A4 - Datasheet Weber Blokfix - Renamed Small
A4 - Datasheet Weber Blokfix - Renamed Small
A4 - Datasheet Weber Blokfix - Renamed Small
With Weber
Block-fix ing is easy
Weber.blokfix is a non-refractory mortar, used for laying masonry • Gradually add 2.5 parts of powder to 1 part of water (by volume)
units like AAC blocks. It is a self-curing mortar made from cement, and mix it for 5-10 minutes to achieve smooth paste consistency.
selected fine sand and polymeric additives, which ensure good
• Attempt to be made to break the lump during mixing so that
bonding and durable strength between the blocks.
maximum dispersion of polymer takes place in the mortar resulting
Key Features into good bonding strength with the blocks.
• Self-curing mortar does not require post curing on blocks fixed • After mixing allow the paste to stand for 2 - 3 minutes to mature and
with weber blokfix. again mix it for paste consistency.
• Ready to mix - water to be added at site as per the mixing ratio. • Do not attempt to extend the pot life by adding more water to the
• Long potlife reduces the wastage at site, at same time large
quantity of material can be mixed. mixed adhesive.
• Good bonding between the blocks and cementitious surface.
• Easy to apply. Application Methodology
• Economical in use.
• Consistent quality material. • Put well mixed weber blokfix on the block with help of trowel,
• Able to withstand hammering, electrical conduting, chiseling and spread mortar uniformly on the unit.
framing done at construction site as per standard masonry
practice. • Apply notch trowel on the mortar and firmly place the block with
• Wall construction speed - Full wall 2-3 days depending upon the slight shear to ensure good transfer & bonding.
adhesive thickness • weber blokfix to be applied on the faces of the block and on column
Recommendation and beam, material to be applied on both i.e surfaces as well as on
block to ensure good bonding at the joints.
It is recommended for fixing AAC, CLC, hollow, concrete blocks &
bricks. • Use rubber hammer to have good contact between the blocks.
• Go on placing the blocks with above method and erect the wall.
TECHNICAL PARAMETERS #
testing parameters @ 27 deg C Pack Size: 40 kg
Appearance Grey powder
Bulk Density 1.45 - 1.55 gm/cc Note
Pot Life 60 minutes • Minimum thickness to be applied is 4mm to take care of the
Open Time 5 - 10 minutes undulation in the blocks as well as to ensure minimum 90% transfer
leading to good bonding strength.
Compressive strength
• Notch trowel to be used for the application of weber blokfix.
@ 28 days > 7.5 Mpa
• Plastering can be done at construction site as per standard
Tensile splitting > 0.3Mpa for 4mm at masonry practice generally after 7 days, conduting and chiseling
strength 28 days valid for 90%
can be done generally after 14 days. Material used for packing on
transfer
the outer block surface is of lower thickness. Rubbing on applied
Initial setting time 350 - 450 minutes thin thickness may cause powdering.
Final setting time 450 - 550 minutes
Consumption
Directions for Use
For 4mm bed thickness coverage is 7 - 7.5 kg/sqm. The coverage will
Surface preparation
vary depending on surface conditions and undulation in blocks.
• Pre wet the blocks and ensure it is touch dry before mortar is
applied. Shelf Life
• The surface for mounting must be thoroughly cleaned of all
12 months from the date of manufacturing in a sealed condition.
laitance, loose materials, oil, grease etc.
• Ensure that surface is flat, structurally sound and free from any Store in a cool dry place.
other contamination which would reduce the bond strength.
• The respective surface should be free from voids, holes and cracks.
Health & Safety: weber blokfix is non-toxic. Use of gloves and goggles is recommended. Any splashes to the skin or eyes should be washed off with clean water. In the event of prolonged irritation,
medical advice should be sought. Weber components are non flammable.
#Note: Pot life, open time and adjustability time varies depending on the service conditions viz temperature, humidity and wind factor.
#Note: These test values were obtained during our laboratory tests. Site mixes may show slight differences in performance due to methods of applications.
Disclaimer: Information on this datasheet is to be treated as guideline for usage. Users are advised to undertake a trial for product suitability prior to it’s full scale usage. There is no express or implied
guaranty/warranty for the results. The company is not liable for any consequential damages.
Marketed by: Saint-Gobain India Pvt. Ltd. – Weber business, Corporate Office: 5th level, Leela Business Park, Andheri-Kurla Road, Andheri East, Mumbai – 400059 India.
Email: [email protected] | Website: www.weber.co.in