID. Select (CL) a storage
system where the SSID is to be newly defined and
press (CL) the [SS ID...] button. Go to Step (8).

When no SSID is to be defined, selecting [>>Next].


Go to Step (10).

(8)
Enter an SSID on the ‘SSID Define’ window and
select (CL) [OK]. Go to Step (9).

INST05-03-380
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-390

(9)
When the screen is returned to the ‘SSID
Configuration’ window, the registered SS ID is
displayed.
Press (CL) the [>>Next] button to quit the definition
screen.
Go to Step (10).

INST05-03-390
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-400

(10)
In the ‘LDEV Management MPB
Configuration’ window, select (CL) [Change
MPB].
Go to Step (11).

(11)
Define Management MPB and select (CL) [OK].
Go to Step (12).

(12)
When the screen is returned to the ‘LDEV
Management MPB Configuration’ window,
the setting result is displayed.

Make sure that the entered item is correct and


select (CL) [>>Next]. Go to Step (13).

INST05-03-400
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-410

(13) <Selection of format>


Select (CL) [Yes] in response to “Do you
want to format logical devices by Quick
Format?” when you execute Quick Format.
When [No] is selected (CL), usual LDEV
Format is executed.

NOTE: Next, Quick Format cannot be


executed in the shown volume.
• external volume
• Volumes whose access attribute is not Read/Write
• Pool volumes (pool-VOLs)
• Journal volumes

When [Yes] is selected Go to Step (13-1).


When [No] is selected Go to Step (14).

(13-1) <Execution of Quick Format>


For the message “Quick Format is executed.
Do you continue to this operation?
[Yes]: Quick Format is executed.
[No]: Format is executed.”, select (CL) [Yes]
when Quick Format is to be executed. Select
(CL) [No] when normal LDEV format is to be
executed.

INST05-03-410
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-420

(14)
Select (CL) [Yes] in response to “The Make
Volume will be performed. Are you sure you
want to renew storage system?”.

When [No] is selected (CL), returns to


INST05-03-10 Step 2.
NOTE: When System Option 503 is set,
LDEV Format is not executed and
the message “The newly installed LDEV has not been formatted. Please format the
newly installed LDEV after the maintenance operation has completed.” is displayed.
If [OK] is selected (CL) for this message, it goes to Step (13).
NOTE: On page INST05-03-410 (13-1), it advances to (15-1) when a Quick Format is
selected (CL).

(15)
“Formatting logical devices...” is displayed when
LDEV Format is necessary.
NOTE: When System Option 269 is set and all
LDEVs in ECC Group are other than the
format target, SIM = 0x4100XX is not
output at the end even.

(15-1)
“Preparing Quick Format logical devices...” is
displayed.

INST05-03-420
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-430

(16)
“Renewal process has completed. Please
check storage system status.” is displayed
when recovery processing on all installed
components is completed. Select (CL) [OK]
in response to this message.

(17)
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

(18)
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media,
select (CL) [OK].

INST05-03-430
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-440

(19)
After the procedure is completed, return to
‘Install’.
Select (CL) [File]-[Exit].

(20)
Change the mode to View Mode.

INST05-03-440
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-450

5.3.1.4 LUN Management

(1) Outline


 

Figure 5.3.1.4-1-1 Main Window

The Main window consists of the following elements.

Table 5.3.1.4-1-1 Outline of Main Window Elements


No. Item Description
 Menu Menu of items operable by this function.
 Tool bar Part of the menu enabled to be operable by buttons.
 Switch When “Switch” displayed in the tree view is selected (Port), the status of the
switch is selectable. The setting of the groups or LUN is selectable.
 Tree The structure that it is conscious of the hardware construction.
(A port type is attached to a port.)
 Upper right list Displays the details of an item selected from the tree.
 Lower right list Displays the details of an item selected from the upper list, if any.
 Status bar Displays outlined function of each item on the menu and tool bar when the mouse
is positioned on it. Also it displays the all of the LU figures and the LU figures
with the pass definition.

INST05-03-450
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-460

NOTE: If the error has occurred by the setting of LUN Management that was started from
Change Configuration, refer to “2.3.1 Action When LUN Management Setting on
SVP Change Configuration Failed” (TRBL02-240) of the TROUBLE SHOOTING
SECTION.

NOTICE: If you change the settings,


message asking for a
confirmation is displayed.
Please confirm the message.
Select(CL) [Yes] button, continue
this process.

INST05-03-460
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-470

Menu items and their details are shown below.

Table 5.3.1.4-1-2 List of Menu Items


Menu Submenu Description Tool bar
File Exit  Closes the window. “Exit”
Edit Copy  Copies group / WWN / LUN to the clip board. None
Paste  Pastes the information of the clip board. None
View Toolbar  Makes the tool bar displayed or not. None
Status Bar  Makes the status bar displayed or not. None
LDEV Size  Changes the unit of LDEV size to be displayed to MB None
GB or TB.
LUN Status  Displays/does not display the LUN status (including None
the Host reserve status) in the LUN list.
Group New...  Creates a new group. “New”
Change...  Changes a group name or adds a member. “Change”
Delete  Deletes a group. “Delete”
Host Mode  Refers to the Host Mode and the Host Mode Option. None
WWN Add...  Adds a WWN and its nickname. “Add”
Change...  Changes a WWN and its nickname. “Change”
Delete  Deletes a WWN. “Delete”
Login List The hosts identified by the following WWN login to the “List”
DKC. (Only WWN has the deletion function.)
LUN Add...  Adds a LUN. “Add”
Delete  Deletes a LUN. “Delete”
Command Device  Changes command device and command device “Cmd”
security information.
Force Reset  Cancels the Host reserve status of the selected LUN. None
(When the [View] – [LUN Status] menu cannot be
selected, this menu does not exist.)
(To be continued)

INST05-03-470
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-480

(Continued from the preceding page)


Menu Submenu Description Tool bar
Port Parameter...  Changes a port parameter. “Port”
Security Switch...  Sets whether to use the security function or not. “Switch”
LDEV Command Device...  Changes command device and command device “Cmd”
security information.
Alternate  Refers to LUN information from LDEV. None
Besides, it is possible to eliminate a LUN through the
“Alternate” window started.

INST05-03-480
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-490

Restriction item

1. LUN and Group Configuration executable check item

Table 5.3.1.4-1-3 System operating condition, and change of configuration


# Item Operation Host I/O Pair Status
1 Group Add  
2 Delete A 
3 Group Name Modify  
4 Host Mode Modify B 
5 WWN Add  
6 Delete  
7 Modify  
8 LUN Add  
9 Delete C D

A: When the specified group has LUN and the LUN is reserved by the host or executing the I/O,
the specified group cannot be deleted.
B: When the specified group has LUN and the LUN is reserved by the host or executing the I/O,
the specified Host Mode of the group cannot be modified. I/O check (Host I/O) will not be
performed on a modification of Host Mode Option.
C: When the specified group has LUN and the LUN is reserved by the host or executing the I/O,
the specified LUN cannot be deleted.
D: When the pair volume of TrueCopy/ShadowImage/Thin Image (including the reserve volume of
ShadowImage) has no LUN by deleting LUN, the specified LUN cannot be deleted.

INST05-03-490
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-500

2. Port parameter check item

Table 5.3.1.4-1-4 System operating condition, and change of configuration


# Item Operation Host I/O Remaining pass Remaining Copy
MCU-RCU Volume
1 AL-PA Modify A B C
2 Topology Modify A B C
3 Channel Modify A  
Speed
4 Security Modify   
Switch

A: When the LUN in the specified port is reserved by the host or is executing the I/O, the
parameter cannot be modified.
B: When the path between MCU and RCU of the TrueCopy is formed with the port of the CHT,
the parameter cannot be modified.
C: When the copy volume of RCU of the TrueCopy exists in the port, the parameter cannot be
modified.

INST05-03-500
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-510

3. Command device check item

Table 5.3.1.4-1-5 System operating condition, and change of configuration


# Item Operation Host I/O Pair Status Guard Status
1 Command Device Set A B D
2 Clear C  
3 Command Device Set C  
4 Security Clear C  
5 User Authentication Set C  
6 Clear C  
7 Device Group Set C  
8 Definition Clear C  

A: When the LUN to the specified volume is reserved by the host or is executing the I/O, the
Command Device cannot be set.
B: When the specified volume is TrueCopy/ShadowImage volume, the Command Device cannot
be set.
C: R/W has to be stopped when this parameter is modified.
D: A volume with an attribute other than R/W, or VMA setting volume cannot be defined as a
command device.

INST05-03-510
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-520

(2) Setting Security Switch

Figure 5.3.1.4-2-2
Security Switch Window

Figure 5.3.1.4-2-1 Main Window

Figure 5.3.1.4-2-3 SEC3348W

Figure 5.3.1.4-2-4 SEC3347W

Figure 5.3.1.4-2-5 SEC2379W

INST05-03-520
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-530

When each CHA location in the tree view is selected (CL), installed ports information supported by
this function are displayed in the upper right list.

Setting of a Security Switch is made in the following procedure.


