TDK Lambda
TDK Lambda
G Series
Programmable DC Power Supplies
Full-Rack 1kW/1.7kW/2.7kW/3.4kW/5kW/7.5kW in 1U Height
GSP 10kW/15kW in 2U/3U Height
Applications
™ power supplies have been designed to meet the demands of a wide variety of applications.
Test & Measurement systems, Component Device Testing, Manufacturing and process control.
Semiconductor Processing & Burn-In, Aerospace & Satellite Testing, Medical Imaging, Green Technology.
Higher power systems can be configured with up to twelve (12) 7.5kW units. Each unit is 1U with zero space
between them (zero stack).
OEM Designers have a wide variety of Inputs and Outputs from which to select depending on application
and location.
3
G1kW-7.5kW Front Panel Description
4
3 3
2
1
5 6
11
9
10
12
1 2 3 4 5 6 7 8
1. Isolated Analog Programming, Monitoring and other control connector (DB26 Female)
2. USB Interface connector (Type B).
3. RS-232/RS-485 IN/OUT Remote Digital Interface (RJ-45 type) for Multi-Drop connection
4. LAN ( 1.5) Interface connector (RJ-45 type with LAN status indicators).
5. Auto paralleling Bus connectors (mini I/O type) for connecting Master Unit-to-Slave and Slave Unit-to-Slave unit.
6. Remote/Local Output Voltage Sense Connections (spring cage).
7. Output Connections: Rugged busbars (shown) for models up to and including 100V Output;
Plug connector: PHOENIX CONTACT IPC 5/4-STF-7.62 for models with Outputs >100V.
8. G2.7kW / G3.4kW / G5kW AC Input: 208VAC, 400VAC & 480VAC, Three Phase, 50/60 Hz. (Model shown)
AC Input Plug Connector: PHOENIX CONTACT Power Combicon PC 5/4-STCL1-7.62 Series with strain relief.
G1.7kW / G2.7kW / G3.4kW AC Input Single Phase, 50/60 Hz.
AC Input Plug Connector: PHOENIX CONTACT Power Combicon PC 5/3-STCL1-7.62 Series with strain relief.
G1kW AC Input Connector: IEC320 C16.
9. Optional Interface Position for IEEE 488.2 SCPI or AnyBus Interface.
10. Exhaust air assures reliable operation when units are zero stacked.
11. Functional Ground connection (M4x8mm stud).
12. Reset button. Set default Power Supply settings.
13. G+ 5kW 1000V and 1.500V has the same housing as 7.5kW
4
G7.5kW Rear Panel Description
9 11
10
12
1 2 3 4 5 6 7 8
1. Isolated Analog Programming, Monitoring and other control connector (DB26 Female)
2. USB Interface connector (Type B).
3. RS-232/RS-485 IN/OUT Remote Digital Interface (RJ-45 type) for Multi-Drop connection
4. LAN ( 1.5) Interface connector (RJ-45 type with LAN status indicators).
5. Auto paralleling Bus connectors (mini I/O type) for connecting Master Unit-to-Slave and Slave Unit-to-Slave unit.
6. Remote/Local Output Voltage Sense Connections.
Plug connector: PHOENIX CONTACT - GIC 2,5 HCV/ 3-ST-7,62 - 1745632
7. Output Connections: Rugged busbars (shown) for models up to and including 1500V Output;
8. G7.5kW: AC Input: 480VAC, Three Phase, 50/60 Hz. (Model shown)
AC Input Plug Connector: PHOENIX CONTACT Power Combicon PC 5/4-STCL1-7.62 Series with strain relief.
AC Input: 208VAC, Three Phase, 50/60 Hz.
AC Input Plug Connector: PHOENIX CONTACT DFK-IPC 16/4-STF-10.16 with strain relief.
