Command Codes - Apollo - Rev16, Draft

The document describes global command codes for Apollo. It lists various command codes, their functional codes, descriptions and other attributes. The command codes are used to control functions, retrieve information and configure settings.

Uploaded by

israelpilin123
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views9 pages

Command Codes - Apollo - Rev16, Draft

The document describes global command codes for Apollo. It lists various command codes, their functional codes, descriptions and other attributes. The command codes are used to control functions, retrieve information and configure settings.

Uploaded by

israelpilin123
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

APOLLO

GLOBAL COMMAND CODES


REV 16 - May 6, 2016

Approvers NA EU INDIA
Service Greg Randall Philip Kimberley
Adam Oldham Jürgen Voss,
Engg.
Robert
Regulatory Johnson Gordon Mike M
SQA Shefali Shah Norbert Kranti Kumar, Nishar Ahmed

Date Revision no Description


01-10-2014 1 Apollo Command Codes
15-01-2015 2 Added CC89 ,CC98 to the list
05-02-2015 3 Removed CC87, CC47, CC98, CC93 and changedlimits for CC 53
11-02-2015 4 Added FC 27,28,29 of CC40,CC83 FC 8 , CC22 FC 9 default value changed
20-02-2015 5 Modified the table as per E101 and NA specs
27-02-2015 6 Modified CC83 to 99 descriptions
04-03-2015 7 Added descriptions for CC's as per Global command code spec
20-03-2015 8 Changed CC55 max limit to 7
05-06-2015 9 (Draft Version) Added descriptions for values
10-06-2015 9 Changes as per review comments
03-07-2015 10 Command code 55 removed from the list as same functionality present on CC83FC20
Command code 40 Function code 6 is security switch protected and CC82 FC1 is shifted to
10.1
16-07-2015 CC24 = 6.
24-07-2015 10.2 CC40 FC6 min and max limit revised
CC40FC9 and FC10 modified for MWB, CC91FC29 5 and 6 added,CC76FC11,12,13 added for
11
05-08-2015 LPG/CNG ,CC53.7 security switch not required.
CC89 FC 10,11,12,13,14,15,29,30,31,35,54,61 default value modified, CC84 colour code
12
27-08-2015 changed,CC95 will reset on Hardware coldstart,CC53.12 Description changed.
Security switch not required for CC53 FC1,2,3,4,5,6,7,8,9,10,13,CC53.12 Range and default
13
03-09-2015 value modified, Modified CC32, Added CC 70 as part of Debug Logs.
10-09-2015 13.1 Command code 40 FC 1 range modified.
16-09-2015 13.2 CC40FC10 security switch column updated, CC59.2 security switch column updated
30-09-2015 13.3 Corrected typo error in CC22.3, CC 41 security switch column corrected
Modified CC91.29 (1-Modbus Disabled , 2 - Modbus Enabled),Marking CC40FC26 as Not Used
14
19-10-2015 as the same functionality available in CC40FC25.
Added CC83FC29 (Totals incrementing in calibration)and CC91FC36(HydModule with sat
15
18-03-2015 nozzle)
06-05-2016 16 CC40FC8 default value changed to 2

Command Code Common to both E101 and Sandpiper

Command Code only in E101

Command Code only in Sandpiper

Command Code number changed in both Sandpiper and E101

Command Code Not Used

Command Code number changed in NA

Command Code number changed in E101

Command Code are not accissble by user. These are used internally in software.

Value of the command code may have to be set at power ON

Command code only in Apollo


Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)

0 1 Idle N 0 0 0 N
1.1 Display Electronics platform N 0 1 999999999 N
1
1.2 Display software version N 0 1 999999999 N
1 W&M Hash Code N 0 1 999999999 N
2
2 Display IFSF s/w CRC N 0 1 9999 N
3 - - - - - - -
4 - - - - - - -
5.1 Change Level 0 PIN code. 1st Pass PIN Entry (xxxx is numeric) - - - - -
5.2 2nd Pass PIN Entry (Verification of 1st Pass) - - - - -
5
5.3 Indicates PIN was successfully changed - - - - -
5.0 Indicates PIN was not changed - - - - -
Display Side for which totals are shown N 1 1 4 N
Display grade for which totals are shown N 1 1 6 N
6 1
Display the money Totals N 0 No Range No Range N
- N 0 0 9 N
Display Side for which totals are shown N 1 1 4 N
Display grade for which totals are shown N 1 1 6 N
7 1
Display Volume Totals N 0 No Range No Range N
- N 0 0 9 N
8 - Security Code - - - - -
9 - Command Code - - - - -
Side for which the Blend Ratio information is displayed N 0 0 999999999 N
10 1 Grade for which Blend Ratio information is being displayed N 0 0 999999999 N
Display Blend ratio Percent N 0 0 100 N
11 - View Pressure and Temperature(CNG) 1 1 2 N
(VIEW PRESSURE 11.1.1 Read Current Pressure Side 1 N NA NA NA N
AND 11.1.2 Read Current Temperature Side 1 N NA NA NA N
TEMPERATURE- 11.2.1 Read Current Pressure Side 2 N NA NA NA N
CNG) 11.2.2 Read Current Temperature Side 2 N NA NA NA N
12 Set Side(X) Y 1 1 4 N
(SET DISPENSER 12.X.Y Set Grade(Y) Y 1 1 6 N
OUTPUTS) Set Option/Flow (Set Dispenser Output) Y 0 0 200 N
13 NOT USED N
14.1 Display LPG W&M Data Disable
14 Y 1 1 2 N
14.2 Display LPG W&M Data Enable
0 Display CNG Mass Version N 1 1 3 N
N 0 1 12 N
15.1.X Serial Pulser Number Displayed (X = Pulser number(1-12)) N 0 1 999999 N
N 0 1 9999 N
15 N 0 1 12 N
15.2.X Serial Pulser SW Version Displayed(X = Pulser number(1-12))
N 0 1 999999 N
N 0 1 12 N
15.3.X Serial Pulser SW CRC Displayed (X = Pulser number(1-12)) N 0 1 999999 N
N 0 1 9999 N
(1 - View Pump Serial Number, 2 - View CPU Serial Number, 3 - View Display1 Serial Number,
16
16.X 4- View Display2 Serial Number, 5- View Display3(MultiPPU1)Serial Number, 6 - View
(READ SERIAL N 1 1 8 N
(X = 1 to 6) Display4(MultiPPU2) Serial Number, 7- View Etote Board1 Serial Number, 8 - View Etote
NUMBER)
Board2 Serial Number)
17 NOT USED
18 NOT USED
19 NOT USED
20 Set Side(W) Y 1 1 5 N
Set Grade (Product)(X) Y 1 1 8 N
(SET PRICE PER 20.W.X.Y.Z
Select Level (Fuelling Mode)(Y) Y 1 1 8 N
UNIT VALUES) Set PPU Values(Z)(Max =9999 for 664 display, Max = 99999 for 775 display) Y 0 0 9999/99999 N
21 1 Set Grade Y 1 1 6 Y
Set Custom Density 0 1 9999 Y
22.1.1 No Keypad Preset (Default)
22.1.2 Five Button Preset (Value, Value, Value, Toggle, Clear)
22.1.3 Incremental Preset (Value, Value, Value, Toggle, Clear)
22.1.4 PPP Preset
22.1.5 USA Style Five Button Preset (Value, Value, Value, Toggle, Clear)
22.1.6 USA Style Incremental Preset (Value, Value, Value, Toggle, Clear)
22.1.7 USA Style PPP Preset (Horizon)
22.1.8 Five Button Preset (Value, Value, Value, Value, Clear) Y 1 1 15 N
22.1.9 Incremental Preset (Value, Value, Value, Value, Clear)
22.1.10 USA Style Incremental Preset (Value, Value, Value, Value, Clear)
22.1.11 Incremental Preset (Horizon) (Value, Value, Value, Toggle, Clear)
22.1.12 Configurable Pump Keypad Settings see CC22.10)
22.1.13 Configurable Pump Five Button Preset Settings see CC22.10)
22.1.14 Configurable Pump Incremental Preset Settings see CC22.10)
22.1.15 Configurable Pump PPP Preset Settings see CC22.10)
22.2.1 Set Preset Type (Money or Volume)
22.2.2 Preset Type Volume
Y 1 1 4 N
22 22.2.3 Preset Money only (no Toggle)
(SET PRESET 22.2.4 Preset Volume only (no Toggle)
KEYPAD MODE) 22.3.1 Set Preset Amounts per Key Preset Value Money (ex: 5 Euro)
22.3.2 Preset Value Money (ex: 20 Euro)
Y 1 0 9999 N
22.3.3 Preset Value Money (ex: 10 Euro)
22.3.4 Preset Value Money (ex: 20 Euro)
22.4.1 Set Preset Volumes per Key Preset Value Volume (ex: 1 Liter)
22.4.2 Preset Value Volume (ex: 5 Liter)
Y 1 0 9999 N
22.4.3 Preset Value Volume (ex: 10 Liter)
22.4.4 Preset Value Volume (ex: 20 Liter)
Preset Fill to Nearest Whole Number
22.5 0. Fill to nearest whole number disabled (Default) Y 0 0 5 N
x. Fill to nearest whole number(s) enabled (x = 1...5)
22.6 Preset Fill to Nearest Volume Y 0 0 5 N
22.7 Preset Fill to Nearest Money Y 0 0 5 N
22.8.1 Preset PPP Special Buttons Totals via PPP Preset Keypad disabled
22.8.2 Totals via PPP Preset Keypad enabled Y 1 1 4 N
22.8.4 Stop Button via Preset Keypad enabled
22.9.1 Preset PPP & ENTER key Preset value accepted without ENTER key
Y 2 1 2 N
22.9.2 Preset value accepted with ENTER key only