 Select (CL) a port for which you want to set the security switch from the upper right list.
 Select (DR) [Security Switch...] from the [Port] menu.
 Since the Security Switch window (Figure 5.3.1.4-2-2) is displayed, check On or Off box and
select (CL) the [OK] button.
When the Security Switch to On, message (Figure 5.3.1.4-2-3) is displayed, select (CL) the
[Yes] button.
When the Security Switch to Off, message (Figure 5.3.1.4-2-4) is displayed, select (CL) the
[Yes] button.
 Message (Figure 5.3.1.4-2-5) is displayed, select (CL) the [Yes] button.
 The status of the security switch that has been set is reflected in the Main window (Figure
5.3.1.4-2-1).

Details of the Main window (Figure 5.3.1.4-2-1) and the Security Switch window (Figure 5.3.1.4-2-
2) are shown on the following page.

INST05-03-530
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-540

Table 5.3.1.4-2-1 Details and Operation of Main Window (Switch)


Item Description
Upper list Displays statuses of the security switches that have been set.
Provided with a sorting function.
Lower list Displays nothing.
“Port - Security Switch...” menu Selectable when an item has been selected from the upper list.
Displays the Security Switch window.
Pop-up menu Enables a clicking of the right mouse button to select “Security Switch”
provided that an item has been selected from the upper list.

Table 5.3.1.4-2-2 Details and Operation of Security Switch Window


Item Description
On/Off radio button Displays a status setting of the Security Switch that has been selected in
the Main window. (If On and Off of the switch have been selected in the
Main window, the radio buttons of ON and OFF are not selected in this
window, and [OK] button cannot be selected.)
OK button Closes the window after reflecting the setting that has been made.
Not selectable when neither of the statuses has been selected.
Cancel button Closes the window without reflecting the setting that has been made.

INST05-03-540
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-550

(3) Setting Group


(3-1) Adding Group

Figure 5.3.1.4-3-4
Host Mode
Selection Window

Figure 5.3.1.4-3-1
Main Window

Figure 5.3.1.4-3-3
Port Selection Window
Figure 5.3.1.4-3-2
Add Group Window

Figure 5.3.1.4-3-6
Add WWN Window

Figure 5.3.1.4-3-5 Add WWN List Window

INST05-03-550
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-560

When “Port” in the tree view is selected, “Group” is set on the Display. Displays the group setting
in the port that has been selected in the upper right list.

Addition of a group is done in the following procedure.


 Select (DR) [New...] from the [Group] menu in the Main window (Figure 5.3.1.4-3-1).
 Since the Add Group window (Figure 5.3.1.4-3-2) is displayed, enter a group name.
 Register a WWN, and select (CL) the [Next>] button.
a) If you select the [WWN List...] button.
Since the Add WWN List window (Figure 5.3.1.4-3-5) is displayed, select (CL) a WWN in
the list, and select (CL) the [OK] button.
b) If you select the [Add...] button.
Since the Add WWN window (Figure 5.3.1.4-3-6) is displayed, input WWN and
Nickname, and select (CL) the [OK] button.
 Since the Port Selection window (Figure 5.3.1.4-3-3) is displayed, select (CL) a port for
connecting a new group and select (CL) the [Next>] button.
 Set a host mode for the new group in the Host Mode Selection window (Figure 5.3.1.4-3-4). If
you need to select an Option, see INST05-03-630 and set the bit, and then select (CL) the [OK]
button.
 Information on the group that has been newly registered is reflected in the Main window (Figure
5.3.1.4-3-1).

Details of the Main window (Figure 5.3.1.4-3-1) and the other windows are shown on the following
page.

INST05-03-560
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-570

Table 5.3.1.4-3-1 Details and Operation of Main Window (Group)


Item Description
Upper list Displays groups connected with the port that has been selected from the tree.
Provided with a sorting function.
“Group - New...” menu Selectable when “Port” has been selected from the tree.
Displays the Add Group window.
Pop-up menu Makes the “New” menu selectable when the right mouse button is clicked in
the upper list.

Table 5.3.1.4-3-2 Details and Operation of Add Group Window


Item Description
Name Enter a name of a group to be added in this box (using up to 64 characters).
List Displays a list of WWNs to be registered.
WWN List button Selects a WWN wanted to be registered from the Login WWN List. Makes the
registration to be reflected on the list after it is completed.
Add button Activates a window for manually registering a WWN. Makes the registration
to be reflected on the list after it is completed.
Change button Changes a selected WWN and its nickname. (Only one WWN can be
selected.)
Delete button Deletes a selected WWN from the list.
Next button Closes the window and activates a window for selecting a port to which the
group concerned is to be connected.
Cancel button Returns the window to the main window without doing anything.

Table 5.3.1.4-3-3 Details and Operation of Port Selection Window


Item Description
Name Displays the group name that has been entered in the preceding window.
List To be used for selecting a port to be connected.
Before button Returns you to the preceding window.
Next button Closes the window and activates a window for selecting a host mode for the
group concerned.
Cancel button Returns you to the Main window without doing anything.

Table 5.3.1.4-3-4 Details and Operation of Host Mode Window


Item Description
Host Mode Displays host modes that can be set.
If System Option 847 is ON, “Reserve” are displayed and selectable.
Before button Returns you to the preceding window.
OK button Closes the window after registering the group and returns you to the Main
window.
Cancel button Returns you to the Main window without doing anything.
Option button When this button is set to On, setting of the options from 0 to 127 becomes
possible. When the Host Mode is changed, the setting of the option is cleared.

INST05-03-570
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-580

(3-2) Changing Group

Figure 5.3.1.4-3-9
Host Mode Selection Window

Figure 5.3.1.4-3-7
Main Window

Figure 5.3.1.4-3-8 Change Group Window

Figure 5.3.1.4-3-11
Add WWN Window

Figure 5.3.1.4-3-10 Add WWN List Window

INST05-03-580
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-590

When “Port” in the tree view is selected, “Group” is set on the Display. Displays the group setting
in the port that has been selected in the upper right list. In the lower right list, details of a group that
has been selected from the upper right list are displayed.

A change of a group is made in the following procedure.


 Select (CL) one group you want to change from the upper right list.
 Select (DR) [Change...] from the [Group] menu in the Main window (Figure 5.3.1.4-3-7).
 Since the Change Group window (Figure 5.3.1.4-3-8) is displayed, change the group name.
 Register a WWN, and select (CL) the [Next>] button.
a) If you select the [WWN List...] button.
Since the Add WWN List window (Figure 5.3.1.4-3-10) is displayed, select (CL) a WWN
in the list, and select (CL) the [OK] button.
b) If you select the [Add...] button.
Since the Add WWN window (Figure 5.3.1.4-3-11) is displayed, input WWN and
Nickname, and select (CL) the [OK] button.
 Set a host mode for the group to be changed in the Host Mode Selection window (Figure 5.3.1.4-
3-9). If you need to select an Option, see INST05-03-630 and set the bit, and then select (CL) the
[OK] button.
 Information on the group that has been changed is reflected in the Main window (Figure 5.3.1.4-
3-7).

In case of changing the group against the port of the Security Switch off, the Change Group
window (Figure 5.3.1.4-3-8) is not displayed.

Details of the Main window (Figure 5.3.1.4-3-7) and the other windows are shown on the following
page.

INST05-03-590
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-600

Table 5.3.1.4-3-5 Details and Operation of Main Window (Group)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays details of a group that has been selected from the upper list.
(Displays nothing when no item to be selected exists in the upper list or
more than one item has been selected.)
Provided with a sorting function.
“Group - Change...” menu Selectable when a single group has been selected from the upper list.
Displays the Change Group window.
Pop-up menu Makes the “Change” menu selectable when a single group is selected
from the upper list and the right mouse button is clicked there.

Table 5.3.1.4-3-6 Details and Operation of Change Group Window


Item Description
Name Enter a name of a group to be added in this box (using up to 64
characters).
List Displays a list of WWNs to be registered.
WWN List button Selects a WWN wanted to be registered from the Login WWN List.
Makes the registration to be reflected on the list after it is completed.
Add button Activates a window for manually registering a WWN. Makes the
registration to be reflected on the list after it is completed.
Change button Changes a selected WWN and its nickname. (Only one WWN can be
selected.)
Delete button Deletes a selected WWN from the list.
Next button Closes the window and activates a window for selecting a port to which
the group concerned is to be connected.
Cancel button Returns the window to the main window without doing anything.

Table 5.3.1.4-3-7 Details and Operation of Host Mode Selection Window


Item Description
Host Mode Displays host modes that can be set.
If System Option 847 is ON, “Reserve” are displayed and selectable.
Before button Returns you to the preceding window.
OK button Closes the window after changing the group and returns you to the Main
window.
Cancel button Returns you to the Main window without doing anything.
Option button When this button is set to On, setting of the options from 0 to 127
becomes possible. When the Host Mode is changed, the setting of the
option is cleared.

INST05-03-600
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-610

(3-3) Deleting Group

Figure 5.3.1.4-3-12 Main Window

When “Port” in the tree view is selected, “Group” is set on the Display. Displays the group setting
in the port that has been selected in the upper right list. In the lower right list, details of a group that
has been selected from the upper right list are displayed.

Deletion of a group is done in the following procedure.


