0% found this document useful (0 votes)
5K views1 page

L & T VFD Parameter List

The document provides details on the configuration parameters for a hoist application using an L&T FX2000 series VFD. It lists 33 parameters to configure including settings for acceleration, deceleration, motor details, I/O functions, and protection. The parameters need to be set based on the specific motor being used and testing done on site.

Uploaded by

mangeshmhokar25
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5K views1 page

L & T VFD Parameter List

The document provides details on the configuration parameters for a hoist application using an L&T FX2000 series VFD. It lists 33 parameters to configure including settings for acceleration, deceleration, motor details, I/O functions, and protection. The parameters need to be set based on the specific motor being used and testing done on site.

Uploaded by

mangeshmhokar25
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DATAR ENGINEERING

FOR HOIST APPLICATION - L & T FX2000 SERIES VFD


SR.NO. PARAMETER PARAMETER NAME & DISCRIPTION SET RANGE SET VALUE

1 CNF-40 Factory setting 1(All Parameter)


Parameter Initialization (Reset) Press'MODE'
Button 3 Times to open CNF Group
2 DRV-3 Acceleration Time 0-6000sec 1sec

3 DRV-4 Deceleration Time 0-6000sec 0.5sec


4 DRV-6 Operating Command Method 0-3 1

5 DRV-7 Frequency setting method 0-8 0


6 DRV-14 Motor Capacity Select Motor Rating KW As per Motor

7 DRV-15 Torque Boost Option 0-3 0


8 DRV-16 Forward Torque Boost 0-15% 4

9 DRV-17 Reverse Torque Boost 0-15% 4


10 BAS-11 Poles As per Motor
Set Value from Motor name plate
Poles=(120XFrequency)/Sync RPM 4

11 BAS-12 Slip As per Motor


Difference between syncronizing
speed motor name plate speed 40

12 BAS-13 Motor Rated Current Set Value from Motor name plate As per Motor

13 BAS-14 NO Load Current Set Value 30-40% Less 40% As per Motor Current
14 BAS-15 Motor Voltage Set Value from Motor name plate 415
15 BAS-16 Motor efficiency Set Value from Motor name plate As Motor(85%)

16 BAS-19 Input power voltage 415 415


17 BAS-20 Auto Tunning 0-6 2 On Site Tunning
18 BAS-50 Fast Frequency 0-Maximum Freq. 50Hz
19 BAS-51 Slow Frequency 0-Maximum Freq. 20Hz

20 OUT-31 Relay-Output-1 (VFD OK Relay) 0-38 22

21 OUT-32 Relay-Output-2 (Brake Relay) 0-38 35

22 OUT-33 Transistor Output (Overload trip) 0-38 41 Deep switch setting


23 IN-67 P3 Input Terminal Function(External Trip) 0-32 4 0
24 ADV-01 Acceleration Pattern Linear 1 1
25 ADV-02 Deceleration Pattern Linear 1 0-Panel testing
Brake Control Parameter 1-site testing
26 ADV-35 Brake Release Fwd Frequency 0-400Hz 0.7Hz

27 ADV-36 Brake Release Rev Frequency 0-400Hz 0.7Hz

28 ADV-38 Brake Open Delay Time 0-10sec 0.2sec

29 ADV-39 Brake Release Fwd Current 0-180% (0-For Panel testing) 20.00%

30 ADV-40 Brake Release Rev Current 0-180% (0-For Panel testing) 20.00%

31 ADV-43 Brake Engage Fwd Frequency 0-400Hz 2 Hz

32 ADV-44 Brake Engage Rev Frequency 0-400Hz 3 Hz

33 ADV-46 Brake Engage Delay Time 0-10sec 0.2sec

Protection Parameter

34 PRT-5 Phase lose Input/Output 1

36 PRT-6 Input Phase Open Voltage Band 1-100V 35V

37 PRT-17 Overload Alarm Selection 0-1 1

38 PRT-18 Overload Alarm Level 30-180% 92% As per site

39 PRT-19 Overload Alarm Time 0-60sec 3sec