Page 2
Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)

Configurable Pump Keypad Values 0 No Function


2 Preset value accepted with ENTER key only
x = Key 1…24 Horizon Keypad / SK700 Keypad

0 No Function 20 Push to Stop


1 Preset Value 1 22 Volume Totals
2 Preset Value 2 23 40/70 Button
3 Preset Value 3 29 Backlight On / OFF
4 Preset Value 4 31 Language 1
5 Preset Value 5 32 Language 2
22.10.x Y 1 0 46 N
6 Preset Value 6 33 Language 3
22 7 Preset Value 7 34 Language 4
(SET PRESET 8 Preset Value 8 35 Language 5
KEYPAD MODE) 9 Preset Value 9 41 Bio Methan CNG 1
10 Preset Value 0 42 Bio Methan CNG 2
11 Clear 43 Bio Methan CNG 3
12 Enter 45 Start Button CNG
13 Preset Volume 46 Stop Button CNG
14 Preset Amount
15 Toggle Volume / Amount

Preset Multiplication Factor for Amount


22.11.0
Preset Multiplication Factor disabled Y 0 0 3 N
22.11.x Preset Multiplication Factor enabled (x = 1...3)
22.12 PPP First Digit Entry Point - Volume 0 0 5 N
22.13 PPP First Digit Entry Point - Money 0 0 5 N
23 23.1 LPG Probe Data Y 1 1 7 N
24.1 2-Wire
24.2 Stand Alone
24.3 IFSF 1.51- LON
24.4 IFSF x.xx - LON
24 24.5 ER3
(SET PUMP 24.6 PumaLAN
Y 2 1 12 Y
MODE OF 24.7 ATCL
OPERATION) 24.8 Multi Wire Interface
24.9 Australia Two-Wire Protocol 1
24.10 Australia Two-Wire Protocol 2
24.11 Nuovo Pignone
24.12 Wayne Current Loop
25.1 Max Allocation Volume Grade 1
25 25.2 Max Allocation Volume Grade 2
(SET 25.3 Max Allocation Volume Grade 3
Y 0 N
ALLOCATION 25.4 Max Allocation Volume Grade 4 0 999999
VOLUME) 25.5 Max Allocation Volume Grade 5
25.6 Max Allocation Volume Grade 6
26 NOT USED
27.1.x Audit Last Transaction
27.2.x Display Volume Correction Factor
27.3.x Display Fuel Density
27 27.4.x Display Temperature
N 1 1 8 N
(REVIEW ATC) 27.5.x Gross Volume Totals
27.6.x Software version
27.7.x Real Time Transaction
27.8.x Engineering Audit
28 28.1 1st Pass PIN Entry (xxxx is numeric)
28.2 2nd Pass PIN Entry (Verification of 1st Pass)
(CHANGE FIRST Y - 0 9999 N
28.3 Indicates PIN was successfully changed
LEVEL PIN) 28.0 Indicates PIN was not changed
29 NOT USED
30 NOT USED
31.1 Max Amount Limits Grade1 Y
31 31.2 Max Amount Limits Grade2 Y
31.3 Max Amount Limits Grade3 Y
(SET AMOUNT 0 0 999999 N
31.4 Max Amount Limits Grade4 Y
LIMITS) 31.5 Max Amount Limits Grade5 Y
31.6 Max Amount Limits Grade6 Y
32 32.1 Display Last fuelling of side 1
(SHOW LAST N Display Last Transaction Value N
32.2 Display Last fuelling of side 2
FUELLING)
33
(SHOW AUTO 33.1 Set Side 1 1 4 N
Y
REGULATION
33.2 Display Regulation Factor for that Side 0 0 999 N
FACTOR)
34 NOT USED
35 NOT USED
36 NOT USED
37 NOT USED
38 NOT USED
39 NOT USED

Set 2-Wire, ATCL, Nuovo Pignone, Puma LAN Protocol Address – Function Code 1 Protocol
40.1.1
Address Side 1 Y 0 1 16 N

