Snap-shot of the

ISO 11783-11 online data base

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 2/572

DD Entity 0 - Internal Data Base DDI


Definition This DDI is reserved for internal use only.
Comment This DDE was a result of Jan 2005 Task Controller meeting.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol not defined - not defined
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2005-02-02
Status Comments

DD Entity 1 - Setpoint Volume Per Area Application Rate as [mm³/m²]


Definition Setpoint Application Rate specified as volume per area as
[mm³/m²]
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m² - Capacity per area unit
Resolution 0,01
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,00 - 21474836,47
Submit by Part 10 Task Force
Submit Date 0000-00-00
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 3/572

DD Entity 2 - Actual Volume Per Area Application Rate as [mm³/m²]


Definition Actual Application Rate specified as volume per area as [mm³/m²]
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m² - Capacity per area unit
Resolution 0,01
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,00 - 21474836,47
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 3 - Default Volume Per Area Application Rate as [mm³/m²]


Definition Default Application Rate specified as volume per area as [mm³/m²]
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m² - Capacity per area unit
Resolution 0,01
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,00 - 21474836,47
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 4/572

DD Entity 4 - Minimum Volume Per Area Application Rate as [mm³/m²]


Definition Minimum Application Rate specified as volume per area as
[mm³/m²]
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m² - Capacity per area unit
Resolution 0,01
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,00 - 21474836,47
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 5 - Maximum Volume Per Area Application Rate as [mm³/m²]


Definition Maximum Application Rate specified as volume per area as
[mm³/m²]
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m² - Capacity per area unit
Resolution 0,01
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,00 - 21474836,47
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 5/572

DD Entity 6 - Setpoint Mass Per Area Application Rate


Definition Setpoint Application Rate specified as mass per area
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 7 - Actual Mass Per Area Application Rate


Definition Actual Application Rate specified as mass per area
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 6/572

DD Entity 8 - Default Mass Per Area Application Rate


Definition Default Application Rate specified as mass per area
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 9 - Minimum Mass Per Area Application Rate


Definition Minimum Application Rate specified as mass per area
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 7/572

DD Entity 10 - Maximum Mass Per Area Application Rate


Definition Maximum Application Rate specified as mass per area
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 11 - Setpoint Count Per Area Application Rate


Definition Setpoint Application Rate specified as count per area
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 8/572

DD Entity 12 - Actual Count Per Area Application Rate


Definition Actual Application Rate specified as count per area
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 13 - Default Count Per Area Application Rate


Definition Default Application Rate specified as count per area
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 9/572

DD Entity 14 - Minimum Count Per Area Application Rate


Definition Minimum Application Rate specified as count per area
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 15 - Maximum Count Per Area Application Rate


Definition Maximum Application Rate specified as count per area
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 10/572

DD Entity 16 - Setpoint Spacing Application Rate


Definition Setpoint Application Rate specified as distance: e.g. seed spacing of
a precision seeder
Comment Handling 0 value for Seed Spacing -
The 0 rate indicates nothing shall be applied. Even though Seed
spacing defines distance between 2 Seeds. As this is rate DDI, zero
value shall indicate no Seeds are applied for Rate Application.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status Published
Status Date 2020-12-15
Status Comments Comment added

DD Entity 17 - Actual Spacing Application Rate


Definition Actual Application Rate specified as distance: e.g. seed spacing of a
precision seeder
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 11/572

DD Entity 18 - Default Spacing Application Rate


Definition Default Application Rate specified as distance: e.g. seed spacing of a
precision seeder
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 19 - Minimum Spacing Application Rate


Definition Minimum Application Rate specified as distance: e.g. seed spacing of
a precision seeder
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 12/572

DD Entity 20 - Maximum Spacing Application Rate


Definition Maximum Application Rate specified as distance: e.g. seed spacing
of a precision seeder
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 21 - Setpoint Volume Per Volume Application Rate


Definition Setpoint Application Rate specified as volume per volume
Comment
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
Unit Symbol mm³/m³ - Capacity per capacity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 13/572

DD Entity 22 - Actual Volume Per Volume Application Rate


Definition Actual Application Rate specified as volume per volume
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m³ - Capacity per capacity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 23 - Default Volume Per Volume Application Rate


Definition Default Application Rate specified as volume per volume
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m³ - Capacity per capacity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 14/572

DD Entity 24 - Minimum Volume Per Volume Application Rate


Definition Minimum Application Rate specified as volume per volume
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m³ - Capacity per capacity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 25 - Maximum Volume Per Volume Application Rate


Definition Maximum Application Rate specified as volume per volume
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/m³ - Capacity per capacity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 15/572

DD Entity 26 - Setpoint Mass Per Mass Application Rate


Definition Setpoint Application Rate specified as mass per mass
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 27 - Actual Mass Per Mass Application Rate


Definition Actual Application Rate specified as mass per mass
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 16/572

DD Entity 28 - Default Mass Per Mass Application Rate


Definition Default Application Rate specified as mass per mass
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 29 - Minimum Mass Per Mass Application Rate


Definition Minimum Application Rate specified as mass per mass
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 17/572

DD Entity 30 - MaximumMass Per Mass Application Rate


Definition Maximum Application Rate specified as mass per mass
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 31 - Setpoint Volume Per Mass Application Rate


Definition Setpoint Application Rate specified as volume per mass
Comment
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 18/572

DD Entity 32 - Actual Volume Per Mass Application Rate


Definition Actual Application Rate specified as volume per mass
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
9 - Forage harvester
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added device class 9 - Forage Harvester

DD Entity 33 - Default Volume Per Mass Application Rate


Definition Default Application Rate specified as volume per mass
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 19/572

DD Entity 34 - Minimum Volume Per Mass Application Rate


Definition Minimum Application Rate specified as volume per mass
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 35 - Maximum Volume Per Mass Application Rate


Definition Maximum Application Rate specified as volume per mass
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 20/572

DD Entity 36 - Setpoint Volume Per Time Application Rate


Definition Setpoint Application Rate specified as volume per time
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 37 - Actual Volume Per Time Application Rate


Definition Actual Application Rate specified as volume per time
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 21/572

DD Entity 38 - Default Volume Per Time Application Rate


Definition Default Application Rate specified as volume per time
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 39 - Minimum Volume Per Time Application Rate


Definition Minimum Application Rate specified as volume per time
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 22/572

DD Entity 40 - Maximum Volume Per Time Application Rate


Definition Maximum Application Rate specified as volume per time
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 41 - Setpoint Mass Per Time Application Rate


Definition Setpoint Application Rate specified as mass per time
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 23/572

DD Entity 42 - Actual Mass Per Time Application Rate


Definition Actual Application Rate specified as mass per time
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 43 - Default Mass Per Time Application Rate


Definition Default Application Rate specified as mass per time
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 24/572

DD Entity 44 - Minimum Mass Per Time Application Rate


Definition Minimum Application Rate specified as mass per time
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 45 - Maximum Mass Per Time Application Rate


Definition Maximum Application Rate specified as mass per time
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 25/572

DD Entity 46 - Setpoint Count Per Time Application Rate


Definition Setpoint Application Rate specified as count per time
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 47 - Actual Count Per Time Application Rate


Definition Actual Application Rate specified as count per time
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 26/572

DD Entity 48 - Default Count Per Time Application Rate


Definition Default Application Rate specified as count per time
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 49 - Minimum Count Per Time Application Rate


Definition Minimum Application Rate specified as count per time
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 27/572

DD Entity 50 - Maximum Count Per Time Application Rate


Definition Maximum Application Rate specified as count per time
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 51 - Setpoint Tillage Depth


Definition Setpoint Tillage Depth of Device Element below soil surface, value
increases with depth. In case of a negative value the system will
indicate the distance above the ground.
Comment
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
8 - Root Harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 28/572

DD Entity 52 - Actual Tillage Depth


Definition Actual Tillage Depth of Device Element below soil surface, value
increases with depth. In case of a negative value the system will
indicate the distance above the ground.
Comment
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

DD Entity 53 - Default Tillage Depth


Definition Default Tillage Depth of Device Element below soil surface, value
increases with depth. In case of a negative value the system will
indicate the distance above the ground.
Comment Use when missing Position data or outside any Treatment Zone
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
8 - Root Harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 29/572

DD Entity 54 - Minimum Tillage Depth


Definition Minimum Tillage Depth of Device Element below soil surface, value
increases with depth. In case of a negative value the system will
indicate the distance above the ground.
Comment Supplied by device as physical minimum
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
8 - Root Harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

DD Entity 55 - Maximum Tillage Depth


Definition Maximum Tillage Depth of Device Element below soil surface, value
increases with depth. In case of a negative value the system will
indicate the distance above the ground.
Comment Supplied by device as physical maximum
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
8 - Root Harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 30/572

DD Entity 56 - Setpoint Seeding Depth


Definition Setpoint Seeding Depth of Device Element below soil surface, value
increases with depth
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 57 - Actual Seeding Depth


Definition Actual Seeding Depth of Device Element below soil surface, value
increases with depth
Comment
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 31/572

DD Entity 58 - Default Seeding Depth


Definition Default Seeding Depth of Device Element below soil surface, value
increases with depth
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 59 - Minimum Seeding Depth


Definition Minimum Seeding Depth of Device Element below soil surface, value
increases with depth
Comment supplied by device as physical minimum
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 32/572

DD Entity 60 - Maximum Seeding Depth


Definition Maximum Seeding Depth of Device Element below soil surface, value
increases with depth
Comment supplied by device as physical maximum
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 61 - Setpoint Working Height


Definition Setpoint Working Height of Device Element above crop or soil
Comment
Typically used by Device 0 - Non-specific system
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 33/572

DD Entity 62 - Actual Working Height


Definition Actual Working Height of Device Element above crop or soil
Comment This is the height above the effective control surface. For sprayers
this is the height above the crop canapé and for fertilizer spreaders,
harvesters, etc it is the height above the ground.
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added comment for clarification.

DD Entity 63 - Default Working Height


Definition Default Working Height of Device Element above crop or soil
Comment use when missing Position data or outside any Treatment Zone
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 34/572

DD Entity 64 - Minimum Working Height


Definition Minimum Working Height of Device Element above crop or soil
Comment supplied by device as physical minimum
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 65 - Maximum Working Height


Definition Maximum Working Height of Device Element above crop or soil
Comment supplied by device as physical maximum
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 35/572

DD Entity 66 - Setpoint Working Width


Definition Setpoint Working Width of Device Element
Comment
Typically used by Device 0 - Non-specific system
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 67 - Actual Working Width


Definition Actual Working Width of Device Element
Comment This is the effective / active working width during operation.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 36/572

Submit Date 2003-08-01


Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added comment for clarification.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 37/572

DD Entity 68 - Default Working Width


Definition Default Working Width of Device Element
Comment
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 69 - Minimum Working Width


Definition Minimum Working Width of Device Element
Comment
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 38/572

Current Status ISO-Published


Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 39/572

DD Entity 70 - Maximum Working Width


Definition Maximum Working Width of Device Element
Comment
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 71 - Setpoint Volume Content


Definition Setpoint Device Element Content specified as volume
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 40/572

DD Entity 72 - Actual Volume Content


Definition Actual Device Element Content specified as volume
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 73 - Maximum Volume Content


Definition Maximum Device Element Content specified as volume
Comment is a minimum needed as well ??
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 41/572

Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 42/572

DD Entity 74 - Setpoint Mass Content


Definition Setpoint Machine Element Content specified as mass
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol g - Mass large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 75 - Actual Mass Content


Definition Actual Device Element Content specified as mass
Comment If the device is equipped with a weighing system which provides the
possibility to tare the current load it is possible that the value has a
negative sign in case of an unload operation.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol g - Mass large
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 43/572

Current Status ISO-Published


Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 44/572

DD Entity 76 - Maximum Mass Content


Definition Maximum Device Element Content specified as mass
Comment is a minimum needed as well ??
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol g - Mass large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 77 - Setpoint Count Content


Definition Setpoint Device Element Content specified as count
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 45/572

Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 46/572

DD Entity 78 - Actual Count Content


Definition Actual Device Element Content specified as count
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 79 - Maximum Count Content


Definition Maximum Device Element Content specified as count
Comment is a minimum needed as well ??
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 47/572

DD Entity 80 - Application Total Volume as [L]


Definition Accumulated Application specified as volume as liter [L]
Comment is a counter of a device element
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol L - Capacity count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 81 - Application Total Mass in [kg]


Definition Accumulated Application specified as mass in kilogram [kg]
Comment is a counter of a device element
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol kg - Mass
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 48/572

DD Entity 82 - Application Total Count


Definition Accumulated Application specified as count
Comment Task total of a device element for the application of a countable
product. Often used as total for the group Setpoint, Actual, Default,
Minimum & Maximum Count Per Area Application Rate (DDI 11
through 15). This DDI is meant for countable products.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2022-08-09
Status Comments Comment update only!

DD Entity 83 - Volume Per Area Yield


Definition Yield as volume per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ml/m² - Capacity per area large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 49/572

DD Entity 84 - Mass Per Area Yield


Definition Yield as mass per area, not corrected for the reference moisture
percentage DDI 184.
Comment This Mass per Area yield is the mass that includes the actual
percentage moisture (DDI 99) if this is measured on e.g. harvesting
equipment. This comment is added to clarify and differentiate this DDI
from the Dry Mass Per Area Yield (DDI 181).
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 85 - Count Per Area Yield


Definition Yield as count per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 50/572

DD Entity 86 - Volume Per Time Yield


Definition Yield as volume per time
Comment
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol ml/s - Float large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 87 - Mass Per Time Yield


Definition Yield as mass per time, not corrected for the reference moisture
percentage DDI 184.
Comment This Mass per Time yield is the mass that includes the actual
percentage moisture (DDI 99) if this is measured on e.g. harvesting
equipment. This comment is added to clarify and differentiate this DDI
from the Dry Mass Per Time Yield (DDI 182).
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 51/572

DD Entity 88 - Count Per Time Yield


Definition Yield as count per time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 89 - Yield Total Volume


Definition Accumulated Yield specified as volume
Comment is a counter of a machine element
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol L - Quantity per volume
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 52/572

DD Entity 90 - Yield Total Mass


Definition Accumulated Yield specified as mass, not corrected for the reference
moisture percentage DDI 184.
Comment This Yield Total Mass is the mass that includes the average
percentage moisture (DDI 262) if this is measured on e.g. harvesting
equipment. This comment is added to clarify and differentiate this DDI
from the Yield Total Dry Mass (DDI 183).
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 91 - Yield Total Count


Definition Accumulated Yield specified as count
Comment is a counter of a machine element
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 53/572

DD Entity 92 - Volume Per Area Crop Loss


Definition Crop yield loss as volume per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ml/m² - Capacity per area large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 93 - Mass Per Area Crop Loss


Definition Crop yield loss as mass per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 54/572

DD Entity 94 - Count Per Area Crop Loss


Definition Crop yield loss as count per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol /m² - Quantity per area unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 95 - Volume Per Time Crop Loss


Definition Crop yield loss as volume per time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ml/s - Float large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 55/572

DD Entity 96 - Mass Per Time Crop Loss


Definition Crop yield loss as mass per time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 97 - Count Per Time Crop Loss


Definition Crop yield loss as count per time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 56/572

DD Entity 98 - Percentage Crop Loss


Definition Crop yield loss
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 99 - Crop Moisture


Definition Moisture in crop yield
Comment This DDE defines the actual percentage moisture of the crop.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 57/572

DD Entity 100 - Crop Contamination


Definition Dirt or foreign material in crop yield
Comment This DDE defines the contamination in ratio of the yield DDI units.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 101 - Setpoint Bale Width


Definition Setpoint Bale Width for square baler or round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 58/572

DD Entity 102 - Actual Bale Width


Definition Actual Bale Width for square baler or round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 103 - Default Bale Width


Definition Default Bale Width for square baler or round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 59/572

DD Entity 104 - Minimum Bale Width


Definition Minimum Bale Width for square baler or round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 105 - Maximum Bale Width


Definition Maximum Bale Width for square baler or round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 60/572

DD Entity 106 - Setpoint Bale Height


Definition Setpoint Bale Height is only applicable to square baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 107 - ActualBaleHeight


Definition Actual Bale Height is only applicable to square baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 61/572

DD Entity 108 - Default Bale Height


Definition Default Bale Height is only applicable to square baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 109 - Minimum Bale Height


Definition Minimum Bale Height is only applicable to square baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 62/572

DD Entity 110 - Maximum Bale Height


Definition Maximum Bale Height is only applicable to square baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 111 - Setpoint Bale Size


Definition Setpoint Bale Size as length for a square baler or diameter for a
round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 63/572

DD Entity 112 - Actual Bale Size


Definition Actual Bale Size as length for a square baler or diameter for a round
baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 113 - Default Bale Size


Definition Default Bale Size as length for a square baler or diameter for a round
baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 64/572

DD Entity 114 - Minimum Bale Size


Definition Minimum Bale Size as length for a square baler or diameter for a
round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 115 - Maximum Bale Size


Definition Maximum Bale Size as length for a square baler or diameter for a
round baler
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 65/572

DD Entity 116 - Total Area


Definition Accumulated Area
Comment is a counter of a machine element
Typically used by Device 0 - Non-specific system
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
15 - Municipal Work
Unit Symbol m² - Area
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 117 - Effective Total Distance


Definition Accumulated Distance in working position
Comment is a counter of a machine element
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 66/572

Display Range 0 - 2147483647


Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 67/572

DD Entity 118 - Ineffective Total Distance


Definition Accumulated Distance out of working position
Comment is a counter of a machine element
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 119 - Effective Total Time


Definition Accumulated Time in working position
Comment is a counter of a machine element
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
17 - Sensor System
Unit Symbol s - Time count

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 68/572

Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status ISO-Published
Status Date 2011-12-21
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 69/572

DD Entity 120 - Ineffective Total Time


Definition Accumulated Time out of working position
Comment is a counter of a machine element
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol s - Time count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 121 - Product Density Mass Per Volume


Definition Product Density as mass per volume
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 70/572

Display Range 0 - 2147483647


Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 71/572

DD Entity 122 - Product Density Mass PerCount


Definition Product Density as mass per count
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol mg/1000 - 1000 seed Mass
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 123 - Product Density Volume Per Count


Definition Product Density as volume per count
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml/1000 - Volume per quantity unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Part 10 Task Force
Submit Date 2003-08-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 72/572

Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 73/572

DD Entity 124 - Auxiliary Valve Scaling Extend


Definition Factor to apply to AuxValveCommand PortFlowCommand. The
scaling of the port flow relates to flow, not to spool position, although
the position of the spool is of course indirectly affected.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol % - Percent
Resolution 0,1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 125 - Auxiliary Valve Scaling Retract


Definition Factor to apply to AuxValveCommand PortFlowCommand. The
scaling of the port flow relates to flow, not to spool position, although
the position of the spool is of course indirectly affected.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol % - Percent
Resolution 0,1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 74/572

DD Entity 126 - Auxiliary Valve Ramp Extend Up


Definition The valve will apply a ramp to the Auxiliary ValveCommand
PortFlowCommand, to limit the acceleration or deceleration of flow.
The valve must apply the ramp to create a liniear increase/decrease
of flow over time.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol ms - Time
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 127 - Auxiliary Valve Ramp Extend Down


Definition The valve will apply a ramp to the Auxiliary ValveCommand
PortFlowCommand, to limit the acceleration or deceleration of flow.
The valve must apply the ramp to create a liniear increase/decrease
of flow over time.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol ms - Time
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 75/572

DD Entity 128 - Auxiliary Valve Ramp Retract Up


Definition The valve will apply a ramp to theAuxiliary ValveCommand
PortFlowCommand, to limit the acceleration or deceleration of flow.
The valve must apply the ramp to create a liniear increase/decrease
of flow over time.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol ms - Time
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 129 - Auxiliary Valve Ramp Retract Down


Definition The valve will apply a ramp to the Auxiliary ValveCommand
PortFlowCommand, to limit the acceleration or deceleration of flow.
The valve must apply the ramp to create a liniear increase/decrease
of flow over time.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol ms - Time
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 76/572

DD Entity 130 - Auxiliary Valve Float Threshold


Definition Safety function. Current output of valve must be above threshold
before float command is allowed.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol % - Percent
Resolution 0,1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 131 - Auxiliary Valve Progressivity Extend


Definition Define non-linear releationship between command and flow by 2nd
degree polynomium. (I will get polynomium)
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 77/572

DD Entity 132 - Auxiliary Valve Progressivity Retract


Definition Define non-linear releationship between command and flow by 2nd
degree polynomium. (I will get polynomium)
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 133 - Auxiliary Valve Invert Ports


Definition Tell valve to swap extend and retract ports, easier than redoing
plumbing on valve
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Lars Althof
Submit Date 2004-09-10
Submit Company 57 - Sauer-Danfoss Co.
Revision Number 1
Current Status ISO-Published
Status Date 2005-02-02
Status Comments DDEs have been moved to published for creating the new Annex A
version.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 78/572

DD Entity 134 - Device Element Offset X


Definition X direction offset of a DeviceElement relative to a Device.
Comment The DDI 134, Device element offset X is used to represent the
position offset for any DET element with respect to DRP. Further
details and geometry inheritance can be referenced in ISO11783 part
10.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status Published
Status Date 2021-03-09
Status Comments Comment update

DD Entity 135 - Device Element Offset Y


Definition Y direction offset of a DeviceElement relative to a Device.
Comment The DDI 135, Device element offset Y is used to represent the
position offset for any DET element with respect to DRP. Further
details and geometry inheritance can be referenced in ISO11783 part
10
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 79/572

Unit Symbol mm - Length


Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2021-03-09
Status Comments Comment update

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 80/572

DD Entity 136 - Device Element Offset Z


Definition Z direction offset of a DeviceElement relative to a Device.
Comment The DDI 136, Device element offset Z is used to represent the
position offset for any DET element with respect to DRP. Further
details and geometry inheritance can be referenced in ISO11783 part
10
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol mm - Length
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2021-03-09
Status Comments Comment update.

DD Entity 137 - Device Volume Capacity (Deprecated)


Definition DeviceElement Volume Capacity, dimension of a DeviceElement
Comment This DDE can be used to define the physical volume capacity that
can be filled into this element, like the number of liters that can be
filled into a bin. Note, there are a preferred duplicate DDIs 71, 72 and
73!
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN not specified

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 81/572

CANBus Range 0 - 2147483647


Display Range 0 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2024-02-05
Status Comments Update comment to use lower DDIs

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 82/572

DD Entity 138 - Device Mass Capacity (Deprecated)


Definition DeviceElement Mass Capacity, dimension of a DeviceElement
Comment This DDE can be used to define the weight that can be loaded into
the element. Note, there are a preferred duplicate DDIs 74, 75 and
76!
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol g - Mass large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2024-02-05
Status Comments Update comment to use lower DDIs

DD Entity 139 - Device Count Capacity (Deprecated)


Definition DeviceElement Count Capacity, dimension of a DeviceElement
Comment This DDE can be used to define the count capacity that can be
loaded into the element, like the number of seeds that a grain bin can
carry. Note, there are a preferred duplicate DDIs 77, 78 and 79!
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 83/572

Revision Number 1
Current Status Published
Status Date 2024-02-05
Status Comments Update comment to use lower DDIs

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 84/572

DD Entity 140 - Setpoint Percentage Application Rate


Definition Application Rate expressed as percentage
Comment This DDE defines the setpoint application rate expressed in
percentage. Usually this DDI is used within FMIS systems in
combination with other information like a base-rate or a default-rate.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2023-07-10
Status Comments Comment update

DD Entity 141 - Actual Work State


Definition Actual Work State, 2 bits defined as 00=disabled/off, 01=enabled/on,
10=error, 11=undefined/not installed
Comment See the DDI 290 attachment
"ISO11783-11-DDI-289-SetpointWorkState" as reference for
implementation guideline.

This DDE has been revised in 2012 to be used as the Actual Work
State. A separate Setpoint Work State was added to the data
dictionary at that time.

Original comment: this DDE was a result of March 2005 TF10


meeting.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 85/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN not specified
CANBus Range 0-3
Display Range 0-3
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 86/572

DD Entity 142 - Physical Setpoint Time Latency


Definition The Setpoint Value Latency Time is the time lapse between the
moment of receival of a setpoint value command by the working set
and the moment this setpoint value is physically applied on the
device. That means if the setpoint value is communicated on the
network (CAN bus) but the system needs 2 seconds to adjust the
value physically on the desired unit (device element) then the
Setpoint Latency Time is 2 seconds.
The setpoint time latency value can only be positive.
Comment The use of this DDE is to inform the overall system (e.g. Dektop
Software, Task Controller) how the system works. The TC shall not
shift this information into log files nor shall the device do that when
sending actual values.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol ms - Time
Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

DD Entity 143 - Physical Actual Value Time Latency

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 87/572

Definition The Actual Value Latency Time is the time lapse between the
moment this actual value is communicated to the Task Controller,
and the moment that this actual value is physically applied on the
device. That means if the system needs 2 seconds to calculate or
measure a value before communicating it on the network, then the
Actual Latency Time value is minus 2 seconds.

Depending of the system characteristics the latency time could be


negative or positive.

In case where the system communicates an actual value before the


actual value has been physically applied the latency value should be
positive.

In case where the system communicates an actual value after the


actual value has been physically applied the latency value should be
negative.
Comment The use of this DDE is to inform the overall system (e.g. Dektop
Software, Task Controller) how the system works. The TC shall not
shift this information into log files nor shall the device do that when
sending actual values.

Example for a positive value:

A seed flow sensor is placed at the start of the seed tube. At the
moment the sensor measures seed flow X, it takes Y seconds for this
flow to reach the coulters. The measured value is ahead of the
physical value of the unit (coulters). So the latency could be plus 2
seconds.

Example for a negative value:

A flow sensor has a delay in its response to a flow change that


means it takes Y seconds to realize the change. At the moment the
sensor measures flow X, the flow is already present for Y seconds on
the physical unit. The actual value is ahead of measured value. So
the latency could be minus 2 seconds.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol ms - Time

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 88/572

Resolution 1
SAE SPN not specified
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 89/572

DD Entity 144 - Yaw Angle


Definition Pivot / Yaw Angle of a DeviceElement
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
Unit Symbol ° - Angle
Resolution 0,001
SAE SPN not specified
CANBus Range -180000 - 180000
Display Range -180,000 - 180,000
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2023-07-10
Status Comments Comment "This DDE was a result of March 2005 TF10 meeting."
removed

DD Entity 145 - Roll Angle


Definition Roll Angle of a DeviceElement
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
Unit Symbol ° - Angle
Resolution 0,001
SAE SPN not specified
CANBus Range -180000 - 180000
Display Range -180,000 - 180,000
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 90/572

Submit Company 89 - Kverneland Group, Electronics Division


Revision Number 1
Current Status New Request Submitted
Status Date 2023-07-10
Status Comments Comment "This DDE was a result of March 2005 TF10 meeting."
removed

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 91/572

DD Entity 146 - Pitch Angle


Definition Pitch Angle of a DeviceElement
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
Unit Symbol ° - Angle
Resolution 0,001
SAE SPN not specified
CANBus Range -180000 - 180000
Display Range -180,000 - 180,000
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2023-07-10
Status Comments Comment "This DDE was a result of March 2005 TF10 meeting."
removed

DD Entity 147 - Log Count


Definition Log Counter, may be used to control data log record generation on a
Task Controller
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol n.a. -
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by 11783-Part 10 Task Force
Submit Date 2005-03-01

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 92/572

Submit Company 89 - Kverneland Group, Electronics Division


Revision Number 1
Current Status Published
Status Date 2023-07-10
Status Comments Comment "This DDE was a result of March 2005 TF10 meeting."
removed

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 93/572

DD Entity 148 - Total Fuel Consumption


Definition Accumulated Fuel Consumption as Counter
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Stephan Zelleröhr
Submit Date 2005-04-12
Submit Company 103 - Agrocom GmbH & Co. Agrarsystem KG
Revision Number 1
Current Status ISO-Published
Status Date 2005-05-09
Status Comments DDEs have been moved to published for creating the new Annex A
version.

DD Entity 149 - Instantaneous Fuel Consumption per Time


Definition Fuel consumption per time
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 94/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Stephan Zelleröhr
Submit Date 2005-04-12
Submit Company 103 - Agrocom GmbH & Co. Agrarsystem KG
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added "Instantaneous" for clarification

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 95/572

DD Entity 150 - Instantaneous Fuel Consumption per Area


Definition Fuel consumption per area
Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm³/m² - Capacity per area unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Stephan Zelleröhr
Submit Date 2005-04-12
Submit Company 103 - Agrocom GmbH & Co. Agrarsystem KG
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added "Instantaneous" for clarification.

