Temperature Controller

MICRO-CONTROLLER X
24 × 48 mm
DATA SHEET PXR3-2
PXR3 is an ultra-compact temperature controller which
accepts thermocouple, RTD, or 1–5 V DC as an input. It
provides various control functions such as on/off control, PID
control, 8-step ramp soak, and more.

FEATURES
● PID auto-tuning, self-tuning, and fuzzy control
● NEMA 4X watertight front panel
● Re-transmission output, RS-485 communication (option)
● Alarm (2 points), 8-step ramp soak (option)
● Heating/cooling control version available
● External contact input (2 points), timer function (option)

SPECIFICATIONS
1. General specifications 2. Control functions of standard type
Power supply 100 V (-15%) to 240 V (+10%) AC, 50/60 Control action PID control (with auto tuning, self-tuning)
voltage Hz or Fuzzy control (with auto tuning)
24 V (±10%) AC, 50/60 Hz, 24 V (±10%) Proportional band 0 to 999.9% of measuring range
DC (P) Configurable in 0.1% steps
Power ≤ 6 VA (100 V AC) Integral time (I) 0 to 3200 s
consumption ≤ 8 VA (240 V AC, 24 V AC, 24 V DC) Configurable in 1 s steps
Insulation ≥ 20 MΩ (500 V DC) Differential time 0 to 999.9 s
resistance (D) Configurable in 0.1 s steps
Dielectric Power supply↔Ground: 1500 V AC for 1 On/off action if P = 0. Proportional action when I, D = 0.
strength min Proportional cycle 1 to 150 s
Power supply↔Others: 1500 V AC for 1 min Configurable in 1 s steps
Ground↔Relay output: 1500 V AC for 1 min Only for relay contact output or SSR/SSC
Ground↔Alarm output: 1500 V AC for 1 min drive output
Others: 500 V AC for 1 min Hysteresis width 0 to 50% of measuring range
Input impedance Thermocouple: 1 MΩ or more For on/off action only
Voltage: 450 kΩ or more Anti-reset windup 0 to 100% of measuring range
Current: 250 Ω (external resistor) Automatically adjusted by auto tuning
Allowable signal Thermocouple: 100 Ω or less Input sampling 0.5 s
source resistance Voltage: 1 kΩ or less cycle
Allowable wiring RTD: 10 Ω or less per wire Control cycle 0.5 s
resistance
Reference ±1ºC (at 23ºC) 3. Input section
junction
Input signal Thermocouple : J, K, R, B, S, T, E, N, PLII
compensation
Resistance bulb : Pt100
accuracy
Voltage, current: 1 to 5 V DC, 4 to 20 mA
Input value ±10% of measuring range DC
correction (For the current input, add a provided
Input filter 0 to 900.0 s 250 Ω resistor to the input terminal.)
Configurable in 0.5 s steps (first order lag Measuring range See Table 1.
filter)
Burnout For thermocouple or RTD input, a user can
Noise reduction Normal mode noise (50/60 Hz): 50 dB or select either the upper limit or lower limit as
ratio more the value which the control output should
Common mode noise (50/60 Hz): 140 dB or transmit when a burnout occurs.
more