 Select (CL) a group you want to delete from the upper right list.
 Select (DR) [Delete] from the [Group] menu in the Main window (Figure 5.3.1.4-3-12).
 Since a message asking for a confirmation is displayed, select (CL) the [Yes] button.
 Information on the group that has been selected from the upper right list is deleted. Moreover,
the details of the group information (WWN/LUN) is also deleted.

INST05-03-610
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-620

Table 5.3.1.4-3-8 Details and Operation of Main Window (Group)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays details of a group that has been selected from the upper list.
(Displays nothing when no item to be selected exists in the upper list or
more than one item has been selected.)
Provided with a sorting function.
“Group - Delete” tool bar Selectable when a group has been selected from the upper list.
Displays a message asking for a confirmation.
Pop-up menu Displays “Delete” menu when the right mouse button is clicked on the
item in the upper list.

INST05-03-620
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-630

(3-4) Set and Change Host Mode Options

Figure 5.3.1.4-3-13 Figure 5.3.1.4-3-14


Host Mode Option window Host Mode Option window

When adding a new group, set options in the window shown in Figure 5.3.1.4-3-13. When changing
a group, set options in the window shown in Figure 5.3.1.4-3-14.
Do not set the check mark to the numbers other than the host mode option in Table 5.3.1.4-3-9.
If System Option 847 is ON, “Reserved” are displayed and selectable.

INST05-03-630
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-640

Table 5.3.1.4-3-9 Names and details of bits for Host Mode Options
Host Feature Scope Affected Criteria for
Mode Host Mode Application
Option (*1)
2 For Veritas VCS Apply this when Veritas DBE/AC for RAC Common Mandatory
and VCS4.0 or later (I/O Fencing feature)
are used.
6 For Windows TPRLO The Emulex FC adapter is used with SCSI 0C, 2C Mandatory
Miniport driver on windows.
And the driver parameter is set that
TPRLO=2.
7 For automatic device Apply this for SUN StorEdge SAN 00, 09 Option
discovery when adding Foundation Software Version 4.2 or later. It
LUN makes the host to recognize the increase and
decrease of the devices automatically when
a SUN generic HBA is connected.
12 For deleting Ghost Apply this when you want to prevent 03, 08 Option
LUN when HP-UX is unmounted devices from creating device (*2)
connected files in case where HP-UX is connected.
13 For reporting SIM when It reports SIM when a link failure occurs. Common Cannot be
a link failure occurs However, do not set this unless instructed. set
(*3)
14 For HP TruCluster Apply this when you want to use TruCluster 07 Mandatory
to set a cluster to each of P-VOL and S-VOL
for TrueCopy or Universal Replicator.
15 For HACMP Apply this when HACMP are used. 0F Mandatory
HACMP5.1 Version 5.1.0.4 or later/
HACMP4.5 Version 4.5.0.13 or later/
HACMP5.2 or later.
22 For Veritas Cluster Apply this when Veritas Cluster Server are 0F Mandatory
Server used.
23 REC command support It is applied when shortening the host Common Cannot be
recovery time at the time of the data transfer set
failure. (*3)
33 For a nickname of the Apply this when you want to enable 03, 08 Option
device with HP-UX commands to assign a nickname of the (*2)
hosts device with hosts, or to set UUID to identify 05
a logical volume from host. (*4) (*5)
39 Change the nexus This option is used to reset a job and return Common Option
specified in the SCSI UA to all the initiators connected to the host
Target Reset group when Target Reset is received.
(To be continued)

INST05-03-640
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-650

(Continued from the preceding page)


Host Feature Scope Affected Criteria for
Mode Host Mode Application
Option (*1)
40 V-VOL expansion When all the following conditions are 0C, 2C Option
satisfied:
• The host mode 0C Windows or 2C
Windows Extension is used.
• You want to automate recognition of the
TP-VOL capacity after increasing the TP-
VOL capacity.
41 Prioritized device When you want to execute commands to Common Option
recognition command recognize the device preferentially.
43 Queue Full Response When you want to make your VSP G1000 Common Option
storage system return a “queue full”
response (not “busy” response) to HP-UX
when the command queue is full.
49 BB Credit Setup When you hope for the TrueCopy Common Option
Option1 performance gain by BB Credit (*6) (*7)
virtualization, use by combining with Host
Mode Option 50.
50 BB Credit Setup When you hope for the TrueCopy Common Option
Option2 performance gain by BB Credit (*6) (*7)
virtualization, use by combining with Host
Mode Option 49.
51 Round Trip Setup When you hope for the TrueCopy Common Option
Option performance gain by Round Trip function. (*7)
54 Support option for the Apply this for VMware ESX/ESXi 4.1 with Common Mandatory
EXTENDED COPY VAAI function. Change the behavior of the
command (*8) EXTENDED COPY command that
conforms to SCSI-4 so that the command
corresponds to VMware ESX Server.
60 LUN0 Change Guard • When HP-UX Version 11.31 is used. Common Option
• When you want to guard adding or
deleting LUN0.
(To be continued)

INST05-03-650
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-660

(Continued from the preceding page)


Host Feature Scope Affected Criteria for
Mode Host Mode Application
Option (*1)
63 Support option for Apply this for VMware ESXi 5.0 or later Common Option
vStorage APIs based on with VAAI function based on T10 standards.
T10 standards (*9)
67 Change of the ED_TOV When you want to change ED_TOV value Common Mandatory
value on the target port which is direct connection
of Fabric = OFF and FC-AL, this is applied.
68 Support Page Apply this option when using page Common Option
Reclamation for Linux reclamation function for Linux.
71 Change the Unit Apply this option for changing sense key Common Option
Attention for Blocked from NOT READY to MEDIUM ERROR
pool-VOLs when a pool volume is blocked.
72 AIX GPFS Support Apply this option when you use AIX with Common Option
General Parallel File System (GPFS).
73 Support Option for Apply this option when using thin Common Option
WS2012 provisioning function for Windows Server
2012 (WS2012).

INST05-03-660
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-670

*1: Set the option when the configuration satisfies the description in Scope.
*2: In the XP7 series, it is enabled by Host Mode 08. In other models, it is enabled only by Host
Mode 03.
*3: Set this only when you are requested to do so.
NOTE: To obtain the latest detailed information including minimal microcode levels and any
restrictions associated with these modes please acquire the latest copy of the Mode
List from your support organization’s database or contact the support organization
directly.
*4: Please reboot OpenVMS when you make Host Mode Option No.33 from turning on to turning
off.
*5: Please allocate UUID in all LU when you make Host Mode Option No.33 from turning off to
turning on, and reboot OpenVMS.
*6: Please set both Host Mode Option No.49 and No.50 to use TrueCopy performance gain by BB
Credit.
*7: Host Mode Option No.49, No.50, and No.51 are applicable to only 8FC16/16FC8.
*8: XCOPY command that copies from one DKC to another DKC does not supported. Therefore,
turn off Host Mode Option 54 when you operate the cloning or Storage vMotion between
multiple DKCs with the ESX host.
*9: XCOPY command that copies from one DKC to another DKC does not supported. Therefore,
turn off Host Mode Option 63 when you operate the cloning or Storage vMotion between
multiple DKCs with the ESX host.

INST05-03-670
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-680

(4) Setting WWN


(4-1) Adding WWN

Figure 5.3.1.4-4-1 Main window

Figure 5.3.1.4-4-2
Add WWN Window

When “Port” in the tree view is selected, “Group” is set on the Display. Displays the group setting
in the port that has been selected in the upper right list. In the lower right list, details of a group that
has been selected from the upper right list are displayed.

Addition of a WWN is made in the following procedure.


 Select (CL) a group to which you want to add a WWN from the upper right list.
 Select (DR) [Add...] from the [WWN] menu in the Main window (Figure 5.3.1.4-4-1).
 Since the Add WWN window (Figure 5.3.1.4-4-2) is displayed, select(CL) “WWN” registering
from the list, and select (CL) the [OK] button.
 The WWN that has been newly added is reflected in the lower right list.

Details of the Main Window (Figure 5.3.1.4-4-1) and the other windows are shown on the
following page.

INST05-03-680
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-690

Table 5.3.1.4-4-1 Details and Operation of Main Window (WWN)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays details of a group that has been selected from the upper
list.(Displays nothing when no item to be selected exists in the upper list
or more than one item has been selected.)
Provided with a sorting function.
“WWN – Add...” menu Selectable when a single group has been selected from the upper list.
Displays the Add WWN window.
Pop-up menu Displays the “Add” menu when the right mouse button is clicked in the
lower list.

Table 5.3.1.4-4-2 Detail and Operation of Add WWN Registration Window


Item Description
Name Displays a group name. (The name is not allowed to be changed.)
List Displays a list of WWNs to be added. (WWNs that have been registered
are not displayed.)
Add button Activates a window for manually registering a WWN. Makes the
registration to be reflected on the list after it is completed.
WWN List button Selects a WWN wanted to be registered from the Login WWN List.
Makes the registration to be reflected on the list after it is completed.
Change button Changes a selected WWN and its nickname. (Only one WWN can be
selected.)
Delete button Deletes a selected WWN from the list.
OK button Registers a WWN that has been added and you return to the Main
window.
Cancel button Returns the window to the main window without doing anything.