DD Entity 151 - Instantaneous Area Per Time Capacity


Definition Area per time capacity
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 96/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm²/s - Area per time unit
Resolution 1
SAE SPN not specified
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Stephan Zelleröhr
Submit Date 2005-04-12
Submit Company 103 - Agrocom GmbH & Co. Agrarsystem KG
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added "Instantaneous" for clarification.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 97/572

DD Entity 153 - Actual Normalized Difference Vegetative Index (NDVI)


Definition The Normalized Difference Vegetative Index (NDVI) computed from
crop reflectances as the difference between NIR reflectance in the
780 to 880 nm band and red reflectance in the 640 to 680 nm band
divided by the sum of the NIR and red reflectance in the same bands.
Comment Document attached.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol n.a. -
Resolution 0,001
SAE SPN TBD
CANBus Range -1000 - 1000
Display Range -1,000 - 1,000
Submit by Marvin Stone
Submit Date 2008-04-28
Submit Company 39 - Microfirm Inc.
Revision Number 1
Current Status Published
Status Date 2020-05-04
Status Comments CANBus Range and Display Range change
Attachment 2009-08-11: Definition summary - NDVI_definition_summary.pdf

DD Entity 154 - Physical Object Length


Definition Length of device element (dimension along the X-axis)
Comment The reference point of the device element shall be located in the
center of the device element
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 98/572

CANBus Range 0 - 2147483647


Display Range 0 - 2147483647
Submit by Hans Jürgen Nissen
Submit Date 2008-12-03
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 99/572

DD Entity 155 - Physical Object Width


Definition Width of device element (dimension along the Y-axis)
Comment The reference point of the device element shall be located in the
center of the device element
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hans Jürgen Nissen
Submit Date 2008-12-03
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments

DD Entity 156 - Physical Object Height


Definition Height of device element (dimension along the Z-axis)
Comment The reference point of the device element shall be located in the
center of the device element

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 100/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hans Jürgen Nissen
Submit Date 2008-12-03
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 101/572

DD Entity 157 - Connector Type


Definition Specification of the type of coupler. The value definitions are:
-1 = Not available
0 = unknown (default),
1 = ISO 6489-3 Tractor drawbar,
2 = ISO 730 Three-point-hitch semi-mounted,
3 = ISO 730 Three-point-hitch mounted,
4 = ISO 6489-1 Hitch-hook,
5 = ISO 6489-2 Clevis coupling 40,
6 = ISO 6489-4 Piton type coupling,
7 = ISO 6489-5 CUNA hitch,
8 = ISO 24347 Ball type hitch,
9 = Chassis Mounted - Self-Propelled,
10 = ISO 5692-2 Pivot wagon hitch

All other values are reserved for future assignments.


Comment This DDE allows systems to automatically select the connection
between devices. For instance, when 2 devices are on the network
that declare device elements with the same connector type, the
system can connect them accordingly.
This DDE shall be used with the Device Element of type "Connector"
only.

Other standards for Mechanical connections between towed and


towing vehicles to look at are:
ISO 8755, ISO 21244, ISO 5692-1, ISO 8718, ISO 12357, ISO 3584,
ISO 1102, ISO 11406, ISO 11407, ISO 20019, DIN 74054, DIN
11026, DIN 11043
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -1 - 10

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 102/572

Display Range -1 - 10
Submit by Hans Jürgen Nissen
Submit Date 2008-12-03
Submit Company 33 - John Deere
Revision Number 3
Current Status Published
Status Date 2020-10-05
Status Comments Define Pivot Wagon Hitch as own type number 10.

DD Entity 158 - Prescription Control State


Definition Defines and synchronise the actual state of the prescription system.
The state is represented by the lowest significant 2 bits in the lowest
significant byte of the process data value: Byte 1: bit 0-1: 00 =
manual/off, 01 = auto/on, 10 = error indicator, 11 = undefined/not
installed. bits 2-7: reserved set to 0. Byte 2-4: reserved set to 0.

The DDI shall support the On Change trigger so that the TC is able to
get informed when the value gets changed by the Working Set
Master. The TC shall active this trigger when using the DDI.

See attachment for more information


Comment The prescription control master and its clients need to be
synchronized in terms of their general state or activation by the user
(System activated/deactivated in individual setups). This DDE serves
2 purposes, one is to synchronize the prescription control state and
the other is to enable a TC client to announce the support and initial
state of its prescription control capabilities. Synchronisation by the
prescription master (TC) is done by setting the prescription state of
connected TC clients with a process data set value message with this
DDE. It is recommended that TC clients reply their state immediately
when such a message is received. The property flag "setable" and
the trigger method "on change" shall be used with this DDE. The
state "manual/off" indicates that the device is in manual state and will
ignore all prescription commands. The "auto/on" state indicates that
the client accepts the prescription commands as far as its overall
process state allows.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 103/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Matthias Meyer
Submit Date 2008-11-07
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments
Attachment 2019-01-14: Example Prescription Control State -
ISO11783-11-DDI-158-Prescription Control State-v2.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 104/572

DD Entity 159 - Number of Sub-Units per Section


Definition Specifies the number of Units for a section (e.g. number of nozzles
per sprayer section or number of planter seeding rows common to a
controlled
section).
Comment This DDE is used in a Section Device Element to indicate the number
of physical Units under that section. The Units are of interest to the
operator
but not needed for the Task Controller operation itself. With this
information and the overall width of the section, a Task Controller with
a user
interface may calculate and depict for instance the row spacing
without having individual objects for each row in the DDOP. An
implement should
not include Unit Device Elements under any Section where this DDI
exists. If Unit device elements are defined under a Section element
in the
DDOP and this DDI value is also included in the Section element, this
DDI value shall be ignored.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jason Walter
Submit Date 2008-12-03
Submit Company 33 - John Deere
Revision Number 1
Current Status Published
Status Date 2024-02-14
Status Comments Textual update on the Definition and Comments field only.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 105/572

DD Entity 160 - Section Control State


Definition Specifies the actual state of section control. The value definitions are:
Byte 1 (bitfield)
Bit 0-1:
00 = manual/off,
01 = auto/on,
10 = error indicator,
11 = undefined/not installed.
Bits 2-7: reserved, set to 0.
Bytes 2-4: reserved, set to 0.

The DDI shall support the On Change trigger so that the TC is able to
get informed when the value gets changed by the Working Set
Master. The TC shall active this trigger when using the DDI.

See attachment for more information

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 106/572

Comment In section control systems, the section control master and its clients
need to be synchronized in terms of their general state or activation
by the user (System activated/deactivated in individual setups). This
DDE serves 2 purposes, one is to synchronize the section control
state and the other is to enable a TC client to announce the support
and initial state of its section control capabilities. Synchronisation by
the section control master (TC) is done by setting the section control
state of connected TC clients with a process data set value message
with this DDE. It is recommended that TC clients reply their state
immediately when such a message is received. The property flag
"setable" and the trigger method "on change" should be used with
this DDE. The state "manual/off" indicates that the device is in
manual state and will ignore all control commands for section control.
The "auto/on" state indicates that the client accepts the section
control commands as far as its overall process state allows.

Listed below are 4 example Use Cases for this DDE:

Use case "Start up operation":


1. During a start up the implement shall set the SCS to ‘manual
mode’.

Use case "Auto request from TC":


1. The implement receives an ‘auto’ request from TC.
2. The implement shall check whether all setup conditions are fulfilled
to allow section control.
3. If this check is ok: The implement may respond with ‘auto
mode’ and set its internal SCS client to ‘auto mode’.
4. If this check not ok: The implement shall respond with ‘manual
mode’. The internal state is still in manual mode. The TC may
inform the operator accordingly.

Use case "Manual request from TC":


1. The implement receives a manual request from TC.
2. If the implement is still in ‘auto mode’ the implement shall
set its internal SCS client to ‘manual mode’.

Use case "Loss of requirements for auto mode":


1. The implement internal setup conditions don’t allow for
automatic section control anymore.
2. The implement shall set the internal SCS client to ‘manual
mode’.
3. The implement shall send the SCS to inform the TC accordingly.
On reception of this ‘manual mode’ the TC/Section Control
Master may inform the operator accordingly.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 107/572

Typically used by Device 0 - Non-specific system


Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Matthias Meyer
Submit Date 2008-12-03
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments
Attachment 2023-03-24: - ISO11783-11-DDI-160-Section Control State-v2.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 108/572

DD Entity 161 - Actual Condensed Work State (1-16)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 1 to 16 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See attachment on DDI 290
"ISO11783-11-DDI-290-SetpointCondensedWorkState" for
implementation guideline.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 109/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 162 - Actual Condensed Work State (17-32)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 17 to 32 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 110/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 111/572

DD Entity 163 - Actual Condensed Work State (33-48)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 33 to 48 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 112/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 164 - Actual Condensed Work State (49-64)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 49 to 64 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 113/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 114/572

DD Entity 165 - Actual Condensed Work State (65-80)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 65 to 80 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 115/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 166 - Actual Condensed Work State (81-96)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 81 to 96 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 116/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 117/572

DD Entity 167 - Actual Condensed Work State (97-112)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 97 to 112 into a single actual work state of their
parent device element. The actual condensed work state contains the
child element actual work states, in the driving direction from left to
right, where the leftmost child element actual work state are the 2
lowest significant bits of the Process Data Value. Each child device
elements actual work state is represented by 2 bits and defined as:
00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 =
undefined/not installed. In total 16 child device element actual work
states can be contained in one actual condensed work state of their
parent device element. If less than 16 child device element actual
work states are available, then the unused bits shall be set to value
11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 118/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 168 - Actual Condensed Work State (113-128)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 113 to 128 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 119/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 120/572

DD Entity 169 - Actual Condensed Work State (129-144)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 129 to 144 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, tthen he device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 121/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 170 - Actual Condensed Work State (145-160)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 145 to 160 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 122/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 123/572

DD Entity 171 - Actual Condensed Work State (161-176)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 161 to 176 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 124/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 172 - Actual Condensed Work State (177-192)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 177 to 192 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 125/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 126/572

DD Entity 173 - Actual Condensed Work State (193-208)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 193 to 208 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 127/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 174 - Actual Condensed Work State (209-224)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 209 to 224 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 128/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 129/572

DD Entity 175 - Actual Condensed Work State (225-240)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 225 to 240 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 130/572

Submit Date 2008-01-14


Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

DD Entity 176 - Actual Condensed Work State (241-256)


Definition Combination of the actual work states of individual sections or units
(e.g. nozzles) number 241 to 256 into a single actual work state of
their parent device element. The actual condensed work state
contains the child element actual work states, in the driving direction
from left to right, where the leftmost child element actual work state
are the 2 lowest significant bits of the Process Data Value. Each child
device elements actual work state is represented by 2 bits and
defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator,
11 = undefined/not installed. In total 16 child device element actual
work states can be contained in one actual condensed work state of
their parent device element. If less than 16 child device element
actual work states are available, then the unused bits shall be set to
value 11 (not installed). When the parent device element contains the
Actual Condensed Work State DDE, then the device descriptor shall
not contain the individual actual work state DDEs of the child device
elements.
Comment See the DDI 161 attachment
"ISO11783-11-DDI-289-SetpointWorkState" for implementation
guidelines.

This DDE is used to reduce number of messages. Individual work


state messages for a many-sectioned device can potentially cause
performance issues due to overloading communication. With this
DDE, 16 work states can be sent via a single message, resulting in
less traffic to convey on/off status for an entire device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 131/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Adam Bogenrief
Submit Date 2008-01-14
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Submitted (Pending)
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 132/572

DD Entity 177 - Actual length of cut


Definition Actual length of cut for harvested material, e.g. Forage Harvester or
Tree Harvester.
Comment none.
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Hans Jürgen Nissen
Submit Date 2008-09-22
Submit Company 33 - John Deere
Revision Number 1
Current Status Published
Status Date 2020-04-28
Status Comments Remove of decimal point in CANBus Range

DD Entity 178 - Element Type Instance


Definition This DDI is used to enumerate and identify multiple device elements
(DET) of the same type within one Device Description object pool.
The value of this DDI is independent of the DET number. The
combination of device element type and value of Element Type
Instance ETI represents a unique object inside the device description
object pool and therefore shall exist only once per object pool.
Recommendation: The definition of the device elements should be
made from left to right direction or from front to back direction. When
in a matrix, count left-to-right first, then front-to-back and at last
top-to-bottom. See attachment for more information.
Comment This DDE allows the system to communicate with a device element
object independent of the device element number. The same tank of
a seeder for instance could have various device element numbers
based upon the DDD. The DDD structure may change during setup
the implement. In this case a unique implement tank might has a
different element number as before. Particular if the Task Controller
(TC) use a user interface to display and change data by the operator.
Therefore the TC needs clear or rather unique device element
information. Assign this DDE for instance to a DET of type bin. This
number can be displayed to the operator while it may be printed
physically at the bin. The ETI number range from 0 to 65533 inside
the object pool corresponds to a displayed value from 1 to 65534 on
a user interface or physical device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 133/572

Typically used by Device - Not Assigned


Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 65533
Display Range 0 - 65533
Submit by Matthias Meyer
Submit Date 2010-01-15
Submit Company 33 - John Deere
Revision Number 1
Current Status Published
Status Date 2021-08-11
Status Comments Added latest version of attachment
Attachment 2021-08-11: Example of DDOPs with multiple or mixed products -
Multiple and Single Product Implement Description_20101222-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 134/572

DD Entity 179 - Actual Cultural Practice


Definition This DDI is used to define the current cultural practice which is
performed by an individual device operation. For instance a
planter/seeder could provide a sowing and a fertilizing operation at
the same time.

The cultural practice value definitions are: 0=Unknown, 1=Fertilizing,


2=Sowing and Planting, 3=Crop Protection, 4=Tillage, 5=Baling
(Pressing), 6=Mowing, 7=Wrapping, 8=Harvesting, 9=Forage
Harvesting, 10=Transport, 11=Swathing, 12=Slurry/Manure
Application, 13=Self-Loading Wagon, 14=Tedding, 15=Measuring,
16=Irrigation, 17=Feeding/Mixing, 18=Mulching, 19-255=Reserved for
future Assignment

See attachment for more information and DDI 471 Setpoint Cultural
Practice
Comment Implements as Planter or Seeder which provides more than one
product application need an option to sign the cultural practice that is
performed by each operation. More then ever if the applied products
have the same unit type. As for instance a seeder provides a sowing
and fertilizing operation which have both mass per area as unit
defined. In this case it is not clear to the TC that the second operation
is a fertilizing operation. Particular if the TC owns a user interface to
display these information to the operator. Through this DDE the TC
user interface can display the appropriate information. Adding this
DDI to the device element of type device the main cultural practice of
the device could be defined. For instance a baler will claim on the bus
as forage device class and have set the actual cultural practice as
baling.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 135/572

Display Range 0 - 2147483647


Submit by Matthias Meyer
Submit Date 2010-01-15
Submit Company 33 - John Deere
Revision Number 2
Current Status Published
Status Date 2021-12-01
Status Comments New attachment wand reference information to DDI 471 Setpoint
Cultural Practice
Attachment 2021-12-01: - Multiple and Single Product Implement
Description-v2.pdf

DD Entity 180 - Device Reference Point (DRP) to Ground distance


Definition This DDI is used to specify the distance from the Device Reference
Point (DRP) down to the ground surface. The DRP to Ground DDI
shall be attached only to the Device Element (DET) with element
number zero.
Comment Depending on the application it might be required to know the
distance of a device element down to the ground. All device element
offsets refer to the DRP which is the centre of the device coordinate
system and usually not at the ground surface. For instance the DRP
of a tractor is the centre of the rear axle. In this case the distance
from a GPS receiver (DET of type navigation reference) attached on
the roof of the cab is calculated through sum up the Z-offset of the
DET and the distance of the DRP to ground. The value of the DRP in
this case is equivalent to the radius of the rolling wheel which is
attached on the tractor rear axle.
Typically used by Device
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2010-01-15
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 136/572

DD Entity 181 - Dry Mass Per Area Yield


Definition Actual Dry Mass Per Area Yield. The definition of dry mass is the
mass with a reference moisture specified by DDI 184.
Comment The earlier defined DDI 84 is the mass per area that is measured on
e.g. harvesting equipment as a mass including a possibly unknown
moisture percentage. This DDI 181 is the mass per area yield,
corrected to a reference moisture.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lyle Jensen
Submit Date 2010-01-29
Submit Company 102 - AGCO GmbH & Co
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

DD Entity 182 - Dry Mass Per Time Yield


Definition Actual Dry Mass Per Time Yield. The definition of dry mass is the
mass with a reference moisture specified by DDI 184.
Comment The earlier defined DDI 87 is the mass per time that is measured on
e.g. harvesting equipment as a mass including a possibly unknown
moisture percentage. This DDI 182 is the mass per time yield,
corrected to a reference moisture.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lyle Jensen
Submit Date 2010-01-29
Submit Company 102 - AGCO GmbH & Co
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 137/572

DD Entity 183 - Yield Total Dry Mass


Definition Accumulated Yield specified as dry mass. The definition of dry mass
is the mass with a reference moisture specified by DDI 184.
Comment The earlier defined DDI 90 is considered to be the total mass that is
measured on e.g. harvesting equipment as a mass including a
possibly unknown moisture percentage. This DDI 183 is the yield total
mass, corrected to a reference moisture.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lyle Jensen
Submit Date 2010-01-29
Submit Company 102 - AGCO GmbH & Co
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

DD Entity 184 - Reference Moisture For Dry Mass


Definition Moisture percentage used for the dry mass DDIs 181, 182 and 183.
Comment Example: this definition is similar to the "Standard Payable Moisture"
term used by farmers.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lyle Jensen
Submit Date 2010-01-29
Submit Company 102 - AGCO GmbH & Co
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 138/572

DD Entity 185 - Seed Cotton Mass Per Area Yield


Definition Seed cotton yield as mass per area, not corrected for a possibly
included lint percantage.
Comment This Seed Cotton Mass Per Area Yield is the mass of the raw
harvested cotton product as it is measured on e.g. harvesting
equipment.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

DD Entity 186 - Lint Cotton Mass Per Area Yield


Definition Lint cotton yield as mass per area.
Comment This Lint Cotton Mass Per Area Yield is the mass of the lint after it
has been removed from the seed cotton at a cotton gin. Calculated by
use of the Lint Turnout Percentage.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 139/572

DD Entity 187 - Seed Cotton Mass Per Time Yield


Definition Seed cotton yield as mass per time, not corrected for a possibly
included lint percantage.
Comment This Seed Cotton Mass Per Time Yield is the mass of the raw
harvested cotton product as it is measured on e.g. harvesting
equipment.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

DD Entity 188 - Lint Cotton Mass Per Time Yield


Definition Lint cotton yield as mass per time.
Comment This Lint Cotton Mass Per Time Yield is the mass of the lint after it
has been removed from the seed cotton at a cotton gin. Calculated by
use of the Lint Turnout Percentage.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 140/572

DD Entity 189 - Yield Total Seed Cotton Mass


Definition Accumulated yield specified as seed cotton mass, not corrected for a
possibly included lint percantage.
Comment This Yield Total Seed Cotton Mass is the total mass of the raw
harvested cotton product as it is measured on e.g. harvesting
equipment.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

DD Entity 190 - Yield Total Lint Cotton Mass


Definition Accumulated yield specified as lint cotton mass.
Comment This Yield Total Lint Cotton Mass is the total lint cotton mass, after it
has been removed from the total seed cotton at a cotton gin.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 141/572

DD Entity 191 - Lint Turnout Percentage


Definition Percent of lint in the seed cotton.
Comment
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Andy Beck
Submit Date 2010-02-26
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Approved
Status Date 2010-03-12
Status Comments

DD Entity 192 - Ambient temperature


Definition Ambient temperature measured by a machine. Unit is milli-Kelvin
(mK).
Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Timo Oksanen
Submit Date 2011-01-17
Submit Company Aalto University
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 142/572

Current Status ISO-Approved


Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 143/572

DD Entity 193 - Setpoint Product Pressure


Definition Setpoint Product Pressure to adjust the pressure of the product flow
system at the point of dispensing.
Comment On pressure-based control systems, it is important to be able to
monitor and control the system pressure to ensure the proper flow
rate and droplet size. Being able to display and log pressure is
important. On sprayers, this would be the boom pressure.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-01-19
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-03-27
Status Comments

DD Entity 194 - Actual Product Pressure


Definition Actual Product Pressure is the measured pressure in the product flow
system at the point of dispensing.
Comment On pressure-based control systems, it is important to be able to
monitor and conrol the system pressure to ensure the proper flow
rate and droplet size. Being able to display and log pressure is
important. On sprayers, this would be the boom pressure.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 144/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 145/572

DD Entity 195 - Minimum Product Pressure


Definition Minimun Product Pressure in the product flow system at the point of
dispensing.
Comment Minimum system product pressure to ensure a consistent product
flow.
See also "Setpoint Product Pressure"
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

DD Entity 196 - Maximum Product Pressure


Definition Maximum Product Pressure in the product flow system at the point of
dispensing.
Comment Maximum system product to ensure a stable and safe product flow.
See also "Setpoint Product Pressure"

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 146/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 147/572

DD Entity 197 - Setpoint Pump Output Pressure


Definition Setpoint Pump Output Pressure to adjust the pressure at the output
of the solution pump.
Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-01-19
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-03-27
Status Comments

DD Entity 198 - Actual Pump Output Pressure


Definition Actual Pump Output Pressure measured at the output of the solution
pump.
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 148/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 149/572

DD Entity 199 - Minimum Pump Output Pressure


Definition Minimum Pump Output Pressure for the output pressure of the
solution pump.
Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

DD Entity 200 - Maximum Pump Output Pressure


Definition Maximum Pump Output Pressure for the output pressure of the
solution pump.
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 150/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 151/572

DD Entity 201 - Setpoint Tank Agitation Pressure


Definition Setpoint Tank Agitation Pressure to adjust the pressure for a stir
system in a tank.
Comment In a liquid application system, this is the pressure used to stir the tank
contents to prevent products in liquid suspension from settling in the
tank.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-01-19
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-03-27
Status Comments

DD Entity 202 - Actual Tank Agitation Pressure


Definition Actual Tank Agitation Pressure measured by the tank stir system.
Comment In a liquid application system, this is the pressure used to stir the tank
contents to prevent products in liquid suspension from settling in the
tank. Typically measured at the agitation manifold.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 152/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 153/572

DD Entity 203 - Minimum Tank Agitation Pressure


Definition Minimun Tank Agitation Pressure for a stir system in a tank.
Comment Minimum tank agitation pressure to prevent products in liquid
suspension from settling in the tank.
See also "Setpoint Tank Agitation Pressure".
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

DD Entity 204 - Maximum Tank Agitation Pressure


Definition Maximun Tank Agitation Pressure for a stir system in a tank.
Comment Maximum tank agitation pressure to prevent products in liquid
suspension from settling in the tank.
See also "Setpoint Tank Agitation Pressure"

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 154/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748364,8 - 214748364,7
Submit by Tony Woodcock
Submit Date 2011-03-09
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-05
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 155/572

DD Entity 205 - SC Setpoint Turn On Time


Definition The Section Control Turn On Time defines the overall time lapse
between the moment the TC sends a turn on section command to the
working set and the moment this section is physically turned on and
the product is applied.
The working set may support this DDE as an optional feature to
provide the possibility to store the time settings direct on the device to
make the settings available after a power cycle. Therefore this DDE
needs always to be setable by the TC and shall not be used to
change any working set system behavior.

The DDI shall support the On Change trigger so that the TC is able to
get informed when the value gets changed by the Working Set
Master. The TC shall active this trigger when using the DDI.
Comment The SC Turn On Time setting is used to compensate the average
physical machine reaction time (Electrical & Mechanical) from the
moment the Task Controller send the command and the Working Set
applies the product.
To find the right time setting for the used system combination of Task
Controller and Working Set it could take awhile and therefore it is a
big benefit to store the setting on the working set to make them again
available after a power cycle. For working sets supporting Section
Control it is recommended to add SC Turn On Time to its device
description and make it setable.
In case where the device description contains also Physical Setpoint
Time Latency or Physical Actual Time Latency the TC Turn On Time
will always supercede it. See also attachment and DDI 206, 656 and
657.
Typically used by Device 0 - Non-specific system
Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbol ms - Time
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-03-09
Submit Company John Deere
Revision Number 2
Current Status Published
Status Date 2022-01-10
Status Comments Renamed from SC Tirn On Time to SC Setpoint Turn On Tim and
added attachment
Attachment 2022-01-10: - ISO11783-11-DDI-205-SC Actual Turn On-Off
Time-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 156/572

DD Entity 206 - SC Setpoint Turn Off Time


Definition The Section Control Turn Off Time defines the overall time lapse
between the moment the TC sends a turn off section command to the
working set and the moment this section is physically turned off.
The working set may support this DDE as an optional feature to
provide the possibility to store the time settings direct on the device to
make the settings available after a power cycle. Therefore this DDE
needs always to be setable by the TC and shall not be used to
change any working set system behavior.

The DDI shall support the On Change trigger so that the TC is able to
get informed when the value gets changed by the Working Set
Master. The TC shall active this trigger when using the DDI.
Comment The SC Turn Off Time setting is used to compensate the average
physical machine reaction time (Electrical & Mechanical) from the
moment the Task Controller send the command and the Working Set
turns off the sections.
To find the right time setting for the used system combination of Task
Controller and Working Set it could take awhile and therefore it is a
big benefit to store the setting on the Working Set to make them
again available after a power cycle. For Working Sets supporting
Section Control it is recommended to add SC Turn Off Time to its
device description and make it setable. See also DDI 205 including
attachment and DDI 656 and 657
Typically used by Device 0 - Non-specific system
Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbol ms - Time
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-03-09
Submit Company John Deere
Revision Number 2
Current Status Published
Status Date 2022-01-10
Status Comments Renamed to SC Setpoint Turn Off Time; Comment Update

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 157/572

DD Entity 207 - Wind speed


Definition Wind speed measured in the treated field at the beginning of
operations or on the application implement during operations.
Measurements at to be made at 2m height or 1 m over the canopy in
tree and bush crops.
On implements the wind speed needs to be compansated by
implement true ground speed and heading.
Comment Requested by TC23 SC6 WG15
Typically used by Device 1 - Tractor
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
14 - Special Crops
17 - Sensor System
Unit Symbol mm/s - Speed
Resolution 1
SAE SPN
CANBus Range 0 - 100000000
Display Range 0 - 100000000
Submit by Bob Benneweis
Submit Date 2011-03-16
Submit Company Benneweis Consulting Ltd
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

DD Entity 208 - Wind direction


Definition Wind direction measured in the treated field at the beginning of
operations or on the application implement during operations.
Measurements at to be made at 2m height or 1 m over the canopy in
tree and bush crops.
On implements the wind direction needs to be compansated by
implement true ground speed and heading.
Comment
Typically used by Device 1 - Tractor
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
14 - Special Crops
17 - Sensor System
Unit Symbol ° - Angle
Resolution 1
SAE SPN
CANBus Range 0 - 359
Display Range 0 - 359
Submit by Bob Benneweis

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 158/572

Submit Date 2011-03-16


Submit Company Benneweis Consulting Ltd
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 159/572

DD Entity 209 - Relative Humidity


Definition Ambient humidty measured by a weather station in a treated field or
on the application implement.
Comment
Typically used by Device 1 - Tractor
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
14 - Special Crops
17 - Sensor System
Unit Symbol % - Percent
Resolution 1
SAE SPN
CANBus Range 0 - 100
Display Range 0 - 100
Submit by Bob Benneweis
Submit Date 2011-03-16
Submit Company Benneweis Consulting Ltd
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-04
Status Comments

DD Entity 210 - Sky conditions


Definition This DDE is used to define the current sky conditions during
operation. The METAR format and its abbrivations is used as follows
to define the sky conditions:

CLR=Clear, NSC=Mostly Sunny, FEW=Partly Sunny, SCT=Partly


cloud, BKN=Mostly cloudy, OVC=overcast/cloudy

1. Byte = first character


2. Byte = second character
3. Byte = third character
4. Byte = fourt character

Unused bytes shall be set to 0x20


Byte 1 to 4 set to 0x00 = error
Byte 1 to 4 set to 0xFF = not available

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 160/572

Comment To setup the METAR abbrivations the IS0 8859-1 standard is used.
From the Latin-1 printable characters set the capitals from "A" (0x41)
to "Z" (0x5A ) shall be used. The space "SP" (0x20) is used for
unused bytes.

Example for Clear (CLR):


1. Byte = 0x43(C)
2. Byte = 0x4C(L)
3. Byte = 0x52 (R)
4. Byte = 0x20 (unused)
Typically used by Device 1 - Tractor
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
9 - Forage harvester
10 - Irrigation
14 - Special Crops
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Bob Benneweis
Submit Date 2011-03-16
Submit Company Benneweis Consulting Ltd
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-29
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 161/572

DD Entity 211 - Last Bale Flakes per Bale


Definition The number of flakes in the most recently produced bale.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler can add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 1000
Display Range 0 - 1000
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

DD Entity 212 - Last Bale Average Moisture


Definition The average moisture in the most recently produced bale.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 100000000
Display Range 0 - 100000000
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 162/572

DD Entity 213 - Last Bale Average Strokes per Flake


Definition The number of baler plunger compression strokes per flake that has
entered the bale compression chamber. This value is the average
valid for the most recently produced bale.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 1000
Display Range 0 - 1000
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

DD Entity 214 - Lifetime Bale Count


Definition The number of bales produced by a machine over its entire lifetime.
This DDE value can not be set through the process data interface but
can be requested and added to a datalog. This DDE value is not
affected by a task based total bales but will increment at the same
rate as the task based total.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 163/572

Current Status Published


Status Date 2024-02-05
Status Comments Add attachment
Attachment 2024-02-05: - ISO11783-11-DD-214-Bale Documentation-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 164/572

DD Entity 215 - Lifetime Working Hours


Definition The number of working hours of a device element over its entire
lifetime. This DDE value can not be set through the process data
interface but can be requested and added to a datalog.
Comment The recommended use of this DDE is to be transmitted on a request
basis only.

The Lifetime Working Hours is the overall time when the device was
turned on.

This total does not refer to an application controlled by a Task


Controller. Therefore this DDE shall not be setable within the device
description and neither shall the device reset the value when the task
status changed. It is up to the device control system when to reset
this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.