40.1.2 Protocol Address Side 2


Note: Addresses Range: 2-Wire: 1...16 / ATCL: 1...8 / Puma LAN: 1…16 / Nuovo Pignone: 1...8 WCL: 1...16
Set 2-Wire, ATCL, Nuovo Pignone, Puma LAN Baud Rate – Function Code 2 for 2-Wire,
40.2.1 ER3 Default -
Baud Rate 5787 bps 2-Wire, WCL
40 40.2.2 Baud Rate 4800 bps 2-Wire, ATCL, Puma LAN >1
(SET 40.2.3 Baud Rate 1200 bps ATCL for ATCL,
40.2.4 Baud Rate 9600 bps 2-Wire, ATCL Y 1 6 N
COMMUNICATIO Australia Two-
40.2.5 Baud Rate 19200 bps 2-Wire Wire, Puma
N PARAMETERS)
40.2.6 Baud Rate 2400 bps Nuovo Pignone LAN Default ->
2
40.3 Set IFSF - LON Node Address – Function Code 3 Set IFSF Node Id Y 27 1 127 N
40.4.1 Set Communication Lost – Function Code 4 - Set suspend
Y 1 1 2 N
40.4.2 No suspend

Page 3
Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)
40.5.1 Set Real time Volume
40.5.2 Real time Volume Y 1 1 3 N
40.5.3 Real time Money & Volume
Set Volume Pulse Scale (Multi Wire Interface) – Function Code 6
40.6.100 only three values 10, 50 &
100 Pulses / Liter Y 100 Y
40.6.50 50 Pulses / Liter 100 acceptable
40.6.10 10 Pulses / Liter
Set Amount Pulses (Multi Wire Interface) – Function Code 7
40.7.1
Amount Pulses enabled Y 1 1 2 N
40.7.2 Amount Pulses disabled
Set Auto Authorization (Multi Wire Interface) – Function Code 8
40.8.1
Auto Authorization enabled Y 2 1 2 N
40.8.2 Auto Authorization disabled
Set start position of Pulse Channels (Multi Wire Interface) – Function Code 9
40.9.1
Both Pulse Channels start with “low” Y 1 1 2 N
40.9.2 Both Pulse Channels start with “high”
Set Pulse Format (Multi Wire Interface) – Function Code 10
40.10.1
1 - Parallel Pulses

40.10.2 2-Complementry Pulses


Y 1 1 4 Y
40.10.3 3-Non - Overlapping Pulses

40.10.4 4- Quadrature Pulses

Set additional pulses via Multi Wire-Interface – Function Code 11


40.11.1
Pulses via Multi Wire Interface and CC24 ≠ 8 disabled
40.11.10 10 Pulses / kg via Multi Wire Interface and CC24 ≠ 8 enabled Y 1 1 100 N
40.11.50 50 Pulses / kg via Multi Wire Interface and CC24 ≠ 8 enabled
40.11.100 100 Pulses / kg via Multi Wire Interface and CC24 ≠ 8 enabled
Set Australia Two-Wire EOT Timer – Function Code 12
40.12.5 Y 3 1 10 N
Number of Seconds EOT is reported (1…10 sec.)
Set Keypad Preset with Remote Preset (Australia or Standard Two-Wire) – Function Code
40.13.1
13 Keypad Preset Allowed with Remote Preset Y 1 1 2 N
40 40.13.2 Keypad Preset NOT Allowed with Remote Preset
(SET Set Special EOT with 2-wire (CC24= 1) and Preset – Function Code 14
40.14.1
COMMUNICATIO EOT corporate 2-wire Y 1 1 3 N
N PARAMETERS) 40.14.2 EOT with nozzle out (2-wire (CC24= 1) and Preset only)
40.14.3 EOT with nozzle out (ER3 (CC24= 5) and 87.2 Maximum Fill Timeout reached)
40.15 lights On/ Off on command for Aus Y 2 1 2 N
40.16 Special Two-Wire Timings Y 1 1 2 N
Set Special parameter for SNIP & Fusion Master POS (Nuovo Pignone) – Function Code 17
40.17.1
POS : SINP system Y 2 1 2 N
40.17.2 POS : Fusion Master
40.18.1 Set IFSF Serial Mode (TCP/IP) – Function Code 18 IFSF LON Mode
Y 1 1 2 N
40.18.2 IFSF TCP/IP Mode
40.19.1 Set DHCP on/ioff – Function Code 19
Y 2 1 2 N
40.19.2 DHCP disabled
Set IP Address – Function Code 20 / aaa.bbb.ccc.ddd will be stored after the latest input 1 1 4
40.20.1
aaa 0 0 255
40.20.2 bbb Y 0 0 255 N
40.20.3 ccc 0 0 255
40.20.4 ddd 0 0 255
Set Subnet-Mask – Function Code 21 / aaa.bbb.ccc.ddd will be stored after the latest input 1 1 4
40.21.1
aaa 255 0 255
40.21.2 bbb Y 255 0 255 N
40.21.3 ccc 255 0 255
40.21.4 ddd 0 0 255
40.22 Set Timeout in Seconds for Tw communication Y 10 0 240 N
40.23 Digit Selection (1-5digit,2-6digit,3-7digit,4-8digit) Y 1 1 4 N
Set Reported Volume Decimal Point Location ( 1 - Same Decimal as on Volume Display, 2 - 3
40.24 Y 2 1 3 N
Deciaml Figures : XXX.XXX)
TW Error State in Transaction Data(1 - no Error in Trxn data , 2 - EVR Error in Trxn data , 3 -
40.25 Y 1 1 3 N
Two wire Error in Trxn data)
40.26 NOT USED
40.27 Set Status Response Format ( 1- Standard Response , 2 - Alternate Response ) Y 1 1 2 N
Preset Mode Without Pump Stop ( 1- Allow One Preset , 2 - Allow any Preset Until Fuelling
40.28 Y 1 1 2 N
Starts)
40.29 2W Grade Remapping Y 1 1 2 N
Set PPU Display Option
Level Code L1 Displays L2 Displays
1 From POS NA
2 Price Level 1 Price Level 2
41 41.1 Y 1 1 6 N
3 Price Level 2 Price Level 1
4 NA From POS
5 Price Level 1 NA
6 NA Price Level 1
42 NOT USED
Set PPU Blinking Option ( 1 - PPU Flash with Grade Light , 2- PPU Grade Light with No
43 43.1 Y 1 1 4 N
Flashing , 3 -Grade Light Flashing Only , 4 - PPU Backlight as Grade Indicator)
44 NOT USED
45 45.1 Set Lamp Test Time Y 3 2 9 N
46 NOT USED
47 NOT USED
48 NOT USED
0 Function Code Y 1 1 4 N
49 49.1 Set STP Prestart Delay(0 - STP off ; 2….12 sec) Y 0 0 12 N
49.2 Set Control Type Option Y 1 1 2 N
(STP CONTROLS)
49.3 STP Mapping Option Y 1 1 2 N
49.4 Set LPG-STP Control Mode(1 - LPG_STP_STANDARD; 2 - LPG_STP_ON_POB) Y 1 1 2 N
50 NOT USED
51
51.1 Set Beeper Option (1 - ON ; 2 - OFF) Y 1 1 2 Y
(SET BEEPER)