EDS11-182a
Date Oct. 6, 2017
PXR3-2
4. Output section of standard type (Control output 1) 7. Operation and display section
Control output 1 Select one from the followings: Parameter setting Digital setting by 3 keys
• Relay contact: SPST contact: With key lock function
220 V AC/30 V DC, 3A (resistive load) Display 4-digit, 7-segment LED (red)
Mechanical life: ‌10 million operations (no Process value and set value switchable
load)
Status indicator Control output or alarm output
Electrical life: ‌100,000 operations (rated
load)
(LED)
Minimum switching current: ‌10 mA (5 V Setting accuracy 0.1% or less of measuring range
DC) Indication ‌Thermocouple: ± (0.5% of measuring
• Voltage pulse (for SSR / SSC drive): accuracy (at 23ºC) range) ±1 digit ±1ºC
ON: 15 V DC (12 to 16 V DC) Except:
OFF: 0.5 V DC or less Thermocouple R at 0 to 500ºC: ± (1% of
Max. current: 20 mA or less measuring range) ±1 digit ±1ºC
• 4 to 20 mA DC: Thermocouple B at 0 to 400ºC: ± (5% of
Allowable load resistance: 100 to 500 Ω measuring range) ±1 digit ±1ºC
RTD, voltage, current: ± (0.5% of
5. Control functions of heating/cooling control type measuring range) ±1 digit
(option)
Heating side 0 to 999.9 % of measuring range
8. Alarm (option)
proportional band Alarm kind Absolute alarm, deviation alarm, zone
(P) alarm with upper and lower limits for each
Cooling side Heating side "P" × cooling side coefficient Hold (see below explanation) and latch
proportional band (Automatically set in auto tuning) function available
(P) Cooling side proportional band coefficient: Alarm ON-delay 0 to 9999 s
0 to 100.0 Configurable in 1 s steps
On/off action if P = 0 Process alarm Relay contact: SPST contact: 220 V AC /
Integral time (I) 0 to 3200 s (common to heating and output 30 V DC, 1 A (resistive load)
cooling sides) Mechanical life: ‌10 million operations (no
Differential time 0 to 999.9 s (common to heating and load)
(D) cooling sides) Electrical life: ‌100,000 operations (rated
P, I, D = 0: ‌ON/OFF action (without dead band) for heating and load)
cooling Minimum switching current: ‌10 mA (5 V
I, D = 0: Proportional action DC).
Proportional cycle 1 to 150 s MAX 2 points
For relay contact output or SSR/SSC drive Output cycle: 0.5 s
output only What is alarm with hold?
Hysteresis width 0.5% of measuring range, common to The alarm is not turned ON immediately even when the mesaured value is
heating and cooling sides, for on/off action in the alarm band. It turns ON when it goes out the alarm band and enters
only again.
PV (process value)
Anti-reset windup 0 to 100% of measuring range
Automatically adjusted by auto tuning
Overlap, dead ±50% of heating side proportional band
band Power ON Power OFF Power ON
Area where lower
Input sampling 0.5 s on on limit alarm is output
cycle Lower limit alarm
off off off
on
Control cycle 0.5 s Lower limit alarm off off
(with hold)
6. Output section of heating/cooling control type
(control output 2) (option) 9. Digital input (option)
Control output 2 Select one from the followings: Number of points 1 or 2
• Relay contact: SPST contact: Contact capacity 5 V DC, approx. 2 mA
220 V AC/30 V DC, 3 A (resistive load) ON judgment for 2 V DC or less
Mechanical life: ‌10 million operations (no
OFF judgment for 3 V DC or more
load)
Electrical life: ‌100,000 operations (rated Input pulse width Minimum 0.5 s
load) Available function ‌Set value (front SV, SV1, SV2, or SV3,
Minimum switching current: ‌‌10 mA (5 V (select one) switchable)
DC) Control action start/stop
• Voltage pulse (for SSR/SSC drive): Ramp soak action start/reset
ON: 15 V DC (12 to 16 V DC) Auto tuning start/stop
OFF: 0.5 V DC or less Alarm latch cancel
Max. current: 20 mA or less Built-in timer start
• 4 to 20 mA DC:
Allowable load resistance: 100 to 500 Ω
10. Timer (option)
Startup By digital input
Setting 0 to 9999 s
Configurable in 1 s steps
Default setting is 0 s.
Action Event ON-delay or OFF-delay
Signal output ‌Uses alarm output relay. Up to 2 points
available

