0% found this document useful (0 votes)
31 views5 pages

BP220

Uploaded by

hazboonalastor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views5 pages

BP220

Uploaded by

hazboonalastor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Bp 220

Study online at https://quizlet.com/_2c53nw


House and lot Bp 220 shall apply to the development of either a ___ and ____
House or lot only or ______
A. Protection and safety of life, limb, property, general public
B. Basic needs of human settlement
Design standards for bp 220
C. Affordability
D. Location
Water
Movement/ circulation
Storm drainage
Basic needs of human settlement
Solid/liquid waste disposal
Parks and playground
Power
Refers to the most reasonable price of land and shelter based on
Affordable cost
the needs and financial capability of program beneficiaries and
Ra 7279
appropriate financing scheme
Suitable trees with a caliper of ___ or more, shrubs and desired
200mm
ground cover shall be preserved
Good quality of soil shall not be removed and shall be presrved for
Finishing grades of yards playgrounds parks and garden area
__
Grass, shrubs and other landscsping materials for ground cover
Complete and permanent cover of the area
shall be planted as to allow ___
Fault traces Philvolcs resolution no.515, series of 1992
Hierarchy, accessibility, free from hazards risks barriers Location of parks shall be based on
Bp344 Land circulation system shall comply with the pertinent req. Of
If major road will function as interconnecting road, it shall have a
10m; 15cm min row of__; it shall have a ___mix gravel / pit run base course
on well compacted sub grade.
Subdivision projects abutting a main public road must provide
3m depth; 5m lengt sufficient setbacks with minimum dimension of __ in depth and __
in length at both sides of the subdivision entrance.
Width of 2m intended to break a block and to serve both pedes-
Alley; 2m trians and for emergency purposes; shall not be used as access
to property
Width 3m; provide pedestrian access to property for socialized
Pathwalk; 3m width; 60m max length
housing projects; max length ___
Pd 953 tree planting Planting strips are required under _____
Every owner of existing subdivision is required among others to
Resolution no. R-532 series of 1993
plant trees in designated area
Asphalt- 50mm
Major, minor road and motor court for economic and socialized
Concrete-150mm
housing shall be paved with ____
Compressive strength: 20.7 mpa at 28 days
Macadam finish Finish for sidewalk and alley
Distance between offset intersections should not be less than
20m
___corner to corner.
6m Radius of outer curb of cul de sac near road
4.5m Radius of inner curb of cul de sac
21 to 31m Diameter of cul de sac
1.5 to 9% Crown of the road shall have a slope of not less than _____.
Price of saleable lots intended for single detached units shall not
40%
exceed ___ of max selling price of the house and lot package
Row houses shall be __ units per block or cluster but in no case
20 units per block; 100m max length
this be more than _____ in length

1/5
Bp 220
Study online at https://quizlet.com/_2c53nw
400m Max block length
2m alley If block exceeds 250m, a ___approximately at mid length
1.5m front and side setback
Setbacks for socialized and economic housing
2 m rear setback
300m Communal well shall not be closer than ____ from each other
150 liters per capita per day Minimun quality of water consumption for subdivision project
Each subdivision must have at least an ____ and ___ with suffi-
Operationa Deep well and pump sets cient capacity to provide average daily demand to all home owners
provided a spare pump and motor set is reserved
Required permits from the ____ shall be obtained and standards
NWRB; LWUA
of ___ shall be complied with
Ground reservoir shall be at least ___ from sources of pollution /
25m
contaminants
20% of average daily demand plus fire reserve Water tank capacity
50m Distance of street lighting per pole
Concrete lined canal with load bearing cover Minimum drainage system for economic and socialized housing
300mm Minimum drainage pipe
Row = 15m
1.3m Planting strip=?
Sidewalk = 1.20m
Row= 12m, 10m
0.80m Planting strip=?
Sidewalk=1.20
Row= 8m
0.40m Planting strip=?
Sidewalk=0.60m
Row = 6.5
Optional Planting strip=?
Sidewalk=0.50m
2m Minimum horizontal dimension of courts and yards
1.20m Passageway with a minimum width of ___ or by a door thru room
50% residential
Private open space req. For interior lot
24% others
20% residential Private open space req.
15% others For inside lot
10% residential Private open space req.
5% others For corner and through lot
5% residential Privats open space req.
5% others For lots bounded on 3 or more sides
1 hour resistivity rating Minimum firewall fire resistivity rating
2m Min ceiling height bp220
1.80 above and below Min ceiling height mezzanine
50% of floor area Mezzanine floor area
1 for less than 10 people
Min number of entrances
2 for more than 10 people
2m; 1.8m for bathroom Min clear height of doors
Main door 0.80m
Service/Bedroom 0.70m Min clear width of doors
Bathroom 0.60m
0.60m Min clear width of stairs
2/5
Bp 220
Study online at https://quizlet.com/_2c53nw
250mm Max. Riser of stairs
200mm Minimum tread of stairs exclusive of any projections
2m Head room clearance for stairs
3.6m Max height between landings
1 At least how many handrails?
4 Stairways with less than __risers need not to have handrails
0.80m to 1.20m Handrail height
38mm Handrail Clearance from wall
150mm, 300mm from the narrower side of stairs Min width of winding and circular stair
1.80m Max distance between landings of ladders
5mm Max variation of risers and treads
At least 1 light outlet and 1 convenience outlet per activity area Electrical requirements
Multifamily dwellings and condominiums for socialized and eco-
25% of total area nomic housing : non residential areas shall be equal and not more
than ___?
Minimum distance between buildings with morethan 4 storeys
10m; 6m
shall be __? Minimum horizontal clearance shall be ___.
In cases when 2 sides of the buildings facing each other are blank
walls, either there are no openings or only minimal openings for
2m; 1m
comfort rooms, the minimum distance between bldgs shall be ___.
Horizontal distance between eaves
Measurement of distance between 2 blgs shall be made where the
Shortest
distance between the 2 buildings is ___.
1 parking slot per 8 living units Parking requirement for multifamily dwellings and condominiums
2.15m x 6.00m Parallel and diagonal parking
2.50m x 5.00m Perpendicular parking
5m Driveway right of way
Offsite parking allowed provided further that it shall not be ___
100m
away from condominium projecy
Automativ fire alarm suppression system should be provided for
15m
structure more than ___ in height
6 storeys and beyond Provision of elevators required for buildings ______
Use of indigenous materials are encouraged as long as it con-
25 years forms with the rules and ensures a building life span of at least
____.
Board resolution no. R-97 series of 1982 annex 2 Variances and exemptions for bp 220 is stipulated in ____.
Individual lot owners in bp220 may construct their individual res-
Sangguniang bayan or sangguiniang panglunsod; city/ municipal idential house by: 1. Development approval is secured from LGU
engineer thru _____ prior to construction. 2. Proposed building plans are
submitted to the ____ for approval
Every registered owner or developer of a parcel of land who
Hlurb or lgu wishes to convert the same into a subdivision projecy shall apply
with ____ or _____ for approval
2 sets of sdp
1:200 to 1:2000 signed by architect, enp, civil engineer or geodetic Optional application for preliminary subdivion development plan
engineer
Signed by geodetic engr
500m Vicinity map- at least within ____from the property boundaries of
the projecy