INST05-03-690
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-700

(4-2) Changing WWN

Figure 5.3.1.4-4-3 Main Window


Figure 5.3.1.4-4-4
Change WWN Window

When “Port” in the tree view is selected, “Group” is set on the Display. Displays the group setting
in the port that has been selected in the upper right list. In the lower right list, details of a group that
has been selected from the upper right list are displayed.

A change of a WWN is made in the following procedure.


 Select (CL) one WWN you want to change from the lower right list.
 Select (DR) [Change...] from the [WWN] menu in the Main window (Figure 5.3.1.4-4-3).
 Since the Change WWN window (Figure 5.3.1.4-4-4) is displayed, change the “WWN” and its
“Nickname”, and select (CL) the [OK] button.
 The WWN that has been changed is reflected in the lower right list.

Details of the Main Window (Figure 5.3.1.4-4-3) and the other windows are shown on the
following page.

INST05-03-700
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-710

Table 5.3.1.4-4-3 Details and Operation of Main Window (WWN)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays details of a group that has been selected from the upper list.
(Displays nothing when no item to be selected exists in the upper list or
more than one item has been selected.)
Provided with a sorting function.
“WWN - Change...” menu Selectable when a single group has been selected from the lower list.
Displays the Change WWN window.
Pop-up menu Displays the “Change” menu when the right mouse button is clicked on
the item in the lower list.

Table 5.3.1.4-4-4 Details and Operation of Change WWN Window


Item Description
WWN To be used for entering a WWN (16 hexadecimal digits).
Nickname Used for entering a nickname (up to 64 characters).
Change all the same button In case of checking it, the change should be executed for the same
WWN including in the group of the other ports.
OK button Selectable only when the WWN has been entered correctly.
Closes the window after registering the WWN and nickname, and
returns you to the Main window.
Cancel button Returns you to the Main window without doing anything.

INST05-03-710
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-720

(4-3) Deleting WWN

Figure 5.3.1.4-4-5 Main Window

When “Port” in the tree view is selected, “Group” is set on the Display. Displays the group setting
in the port that has been selected in the upper right list. In the lower right list, details of a group that
has been selected from the upper right list are displayed.

Deletion of a WWN is done in the following procedure.


 Select (CL) a WWN you want to delete from the lower right list.
 Select (DR) [Delete] from the [WWN] menu in the Main window (Figure 5.3.1.4-4-5).
 Since a message asking for a confirmation is displayed, select (CL) the [Yes] button.
 The WWN that has been selected from the lower right list is deleted.

INST05-03-720
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-730

Table 5.3.1.4-4-5 Details and Operation of Main Window (Group)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays details of a group that has been selected from the upper list.
(Displays nothing when no item to be selected exists in the upper list or
more than one item has been selected.)
Provided with a sorting function.
“WWN - Delete” menu Selectable when a WWN has been selected from the lower list.
Displays a message asking for a confirmation.
Pop-up menu Displays “Delete” menu when the right mouse button is clicked on the
item in the upper list.

INST05-03-730
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-740

(4-4) Deleting WWN of the host linked DKC

Figure 5.3.1.4-4-6 Main Window

Figure 5.3.1.4-4-7
Login WWN List Window

Deletion of a WWN of the host linked to DKC is done in the following procedure.
 Select (DR) [Login List] from the [WWN] menu in the Main Window (Figure 5.3.1.4-4-6).
 Select (CL) the [Refresh] button on the ‘Login WWN List’ window (Figure 5.3.1.4-4-7) to
refresh the WWN list.
 Since the ‘Login WWN List’ window (Figure 5.3.1.4-4-7) is displayed, selected (CL) the
WWNs and select (CL) the [Delete] button.
 Select (CL) the [Close] button is close window returns you to the Main Window.

Table 5.3.1.4-4-6 Details and Operation Login WWN List window


Item Description
Port Specifies a port of the WWN to be displayed in the list.
When “All Port” is selected, all WWNs in the list are displayed.
List Displays a WWN list.
Delete button Deletes a selected WWN.
Refresh button Redraws the list.
Close button Returns you the Main window.

INST05-03-740
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-750

(5) Setting LUN


(5-1) Adding LUN

Figure 5.3.1.4-5-2 Add LUN Window

Figure 5.3.1.4-5-1 Main Window

When “Port” in the tree view is selected, “LUN” is set on the Display. Displays the group setting in
the port that has been selected in the upper right list. In the lower right list, details of a group that
has been selected from the upper right list are displayed.

Addition of a LUN is done in the following procedure.


 Change the Display to “LUN.”
 Select (CL) a group to which a LUN is to be added from the upper right list.
 Select (DR) [Add...] from the [LUN] menu in the Main window (Figure 5.3.1.4-5-1).
 Since the LUN Registration window (Figure 5.3.1.4-5-2) is displayed, select (CL) the LUN and
CU:LDEV and select (CL) the [SET] button. The LUN that has been set is displayed in the “Add
follows list.”
 When the [OK] button is selected (CL), items displayed in the “Add follows” list is newly
registered and the window is changed to the Main window (Figure 5.3.1.4-5-1).

Details of the Main Window (Figure 5.3.1.4-5-1) and the other windows are shown on the
following page.

INST05-03-750
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-760

Table 5.3.1.4-5-1 Details and Operation of Main Window (LUN)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays LUN’s defined as being contained in the group that has been
selected from the upper list.
(Displays nothing when no item to be selected exists in the upper list or
more than one item has been selected.)
NOTE: The following symbols may be added to LDKC:CU:LDEV #.
Each meaning is shown.
‘+’ : One LUN is set in other host groups.
‘++’ : Two or more LUNs are set in other host groups.
‘#’ : An external volume is shown.
‘V’ : A virtual volume for Thin Image is shown.
‘X’ : A Dynamic Provisioning volume is shown.
Provided with a sorting function.
“LUN - Add...” menu Selectable when a port subordinate to the LUN has been selected from
the tree.
Displays the Add LUN window.
Pop-up menu Displays the “Add” menu when the right mouse button is clicked on the
item in the upper list.

INST05-03-760
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-770

Table 5.3.1.4-5-2 Details and Operation of Add LUN Window


Item Description
Port Displays a name of a port that has been selected from the tree in the
Main window.
Port SLPR Displays the SLPR numbers related with the port.
Group list Displays all groups registered as being connected with the port
concerned.
LUN list Displays unused LUN’s in the group concerned according to the group
selection that has been made.
LDKC list Displays LDKC numbers of all mounted CU’s supported this function.
CU list Displays CU numbers of all mounted LDEV’s supported by this
function.
LDEV list Displays unused LDEV’s in the group concerned according to the group
selection that has been made.
NOTE: The following symbols may be added to LDKC:CU:LDEV #.
Each meaning is shown.
‘+’ : One LUN is set.
‘++’ : Two or more LUNs are set.
‘#’ : An external volume is shown.
‘V’ : A virtual volume for Thin Image is shown.
‘X’ : A Dynamic Provisioning volume is shown.
Add follows list Displays a LUN (path) to be added.
Set button Selectable only when the group, LUN, and CU:LDEV have been
selected.
The LUN that has been added is displayed in the “Add follows” list.
Delete button Excepts a LUN from LUNs to be added.
OK button Selectable only when the LUN’(s) is/are in the “Add follows” list.
Closes the window after adding the LUN and returns you to the Main
window.
Cancel button Closes the window without doing anything and returns you to the Main
window.

INST05-03-770
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-780

(5-2) Deleting LUN

Figure 5.3.1.4-5-3 Main Window

When “Port” in the tree view is selected, groups connected with the port that has been selected from
the tree are displayed in the upper right list. In the lower right list, details of a group that has been
selected from the upper right list are displayed.

Deletion of a LUN is done in the following procedure.


 Select (CL) a LUN from the upper right list.
 Select (DR) [Delete] from the [LUN] menu in the Main window (Figure 5.3.1.4-5-3).
 Since a message asking for a confirmation is displayed, select (CL) the [Yes] button.
 Information on the LUN that has been selected from the lower right list is deleted.

INST05-03-780
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-790

Table 5.3.1.4-5-3 Details and Operation of Main Window (LUN)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays LUNs defined for a group selected from the upper
list.(Displays nothing when no item to be selected exists in the upper list
or more than one item has been selected.)
NOTE: The following symbols may be added to LDKC:CU:LDEV #.
Each meaning is shown.
‘+’ : One LUN is set in other host groups.
‘++’ : Two or more LUNs are set in other host groups.
‘#’ : An external volume is shown.
‘V’ : A virtual volume for Thin Image is shown.
‘X’ : A Dynamic Provisioning volume is shown.
Provided with a sorting function.
“LUN - Delete...” menu Selectable when a LUN has been selected from the lower list.
Displays a message asking for a confirmation.
Pop-up menu Displays “Delete” menu when the right mouse button is clicked on the
item in the lower list.

INST05-03-790
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-800

(5-3) Changing Command Device from the LUN list

Figure 5.3.1.4-5-4 Main Window Figure 5.3.1.4-5-5


Command Device Window

When “Port” in the tree view is selected, groups connected with the port that has been selected from
the tree are displayed in the upper right list. In the lower right list, details of a group that has been
selected from the upper right list are displayed.