Note: unit is h and the bit resolution is 0.05 h/bit, this aligns the
resolution and range with similar SPNs as defined in SAE J1939-71.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol h - Hour
Resolution 0,05
SAE SPN
CANBus Range 0 - 4211081215
Display Range 0,00 - 210554060,75
Submit by Jaap van Bergeijk
Submit Date 2011-04-30

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 165/572

Submit Company AGCO


Revision Number 1
Current Status Published
Status Date 2020-05-04
Status Comments CANBus Range and Display Range correction

DD Entity 216 - Actual Bale Hydraulic Pressure


Definition The actual value of the hydraulic pressure applied to the sides of the
bale in the bale compression chamber.
Comment The actual pressure is the resultant of the baler controller targeting a
certain setpoint plunger load.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 166/572

DD Entity 217 - Last Bale Average Hydraulic Pressure


Definition The average actual value of the hydraulic pressure applied to the
sides of the bale in the bale compression chamber. This average is
calculated over the most recently produced bale.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

DD Entity 218 - Setpoint Bale Compression Plunger Load


Definition The setpoint bale compression plunger load expressed as
percentage
Comment This value is measured / controlled for each new flake that entered
the baler chamber and obtained at the rear dead end of the plunger.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 167/572

DD Entity 219 - Actual Bale Compression Plunger Load


Definition The actual bale compression plunger load expressed as percentage.
Comment This is the plunger load measured at the rear dead end of the plunger
cycle and only updated for each new flake that has entered the baler
chamber.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 2
Current Status Published
Status Date 2018-02-26
Status Comments There was an industry request to change the unit to ppm.

DD Entity 220 - Last Bale Average Bale Compression Plunger Load


Definition The average bale compression plunger load for the most recently
produced bale expressed as percentage.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 168/572

DD Entity 221 - Last Bale Applied Preservative


Definition The total preservative applied to the most recently produced bale.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

DD Entity 222 - Last Bale Tag Number


Definition The Last Bale Tag Number as a decimal number in the range of 0 to
2147483647. Note that the value of this DDI has the limitation of
being an signed 32 bit number.
Comment For balers: the recommended use of this DDE is for a baler to report
this once for every bale that is produced. A baler may add this to its
default set of data, based on an internal on-change data trigger that
causes the baler to report the value of this DDE after the bale is
produced. The recommendation for data logging is that all "Last Bale"
DDEs that are supported by a device are reported together at the
moment that the bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status Published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 169/572

Status Date 2024-03-05


Status Comments Change of value range to signed integer format

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 170/572

DD Entity 223 - Last Bale Mass


Definition The mass of the bale that has most recently been produced.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-04-30
Submit Company AGCO
Revision Number 1
Current Status ISO-Approved
Status Date 2011-04-30
Status Comments

DD Entity 224 - Delta T


Definition The difference between dry bulb temperature and wet bulb
temperature measured by a weather station in a treated field or on
the application equipment.
Comment This parameter is used to determine spray effectiveness in hot and
dry environments. If the Delta T value is too high the effectiveness of
the overall spray application does not match the requirement for this
operation. This value can be used by the application to notify the
operator about the effectiveness and whether he should continue with
the application or not. It can also be used to document the application
environment within the log files for the task.
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
7 - Harvesters
9 - Forage harvester
17 - Sensor System
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Meyer
Submit Date 2011-05-25

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 171/572

Submit Company John Deere


Revision Number 1
Current Status ISO-Approved
Status Date 2011-06-20
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 172/572

DD Entity 225 - Setpoint Working Length


Definition Setpoint Working Length of Device Element.
Comment This is the desired working length of the device element during
operation. For the geometry definition and example use, see the
attachment of the Actual Working Length, DDI 226.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Moritz Roeingh
Submit Date 2011-07-12
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2011-08-31
Status Comments

DD Entity 226 - Actual Working Length


Definition Actual Working Length of a Device Element.
Comment Used for Section Control. By using the Actual Working Length of a
device element a rectangular area is defined. This area represents
the current working area and defines offsets for turning sections on
and off by Section Control. The Actual Working Length parameter is
useful for fertilizer spreaders and similar implements.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 173/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Moritz Roeingh
Submit Date 2011-07-07
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2011-08-31
Status Comments
Attachment 2012-07-03: - ISO11783-11-DDI-226-ActualWorkingLength-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 174/572

DD Entity 227 - Minimum Working Length


Definition Minimum Working Length of Device Element.
Comment This is the minimum working length of the device element during
operation. For the geometry definition and example use, see the
attachment of the Actual Working Length, DDI 226.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Moritz Roeingh
Submit Date 2011-07-12
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2011-08-31
Status Comments

DD Entity 228 - Maximum Working Length


Definition Maximum Working Length of Device Element.
Comment This is the maximum working length of the device element during
operation. For the geometry definition and example use, see the
attachment of the Actual Working Length, DDI 226.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 175/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Moritz Roeingh
Submit Date 2011-07-12
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2011-08-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 176/572

DD Entity 229 - Actual Net Weight


Definition Actual Net Weight value specified as mass
Comment The Actual Net Weight is the current measured mass by a weighing
system.
For more information see attachment located at Actual Net Weight
DDE
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments
Attachment 2011-09-28: - ISO11783-11-DDI-229-Weighing System
Implementation.pdf

DD Entity 230 - Net Weight State


Definition Net Weight State, 2 bits defined as:
00 = unstable measurement
01 = stable measurement
10 = error (measuring error)
Comment The Net Weight State indicates whether the current Actual Net
Weight value is a reliable value or not.
Example: After a mass of grain is filled into a grain cart it takes a
while until the weighing system is able to provide the valid value of
the load.
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 177/572

DD Entity 231 - Setpoint Net Weight


Definition Setpoint Net Weight value.
Comment The Setpoint Net Weight value is used to prompt the weighing system
to perform a tare procedure. For more information see attachment
located at Actual Net Weight DDE.
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments

DD Entity 232 - Actual Gross Weight


Definition Actual Gross Weight value specified as mass
Comment The Actual Gross Weight is the overall measured mass by a weighing
system. For more information see attachment located at Actual Net
Weight DDE.
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 178/572

DD Entity 233 - Gross Weight State


Definition Gross Weight State, 2 bits defined as:
00 = unstable measurement
01 = stable measurement
10 = error (measuring error)
Comment The Gross Weight State indicates whether the current Actual Gross
Weight value is a reliable value or not. For more information see
attachment located at Actual Net Weight DDE.

Example: After a mass of grain is filled into a grain cart it takes a


while until the weighing system is able to provide the valid value of
the load.
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments

DD Entity 234 - Minimum Gross Weight


Definition Minimum Gross Weight specified as mass.
Comment The Minimum Gross Weight may represent the minimum value of the
effective range of the weighing system. For more information see
attachment located at Actual Net Weight DDE.
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 179/572

DD Entity 235 - Maximum Gross Weight


Definition Maximum Gross Weight specified as mass.
Comment Maximum Gross Weight may represent the maximum value of the
effective range of the weighing system. For more information see
attachment located at Actual Net Weight DDE.
Typically used by Device 11 - Transport / Trailers
Class(es) 17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2011-09-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2011-09-28
Status Comments

DD Entity 236 - Thresher Engagement Total Time


Definition Accumulated time while the threshing mechanism is engaged
Comment This DDE represents the total engagement time of the threshing
mechanism of the machine and is recommended to be used at
maximum once within the device description in the device element
that represents the machine.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 180/572

DD Entity 237 - Actual Header Working Height Status


Definition Actual status of the header being above or below the threshold height
for the in-work state.
2 bit status indicator:
00=disabled/off/above threshold height
01=enabled/on/below threshold height
10=error
11=undefined/not installed
Comment The DDE has been defined to be able to communicate a more
detailed work state of a machine.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-11-17
Status Comments

DD Entity 238 - Actual Header Rotational Speed Status


Definition Actual status of the header rotational speed being above or below the
threshold for in-work state.
2 bit status indicator:
00=disabled/off/below threshold speed
01=enabled/on/above threshold speed
10=error
11=undefined/not installed
Comment The DDE has been defined to be able to communicate a more
detailed work state of a machine.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Robert Waggoner

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 181/572

Submit Date 2011-07-08


Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 182/572

DD Entity 239 - Yield Hold Status


Definition Status indicator for the yield measurement system. When enabled/on,
the measurements from the yield measurement system are ignored
and the yield is held constant.
2 bit status indicator:
00=disabled/off
01=enabled/on
10=error
11=undefined/not installed
Comment This status indicator can e.g. be set by the operator when entering an
area of the field where the yield measurement system yield
measurements should not be used.
This DDE shall not be setable by the TC.
The values of the following list of DDE's is are held constant when
this DDE is enabled/on: DDI's 83 to 91, 181 to 183 and 185 to 190.
Typically used by Device 6 - Sprayers
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 240 - Actual (Un)Loading System Status

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 183/572

Definition Actual status of the Unloading and/or Loading system. This DDE
covers both Unloading and Loading of the device element wherein it
is listed. Bits that are not mentioned are reserved and shall be set to
1.
Byte 1:
2 bit unloading status indicator, bit 1 and 2:
00=disabled/off
01=enabled/on/unloading
10=error
11=undefined/not installed
Byte 2:
2 bit loading status indicator, bit 1 and 2:
00=disabled/off
01=enabled/on/loading
10=error
11=undefined/not installed
Byte 3: set to FF
Byte 4: set to FF
Comment Note: The bits of a byte are defined from 1 to 8 (87654321)
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 2
Current Status New Request Submitted
Status Date 2020-04-23
Status Comments added that byte 3 and 4 shall be set to FF; The value that is
transferred over the canbus can be negative

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 184/572

DD Entity 241 - Crop Temperature


Definition Temperature of harvested crop
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 242 - Setpoint Sieve Clearance


Definition Setpoint separation distance between Sieve elements
Comment
Typically used by Device 6 - Sprayers
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 185/572

DD Entity 243 - Actual Sieve Clearance


Definition Actual separation distance between Sieve elements
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 244 - Minimum Sieve Clearance


Definition Minimal separation distance between Sieve elements
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 186/572

DD Entity 245 - Maximum Sieve Clearance


Definition Maximum separation distance between Sieve elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 246 - Setpoint Chaffer Clearance


Definition Setpoint separation distance between Chaffer elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 187/572

DD Entity 247 - Actual Chaffer Clearance


Definition Actual separation distance between Chaffer elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 3
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 248 - Minimum Chaffer Clearance


Definition Minimum separation distance between Chaffer elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 188/572

DD Entity 249 - Maximum Chaffer Clearance


Definition Maximum separation distance between Chaffer elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 250 - Setpoint Concave Clearance


Definition Setpoint separation distance between Concave elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 189/572

DD Entity 251 - Actual Concave Clearance


Definition Actual separation distance between Concave elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 3
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 252 - Minimum Concave Clearance


Definition Minimum separation distance between Concave elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 190/572

DD Entity 253 - Maximum Concave Clearance


Definition Maximum separation distance between Concave elements.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 254 - Setpoint Separation Fan Rotational Speed


Definition Setpoint rotational speed of the fan used for separating product
material from non product material.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 191/572

DD Entity 255 - Actual Separation Fan Rotational Speed


Definition Actual rotational speed of the fan used for separating product
material from non product material.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 3
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 256 - Minimum Separation Fan Rotational Speed


Definition Minimum rotational speed of the fan used for separating product
material from non product material.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 192/572

DD Entity 257 - Maximum Separation Fan Rotational Speed


Definition Maximum rotational speed of the fan used for separating product
material from non product material.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Jaap van Bergeijk
Submit Date 2011-10-17
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 258 - Hydraulic Oil Temperature


Definition Temperature of fluid in the hydraulic system.
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 2000000
Display Range 0 - 2000000
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 193/572

Revision Number 3
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 194/572

DD Entity 259 - Yield Lag Ignore Time


Definition Amount of time to ignore yield data, starting at the transition from the
in-work to the out-of-work state. During this time, the yield sensor
provides inconsistent or unreliable crop flow data.
Comment This DDE can be used to filter the yield data when creating yield
maps. The values of the following list of DDE's may be inconsistent or
unreliable during this yield lag ignore time: DDI's 83 to 91, 181 to 183
and 185 to 190.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ms - Time
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 3
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

DD Entity 260 - Yield Lead Ignore Time


Definition Amount of time to ignore yield data, starting at the transition from the
out-of-work to the in-work state. During this time, the yield sensor
provides inconsistent or unreliable crop flow data.
Comment This DDE can be used to filter the yield data when creating yield
maps. The values of the following list of DDE's may be inconsistent or
unreliable during this yield lead ignore time: DDI's 83 to 91, 181 to
183 and 185 to 190.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ms - Time
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 3
Current Status ISO-Published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 195/572

Status Date 2011-10-17


Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 196/572

DD Entity 261 - Average Yield Mass Per Time


Definition Average Yield expressed as mass per unit time, not corrected for the
reference moisture percentage DDI 184. This value is the average for
a Task and may be reported as a total.
Comment This Average Yield Mass Per Time is the mass that includes the
average crop moisture (DDI 262) if this is measured on e.g.
harvesting equipment. This average yield mass per time is calculated
as the yield total mass (DDI 90) divided by the effective total time
(DDI 119) of the active task.
When a task is resumed and its previously recorded totals are sent by
the task controller to the connected working set, a situation can occur
where there is a discrepancy between the yield total mass, the
effective total time and the average yield mass per time values. In
case all three of these DDI's are present in the device description and
all three values are set by the task controller upon resuming a task,
the working set shall compute its average yield mass per time from
the yield total mass divided by the effective total time and shall
discard the average yield mass per time value that it received from
the task controller.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 2
Current Status ISO-Approved
Status Date 2011-10-17
Status Comments

DD Entity 262 - Average Crop Moisture


Definition Average Moisture of the harvested crop. This value is the average for
a Task and may be reported as a total.
Comment This is the average of the actual crop moisture (DDI 99) for the active
task and is calculated as an average based upon the yield total mass
(DDI 90). In order to correctly calculate this value when a task is
resumed, the yield total mass shall also be reported by the device as
a total. When a task is resumed, the task controller sets both the yield
total mass and the average crop moisture values. The device uses
these values to derive the total moisture and calculate and report the
new average crop moisture values for the resumed task.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 197/572

Typically used by Device 7 - Harvesters


Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 3
Current Status ISO-Published
Status Date 2011-10-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 198/572

DD Entity 263 - Average Yield Mass Per Area


Definition Average Yield expressed as mass per unit area, not corrected for the
reference moisture percentage DDI 184. This value is the average for
a Task and may be reported as a total.
Comment This Average Yield Mass Per Area is the mass that includes the
average crop moisture (DDI 262) if this is measured on e.g.
harvesting equipment. This average yield mass per area is
calculated as the yield total mass (DDI 90) divided by the total area
(DDI 116) of the active task.
When a task is resumed and its previously recorded totals are sent by
the task controller to the connected working set, a situation can occur
where there is a discrepancy between the yield total mass, the total
area and the average yield mass per area values. In case all three of
these DDI's are present in the device description and all three values
are set by the task controller upon resuming a task, the working set
shall compute its average yield mass per area from the yield total
mass divided by the total area and shall discard the average yield
mass per area value that it received from the task controller.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Robert Waggoner
Submit Date 2011-07-08
Submit Company AGCO
Revision Number 2
Current Status ISO-Submitted (Pending)
Status Date 2011-10-17
Status Comments

DD Entity 264 - Connector Pivot X-Offset


Definition X direction offset of a connector pivot point relative to DRP.
This DDE shall be only attached to a DET element of type connector.
Comment Some connector types are equipped with a pivot point which will
influence the accuracy of applications as section control, prescription
or sequence control. The Pivot X-Offset is used to define the distance
from the device DRP to the connector pivot point in X direction.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 199/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-03-07
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments
Attachment 2012-03-07: - ISO11783-11-DDI-264-Connector Pivot
X-Offset-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 200/572

DD Entity 265 - Remaining Area


Definition Remaining Area of a field, which is calculated from the total area and
the processed area.
Comment See DDI attachment for further details.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
17 - Sensor System
Unit Symbol m² - Area
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Markus Eikler
Submit Date 2011-12-15
Submit Company Mueller Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments
Attachment 2012-04-02: - ISO11783-11-DDI-265-Remaining Area-v1.pdf

DD Entity 266 - Lifetime Application Total Mass


Definition Entire Application Total Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 201/572

Typically used by Device 4 - Planters /Seeders


Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 202/572

DD Entity 267 - Lifetime Application Total Count


Definition Entire Application Total Count of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 268 - Lifetime Yield Total Volume


Definition Entire Yield Total Volume of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol L - Quantity per volume

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 203/572

Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 204/572

DD Entity 269 - Lifetime Yield Total Mass


Definition Entire Yield Total Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 270 - Lifetime Yield Total Count


Definition Entire Yield Total Count of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 205/572

Unit Symbol # - Quantity/Count


Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 206/572

DD Entity 271 - Lifetime Total Area


Definition Entire Total Area of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
15 - Municipal Work
Unit Symbol m² - Area
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 272 - Lifetime Effective Total Distance


Definition Entire Total Distance of the device lifetime in working position.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 207/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol m - Distance
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-03-09
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 208/572

DD Entity 273 - Lifetime Ineffective Total Distance


Definition Entire Ineffective Total Distance of the device lifetime out of working
position.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol m - Distance
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-03-09
Status Comments

DD Entity 274 - Lifetime Effective Total Time


Definition Entire Effective Total Time of the device lifetime.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 209/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 210/572

DD Entity 275 - Lifetime Ineffective Total Time


Definition Entire Ineffective Total Time of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 276 - Lifetime Fuel Consumption


Definition Entire Fuel Consumption of the device lifetime.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 211/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol L - Capacity count
Resolution 0,5
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 1073741823,5
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 212/572

DD Entity 277 - Lifetime Average Fuel Consumption per Time


Definition Entire Average Fuel Consumption per Time of the device lifetime.
Comment This is the overall average of the device. This average does not refer
to an application controlled by a Task Controller. Therefore this DDE
shall not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by
Submit Date 2012-01-09
Submit Company
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 278 - Lifetime Average Fuel Consumption per Area


Definition Entire Average Fuel Consumption per Area of the device lifetime.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 213/572

Comment This is the overall average of the device. This average does not refer
to an application controlled by a Task Controller. Therefore this DDE
shall not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol mm³/m² - Capacity per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 214/572

DD Entity 279 - Lifetime Yield Total Dry Mass


Definition Entire Yield Total Dry Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 280 - Lifetime Yield Total Seed Cotton Mass


Definition Entire Yield Total Seed Cotton Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol kg - Mass
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 215/572

SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 216/572

DD Entity 281 - Lifetime Yield Total Lint Cotton Mass


Definition Entire Yield Total Lint Cotton Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 14 - Special Crops
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 282 - Lifetime Threshing Engagement Total Time


Definition Entire Threshing Engagement Total Time of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol s - Time count
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 217/572

SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-09
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 218/572

DD Entity 283 - Precut Total Count


Definition The total number of pre-cutted product units produced by a device
during an operation.
Comment Precut Total Count is a total of a device element. It is intended to be
used as a task based total value and therefore it is recommended to
support the on-time and on-change trigger methods. The total trigger
method and the setable property are required for this DDE.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-12
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 284 - Uncut Total Count


Definition The total number of un-cutted product units produced by a device
during an operation.
Comment Uncut Total Count is a total of a device element. It is intended to be
used as a task based total value and therefore it is recommended to
support the on-time and on-change trigger methods. The total trigger
method and the setable property are required for this DDE.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-12
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 219/572

DD Entity 285 - Lifetime Precut Total Count


Definition Entire Precut Total Count of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-01-12
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

DD Entity 286 - Lifetime Uncut Total Count


Definition Entire Uncut Total Count of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 220/572

Display Range 0 - 2147483647


Submit by Matthias Meyer
Submit Date 2012-01-12
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-02-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 221/572

DD Entity 287 - Setpoint Prescription Mode


Definition This DDE defines the source of the Task Controller set point value
sent to the Control Function. This DDI shall be defined as DPD in the
DDOP and needs to be setable. The TC shall then set this DDI before
starting a prescription operation. The WS (Working Set) shall set this
value to zero (0) after system start.
Comment The Task Controller Prescription Mode shall have the following
values:
0 = Unknown / not defined
1 = Prescription Rate
2 = Prescription Default
3 = Prescription GPS loss
4 = Prescription Out Of Field
5 = Manual Entry
6 = Peer Control
7 and higher are reserved for future assignments
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-6
Display Range 0-6
Submit by Joe Tevis
Submit Date 2013-09-23
Submit Company Topcon
Revision Number 2
Current Status Published
Status Date 2022-10-28
Status Comments Change status to published
Attachment 2013-09-23: Prescription Mode and Control Function Mode Use
Cases - Prescription Mode Supporting Doc-v1.ppt

DD Entity 288 - Actual Prescription Mode


Definition This DDE defines the actual source of the set point value used by the
Control Function. This DDI shall be defined as DPD in the DDOP and
shall not be setable and need to support the on change trigger. The
TC should request this DDI in case of an active prescription operation
for documentation purpose.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 222/572

Comment The Control Function Prescription Mode sahll have one of the
following values:
0 = Unknown / not defined
1 = TC rate
2 = Manual Entry
3 = Peer Control
4 = Max override
5 = Min override
6 and higher are reserved for future assignments
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-5
Display Range 0-5
Submit by Joe Tevis
Submit Date 2013-09-23
Submit Company Topcon
Revision Number 2
Current Status Published
Status Date 2022-10-28
Status Comments Change status to published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 223/572

DD Entity 289 - Setpoint Work State


Definition The Setpoint Work State DDI is the control command counterparts to
the Work State DDI (141). The separation of the control commands
through one DDI from the actual state communicated through another
DDI enables verification of the transmission of the control commands
independent from the effectuation of the requested control action.
Comment See DDI 290 attachment for implementation guideline.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments Status was published

DD Entity 290 - Setpoint Condensed Work State (1-16)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 224/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 1 to 16 into a single setpoint
work state of their parent device element. The setpoint condensed
work state contains the child element setpoint work states, in the
driving direction from left to right, where the leftmost child element
setpoint work state are the 2 lowest significant bits of the Process
Data Value. Each child device elements setpoint work state is
represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments
Attachment 2016-04-05: - ISO11783-11-DDI-290-SetpointWorkState-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 225/572

DD Entity 291 - Setpoint Condensed Work State (17-32)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 17 to 32 into a single setpoint
work state of their parent device element. The setpoint condensed
work state contains the child element setpoint work states, in the
driving direction from left to right, where the leftmost child element
setpoint work state are the 2 lowest significant bits of the Process
Data Value. Each child device elements setpoint work state is
represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

DD Entity 292 - Setpoint Condensed Work State (33-48)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 226/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 33 to 48 into a single setpoint
work state of their parent device element. The setpoint condensed
work state contains the child element setpoint work states, in the
driving direction from left to right, where the leftmost child element
setpoint work state are the 2 lowest significant bits of the Process
Data Value. Each child device elements setpoint work state is
represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 227/572

DD Entity 293 - Setpoint Condensed Work State (49-64)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 49 to 64 into a single setpoint
work state of their parent device element. The setpoint condensed
work state contains the child element setpoint work states, in the
driving direction from left to right, where the leftmost child element
setpoint work state are the 2 lowest significant bits of the Process
Data Value. Each child device elements setpoint work state is
represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

DD Entity 294 - Setpoint Condensed Work State (65-80)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 228/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 65 to 80 into a single setpoint
work state of their parent device element. The setpoint condensed
work state contains the child element setpoint work states, in the
driving direction from left to right, where the leftmost child element
setpoint work state are the 2 lowest significant bits of the Process
Data Value. Each child device elements setpoint work state is
represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 229/572

DD Entity 295 - Setpoint Condensed Work State (81-96)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 81 to 96 into a single setpoint
work state of their parent device element. The setpoint condensed
work state contains the child element setpoint work states, in the
driving direction from left to right, where the leftmost child element
setpoint work state are the 2 lowest significant bits of the Process
Data Value. Each child device elements setpoint work state is
represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

DD Entity 296 - Setpoint Condensed Work State (97-112)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 230/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 97 to 112 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 231/572

DD Entity 297 - Setpoint Condensed Work State (113-128)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 113 to 128 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 2
Current Status ISO-Published
Status Date 2016-06-27
Status Comments

DD Entity 298 - Setpoint Condensed Work State (129-144)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 232/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 129 to 144 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 233/572

DD Entity 299 - Setpoint Condensed Work State (145-160)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 145 to 160 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

DD Entity 300 - Setpoint Condensed Work State (161-176)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 234/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 161 to 176 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 235/572

DD Entity 301 - Setpoint Condensed Work State (177-192)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 177 to 192 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

DD Entity 302 - Setpoint Condensed Work State (193-208)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 236/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 193 to 208 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 237/572

DD Entity 303 - Setpoint Condensed Work State (209-224)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 209 to 224 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

DD Entity 304 - Setpoint Condensed Work State (225-240)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 238/572

Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 225 to 240 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.
Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 239/572

DD Entity 305 - Setpoint Condensed Work State (241-256)


Definition The Setpoint Condensed Work State DDIs are the control command
counterparts to the Condensed Work States DDIs (161 – 176).

The value is a combination of the setpoint work states of individual


sections or units (e.g. nozzles) number 241 to 256 into a single
setpoint work state of their parent device element. The setpoint
condensed work state contains the child element setpoint work
states, in the driving direction from left to right, where the leftmost
child element setpoint work state are the 2 lowest significant bits of
the Process Data Value. Each child device elements setpoint work
state is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element setpoint work states can be contained in one setpoint
condensed work state of their parent device element. If less than 16
child device element setpoint work states are available, then the
unused bits shall be set to value 11 (no change). When the parent
device element contains the Setpoint Condensed Work State DDE,
then the device descriptor shall not contain the individual setpoint
work state DDEs in the child device elements.

Comment See the Setpoint Work State DDI (289) attachment for backwards
compatibility and implementation guidelines.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Jaap van Bergeijk
Submit Date 2012-01-19
Submit Company AGCO corporation
Revision Number 1
Current Status ISO-Published
Status Date 2012-04-02
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 240/572

DD Entity 306 - True Rotation Point X-Offset


Definition X direction offset of the device rotation point relative to the DRP.
Comment For devices with more than one axle the rotation point can be located
at another position within the device than the DRP. In this case, the
True Rotation Point X and Y Offset DDIs shall be used to define the
location of the rotation point on the device. Both DDI's shall be
attached to the device element of type Device.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-06-05
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-07-03
Status Comments
Attachment 2012-07-03: - ISO11783-11-DDI-306-True Rotation Point-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 241/572

DD Entity 307 - True Rotation Point Y-Offset


Definition Y direction offset of the device rotation point relative to the DRP.
Comment For devices with more than one axle the rotation point can be located
at another position within the device than the DRP. In this case, the
True Rotation Point X and Y Offset DDIs shall be used to define the
location of the rotation point on the device. Both DDI's shall be
attached to the device element of type Device. See also attachment
of True Rotation Point X-Offset, DDI 306.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-06-05
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2012-07-03
Status Comments

DD Entity 308 - Actual Percentage Application Rate


Definition Actual Application Rate expressed as percentage
Comment Counterpart to DDI 140 (Percentage Application Rate Setpoint)
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 242/572

Display Range 0 - 2147483647


Submit by Jan Steenbock
Submit Date 2012-06-05
Submit Company 98 - Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-07-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 243/572

DD Entity 309 - Minimum Percentage Application Rate


Definition Minimum Application Rate expressed as percentage
Comment Supplied by device as physical minimum, see also DDI 140.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-07-03
Submit Company John Deere
Revision Number 1
Current Status Request Pending
Status Date 2012-07-03
Status Comments

DD Entity 310 - Maximum Percentage Application Rate


Definition Maximum Application Rate expressed as percentage
Comment Supplied by device as physical maximum, see also DDI 140.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2012-07-03
Submit Company John Deere
Revision Number 1
Current Status Request Pending
Status Date 2012-07-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 244/572

DD Entity 311 - Relative Yield Potential


Definition Relative yield potential provided by a FMIS or a sensor or entered by
the operator for a certain task expressed as percentage.
Comment Relative yield potential could be used as input for an intelligent unit to
calculate the appropriate amount of fertilizer / seed / etc. more
accurate. Typical range is 80 to 120%. Expressed in ppm this is
800,000 to 1,200,000.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-07-26
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status Not Specified
Status Date 2012-08-27
Status Comments

DD Entity 312 - Minimum Relative Yield Potential


Definition Minimum potential yield expressed as percentage.
Comment This DDIs is used by the system to provide information about its
value range support for relative yield potential.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-07-29
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-08-27
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 245/572

DD Entity 313 - Maximum Relative Yield Potential


Definition Maximum potential yield expressed as percentage.
Comment This DDIs is used by the system to provide information about its
value range support for relative yield potential.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-08-27
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status Request Pending
Status Date 2012-08-27
Status Comments

DD Entity 314 - Actual Percentage Crop Dry Matter


Definition Actual Percentage Crop Dry Matter expressed as parts per million.
Comment This DDE defines the actual percentage of dry matter in the
harvested crop.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
17 - Sensor System
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-09-17
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-09-24
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 246/572

DD Entity 315 - Average Percentage Crop Dry Matter


Definition Average Percentage Crop Dry Matter expressed as parts per million.
Comment This DDE defines the average percentage of dry matter in the
harvested crop.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
17 - Sensor System
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-09-17
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-09-24
Status Comments

DD Entity 316 - Effective Total Fuel Consumption


Definition Accumulated total fuel consumption in working position.
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-09-17
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-09-24
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 247/572

DD Entity 317 - Ineffective Total Fuel Consumption


Definition Accumulated total fuel consumption in non working position.
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-09-17
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-09-24
Status Comments

DD Entity 318 - Effective Total Diesel Exhaust Fluid Consumption


Definition Accumulated total Diesel Exhaust Fluid consumption in working
position.
Comment Example: Diesel Exhaust Fluid as specified per ISO22241.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 248/572

Submit by Martin Sperlich


Submit Date 2012-09-17
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2012-09-24
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 249/572

DD Entity 319 - Ineffective Total Diesel Exhaust Fluid Consumption


Definition Accumulated total Diesel Exhaust Fluid consumption in non working
position.
Comment Example: Diesel Exhaust Fluid as specified per ISO22241.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2012-09-24
Submit Company CLAAS Agrosystems GmbH & Co. KG
Revision Number 1
Current Status Request Pending
Status Date 2012-09-24
Status Comments

DD Entity 320 - Last loaded Weight


Definition Last loaded Weight value specified as mass
Comment After a loading Procedure, this DDI sends the loaded Mass.

