max.
Specifications
Ratings
Rated voltage Resistive load
125 VAC 5A
250 VAC 3A
Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min.
140
K K
Characteristics
Operating speed 0.1 mm to 1 m/s (pin plunger models)
Operating frequency Mechanical: 300 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) 30 mΩ max.
Dielectric strength (see note 2) 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarities
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between
each terminal and non-current-carrying metal part
Vibration resistance (see note 3) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (see note 3) Destruction: 500 m/s2 {approx. 50G} max.
Malfunction: 300 m/s2 {approx. 30G} max.
Durability (see note 4) Mechanical: 20,000,000 operations min. (60 operations/min) (Refer to Engineering Data.)
Electrical: 100,000 operations min. (30 operations/min) (Refer to Engineering Data.)
Degree of protection IEC IP40
Degree of protection against Class I
electric shock
Proof tracking index (PTI) 175
Ambient operating temperature –25°C to 80°C (at ambient humidity of 60% max.) (with no icing)
Ambient operating humidity 85% max. (for 5°C to 35°C)
Weight Approx. 5.9 g (pin plunger models)
Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
they apply at the total travel position. Contact opening or closing time is within 1 ms.
4. For testing conditions, consult your OMRON sales representative.
141
K K
Approved Standards
Consult your OMRON sales representative for specific models with Contact Specifications
standard approvals.
Contact Specification Rivet
UL1054 (File No. E41515)/
CSA C22.2 No. 55 (File No. LR21642) Material Silver
Rated voltage K Gap 0.5 mm
(standard value)
125 VAC 5A
Inrush current NC 10 A max.
250 VAC 3A
NO 10 A max.
EN61058-1 (File No. 40006539, VDE approval) Minimum applicable load (see note) 160 mA at 5 VDC
Rated voltage K
Note: For more information on the minimum applicable load, refer
125 VAC 5A to Using Micro Loads on page 144.
250 VAC 3A
Contact Form
Testing conditions: 5E4 (50,000 operatings), T80 (0°C to 80°C)
SPDT
50 500 At full OT
Ambient temperature: 20±2°C
K1 Ambient humidity: 65±5% 125 VAC cosφ = 1
30 300 Ambient temperature: 20±2°C
K1
Ambient humidity: 65±5%
20
10 100
7 70
5 50
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminals Mounting Holes
Two, 3.1-dia. mounting holes or
M3 screw holes
3.7
5.1
5.1 4.75±0.1 10.3 ± 0.1
142
K K
143
K K
Hinge Roller Lever Models 4.8 dia. × 4.8 t = 0.5 (see note 2)
Model KjL2
KjL2 (see note 1)
OF max. 0.15 N {{15 g
gf}}
PT A 5.3
34±0.8 +0.13 RF min. 0.015 N {1.5 gf}
3.1 –0.03 dia. holes
PT max. 4.7 mm
2.8 8.1
OT min. 1.3 mm
OP
10.3±0.15 MD max. 2.4 mm
15.9
OP 20.4±2 mm
3.1 +0.13
–0.03
3.4±0.15 dia. Note: 1. Oil-less polyacetal resin roller
10.3
2. Stainless-steel lever
2.8
t=0.5
22.2±0.15 13.4±0.8
Three,
17±0.8 quick-connect
43.3±0.8 terminals (#187)
Precautions
Refer to pages 26 to 31 for common precautions. Use two M3 mounting screws with plain washers or spring washers
to mount the Switch. Tighten the screws to a torque of 0.39 to
Correct Use 0.59 N S m {4 to 6 kgf S cm}.
Mounting Direction Using Micro Loads
For a Switch with an Actuator, mount the Switch in a direction where For details, refer to General Information.
the Actuator weight will not be applied to the Switch.
Since the Switch is designed for a small load, its resetting force is
small. Therefore, resetting failure may occur if unnecessary load is
applied to the Switch.