Setting of a Command Device from the LUN list is made in the following procedure.
 Select (CL) LUN from the lower right list.
 Select (DR) [Command Device] from the [LUN] menu in the Main window (Figure 5.3.1.4-5-4).
 Change “Command Device” in the ‘Command Devices’ window (Figure 5.3.1.4-5-5), and select
(CL) the [OK] button.
 Information on the LUN that has been selected from the lower right list is reflected.

When changing the command device from the LDEV list, refer to page INST05-03-850.

NOTE: ‘On*’ shows the remote command device.


It is possible to change for the remote command device.

INST05-03-800
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-810

Table 5.3.1.4-5-4 Details and Operation of Main Window (LUN)


Item Description
Upper list Displays groups connected with the port that has been selected from the
tree.
Provided with a sorting function.
Lower list Displays LUN’s defined as being contained in the group that has been
selected from the upper list. (Displays nothing when no item to be
selected exists in the upper list or more than one item has been selected)
NOTE: The following symbols may be added to LDKC:CU:LDEV#.
Each meaning is shown.
‘+’ : One LUN is set in other host groups.
‘++’ : Two or more LUNs are set in other host groups.
‘#’ : An external volume is shown.
‘V’ : A virtual volume for Thin Image is shown.
‘X’ : A Dynamic Provisioning volume is shown.
Provided with a sorting function.
“LUN - Command Device...” Selectable when a LUN has been selected from the lower list.
menu
Displays the Command Device window.
Pop-up menu Displays the “Command Device” menu when the right mouse button is
clicked on the item in the lower list.

Table 5.3.1.4-5-5 Details and Operation of Add LUN Window


Item Description
Command Device Displays the command device of LUN selection.
When it is checked, the command device is on.
Command Device Security Displays a status of command device security of the LUN that has been
selected.
Checkable only when [Command Device] is on.
When it is checked, the security of the command device is on.
User Authentication When it is checked, the authentication command device is validated.
Checkable only when [Command Device] is on.
Device Group Definition When it is checked, the Device Group Definition device is validated.
Checkable only when [Command Device] is on.
OK button Closes the window after changing the parameter and returns you to the
Main window.
Cancel button Closes the window without doing anything and returns you to the Main
window.

INST05-03-810
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-820

(6) Changing Port

Figure 5.3.1.4-6-1 Main Window

Figure 5.3.1.4-6-2
Port Parameter Window

When “Port” in the tree view is selected (CL), installed ports supported by this function are
displayed in the upper right list.

A change of a Port Parameter is made in the following procedure.


 Select (CL) a port from the upper right list.
 Select (DR) [Parameter...] from the [Port] menu in the Main window (Figure 5.3.1.4-6-1).
 Since the Port Parameter window (Figure 5.3.1.4-6-2) is displayed, set each item and select (CL)
the [OK] button.
 You can change information on the port that has been selected from the upper right list.

INST05-03-820
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-830

Table 5.3.1.4-6-1 Details and Operation of Main Window (Port)


Item Description
Upper list Displays installed ports supported by this function.
Provided with a sorting function.
Lower list Displays no item.
“Port - Parameter...” menu Selectable when a port has been selected from the upper list.
Displays the Port Parameter window.
Pop-up menu Displays the “Parameter...” menu when the right mouse button is
clicked on the item in the upper list.

Table 5.3.1.4-6-2 Details and Operation of Port Parameter Window


Item Description
AL-PA Displays an AL-PA value of a fibre port address.
Loop ID Displays a loop ID value of a fibre port address.
Fabric Displays whether to use (On) or not to use (Off) the fabric
Connection Displays which is to be used: FC-AL or Point to Point.
Channel Speed Displays 2[Gbps], 4[Gbps], 8[Gbps], Auto or 4[Gbps], 8[Gbps],
16[Gbps], Auto according to the CHA PCB type.
OK button Closes the window after changing the parameter(s), and returns you to
the Main window.
Cancel button Returns you to the Main window without doing anything.

NOTE: When a 16G FC CHA is used, choose “Point to Point” in the [Connection] radio
button to make all the [Channel Speed] options selectable.
If you choose “FC_AL” in [Connection], “16[Gbps]” option in [Channel Speed] is not
selectable.

INST05-03-830
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-840

Fibre port addresses (AL-PA’s and loop ID’s) are shown below.

Table 5.3.1.4-6-3 Fibre Port Addresses (AL-PA’s and Loop ID’s)


AL Loop AL Loop AL Loop AL Loop AL Loop AL Loop AL Loop AL Loop
AP ID AP ID AP ID AP ID AP ID AP ID AP ID AP ID
EF 0 CD 16 B2 32 98 48 72 64 55 80 3A 96 25 112
E8 1 CC 17 B1 33 97 49 71 65 54 81 39 97 23 113
E4 2 CB 18 AE 34 90 50 6E 66 53 82 36 98 1F 114
E2 3 CA 19 AD 35 8F 51 6D 67 52 83 35 99 1E 115
E1 4 C9 20 AC 36 88 52 6C 68 51 84 34 100 1D 116
E0 5 C7 21 AB 37 84 53 6B 69 4E 85 33 101 1B 117
DC 6 C6 22 AA 38 82 54 6A 70 4D 86 32 102 18 118
DA 7 C5 23 A9 39 81 55 69 71 4C 87 31 103 17 119
D9 8 C3 24 A7 40 80 56 67 72 4B 88 2E 104 10 120
D6 9 BC 25 A6 41 7C 57 66 73 4A 89 2D 105 0F 121
D5 10 BA 26 A5 42 7A 58 65 74 49 90 2C 106 08 122
D4 11 B9 27 A3 43 79 59 63 75 47 91 2B 107 04 123
D3 12 B6 28 9F 44 76 60 5C 76 46 92 2A 108 02 124
D2 13 B5 29 9E 45 75 61 5A 77 45 93 29 109 01 125
D1 14 B4 30 9D 46 74 62 59 78 43 94 27 110
CE 15 B3 31 9B 47 73 63 56 79 3C 95 26 111

INST05-03-840
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-850

(7) LDEV List


(7-1) Changing Command Device from LDEV list

Figure 5.3.1.4-7-1 Main Window

Figure 5.3.1.4-7-2
Command Device Window

When “Logical Device-LDKC#00” in the tree view is selected (CL), CU numbers of installed
LDEV’s supported by this function are displayed in the upper right list. In the lower right list,
details of a CU selected from the upper right list are displayed.

A change of a command device is made in the following procedure.


 Select (CL) an LDEV you want to change from the lower right list.
 Select (DR) [Change...] from the [Device] menu in the Main window (Figure 5.3.1.4-7-1).
 Since the Command Device window (Figure 5.3.1.4-7-2) is displayed, change the “Command
Device” and select (CL) the [OK] button.
 Information that has been set is reflected in the LDEV that has been selected from the lower
right list.

NOTE: ‘On*’ shows the remote command device.


It is not possible to change for the remote command device.

INST05-03-850
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-860

Table 5.3.1.4-7-1 Details and Operation of Main Window (Command Device)


Item Description
Upper list Displays CU numbers of installed LDEV’s supported by this function.
Provided with a sorting function.
Lower list Displays details of a CU selected from the upper list. (Displays nothing
when no item to be selected exists in the upper list or more than one
item has been selected)
NOTE: The following symbols may be added to LDEV#. Each meaning
is shown.
‘#’ : An external volume is shown.
‘V’ : A virtual volume for Thin Image is shown.
‘X’ : A Dynamic Provisioning volume is shown.
Provided with a sorting function.
“LDEV - Command Device...” Selectable only when an LDEV that is given a definition of LUN has
menu been selected from the lower list.
Displays the Command Device window.
Pop-up menu Displays the “Command Device...” menu when the right mouse button
is clicked on the item in the lower list.

Table 5.3.1.4-7-2 Details and Operation of Command Device Window


Item Description
Command Device Displays a status of a command device of the LDEV that has been
elected.
When it is checked, the command device is on.
Command Device Security Displays a status of command device security of the LDEV that has
been selected.
Checkable only when [Command Device] is on.
When it is checked, the command device security is on.
User Authentication When it is checked, the authentication command device is validated.
Checkable only when [Command Device] is on.
Device Group Definition When it is checked, the Device Group Definition device is validated.
Checkable only when [Command Device] is on.
OK Button Closes the window after changing the parameters, and returns you to the
Main window.
Cancel Button Returns you to the Main window without doing anything.

INST05-03-860
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-870

(7-2) Deleting LUN from LDEV

Figure 5.3.1.4-7-3 Main Window

Figure 5.3.1.4-7-4
Alternate LUN Window

When “Logical Device-LDKC#00” is selected (CL) from the tree, CU numbers of the installed
LDEV conforming to this function are displayed in the upper right list. In the lower right list, detail
of the CU selected from the upper right list is displayed.

Deletion of a LUN from the LDEV list is to be done in the following procedure.
 Select (CL) a single LDEV to which you want to refer for the set information on the LUN from
the lower right list.
 Select (DR) [Alternate] from the [LDEV] menu in the main window (Figure 5.3.1.4-7-1).
 Select the LUN you want to delete from the list in the Alternate window (Figure 5.3.1.4-7-2) and
select (CL) the [Delete] button.
 Since a message asking for a confirmation is displayed, select (CL) the [Yes] button.
 When the [Close] button is selected (CL) in the Alternate window (Figure 5.3.1.4-7-2), the
window is returned to the main window (Figure 5.3.1.4-7-1).