For more information see attachment located at Last loaded Weight


DDE
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 250/572

Submit Date 2013-01-14


Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status Published
Status Date 2020-05-18
Status Comments Correct link in attachment
Attachment 2020-05-18: Trigger method update -
ISO_11783-11-DDI-320-Weighing_Load_Unload-v5.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 251/572

DD Entity 321 - Last unloaded Weight


Definition Last unloaded Weight value specified as mass
Comment After a unloading Procedure, this DDI sends the unloaded Mass.

For more information see attachment located at Last loaded Weight


DDE
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2013-01-14
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2013-02-04
Status Comments

DD Entity 322 - Load Identification Number


Definition The Load Identification Number as a decimal number in the range of
0 to 2147483647. Note that the value of this DDI has the limitation of
being an signed 32 bit number.
Comment The DDI Load Identification Number can be used together with the
DDI “320 - Last loaded Weight― to document the loading of
material on a weighing system. See also the attached document for
more details.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 252/572

CANBus Range -2147483648 - 2147483647


Display Range -2147483648 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2013-05-21
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status Published
Status Date 2024-03-05
Status Comments Change of value range to signed integer format
Attachment 2013-09-22: -
ISO11783-11-DDI-322-Load_Identification_Number_v1-v2.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 253/572

DD Entity 323 - Unload Identification Number


Definition The Unload Identification Number as a decimal number in the range
of 0 to 2147483647. Note that the value of this DDI has the limitation
of being an unsigned 32 bit number.
Comment The DDI Unload Identification Number can be used together with the
DDI “321 - Last Unloaded Weight― to document the unloading
of material on a weighing system. See also the attached document
for more details.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2013-07-15
Submit Company 367 - Fliegl Agratechnik GmbH
Revision Number 1
Current Status Request Pending
Status Date 2013-07-15
Status Comments
Attachment 2013-07-15: -
ISO11783-11-DDI-323-Unload_Identification_Number_v1-v1.pdf

DD Entity 324 - Chopper Engagement Total Time


Definition Accumulated time while the chopping mechanism is engaged
Comment This DDE represents the total engagement time of the chopping
mechanism of the machine and is recommended to be used at
maximum once within the device description in the device element
that represents the machine.
This DDE is designated for the chopping unit of a forage harvester. It
could be also used for the straw chopper of a harvester. For combine
harvesters please also see DDE 236 Threshing Engagement Total
Time.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 254/572

Unit Symbol s - Time count


Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Martin Sperlich
Submit Date 2013-06-17
Submit Company CLAAS Agrosystems KGaA mbH & Co KG
Revision Number 1
Current Status ISO-Published
Status Date 2013-07-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 255/572

DD Entity 325 - Lifetime Application Total Volume


Definition Entire Application Total Volume of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.
The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.
The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
9 - Forage harvester
10 - Irrigation
Unit Symbol L - Capacity count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Michael Köcher
Submit Date 2013-09-02
Submit Company AMAZONE
Revision Number 1
Current Status ISO-Published
Status Date 2013-09-27
Status Comments

DD Entity 326 - Setpoint Header Speed


Definition The setpoint rotational speed of the header attachment of a chopper,
mower or combine
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2015-11-27
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 256/572

Current Status ISO-Published


Status Date 2013-12-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 257/572

DD Entity 327 - Actual Header Speed


Definition The actual rotational speed of the header attachment of a chopper,
mower or combine
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2013-12-04
Status Comments

DD Entity 328 - Minimum Header Speed


Definition The minimum rotational speed of the header attachment of a
chopper, mower or combine
Comment This is a value recommented by the manufacturer of the machine as
the minimum
speed (unlike 0) for a propper working
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 258/572

DD Entity 329 - Maximum Header Speed


Definition The maximum rotational speed of the header attachment of a
chopper, mower or combine
Comment This is a value recommented by the manufacturer of the machine as
the maximum speed the machine is able to offer
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

DD Entity 330 - Setpoint Cutting drum speed


Definition The setpoint speed of the cutting drum of a chopper
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 259/572

DD Entity 331 - Actual Cutting drum speed


Definition The actual speed of the cutting drum of a chopper
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

DD Entity 332 - Minimum Cutting drum speed


Definition The minimum speed of the cutting drum of a chopper
Comment This is a value recommented by the manufacturer of the machine as
the minimum
speed (unlike 0) for a propper working
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 260/572

DD Entity 333 - Maximum Cutting drum speed


Definition The maximum speed of the cutting drum of a chopper
Comment This is a value recommented by the manufacturer of the machine as
the maximum speed the machine is able to offer
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Unit Symbol /s - Quantity per time unit
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

DD Entity 334 - Operating Hours Since Last Sharpening


Definition This value describes the working hours since the last sharpening of
the cutting device.
Comment As the sharpness of the cutting drums cutters on a harvester is an
important indicator for cutting quality and an important factor for the
fuel usage, this value provides information about quality and
effectivity of the harvesting process
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 261/572

DD Entity 335 - Front PTO hours


Definition The hours the Front PTO of the machine was running for the current
Task
Comment This value provides information of the active working time for
example of the header attachment of a selfpropelled machine
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

DD Entity 336 - Rear PTO hours


Definition The hours the Rear PTO of the machine was running for the current
Task
Comment This value provides information of the active working time for
example the rear PTO of a machine.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 262/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2014-01-17
Submit Company John Deere
Revision Number 2
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 263/572

DD Entity 337 - Lifetime Front PTO hours


Definition The hours the Front PTO of the machine was running for the lifetime
of the machine
Comment This value provides information of the active working time for
example of the header attachment of a selfpropelled machine
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
Unit Symbol h - Hour
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,0 - 214748364,7
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

DD Entity 338 - Lifetime Rear PTO Hours


Definition The hours the Rear PTO of the machine was running for the lifetime
of the machine
Comment This value provides information of the active working time for
example the rear PTO of a machine.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 264/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol h - Hour
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,0 - 214748364,7
Submit by Meyer Matthias
Submit Date 2014-01-17
Submit Company John Deere
Revision Number 2
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 265/572

DD Entity 339 - Effective Total Loading Time


Definition The total time needed in the current task to load a product such as
crop.
Comment
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

DD Entity 340 - Effective Total Unloading Time


Definition The total time needed in the current task to unload a product crop.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-01-17
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 266/572

DD Entity 341 - Setpoint Grain Kernel Cracker Gap


Definition The setpoint gap (distance) of the grain kernel cracker drums in a
chopper.
Comment The gap (distance) of the grain kernel cracker is an indicator to the
quality of chopped corn.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2013-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2014-02-24
Status Comments

DD Entity 342 - Actual Grain Kernel Cracker Gap


Definition The actual gap (distance) of the grain kernel cracker drums in a
chopper
Comment The actual gap (distance) of the grain kernel cracker is an indicator to
the quality of chopped corn.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2014-02-25
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-02-25
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 267/572

DD Entity 343 - Minimum Grain Kernel Cracker Gap


Definition The minimum gap (distance) of the grain kernel cracker drums in a
chopper
Comment The minimum gap (distance) of the grain kernel cracker that can be
adjusted
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2014-02-25
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-02-25
Status Comments

DD Entity 344 - Maximum Grain Kernel Cracker Gap


Definition The maximum gap (distance) of the grain kernel cracker drums in a
chopper
Comment The maximum gap (distance) of the grain kernel cracker that can be
adjusted.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2014-02-25
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-02-25
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 268/572

DD Entity 345 - Setpoint Swathing Width


Definition This is the setpoint swathing width of the swath created by a raker.
Comment For mowers the working width DDIs will represent the width of the
mower whereas swathing width will represent the swath with created
by the mover.
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2014-03-17
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-03-25
Status Comments

DD Entity 346 - Actual Swathing Width


Definition This is the width of the swath currently created by a raker.
Comment For mowers the working width DDIs will represent the width of the
mower whereas swathing width will represent the swath width created
by the mover.
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2014-03-17
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-03-25
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 269/572

DD Entity 347 - Minimum Swathing Width


Definition This is the minimum swath width the raker can create.
Comment For mowers the working width DDIs will represent the width of the
mower whereas swathing width will represent the swath width created
by the mover.
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2014-03-17
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-03-25
Status Comments

DD Entity 348 - Maximum Swathing Width


Definition This is the maximum with of the swath the raker can create.
Comment For mowers the working width DDIs will represent the width of the
mower whereas swathing width will represent the swath width created
by the mover.
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2014-03-17
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2014-03-25
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 270/572

DD Entity 349 - Nozzle Drift Reduction


Definition The Nozzle Drift Reduction classification value of the spraying
equipment as percentage

Comment The use of this DDE is to document the current used drift reducing
classification of the nozzles or combination of drift reducing
technique as percentage value.
To record documentation obligation product during applying in
adjacency of sensitive areas.
For more information about nozzle drift classification see also
Standard ISO 22369-1 "Crop protection equipment - Drift
classification of spraying equipment"
Typically used by Device 6 - Sprayers
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 100
Display Range 0 - 100
Submit by Matthias Meyer
Submit Date 2014-06-18
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2014-06-18
Status Comments

DD Entity 350 - Function or Operation Technique


Definition The Function or Operation Technique DDE can be used to define the
operation technique or functionality performed by a device element
defined within the DDOP. The values to be used are defined in the
attached document.
Comment In a DDOP (Device Description Object Pool) of an ISOBUS device
there are different functionalities covered. The device element types
in the Task Controller standard which are Device, Function, Bin,
Section, Unit, Connector Type, and Navigation Reference do not last
out for certain or more complex devices to describe all information in
a unique way to the Task Controller Server. For more information see
the attached document.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 271/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2014-07-01
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2018-04-09
Status Comments In Version 6 a function for proprietary usage was added
Attachment 2019-03-27: Version 7: add Pellets to Baling -
ISO11783-11-DDI-350-Function and Operation Technique
Type-v8.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 272/572

DD Entity 351 - Application Total Volume in [ml]


Definition Accumulated Application specified as volume in milliliter [ml]
Comment is a counter of a device element
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2014-07-02
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2014-07-02
Status Comments

DD Entity 352 - Application Total Mass in gram [g]


Definition Accumulated Application specified as mass in gram [g]
Comment is a counter of a device element
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2014-07-02
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2014-07-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 273/572

DD Entity 353 - Total Application of Nitrogen [N2]


Definition Accumulated application of nitrogen [N2] specified as gram [g]
Comment This total is a counter of a device element
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2014-06-04
Submit Company Zunhammer
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added device class 25

DD Entity 354 - Total Application of Ammonium


Definition Accumulated application of ammonium [NH4] specified as gram [g]
Comment This total is a counter of a device element
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2014-06-04
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added device class 25

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 274/572

DD Entity 355 - Total Application of Phosphor


Definition Accumulated application of phosphor (P2O5) specified as gram [g]
Comment This total is a counter of a device element
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2014-06-04
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added device class 25

DD Entity 356 - Total Application of Potassium


Definition Accumulated application of potassium [K] specified as gram [g]
Comment This total is a counter of a device element
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2014-06-04
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2021-10-25
Status Comments Change unit name from K2 to K only

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 275/572

DD Entity 357 - Total Application of Dry Matter


Definition Accumulated application of dry matter in kilogram [kg]. Dry matter
measured at zero percent of moisture
Comment This total is a counter of a device element
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2014-06-04
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added device class 25

DD Entity 358 - Average Dry Yield Mass Per Time


Definition Average Yield expressed as mass per unit time, corrected for the
reference moisture percentage DDI 184. This value is the average for
a Task and may be reported as a total.
Comment This Average Dry Yield Mass Per Time is the mass flow that has
been corrected for the average crop moisture (DDI 262) based on the
reference moisture for dry mass (DDI 184). This is the "dry"
equivalent to DDI 261. This average yield mass per time is calculated
as the yield total dry mass (DDI 183) divided by the effective total
time (DDI 119) of the active task. When resuming a task, the working
set shall compute its average dry yield mass per time from the yield
total mass (DDI 90), average crop moisture (DDI 262), reference
moisture percentage (DDI 184), and effective total time (119)
assuming these DDI's are sent by the task controller.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Tony Woodcock
Submit Date 2014-08-08
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 276/572

Status Date 2014-08-26


Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 277/572

DD Entity 359 - Average Dry Yield Mass Per Area


Definition Average Yield expressed as mass per unit area, corrected for the
reference moisture percentage DDI 184. This value is the average for
a Task and may be reported as a total.
Comment This Average Dry Yield Mass Per Area is the mass flow that has been
corrected for the average crop moisture (DDI 262) based on the
reference moisture for dry mass (DDI 184). This is the "dry"
equivalent to DDI 263. This average yield mass per area is calculated
as the yield total dry mass (DDI 183) divided by the total area (DDI
116) of the active task. When resuming a task, the working set shall
compute its average dry yield mass per area from the yield total mass
(DDI 90), average crop moisture (DDI 262), reference moisture
percentage (DDI 184), and total area (DDI 116) assuming these
DDI's are sent by the task controller.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Tony Woodcock
Submit Date 2014-08-08
Submit Company Ag Leader Technology
Revision Number 1
Current Status ISO-Published
Status Date 2014-08-26
Status Comments

DD Entity 360 - Last Bale Size


Definition The bale size of the most recently produced bale. Bale Size as length
for a square baler or diameter for a round baler.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler can add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 278/572

Display Range 0 - 2147483647


Submit by Lynn Derynck
Submit Date 2014-11-07
Submit Company CNH Industrial N.V.
Revision Number 1
Current Status ISO-Published
Status Date 2014-12-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 279/572

DD Entity 361 - Last Bale Density


Definition The bale density of the most recently produced bale.

Unit: mg/l (mass per unit volume)


Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler can add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lynn Derynck
Submit Date 2014-11-07
Submit Company CNH Industrial N.V.
Revision Number 1
Current Status ISO-Published
Status Date 2014-12-03
Status Comments

DD Entity 362 - Total Bale Length


Definition Gives the total baled meters during a task. This is calculated as the
sum of the lengths of all knotted bales (square baler).
Comment
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lynn Derynck
Submit Date 2014-11-07
Submit Company CNH Industrial N.V.
Revision Number 1
Current Status ISO-Published
Status Date 2014-12-03
Status Comments
Attachment 2014-11-07: - ISO_11783-11_DDIdentifier_Total Bale Length-v1.doc

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 280/572

DD Entity 363 - Last Bale Dry Mass


Definition The dry mass of the bale that has most recently been produced. This
is the bale mass corrected for the average moisture of this bale (DDI
212).
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol g - Mass large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lynn Derynck
Submit Date 2014-11-07
Submit Company CNH Industrial N.V.
Revision Number 1
Current Status ISO-Published
Status Date 2014-12-03
Status Comments
Attachment 2014-11-07: - ISO_11783-11_DDIdentifier Last Bale Mass
Dry-v1.doc

DD Entity 364 - Actual Flake Size


Definition Actual size of the flake that is currently produced by the chamber.
Comment The recommended use of this DDE is for a baler to report this once
for each new flake that entered
the baler chamber and obtained at the maximum compression of the
plunger. A baler may add this to its default set of data, based on an
internal on-change data trigger that causes the baler to report the
value of this DDE at each new flake.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 1000
Display Range 0 - 1000
Submit by Lynn Derynck
Submit Date 2014-11-07
Submit Company CNH Industrial N.V.
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 281/572

Current Status ISO-Published


Status Date 2015-01-13
Status Comments
Attachment 2014-11-07: - ISO_11783-11_DDIdentifier_ Flake Size-v1.doc

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 282/572

DD Entity 365 - Setpoint Downforce Pressure


Definition Setpoint downforce pressure for an operation
Comment This value represents the system pressure to produce the downforce
(or upforce) for an operation messured in Pa (Pascal); In case of an
negative value the system pressure would produce Upforce.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Brandon McDonald
Submit Date 2014-12-04
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2015-01-13
Status Comments

DD Entity 366 - Actual Downforce Pressure


Definition Actual downforce pressure for an operation
Comment This value represents the actual system pressure to produce the
downforce (or upforce) for an operation messured in Pa (Pascal); In
case of an negative value the system pressure would produce
Upforce.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Brandon McDonald
Submit Date 2014-12-04
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2015-01-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 283/572

DD Entity 367 - Condensed Section Override State (1-16)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 1 to 16 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 284/572

Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2014-11-18
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status ISO-Published
Status Date 2016-06-27
Status Comments Status was published

DD Entity 368 - Condensed Section Override State (17-32)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 17 to 32 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 285/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-20
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 286/572

DD Entity 369 - Condensed Section Override State (33-48)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 33 to 48 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 287/572

SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-20
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the description by ASCII Character for
better processability of the txt export

DD Entity 370 - Condensed Section Override State (49-64)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 49 to 64 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 288/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-20
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the description by ASCII Character for
better processability of the txt export

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 289/572

DD Entity 371 - Condensed Section Override State (65-80)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 65 to 80 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 290/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

DD Entity 372 - Condensed Section Override State (81-96)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 291/572

Definition This DDE is used by the implement to communicate that a certain


section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 81 to 96 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 292/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Section numbers in the definition were wrong

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 293/572

DD Entity 373 - Condensed Section Override State (97-112)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 97 to 112 into a single override state. The
condensed section override state contains the child element override
states, in the driving direction from left to right, where the leftmost
child element override state are the 2 lowest significant bits of the
Process Data Value. Each child device elements override state is
represented by 2 bits and defined as: 00 = section is not overridden,
01 = section is overridden, 10 = reserved, 11 = undefined / not
installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 294/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export.
The Section numbers in the definition were wrong

DD Entity 374 - Condensed Section Override State (113-128)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 295/572

Definition This DDE is used by the implement to communicate that a certain


section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 113 to 128 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 296/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export.
Section numbers in the definition were wrong

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 297/572

DD Entity 375 - Condensed Section Override State (129-144)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 129 to 144 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 298/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export.
Section numbers in the definition were wrong.

DD Entity 376 - Condensed Section Override State (145-160)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 299/572

Definition This DDE is used by the implement to communicate that a certain


section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 145 to 160 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 300/572

CANBus Range 0 - 4294967295


Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 301/572

DD Entity 377 - Condensed Section Override State (161-176)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 161 to 176 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 302/572

SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

DD Entity 378 - Condensed Section Override State (177-192)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 177 to 192 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 303/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 304/572

DD Entity 379 - Condensed Section Override State (193-208)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 193 to 208 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 305/572

SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

DD Entity 380 - Condensed Section Override State (209-224)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 209 to 224 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 306/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 307/572

DD Entity 381 - Condensed Section Override State (225-240)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 225 to 240 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 308/572

SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

DD Entity 382 - Condensed Section Override State (241-256)


Definition This DDE is used by the implement to communicate that a certain
section is overridden and will not follow the section control
commands. The value is a combination of the override states of
individual sections number 241 to 256 into a single override state.
The condensed section override state contains the child element
override states, in the driving direction from left to right, where the
leftmost child element override state are the 2 lowest significant bits
of the Process Data Value. Each child device elements override state
is represented by 2 bits and defined as: 00 = section is not
overridden, 01 = section is overridden, 10 = reserved, 11 = undefined
/ not installed. In total 16 child device element override states can be
contained in one condensed section override state. If less than 16
child device element override states are available, then the unused
bits shall be set to value 11 (undefined / not installed). This DDE shall
be placed in the same device element as the corresponding actual
condensed work state.
Comment It is common for SC servers to show the current state of the sections
in a proprietary screen. As the implement is allowed to override the
commanded state from the task controller it is impossible for the
operator to predict what happens when driving into an unworked
area. With this DDE it is possible for the SC server to show
overridden sections in the proprietary screen.

This DDE shall be defined as DPD in the DDOP of the implement.


The DPD shall at least support the datalog triggers “on change―
and “time based―. The value shall only be sent by the
implement if it was requested (single request or datalog trigger) by
the TC-SC server.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 309/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Michael Köcher
Submit Date 2015-01-21
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status Request Pending
Status Date 2016-06-27
Status Comments Replace character "–" in the DDI Name by ASCII Character for
better processability of the txt export

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 310/572

DD Entity 383 - Apparent Wind Direction


Definition The apparent wind is the wind which is measured on a moving
vehicle. It is the result of two motions: the actual true wind and the
motion of the vehicle. The wind angle is referenced to the present
heading of the vehicle (Zero degree refers to the vehicle driving
direction).
Comment DDI 207 defines the true wind.
DDI 208 defines the true wind angle.
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol ° - Angle
Resolution 1
SAE SPN
CANBus Range 0 - 359
Display Range 0 - 359
Submit by Jan Steenbock
Submit Date 2015-01-12
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 2
Current Status ISO-Published
Status Date 2015-02-10
Status Comments

DD Entity 384 - Apparent Wind Speed


Definition The apparent wind is the wind which is measured on a moving
vehicle. It is the result of two motions: the actual true wind and the
motion of the vehicle.
Comment DDI 207 defines the true wind.
DDI 208 defines the true wind angle.
Typically used by Device 0 - Non-specific system
Class(es) 17 - Sensor System
Unit Symbol mm/s - Speed
Resolution 1
SAE SPN
CANBus Range 0 - 100000000
Display Range 0 - 100000000
Submit by Jan Steenbock
Submit Date 2015-01-12
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 2
Current Status ISO-Published
Status Date 2015-02-10
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 311/572

DD Entity 385 - MSL Atmospheric Pressure


Definition The atmospheric pressure MSL (Mean Sea Level) is the air pressure
related to mean sea level.
Comment In weather charts only the converted pressure to mean sea level is
indicated. Only the pressure changes due to the weather has to be
considered.
Typically used by Device 0 - Non-specific system
Class(es) 17 - Sensor System
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2000000
Display Range 0,0 - 200000,0
Submit by Jan Steenbock
Submit Date 2015-03-30
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-03-30
Status Comments

DD Entity 386 - Actual Atmospheric Pressure


Definition The Actual Atmospheric Pressure is the air pressure currently
measured by the weather station.
Comment This value does take the current altitude (field position) into count.
Typically used by Device 0 - Non-specific system
Class(es) 17 - Sensor System
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2000000
Display Range 0,0 - 200000,0
Submit by Jan Steenbock
Submit Date 2015-03-30
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-03-30
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 312/572

DD Entity 387 - Total Revolutions in Fractional Revolutions


Definition Accumulated Revolutions specified with fractional revolutions
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers.To prevent rounding errors the basic unit r/min where
chosen.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol # - Quantity/Count
Resolution 0,0001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748,3648 - 214748,3647
Submit by Mike Schmidt
Submit Date 2015-04-24
Submit Company AGCO Corporation
Revision Number 1
Current Status ISO-Published
Status Date 2015-04-24
Status Comments

DD Entity 388 - Total Revolutions in Complete Revolutions


Definition Accumulated Revolutions specified as completed integer revolutions
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Mike Schmidt
Submit Date 2015-04-24
Submit Company AGCO Corporation
Revision Number 1
Current Status ISO-Published
Status Date 2015-04-24
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 313/572

DD Entity 389 - Setpoint Revolutions specified as count per time


Definition Setpoint Revolutions specified as count per time
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers. To prevent rounding errors the basic unit r/min where
chosen.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748,3648 - 214748,3647
Submit by David Kuhnel
Submit Date 2015-04-24
Submit Company DICKEY-john Corp
Revision Number 1
Current Status ISO-Published
Status Date 2015-04-24
Status Comments

DD Entity 390 - Actual Revolutions Per Time


Definition Actual Revolutions specified as count per time
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers. To prevent rounding errors the basic unit r/min where
chosen.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748,3648 - 214748,3647
Submit by David Kuhnel
Submit Date 2015-03-23
Submit Company DICKEY-john Corp
Revision Number 1
Current Status ISO-Published
Status Date 2015-03-23
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 314/572

DD Entity 391 - Default Revolutions Per Time


Definition Default Revolutions specified as count per time
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers. To prevent rounding errors the basic unit r/min where
chosen.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748,3648 - 214748,3647
Submit by David Kuhnel
Submit Date 2015-03-23
Submit Company DICKEY-john Corp
Revision Number 1
Current Status ISO-Published
Status Date 2015-03-23
Status Comments

DD Entity 392 - Minimum Revolutions Per Time


Definition Minimum Revolutions specified as count per time
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers. To prevent rounding errors the basic unit r/min where
chosen.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748,3648 - 214748,3647
Submit by David Kuhnel
Submit Date 2015-03-23
Submit Company DICKEY-john Corp
Revision Number 1
Current Status ISO-Published
Status Date 2015-03-23
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 315/572

DD Entity 393 - Maximum Revolutions Per Time


Definition Maximum Revolutions specified as count per time
Comment Forward or Clockwise rotation represented as positive numbers and
reverse or Counter-Clockwise rotation represented by negative
numbers. To prevent rounding errors the basic unit r/min where
chosen.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -214748,3648 - 214748,3647
Submit by David Kuhnel
Submit Date 2015-07-02
Submit Company DICKEY-john Corp
Revision Number 1
Current Status ISO-Published
Status Date 2015-07-02
Status Comments

DD Entity 394 - Actual Fuel Tank Content


Definition The actual content of the fuel tank
Comment This value can be used to see the refilling of the fuel tank or the theft
of fuel.
Typically used by Device 1 - Tractor
Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hans van Zadelhoff
Submit Date 2015-07-02
Submit Company Grimme Landmaschinenfabrik GmbH & Co. KG
Revision Number 2
Current Status ISO-Published
Status Date 2016-09-05
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 316/572

DD Entity 395 - Actual Diesel Exhaust Fluid Tank Content


Definition The actualcontent of the diesel exhaust fluid tank
Comment This value can be used to see the refilling of the diesel exhaust fluid
tank or the theft of diesel exhaust fluid.
Typically used by Device 1 - Tractor
Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hans van Zadelhoff
Submit Date 2015-07-02
Submit Company Grimme Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-07-02
Status Comments

DD Entity 396 - Setpoint Speed


Definition The setpoint speed that can be specified in a process data variable
for communication between farm management information systems
and mobile implement control systems. The setpoint speed DDI may
also be used in a device description object pool to specify support for
speed control by a device. A positive value will represent forward
direction and a negative value will represent reverse direction.
Comment The implementation of speed control on the mobile implement control
system may use other ISO11783 network parameter groups (e.g.
ISO11783-7 Commanded Vehicle Speed and Machine Selected
Speed Setpoint) and may be subject to control request authentication
requirements. The definition of this DDI has been added to the ISO
11783-11 data dictionary to facilitate the specification of a setpoint
speed in a task data transfer file and to enable specification of the
support of speed control in a device description object pool.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 317/572

Typically used by Device 0 - Non-specific system


Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol mm/s - Speed
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Hans van Zadelhoff
Submit Date 2015-02-12
Submit Company Grimme Landmaschinenfabrik GmbH & Co. KG
Revision Number 3
Current Status ISO-Published
Status Date 2015-04-24
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 318/572

DD Entity 397 - Actual Speed


Definition The actual speed as measured on or used by a device for the
execution of task based data, e.g. to convert a setpoint rate
expressed per area to device specific control data that is expressed
as a rate per time. The actual speed can be measured by the device
itself or it can be a speed value that is obtained from one of the speed
parameter groups that are broadcasted on the ISO11783 network
and defined in ISO11783-7. Examples of broadcasted speed
parameter groups are wheel based speed, ground based speed and
machine selected speed. The source of the actual speed can be
specified by a Speed Source DDI that is present in the same device
element as the speed DDI. A positive value will represent forward
direction and a negative value will represent reverse direction.
Comment This DDI has been added to the data dictionary to support logging of
the speed that the device uses for processing and for generation of
task data. The addition of a DDI for actual speed allows speed values
to be added to the default data set that devices present to a task
controller or a data logger.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol mm/s - Speed
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Hans van Zadelhoff
Submit Date 2015-04-24
Submit Company Grimme Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-04-24
Status Comments

DD Entity 398 - Minimum Speed

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 319/572

Definition The minimum speed that can be specified in a process data variable
for communication between farm management information systems
and mobile implement control systems. A positive value will represent
forward direction and a negative value will represent reverse
direction.
Comment This DDI has been added to the data dictionary to support the setting
and logging of a minimum speed for a part of a device. See also the
definitions of the Setpoint, Actual and Maximum Speed DDIs for
additional definition and implementation information of Speed DDIs.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol mm/s - Speed
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Hans van Zadelhoff
Submit Date 2015-09-02
Submit Company Grimme Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-09-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 320/572