Page 4
Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)
52
(SET STOP
52.1 Set Vapor Vac Alarm ( 1- ON , 2 - OFF) Y 2 1 2 Y
BUTTON
CONTROL)
0 Function Code Y 1 1 13 Y
53.1 Set Beeper Timeout(0…255 sec) Y 0 0 255 N
53.2 Set Preset Timeout(0…999 sec) Y 30 0 999 N
53.3 Set Initial Beeper Timeout(0…255 sec) Y 0 0 255 N
53.4 Set Guard Timeout(0…255 sec) Y 5 0 255 N
53 53.5 Set Maximum Authorise time(0…255 sec) Y 0 0 255 N
(SET TIMEOUTS) 53.6.x.yyy x = Set Side(1 -4) Y 1 1 4 N
53.6.x.yyy yyy = Set Nozzle Changing Time between UHF Nozzle and Sat Nozzle Per Side (0…120 sec) Y 0 0 120 N
Set Display Backlight Power Safe Mode(0…180 sec where 0 - no satellite timeout and 15 -
53.7 Y 0 0 180 N
180 - user settable range)
53.8 Set Dead Man Button Timeout(1…30 sec) Y 5 1 30 N
9 Set Vapor Crush Time Y 2 1 9 N
10 Set Total Vapor Time Y 30 1 99 N
53(SET TIMEOUTS) 11 Enter Max Time without Progress(Dispensing) (In Seconds) Y 90 0 250 Y
12 Maximum Fill (Dispense )timeout (1 unit = 10 sec) Y 18 0 180 Y
13 Initial Dispenser Timeout ( In Seconds) Y 0 0 250 N
54 NOT USED
55 NOT USED
56
(SET STOP
56.1 To Set Stop Button Control(1 - Stop 1 side only ; 2 - Stop both sides) Y 2 1 2 N
BUTTON
CONTROL)
57 xx Volume display show xx = Number of Error
ENTER Jump to the Errors (the last in is shown at first)
57 X YY Volume display show X = Side / YY = Error code
(READOUT THE Z Volume display show Z = Source of the Erro
ERROR MEMORY xx PPU show: xx = Number of the event N 0 1 999999 N
WITH THE Key 1 Toggle between Time / Date and Error
HHMM Amount display show: Time information of the Error
KEYPAD) MMTTJJ Volume display show: Date information of the Error
xx PPU show: xx = Number of the event
58.2.1.1 No Valve set for Grade1 on Side 1 Y N
58.2.1.2 Valve 1 for Side 1 Set for Grade 2 Y N
58
58.2.1.3 Valve2 for Side 1 Set for Grade 3 Y N
(SPECIAL VALVE 0 0 6
58.2.1.4 No Valve Set for Grade 4 on Side 1 Y N
MAPS)
58.2.1.5 Valve 5 for Side 1 Set for Grade 5 Y N
58.2.1.6 Valve 6 for Side 1 set for Grade 6 Y N
59.1
To select type of Dispenser Cold Start: 1-ColdStart
59 N Y
(DISPENSER 1 1 3
COLDSTART) 59.2 2-Reset Log - File N N
59.3 Reboot N N
0 Function Code Y 1 1 3 Y
60
60.1.hhmm Set Time for the RTC (HHMM ; here 99:99) Y 1 1 9999 Y
(SET CLOCK AND
60.2.mmddyy Set Date (MMDDYY) Y 1 1 999999 Y
CALENDAR)
60.3 Set DayLight Savings Time ( 1 - Disabled , 2 - USA , 3 - Canada , 4 - Mexico ) Y 1 1 4 Y
61
1 Leading Zero ( 1 - Without Leading Zero , 2 - With Leading Zero ) Y 1 1 2 N
(LEADING ZERO)
62 NOT USED
Set Alternate Fuel ( 1-Standard Fuel , 2- 3rd Party Fuels , 3 - DEF , 4 - Diesel + DEF , 5 - 3rd
63
Party CNG/LNG with GGE to Pounds ,
(SET ALTERNATE 1 Y 1 1 9 Y
6 - 3rd Party CNG/LNG with GGE to Kilograms , 7 - 3rd Party CNG/LNG with GLE to Pounds ,
FUEL)
8 - 3rd Party CNG/LNG with GLE to Pounds, 3rd Party LPG with Proportional Valve)
65 1 Maximum Nozzle Changes On Authorise Time Y 1 1 2 N
66 NOT USED
67 NOT USED
68 NOT USED
69 0 Function code Y 1 1 3 Y
1 Set Fuel Leak Test ( 1 - Disable , 2- Enable ) Y 1 1 2 Y
(SET FUEL LEAK
2 Set Leak Test Time in milliseconds Y 2000 0 99999 Y
TEST) 3 Set Leak Test Volume in millilitre Y 200 0 9999 Y
70 1 Debug Logs( 0 - Disable Debug Logs , 1 - Enable Debug Logs) Y 0 0 1 N
71
Set Volume Unit ( 0 - Default , 1 - US Gallons , 2 - Litres , 3 - Imperial Gallons , 4-
(SET VOLUME 1 Y 2 0 3 Y
Reserved(Currently Unused) , 5-Hawaii Gallons)
UNITS)
72 Select Nozzle for which Blending Ratio is to be set Y 1 1 6 Y
(SET BLEND 1
RATIOS) Set Blending Percent Y 0 0 120 Y

Select Side Y 1 1 4 Y
73
(SET/DISPLAY 1 Select Grade Y 1 1 6 Y
MONEY TOTALS)
Set/Display Money totals Y 1 - - Y
74 Select Side Y 1 1 4 Y
(SET/DISPLAY
1 Select Grade Y 1 1 6 Y
VOLUME
TOTALS) Set/Display Volume Totals Y 1 - - Y
75 75.X.Y Set Fuel Density for Side X Y 0 1 6 Y
(SET FUEL Please refer
DENSITY) Set Density Value Y Y 0 0 19 Y
Appendix
0 Function code Y 1 1 10 Y
76.1 Calibration Fuelling (if ECAL switch is opened) or Test fuelling (if ECAL switch is closed) Y 0 1000 210000 Y
Direct Input of the Calibration Factor where X is SIP NO Y 1 1 12 Y
76.2.X.Y
Direct Input of the Calibration Factor where Y is the Calibration Value Y 0 10000 700000 Y
3 Show Current Meter Number Y 1 1 12 Y
3 Shoe Switch Status Y 0 0 1 Y