INST05-03-870
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-880

Table 5.3.1.4-7-3 Detail and Operation of Main Window (Logical Device)


Item Description
Upper list Displays CU numbers of the installed LDEV conforming to this
function.
This list has a sorting function.
Lower list Displays detail of the CU selected from the upper list.
(Nothing is displayed when no CU has been selected or two or more
CUs have been selected.)
NOTE: The following symbols may be added to LDEV #. Each
meaning is shown.
‘#’ : An external volume is shown.
‘V’ : A virtual volume for Thin Image is shown.
‘X’ : A Dynamic Provisioning volume is shown.
This list has a sorting function.
“Device - Alternate LUN” menu This menu is selectable only when a single LDEV has been selected
from the lower list.
Displays the Alternate LUN window.
Pop-up menu Displays the “Alternate LUN” menu when an item in the lower list is
clicked by the right mouse button.

Table 5.3.1.4-7-4 Detail and Operation of Alternate LUN Window


Item Description
Port combo box Specify a port you want to display in the LUN list. When All Port is
specified, all ports of the LUN are displayed in the LUN list.
LDKC:CU:LDEV Displays the LDKC:CU:LDEV selected.
LUN list Displays LUNs assigned to the LDEV concerned.
Delete button Deletes the LUN that as been selected from the list.
Close button Closes the window and you return to the Main window.

INST05-03-880
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-890

(8) Closing LUN Management Window


When closing ‘LUN Management’ window, a message “Are you sure you want to complete
this function?” is displayed.

Define Configuration : Go to (8)-1


Refer Configuration : Go to (8)-2
Change Configuration : Go to (8)-3

(8)-1 Define Configuration


If you want to apply and finish this function,
select [Yes].
If you don’t want to apply and finish this
function, select [No].
If you close this message, select [Cancel].

(8)-2 Refer Configuration


If you want to complete this function, select
[Yes].
If you don’t want to complete this function,
select [No].
If you close this message, select [Cancel].

(8)-3 Change Configuration


If you want to complete this function, select
[OK].
If you close this message, select [Cancel].

INST05-03-890
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-900

5.3.2 Emulation Type Change

1. <Mode Change>
Change the mode to Modify Mode.
Select (CL) [Install].

2. <Start the ‘Menu Dialog’ screen>


Select (CL) [Change Configuration].

3. <Start Device Structure Setup screen>


Select (CL) [DKU Emulation] in the ‘Menu
Dialog’ dialog box and select (CL) [OK].

INST05-03-900
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-910

4. <Input password>

CAUTION
This is a special (exceptional) operation that can cause a serious failure such as a
system down or a data loss if a wrong drive for which the emulation type is to be changed
is selected, and requires an input of a password. Ask the technical support division about
the appropriateness of the operation, and input the password after getting an approval of
executing the operation.

Enter the password and select (CL) [OK].

INST05-03-910
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-920

5. Emulation Change Procedure


• Emulation Type Change for Single Block -------------------------- Go to Step 5-1.
• Emulation Type Change for Single LDEV ------------------------- Go to Step 5-2.
• Emulation Type Change for Multiple Blocks ---------------------- Go to Step 5-3.
• Individual Emulation Type Change for Multiple LDEVs -------- Go to Step 5-4.
NOTE: When operator tries to change from normal volume to Cross-OS File Exchange
volume, operator must clear ALIAS definition if current volume has ALIAS provided
by PAV function.

5-1 Emulation Type Change for Single Block


(1)
Select (CL) a block including an LDEV of which you want to
change the emulation type in the LDEV Emulation (32 ID
Block) list box.

(2)
Select (CL) [change] beneath the LDEV
Emulation (32 ID Block) list box to open the
dialog box for (choosing) the emulation type
to be changed, and select (CL) the changed
emulation type.

When a block including an LDEV with the


SCSI path (which is indicated with “+” in the
list box) is selected, the [change] button is
disabled.

(3)
Select (CL) [OK] to set the changed emulation type.
Then, the LDEV (selected in Step (1)) having the emulation
type to be changed varies to the one specified in Step (2).
When selecting the same LDEV block after setting the
change, you can check details of the changes in the LDEV
Emulation (Detail) list box. Go to Step 6.

INST05-03-920
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-930

5-2 Emulation Type Change for Single LDEV


(1)
Select (CL) a block including an LDEV of which you want to
change the emulation type in the LDEV Emulation (32 ID
Block) list box.

(2)
In the LDEV Emulation (Detail) list box, select (CL) an LDEV whose emulation type to be
changed.

(3)
Select (CL) [change] beneath the LDEV
Emulation (Detail) list box to open the dialog
box for (choosing) the emulation type to be
changed, and select (CL) the changed
emulation type.

When a block including an LDEV with the


SCSI path (which is indicated with “+” in the
list box) is selected, the [change] button is
disabled.

(4)
Select (CL) [OK] to set the changed emulation type.
Then, the LDEV (selected in step (2)) varies to the one
specified in Step (3). Go to Step 6.

INST05-03-930
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-940

5-3 Emulation Type Change for Multiple Blocks


(1)
Select (CL) blocks including an LDEV of which you want to
change the emulation type in the LDEV Emulation (32 ID
Block) list box.

(2)
Select (CL) [change] beneath the LDEV
Emulation (32 ID Block) list box to open the
dialog box for (choosing) the emulation type
to be changed, and select (CL) the changed
emulation type.

When a block including an LDEV with the


SCSI path (which is indicated with “+” in the
list box) is selected, the [change] button is
disabled.

(3)
Select (CL) [OK] to set the changed emulation type.
Then, the LDEV (selected in Step (1)) having the emulation
type to be changed varies to the one specified in Step (2).
When selecting the same LDEV block after setting the
change, you can check details of the changes in the emulation
LDEV Emulation (Detail) list box. Go to Step 6.

INST05-03-940
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-950

5-4 Individual Emulation Type Change for Multiple LDEVs


(1)
Select (CL) a block including LDEVs of which you want to
change the emulation type in the LDEV Emulation (32 ID
Block) list box.

(2)
In the LDEV Emulation (Detail) list box, select (CL) LDEVs whose emulation types are to be
changed.

(3)
Select (CL) [change] beneath the LDEV
Emulation (Detail) list box to open the dialog
box for (choosing) the emulation type to be
changed, and select (CL) the changed
emulation type.

When a block including an LDEV with the


SCSI path (which is indicated with “+” in the
list box) is selected, the [change] button is
disabled.

(4)
Select (CL) [OK] to set the changed emulation type.
Then, the LDEV (selected in Step (2)) varies to the one
specified in step (3). Go to Step 6.

INST05-03-950
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-960

6.
Select (CL) [OK] to fix the emulation type change.
Select (CL) [Cancel] to cancel the operation.

7.
Before changing the emulation type, make
sure that the drive has already been set to
Vary Off-line and that the host concerned has
been shut down, and then select (CL) [OK].

When [Cancel] is selected (CL), the


processing is aborted.

8.
“Changing DKU Emulation” is displayed.

9. <Drive Vary On-line>


When the emulation type change processing
terminates normally, the message “Change
emulation type is normal end. Please vary the
drives on-line.” is displayed.
Vary the drive on-line and select (CL) [OK].

INST05-03-960
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-970

10.
Execute an operation for backing up the
configuration information.
Prepare the removable media for backup and
insert the media.
Please select (CL) the [Refresh] button, and
update drive information.
Select (CL) the drive and the PC in which the
media was inserted. Select (CL) the [OK]
button.
NOTE: For the procedure of backing up the
configuration information to a CD-R,
see page MICRO07-190.

11.
When this procedure is completed, the message
“Please remove the Config media.” is displayed.
Remove the configuration information media,
select (CL) [OK].

12.
After the procedure is completed, return to
‘Install’.
Select (CL) [File]-[Exit].

13. <Mode Change>


Change the Mode from [Modify Mode] to [View Mode].

INST05-03-970
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-03-980

14.
In SVP, select (CL) [Execute]-[Exit].
Please select (CL) [File]-[Refresh All] from
the menu and update the information on the
Web Console window when the Web Console
window is displayed.

INST05-03-980
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-04-10

5.4 Procedure for connecting external servers


The following describes the procedure for connecting external servers (eg. Authentication Server,
Key Management Server) with SVP.

1. Connect SVP by remote desktop.

2. Configure DNS Setting of SVP.

5.4.1 Connect SVP by remote desktop


Connect to SVP from Maintenance PC.

Prerequisite
• It should be performed by a user who belongs to the Support Personnel Group.

Operation procedure
1.
In Maintenance PC, select (DR) [Start]-[All Programs]-[Accessories]-[Remote Desktop
Connection] to start the remote desktop connection.

2.
Enter the IP address of SVP in [Computer].

3.
Select (CL) [Local Resources] tab.

INST05-04-10
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-04-20

4.
Select (CL) [More...].

5.
Select (CL) [Drives] and [OK].

6.
Select (CL) [Connect]. The login window appears.

7.
Enter the user name and the password to log into SVP.

INST05-04-20
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-04-30

5.4.2 Configure DNS Setting of SVP


DNS setting of SVP is required for connecting external servers.

Prerequisite
• It should be performed by a user who belongs to the Support Personnel Group.