2
11. Communication (option) 19. EU Directive Compliance
Physical EIA RS485 LVD (2014/35/EU)
specifications EN 61010-1
Protocol Modbus® RTU mode or PXR protocol EN 61010-2-030
(Z-ASCII) EMC (2014/30/EU)
Communication 2 wires, half duplex bit serial, start-stop EN 61326-1 (Table 2)
method synchronization EN 55011 (Group 1 Class A)
Data type 8 bits. Parity: odd/even/none. EN 61000-3-2 (Class A)
Baud rate 9600 bps EN 61000-3-3
Network topology Multi-drop network RoHS (2011/65/EU)
Up to 32 controllers connectable including EN 50581
master station
Communication Up to 500 m
distance
Recommended ‌Isolated type
RS232C–RS485 K3SC-10 by OMRON Co., Ltd (Japan)
converter http://www.omron.co.jp/
Table 1 Measuring range
12. Re-transmission output (option) Range
Output signal 4–20 mA DC Group Input signal
ºC ºF
Load resistance 500 Ω or less I RTD Pt100 -150 to 850 -238 to 1562
Output updating 500 ms Thermocouple J 0 to 800 32 to 1472
Output accuracy ±0.3% FS (at 23ºC) K 0 to 1200 32 to 2192
Resolution 2000 or more R 0 to 1600 32 to 2912
Kind of output PV, SV, DV, or MV (selectable by
B 0 to 1800 32 to 3272
signal parameter)
S 0 to 1600 32 to 2912
13. Other functions T -150 to 400 -238 to 752
E -150 to 800 -238 to 1472
Parameter mask User can switch show and hide of
parameters N 0 to 1300 32 to 2372
Ramp soak 2 pattern × 4 steps, or 1 pattern × 8 steps PL-II 0 to 1300 32 to 2372
(option) Digital input allows starting or resetting the II 1–5 V DC Scaling range
action. 4–20 mA DC (-1999 to 9999)
Notes:
14. Memory backup at power outage 1. For 4–20 mA DC input, add a 250-ohm resistor provided with
Medium Non-volatile memory the controller.
2. You cannot switch the input type across the groups.
15. Self-diagnosis 3. When the measuring range is beyond 1000ºC, the decimal
Method Program error monitoring by watchdog point is not indicated.
timer

16. Operation and storage conditions


Ambient operating -10ºC to 50ºC
temperature
Scope of Delivery
Ambient operating ≤ 90% RH (no condensation) Controller
humidity Panel mounting adapter
Storage -20ºC to 60ºC Waterproof packing
temperature Instruction manual
250-ohm resistor (when 4–20 mA input is ordered)
17. Structure
Mounting method Panel mount
Rail or wall mount is available by using the
optional DIN rail mounting adapter
External terminal Rod terminal OPTIONAL ITEMS
Case material Plastic (flameproof grade UL94 V-0 Communication manual
equivalent) DIN rail mounting adapter (ZZP CTK368715P1)
Dimensions 24 × 48 × 98 mm
Weight Approx. 150 g
Protective Front panel: NEMA 4X watertight (IEC IP66
structure equivalent) when mounted on panel with
our genuine packing. Waterproof feature is
unavailable in close mounting of multiple
units.
Rear case: IEC IP20
Color Black (front frame, case)

18. Certification
UL, C-UL

3
PXR3-2

CODE SYMBOLS
4 5 6 7 8 9 10111213 14
PXR 3 2 F
Digit Specification Note
4 <Size of front H x W>
24 × 48 mm 3
5 <Input signal>
Thermocouple °C T
Thermocouple °F R
RTD Pt100 Ω 3-wire type °C N
RTD Pt100 Ω 3-wire type °F S
1 to 5 V DC A
4 to 20 mA DC B
6 <Control output 1>
Relay contact output A
SSR/SSC driving output C
4 to 20 mA DC output E
7 <Control output 2>
None Y
Relay contact output Note 1 A
SSR/SSC driving output Note 1 C
4 to 20 mA DC output Note 1 E
8 <Revision code> 2
9 <Optional specifications 1>
None 0
Alarm 1 point 1
8 ramp/soak 4
Alarm 1 point + 8 ramp/soak 5
Alarm 2 point Note 2 F
Alarm 2 point + 8 ramp/soak Note 2 G
10 <Instruction Manual> <Power supply voltage>
None 100 to 240 V AC N
English 100 to 240 V AC V
None 24 V AC/24V DC C
English 24 V AC/24V DC B
11 <Optional specifications 2>
12 None 0 0 0
13 RS-485 Modbus interface M 0 0
RS-485 Z-ASCII interface N 0 0
Re-transmission + Digital input 1 point Note 3 Q 0 0
Re-transmission Note 3 R 0 0
Digital input 2 points T 0 0
RS-485 Modbus interface + Digital input 1 point V 0 0
RS-485 Z-ASCII interface + Digital input 1 point W 0 0
14 <Non-standard specification>
Non-standard parameter setting F
Note 1: Incompatible with two alarms specification (9th code "F" and "G").
Note 2: Incompatible with two control outputs specification (7th code "A", "C", and "E").
Note 3: Incompatible with two control outputs (7th code "A", "C", and "E"), two alarms (9th code "F" and "G"),
and 24 V power supply (10th code "B" and "C").