Page 5
Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)
3 Show Current Meter UHF Y 1 1 12 Y
3 Show Switch UHF Y 0 0 1 Y
Read Serial Intelligent Pulser (SIP) Serial Number Where X is the Number of SIP Y 1 1 12 Y
76.6.X Read first line for SIP Manf Date Y 0 0 999999 Y
Read Second line for SIP product no Y 0 0 999999 Y
76 Read first line for SIP Manf Date Y 0 0 999999 Y
(NEW Read Second line for SIP product no Y 0 0 999999 Y
CALIBRATION 76.7.X
After Reading press Enter & Set Address for Serial Intelligent Pulser which has its calibration
PROCEDURE) Y 0 0 12 Y
switch open.
8 Y 1 1 12 Y
Set Zero Point of the Coriolis Meter
8 Y 0 0 999999 Y
9 Set Address for Coriolis Meter (Modbus) Y 1 1 12 Y
10 Y 1 1 12 Y
Show EM Totals Display / Port Number to Selected Nozzle
10 Y 0 0 1 Y
Enter Meter Number Y 1 1 12 N
11
Set Low Flow Cut Off Value Y 0 0 999999 N
Enter Meter Number Y 1 1 12 N
12
Show K- Factor Value ( There will be no default, will readout value from meter) N - 0 999999 N
Enter Meter Number Y 1 1 12 N
13
Show Zero Point Value ( There will be no default, will readout value from meter) N - 0 999999 N
Change Level PIN Codes–Pass result 0 0 3 N
77 1 Enter Function Code Y 0 0 5 N
Enter New Pin Code 0 0 9999 N
78
(SELECT CAN 1 Select Can Size Y 0 1 999 Y
SIZE)
79
(AUTOMATED
VAPOR 0 Automated Vapor Recovery Testing ( 1 -Perform Test , 2 - View Previous Test Result) Y 1 1 2 N
RECOVERY
TESTING)
80 Set Side Y 1 1 4 Y
(SET MAXIMUM
1 Set Grade Y 1 1 6 Y
FLOW RATE PER
GRADE) Set Flow Rate ( If Flow rate is set to 0 it will take default value as 40) Y 40 0 200 Y
81 1 Allow Blend Ratio changes in level 2 Y 0 0 1 N
0 Function code Y 1 1 21 N
82.1 NOT USED
82.2 Set Product Associated Nozzle 1 Side A Y 0 0 9 N
82.3 Set Product Associated Nozzle 2 Side A Y 0 0 9 N
82.4 Set Product Associated Nozzle 3 Side A Y 0 0 9 N
82.5 Set Product Associated Nozzle 4 Side A Y 0 0 9 N
82.6 Set Product Associated Nozzle 1 Side B Y 0 0 9 N
82.7 Set Product Associated Nozzle 2 Side B Y 0 0 9 N
82.8 Set Product Associated Nozzle 3 Side B Y 0 0 9 N
82.9 Set Product Associated Nozzle 4 Side B Y 0 0 9 N
82
82.10 Set Multiplicative Factor of Credit received on Automatic Function Y 1 0 3 Y
(LAN OPTIONS) 82.11 Set LAN Number side A Y 0 1 32 N
82.12 Set LAN Number side B Y 0 1 32 N
82.13 Set Prepay delivery duration Y 0 1 250 Y
82.14 Set not Prepay Delivery Duration expressed in Sec Y 0 0 250 Y
82.15 Set Min. Delivered Millimeters number to Preserve Credit Y 250 1 250 Y
82.16 Set Min. showed Millilitres number Y 29 1 250 Y
82.17 Set Min.delivered Millilitres number to change the Nz Y 100 1 250 Y
82.18 Set Max.Number of times the same Nz can be pulled out Y 3 1 9 Y
82.19 Set Sec of Min level of Debouncing Y 9 2 99 Y
82.20 Set Manual Price Type Y 0 3 1 N
82.21 Set Autman Polarity Y 0 0 1 Y
0 Function Code Y 1 1 21 N
82.1 Set Wcl active Y 0 0 1 N
82.2 Set Product Associated Nozzle 1 Side A Y 1 0 4 N
82.3 Set Product Associated Nozzle 2 Side A Y 2 0 4 N
82.4 Set Product Associated Nozzle 3 Side A Y 3 0 4 N
82.5 Set Product Associated Nozzle 4 Side A Y 4 0 4 N
82.6 Set Product Associated Nozzle 1 Side B Y 1 0 4 N
82.7 Set Product Associated Nozzle 2 Side B Y 2 0 4 N
82.8 Set Product Associated Nozzle 3 Side B Y 3 0 4 N
82 82.9 Set Product Associated Nozzle 4 Side B Y 4 0 4 N
82.10 Set Multiplicative Factor of Credit received on Automatic function Y 3 0 3 Y
(WCL
82.11 Set LAN Number side A Y 1 1 32 N
CONVERTER) 82.12 Set LAN Number side B Y 2 1 32 N
82.13 Set Prepay delivery duration Y 36 1 250 Y
82.14 Set not prepay Delivery Duration expressed in Sec Y 0 0 250 Y
82.15 Set Min. Delivered Millimeters number to Preserve Credit Y 29 1 250 Y
82.16 Set Min. showed Millilitres number Y 29 1 250 Y
82.17 Set Min.Delivered Millilitres number to change the Nz Y 29 1 250 Y
82.18 Set Max.number of times the same Nz can be pulled out Y 3 2 9 Y
82.19 Set Sec of Min level of Debouncing Y 9 3 99 Y
82.20 Set Manual Price Type Y 0 0 1 N
82.21 Set Autman Polarity Y 0 0 1 Y
0 Function code Y 1 1 25 Y
Set Vapour Recovery Hose Leak Test (1-Without Leak Test, 2 - with Italy Leak Test, 3 - With
83.1 Y 1 1 3 Y
France Leak Test)
set IFSF - LON Wire Restriction (1-IFSF - LON write restriction disabled, 2-IFSF-LON write
83.2 Y 2 1 9 Y
restriction enabled)
Set rounding algorithm for Amount (1 Rounding Algorithm for Amount disabled, 2 Special
83.3 Preset rounding for Poland, 3 Special Preset rounding for Nordic, 4 Special Preset rounding Y 1 1 4 Y
for Russia)
Set Initial Value Suppresion Algorithm (Initial Value Suppression Algorithm disabled, 2 Initial
83.4 Y 1 1 3 Y
Value Suppression Algorithm enabled)
83.5 Nozzle Back During Lamp Test (2 - Zero transaction data) Y 1 1 2 Y
Clear Display With Release Command In 2 W (1 Clear Display option disabled, 2 Clear
83.6 Y 1 0 2 Y
Display option enabled / Clear Display option after release (Huth))
NOT USED