DD Entity 399 - Maximum Speed


Definition The maximum speed that can be specified in a process data variable
for communication between farm management information systems
and mobile implement control systems. A positive value will
represent forward direction and a negative value will represent
reverse direction.
Comment This DDI has been added to the data dictionary to support the setting
and logging of a maximum speed for a part of a device. See also the
definitions of the Setpoint, Actual and Minimum Speed DDIs for
additional definition and implementation information of Speed DDIs.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol mm/s - Speed
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Hans van Zadelhoff
Submit Date 2015-09-02
Submit Company Grimme Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-09-02
Status Comments

DD Entity 400 - Speed Source

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 321/572

Definition The Speed Source that the device uses to report actual speed and to
process the setpoint, minimum and maximum speeds. The Speed
Source value is an enumeration with the following definitions:
0 = Unknown
1 = Wheel-based speed
2 = Ground-based speed
3 = Navigation-based speed
4 = Blended speed
5 = Simulated speed
6 = Machine Selected speed
7 = Machine measured speed (This option indicates the machine
uses an own sensor to measures the actual speed, instead of the
speed provided on the bus).
8 to 254 = Reserved

255 = No Source available


Comment The Speed Source DDI can be used in conjunction with the Actual
Speed DDI to specify which speed measurement method is used to
determine the value reported via the Actual, Setpoint, Minimum and
Maximum Speed DDIs. When a device receives commands for
Setpoint, Minimum or Maximum Speed then the Speed Source can
be used to select a ISO 11783-7 command for speed control.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 255
Display Range 0 - 255
Submit by Jaap van Bergeijk
Submit Date 2015-09-02
Submit Company AGCO corporation
Revision Number 2
Current Status Published
Status Date 2018-04-09

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 322/572

Status Comments Change information: 8 to 254 = Reserved

255 = No Source available

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 323/572

DD Entity 401 - Actual Application of Nitrogen [N2] as [mg/l]


Definition Actual application of Nitrogen [N2] specified as milligram per liter
[mg/l]
Comment Is the actual amount of Nitrogen [N2] in liquid manure ( see also DD
Entity 353 )
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2015-09-02
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added unit to name

DD Entity 402 - Actual application of Ammonium


Definition Actual application of Ammonium [NH4] specified as milligram per liter
[mg/l]
Comment Is the actual amount of Ammonium [NH4] in liquig manure ( see also
DD Entity 354 )
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2015-09-02
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments added device class 25

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 324/572

DD Entity 403 - Actual application of Phosphor


Definition Actual application of Phosphor [P2O5] specified as milligram per liter
[mg/l]
Comment Is the actual amount of Phosphor [P2O5] in liquid manure ( see also
DD Entity 355 )
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2015-03-11
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added device class

DD Entity 404 - Actual application of Potassium


Definition Actual application of Potassium [K] specified as gram [g]
Comment is the actual amount of Potassium [K] in liquid manure ( see also DD
Entity 356 )
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2015-09-02
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2021-10-25
Status Comments Change unit name from K2 to K only

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 325/572

DD Entity 405 - Actual application of Dry Matter


Definition Actual application of Dry Matter in kilogram [kg]. Dry matter measured
at Zero percent of moisture.
Comment is the actual amount of Dry matter in liquid manure ( see also DD
Entity 357 )
Typically used by Device 5 - Fertilizer
Class(es) 25 - Slurry Applicators
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Christoph Staub
Submit Date 2015-09-02
Submit Company Zunhammer GmbH
Revision Number 1
Current Status Published
Status Date 2020-07-13
Status Comments Added device class 25

DD Entity 406 - Actual Protein Content


Definition Actual Protein content of a harvested crops
Comment Protein content of harvested crop expressed as a percent mass of the
total crop.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Joe Tevis
Submit Date 2015-09-04
Submit Company Topcon
Revision Number 1
Current Status ISO-Published
Status Date 2015-09-04
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 326/572

DD Entity 407 - Average Protein Content


Definition Average protein content in a harvested crop
Comment Average protein content of harvested crop.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Joe Tevis
Submit Date 2015-09-04
Submit Company Topcon
Revision Number 1
Current Status ISO-Published
Status Date 2015-09-04
Status Comments

DD Entity 408 - Average Crop Contamination


Definition Average amount of dirt or foreign in a harvested crop
Comment Average amount of dirt or foreign in a harvested crop
Typically used by Device 7 - Harvesters
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Ben Craker
Submit Date 2015-09-02
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 327/572

DD Entity 409 - Total Diesel Exhaust Fluid Consumption


Definition Accumulated Diesel Exhaust Fluid Consumption as a Task Total.
Comment This data definition is the Diesel Exhaust Fluid (DEF) consumption
counterpart of the previously defined data dictionary entity 148 - Total
Fuel Consumption. These data dictionary entities can be used by
devices that support data logging of Fuel and Diesel Exhaust Fluid
consumption.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Eric Bongaerts
Submit Date 2015-06-01
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments
Attachment 2015-06-01: - DEF_DDI_Requests-v1.pptx

DD Entity 410 - Instantaneous Diesel Exhaust Fluid Consumption per Time


Definition Diesel Exhaust Fluid consumption per time
Comment This data definition is the Diesel Exhaust Fluid (DEF) consumption
counterpart of the previously defined data dictionary entity 149 -
Instantaneous Fuel Consumption per Time. These data dictionary
entities can be used by devices that support data logging of Fuel and
Diesel Exhaust Fluid consumption.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 328/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Eric Bongaerts
Submit Date 2015-06-01
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 329/572

DD Entity 411 - Instantaneous Diesel Exhaust Fluid Consumption per Area


Definition Diesel Exhaust Fluid consumption per area
Comment This data definition is the Diesel Exhaust Fluid (DEF) consumption
counterpart of the previously defined data dictionary entity 150 -
Instantaneous Fuel Consumption per Area. These data dictionary
entities can be used by devices that support data logging of Fuel and
Diesel Exhaust Fluid consumption.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/m² - Capacity per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Eric Bongaerts
Submit Date 2015-06-01
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

DD Entity 412 - Lifetime Diesel Exhaust Fluid Consumption


Definition Accumulated Diesel Exhaust Fluid Consumption over the entire
lifetime of the device.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 330/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value.

The Device shall support the total trigger method for this DDE but
shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.

This data definition is the Diesel Exhaust Fluid (DEF) consumption


counterpart of the previously defined data dictionary entity 276 -
Lifetime Fuel Consumption. These data dictionary entities can be
used by devices that support data logging of Fuel and Diesel Exhaust
Fluid consumption.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol L - Capacity count
Resolution 0,5
SAE SPN 5963
CANBus Range 0 - 2147483647
Display Range 0 - 1073741823,5
Submit by Eric Bongaerts
Submit Date 2015-06-01
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 331/572

DD Entity 413 - Lifetime Average Diesel Exhaust Fluid Consumption per


Time
Definition Average Diesel Exhaust Fluid Consumption per Time over the entire
lifetime of the device.
Comment This is the overall average of the device. This average does not refer
to an application controlled by a Task Controller. Therefore this DDE
shall not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Device shall support the total trigger method for this DDE but
shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.

This data definition is the Diesel Exhaust Fluid (DEF) consumption


counterpart of the previously defined data dictionary entity 277 -
Lifetime Average Fuel Consumption per Time. These data dictionary
entities can be used by devices that support data logging of Fuel and
Diesel Exhaust Fluid consumption.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/s - Flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Eric Bongaerts
Submit Date 2015-06-01
Submit Company AGCO
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 332/572

Current Status ISO-Published


Status Date 2015-06-16
Status Comments Status was published

DD Entity 414 - Lifetime Average Diesel Exhaust Fluid Consumption per


Area
Definition Average Diesel Exhaust Fluid Consumption per Area over the entire
lifetime of the device.
Comment This is the overall average of the device. This average does not refer
to an application controlled by a Task Controller. Therefore this DDE
shall not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Device shall support the total trigger method for this DDE but
shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.

This data definition is the Diesel Exhaust Fluid (DEF) consumption


counterpart of the previously defined data dictionary entity 278 -
Lifetime Average Fuel Consumption per Area. These data dictionary
entities can be used by devices that support data logging of Fuel and
Diesel Exhaust Fluid consumption.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/m² - Capacity per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 333/572

Display Range 0 - 2147483647


Submit by Eric Bongaerts
Submit Date 2015-06-01
Submit Company AGCO
Revision Number 1
Current Status ISO-Published
Status Date 2015-06-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 334/572

DD Entity 415 - Actual Seed Singulation Percentage


Definition Actual Seed Singulation Percentage calculated from measured seed
spacing using ISO 7256-1 "Quality of Feed Index" algorithm
Comment Reference ISO 7256-1 "Quality of Feed Index" for details on the
standardized method for calculating the seed singulation parameter.
The number of seed drops for calculating this real-time percentage is
not specified due to the possible differences in measurement and
performance of the equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 2
Current Status Published
Status Date 2018-08-28
Status Comments

DD Entity 416 - Average Seed Singulation Percentage


Definition Average Seed Singulation Percentage calculated from measured
seed spacing using ISO 7256-1 "Quality of Feed Index" algorithm.
The value is the average for a Task.
Comment Reference ISO 7256-1 "Quality of Feed Index" for details on the
standardized method for calculating the seed singulation parameter.
The number of seed drops for calculating this real-time percentage is
not specified due to the possible differences in measurement and
performance of the equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 2
Current Status Published
Status Date 2018-08-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 335/572

DD Entity 417 - Actual Seed Skip Percentage


Definition Actual Seed Skip Percentage calculated from measured seed
spacing using ISO 7256-1 "Miss Index" algorithm
Comment Reference ISO 7256-1 "Miss Index" for details on the standardized
method for calculating a percentage. The number of seed drops for
calculating this real-time percentage is not specified due to the
possible differences in measurement and performance of the
equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 2
Current Status Published
Status Date 2018-08-28
Status Comments

DD Entity 418 - Average Seed Skip Percentage


Definition Average Seed Skip Percentage calculated from measured seed
spacing using ISO 7256-1 "Miss Index" algorithm. The value is the
average for a Task.
Comment Reference ISO 7256-1 "Miss Index" for details on the standardized
method for calculating a percentage. The number of seed drops for
calculating this real-time percentage is not specified due to the
possible differences in measurement and performance of the
equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 3
Current Status Published
Status Date 2018-08-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 336/572

DD Entity 419 - Actual Seed Multiple Percentage


Definition Actual Seed Multiple Percentage calculated from measured seed
spacing using ISO 7256-1 "Multiples Index" algorithm.
Comment Reference ISO 7256-1 "Multiples Index" for details on the
standardized method for calculating a percentage. The number of
seed drops for calculating this real-time percentage is not specified
due to the possible differences in measurement and performance of
the equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 3
Current Status Published
Status Date 2018-08-28
Status Comments

DD Entity 420 - Average Seed Multiple Percentage


Definition Average Seed Multiple Percentage calculated from measured seed
spacing using ISO 7256-1 "Multiples Index" algorithm. The value is
the average for a Task.
Comment Reference ISO 7256-1 "Multiples Index" for details on the
standardized method for calculating a percentage. The number of
seed drops for calculating this real-time percentage is not specified
due to the possible differences in measurement and performance of
the equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 3
Current Status Published
Status Date 2018-08-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 337/572

DD Entity 421 - Actual Seed Spacing Deviation


Definition Actual Seed Spacing Deviation from setpoint seed spacing
Comment Deviation is a positive value independently of if distance between
seeds is smaller or larger than the setpoint value
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 3
Current Status Published
Status Date 2018-08-28
Status Comments

DD Entity 422 - Average Seed Spacing Deviation


Definition Average Seed Spacing Deviation from setpoint seed spacing. The
value is the average for a Task.
Comment Deviation is a positive value independently of if distance between
seeds is smaller or larger than the setpoint value
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 3
Current Status Published
Status Date 2018-08-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 338/572

DD Entity 423 - Actual Coefficient of Variation of Seed Spacing Percentage


Definition Actual Coefficient of Variation of Seed Spacing Percentage
calculated from measured seed spacing using ISO 7256-1 algorithm
Comment Reference ISO 7256-1 "Coefficient of Variation" for details on the
standardized method for calculating a percentage. The number of
seed drops for calculating this real-time percentage is not specified
due to the possible differences in measurement and performance of
the equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 3
Current Status Published
Status Date 2018-08-28
Status Comments

DD Entity 424 - Average Coefficient of Variation of Seed Spacing


Percentage
Definition Average Coefficient of Variation of Seed Spacing Percentage
calculated from measured seed spacing using ISO 7256-1 algorithm.
The value is the average for a Task.
Comment Reference ISO 7256-1 "Coefficient of Variation" for details on the
standardized method for calculating a percentage. The number of
seed drops for calculating this real-time percentage is not specified
due to the possible differences in measurement and performance of
the equipment and seeding rates.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 5
Current Status Published
Status Date 2018-08-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 339/572

DD Entity 425 - Setpoint Maximum Allowed Seed Spacing Deviation


Definition Setpoint Maximum Allowed Seed Spacing Deviation
Comment Value is for TIM purposes. An acceptable seeding quality range can
be defined in a task or prescription. Deviation is a positive value
independently of if distance between seeds is smaller or larger than
the setpoint value
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Rothmund
Submit Date 2015-03-25
Submit Company HORSCH
Revision Number 5
Current Status Published
Status Date 2018-08-28
Status Comments

DD Entity 426 - Setpoint Downforce as Force


Definition Setpoint Downforce as Force
Comment This value represents the system pressure to produce the downforce
(or upforce) for an operation messured in newton; In case of an
negative value the system pressure would produce Upforce.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol N - Newton
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Rothmund
Submit Date 2015-09-03
Submit Company HORSCH
Revision Number 1
Current Status ISO-Published
Status Date 2015-09-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 340/572

DD Entity 427 - Actual Downforce as Force


Definition Actual Downforce as Force
Comment This value represents the actual downforce to produce the downforce
(or upforce) for an operation messured in newton; In case of an
negative value the system pressure would produce Upforce.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol N - Newton
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Matthias Rothmund
Submit Date 2015-09-03
Submit Company HORSCH
Revision Number 1
Current Status ISO-Published
Status Date 2015-09-03
Status Comments

DD Entity 428 - Loaded Total Mass


Definition Accumulated Loads specified as mass, not corrected for the
reference moisture percentage DDI 184.
Comment Is a counter of a machine element.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 341/572

DD Entity 429 - Unloaded Total Mass


Definition Accumulated Unloads specified as mass, not corrected for the
reference moisture percentage DDI 184.
Comment Is a counter of a machine element.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-02
Status Comments

DD Entity 430 - Lifetime Loaded Total Mass


Definition Entire Yield Total Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol kg - Mass
Resolution 1
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 342/572

CANBus Range 0 - 2147483647


Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 343/572

DD Entity 431 - Lifetime Unloaded Total Mass


Definition Entire Unloaded Total Mass of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-02
Status Comments

DD Entity 432 - Setpoint Application Rate of Nitrogen [N2]


Definition Setpoint application rate of nitrogen specified as a mass per area
Comment As a reference the toal amount of nitrogen will be documented with
DDE353
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 344/572

Submit by Jan Steenbock


Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 345/572

DD Entity 433 - Actual Application Rate of Nitrogen [N2]


Definition Actual application rate of nitrogen specified as a mass per area
Comment As a reference the toal amount of nitrogen will be documented with
DDE353
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik
Revision Number 2
Current Status ISO-Published
Status Date 2021-02-08
Status Comments Status was published

DD Entity 434 - Minimum Application Rate of Nitrogen [N2]


Definition Minimum application rate of nitrogen specified as a mass per area
Comment As a reference the toal amount of nitrogen will be documented with
DDE353
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 346/572

DD Entity 435 - Maximum Application Rate of Nitrogen [N2]


Definition Maximum application rate of nitrogen specified as a mass per area
Comment As a reference the toal amount of nitrogen will be documented with
DDE353
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 436 - Setpoint Application Rate of Ammonium


Definition Setpoint application rate of Ammonium specified as a mass per area
Comment As a reference the total amount of ammonium will be documented
with DDE354
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 347/572

DD Entity 437 - Actual Application Rate of Ammonium


Definition Actual application rate of Ammonium specified as a mass per area
Comment As a reference the total amount of Ammonium will be documented
with DDE354
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 438 - Minimum Application Rate of Ammonium


Definition Minimum application rate of Ammonium specified as a mass per area
Comment As a reference the total amount of ammonium will be documented
with DDE354
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 348/572

DD Entity 439 - Maximum Application Rate of Ammonium


Definition Maximum application rate of Ammonium specified as a mass per
area
Comment As a reference the total amount of ammonium will be documented
with DDE354
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 440 - Setpoint Application Rate of Phosphor


Definition Setpoint application rate of phosphor specified as a mass per area
Comment As a reference the total amount of phosphor will be documented with
DDE355
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 349/572

DD Entity 441 - Actual Application Rate of Phosphor


Definition Actual application rate of phosphor specified as a mass per area
Comment As a reference the total amount of phosphor will be documented with
DDE355
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 442 - Minimum Application Rate of Phosphor


Definition Minimum application rate of phosphor specified as a mass per area
Comment As a reference the total amount of phosphor will be documented with
DDE355
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 350/572

DD Entity 443 - Maximum Application Rate of Phosphor


Definition Maximum application rate of phosphor specified as a mass per area
Comment As a reference the total amount of phosphor will be documented with
DDE355
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 444 - Setpoint Application Rate of Potassium


Definition Setpoint application rate of potassium specified as a mass per area
Comment As a reference the toal amount of potassium will be documented with
DDE356
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 351/572

DD Entity 445 - Actual Application Rate of Potassium


Definition Actual application rate of potassium specified as a mass per area
Comment As a reference the toal amount of potassium will be documented with
DDE356
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-02
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 446 - Minimum Application Rate of Potassium


Definition Minimum application rate of potassium specified as a mass per area
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2016-03-29
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 352/572

DD Entity 447 - Maximum Application Rate of Potassium


Definition Maximum application rate of potassium specified as a mass per area
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-03
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 448 - Setpoint Application Rate of Dry Matter


Definition Setpoint application rate of dry matter expressed as percentage
Comment As a reference the toal amount of dry matter will be documented with
DDE 357
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steebock
Submit Date 2015-11-03
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 353/572

DD Entity 449 - Actual Application Rate of Dry Matter


Definition Actual application rate of dry matter expressed as percentage
Comment As a reference the toal amount of dry matter will be documented with
DDE 357
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-09-03
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 450 - Minimum Application Rate of Dry Matter


Definition Minimum application rate of dry matter expressed as percentage
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-03
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 354/572

DD Entity 451 - Maximum Application Rate of Dry Matter


Definition Maximum application rate of dry matter expressed as percentage
Comment
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
25 - Slurry Applicators
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Jan Steenbock
Submit Date 2015-11-03
Submit Company Müller-Elektronik GmbH Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 452 - Loaded Total Volume


Definition Accumulated Loaded Volume specified as volume
Comment Is a counter of a machine element
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 355/572

DD Entity 453 - Unloaded Total Volume


Definition Accumulated Unloaded Volume specified as volume
Comment Is a counter of a machine element
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 454 - Lifetime loaded Total Volume


Definition Entire loaded Volume of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 356/572

Unit Symbol L - Capacity count


Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 357/572

DD Entity 455 - Lifetime Unloaded Total Volume


Definition Entire unloaded Volume of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol L - Capacity count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 456 - Last loaded Volume


Definition Last loaded Volume value specified as volume
Comment After a loading Procedure, this DDI sends the loaded Volume.

For more information see attachment located at Last loaded Weight


DDE320

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 358/572

Typically used by Device 4 - Planters /Seeders


Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 359/572

DD Entity 457 - Last unloaded Volume


Definition Last unloaded Volume value specified as volume
Comment After a unloading Procedure, this DDI sends the uloaded Volume.

For more information see attachment located at Last loaded Weight


DDE320
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 458 - Loaded Total Count


Definition Accumulated Loads specified as count
Comment Is a counter of a device element
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 360/572

Current Status ISO-Published


Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 361/572

DD Entity 459 - Unloaded Total Count


Definition Accumulated Unloaded specified as count
Comment Task total of a device element. It shall represent the number of
products being unloaded in one or more unload operations. The
product itself shall be countable. See Unloaded Total Mass (429) or
Unloaded Total Volume (453) if the product isn't countable.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status Published
Status Date 2022-08-09
Status Comments Comment update only!

DD Entity 460 - Lifetime Loaded Total Count


Definition Entire Loaded Total Count of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 362/572

Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 363/572

DD Entity 461 - Lifetime Unloaded Total Count


Definition Entire Unloaded Total Count of the device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 462 - Last loaded Count


Definition Last loaded Count value specified as count
Comment After a loading Procedure, this DDI sends the loaded Count.

For more information see attachment located at Last loaded Weight


DDE320
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 364/572

SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 365/572

DD Entity 463 - Last unloaded Count


Definition Last unloaded Count value specified as count
Comment After a unloading Procedure, this DDI sends the loaded Count.

For more information see attachment located at Last loaded Weight


DDE 320
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-11-03
Status Comments

DD Entity 464 - Haul Counter


Definition Each Time a Device Element is filled and emptied this is called a haul
cycle. This counter counts the cycles
Comment Is a counter of a device element. Can be used to count filling and
emptying cycles. To more precisely document what your device
element is doing, consider to implement DDI 179 Actual Cultural
Practice as well - even if the device has only one operation.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 366/572

Submit Date 2015-07-24


Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status Published
Status Date 2022-08-09
Status Comments Comment update only!

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 367/572

DD Entity 465 - Lifetime Haul Counter


Definition The number of haul cycles done by a machine over its entire lifetime.
This DDE value can not be set through the process data interface but
can be requested and added to a datalog. This DDE value is not
affected by a task based total haul cycles but will increment at the
same rate as the task based total.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changes. It is up to the
device control system when to reset this value.

The Working Set Master shall support the total trigger method for this
DDE but shall not support the setable property.

The Task Controller can request and store this DDE at the end of a
task. But it shall not set this DDE when the task is resumed.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Franz Hoepfinger
Submit Date 2015-07-24
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 2
Current Status ISO-Published
Status Date 2015-12-14
Status Comments

DD Entity 466 - Actual relative connector angle

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 368/572

Definition The DDI Actual relative connector angle shall be placed in the device
element of type connector in the DDOP of the TC-SC Client. The
value describes the actual angle of the longitudinal axis of the
implement relative to the longitudinal axis of the tractor. This angle
should be used by the TC-SC server to calculate the real position of
implement. The TC-SC server may smooth the rendering in any
proprietary screen.
The reference system is the coordinate system of the tractor. This
results in the angles from table 1 of the attachment.
In case of for example a malfunction sensor the error value is set to
0xFExxxxxx.
Comment When working with Section Control it is necessary that the TC-Server
calculates the exact position of the implement and its boom and
sections to mark the covered area on its section control screen
properly. To calculate the positions the TC-SC server uses the x and
y offsets of the DRP and CRP. This works well for mounted and for
non-steered trailed implements but comes up against limits when
implements do have a steering axle or even a steering drawbar
because the TC-SC server can’t know the current steering angle
and moving the DRP doesn’t fit in all means. But this could be
solved when the TC-SC server would knew the exact angle of the
implement related to the tractor. This information could be provided
by the implement because when they have a steering mechanism
they even have a sensor to measure the angle between tractor and
implement.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
25 - Slurry Applicators
Unit Symbol ° - Angle
Resolution 0,001
SAE SPN
CANBus Range -180000 - 180000
Display Range -180,000 - 180,000
Submit by Thomas Konermann
Submit Date 2015-07-27
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number 2
Current Status ISO-Published
Status Date 2016-01-25
Status Comments
Attachment 2015-07-27: - Actual relative connector angle-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 369/572

DD Entity 467 - Actual Percentage Content


Definition Actual Device Element Content specified as percent.
Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,01
SAE SPN
CANBus Range 0 - 10000
Display Range 0,00 - 100,00
Submit by Matthias Meyer
Submit Date 2016-06-13
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

DD Entity 468 - Soil Snow/Frozen Condtion

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 370/572

Definition DDI to document the soil snow / frozen condition.


Meaning of values:
0 - Not defined
1 - Not frozen or snow-covered
2 - Frozen
3 - Snow-covered
>= 4 reserved
For a detailed definition of each state please see the attached
document.
Comment
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Andres Ferreyra / Martin Sperlich
Submit Date 2019-05-28
Submit Company AgConnections / CLAAS
Revision Number 1
Current Status Published
Status Date 2019-07-02
Status Comments
Attachment 2019-07-02: - ISO11783-11-DDI-468-Soil Snow Frozen
Condition-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 371/572

DD Entity 469 - Estimated Soil Water Condtion


Definition DDI to document the estimated soil water condition. Meaning of
values:
0 - Not defined
1 - Dry
2 - Slightly moist
3 - Moist
4 - Very wet
5 - Saturated
6 - Inundated
>= 7 - Reserved
Comment Find a detailed description for each enum value in the attached
document.
To further document ground conditions see also DDI 'Soil
Compaction.
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-6
Display Range 0-6
Submit by Martin Sperlich / Andres Ferreyra
Submit Date 2018-12-17
Submit Company CLAAS / AgConnections
Revision Number 1
Current Status ISO-Published
Status Date 2019-07-02
Status Comments Status was published
Attachment 2019-07-02: - ISO11783-11-DDI-469-Estimated Soil Water
Condition-v1.pdf

DD Entity 470 - Soil Compaction


Definition DDI to document the soil compaction.
Meaning of values:
0 - Not defined
1 - Loose
2 - Slightly compacted
3 - Compacted
4 - Very compacted
>= 5 - Reserved
Comment Find a detailed description for each enum value in the attached
document. To further document ground conditions see also DDI
'Estimated Soil Water Condition'.
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol n.a. -

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 372/572

Resolution 1
SAE SPN
CANBus Range 0-4
Display Range 0-4
Submit by Martin Sperlich / Andres Ferreyra
Submit Date 2018-12-17
Submit Company CLAAS / AgConnections
Revision Number 1
Current Status Published
Status Date 2019-07-02
Status Comments
Attachment 2019-07-02: - ISO11783-11-DDI-470-Soil Compaction-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 373/572

DD Entity 471 - Setpoint Cultural Practice


Definition This DDI is used to define the setpoint cultural practice which is
performed by an individual device operation. For instance a
planter/seeder could provide a sowing and a fertilizing operation at
the same time.

The cultural practice value definitions are: 0=Unknown, 1=Fertilizing,


2=Sowing and Planting, 3=Crop Protection, 4=Tillage, 5=Baling
(Pressing), 6=Mowing, 7=Wrapping, 8=Harvesting, 9=Forage
Harvesting, 10=Transport, 11=Swathing, 12=Slurry/Manure
Application, 13=Self-Loading Wagon, 14=Tedding, 15=Measuring,
16=Irrigation, 17=Feeding/Mixing, 18=Mulching, 19-255=Reserved

See also DDI 179 Actual Cultural Practice for more information and
attachment.
Comment If TC Client has capability of setting and storing cultural practice then
it may allow TC Server to redefine Cultural Practice for any Control
channel via Setpoint Cultural Practice (SCP) DDI for respective
Control channel.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol n.a. -
Resolution 1
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 374/572

CANBus Range 0 - 2147483647


Display Range 0 - 2147483647
Submit by Rajashri Munot
Submit Date 2021-10-26
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2021-12-01
Status Comments First version

DD Entity 472 - Setpoint Length of Cut


Definition Setpoint length of cut for harvested material, e.g. Forage Harvester or
Tree Harvester.
Comment
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status Published
Status Date 2020-04-28
Status Comments Correction bit of bit resolution and Display Range

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 375/572

DD Entity 473 - Minimum length of cut


Definition Minimum length of cut for harvested material, e.g. Forage Harvester
or Tree Harvester.
Comment
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status New Request Submitted
Status Date 2020-04-28
Status Comments Correction of bit resolution and Display Range

DD Entity 474 - Maximum Length of Cut


Definition Maximum length of cut for harvested material, e.g. Forage Harvester
or Tree Harvester.
Comment
Typically used by Device 0 - Non-specific system
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,001 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status Published
Status Date 2020-04-28
Status Comments Correction of bit resolution and Display Range

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 376/572

DD Entity 475 - Setpoint Bale Hydraulic Pressure


Definition The setpoint value of the hydraulic pressure applied to the sides of
the bale in the bale compression chamber.
Comment
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2016-03-21
Status Comments

DD Entity 476 - Minimum Bale Hydraulic Pressure


Definition The minimum value of the hydraulic pressure applied to the sides of
the bale in the bale compression chamber.
Comment
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2016-03-21
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 377/572

DD Entity 477 - Maximum Bale Hydraulic Pressure


Definition The maximum value of the hydraulic pressure applied to the sides of
the bale in the bale compression chamber.
Comment
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol Pa - Pressure
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2016-03-21
Status Comments

DD Entity 478 - Setpoint Flake Size


Definition Setpoint size of the flake to be produced by the chamber.
Comment See also DDI 364.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 1000
Display Range 0 - 1000
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2016-03-21
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 378/572

DD Entity 479 - Minimum Flake Size


Definition Minimum size of the flake that can be produced by the chamber.
Comment See also DDI 364.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 1000
Display Range 0 - 1000
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2016-03-21
Status Comments

DD Entity 480 - Maximum Flake Size


Definition Maximum size of the flake that can be produced by the chamber.
Comment See also DDI 364
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 1000
Display Range 0 - 1000
Submit by Frank Wiebeler
Submit Date 2016-03-21
Submit Company Maschinenfabrik Bernard Krone GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2016-03-21
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 379/572

DD Entity 481 - Setpoint Number of Subbales


Definition Number of smaller bales that shall be included in one bigger bale.
Comment Defines the number of sub-bales included of a big square bale.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-03-09
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

DD Entity 482 - Last Bale Number of Subbales


Definition Number of smaller bales included in the latest produced bale.
Comment This DDI is needed as there might be another bale in the chamber.
When sending this DDI on dropping the bale on the field, the system
can define how many subbales are in that specific bale.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
11 - Transport / Trailers
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-03-09
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 380/572

DD Entity 483 - Setpoint Engine Speed


Definition The setpoint of the rotational speed of the engine.
Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,0000 - 214748,3647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

DD Entity 484 - Actual Engine Speed


Definition Actual rotational speed of the engine.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 381/572

Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,0000 - 214748,3647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 382/572

DD Entity 485 - Minimum Engine Speed


Definition The minimum of the rotational speed of the engine.
Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,0000 - 214748,3647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

DD Entity 486 - Maximum Engine Speed


Definition The maximum of the rotational speed of the engine.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 383/572

Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,0000 - 214748,3647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 384/572

DD Entity 488 - Diesel Exhaust Fluid Tank Percentage Level


Definition The actual level of the Diesel Exhaust Fluid Tank in percent.
Comment The addition of a percentage DDI allows such values to be added to
the default data set that devices present to a task controller or a data
logger
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,01
SAE SPN
CANBus Range 0 - 10000
Display Range 0,00 - 100,00
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

DD Entity 489 - Maximum Diesel Exhaust Fluid Tank Content

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 385/572

Definition This value describes the maximum ammount of Diesel Exhaust fluid,
that can be filled into the tank of the machine
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 386/572

DD Entity 490 - Maximum Fuel Tank Content


Definition This value describes the maximum ammount of fuel that can be filled
into the machines Fuel tank.
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-14
Status Comments

DD Entity 491 - Fuel Percentage Level


Definition The actual level of the machine fuel tank in percent.
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 387/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,01
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,00 - 21474836,47
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-14
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 388/572

DD Entity 492 - Total Engine Hours


Definition The total time the engine was running when the task was active.
Comment For the bit resolution and the CANBus range we do harmonize with
SAE J1939-71 SPN 253 Engine Total Idle Hours
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol h - Hour
Resolution 0,05
SAE SPN
CANBus Range 0 - 4211081215
Display Range 0,00 - 210554060,75
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status Published
Status Date 2020-05-04
Status Comments CANBus Range and Display Range correction

DD Entity 493 - Lifetime Engine Hours


Definition The total time, when the engine was running over the whole lifetime
of the machine.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 389/572

Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol h - Hour
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status
Status Date 2016-04-01
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 390/572

DD Entity 494 - Last Event Partner ID (Byte 1-4)


Definition Last Event Partner ID as a decimal number of 128bit length.