9. Optional Interface Position for IEEE 488.2 SCPI or AnyBus Interface.
10. Exhaust air assures reliable operation when units are zero stacked.
11. Functional Ground connection (M4x8mm stud).
12. Reset button. Set default Power Supply settings.
5
GSP10kW Front Panel Description
3 4 3
2
1 5 6
9 11
10
12
1 2 3 4 5 6 7 8
1. Isolated Analog Programming, Monitoring and other control connector (DB26 Female)
2. USB Interface connector (Type B).
3. RS-232/RS-485 IN/OUT Remote Digital Interface (RJ-45 type) for Multi-Drop connection
4. LAN ( 1.5) Interface connector (RJ-45 type with LAN status indicators).
5. Auto paralleling Bus connectors (mini I/O type) for connecting Master unit-to-Slave and Slave unit-to-Slave unit.
6. Remote/Local Output Voltage Sense Connections (spring cage).
7. Output Connections: Rugged busbars (shown) for models up to and including 100V Output;
Plug connector: PHOENIX CONTACT DFK-IPC 16/4-STF-10.16 for models with Outputs >100V.
8. Input: 208VAC, 400VAC & 480VAC Three Phase, 50/60 Hz.
AC Input Plug Connector: PHOENIX CONTACT DFK-IPC 16/4-STF-10.16 with strain relief.
9. Optional Interface Position for IEEE 488.2 SCPI or AnyBus Interface.
10. Exhaust air assures reliable operation when zero stacked.
11. Functional Ground connection (M4x8mm stud).
12. Reset button. Set default Power Supply settings.
6
GSP15kW Front Panel Description
3 4 3
2
1
5 6
12
10
1 2 3 4 5 6
7
1. Isolated Analog Programming, Monitoring and other control connector (DB26 Female)
2. USB Interface connector (Type B).
3. RS-232/RS-485 IN/OUT Remote Digital Interface (RJ-45 type) for Multi-Drop connection
4. LAN ( 1.5) Interface connector (RJ-45 type with LAN status indicators).
5. Auto paralleling Bus connectors (mini I/O type) for connecting Master unit-to-Slave and Slave unit-to-Slave unit.
6. Remote/Local Output Voltage Sense Connections (spring cage).
7. Output Connections: Rugged busbars for models up to and including 100V Output;
Plug connector: PHOENIX CONTACT DFK-IPC 16/4-STF-10.16 for models with Outputs >100V (shown).
8. Input: 208VAC, 400VAC & 480VAC Three Phase, 50/60 Hz.
AC Input Plug Connector: PHOENIX CONTACT DFK-PC 16/4-ST-10.16 with strain relief.
9. Optional Interface Position for IEEE 488.2 SCPI or AnyBus Interface.
10. Exhaust air assures reliable operation when zero stacked.
11. Functional Ground connection (M4x8mm stud).
12. Reset button. Set default Power Supply settings.
7
Front Panel Display MENU/CONTROL buttons:
Voltage Current
Encoder Encoder
(Clickable) (Clickable)
8
™ G&GSP Series
OUT (LED)
Blank Front Panel (ATE version) POWER (LED) REM (LED)
2
1 3
A Blank Front Panel is available for applications where the front panel display and controls are not required and
only remote interface (Digital/Analog) is needed.
The Blank Front Panel option has all the standard product functions and features except the display.
The power supply can be controlled via the rear panel Remote digital interface
(LAN, USB, RS-232/RS-485) or via the remote Isolated Analog interface.
RS-485 Link
RS-485 Link
9
Graphical User Interface
Advanced "Virtual Control Panel" allows programming and monitoring unit(s) with or without front panel display.
1. 1. Control and monitor DC Programmable Power Supply Series (GENESYS+, GENESYS and Z+).
2. 2. Automatically detect power supplies connected to a PC and/or local network.
3. 3. Advanced Terminal, including Modbus-TCP and EtherCAT communication interfaces.
4. 4. Real-time Graph and Waveform creator, including pre-built functions i.e. Sine, Triangle and Square.
5. 5. Solar array simulation based on VOC, VMP, IMP, ISC.
6. 6. Advanced functions control – Slew-Rate, Internal Resistance and Constant Power.
7. 7. Multi-Model Monitoring and Control Panel.