Page 6
Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)
2 Wire Price Change (1 Price change immediately, 2 Price change after pull nozzle, 3 Price
83.8 Y 1 1 5 Y
change immediately with clear display)
NOT USED
83 Set ZModem Hardware Flow Control (1 Hardware Flow Control disabled, 2 Hardware Flow
(SPECIAL 83.10 Y 2 1 2 N
Control enabled)
OPTIONS) Set Special Nozzle Release (1 Special Nozzle Release disabled, 2 Fiscal Nozzle Release
83.11 Y 1 0 3 Y
enabled, 3 IVPGL Nozzle Release enabled)
83.12 Custom Minimum Volume to Display Y 29 0 250 Y
Preset Display Indicator ( 1- Preset Indicator Disabled , 2 - Preset Indicator English , 3 - Preset
83.13 Indicator Spanish1 , 4 - Preset Indicator Spanish2, 5 - Preset Indicator Zero,6 - Preset Y 1 1 6 Y
Indicator Dash)
Set Indicator LED on Combi Display (1 Disabled, 2 Enabled (LED show state of VRM), 3
83.14 Y 1 1 4 N
Enabled (LED show state of VR Italy))
83.15 Set Single PPU works in Multi PPU (1 Disabled, 2 enabled) Y 1 1 2 N
83.16 Logging Transaction Data Y 1 1 2 N
83.17 Pump Automated Option Per Country Y 0 0 4 Y
83.18 Kuwait Rounding - off - Enable/Disable option Y 1 1 2 Y
83.19 Set Remote Preset Display option (1 Desabled, 2 Enabled) Y 1 1 2 Y
USA style Hose pressurisation ( 1- USA Hose Pressurisation Disable,2 -Hose Pressurisation
83.20 Time 10 min, 3 - Hose Pressurisation Time 30 min, 4 - Hose Pressurisation Time 1 hour, 5 - Y 1 1 5 Y
Hose Pressurisation Time 4 hours)
83.21 Set LPG min Flow Rate Y 0 1 10 Y
83.22 Set Audio options (1 Disabled, 2 CEPSA Synthesizer, 3 GVR Grade Announcer II) Y 1 1 2 N
83
83.23 Set Vibration Sensor Enabled Y 1 1 3 Y
(SPECIAL OPTIONS) 83.24 Set Australia LPG Vapour Detection Y 1 1 3 N
83.25 Pulsing while Inhibited (PWI) Y 0 0 10
83.29 Incrementing totals while in Calibration(1-Disabled, 2-Enabled) Y 1 1 2 Y
84
(SET W&M TEST 84.X Set W&M Test Mode option (X = 1 W&M test desabled, 2 W&M test enabled) Y 1 1 2 Y
MODE)
Function Code 1 1 4 Y
85 85.1.X Set Money Decimal point for Display (X = 1 - 0 dgts after decimal point, 2 - 1 dgts after dec, 3- Y 3 1 4 Y
(SET DECIMAL 85.2.X Set Volume Decimal Point for Display (X = same as above) Y 3 3 4 Y
POINTS) 85.3.X Set PPU Decimal Point for Calculation (X = same as above) Y 4 1 4 Y
85.4.X Set PPU Decimal position for Display (X = same as above) Y 4 1 4 Y
86
(SET
- Set Symbol ( Comma/Decimal) (1-Decimal point, 2-Comma) Y 2 1 2 Y
COMMA/DECIM
AL POINT)
87 NOT USED
88 Select Side X (SlowDown Valve) Y 1 1 4 Y
(SET 88.X.Y Select Grade Y Y 1 1 6 Y
SLOWDOWN Drosselwert in cl Y 50 30 70 Y
0 function code Y 1 1 67 Y
89.1 CNG Active (Disable-1 and Enable -2) Y 1 1 2 Y
89.2 LeakTestTimeCar sec Y 5 1 99 Y
89.3 LeakTestTimeBus sec Y 5 1 99 Y
89.4 Max Tank Pressure limit to refill car Y 195 1 270 Y
89.5 Max Tank Pressure limit to refill Bus Y 195 1 270 Y
89.6 Mid Tank Pressure Limit to refill Car Y 150 1 200 Y
89.7 Mid Tank Pressure Limit to refill Bus Y 150 1 200 Y
89.8 Low Tank Pressure Limit to Refill Car Y 100 1 200 Y
89.9 Low Tank Pressure Limit to Refill Bus Y 100 1 200 Y
89.10 Fill Quantity Low Tank Pressure Car Y 20 1 100 Y
89.11 Fill Quantity Low Tank Pressure Bus Y 60 1 100 Y
89.12 Fill Quantity Mid Tank Pressure Car Y 10 1 100 Y
89.13 Fill Quantity Mid Tank Pressure Bus Y 40 1 100 Y
89.14 Fill Quantity High Tank Pressure Car Y 5 1 100 Y
89.15 Fill Quantity High Tank Pressure Bus Y 20 1 100 Y
89.16 Flow Rate to Switchover to Mid Bank Car Y 36 1 300 Y
89.17 Flow Rate to Switchover to Mid Bank Bus Y 60 1 300 Y
89.18 Flow Rate to Switchover to High Bank Car Y 24 1 300 Y
89.19 Flow Rate to Switchover to High Bank Bus Y 48 1 300 Y
89.20 Min Flow Rate to Stop Filling on High Bank Car Y 12 0 100 Y
89.21 Min Flow Rate to Stop Filling on High Bank Bus Y 24 0 100 Y
89.22 Correction Factor for the Calculation of Max Mass Car Y 85 1 130 Y
89.23 Correction Factor for the Calculation of Max Mass Bus Y 85 1 130 Y
89.24 FilledMassAfterFirstFillingStrokeCar in gramm Y 300 1 5000 Y
89.25 FilledMassAfterFirstFillingStrokeBus in gramm Y 300 1 5000 Y
89.26 Max FlowRateCar Y 60 1 100 Y
89.27 Max FlowRateBus Y 80 1 150 Y
Failure Signal Contact ( 0 - Failure Signal Contact -> Closes by Fault , 1 - Failure Signal
89.28 Y 0 0 1 Y
Contact -> Opens by Fault)
89.29 Temperature Compensated Fill Pressure( 1 - 200 bar at 15 degree , 2 - 250 bar at 21 degree) Y 1 1 2 Y
89.30 Leak Test Pressure Loss Car Y 10 1 99 Y
89.31 Leak Test Pressure Loss Bus Y 10 1 99 Y
89.32 Max pressure to stop filling Y 250 1 295 Y
89 89.33 Natural Gas Density Y 75 55 200 Y
(SET CNG Select Bank Valve for Filling Stroke ( 0 - No Valve , 1 - LB Valve (Low Bank) , 2 - MB Valve (Mid
89.34 Y 2 0 3 Y
PARAMETER) Bank) , 3 - HB Valve (High bank))
89.35 Enhanced Diagnostic Information Output (0 - Disabled , 1 - Enabled) Y 0 0 255 Y
89.36 Dynamic Pressure Range Y 5 1 9 Y
89.37 Button type( 1-StartStop,2-DeadMan,3-ZV-Keypad,4-ProdSelect,5-NA GradeSelect) Y 1 1 6 Y
89.38 Hydraulic assignement for CNG Pump (1-Standard, 2-Y, 3-NozSel, 4-BioMethan) Y 1 1 4 Y
89.39 Transition Level between mass and Pressure filling procedure Car Y 0 0 80 Y
89.40 Transition Level between mass and Pressure filling procedure Bus Y 0 0 80 Y
89.41 OffsetToActivateTankPressureCalc Car Y 50 1 99 Y
89.42 OffsetToActivateTankPressureCalc Bus Y 50 1 99 Y
Set Displayed Unit Type( 1 - Kg , 2- Norm Cubic Meter , 3 - Gasoline Gallon Equivalent , 4 -
89.43 Y 1 1 4 Y
Gasoline Litre Equivalent)
89.44 Start Compressor Signal ( 1 - Disabled , 2 - Enabled) Y 1 1 2 Y
89.45 CNG Pump Type (0- Standard, 1 NA, 2-Russia) Y 1 0 2 Y
89.46 Pressure Monitoring in PPU: (1-Disabled, 2-Bar, 3-PSI) Y 1 1 3 Y
89.47 LeakTestMode (0-Disabled,1-Switzerland,2-Austria,3-LedControl) Y 0 0 3 Y
Pressure Measuring Y -Type( 1 - Hose Valve Open During Pressure Measuring , 2 - Hose
89.48 Y 1 1 2 Y
Valve Closed Before Pressure Measuring)