This DDI should include the Byte 1-4 of the Last Event Partner ID. It
should always be sent as Group of 4 DDI's to send all 128 bit
together. After this a DDI 147 “Log Count― shall be sent.

Comment Using Methods do determine the Location of a Vehicle or Storage


which is not equipped with ISOBUS and GPS.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0 - 0xFFFFFFFF
Display Range 0 - 0xFFFFFFFF
Submit by Franz Hoepfinger
Submit Date 2016-07-20
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2015-10-11
Status Comments
Attachment 2016-07-20: - ISO11783-11-DDI-494 Partner ID-v1.pdf

DD Entity 495 - Last Event Partner ID (Byte 5-8)


Definition Last Event Partner ID as a decimal number of 128bit length.

This DDI should include the Byte 5-8 of the Last Event Partner ID. It
should always be sent as Group of 4 DDI's to send all 128 bit
together. After this a DDI 147 “Log Count― shall be sent.
Comment Using Methods do determine the Location of a Vehicle or Storage
which is not equipped with ISOBUS and GPS. See also DDI 494
attachment.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 391/572

Typically used by Device 4 - Planters /Seeders


Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0x00000000 - 0xFFFFFFFF
Display Range 0x00000000 - 0xFFFFFFFF
Submit by Franz Hoepfinger
Submit Date 2015-10-11
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 3
Current Status ISO-Published
Status Date 2016-06-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 392/572

DD Entity 496 - Last Event Partner ID (Byte 9-12)


Definition Last Event Partner ID as a decimal number of 128bit length.

This DDI should include the Byte 9-12 of the Last Event Partner ID. It
should always be sent as Group of 4 DDI's to send all 128 bit
together. After this a DDI 147 “Log Count― shall be sent.
Comment Using Methods do determine the Location of a Vehicle or Storage
which is not equipped with ISOBUS and GPS.
See also DDI 494 attachment.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0x00000000 - 0xFFFFFFFF
Display Range 0x00000000 - 0xFFFFFFFF
Submit by Franz Hoepfinger
Submit Date 2015-10-11
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 3
Current Status ISO-Published
Status Date 2016-06-15
Status Comments

DD Entity 497 - Last Event Partner ID (Byte 13-16)


Definition Last Event Partner ID as a decimal number of 128bit length.

This DDI should include the Byte 13-16 of the Last Event Partner ID.
It should always be sent as Group of 4 DDI's to send all 128 bit
together. After this a DDI 147 “Log Count― shall be sent.
Comment Using Methods do determine the Location of a Vehicle or Storage
which is not equipped with ISOBUS and GPS.
See also DDI 494 attachment.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 393/572

Unit Symbol not defined - not defined


Resolution 1
SAE SPN
CANBus Range 0x00000000 - 0xFFFFFFFF
Display Range 0x00000000 - 0xFFFFFFFF
Submit by Franz Hoepfinger
Submit Date 2015-10-11
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 3
Current Status ISO-Published
Status Date 2016-06-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 394/572

DD Entity 498 - Last Event Partner ID Type


Definition Defines The Type of the Partner ID Device. See Attatchment for
Definition.

Comment See also DDI 494 attachment.


Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0x00000000 - 0xFFFFFFFF
Display Range 0x00000000 - 0xFFFFFFFF
Submit by Franz Hoepfinger
Submit Date 2015-10-11
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 4
Current Status ISO-Published
Status Date 2016-06-20
Status Comments Status was published

DD Entity 499 - Last Event Partner ID Manufacturer ID Code


Definition The Partner ID has to tell its Manufacturer, and the Manufacturer
Numbers from SAE J1939 / ISO 11783 shall be used.
Comment Remark: This is not the Manufacturer of the ISOBUS ECU sending
this DDI to the Task-Controller, but the Manufacturer of the
“Partner― Device.
See also DDI 494 attachment.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 0x00000000 - 0xFFFFFFFF
Display Range 0x00000000 - 0xFFFFFFFF
Submit by Franz Hoepfinger

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 395/572

Submit Date 2015-10-11


Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 4
Current Status ISO-Published
Status Date 2016-06-20
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 396/572

DD Entity 500 - Last Event Partner ID Device Class


Definition This DDI should tell the Device Class of the “Partner― Device.

Comment Look at DDI 494 attachment to get the device class details.

Typically used by Device 4 - Planters /Seeders


Class(es) 5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0x00000000 - 0xFFFFFFFF
Display Range 0x00000000 - 0xFFFFFFFF
Submit by Franz Hoepfinger
Submit Date 2015-10-11
Submit Company 367 - Fliegl Agrartechnik GmbH
Revision Number 4
Current Status ISO-Published
Status Date 2016-06-20
Status Comments Status was published

DD Entity 501 - Setpoint Engine Torque


Definition The setpoint of the engine torque.
Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 397/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 5
Current Status ISO-Published
Status Date 2016-06-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 398/572

DD Entity 502 - Actual Engine Torque


Definition The current torque of the engine.
Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0,000 - 2147483,647
Submit by
Submit Date 2016-04-01
Submit Company
Revision Number 2
Current Status ISO-Published
Status Date 2016-06-28
Status Comments

DD Entity 503 - Minimum Engine Torque


Definition The minimum value of the engine torque

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 399/572

Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2016-06-28
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 400/572

DD Entity 504 - Maximum Engine Torque


Definition The maximum value of the engine torque
Comment
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Frank Wiebeler
Submit Date 2016-06-28
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-06-28
Status Comments

DD Entity 505 - Tramline Control Level


Definition This DDI defines the Tramline Control capability of the Implement.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 401/572

Comment The Implement shall provide in its root DeviceElement which


Tramline Control Levels are supported. The Tramline Control Levels
are independent of each other. It is allowed to support for example
only Level 3 Tramlining.

Byte 1 Bit 0 = 1Support Tramline Control Level 1


Byte 1 Bit 1 = 1Support Tramline Control Level 2
Byte 1 Bit 2 = 1Support Tramline Control Level 3
Byte 1 Bit 3-7 = 0Reserved
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-7
Display Range 0-7
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 3
Current Status Published
Status Date 2023-05-17
Status Comments added new attachment version 1.14
Attachment 2023-05-17: added version 1.14 -
TramlineControl_BasicRequirements_v1.14-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 402/572

DD Entity 506 - Setpoint Tramline Control Level


Definition This DDI defines the Tramline Control capability of the Task
Controller that is used with the appropriate Implement.
Comment The Task Controller shall send this value to inform the Implement
which Tramline Control Level shall be used to operate. In case there
is no match between the supported Tramline Control Level on the
Task Controller Server side and the Implement, the Task Controller
shall inform the Implement by setting the Setpoint Tramline Control
Level to 0.
This is the response to the Tramline Control Level DDI.

0No common Level


1Tramline Control Level 1
2Tramline Control Level 2
3Tramline Control Level 3
4-255Reserved for future Assignment

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

DD Entity 507 - Tramline Sequence Number


Definition This DDI defines a group of DDIs which belong together.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 403/572

Comment In order to ensure that the parameters “Unique A-B Guidance


Reference Line ID―, “Actual Track Number―, “Track
Number to the right― and “Track Number the left― are
belonging together, the Tramline Sequence Number is needed. This
parameter has to be sent from the Tramline Controller to indicate a
new Tramline Sequence to the Implement. This number shall start
with value 1 and increase on every new Tramline Sequence which is
going to be sent.
These Parameters are only allowed to be sent in a group, except the
Unique A-B Guidance Reference Line ID. If one of the parameters is
missing, the Tramline Sequence would be invalid. In case the Unique
A-B Guidance Reference Line ID shall be part of the Tramline
Sequence, this value shall be sent as first value after the Tramline
Sequence Number and before other values.
It is recommended to send all values belonging to one Tramline
Sequence within 500 ms.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 404/572

DD Entity 508 - Unique A-B Guidance Reference Line ID


Definition This DDI defines a unique ID to identify which Guidance Reference
Line is the base for the Tramline calculation.
Comment A field could have more than one Guidance Reference Line. For
example the field could have a Guidance Reference Line for the
headland and also another Guidance Reference Line for the main
field. To distinguish between the several Guidance Reference Lines a
Guidance Reference Line ID is used. This unique ID identifies which
Guidance Reference Line is the base for the Tramline calculation.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

DD Entity 509 - Actual Track Number


Definition This DDI defines a unique number of the Guidance Track the
Implement is currently located on.
Comment The Actual Track Number is the unique Number of the Guidance
Track the Implement is currently located on. This number is provided
by the Guidance System.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 405/572

Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 406/572

DD Entity 510 - Track Number to the right


Definition This DDI defines a unique number of the Guidance Track to right
hand side in direction of Implement orientation.
Comment This is the Guidance Track Number to right hand side in direction of
Implement orientation. If the Track Number to the right is higher than
the Actual Track Number, then the Implement is in the same direction
as the A-B reference line. The Implement orientation is independent
of the driving direction of the Implement. This value is provided by the
Guidance System.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

DD Entity 511 - Track Number to the left


Definition This DDI defines a unique number of the Guidance Track to left hand
side in direction of Implement orientation.
Comment This is the Guidance Track Number to left hand side in direction of
Implement orientation
This value may be used in addition to the Track Number to the right
for differentiating between the two Guidance Track 0 Numbers (0R
and 0L). This value is needed, because there are two cases where
the Actual Track Number and the Track Number to the right are both
0. This value is provided by the Guidance System.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 407/572

Submit Company Competence Center ISOBUS e.V.


Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 408/572

DD Entity 512 - Guidance Line Swath Width


Definition The Swath Width is the Distance between two adjacent Guidance
Lines in a Guidance Pattern.
Comment The User may prefer to choose a distance between two adjacent
Guidance Lines which is a little smaller or bigger than the Seeder
Working Width. The Implement may use this information to apply
correction on its Tramline calculation.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

DD Entity 513 - Guidance Line Deviation


Definition Deviation of the Device-Reference-Point (DRP) to the actual
guidance line, in driving direction.
Comment This DDI shall be sent from the Guidance System or Task Controller.
It specifies the Deviation in mm between the current Guidance Line
and the Device Reference Point which is guided along the Guidance
Line.
The Guidance Line Deviation is positive when the Guidance Line is
located on the right hand side of the Device Reference Point in
driving direction.
The Guidance Line Deviation is negative when the Guidance Line is
located on the left hand side of Device Reference Point in driving
direction.

For more details see also attachment on DDI 505.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 409/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
17 - Sensor System
25 - Slurry Applicators
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 410/572

DD Entity 514 - GNSS Quality


Definition GNSS Quality Identifier to inform the implement about the used
Position Status.
Comment This DDI shall be sent from the Guidance System or Task Controller
to the implement. It specifies the quality of the GNSS which is used
by the Guidance System or Task Controller.

Definition references NMEA2000 Method GNSS parameter as also


mentioned in ISO11783-10.

For more details see also attachment on DDI 505.


Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
17 - Sensor System
25 - Slurry Applicators
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

DD Entity 515 - Tramline Control State

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 411/572

Definition Specifies the actual state of Tramline Control.


The value definitions are:
Byte 1 Bits 0-1 = 00manual/off
Byte 1 Bits 0-1 = 01automatic/on
Byte 1 Bits 0-1 = 10error
Byte 1 Bits 0-1 = 11undefined/not supported
Byte 1 Bits 2-7reserved, set to 0.
The DDI shall support the OnChange trigger so that the Task
Controller is able to get informed when the value gets changed by the
Working Set Master. The Task Controller shall activate this trigger
when using the DDI.
Comment The Tramline Control State has the same purpose and definition like
the Section Control State DDI 160.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-3
Display Range 0-3
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 412/572

DD Entity 516 - Tramline Overdosing Rate


Definition Overdosing Rate for the rows adjacent to the Tramline Track.
Comment This DDI specifies the Overdosing Rate for the rows adjacent to the
Tramline Tracks. This value is specified in ppm. The value 1.000.000
(100%) is the normal rate. A value > 100% means that a overdosing
is applied.
In case of a seeding distance, the implement should calculate the
overdosing based on seeds per area and recalculate that value to an
overdosing seeding rate.
Background: If the seeding distance is just multiplied with the
overdosing rate, the seeding distance will increase which leads to
less seed on the field!
Example: In the case the seeding distance is specified the overdosing
rate will result in a shorter seed distance. A seeding distance of 20,00
cm with an overdosing rate of 110% will result in a seed distance of
18,18cm for the rows adjacent to the Tramline Tracks.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol ppm - Parts per million
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-01
Status Comments

DD Entity 517 - Setpoint Tramline Condensed Work State (1-16)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 413/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 1 to 16 into
a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 1-16 has the same
purpose and definition like the Setpoint Condensed Work State 1-16
DDI 290.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 2
Current Status Published
Status Date 2020-05-04
Status Comments Brackets (1-16) added

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 414/572

DD Entity 518 - Actual Tramline Condensed Work State (1-16)


Definition Combination of the Actual States of individual Tramline Valves
number 1 to 16 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 1-16 has the same
purpose and definition like the Actual Condensed Work State 1-16
DDI 161.

For more details see also attachment on DDI 505.


Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 2
Current Status Published
Status Date 2020-05-04
Status Comments Brackets (1-16) added

DD Entity 519 - Last Bale Lifetime Count


Definition The Lifetime Bale Count of the bale that leaves the machine.
The value shall be equal to the Lifetime Bale Count that was reported
when this bale is knotted.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 415/572

Comment The recommended use of this DDE is for a baler to report this once
for every bale that leaves the machine. A baler can add this to its
default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE when the bale leaves the
machine. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale leaves the machine. The value shall be equal to the Lifetime
Bale Count that was reported when this bale is knotted.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-06-06
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2016-09-19
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 416/572

DD Entity 520 - Actual Canopy Height


Definition Actual height of the canopy above ground.
Comment
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
9 - Forage harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Joe Tevis
Submit Date 2016-10-04
Submit Company Topcon Precision Ag
Revision Number 2
Current Status ISO-Published
Status Date 2018-06-18
Status Comments Status was published

DD Entity 521 - GNSS Installation Type


Definition The GNSS Installation Type DDE is used by the device to provide
additional information about the type and location of the GPS receiver
with reference to the overall system.
Additional information are required especially when more than one
GNSS receiver is installed on the system.
The GPS Installation Type value is an instance enumeration with the
following definitions:
0 = Unknown
1 = Tractor integrated antenna
2 = Tractor universal antenna (removable)
3 = First Implement antenna
4 = Second Implement antenna
5 = Display integrated antenna
6 to 100 Reserved
Comment Today some devices are equipped with more than one GPS receivers
for certain applications. In this case both do have different offset
defined and therefore an application need to be able to identify each
receiver clearly. This DDI does provide the possibility to add these
additional information below the appropriate device element.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 417/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 100
Display Range 0 - 100
Submit by Meyer Matthias
Submit Date 2016-10-17
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2016-11-28
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 418/572

DD Entity 522 - Twine Bale Total Count


Definition The total number of twine bound product units for which Twine
binding method was used during operation.
Comment Twine Total Count can be used as total counter of a device element.
It is intended to be used as task based and therefore it is
recommended to support the on-time and on-change trigger methods.

The total trigger method and the setable property are required for this
DDE.
Note, there is a preferred duplicate DDI 683!
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Elshout
Submit Date 2017-01-26
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status Published
Status Date 2024-02-05
Status Comments Added hint into comment to other DDI 683

DD Entity 523 - Mesh Bale Total Count (Deprecated)


Definition The total number of mesh bound product units for which mesh
binding method was used during operation.
Comment Mesh Total Count can be used as total counter of a device element. It
is intended to be used as task based and therefore it is
recommended to support the on-time and on-change trigger methods.

The total trigger method and the setable property are required for this
DDE. Note, there is a preferred duplicate DDI 682!
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Elshout
Submit Date 2017-01-26
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status Published
Status Date 2024-02-05

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 419/572

Status Comments Added hint into comment to other DDI 682

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 420/572

DD Entity 524 - Lifetime Twine Bale Total Count (Deprecated)


Definition Entire total number of twine bound product units for which Twine
binding method was used during operation, of a device lifetime
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE but shall
not support the setable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Note, there is a preferred duplicate DDI 687!
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Elshout
Submit Date 2017-01-26
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 3
Current Status Published
Status Date 2024-02-05
Status Comments Added hint into comment to other DDI 687

DD Entity 525 - Lifetime Mesh Bale Total Count (Deprecated)


Definition Total number of mesh bound product units for which mesh binding
method was used during operation, of a device lifetime
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE but shall
not support the setable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed. Note, there is a preferred duplicate DDI
686!
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 421/572

Display Range 0 - 2147483647


Submit by Frank Elshout
Submit Date 2017-01-26
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 2
Current Status Published
Status Date 2024-02-05
Status Comments Added hint into comment to other DDI 686

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 422/572

DD Entity 526 - Actual Cooling Fluid Temperature


Definition The actual temperature of the cooling fluid for the machine.
Comment The addition of a DDI for such values allows such values to be added
to the default data set that devices present to a task controller or a
data logger. If not specially defined within a certain function the
assumption is that this DDI represents the engine cooling fluid
temperature.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2016-04-01
Submit Company Maschinenfabrik Bernard Krone
Revision Number 1
Current Status ISO-Published
Status Date 2017-06-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 423/572

DD Entity 528 - Last Bale Capacity


Definition The capacity of the bale that leaves the machine.
The mass used for calculation should be DDI 223 (Last Bale Mass).
The time used for calculation should be the amount of time needed to
produce the bale.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that leaves the machine. A baler can add this to its
default set of data, based on an internal on-change data trigger that
causes the baler to report the value of this DDE when the bale leaves
the machine. The recommendation for data logging is that all "Last
Bale" DDEs that are supported by a device are reported together at
the moment that the bale leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol kg/h - Mass per hour unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Lynn Derynck
Submit Date 2017-03-23
Submit Company CNH Industrial N.V.
Revision Number 1
Current Status Published
Status Date 2017-11-20
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 424/572

DD Entity 529 - Setpoint Tillage Disc Gang Angle


Definition Setpoint Tillage Gang Angle is the pivot angle of the gangs for the
device element
Comment This Serpoint Tillage Gang Angle value represent the angle a tillage
disk or disk gang is set to increase or decrease aggressiveness.
Typical disk angle is measured perpendicular to implement direction.
A single disk angle value typically represents a singular coordinate
system where a single value represents an angle offset from the
perpendicular plane in each quadrant.
See the attachment for more detailed information.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
Unit Symbol ° - Angle
Resolution 0,001
SAE SPN
CANBus Range -180000 - 180000
Display Range -180.0 - 180.0
Submit by Theilen Rick
Submit Date 2017-09-04
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2018-02-14
Status Comments Status was published
Attachment 2018-02-14: - ISO11783-11-DDI-529-Tillage Gang Angle_v_1-v1.pdf

DD Entity 530 - Actual Tillage Disc Gang Angle


Definition Actual Tillage Gang Angle is the pivot angle of the gangs for the
device element.
Comment This Actual Tillage Gang Angle value represent the actual angle of a
tillage disk or disk gang.
Typical disk angle is measured perpendicular to implement direction.
A single disk angle value typically represents a singular coordinate
system where a single value represents an angle offset from the
perpendicular plane in each quadrant.
See the attachment for more detailed information.
Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
Unit Symbol ° - Angle
Resolution 0,001
SAE SPN
CANBus Range -180000 - 180000
Display Range -180.0 - 180.0
Submit by Theilen Rick
Submit Date 2017-09-04
Submit Company John Deere
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 425/572

Current Status Published


Status Date 2018-02-14
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 426/572

DD Entity 531 - Actual Applied Preservative Per Yield Mass


Definition This DDI shall describe the actual applied preservative per harvested
yield mass.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status Published
Status Date 2018-03-19
Status Comments

DD Entity 532 - Setpoint Applied Preservative Per Yield Mass


Definition The desired volume of preservative per harvested yield mass
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 427/572

Typically used by Device 7 - Harvesters


Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 428/572

DD Entity 533 - Default Applied Preservative Per Yield Mass


Definition The default volume of preservative applied per harvested yield mass
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status Published
Status Date 2018-03-19
Status Comments

DD Entity 534 - Minimum Applied Preservative Per Yield Mass


Definition The minimum setable value, the preservative system is able to
control the flow of preservative.
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 429/572

Typically used by Device 7 - Harvesters


Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 430/572

DD Entity 535 - Maximum Applied Preservative Per Yield Mass


Definition The maximum volume, the preservative system can apply to the
harvested yield in a controled way
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
15 - Municipal Work
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm³/kg - Capacity per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

DD Entity 536 - Total Applied Preservative


Definition The total volume of applied preservative, respectively silage additive
in this task.
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 431/572

Typically used by Device 7 - Harvesters


Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
26 - Feeder / Mixer
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status Published
Status Date 2023-04-27
Status Comments Added, respectively silage additive to the definition.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 432/572

DD Entity 537 - Lifetime Applied Preservative


Definition The total applied volume of preservative in the lifetime of the machine
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
12 - Farmyard Work
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
26 - Feeder / Mixer
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

DD Entity 538 - Average Applied Preservative Per Yield Mass


Definition The average volume per mass for this task.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
26 - Feeder / Mixer
Unit Symbol mm³/kg - Capacity per mass unit

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 433/572

Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 434/572

DD Entity 539 - Actual Preservative Tank Volume


Definition The actual volume inside the preservative tank.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
26 - Feeder / Mixer
Unit Symbol ml - Capacity large
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

DD Entity 540 - Actual Preservative Tank Level


Definition The percentage level of the preservative tank.
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
14 - Special Crops
15 - Municipal Work
17 - Sensor System
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
24 - Utility Vehicles
26 - Feeder / Mixer
Unit Symbol ppm - Parts per million
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 435/572

SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Frank Wiebeler
Submit Date 2017-08-01
Submit Company Maschinenfabrik Bernard Krone GmbH&CO KG
Revision Number 1
Current Status ISO-Published
Status Date 2018-03-19
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 436/572

DD Entity 541 - Actual PTO Speed


Definition Actual Speed of the Power Take-Off (PTO)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2018-06-25
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-07-11
Status Comments

DD Entity 542 - Setpoint PTO Speed


Definition The desired Speed of the Power Take-Off (PTO)
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 437/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2018-06-25
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-07-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 438/572

DD Entity 543 - Default PTO Speed


Definition The default Speed of the Power Take-Off (PTO)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2018-06-25
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-07-11
Status Comments

DD Entity 544 - Minimum PTO Speed


Definition The minimum Speed of the Power Take-Off (PTO)
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 439/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2018-06-25
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-07-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 440/572

DD Entity 545 - Maximum PTO Speed


Definition The maximum Speed of the Power Take-Off (PTO)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol r/min - Revolutions per minute
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2018-06-25
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-07-11
Status Comments

DD Entity 546 - Lifetime Chopping Engagement Total Time


Definition Entire Chopping Engagement Total Time of the device lifetime.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 441/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE but shall
not support the setable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol s - Time count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2018-06-25
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-07-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 442/572

DD Entity 547 - Setpoint Bale Compression Plunger Load (N)


Definition The setpoint bale compression plunger load expressed as Newton.
Comment This value is measured / controlled for each new flake that entered
the baler chamber and obtained at the rear dead end of the plunger.
This DDI is also available with a unit of ppm, see DDI 218.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol N - Newton
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2018-08-30
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2018-08-30
Status Comments

DD Entity 548 - Actual Bale Compression Plunger Load (N)


Definition The actual bale compression plunger load expressed as Newton.
Comment This is the plunger load measured at the rear dead end of the plunger
cycle and only updated for each new flake that has entered the baler
chamber. This DDI is also available with a unit of ppm, see DDI 219.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol N - Newton
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2018-08-30
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2018-08-30
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 443/572

DD Entity 549 - Last Bale Average Bale Compression Plunger Load (N)
Definition The average bale compression plunger load for the most recently
produced bale expressed as newton.
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine. This DDI is also available
with a unit of ppm, see DDI 220.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol N - Newton
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Matthias Meyer
Submit Date 2018-08-30
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2018-08-30
Status Comments

DD Entity 550 - Ground Cover


Definition The Ground Cover as an amount of soil that is covered by plants

Comment Here, the cover of the soil with green plants (chlorophyll) is
determined. If there are no plants in the field, the cover is 0%, the soil
is completely covered with plants (leaves), this corresponds to 100%.
The measurement can be determined as described above via
sensors / satellites and calculation of biomass indices or via a camera
system and corresponding image analysis. Soil coverage can now be
used directly to the online application or to create prescription maps.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
25 - Slurry Applicators
Unit Symbol % - Percent
Resolution 0,1
SAE SPN
CANBus Range 0 - 1000

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 444/572

Display Range 0,0 - 100,0


Submit by Johann Janker
Submit Date 2018-06-26
Submit Company Fritzmeier Umwelttechnik GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2018-12-20
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 445/572

DD Entity 551 - Actual PTO Torque


Definition Actual Torque of the Power Take-Off (PTO)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol N*m - Newton metre
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2019-02-05
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-02-11
Status Comments

DD Entity 552 - Setpoint PTO Torque


Definition The desired Torque of the Power Take-Off (PTO)
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 446/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol N*m - Newton metre
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2019-02-05
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-02-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 447/572

DD Entity 553 - Default PTO Torque


Definition The default Torque of the Power Take-Off (PTO)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol N*m - Newton metre
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2019-02-05
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-02-11
Status Comments

DD Entity 554 - Minimum PTO Torque


Definition The minimum Torque of the Power Take-Off (PTO)
Comment

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 448/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol N*m - Newton metre
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2019-02-05
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-02-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 449/572

DD Entity 555 - Maximum PTO Torque


Definition The maximum Torque of the Power Take-Off (PTO)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol N*m - Newton metre
Resolution 0,0001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748,3647
Submit by Marc-Kevin Doeker
Submit Date 2019-02-05
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-02-11
Status Comments

DD Entity 556 - Present Weather Conditions

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 450/572

Definition DDI to document the current weather conditions. Meaning of values:


1 - sunny/clear
2 - partly cloudy
3 - overcast
4 - rain
5 - sleet
6 - snow
Comment For details and source see attached document.
See also DDI 'Previous Weather Conditions'.
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 1-6
Display Range 1-6
Submit by Martin Sperlich / Andres Ferreyra
Submit Date 2018-12-17
Submit Company CLAAS / AgConnectios
Revision Number 1
Current Status Published
Status Date 2019-03-11
Status Comments
Attachment 2019-03-11: - ISO11783-11-DDI-556-Present Weather
Conditions-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 451/572

DD Entity 557 - Setpoint Electrical Current


Definition Setpoint electrical Current of a Device Element
Comment similar to "56 - Setpoint Seeding Depth"
Typically used by Device - Not Assigned
Class(es)
Unit Symbol A - Electrical current
Resolution 0,005
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 10737418,235
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-11
Status Comments

DD Entity 558 - Actual Electrical Current


Definition Actual Electrical Current of Device Element
Comment similar to "57 - Actual Seeding Depth"
Typically used by Device - Not Assigned
Class(es)
Unit Symbol A - Electrical current
Resolution 0,005
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 10737418,235
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 452/572

DD Entity 559 - Minimum Electrical Current


Definition Minimum electrical Current of Device Element
Comment supplied by device as physical minimum

similar to "59 - Minimum Seeding Depth"


Typically used by Device - Not Assigned
Class(es)
Unit Symbol A - Electrical current
Resolution 0,005
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 10737418,235
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-11
Status Comments

DD Entity 560 - Maximum Electrical Current


Definition Maximum electrical Current of Device Element
Comment supplied by device as physical minimum

similar to "60 - Maximum Seeding Depth"


Typically used by Device - Not Assigned
Class(es)
Unit Symbol A - Electrical current
Resolution 0,005
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 10737418,235
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-11
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 453/572

DD Entity 561 - Default Electrical Current


Definition Default electrical current of Device Element
Comment The value which will be used by the device if not set through the Task
Controller.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol A - Electrical current
Resolution 0,005
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 10737418,235
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

DD Entity 562 - Setpoint Voltage


Definition Setpoint Voltage of a Device Element
Comment similar to "56 - Setpoint Seeding Depth"

Typically used by Device - Not Assigned


Class(es)
Unit Symbol V - Electrical voltage
Resolution 0,001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483,648 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 454/572

DD Entity 563 - Default Voltage


Definition Default Voltage of a Device Element
Comment The value that will be used by the device if not set through the TC.