4
Default Settings
Thermocouple : Type K, range 0–400 ºC, setpoint 0 ºC
RTD : Pt, range 0–150ºC, setpoint 0ºC
Voltage or current : Scaling 0–100%, setpoint 0%

Control action: reverse for control output 1, direct for control output 2.

Change the settings as needed. Front panel keys allow you to switch the input signal setting between thermocouple and RTD,
and to switch the control action between reverse and direct.

Insulation block diagram


Measured value input
Power supply
Internal circuit
Control output 1 (voltage pulse or 4–20 mA)
Control output 1 (relay contact)
Control output 2 (voltage pulse or 4–20 mA)
Re-transmission output
Control output 2 (relay contact)
Digital input (when re-transmission output is used)
Alarm relay output 1 RS-485 communication
Alarm relay output 2 Digital input (re-transmission output unused)
Solid line (―) indicates basic insulation (withstand voltage 1500 V AC)
Dotted line ( ) indicates functional insulation (withstand voltage 500 V AC)

Important notice
The specification of control output differs with models. When you replace temperature controllers, be sure to check if the speci-
fication matches with your application.

SSR/SSC drive output 4–20 mA output


Model
Voltage Max. current allowable load resistance
PXR3 15 V DC 20 mA 100–500 Ω
PXR4 24 V DC 20 mA ≤ 600 Ω
PXV3 5.5 V DC 20 mA ≤ 600 Ω
PXV 24 V DC 60 mA ≤ 600 Ω
PXW 24 V DC 60 mA ≤ 600 Ω
PXZ 24 V DC 60 mA ≤ 600 Ω

5
PXR3-2

OUTLINE DIAGRAM (Unit : mm)


Waltertight packing Mounting bracket
1
48

SV
C1
C2

34.2
24

AL1

22
AL2

SEL

97
4 98

Panel thickness (1 ≤ t ≤ 8)

Panel Cutout (Unit : mm)

For separate mounting For mounting close together (n controllers)


+0.5
+0.5 0
0 a=(48 × n – 3)
45.0
+0.3

+0.3
0

0
22.2

22.2
50 MIN.

57 MIN.
Note: Watertight feature is unavailable if mounted
close together.

6
With DIN Rail Mounting Adapter
52.4

SV
C1
C2
45.4
AL1
AL2
SEL

2- DIN rail
ø4
.3

DIN rail mounting adapter


(option)

For mounting on wall


43.8

M
105.5
109.2

4
36.8
PXR3...
MFD.
No.

Tightening torque 0.49 Nm or less


9

External Connection Diagram


Re-Transmission output
– +
10 11

<Process alarm output 2 or


Control output 2> Digital input 2 Usable wiring material
Relay contact output Wire
4 to 20 mA DC output 14 15 Type: Single Wire
SSR/SSC drive output Digital input 1 Gauge: AWG28 (0.1 mm2) to AWG16 (1.25 mm2)
Communication Strip-off length: 5 to 6 mm
RS-485
– + – +
AWG28 to AWG16
10 11 12 13 14 15 16 17 18

1 2 3 4 5 6 7 8 9 5 to 6mm

A B B Bar terminal
Dimension of strip-off conductor section: 2 × 1.5 mm
RTD input Relay contact output Process alarm Power supply or smaller
output 1 100 to 240V AC Strip-off length: 5 to 6 mm
2 3 2 3 4 5 50/60Hz
250Ω – + – +
8 9 1.5MAX.
Thermocouple 4 to 20 mA DC
input output + –
4 to 20 mA DC 2MAX.
24V DC 5 to 6mm
input 2 3 4 5
Mount resistor to – + – + 24V AC 50/60Hz 8VA
terminals between
2 and 3 1 to 5 V DC SSR/SSC drive output
input
<Control output 1>

7
PXR3-2

Caution on Safety
*Before using this product, be sure to read its instruction manual.

Global Sales Section


Instrumentation & Sensors Planning Dept.
1, Fuji-machi, Hino-city, Tokyo 191-8502, Japan
http://www.fujielectric.com
Phone: +81-42-514-8930 Fax: +81-42-583-8275
http://www.fujielectric.com/products/instruments/

Information in this catalog is subject to change without notice. Printed in Japan

You might also like