Page 7
Protected by
the
Command Functional Configurable(Y Default Lower Higher
Functional detail security
Code Code /N) Value Limit Limit
(calibration)
switch (Y/N)
89.49 Overpressure Safety switch with Gauge( 1 - Disable , 2 - Enable) Y 2 1 2 Y
89.50 Knock Over Protection (1: Disable & 2: Enable) Y 2 1 2 Y
89.51 Norm Cubic meter conv.factor Y 1000 1000 1500 Y
89.52 Pressure Control Filling (Disable :1 & Enable:2) Y 1 1 2 Y
89.53 Set the Pressure Transducer Type ( 1 -BAR , 2 - PSI ) Y 1 1 2 Y
89.54 Level for Refill in Percent Y 95 0 100 Y
89.55 TargetPressureCorrection Car ( In Bar) Y 10 0 99 Y
89.56 Target Pressure Correction Bus ( In Bar) Y 20 0 99 Y
89.57 CNG EU Nozzel Type Car ( 1 - Disable , 2 - Enable) Y 1 1 3 Y
89.58 CNG EU Nozzel Type Bus( 1 - Disable , 2 - Enable ) Y 1 1 3 Y
89.59 CNG Beeper timeout( 0 - Disable , 1…255 - Set EOT Beeper Timeout) Y 10 0 255 Y
89.60 CNG PressureCounter ( 0 - Disable , 2…20 - Enable Pressure Counter) Y 4 2 20 Y
89.61 CNG RetrofitVehicleFill (1-Disable, 2-Enable) Y 1 1 9 Y
89.62 CNG 2 Hose Single Grade NA (1-Disable, 2-Enable) Y 1 1 2 Y
89.63 CNG 2 Hose Unit Nozzle Assignment Side1 Y 1 1 2 Y
89.64 CNG 2 Hose Unit Nozzle Assignment Side2 Y 1 1 2 Y
89.65 FlowRate To SwitchTo All Banks Car Y 12 1 300 Y
89.66 FlowRateTo SwitchTo All Banks Bus Y 24 1 300 Y
89.67 CNG LpgTestRefPressureCounter Austria Y 7 1 20 Y
90 1 Set Unit Type (Refer Appendix Below*) Y 1 - - Y
0 Enter Function Code Y 1 1 44 Y
91.1 To Set Preset Keypad Type Y 1 1 4 Y
91.2 To Set Push to Start Option(1 - Disable , 2 - Enable) Y 1 1 2 Y
91.3 To select Vapor Vac Option Y 1 1 4 Y
Set Display Per Side (1- Per Side - 1 Display , 2 - Per Side-2 Displays , 3 - Side 1 - 2 Displays ,
91.4 Y 1 1 4 Y
Side2-1Display, 4- Side 1 - 1Display, Side 2 - 2Displays)
91.5 To Set Push To Stop Option ( 1- Disabled , 2 - Enabled) Y 1 1 2 Y
91.6 Set ATC ( 1 - ATC is not installed , 2 - ATC installed , 3 - Monitoring Enabled ) Y 1 1 3 Y
91.7 Grade Selection After Lamp Test Y 1 1 3 Y
Miscellaneous Protection Method ( 1- None , 2 - Mexico Security , 3 - Clear Last Transaction
91.8 Y 1 1 3 Y
Switch,)
91.9 Select Meter Model Type Y 1 1 1 Y
91.10 Hose Retraction(1- Pump without Hose Retraction , 2 - Pump with Hose Retraction) Y 1 1 2 Y
Set Totalizer( 1- Without Totalizer , 2 - Totalizer per Hose/Meter , 3 - Totalizer per Grade , 4 -
91.11 Y 1 1 4 Y
Totalizer related to the Pumping Unit/Motor)
91.12 Nozzle activated pump handle Y 1 1 2 Y
NOT USED NOT USED
To Set Vapor Recovery option ( 1- Without VRC , 2 - With VRC , 3 - With VRC and Monitoring
91.14 Y 1 1 5 Y
, 4 - With VRC and Re-regulation , 5 - VR Motor Control)
91.15 Set PPU Type( 1 - PPU per Product , 2 - PPU per Side) Y 1 1 2 Y
Set Lights ( 1 - Without Light , 2 - OPT Light - Two Wire(external control) , 2- OPT Light IFSF
91.16 Y 1 1 4 N
(internal control), 3 - Red Light Poland (Two wire),4 - Red Light)
Set UHF Unit Type for CC90 = 27,35,36,37,38,39( 1 - 120N40S , 2 - 120N40 , 3 - 120S , 4 -
91.17 Y 1 1 4 Y
91 120)
(SELECT NOT USED NOT USED
91.19 Set preset for LPG ( 1 - LPG Preset Disabled , 2 - LPG Preset Enabled ) Y 1 1 2 Y
INSTALLED
NOT USED NOT USED
OPTIONS) Set Tank Low Level Presence ( 1 - Set Tank Low Level Presence not Installed,2 - Set Tank Low
91.21 Level Presence installed with local handling, 3-Set Tank Low Level presence installed with Y 1 1 2 Y
remote handling)
Set Kiosk Switched Standalone Mode ( 1 - Kiosk Switched Stand Alone Mode not Present, 2 -
91.22 Y 1 1 4 Y
Kiosk Switched Stand Alone Mode Present)
91.23 Set Vapour Recovery Valves ( 1 - Valves not installed , 2 - Valves installed ) Y 1 1 2 N
NOT USED NOT USED
Set ATC Probe for LPG ( 1 - 1ATC Probe per Hydraulic , 2ATC Probe per Hydraulic, 3 - ATC
91.25 Y 1 1 3 Y
Probe for Australia)
91.26 Set protection for changing CC24 ( 1 - Disabled , 2 - Enabled ) Y 1 1 2 Y
91.27 Set internal Inter locking for Petrol/LPG/CNG ( 1 - Disabled , 2 - Enabled ) Y 1 1 2 Y
91.28 Set Adblues : Preset Valves ( 1 - Disabled , 2 - Enabled ) Y 1 1 2 N
91.29 Set Modbus ( 1 - Modbus Disabled , 2 - Modbus enabled) Y 1 1 6 Y
91.30 Set Pulser Error Function ( 1 - Major Error , 2 - Major Error , 3 - Medium Error) Y 1 1 3 N
UnAuthorized flow Error Function ( 1 - Minor Error , 2 - Medium Error , 3 - Medium Error
91.31 Y 1 1 3 N
with Two Wire Offline for 10 min)
To select South - Korea Rounding Method ( 1 - 0.100 Minimum , 2 - 0.075 Minimum , 3 -
91.32 Y 1 1 4 Y
0.050 Minimum , 4 - 0.030 Minimum)
Price Change method ( 1 - Price change immediately , 2 -Price change immediate with OIML
91.33 Y 1 1 2 Y
Delay)
91.34 DoorSwitch Option(1- Disable , 2 -LoggingOnly, 3 - Clear Last Transaction) Y 1 1 3 N
Set Pump Handle Configuration (1 - IS Pump Handles, 2 - PPU Pump Handles, 3-Both are
91.35 Y 3 1 3 N
valid).
91.36 Hydraulic Module with Satellite Nozzle(0-Disabled, 1-6 Hyd Grade) Y 1 0 6 Y
92
1 Set Side Exists (1 - Both Side , 2 - Single Side Left , 3 - Single Side Right) Y 1 1 3 Y
(SET SIDE EXISTS)
93 NOT USED
94 94.1.1 Fuel With a Zero PPU Disallowed Y
(SET ZERO PPU 94.1.2 Fuel with a Zero PPU Allowed Y 1 1 3 Y
OPTION) 94.1.2 Liter Counter (Combi Display Needed) Y
0 Function code Y 2 2 3 Y
To Set Country Code (Country code will Reset on Hardware Coldstart)
2 Y 0 0 999 Y
95 (Refer Appendix for Country Code Values)
Special Country Option ( 1 - Disabled , 2 - Thailand , 3 - Special Ecometer Test , 4 - Colombia ,
3 Y 1 1 5 Y
5 - Philippines)
96
(SET DISPENSER 0 To Set Dispenser Type ( 1 - Encore 500 , 5- Encore 500S ,7- Encore 700S) Y - 1 7 Y
TYPE)
Select Side of the Dispenser Y 1 1 4 Y
97 Select Nozzle (Product ) Number Y 1 1 6 Y
(SET SPECIAL To Set Special Nozzle Type ( 0 = Standard Nozzle , 1 = Reserve , 2 = LPG Nozzle Works as
NOZZLE 1 Dead Man Button, 3 = Reserve, 4 = 40/70 Button Select, 6 = LPG Nozzle with additional
CONFIGURATION Start/Stop Button,7 = AdBlue with VemmTec Meter , 8 = AdBlue with AdBlue-MassMeter, 9 = Y 0 0 10 Y
) CNG -Pkw, 10 = CNG - Bus)