8. 8. Individual and Global commands control.
10
How to order G1kW/1.7kW - Power Supply Identification / Accessories
G 10 - 170 - - -
Series Name Output Output Interface Options AC Cord Options Accessories Options
only for 1kW
Front Panel Type Voltage Current Region: E - Europe M - Printed *User Manual
Empty: standard (0~10V) (0~170A) * User Manual & GUI are
U - North America
available on the website
B: Blank Front Panel (ATE version) J - Japan P - Bus Parralleling Cable
C - China
AC Inputs (All Models) I - Middle East
1Ø, 85 ~ 265Vac
Interface Options (Factory installed) P/N
LAN ( 1.5 compliant with Multi-Drop capability)- built-in -
USB 2.0 compliant with Multi-Drop capability - built-in -
RS-232/RS-485 - built-in -
Isolated Analog Program/Monitor Interface
-
(5V/10V Pgm/Mon with 600V isolation) - built-in
IEEE (488.2 & SCPI compliant with Multi-Drop capability installed) IEEE
Modbus-TCP MDBS
EtherCAT ECAT
Isolated Analog Current Program/Monitor Interface IS420
(4mA-20mA with 600V isolation)
Models 1kW
Model Voltage (V) Current (A) Power (W) Model Voltage (V) Current (A) Power (W)
G10-100 0~10V 0~100 1000 G80-12.5 0~80V 0~12.5 1000
G20-50 0~20V 0~50 1000 G100-10 0~100V 0~10 1000
G30-34 0~30V 0~34 1020 G150-7 0~150V 0~7 1050
G40-25 0~40V 0~25 1000 G300-3.5 0~300V 0~3.5 1050
G60-17 0~60V 0~17 1020 G600-1.7 0~600V 0~1.7 1020
Models 1.7kW
Model Voltage (V) Current (A) Power (W) Model Voltage (V) Current (A) Power (W)
G10-170 0~10V 0~170 1700 G80-21 0~80V 0~21 1680
G20-85 0~20V 0~85 1700 G100-17 0~100V 0~17 1700
G30-56 0~30V 0~56 1680 G150-11.2 0~150V 0~11.2 1680
G40-42 0~40V 0~42 1680 G300-5.6 0~300V 0~5.6 1680
G60-28 0~60V 0~28 1680 G600-2.8 0~600V 0~2.8 1680
Accessories
Accessories will be sent separately from the Power Supply packing, according to order.
1. Serial Communication cable. RS-232/RS-485 cable is used to connect the power supply to the Host PC.
Mode RS-485 RS-232
PC Connector, Communication Cable, Power Supply Connector DB-9F. Shielded L=2m. RJ-45 DB-9F. Shielded L=2m, RJ-45
P/N GEN/485-9 GEN/232-9
2. Serial link cable (Included with the power supply)
Daisy-chain up to 31 ™ power supplies.
Mode Power Supply Connector Communication Cable P/N
RS-485 RJ-45 Shielded L=50cm GEN/RJ45
11
How to order G2.7kW / 3.4kW - Power Supply Identification / Accessories
G 10 - 340 - - -
Series Name Output Output Interface Options AC Input Options Accessories Options
Front Panel Type Voltage Current 1P208 (Single Phase 170~265VAC) M - Printed *User Manual
Empty: standard (0~10V) (0~340A) 3P208 (Three Phase 170~265VAC) * User Manual & GUI are
available on the website
B: Blank Front Panel (ATE version) 3P400 (Three Phase 342~460VAC)
3P480 (Three Phase 342~528VAC) P - Bus Parralleling Cable
Models G2.7kW
Model Output Output Output Model Output Output Output
Voltage VDC Current (A) Power (W) Voltage VDC Current (A) Power (W)
G10-265 0~10V 0~265 2650 G80-34 0~80V 0~34 2720
G20-135 0~20V 0~135 2700 G100-27 0~100V 0~27 2700
G30-90 0~30V 0~90 2700 G150-18 0~150V 0~18 2700
G40-68 0~40V 0~68 2720 G300-9 0~300V 0~9 2700
G60-45 0~60V 0~45 2700 G600-4.5 0~600V 0~4.5 2700
Models G3.4kW
Model Output Output Output Model Output Output Output
Voltage VDC Current (A) Power (W) Voltage VDC Current (A) Power (W)
G10-340 0~10V 0~340 3400 G80-42 0~80V 0~42 3360
G20-170 0~20V 0~170 3400 G100-34 0~100V 0~34 3400
G30-112 0~30V 0~112 3360 G150-22.5 0~150V 0~22.5 3375
G40-85 0~40V 0~85 3400 G300-11.5 0~300V 0~11.5 3450
G60-56 0~60V 0~56 3360 G600-5.6 0~600V 0~5.6 3360
Accessories
Accessories will be sent separately from the Power Supply packing, according to order.
