0% found this document useful (0 votes)
14 views6 pages

NewWPS Brochure 2007 ENG

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 6

TM

aquaMAX - Basic 360 Series


aquaMAXTM - Ultra 370 Series

> > Water Purification System


Water Purification System aquaMAXTM - Basic 360 Series

Various improved functions for superior


performance in your laboratory
aquaMAXTM - Basic 360 Series
with Reverse Osmosis Technology

Convenient Operation
Easy Maintenance
Refined Design
Quiet Operation
Alarm for Filter Replacement

Features of aquaMAXTM - Basic 360 Series


The highest water quality
- Easy to upgrade by adding R.O Post pack to produce Type Ⅱ water (ASTM)
- Auto-rinsing to keep constant water quality.
- Sensing Cell to display accurate water quality (Conductivity & Resistivity) by automatic temperature
compensation

Convenience for users


- One-touch clip type filters : Easy to replace filters by user
- Monitoring self test, filter replacement, Auto-rinsing and service check
- Separated modules for easy maintenance

Safety Function
- Pressure Regulator to prevent the instrument from damage by constant pressure.
- Pressure blocking: High and low pressure limit blocking for safe operation.

Attractive price
- The higher water quality you get, the lower cost we provide.

1 RO Membrane Pack
- When water passes through the filter, pure water is produced
by reverse osmosis
(Pack 1 : 10ℓ/H, Pack 2 : 20ℓ/H)
2 RO Pre Pack
1 2 3
- Removal of particles larger than 5um
- Filtering of chloride in tap water to protect RO Pack
3 RO Post Pack
- It reduces anions and cations as well as the level of remaining
organics.
TM
aquaMAX - Basic Flow Diagram
aquaMAXTM - Basic 360 Series

LED Lamp Water quality and performance


monitoring with alarm

Measure Conductivity & Resistivity Monitoring

Select Run the selected operation

Service Service function run (filter replacement etc.,)

Operate/Standby Selection of Operate/Standby

LCD Display Display of text message and value

TM
aquaMAX - Ultra Flow Diagram
aquaMAXTM - Ultra 370 Series
Water Purification System aquaMAXTM - Ultra 370 Series

The best choice for ideal water


quality in your lab.
aquaMAXTM - Ultra 370 Series

Convenient Operation
Easy Maintenance
Refined Design
Quiet Operation
Alarm for Filter Replacement

Features of aquaMAXTM - Ultra 370 Series


The highest water quality
- aquaMAXTM - Ultra produces TypeⅠgrade in electrical resistivity 18.2㏁·cm and TOC level to < 10 ppb.
- The water quality aquaMAXTM - Ultra complies with ASTM, CAP, ACS and NCCLS to be used with HPLC,
GC, IC, AAS, ICP and ICP - MS.
Resistivity Measurement
- Measuring the resistivity by automatic temperature compensation for accurate measurement
- Easy to select temp. compensation at your fingertips
▶ Ultra Pack
Ultra Pack
- Almost perfect removal of organic materials
- In applications such as HPLC, Cell-transmitter, Pharmacy and Labs
UF Filter
- Filtering various bacteria and impurities to reduce Pyrogen to 0.06 Eu/ml. ▶ UV Filter
▶ UF Filter
UV Filter
- Significantly low TOC level (< 5ppb) for preparation of analytical
grade reagents.
0.2㎛ Final Filter ▶ Final Filter
- Final filtering of impurities for produced water and prevention of contamination at drain

Simple Filter Replacement

▶ Filter can be simply replaced by user

▶ One-touch clip to prevent leakage


aquaMAXTM - Basic 360 Series aquaMAXTM - Ultra 370 Series

TM
aquaMAX - Basic 360 Series System
Model aquaMAXTM - Basic 360 aquaMAXTM - Basic 361 aquaMAXTM - Basic 362 aquaMAXTM - Basic 363
Part No. 3601011000 3601011001 3601011002 3601011003
Water grade TypeⅢwater/Standard TypeⅡwater/Standard TypeⅢwater/Extended capacity TypeⅡwater/Extended capacity
Productivity 10ℓ/H 10ℓ/H 20ℓ/H 20ℓ/H
- Ion removal 95~99% - Ion removal 95~99%
- Particle removal 99% - Particle removal 99%
Water Quality - Bacteria removal 99.99% 1~15 ㏁·cm - Bacteria removal 99.99% 1~15 ㏁·cm
- Pyrogen removal 99% - Pyrogen removal 99%
- Organics removal 99% - Organics removal 99%

Pretreatment ∨ ∨ ∨ ∨
Filter
Reverse Osmosis ∨ ∨ ∨ ∨
Type
Ion exchange ∨ ∨
Feed water requirement PH : 3~10, TDS : lower than 500ppm, Temp : 4~35℃, Pressure : 1~5Kg/cm2, Turbidity : 1.0 NTU
Environment Requirement Temp : 5~40℃, Humidity : 20~80%
- Washing/Rinsing - Same as Basic 360 - Washing/Rinsing - Same as Basic 362
- Autoclaves - Buffer and Media - Autoclaves - Buffer and Media
- Steam Generators Preparation, Electro- - Steam Generators Preparation, Electro-
Applications phoresis phoresis
- Feed Water for Ultra- - Feed Water for Ultra-
Pure Water Pure Water

TM
aquaMAX - Ultra 370 Series System
aquaMAXTM - Ultra 370 aquaMAXTM - Ultra 371 aquaMAXTM - Ultra 372 aquaMAXTM - Ultra 373
Model (Standard) (UF Version) (UV Version) (UV/UF Version)
Part No. 3701011000 3701011001 3701011002 3701011003
Reagents, Mammalian cell culture, Including
General analysis, DNA sequencing, Ultra-trace inorganic and all applications of UV
Application IC, AAS, HPLC, ICP-MS, Electrophoresis, organic analysis, and UF version, PCR,
Standard solvents and Monoclonal antibody GC-MS and TOC analysis 2-dimensional eletrophoresis,
buffer solutions production cell culture

Resistivity(at 25℃) 18.2㏁·cm 18.2㏁·cm 18.2㏁·cm 18.2㏁·cm


TOC 5~10 ppb 5~10 ppb 1~5 ppb 1~5 ppb
Pyrogen - < 0.06 Eu/ml - < 0.06 Eu/ml
Flow Rate(Max) 1.5ℓ/min 1.5ℓ/min 1.5ℓ/min 1.5ℓ/min
The specipication is subject to change depending on the water quality of feedwater.

Ultra-pure/Pure Water Purification System Package

Reservoir level sensor

Produced pure
water

ater for
Feed wure water
ultra - p

▶ aquaMAXTM- Basic 361 or 363 PE Tank ▶ aquaMAXTM- Ultra 370 Series


These products are manufactured in the Young Lin
ISO 9001 - certified facility that is periodically
audited by the registering body to ensure compliance

Date : March, 2007

Young Lin Bldg., 899-6 Hogye-dong, Anyang, 431-836, Korea


TEL : +82-31-428-8700 FAX : +82-31-428-87 79
E-Mail : [email protected]
Website : ht tp://www.y ounglin.com