3/5
Bp 220
Study online at https://quizlet.com/_2c53nw
Ground elevation for subdivision if less than 2% spot elevations
25m apart in all direction; 0.50m point not more than ___; more than 2% indicate contours not more
than ____ if necrssary due to irregular land
Approval of preliminary subdivision development plans will be
180 days
valid only for a period of ____ from the date of approval
1:200
1:1000 Subdivision development plan scales
Max 1:2000
Site development plan shall be prepared signed and sealed by any
Architect, enp, civil engineer or geodetic engineer
licensed and registered _____
Should a pump motor has a horsepower rating of 50hp or more,
Professional mechanical engineer
its pump rating and specs shall be signed by a ___?
National water resources board nwrb Application for permit to drill from____.
30hec and above Traffic impact assessment for projects ____ are required
Development permit shall only be valid for a period of ____ from
3 years
the date of issue if no physical development is introduced
Licensed geodetic engineer Land surveys
Pd 1529
Property rrgistration decree
Ra 8560 irr
Licensed to sell
Hlurb form 001
Sworn registration statements for corporation
Licensed to sell
Hlurb form 003
Sworn registration statement for single proprietorship
A ______ billboard notice of the project shall be posted on the
3'x 6' billboard
project site until the issuance of the license to sell
Failure to publish the notice of filling of registratin statement within
2 weeks ____ from the receipt to publish issued by board, owner shall be
required to refile the application for certificate of registration
After ___ days from the completion of publication, the board shall
5 days
issue a certificate of registration
Within ___ from registration of the project, no owner or developer
2 weeks shall sell any disposable subdivision lots or condo in a registered
property without a license to sell by the board
10% of development cost of unfinished portion of the approved
Surety bond
plan
At least 10% of the total development cost Real estate mortgages
Cash bonds
Fiduciary deposits
5% of the development cost of the unfinished portion of the ap-
Guarantee deposit
proved plan which may be in the form of:
Letter from bank
Irrevocable credit line to be utilized in the devt
July 12 1993 Presidential decree 953 was approved when?
The developer shall be relieved of the obligation to maintain trees
planted only upon the issuance of a ___ by hlurb and upon receipt
Certificate of completion; deed of donation for the road lot and
by lgu concerning the ____ duly executed in their favor on the
open spaces
homeowners association in the case of parks and playground with
consent of local government
July 6 1976 Existing subdivision approved after ____.
Amended pd 953
Memorandum circular no. 29
Supplemental rules and regulations to implement pd 953 admin-
Series of 2005 july 19
istrative order no. 2 series of 1994

Shade trees

4/5
Bp 220
Study online at https://quizlet.com/_2c53nw
Large trees with profused branches, extended laterally, min 4m
height
Ornamental tree Medium sized trees with less profused branches, max height 3m
Garden plants Single woody stem plants which do not have primary branches
Along the side; electrical power distribution lines; 5m recommend- Shade trees shall be planted ___ of the road opposite the ______.
ed distance Recommended distance between shade trees
Ornamental trees shall be planted_____. Recommended distance
Along side of the electrical power distribution lines; 3m
between ornamental trees
Vertical clearance from topmost part of the ornamental trees to
3m
primary electrical power distribution lines
Coconut and other high growing plants Shall not be allowed in all designated planting strips
1m in height for higher plant survival Recommended potted planting materials is at least ___.
1 tree per saleable lot Ratio of trees in subdivisions
Evaluation of applications for the integrated permit by hsrc per-
Resolution no. 55 series 1982 of executive committee
sonnel
Pd 957 Subdivision and condominuim buyers protective decree
Pd 1216 Defining open spaces
56cm least dimension; 0.45 sqm; 122cm Pd 1185 outside window dimension; height from ffl
Pd 1185: No exit access from sleeping rooms to outside shall be
90 cm wide
less than_.
60cm wide Pd 1185: Interior door providing exit less than

5/5

You might also like