98 NOT USED
99 NOT USED

Page 8
APPENDIX

Command Value Functional Details


75. X. Y 0 Invalid (default)
Where 1 Gasoline - North America (730)
X = sides 2 Diesel - North America (840)
0-6 3 Unleaded 90/92/95 – Europe (745)
Y = Value 4 Unleaded 98 – Europe (745)
5 Diesel – Europe (833)
6 Leaded Substitute 98 – Europe (755)
7 E85 Ethanol – Europe (785)
8 Lamp Oil – Europe (800)
9 Gas Oil – Europe (850)
10 Generic Uncompensated Fuel (1)
11 LPG – Europe (537)
12 Bio-Diesel – Europe (1)
13 Propane – Belgium (510)
14 Propane – UK (512)
15 E85 Ethanol without VR– Europe (785)
16 E0…E40 w. VR – Germany (888)
17 E60…E100 w. VR – Germany (888)
18 B0…B100 – Germany (888)

90 1 Grade 1
90 2 Grade1 , 2
90 3 Grade 1,2 ,3
90 4 Grade 1,2 ,3 ,4
90 27 Grade 1 and/or 1,2 (120N40S)
90 28 Grade 1,2,3,5,6
90 29 Grade 1,2,3,4,5,5,6
90 30 Grade 1,2 VK Button Select
90 31 Grade 1, 2 VK Button Select …. + Grade 3 DK
90 32 Grade 1 ,2 ,3 VK Button Select
90 33 Grade 1,2,3 VK Button Select .. + Grade 4 DK
90 34 Grade 1,2 VK Button Select…..+ Grade 3 4 DK
90 35 Grade 1,2 (120N40S)……………+Grade 5 (AdBlue)
90 36 Grade 1,2 (120N40S)………+Grade3
90 37 Grade 1,2 (120N40)……+Grade 3,4
90 38 Grade 1,2 (120N40S)……+Grade3 +Grade5(AdBlue)
90 39 Grade1,2(120N40)……….+Grade3,4 +Grade5(AdBlue)
90 41 Grade 1…………+Grade 5 ( LPG , AdBlue)
90 42 Grade 1,2………………..+Grade5 (LPG,AdBlue)
90 43 Grade1,2,3………..+Grade5(LPG,AdBlue)
90 44 Grade1,2,3,4….+Grade5(LPG,AdBlue)
90 51 Grade1………+Grade5 and/or 5,6(120N40S)
90 52 Grade1,2……………….+Grade5 and/or 5,6(120N40S)
90 53 Grade 1,2,3……….+Grade5 and/or5,6(120N40S)
90 54 Grade 1,2,3,4……………+Grade5 and/or 5,6 (120N40S)
90 77 Grade 1 and/or 1,2 (120N40S) …….+Grade5 and/or 5,6(120N40S)
90 80 Each Side : 1 Grade (397_G)
90 81 Each Side : 1 Grade (397_G)…………..Grade 1 (120N40S), Grade 2 (40S)

95.2 32 Argentina
95.2 36 Australia
95.2 56 Belgium
95.2 76 Brazil
95.2 124 Canada
95.2 156 China
95.2 170 Colombia
95.2 208 Denmark
95.2 246 Finland
95.2 250 France
95.2 276 Germany
95.2 300 Greece
95.2 336 VaticanCity
95.2 344 Hongkong
95.2 356 India
95.2 360 Indonesia
95.2 372 Ireland
95.2 376 Israel
95.2 380 Italy
95.2 392 Japan
95.2 410 South Korea
95.2 414 Kuwait
95.2 484 Mexico
95.2 528 Holland
95.2 554 New Zealand
95.2 578 Norway
95.2 616 Poland
95.2 634 Qatar
95.2 643 Russia
95.2 710 South Africa
95.2 724 Spain
95.2 752 Sweden
95.2 784 UAE
95.2 792 Turkey
95.2 826 Britain
95.2 840 USA
95.2 862 Venezuela