1. Serial Communication cable. RS-232/RS-485 cable is used to connect the power supply to the Host PC.
Mode RS-485 RS-232
PC Connector, Communication Cable, Power Supply Connector DB-9F. Shielded L=2m. RJ-45 DB-9F. Shielded L=2m, RJ-45
P/N GEN/485-9 GEN/232-9
2. Serial link cable (Included with the power supply)
Daisy-chain up to 31 ™ power supplies.
Mode Power Supply Connector Communication Cable P/N
RS-485 RJ-45 Shielded L=50cm GEN/RJ45
3. Bus Paralleling cable
Connectors Cables P/N
2013595-1 (TYCO) Shielded L=11cm G/P
4. User Manual
Printed User Manual G/M
12
How to order G5kW - Power Supply Identification / Accessories
G 10 - 500 - - -
Series Name Output Output Interface Options AC Input Options Accessories Options
Front Panel Type Voltage Current 3P208 (Three Phase 170~265VAC) M - Printed *User Manual
Empty: standard (0~10V) (0~500A) 3P400 (Three Phase 342~460VAC) * User Manual & GUI are
available on the website
B: Blank Front Panel (ATE version) 3P480 (Three Phase 342~528VAC)
P - Bus Parralleling Cable
13
How to order G7.5kW - Power Supply Identification / Accessories
G 20 - 375 - - -
Series Name Output Output Interface Options AC Input Options Accessories Options
Front Panel Type Voltage Current 3P208 (Three Phase 170~265VAC) M - Printed *User Manual
Empty: standard (0~20V) (0~375A) 3P480 (Three Phase 342~528VAC) * User Manual & GUI are
available on the website
B: Blank Front Panel (ATE version)
P - Bus Parralleling Cable
Models 7.5kW
Model Voltage (VDC) Current (A) Power (W) Model Voltage (VDC) Current (A) Power (W)
G20-375 0~20V 0~375 7500 G150-50 0~150V 0~50 7500
G30-250 0~30V 0~250 7500 G200-37.5 0~200V 0~37.5 7500
G40-188 0~40V 0~188 7520 G300-25 0~300V 0~25 7500
G60-125 0~60V 0~125 7500 G600-12.5 0~600V 0~12.5 7500
G80-94 0~80V 0~94 7500 G1000-7.5 0~1000V 0~7.5 7500
G100-75 0~100V 0~75 7500 G1500-5 0~1500V 0~5 7500
Accessories
Accessories will be sent separately from the Power Supply packing, according to order.
1. Serial Communication cable
RS-232/RS-485 cable is used to connect the power supply to the Host PC.
Mode RS-485 RS-232
PC Connector DB-9F DB-9F
Communication Cable Shielded L=2m Shielded L=2m
Power Supply Connector RJ-45 RJ-45
P/N GEN/485-9 GEN/232-9
2. Serial link cable (Included with the power supply)
Daisy-chain up to 31 ™ power supplies.