Operation procedure

1. Opening the Control Panel window


Select (DR) [Control Panel] from the [Start] menu.

2. Opening the Network and Sharing Center window


Double-click [Network and Sharing Center] in the ‘Control Panel’ window.

INST05-04-30
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-04-40

3. Opening the Manage network connections window


Select (CL) [Change adapter settings] in the left side of ‘Network and Sharing Center’ window.

4. Opening the Public LAN Properties window


Select (CL) [Public LAN] in the ‘Network Connections’ window and select (CL) [Properties]
by clicking the right mouse button.

INST05-04-40
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-04-50

5. Opening the Internet Protocol Version 4 (TCP/IPv4) Properties window


Select (CL) [Internet Protocol Version 4 (TCP/IPv4)] in the ‘Public LAN Properties’ window
and select (CL) the [Properties] button.

6. Setting the external IP address


Set the “Preferred DNS server” and “Alternate DNS server” and select (CL) the [OK] button.
When you do not set IPv6, go to Step 9.

INST05-04-50
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-04-60

7. Opening the Internet Protocol Version 6 (TCP/IPv6) Properties window


Select (CL) [Internet Protocol Version 6 (TCP/IPv6)] in the ‘Public LAN Properties’ window
and select (CL) the [Properties] button.

8. Setting the external IP address


Set the “Preferred DNS server” and “Alternate DNS server” and select (CL) the [OK] button.

9. Closing the window


After the setting is completed, select (CL) the [OK] button in the “Public LAN Properties”
window.
INST05-04-60
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST05-05-10

5.5 Switch the Auto Account Lock Function


For the purpose of avoiding password brute force attack, if login to Storage Navigator and SVP
failed three times in a row, the account is locked for 60 seconds, and then a message indicating the
authentication failure is output.
This section describes the procedure for switching from this function to the method that disables the
account when login fails for the specified number of times, and the procedure for switching to the
function again.

(1) Procedure for switching to the account disabling function

1. In SVP, select (DR) [Start]-[Run], enter the following command, and select (CL) [OK] to
run the batch file.
“setAccountLock_UnlockedByAdmin X”

X: Specify a numerical value from 1 to 32 as the number of times login fails until the
account is disabled.

2. After the batch file ended normally, the message “All process completed.” appears.
If it ends abnormally, the following message is output. Check the parameter.
“Parameter is invalid.
Confirm the execution parameter and try again.”
NOTE: If all accounts registered to SVP are disabled, you cannot log into SVP
(Authentication can be done in the authentication server).
Prevent all accounts from being disabled.

(2) Procedure for switching to the account lock function

1. In SVP, select (DR) [Start]-[Run], enter the following command, and select (CL) [OK] to
run the batch file.
“setAccountLock_UnlockedByTimer”

2. After the batch file ended normally, the message “All process completed.” appears.
If it ends abnormally, the following message is output. Check the extra parameter.
“Parameter is invalid.
Confirm the execution parameter and try again.”

INST05-05-10
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-10

6. Storage Capacity and Cache Capacity, and the number of required


options
6.1 Required CM Capacity
(1) SM Capacity
Required shared memory capacity is determined by the number of LDEV and the kind of
program product to apply. Required shared memory capacity is determined with reference to
the table indicated at the Table 6.1-1.

Table 6.1-1 Reference Table Shared Memory Capacity (1/2)


Judgment Factor of SM Capacity (*3)
Number of Program Product (*1) DP/HDT/TI
SI/VM SM
No. CU Extension
Extension Capacity
(Configuration SI/VM DP/TI/ TPF TC/
HDT (*5)
FC HUR (*6)
of LDEV) 1 2 3
1-64
1          16GB
(16KLDEV)
1-64
2          24GB
(16KLDEV)
1-64
3          24GB
(16KLDEV)
1-64
4          24GB
(16KLDEV)
1-255
5          24GB
(64KLDEV)
1-64
6          32GB
(16KLDEV)
1-64
7          32GB
(16KLDEV)
1-64
8          32GB
(16KLDEV)
1-255
9          32GB
(64KLDEV)
1-255
10          32GB
(64KLDEV)
1-255
11          32GB
(64KLDEV)
1-64
12          40GB
(16KLDEV)
1-64
13          40GB
(16KLDEV)
1-255
14          40GB
(64KLDEV)
1-255
15          40GB
(64KLDEV)
1-255
16          40GB
(64KLDEV)

INST06-10
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-20

Table 6.1-1 Reference Table Shared Memory Capacity (2/2)


Judgment Factor of SM Capacity (*3)
Number of Program Product (*1) DP/HDT/TI
SI/VM SM
No. CU Extension
DP/TI/ TC/ Extension Capacity
(Configuration SI/VM TPF HDT (*5)
FC HUR (*6)
of LDEV) 1 2 3
1-64
17          48GB
(16KLDEV)
1-64
18          48GB
(16KLDEV)
1-255
19          48GB
(64KLDEV)
1-255
20          48GB
(64KLDEV)
1-64
21          56GB
(16KLDEV)
1-64
22          56GB
(16KLDEV)
1-255
23          56GB
(64KLDEV)
1-255
24          56GB
(64KLDEV)
1-64
25          64GB
(16KLDEV)
1-64
26          64GB
(16KLDEV)
1-255
27          64GB
(64KLDEV)
1-255
28          64GB
(64KLDEV)
1-64
29          72GB
(16KLDEV)
1-255
30          72GB
(64KLDEV)
1-255
31          72GB
(64KLDEV)
1-255
32          80GB
(64KLDEV)

*1: Program Product


SI : ShadowImage/ VM : Volume Migration (*2)
ShadowImage for Mainframe
DP : Dynamic Provisioning TI : Thin Image
FC : FlashCopy (R) TPF : Transaction Processing Facility
TC : TrueCopy/ HUR : Universal Replicator/
TrueCopy for Mainframe Universal Replicator for Mainframe
HDT : Dynamic Tiering
*2: Volume Migration is a function in Hitachi Tiered Storage Manager.

INST06-20
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-30

*3: Marks used in the columns of Judgment Factor of SM Capacity means as follows.
 (N?): Functions and Program Products described in the table are not available as the
SM used by the functions and the Program Product is ineffective.
 (Y?): Functions and Program Products described in the table are available as the SM
used by the functions and Program Products is effective. (To use the Program
Products, performing installation operation separately is required (*4))
*4: For installation operation, refer to “Hitachi Device Manager - Storage Navigator User
Guide”.
*5: When Dynamic Provisioning/Dynamic Provisioning for Mainframe/Thin Image/
Dynamic Tiering/Dynamic Tiering for Mainframe is used, pool/virtual volume capacity
that can be made according to the increase situation of a shared memory is enhanced.
When using it exceeding the capacity of pool/ virtual volume of 1.1PB (OPEN) or 1.0PB
(MF), it is necessary to increase DP/HDT/TI Extension.
When DP/HDT/TI Extension is decreased, it is necessary to delete all DP, HDT and TI
pools.

Table 6.1-2 Pool / Virtual volume Capacity of SM of available


Program Product OPEN Mainframe
DP ~ 1.1PB ~ 1.0PB
DP/HDT/TI Extension1 ~ 3.4PB ~ 3.0PB
DP/HDT/TI Extension2 ~ 7.9PB ~ 7.1PB
DP/HDT/TI Extension3 ~ 12.3PB ~ 11.0PB

*6: When using ShadowImage/ShadowImage for Mainframe/VolumeMigration, select either


[Base] or [Extension].
The differences between [Base] and [Extension] are as follows:
When creating a pair of ShadowImage or ShadowImage for Mainframe, or creating
shifting plan of Volume Migration, resources called a difference table and a pair table is
required. When selecting [Extension], more resources become available than selecting
[Base], which allows creating more pairs or shifting plan.
The number of pairs that can be created in the ShadowImage or ShadowImage for
Mainframe, see THEORY SECTION “3.9 ShadowImage for Mainframe &
ShadowImage”
(THEORY03-09-10).
For details of shift plan number on Volume Migration to be created, see THEORY
SECTION “3.11 Volume Migration” (THEORY03-11-10).

INST06-30
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-40

The following table shows the correspondence of items shown in the ‘SVP’ window and those
in the Reference Table. Set the SM in the ‘SVP’ window based on the table below.

Table 6.1-3 SVP Window and those in the Reference Table


SVP Window
No. Reference Table
Item Check box
1 64KLDEV, SI/VM Extension, TPF OFF Number of CU: 65-255, SI/VM
Extension, TPF function not applied
ON Number of CU: 65-255, SI/VM
Extension, TPF function applied
2 TC/HUR OFF TC/HUR function not applied
ON TC/HUR function applied
3 HDT OFF HDT function not applied
ON HDT function applied
4 DP/HDT/TI Extension1 OFF DP/HDT/TI Extension1 function not
applied
ON DP/HDT/TI Extension1 function
applied
5 DP/HDT/TI Extension2 OFF DP/HDT/TI Extension2 function not
applied
ON DP/HDT/TI Extension2 function
applied
6 DP/HDT/TI Extension3 OFF DP/HDT/TI Extension3 function not
applied
ON DP/HDT/TI Extension3 function
applied

INST06-40
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-50

(2) Cache Capacity


The cache capacity of VSP G1000 is determined by the number of installed MPB, the RAID
level, the drives installed in the disk array system, whether Dynamic Provisioning
(DP)/Dynamic Tiering (HDT)/Dynamic Cache Residency (DCR)/Extend Remote Copy
(XRC)/Universal Volume Manager (UVM) is applied/not applied etc.
The required cache capacity installed in VSP G1000 depends on the number of MPB as shown
in the following table.