Typically used by Device - Not Assigned


Class(es)
Unit Symbol V - Electrical voltage
Resolution 0,001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483,648 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

DD Entity 564 - Actual Voltage


Definition Actual Voltage of a Device Element
Comment
Typically used by Device 27 - Weeders
Class(es)
Unit Symbol V - Electrical voltage
Resolution 0,001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483,648 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 2
Current Status Published
Status Date 2023-03-28
Status Comments Added Weeders as device class

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 455/572

DD Entity 565 - Minimum Voltage


Definition Minimum Voltage of a Device Element
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol V - Electrical voltage
Resolution 0,001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483,648 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

DD Entity 566 - Maximum Voltage


Definition Maximum Voltage of a Device Element
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol V - Electrical voltage
Resolution 0,001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483,648 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 456/572

DD Entity 567 - Actual Electrical Resistance


Definition Actual Electrical Resistance of Device Element
Comment

Typically used by Device - Not Assigned


Class(es)
Unit Symbol Ohm - Electrical resistance
Resolution 0,01
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 21474836,47
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

DD Entity 568 - Setpoint Electrical Power


Definition Setpoint Electrical Power of Device Element
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol W - Electrical Power
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 457/572

DD Entity 569 - Actual Electrical Power


Definition Actual Electrical Power of Device Element
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol W - Electrical Power
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

DD Entity 570 - Default Electrical Power


Definition Default Electrical Power of Device Element
Comment The value that will be used by the device it not set by the TC.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol W - Electrical Power
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 458/572

DD Entity 571 - Maximum Electrical Power


Definition Maximum Electrical Power of Device Element
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol W - Electrical Power
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

DD Entity 572 - Minimum Electrical Power


Definition Minimum Electrical Power of Device Element
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol W - Electrical Power
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 459/572

DD Entity 573 - Total Electrical Energy


Definition Accumulated Electrical Energy Consumption as a Task Total.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol kWh - Electrical energy
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-14
Status Comments

DD Entity 574 - Setpoint Electrical Energy per Area Application Rate


Definition Setpoint Electrical Energy Application Rate specified as kWh per area
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol kWh/m² - Electrical energy per area
Resolution 0,0000001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214,7483647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 460/572

DD Entity 575 - Actual Electrical Energy per Area Application Rate


Definition Actual Electrical Energy Application Rate specified as kWh per area
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol kWh/m² - Electrical energy per area
Resolution 0,0000001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214,7483647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status ISO-Published
Status Date 2019-03-15
Status Comments Status was published

DD Entity 576 - Maximum Electrical Energy per Area Application Rate


Definition Maximum Electrical Energy Application Rate specified as kWh per
area
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol kWh/m² - Electrical energy per area
Resolution 0,0000001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214,7483647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 2
Current Status Published
Status Date 2021-01-11
Status Comments Typo fixed

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 461/572

DD Entity 577 - Minimum Electrical Energy per Area Application Rate


Definition Minimum Electrical Energy Application Rate specified as kWh per
area
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol kWh/m² - Electrical energy per area
Resolution 0,0000001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214,7483647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

DD Entity 578 - Setpoint Temperature


Definition Setpoint Temperature of Device Element specified as milli Kelvin
Comment Setpoint Temperature of Device Element like a Motor, Engine,
inverter, etc.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 462/572

DD Entity 579 - Actual Temperature


Definition Actual Temperature of Device Element specified as milli Kelvin
Comment Actual Temperature of Device Element like a Motor, Engine, inverter,
etc.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

DD Entity 580 - Minimum Temperature


Definition Minimum Temperature of Device Element specified as milli Kelvin
Comment Minimum Temperature of Device Element like a Motor, Engine,
inverter, etc.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Franz Hoepfinger
Submit Date 2019-03-15
Submit Company Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 463/572

DD Entity 581 - Maximum Temperature


Definition Maximum Temperature of Device Element specified as milli Kelvin
Comment Maximum Temperature of Device Element like a Motor, Engine,
inverter, etc.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Franz Hoepfinger
Submit Date 2019-03-15
Submit Company Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

DD Entity 582 - Default Temperature


Definition Default Temperature of Device Element specified as milli Kelvin
Comment Default Temperature of Device Element like a Motor, Engine, inverter,
etc.
Typically used by Device - Not Assigned
Class(es)
Unit Symbol mK - Temperature
Resolution 1
SAE SPN
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Franz Hoepfinger
Submit Date 2019-03-15
Submit Company Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 464/572

DD Entity 583 - Setpoint Frequency


Definition Setpoint Frequency of Device Element specified as Hz
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol Hz - Electrical frequency
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-18
Status Comments

DD Entity 584 - Actual Frequency


Definition Actual Frequency of Device Element specified as Hz
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol Hz - Electrical frequency
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-18
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 465/572

DD Entity 585 - Minimum Frequency


Definition Minimum Frequency of Device Element specified as Hz
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol Hz - Electrical frequency
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-18
Status Comments

DD Entity 586 - Maximum Frequency


Definition Maximum Frequency of Device Element specified as Hz
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol Hz - Electrical frequency
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Franz Hoepfinger
Submit Date 2019-02-15
Submit Company 973 - Zasso GmbH
Revision Number 1
Current Status Published
Status Date 2019-03-18
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 466/572

DD Entity 587 - Previous Rainfall


Definition DDI to document past rainfall conditions.
Meaning of values:
1 - no rain in the last month
2 - no rain in the last week
3 - no rain in the last 24 hours
4 - rainy without heavy rain in the last 24 hours
5 - heavier rain for some days or rainstorm in the last 24 hours
6 - prolonged rainfall or snowmelt
Comment For details and source see attached document.
See also DDI 'Present Weather Conditions'.
Typically used by Device 0 - Non-specific system
Class(es)
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range 1-6
Display Range 1-6
Submit by Martin Sperlich / Andres Ferreyra
Submit Date 2018-12-17
Submit Company CLAAS / AgConnections
Revision Number 1
Current Status Published
Status Date 2019-04-29
Status Comments
Attachment 2019-04-29: - Previous Rainfall-v1.pdf

DD Entity 588 - Setpoint Volume Per Area Application Rate as [ml/m²]


Definition Setpoint Application Rate specified as volume per area for High
Flows as [mm³/m²]
Comment New DDI which supports higher flows is being needed. Use case:
Manure Application with 28000 gal/acre
Typically used by Device 10 - Irrigation
Class(es) 25 - Slurry Applicators
Unit Symbol ml/m² - Capacity per area large
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Stefan Welsch
Submit Date 2019-04-12
Submit Company 33 - John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2019-05-02
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 467/572

DD Entity 589 - Actual Volume Per Area Application Rate as [ml/m²]


Definition Actual Application Rate specified as volume per area for High Flows
as [ml/m²]
Comment New DDI Request for high flow applications.
Usecase Manure application with 28000 gal/acre
Typically used by Device 10 - Irrigation
Class(es) 25 - Slurry Applicators
Unit Symbol ml/m² - Capacity per area large
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Stefan Welsch
Submit Date 2019-04-12
Submit Company 33 John Deere
Revision Number 1
Current Status Published
Status Date 2019-05-02
Status Comments

DD Entity 590 - Minimum Volume Per Area Application Rate as [ml/m²]


Definition Minimum Application Rate specified as volume per area for High
Flows as [ml/m²]
Comment DDI which supports higher flows is being needed. Use case: Manure
Application with 28000 gal/acre
Typically used by Device 10 - Irrigation
Class(es) 25 - Slurry Applicators
Unit Symbol ml/m² - Capacity per area large
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Stefan Welsch
Submit Date 2019-05-02
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2019-05-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 468/572

DD Entity 591 - Maximum Volume Per Area Application Rate as [ml/m²]


Definition Maximum Volume Per Area Application Rate for high flows as
[ml/m²]
Comment DDI which supports higher flows is being needed. Use case: Manure
Application with 28000 gal/acre
Typically used by Device 10 - Irrigation
Class(es) 25 - Slurry Applicators
Unit Symbol ml/m² - Capacity per area large
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Stefan Welsch
Submit Date 2019-05-02
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2019-05-02
Status Comments

DD Entity 592 - Default Volume Per Area Application Rate as [ml/m²]


Definition Default Volume Per Area Application Rate for high flows as [ml/m²]
Comment DDI which supports higher flows is being needed. Use case: Manure
Application with 28000 gal/acre
Typically used by Device 10 - Irrigation
Class(es) 25 - Slurry Applicators
Unit Symbol ml/m² - Capacity per area large
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Stefan Welsch
Submit Date 2019-05-02
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2019-05-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 469/572

DD Entity 593 - Traction Type


Definition The type of traction system used for a machine.
0 - unknown
1 - Two Track
2 - Four Track
3 - Wheel
4 - Front Track, Rear Wheel
5 - Front Wheel, Rear Track
>= 6 are reserved for future assignments
Comment An example use case for Traction Type is a display system with both
a TC server encountering a tractor and a guidance system that needs
to know the difference between a wheeled or tracked tractor to
determine operating parameters.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
24 - Utility Vehicles
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-5
Display Range 0-5
Submit by Nick Linberg
Submit Date 2019-07-09
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2019-08-13
Status Comments

DD Entity 594 - Steering Type

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 470/572

Definition Steering Type DDI is used to define the current active steering type of
a machine. This information can be used to finetune or adjust system
behavior or to document which steering type was used during
operation.
The current supported steering types are listed below:
0 -- unknown
1 – Articulated
2 – Differential
3 - Front wheel
4 - Rear wheel
5 - Four wheel
6 - Differential Front with Active Rear support
7 – Dog-walk Machine
>=8 are reserved for future assignments

Comment Steering type reported by device for use by guidance systems.


Depending on the DDI implementation and machine capabilities the
Steering Type could change during operation.
For more details and examples see attachment.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
24 - Utility Vehicles
25 - Slurry Applicators
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-7
Display Range 0-7
Submit by Paul Matthews
Submit Date 2020-02-10
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2020-02-10
Status Comments First release
Attachment 2020-02-10: - ISO11783-11-DDI-594-Steering Type-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 471/572

DD Entity 595 - Machine Mode


Definition This mode does represent the overall current machine mode and
shall be used only one time within the DDOP below the device
element of type device.
If a machine is capable of differentiating between different modes it
can be indicated by this mode. The value definitions are
0 = Unknown / Not defined
1 = Idle
2 = Field Mode
3 = Street Mode
4 = Maintenance
5 = Filling
6 = Emptying
7 = Cleaning
8 and higher are reserved for future assignments
Comment In addition to the current workstate, some machines are capable of
differentiating between different modes. In idle/neutral mode, value 1
(Idle) should be used. If a machine is in working/field mode, value 2
(Field Mode) should be indicated. Moving the machine on a
road/street should be indicated by value 3 (Street Mode). During
maintenance/servicing, the value 4 (Maintenance) must be selected.
If the machine is in an unspecified state, value 0 (Unknown / Not
defined) should be used.
Note: this mode does not define the Work State of a machine function
Examples:
* A sprayer in the field performing a spraying application is in field
mode. A sprayer at the farm filling the bin is in filling mode

* A combine harvesting in the field would be in field mode. To indicate


unloading the harvester bin DDI 240 should be used

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 472/572

Typically used by Device - Not Assigned


Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-12-04
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2020-09-21
Status Comments Added mode 5 to 7; Update definition and comment

DD Entity 596 - Cargo Area Cover State

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 473/572

Definition Current state of the Cargo Area Cover. Used to determine whether
the Cargo Area was covered during transport or other activities.
The Cargo Area Cover State is a value from -1 to 100 % . The value
definitions are:
-1 = Not defined/Unknown
0 = cover open
100 = cover fully closed
Comment Used to determine whether the Cargo Area is covered during
transport or other activities. If the Cargo Area is not covered, value 0
(Open) should be used. If the Cargo Area is fully covered, value 100
(Closed) should be used. If the state changes from open to closed -
or vice versa - then a value between 1 and 99 (Intermediate Position)
must be selected. If the status cannot be determined, value -1
(Unknown / Not defined) should be used.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol % - Percent
Resolution 1
SAE SPN
CANBus Range -1 - 100
Display Range -1 - 100
Submit by Marc-Kevin Doeker
Submit Date 2019-12-04

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 474/572

Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG


Revision Number 1
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 475/572

DD Entity 597 - Total Distance


Definition Accumulated Distance (independent of working position and surface)
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-11-19
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

DD Entity 598 - Lifetime Total Distance


Definition Entire Total Distance of the device lifetime (independent of working
position and surface)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 476/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE but shall
not support the setable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol m - Distance
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-11-19
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 477/572

DD Entity 599 - Total Distance Field


Definition Accumulated Distance on the field
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-11-19
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

DD Entity 600 - Lifetime Total Distance Field


Definition Entire Total Distance on the field of the device lifetime

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 478/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE but shall
not support the setable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol m - Distance
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-11-19
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status ISO-Published
Status Date 2019-12-16
Status Comments Status was published

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 479/572

DD Entity 601 - Total Distance Street


Definition Accumulated Distance on the street
Comment
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-11-19
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 602 - Lifetime Total Distance Street


Definition Entire Total Distance on the street of the device lifetime

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 480/572

Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore this DDE shall
not be setable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE but shall
not support the setable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device - Not Assigned
Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol m - Distance
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Marc-Kevin Doeker
Submit Date 2019-11-19
Submit Company Maschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 481/572

DD Entity 603 - Actual Tramline Condensed Work State (17-32)


Definition Combination of the Actual States of individual Tramline Valves
number 17 to 32 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 17-32 has the same
purpose and definition like the Actual Condensed Work State 17-32
DDI 162. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 604 - Actual Tramline Condensed Work State (33-48)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 482/572

Definition Combination of the Actual States of individual Tramline Valves


number 33 to 48 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 33-48 has the same
purpose and definition like the Actual Condensed Work State 33-48
DDI 163. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 483/572

DD Entity 605 - Actual Tramline Condensed Work State (49-64)


Definition Combination of the Actual States of individual Tramline Valves
number 49 to 64 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 49-64 has the same
purpose and definition like the Actual Condensed Work State 49-64
DDI 164. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 606 - Actual Tramline Condensed Work State (65-80)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 484/572

Definition Combination of the Actual States of individual Tramline Valves


number 65 to 80 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 65-80 has the same
purpose and definition like the Actual Condensed Work State 65-80
DDI 165. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 485/572

DD Entity 607 - Actual Tramline Condensed Work State (81-96)


Definition Combination of the Actual States of individual Tramline Valves
number 81 to 96 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 81-96 has the same
purpose and definition like the Actual Condensed Work State 81-96
DDI 166. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 608 - Actual Tramline Condensed Work State (97-112)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 486/572

Definition Combination of the Actual States of individual Tramline Valves


number 97 to 112 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 97-112 has the same
purpose and definition like the Actual Condensed Work State 97-112
DDI 167. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 487/572

DD Entity 609 - Actual Tramline Condensed Work State (113-128)


Definition Combination of the Actual States of individual Tramline Valves
number 113 to 128 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 113-128 has the same
purpose and definition like the Actual Condensed Work State
113-128 DDI 168. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 610 - Actual Tramline Condensed Work State (129-144)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 488/572

Definition Combination of the Actual States of individual Tramline Valves


number 129 to 144 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 129-144 has the same
purpose and definition like the Actual Condensed Work State
129-144 DDI 169. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 489/572

DD Entity 611 - Actual Tramline Condensed Work State (145-160)


Definition Combination of the Actual States of individual Tramline Valves
number 145 to 160 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 145-160 has the same
purpose and definition like the Actual Condensed Work State
145-160 DDI 170. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 612 - Actual Tramline Condensed Work State (161-176)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 490/572

Definition Combination of the Actual States of individual Tramline Valves


number 161 to 176 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 161-176 has the same
purpose and definition like the Actual Condensed Work State
161-176 DDI 171. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 491/572

DD Entity 613 - Actual Tramline Condensed Work State (177-192)


Definition Combination of the Actual States of individual Tramline Valves
number 177 to 192 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 177-192 has the same
purpose and definition like the Actual Condensed Work State
177-192 DDI 172. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 614 - Actual Tramline Condensed Work State (193-208)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 492/572

Definition Combination of the Actual States of individual Tramline Valves


number 193 to 208 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 193-208 has the same
purpose and definition like the Actual Condensed Work State
193-208 DDI 173. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 493/572

DD Entity 615 - Actual Tramline Condensed Work State (209-224)


Definition Combination of the Actual States of individual Tramline Valves
number 209 to 224 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 209-224 has the same
purpose and definition like the Actual Condensed Work State
209-224 DDI 174. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 616 - Actual Tramline Condensed Work State (225-240)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 494/572

Definition Combination of the Actual States of individual Tramline Valves


number 225 to 240 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 225-240 has the same
purpose and definition like the Actual Condensed Work State
225-240 DDI 175. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 495/572

DD Entity 617 - Actual Tramline Condensed Work State (241-256)


Definition Combination of the Actual States of individual Tramline Valves
number 241 to 256 into a single Actual Tramline State of their parent
DeviceElement. The Actual Tramline Condensed Work State contains
the child element Actual Tramline Work States, in the driving direction
from left to right, where the leftmost child element Actual Tramline
Work State are the 2 lowest significant bits of the Process Data
Value. Each child device elements Actual Tramline Work State is
represented by 2 bits and defined as: 00 = disabled/off, 01 =
enabled/on, 10 = error indicator, 11 = undefined/not installed. In total
16 child device element Actual Tramline Work States can be
contained in one Actual Tramline Condensed Work State of their
parent DeviceElement. If less than 16 child device element Actual
Tramline Work States are available, then the unused bits shall be set
to value 11 (not installed).
Comment The Actual Tramline Condensed Work State 241-256 has the same
purpose and definition like the Actual Condensed Work State
241-256 DDI 176. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 618 - Setpoint Tramline Condensed Work State (17-32)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 496/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 17 to 32 into
a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 17-32 has the same
purpose and definition like the Setpoint Condensed Work State 17-32
DDI 291. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 497/572

DD Entity 619 - Setpoint Tramline Condensed Work State (33-48)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 33 to 48 into
a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 33-48 has the same
purpose and definition like the Setpoint Condensed Work State 33-48
DDI 292. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 620 - Setpoint Tramline Condensed Work State (49-64)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 498/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 49 to 64 into
a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 49-64 has the same
purpose and definition like the Setpoint Condensed Work State 49-64
DDI 293. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 499/572

DD Entity 621 - Setpoint Tramline Condensed Work State (65-80)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 65 to 80 into
a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 65-80 has the same
purpose and definition like the Setpoint Condensed Work State 65-80
DDI 294. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 622 - Setpoint Tramline Condensed Work State (81-96)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 500/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 81 to 96 into
a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 81-96 has the same
purpose and definition like the Setpoint Condensed Work State 81-96
DDI 295. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 501/572

DD Entity 623 - Setpoint Tramline Condensed Work State (97-112)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 97 to 112
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 97-112 has the same
purpose and definition like the Setpoint Condensed Work State
97-112 DDI 296. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 624 - Setpoint Tramline Condensed Work State (113-128)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 502/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 113 to 128
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 113-128 has the same
purpose and definition like the Setpoint Condensed Work State
113-128 DDI 297. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 503/572

DD Entity 625 - Setpoint Tramline Condensed Work State (129-144)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 129 to 144
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 129-144 has the same
purpose and definition like the Setpoint Condensed Work State
129-144 DDI 298. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 626 - Setpoint Tramline Condensed Work State (145-160)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 504/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 145 to 160
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 145-160 has the same
purpose and definition like the Setpoint Condensed Work State
145-160 DDI 299. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 505/572

DD Entity 627 - Setpoint Tramline Condensed Work State (161-176)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 161 to 176
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 161-176 has the same
purpose and definition like the Setpoint Condensed Work State
161-176 DDI 300. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 628 - Setpoint Tramline Condensed Work State (177-192)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 506/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 177 to 192
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 177-192 has the same
purpose and definition like the Setpoint Condensed Work State
177-192 DDI 301. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 507/572

DD Entity 629 - Setpoint Tramline Condensed Work State (193-208)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 193 to 208
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 193-208 has the same
purpose and definition like the Setpoint Condensed Work State
193-208 DDI 302. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 630 - Setpoint Tramline Condensed Work State (209-224)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 508/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 209 to 224
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 209-224 has the same
purpose and definition like the Setpoint Condensed Work State
209-224 DDI 303. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 509/572

DD Entity 631 - Setpoint Tramline Condensed Work State (225-240)


Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 225 to 240
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 225-240 has the same
purpose and definition like the Setpoint Condensed Work State
225-240 DDI 304. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

DD Entity 632 - Setpoint Tramline Condensed Work State (241-256)

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 510/572

Definition The Setpoint Tramline Condensed Work State DDIs are the control
command counterparts to the Actual Tramline Condensed Work
States DDIs. The value is a combination of the Setpoint Tramline
Valve Work States of individual Tramline Valves number 241 to 256
into a single Setpoint Tramline Condensed Work State of their parent
DeviceElement. The Setpoint Tramline Condensed Work State
contains the child element Setpoint Tramline Work States, in the
driving direction from left to right, where the leftmost child element
Setpoint Tramline Work State are the 2 lowest significant bits of the
Process Data Value. Each child device elements Setpoint Work State
is represented by 2 bits and defined as: 00 = disable/off, 01 =
enable/on, 10 = error indicator, 11 = no change. In total 16 child
device element Setpoint Tramline Work States can be contained in
one Setpoint Tramline Condensed Work State of their parent
DeviceElement. If less than 16 child device element Setpoint
Tramline Work States are available, then the unused bits shall be set
to value 11 (no change).
Comment The Setpoint Tramline Condensed Work State 241-256 has the same
purpose and definition like the Setpoint Condensed Work State
241-256 DDI 305. For more details see also attachment on DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 4294967295
Display Range 0 - 4294967295
Submit by Dominik Diekmann
Submit Date 2019-12-11
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2019-12-16
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 511/572

DD Entity 633 - Setpoint Volume per distance Application Rate


Definition Setpoint Application Rate specified as volume per distance
Comment Defines a target volume to be sprayed per distance travelled. e.g. in
vineyards, orchards
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Unit Symbol ml/m - Volume per distance
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Stefan Welsch
Submit Date 2020-06-26
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2020-07-14
Status Comments Status was published

DD Entity 634 - Actual Volume per distance Application Rate


Definition Actual liquid application based on distance travelled, e.g. in
vineyards, orchards.
Comment Actual liquid application based on distance travelled, e.g. in
vineyards, orchards.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Unit Symbol ml/m - Volume per distance
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Stefan Welsch
Submit Date 2020-06-26
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2020-07-14
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 512/572

DD Entity 635 - Default Volume per distance Application Rate


Definition Default Application Rate specified as volume per distance
Comment Defines a default volume to be sprayed per distance travelled. e.g. in
vineyards, orchards
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Unit Symbol ml/m - Volume per distance
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Stefan Welsch
Submit Date 2020-07-14
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2020-07-14
Status Comments

DD Entity 636 - Minimum Volume per distance Application Rate


Definition Minimum Application Rate specified as volume per distance
Comment Defines the minimum volume to be sprayed per distance travelled.
e.g. in vineyards, orchards
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Unit Symbol ml/m - Volume per distance
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Stefan Welsch
Submit Date 2020-07-14
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2020-07-14
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 513/572

DD Entity 637 - Maximum Volume per distance Application Rate


Definition Maximum Application Rate specified as volume per distance
Comment Defines the maximum volume to be sprayed per distance travelled.
e.g. in vineyards, orchards
Typically used by Device 5 - Fertilizer
Class(es) 6 - Sprayers
7 - Harvesters
10 - Irrigation
25 - Slurry Applicators
Unit Symbol ml/m - Volume per distance
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Stefan Welsch
Submit Date 2020-07-14
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2020-07-14
Status Comments

DD Entity 638 - Setpoint Tire Pressure


Definition Setpoint Tire Pressure to adjust the pressure of the Tire at the point
of dispensing.
Comment On pressure-based control systems, it is important to be able to
monitor and control the pressure to ensure the proper Tire pressure.
Being able to display and log pressure is important.
Typically used by Device 1 - Tractor
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Rajashri Munot
Submit Date 2020-12-10
Submit Company John Deere
Revision Number 1
Current Status ISO-Published
Status Date 2021-02-11
Status Comments Status was published
Attachment 2021-02-11: - ISO_11783-11-DDI-638-Setpoint Tire Pressure-v1.pdf

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 514/572

DD Entity 639 - Actual Tire Pressure


Definition Actual Tire Pressure is the measured pressure in the tire during
operation.
Comment On pressure-based control systems, it is important to be able to
monitor and control the pressure to ensure the proper performance.
Being able to display and log pressure is important.
Typically used by Device 1 - Tractor
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Rajashri Munot
Submit Date 2020-12-09
Submit Company John Deere
Revision Number 3
Current Status Published
Status Date 2021-04-01
Status Comments Fix typo

DD Entity 640 - Default Tire Pressure


Definition Default Tire Pressure in the tire during operation.
Comment Default Tire Pressure to ensure a stable and safe tire.
Typically used by Device 1 - Tractor
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Rajashri Munot
Submit Date 2020-12-09
Submit Company John Deere
Revision Number 2
Current Status Published
Status Date 2021-04-01
Status Comments Fix typo

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 515/572

DD Entity 641 - Minimum Tire Pressure


Definition Minimum Tire Pressure in the tire at the time of operation
Comment Minimum Tire pressure to ensure a consistent performance.
Typically used by Device 1 - Tractor
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Rajashri Munot
Submit Date 2020-12-09
Submit Company John Deere
Revision Number 2
Current Status Published
Status Date 2021-04-19
Status Comments Typo fix

DD Entity 642 - Maximum Tire Pressure


Definition Maximum Tire Pressure in the tire during operation
Comment Maximum Tire pressure to ensure a stable and safe tire.
Typically used by Device 1 - Tractor
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Unit Symbol Pa - Pressure
Resolution 0,1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 214748364,7
Submit by Rajashri Munot
Submit Date 2020-12-09
Submit Company John Deere
Revision Number 2
Current Status Published
Status Date 2021-04-19
Status Comments Typo fix

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 516/572

DD Entity 643 - Actual Tire Temperature


Definition Actual Tire Temperature is the measured temperature in the tire
during operation.
Comment See also the attachment on DDI 638 Setpoint Tire Pressure to get
more information about potential device description object pools and
where to add Tire DDIs.
Typically used by Device 1 - Tractor
Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Unit Symbol mK - Temperature
Resolution 1
SAE SPN PGN 65268 SPN 242 Tire Temperature
CANBus Range 0 - 1000000
Display Range 0 - 1000000
Submit by Franz Höpfinger
Submit Date 2021-08-02
Submit Company 1116- HR Agrartechnik GmbH
Revision Number 1
Current Status Published
Status Date 2021-08-10
Status Comments

DD Entity 644 - Binding Method


Definition Specification of the method used to bind bales.

The value definitions represent a set of flags.


