02 Cooling System
02 Cooling System
02 Cooling System
2
●Air is sucked from outer side of vehicle. It is opposite to Bulldozer or Wheel
loader.
・In case of bulldozer and wheel loader, air is sucked from inner side.
・Hydraulic motor and pipes are installed downstream to prevent the oil from attaching on the radiator core.
3
Hydraulic Circuit
5
Control Map ( by temperatures )
6
Control Map ( by engine speed )
Controller chooses the lower one from the highest one of temperatures or another
one on the engine speed map. Even when 100% speed decided by temperatures,
Controller lowers fan speed at low engine speed same as the conventional
mechanical drive fan.
7
Fan Pump Swash Plate Control
9
Cooling Fan Motor ( LPV90 )
1. Output shaft
2. Case
3. Thrust plate
4. Piston ass’y
5. Cylinder block
6. Valve plate
7. Cover
8. Spring
9. Suction valve
10. Pilot valve
11. Spool for
reverse
12. Safety valve
10
Cooling Fan Motor ( LPV90 )
1. When starting to rotate 2. When stopping
Suction valve
・Pump pressure(P) flows into MA port and ・When pressure doesn’t come, fan motor is
rises to increase rotation speed. Oil is drained gradually going slow down. In case of Fan is
to tank from Outlet port MB. rotated by inertia, oil is supplied from MB to MA
through suction valve to prevent cavitation.
11
Safety Valve
Setting pressure
24.5Mpa{250kg/cm²}
12
Reversible Valve
1. When On-Off solenoid is OFF 2. When On-Off solenoid is ON
Motor rotates clockwise Motor rotates counterclockwise
In the Fan reverse mode Fan speed is getting down automatically to soften the reversing shock. In
case of Bulldozer engine should be stopped .Then reverse mode starts after Key SW ON.
14
Fan 100% Mode
*~#55045
EPC valve
Pump discharge
Case drain
16
Main Pump (Reference)
To EPC valve
To sequence
valve
To PPC
valve Checking port
for front pump
Checking port pressure
for rear pump To PPC valve
pressure
17