Table 6.1-4 Relation between the number of MPB and the required cache memory
capacity
Number of MPB Required cache capacity (*1)
2 8GB or more (*2)
4 16GB or more
6 24GB or more
8 32GB or more
10 40GB or more
12 48GB or more
14 56GB or more
16 64GB or more

*1: The sum of data cache capacity and cache directory capacity
*2: 1GB = 1,0243Byte

The recommended cache capacity is determined by the number of installed MPB, the drives
installed in the disk array system, whether DP/HDT/DCR/XRC/UVM is applied/not applied
etc. The calculation process of the recommended data cache capacity is shown below.

The recommended data cache capacity per CLPR =


(CLPR capacity – DCR Extent setting capacity per CLPR)

INST06-50
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-60

(i) In case of CLPR to which DP/HDT/DCR/XRC is not applied


Install the recommended data cache capacity (or more) shown in the table below.

Table 6.1-5 Recommended data cache capacity in case DP/HDT/DCR/XRC is not


applied
Total logical capacity of Recommended data cache capacity per CLPR
External volumes + Number Number Number Number Number Number Number Number
Internal volumes per of MPB of MPB of MPB of MPB of MPB of MPB of MPB of MPB
CLPR 2 4 6 8 10 12 14 16
Less than 4TB 8GB 12GB 20GB 28GB 36GB 44GB 52GB 60GB
4TB or more 16GB 16GB 20GB 28GB 36GB 44GB 52GB 60GB
16TB or more 24GB 24GB 24GB 28GB 36GB 44GB 52GB 60GB
48TB or more 32GB 32GB 32GB 32GB 36GB 44GB 52GB 60GB
96TB or more 40GB 40GB 40GB 40GB 40GB 44GB 52GB 60GB
160TB or more 48GB 48GB 48GB 48GB 48GB 48GB 52GB 60GB
240TB or more 56GB 56GB 56GB 56GB 56GB 56GB 56GB 60GB
360TB or more 64GB 64GB 64GB 64GB 64GB 64GB 64GB 64GB
600TB or more 72GB 72GB 72GB 72GB 72GB 72GB 72GB 72GB

INST06-60
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-70

(ii) In case of CLPR to which DP or HDT is applied


Install the recommended data cache capacity (or more) shown in the table below.

Table 6.1-6 Recommended data cache capacity in case DP or HDT is applied


Total logical capacity of Recommended data cache capacity per CLPR
External volumes + Number Number Number Number Number Number Number Number
Internal volumes per of MPB of MPB of MPB of MPB of MPB of MPB of MPB of MPB
CLPR 2 4 6 8 10 12 14 16
Less than 4TB 12GB 20GB 28GB 36GB 44GB 52GB 60GB 68GB
4TB or more 16GB 20GB 28GB 36GB 44GB 52GB 60GB 68GB
16TB or more 24GB 24GB 28GB 36GB 44GB 52GB 60GB 68GB
48TB or more 32GB 32GB 32GB 36GB 44GB 52GB 60GB 68GB
96TB or more 40GB 40GB 40GB 40GB 44GB 52GB 60GB 68GB
160TB or more 48GB 48GB 48GB 48GB 48GB 52GB 60GB 68GB
240TB or more 56GB 56GB 56GB 56GB 56GB 56GB 60GB 68GB
360TB or more 64GB 64GB 64GB 64GB 64GB 64GB 64GB 68GB
600TB or more 72GB 72GB 72GB 72GB 72GB 72GB 72GB 72GB

INST06-70
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-80

(iii) In case of CLPR to which DCR is applied


It is recommended to install cache capacity according to the number of areas to which the
Priority mode of DCR Extent setting is applied. The purpose is to avoid the possible access
performance degradation of non-DCR data when DCR is set. In other words, if data is
written to the area to which the Priority mode is applied, the data is written to the cache
(standard cache) other than the DCR cache. If data is written to the area to which the
Priority mode is applied while the standard cache is overloaded (available cache capacity is
small), there would be no available capacity in the standard cache, and wait for available
standard cache would occur frequently. Consequently access performance of non-DCR
data could be degraded.
If the recommended data cache capacity shown in the following table is larger than the
recommended data cache capacities calculated in (i) and (ii), install the recommended data
cache capacity shown in the following table.

Table 6.1-7 Recommended data cache capacity in case DCR Priority mode is
applied
Settings of priority mode Recommended data cache capacity per
CLPR
The specified number of cache extents is 8,192 or less and 16GB or more
the specified capacity is 128 GB or less.
The specified number of cache extents exceeds 8,192 or 32GB or more
the specified capacity exceeds 128 GB.

(iv) In case of CLPR to which XRC is applied


CLPR to which XRC is applied uses cache for the management information called sidefile.
Therefore it is recommended install larger capacity than the recommended data cache
capacity calculated in (i) through (iii) by taking “the level-1 threshold” of XRC into
account. Use the following formula to calculate it.

Recommended data cache capacity ≥


(Recommended data cache capacity calculated in (i) through (iii))  100  (100 − (the
level-1 threshold))

INST06-80
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-90

(v) In case of CLPR for UVM


If the configuration of the CLPR meets the conditions described in Table 6.1-8, you can
apply the recommended data cache capacity shown in Table 6.1-9.

Table 6.1-8 CLPR for UVM


Conditions of CLPR for UVM
• One CLPR consists of only external volumes
• Performance is not important
• The cache mode of the mapped volumes is “Disable”
• It consists of only volumes for open systems

Table 6.1-9 Recommended cache memory capacity of CLPR for UVM


Total logical capacity of external Number of MPB Recommended cache capacity of
volumes in CLPR for UVM CLPR for UVM
Less than 128TB 2/4/6/8 8GB
10/12 12GB
14/16 16GB
128TB or more 2/4 8GB
6 12GB
8 16GB
10 20GB
12 24GB
14 28GB
16 32GB

INST06-90
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-100

(3) Total CM Capacity


Required total CM capacity is determined by the sum of SM capacity, data cache memory
(data CM) capacity and cache directory (cache DIR) capacity.
Cache DIR capacity is determined by the amount of memory installed in the CPEX. The
relation between cache DIR capacity and data CM capacity is shown in Table 6.1-10 to Table
6.1-12.

Table 6.1-10 Reference Table for Cache DIR Capacity and Data CM Capacity
(CPEX0)
CM16G CM32G Cache Directory Capacity (GB) Data CM Capacity (GB)
2 0 1 31 – SM Capacity
4 0 1.25 62.75 – SM Capacity
6 0 1.5 94.5 – SM Capacity
8 0 1.75 126.25 – SM Capacity
10 0 2 158 – SM Capacity
12 0 2.25 189.75 – SM Capacity
14 0 2.5 221.5 – SM Capacity
16 0 2.75 253.25 – SM Capacity
0 2 1 63 – SM Capacity
0 4 1.25 126.75 – SM Capacity
0 6 1.5 190.5 – SM Capacity
0 8 1.75 254.25 – SM Capacity
0 10 2 318 – SM Capacity
0 12 2.25 381.75 – SM Capacity
0 14 2.5 445.5 – SM Capacity
0 16 2.75 509.25 – SM Capacity

INST06-100
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-110

Table 6.1-11 Reference Table for Cache DIR Capacity and Data CM Capacity
(CPEX1)
CM16G CM32G Cache Directory Capacity (GB) Data CM Capacity (GB)
2 0 1 31
4 0 1.25 62.75
6 0 1.5 94.5
8 0 1.75 126.25
10 0 2 158
12 0 2.25 189.75
14 0 2.5 221.5
16 0 2.75 253.25
0 2 1 63
0 4 1.25 126.75
0 6 1.5 190.5
0 8 1.75 254.25
0 10 2 318
0 12 2.25 381.75
0 14 2.5 445.5
0 16 2.75 509.25

INST06-110
Hitachi Proprietary DKC810I
Rev.0 / Dec.2013 Copyright © 2013, Hitachi, Ltd.
INST06-120

Table 6.1-12 Reference Table for Cache DIR Capacity and Data CM Capacity
(CPEX2/CPEX3)
CM16G CM32G Cache Directory Capacity (GB) Data CM Capacity (GB)
2 0 0.5 31.5
4 0 0.75 63.25
6 0 1 95
8 0 1.25 126.75
10 0 1.5 158.5
12 0 1.75 190.25
14 0 2 222
16 0 2.25 253.75
0 2 0.5 63 .5
0 4 0.75 127.25
0 6 1 191
0 8 1.25 254.75
0 10 1.5 318.5
0 12 1.75 382.25
0 14 2 446
0 16 2.25 509.75

When multiple CPEXs are installed, a configuration in which data CM capacity is distributed
as evenly as possible to each CPEX is recommended. CPEX0 requires more cache memory
capacity than other CPEXs because SM capacity is included in CPEX0.

INST06-120