The flag values are:
0 = unknown (default)
1 = Mesh
2 = Twine
3 = Film
4 = Twine & Mesh
5 = Twine & Film
6 and higher are are reserved for future assignments
Comment This DDE allows a baler to specify what method is being used to bind
the bales.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0-5
Display Range 0-5
Submit by Mike Schmidt on behalf of Steffen Hoffmann

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 517/572

Submit Date 2021-04-20


Submit Company AGCO
Revision Number 2
Current Status New Request Submitted
Status Date 2022-03-21
Status Comments added 4 and 5;

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 518/572

DD Entity 645 - Last Bale Number of Knives


Definition Number of cutting knives used in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2021-09-13
Status Comments

DD Entity 646 - Last Bale Binding Twine Consumption


Definition Binding twine consumption in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 2
Current Status Published
Status Date 2023-04-24
Status Comments Only wording changed from "Twine Binding" to "Binding Twine"

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 519/572

DD Entity 647 - Last Bale Binding Mesh Consumption


Definition Binding mesh consumption in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2022-10-10
Status Comments Added "Binding" to name

DD Entity 648 - Last Bale Binding Film Consumption


Definition Binding film consumption in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2022-10-10
Status Comments Added "Binding" to name

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 520/572

DD Entity 649 - Last Bale Binding Film Stretching


Definition Binding film stretching in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2022-10-10
Status Comments Added "Binding" to name

DD Entity 650 - Last Bale Wrapping Film Width


Definition Wrapping film width in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2021-09-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 521/572

DD Entity 651 - Last Bale Wrapping Film Consumption


Definition Wrapping film consumption in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2021-09-13
Status Comments

DD Entity 652 - Last Bale Wrapping Film Stretching


Definition Wrapping film stretching in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2021-09-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 522/572

DD Entity 653 - Last Bale Wrapping Film Overlap Percentage


Definition Wrapping film overlap percentage in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol % - Percent
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483,647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2021-09-13
Status Comments

DD Entity 654 - Last Bale Wrapping Film Layers


Definition Wrapping film layers in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2021-04-20
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2021-09-13
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 523/572

DD Entity 655 - Electrical Apparent Soil Conductivity


Definition Electrical conductivity also called the EC-Value.

For materials this is a constant.


For material mixes like soil you can measure a apparent conductivity,
which gives information about the soil conditions.

Comment See Attachement for more Info.


Typically used by Device 2 - Primary Soil Tillage
Class(es) 3 - Secondary Soil Tillage
17 - Sensor System
Unit Symbol mS/m - Milli Siemens per meter
Resolution 0,1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -3300.0 - 3300.0
Submit by Franz Höpfinger
Submit Date 2021-04-14
Submit Company 850 - Geoprospectors GmbH
Revision Number 1
Current Status Published
Status Date 2021-10-05
Status Comments
Attachment 2021-10-05: -
ISO_11783-11_DDI-655-Electrical_Apparent_Soil_Conductivity-v1.pd
f

DD Entity 656 - SC Actual Turn On Time


Definition Definition: The Section Control Actual Turn On Time defines the
overall time lapse between the moment the TC client sends the actual
Section state and the moment this section is physically turned on and
the product is applied.

The working set may support this DDE as an optional feature to


provide the possibility to store the time settings direct on the device to
make the settings available after a power cycle. Therefore this DDE
needs always to be settable by the TC and shall not be used to
change any working set system behavior.

The DDI shall support the On Change trigger so that the TC is able to
get informed when the value gets changed by the Working Set
Master. The TC shall activate this trigger when using the DDI.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 524/572

Comment This value should be provided by the implement manufacturer if


applicable and otherwise only DDI 205 "SC Setpoint Turn On Time"
shall be provided. If the system does not define SC Actual Turn On
Time and SC Setpoint Turn On Time separately, it implies that "SC
Setpoint Turn On Time" may be considered for drawing Actual
Coverage. If "SC Actual Turn On Time" is defined as 0, the coverage
ON shall be immediate.
The usage of " SC Actual Turn On Time" does not eliminate usage of
"SC Setpoint Turn On time - DDI 205", it is supporting information for
better coverage Map based on Actual CWS. See also DDI 205
including attachment and DDI 206 and 657
Typically used by Device 1 - Tractor
Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Rajashri Munot
Submit Date 2021-10-14
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2022-01-10
Status Comments First version

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 525/572

DD Entity 657 - SC Actual Turn Off Time


Definition The Section Control Actual Turn Off Time defines the overall time
lapse between the moment the TC client sends the actual Section
state and the moment this section is physically turned off and the
product is stopped from being applied.

The working set may support this DDE as an optional feature to


provide the possibility to store the time settings direct on the device to
make the settings available after a power cycle. Therefore this DDE
needs always to be settable by the TC and shall not be used to
change any working set system behavior.

The DDI shall support the On Change trigger so that the TC is able to
get informed when the value gets changed by the Working Set
Master. The TC shall activate this trigger when using the DDI.
Comment This value should be provided by the implement manufacturer if
applicable and otherwise only DDI 206 "SC Setpoint Turn Off Time"
shall be provided. If the system does not define SC Actual Turn Off
Time and SC Setpoint Turn Off Time separately, it implies that "SC
Setpoint Turn Off Time" may be considered for drawing Actual
Coverage. If "SC Actual Turn Off Time" is defined as 0, the coverage
OFF shall be immediate.
The usage of " SC Actual Turn Off Time" does not eliminate usage of
"SC Setpoint Turn Off time - DDI 206", it is supporting information for
better coverage Map based on Actual CWS. See also DDI 205
including attachment and DDI 206 and 656
Typically used by Device 1 - Tractor
Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Rajashri Munot
Submit Date 2021-10-14
Submit Company John Deere
Revision Number 1
Current Status Published
Status Date 2022-01-10
Status Comments First version

DD Entity 658 - Actual CO2 equivalent specified as mass per area


Definition Actual CO2 equivalent specified as mass per area
Comment For more details see also ISO-14040 and ISO-14044 documents.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 526/572

Typically used by Device 1 - Tractor


Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
25 - Slurry Applicators
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 527/572

DD Entity 659 - Actual CO2 equivalent specified as mass per time


Definition Actual CO2 equivalent specified as mass per time
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

DD Entity 660 - Actual CO2 equivalent specified as mass per mass


Definition Actual CO2 equivalent specified as mass per mass (application rate)
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2022-11-15

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 528/572

Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 529/572

DD Entity 661 - Actual CO2 equivalent specified as mass per yield


Definition Actual CO2 equivalent specified as mass per yield mass
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
9 - Forage harvester
19 - Timber Harvesters
Unit Symbol mg/kg - Mass per mass unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

DD Entity 662 - Actual CO2 equivalent specified as mass per volume


Definition Actual CO2 equivalent specified as mass per volume
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Unit Symbol mg/l - Mass per capacity unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 530/572

DD Entity 663 - Actual CO2 equivalent specified as mass per count


Definition Actual CO2 equivalent specified as mass per count
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
7 - Harvesters
8 - Root Harvester
19 - Timber Harvesters
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

DD Entity 664 - Total CO2 equivalent


Definition Accumulated CO2 equivalent specified as mass in kilogram [kg]
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 531/572

Submit Company GRIMME Landmaschinenfabrik GmbH & Co. KG


Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 532/572

DD Entity 665 - Lifetime total CO2 equivalent


Definition Entire Lifetime CO2 equivalent specified as mass in kilogram [kg]
Comment For more details see also ISO-14040 and ISO-14044 documents.
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2022-10-20
Submit Company GRIMME Landmaschinenfabrik GmbH & Co. KG
Revision Number 1
Current Status Published
Status Date 2022-11-15
Status Comments

DD Entity 666 - Working Direction


Definition This DDI defines the intended Working Direction in the field and also
defines the numbering of the Bouts.
Comment The Working Direction defines the intended Working Direction in the
field and also defines the numbering of the Bouts. If the Working
Direction is 1 (working from left to right, compared to AB-reference
line) the numbering of the Bouts is also from left to right in ascending
order. If the Working Direction is 2 (working from right to left,
compared to AB-reference line) the numbering of the Bouts is from
right to left in ascending order.
For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol not defined - not defined
Resolution 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 533/572

SAE SPN
CANBus Range 0-2
Display Range 0-2
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 534/572

DD Entity 667 - Distance between Guidance Track Number 0R and 1


Definition This DDI defines the distance between tracks 0R and 1.
Comment If the user wants to start with a different Working Width than 100%,
the Track Number 0 has to be divided in two separate Tracks 0R and
0L. Therefore, the Tracks 0R and 0L are deviated from the original
Track 0. To calculate the correct positions of these Tracks, the
distance d0R/1 between Track 0R and 1 and the distance d0R/0L
between 0R and 0L have to be defined.
For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

DD Entity 668 - Distance between Guidance Track Number 0R and 0L


Definition This DDI defines the distance between tracks 0R and 0L.
Comment If the user wants to start with a different Working Width than 100%,
the Track Number 0 has to be divided in two separate Tracks 0R and
0L. Therefore, the Tracks 0R and 0L are deviated from the original
Track 0. To calculate the correct positions of these Tracks, the
distance d0R/1 between Track 0R and 1 and the distance d0R/0L
between 0R and 0L have to be defined.
For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 535/572

DD Entity 669 - Bout Track Number Shift


Definition This DDI defines the amount of tramlines the Tramline pattern is to be
shifted.
Comment The implement may have the possibility to give a Bout Track Number
Shift in its calculation to shift the Tramline pattern. In that case the
Tramline calculation is based on the following formula:
Bout Track Number = Guidance Track Number + 1 + Bout Track
Number Shift.
The Task Controller shall store Bout track number shift in conjunction
with the Unique A-B Guidance Reference Line ID. The TC shall send
this value on change of Unique A-B Guidance Reference Line ID to
inform the implement that it needs to take this Bout Track Number
Shift into account. Therefore, this DDI should be settable.
The Guidance Track Numbers are not influenced by this DDI. A
positive Bout Track Number Shift will shift the Tramline pattern in the
direction of the lower Guidance Track Numbers. A negative Bout
Track Number Shift will shift the Tramline pattern in the direction of
the higher Guidance Track Numbers.
For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol not defined - not defined
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

DD Entity 670 - Tramline Crop protection/fertilization Working Width


Definition Working Width of the Crop protection/fertilization vehicle which will
drive on the tramline tracks.
Comment Working Width of the Crop protection/fertilization vehicle. This is also
the distance between the single Tramline Tracks. This value is a
manual user input and is provided by the Implement to the Task
Controller.
For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 536/572

CANBus Range 0 - 2147483647


Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 537/572

DD Entity 671 - Tramline Tire Width


Definition Width of the largest tire which should fit on the Tramline Track.
Comment This is the Width of the largest tire which should fit on the Tramline
Track. The distance between the rows besides the Tramline Track
shall be wider than the Tire Width to avoid crop damage.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

DD Entity 672 - Tramline Wheel Distance


Definition Distance between the centres of the Wheels of the Crop
protection/fertilization vehicle.
Comment For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 538/572

DD Entity 673 - Tramline Irrigation Working Width


Definition The Working Width of the Irrigation system is the Distance between
the single Tramline Tracks for the Irrigation system.
Comment Besides a Tramlining rhythm for a Sprayer, a second Tramlining
rhythm with a different pattern for an irrigation system may exist.
The Working Width of the Irrigation system is also the Distance
between the single Tramline Tracks for the Irrigation system. This
value is a manual user input and is provided by the Implement to the
Tramline Controller.
The following picture shows an example with a 6m Seed drill Width,
24m Sprayer Width and a 66m Irrigation Width.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

DD Entity 674 - Tramline Irrigation Tire Width


Definition Width of the largest tire which should fit on the Tramline Track.
Comment This is the Width of the largest Tire which should fit on the Tramline
Track. The distance between the rows besides the Tramline Track
shall be wider than the Irrigation Tire Width to avoid crop damage.
For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 539/572

DD Entity 675 - Tramline Irrigation Wheel Distance


Definition Distance between the centre of the Wheels of the Irrigation system.
Comment For more details see attachment DDI 505.
Typically used by Device 4 - Planters /Seeders
Class(es)
Unit Symbol mm - Length
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Karsten Helweg
Submit Date 2015-12-10
Submit Company Competence Center ISOBUS e.V.
Revision Number 1
Current Status Published
Status Date 2022-12-02
Status Comments

DD Entity 676 - Last Bale Binding Mesh Layers


Definition Binding mesh layers in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2023-03-23
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2023-04-27
Status Comments New added

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 540/572

DD Entity 677 - Last Bale Binding Film Layers


Definition Binding film layers in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2023-03-23
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2023-04-27
Status Comments New added

DD Entity 678 - Last Bale Binding Twine Layers


Definition Binding twine layers in the most recently produced bale
Comment The recommended use of this DDE is for a baler to report this once
for every bale that is produced. A baler may add this to its default set
of data, based on an internal on-change data trigger that causes the
baler to report the value of this DDE after the bale is produced. The
recommendation for data logging is that all "Last Bale" DDEs that are
supported by a device are reported together at the moment that the
bale is produced and leaves the machine.
Typically used by Device 7 - Harvesters
Class(es) 9 - Forage harvester
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Mike Schmidt on behalf of Steffen Hoffmann
Submit Date 2023-04-28
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2023-05-02
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 541/572

DD Entity 679 - Crop Contamination Total Mass


Definition Accumulated mass of contamination in yield by dirt or foreign material
as a total counter
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

DD Entity 680 - Crop Contamination Lifetime Total Mass


Definition Accumulated mass of contamination in yield by dirt or foreign material
as a lifetime counter
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol kg - Mass
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 542/572

DD Entity 681 - Film bale Total Count


Definition The total number of foil or film bound product units for which foil or
film binding method was used during operation.
Comment Foil or Film Total Count can be used as total counter of a device
element. It is intended to be used as task based and therefore it is
recommended to support the on-time and on-change trigger methods.
The total trigger method and the settable property are required for
this DDE.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Indra Tjalma
Submit Date 2023-03-27
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

DD Entity 682 - Mesh bale Total Count


Definition The total number of mesh bound product units for which mesh
binding method was used during operation.
Comment Mesh Total Count can be used as total counter of a device element. It
is intended to be used as task based and therefore it is
recommended to support the on-time and on-change trigger methods.
The total trigger method and the settable property are required for
this DDE.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Indra Tjalma
Submit Date 2023-03-27
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 543/572

DD Entity 683 - Twine bale Total Count


Definition The total number of twine bound product units for which twine binding
method was used during operation.
Comment Twine Total Count can be used as total counter of a device element.
It is intended to be used as task based and therefore it is
recommended to support the on-time and on-change trigger methods.
The total trigger method and the settable property are required for
this DDE.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Indra Tjalma
Submit Date 2023-03-27
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

DD Entity 684 - Wrapping Film bale Total Count


Definition The total number of wrapping units for which wrapping film binding
method was used during operation.
Comment Wrapping Film Total Count can be used as total counter of a device
element. It is intended to be used as task based and therefore it is
recommended to support the on-time and on-change trigger methods.
The total trigger method and the settable property are required for
this DDE.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Indra Tjalma
Submit Date 2023-03-27
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 544/572

DD Entity 685 - Lifetime Film Bale Total Count


Definition Total number of film or foil bound product units for which film or foil
binding method was used during operation, of a device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore, this DDE shall
not be settable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE, but shall
not support the settable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range - 2147483647
Submit by Indra Tjalma
Submit Date 2023-03-27
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

DD Entity 686 - Lifetime Mesh Bale Total Count


Definition Total number of mesh bound product units for which mesh binding
method was used during operation, of a device lifetime
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore, this DDE shall
not be settable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE, but shall
not support the settable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range - 2147483647
Submit by Indra Tjalma

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 545/572

Submit Date 2023-03-27


Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 546/572

DD Entity 687 - Lifetime Twine Bale Total Count


Definition Total number of twine bound product units for which Twine binding
method was used during operation, of a device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore, this DDE shall
not be settable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE, but shall
not support the settable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range - 2147483647
Submit by Indra Tjalma
Submit Date 2023-03-27
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

DD Entity 688 - Lifetime Wrapping Film Bale Total Count


Definition Total number of wrapping units for which wrapping film binding
method was used during operation, of a device lifetime.
Comment This is the overall total of the device. This total does not refer to an
application controlled by a Task Controller. Therefore, this DDE shall
not be settable within the device description and neither shall the
device reset the value when the task status changed. It is up to the
device control system when to reset this value. The Working Set
Master shall support the total trigger method for this DDE, but shall
not support the settable property. The Task Controller can request
and store this DDE at the end of a task. But it shall not set this DDE
when the task is resumed.
Typically used by Device 9 - Forage harvester
Class(es)
Unit Symbol # - Quantity/Count
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range - 2147483647
Submit by Indra Tjalma

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 547/572

Submit Date 2023-03-27


Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status New Request Submitted
Status Date 2023-03-27
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 548/572

DD Entity 689 - Effective Total Electrical Battery Energy Consumption


Definition Accumulated total electrical battery energy consumption in working
position.
Comment
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol kWh - Electrical energy
Resolution 0,001
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483,648 - 2147483,647
Submit by Johannes Nägele
Submit Date 2023-12-04
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2024-02-19
Status Comments

DD Entity 690 - Ineffective Total Electrical Battery Energy Consumption


Definition Accumulated total electrical battery energy consumption in non
working position.
Comment Energy throughput of the battery including secondary consumers like
DC/DC converter, AC compressor...
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol kWh - Electrical energy
Resolution 0,001
SAE SPN

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 549/572

CANBus Range -2147483648 - 2147483647


Display Range -2147483,648 - 2147483,647
Submit by Johannes Nägele
Submit Date 2023-12-04
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2024-02-19
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 550/572

DD Entity 691 - Instantaneous Electrical Battery Energy Consumption per


Time
Definition Electrical battery energy consumption per time
Comment Energy throughput of the battery including secondary consumers like
DC/DC converter, AC compressor...
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol W - Electrical Power
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Johannes Nägele
Submit Date 2023-12-04
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2024-02-19
Status Comments

DD Entity 692 - Instantaneous Electrical Battery Energy Consumption per


Area
Definition Electrical battery energy consumption per area
Comment Energy throughput of the battery including secondary consumers like
DC/DC converter, AC compressor...
Typically used by Device 1 - Tractor
Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Unit Symbol kWh/m² - Electrical energy per area
Resolution 0,00001

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 551/572

SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -21474,83648 - 21474,836470000002
Submit by Johannes Nägele
Submit Date 2023-12-04
Submit Company AGCO
Revision Number 1
Current Status Published
Status Date 2024-02-19
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 552/572

DD Entity 32768 - Maximum Droplet Size


Definition Definition:
The maximum droplet size the system can produce. Defined as:
0 = Unknown,
1 = Extremely Fine - XF,
2 = Very Fine - VF,
3 = Fine - F,
4 = Medium - M,
5 = Coarse - C,
6 = Very Coarse - VC,
7 = Extremely Coarse - XC,
8 = Ultra Coarse - UC,
9-254 = Reserved,
255 = No Droplet Size Available.
Comment Droplet sizes are currently defined in ISO 25358 and are broken into
8 classification categories and also assigned a corresponding colour
code as follows: Extremely Fine = Purple, Very Fine = Red, Fine =
Orange, Medium = Yellow, Coarse = Green, Very Coarse = Blue,
Extremely Coarse = White, Ultra Coarse = Black
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 255
Display Range 0 - 255
Submit by John Summers
Submit Date 2021-03-08
Submit Company TeeJet Technologies
Revision Number 1
Current Status Published
Status Date 2021-05-12
Status Comments

DD Entity 32769 - Maximum Crop Grade Diameter


Definition Maximum crop diameter in mm, measured with crop specific methods
Comment The diameter of the crop to indicate its grade. An example of the
application of this DDI is grading root crops such as potatoes and
onions.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 553/572

Unit Symbol mm - Length


Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 554/572

DD Entity 32770 - Maximum Crop Grade Length


Definition Maximum crop length in mm, measured with crop specific methods
Comment The length of the crop to indicate its grade.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

DD Entity 32771 - Maximum Crop Contamination Mass per Area


Definition Maximum absolut mass of contamination in yield by dirt or foreign
material per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 555/572

DD Entity 32772 - Maximum Crop Contamination Mass per Time


Definition Maximum mass of contamination in yield by dirt or foreign material
per time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

DD Entity 36864 - Minimum Droplet Size


Definition The minimum droplet size the system can produce. Defined as:
0 = Unknown,
1 = Extremely Fine - XF,
2 = Very Fine - VF,
3 = Fine - F,
4 = Medium - M,
5 = Coarse - C,
6 = Very Coarse - VC,
7 = Extremely Coarse - XC,
8 = Ultra Coarse - UC,
9-254 = Reserved,
255 = No Droplet Size Available.
Comment Droplet sizes are currently defined in ISO 25358 and are broken into
8 classification categories and also assigned a corresponding colour
code as follows:
Extremely Fine = Purple,
Very Fine = Red,
Fine = Orange,
Medium = Yellow,
Coarse = Green,
Very Coarse = Blue,
Extremely Coarse = White,
Ultra Coarse = Black

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 556/572

Typically used by Device 4 - Planters /Seeders


Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 255
Display Range 0 - 255
Submit by John Summers
Submit Date 2021-03-08
Submit Company TeeJet Technologies
Revision Number 1
Current Status Published
Status Date 2021-05-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 557/572

DD Entity 36865 - Minimum Crop Grade Diameter


Definition Minimum crop diameter in mm, measured with crop specific methods
Comment The diameter of the crop to indicate its grade. An example of the
application of this DDI is grading root crops such as potatoes and
onions.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

DD Entity 36866 - Minimum Crop Grade Length


Definition Minimum crop length in mm, measured with crop specific methods
Comment The length of the crop to indicate its grade.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 558/572

DD Entity 36867 - Minimum Crop Contamination Mass per Area


Definition Minimum absolut mass of contamination in yield by dirt or foreign
material per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

DD Entity 36868 - Minimum Crop Contamination Mass per Time


Definition Minimum mass of contamination in yield by dirt or foreign material per
time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 559/572

DD Entity 40960 - Default Droplet Size


Definition The default droplet size the system is producing. Defined as:
0 = Unknown,
1 = Extremely Fine - XF,
2 = Very Fine - VF,
3 = Fine - F,
4 = Medium - M,
5 = Coarse - C,
6 = Very Coarse - VC,
7 = Extremely Coarse - XC,
8 = Ultra Coarse - UC,
9-254 = Reserved,
255 = No Droplet Size Available.
Comment Droplet sizes are currently defined in ISO 25358 and are broken into
8 classification categories and also assigned a corresponding colour
code as follows:
Extremely Fine = Purple,
Very Fine = Red,
Fine = Orange,
Medium = Yellow,
Coarse = Green,
Very Coarse = Blue,
Extremely Coarse = White,
Ultra Coarse = Black
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 255
Display Range 0 - 255
Submit by John Summers
Submit Date 2021-05-12
Submit Company TeeJet Technologies
Revision Number 1
Current Status Published
Status Date 2021-05-12
Status Comments

DD Entity 40961 - Default Crop Grade Diameter


Definition Default crop diameter in mm, measured with crop specific methods
Comment The diameter of the crop to indicate its grade. An example of the
application of this DDI is grading root crops such as potatoes and
onions.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 560/572

Typically used by Device 4 - Planters /Seeders


Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 561/572

DD Entity 40962 - Default Crop Grade Length


Definition Default crop length in mm, measured with crop specific methods
Comment The length of the crop to indicate its grade.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

DD Entity 40963 - Default Crop Contamination Mass per Area


Definition Default absolut mass of contamination in yield by dirt or foreign
material per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 562/572

DD Entity 40964 - Default Crop Contamination Mass per Time


Definition Default mass of contamination in yield by dirt or foreign material per
time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

DD Entity 45056 - Actual Droplet Size


Definition The actual droplet size the system is producing. Defined as:
0 = Unknown,
1 = Extremely Fine - XF,
2 = Very Fine - VF,
3 = Fine - F,
4 = Medium - M,
5 = Coarse - C,
6 = Very Coarse - VC,
7 = Extremely Coarse - XC,
8 = Ultra Coarse - UC,
9-254 = Reserved,
255 = No Droplet Size Available.
Comment Droplet sizes are currently defined in ISO 25358 and are broken into
8 classification categories and also assigned a corresponding colour
code as follows:
Extremely Fine = Purple,
Very Fine = Red,
Fine = Orange,
Medium = Yellow,
Coarse = Green,
Very Coarse = Blue,
Extremely Coarse = White,
Ultra Coarse = Black

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 563/572

Typically used by Device 4 - Planters /Seeders


Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 255
Display Range 0 - 255
Submit by John Summers
Submit Date 2021-03-08
Submit Company TeeJet Technologies
Revision Number 1
Current Status Published
Status Date 2021-05-12
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 564/572

DD Entity 45057 - Actual Crop Grade Diameter


Definition Actual crop diameter in mm, measured with crop specific methods
Comment The diameter of the crop to indicate its grade. An example of the
application of this DDI is grading root crops such as potatoes and
onions.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

DD Entity 45058 - Actual Crop Grade Length


Definition Actual crop length in mm, measured with crop specific methods
Comment The length of the crop to indicate its grade.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 565/572

DD Entity 45059 - Actual Crop Contamination Mass per Area


Definition Absolut mass of contamination in yield by dirt or foreign material per
area, see also DDI 100.

Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

DD Entity 45060 - Actual Crop Contamination Mass per Time


Definition Absolut mass of contamination in yield by dirt or foreign material per
time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 566/572

DD Entity 49152 - Setpoint Droplet Size


Definition The setpoint for droplet size. Defined as:
0 = Unknown,
1 = Extremely Fine - XF,
2 = Very Fine - VF,
3 = Fine - F,
4 = Medium - M,
5 = Coarse - C,
6 = Very Coarse - VC,
7 = Extremely Coarse - XC,
8 = Ultra Coarse - UC,
9-254 = Reserved,
255 = No Droplet Size Available.
Comment Droplet sizes are currently defined in ISO 25358 and are broken into
8 classification categories and also assigned a corresponding colour
code as follows:
Extremely Fine = Purple,
Very Fine = Red,
Fine = Orange,
Medium = Yellow,
Coarse = Green,
Very Coarse = Blue,
Extremely Coarse = White,
Ultra Coarse = Black
Typically used by Device 4 - Planters /Seeders
Class(es) 5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range 0 - 255
Display Range 0 - 255
Submit by John Summers
Submit Date 2021-03-08
Submit Company TeeJet Technologies
Revision Number 1
Current Status ISO-Published
Status Date 2021-05-12
Status Comments Status was published

DD Entity 49153 - Setpoint Crop Grade Diameter


Definition Setpoint crop diameter in mm, measured with crop specific methods
Comment The diameter of the crop to indicate its grade. An example of the
application of this DDI is grading root crops such as potatoes and
onions.

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 567/572

Typically used by Device 4 - Planters /Seeders


Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 568/572

DD Entity 49154 - Setpoint Crop Grade Length


Definition Setpoint crop length in mm, measured with crop specific methods
Comment The length of the crop to indicate its grade.
Typically used by Device 4 - Planters /Seeders
Class(es) 7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Unit Symbol mm - Length
Resolution 0,001
SAE SPN
CANBus Range 0 - 2147483647
Display Range 0 - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-03-24
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-15
Status Comments

DD Entity 49155 - Setpoint Crop Contamination Mass per Area


Definition Setpoint of the absolut mass of contamination in yield by dirt or
foreign material per area
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/m² - Mass per area unit
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 569/572

DD Entity 49156 - Setpoint Crop Contamination Mass per Time


Definition Setpoint of the mass of contamination in yield by dirt or foreign
material per time
Comment
Typically used by Device 7 - Harvesters
Class(es) 8 - Root Harvester
Unit Symbol mg/s - Mass flow
Resolution 1
SAE SPN
CANBus Range 0 - 2147483647
Display Range - 2147483647
Submit by Hendrik Hageböke
Submit Date 2023-05-02
Submit Company GRIMME Landmaschinen GmbH & Co.KG
Revision Number 1
Current Status Published
Status Date 2023-05-31
Status Comments

DD Entity 57342 - PGN Based Data


Definition This DDI is used in the XML files to identify PGN based data.
Comment This DDI is specified in ISO 11783-10 IS paragraph 6.3 Logging
parameters from parameter groups.
Typically used by Device 0 - Non-specific system
Class(es) 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Unit Symbol n.a. -
Resolution 1
SAE SPN
CANBus Range -2147483648 - 2147483647
Display Range -2147483648 - 2147483647
Submit by Part 10 Task Force
Submit Date 2005-01-25
Submit Company 0 - Reserved

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 570/572

Revision Number 1
Current Status ISO-Approved
Status Date 2009-02-05
Status Comments Added to the on-line database

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 571/572

DD Entity 57343 - Request Default Process Data


Definition Request Default Process Data. This DDE is the highest ISO assigned
entity. The range above this number is reserved for manufacture
specific DDE's.
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol n.a. -
Resolution 1
SAE SPN not specified
CANBus Range 0-0
Display Range 0-0
Submit by 11783-Part 10 Task Force
Submit Date 2005-01-20
Submit Company 89 - Kverneland Group, Electronics Division
Revision Number 1
Current Status Published
Status Date 2023-07-10
Status Comments Comment "This DDE was a result of March 2005 TF10 meeting."
removed

DD Entity 57344 - 65534 Proprietary DDI Range


Definition Manufacturer proprietary definitions
Comment It is not recommended to process proprietary DDEs from other
manufacturers
Typically used by Device - Not Assigned
Class(es)
Unit Symbol n.a. -
Resolution 0
SAE SPN
CANBus Range -
Display Range -
Submit by Part 10 Task Force
Submit Date 0000-00-00
Submit Company 0 - Reserved
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.
2024-03-10 ISOBUS Data Dictionary Page 572/572

DD Entity 65535 - Reserved


Definition Reserved
Comment
Typically used by Device - Not Assigned
Class(es)
Unit Symbol n.a. -
Resolution 0
SAE SPN
CANBus Range -
Display Range -
Submit by Part 10 Task Force
Submit Date 0000-00-00
Submit Company 0 - Reserved
Revision Number 1

@ Copyright International Organization for Standardization, see: www.iso.org/iso/copyright.htm.


No reproduction on networking permitted without license from ISO. The export file from the online data base is supplied without liability.
Hard and Saved copies of this document are considered uncontrolled and represents a snap-shot of the ISO11783-11 online data base.

You might also like