Mode Power Supply Connector Communication Cable P/N
RS-485 RJ-45 Shielded L=50cm GEN/RJ45
3. Bus Paralleling cable
Connectors Cables P/N
2013595-1 (TYCO) Shielded L=11cm G/P
4. User Manual
Printed User Manual G/M
5. Parallel Kit: 30kW/45kW
G/P-4U: BusBar Parallel Kit for 30 kW operation
G/P-6U: BusBar Parallel Kit for 45 kW operation
14
How to order GSP10kW-15kW - Power Supply Identification / Accessories
G SP 10 - 1500 - - -
Series Name Output Output Interface Options AC Input Options Accessories Options
Front Panel Type Voltage Current 3P208 (Three Phase 170~265VAC) M - Printed *User Manual
Empty: standard (0~10V) (0~1500A) 3P400 (Three Phase 342~460VAC) * User Manual & GUI are
available on the website
B: Blank Front Panel (ATE version) 3P480 (Three Phase 342~528VAC)
15
™ Family Output Voltage and Current
G (Std Front Panel Display) GSP/GBSP
Models Series (Scalable Power)
GB (Blank Front Panel Display)
Rated Power 1kW 1.7kW 2.7kW 3.4kW 5kW 5kW - 7.5kW 10kW 15kW
HV
Voltage Range Current Range (A)
0-10V 0~100A 0~170A 0~265A 0~340A 0~500A - 0~1000A 0~1500A
0-20V 0~50A 0~85A 0~135A 0~170A 0~250A 0~375A 0~500A 0~750A
0-30V 0~34A 0~56A 0~90A 0~112A 0~170A 0~250A 0~340A 0~510A
0-40V 0~25A 0~42A 0~68A 0~85A 0~125A 0~188A 0~250A 0~375A
0-50V - - - - 0~100A - 0~200A 0~300A
0-60V 0~17A 0~28A 0~45A 0~56A 0~85A 0~125A 0~170A 0~255A
0-80V 0~12.5A 0~21A 0~34A 0~42A 0~65A 0~94A 0~130A 0~195A
0-100V 0~10A 0~17A 0~27A 0~34A 0~50A 0~75A 0~100A 0~150A
0-150V 0~7A 0~11.2A 0~18A 0~22.5A 0~34A 0~50A 0~68A 0~102A
0-200V - - - - 0~25A 0~37.5A 0~50A 0~75A
0-300V 0~3.5A 0~5.6A 0~9A 0~11.5A 0~17A 0~25A 0~34A 0~51A
0-400V - - - - 0~13A - 0~26A 0~39A
0-500V - - - - 0~10A - 0~20A 0~30A
0-600V 0~1.7A 0~2.8A 0~4.5A 0~5.6A 0~8.5A 0~12.5A 0~17A 0~25.5A
0-1000V - - - - 0~0.5A 0~7.5A - -
0-1500V - - - - 0~3.4A 0~5A - -
Weight (kg/lb) 5/11 5/11 6.25/14.3 6.25/14.3 7.5/16.5 8.5/18.7 8.5/18.7 15.5/34.2 23.5/51.8
AC Input Range
Rated Power 1kW 1.7kW 2.7kW 3.4kW 5kW 7.5kW 10kW 15kW
1Ø, 85-265Vac * * N/A N/A N/A N/A N/A N/A
1Ø, 170-265Vac * * N/A N/A N/A N/A
3P208 N/A N/A * * * * * *
3P400 N/A N/A * * * N/A * *
3P480 N/A N/A * * * * * *
3P208 (Three Phase 170~265VAC), 3P400 (Three Phase 342~460VAC), 3P480 (Three Phase 342~528VAC)
Models 1kW
Model Voltage (V) Current (A) Power (W) Model Voltage (V) Current (A) Power (W)
GH10-100 0~10V 0~100 1000 GH80-12.5 0~80V 0~12.5 1000
GH20-50 0~20V 0~50 1000 GH100-10 0~100V 0~10 1000
GH30-34 0~30V 0~34 1020 GH150-7 0~150V 0~7 1050
GH40-25 0~40V 0~25 1000 GH300-3.5 0~300V 0~3.5 1050
GH60-17 0~60V 0~17 1020 GH600-1.7 0~600V 0~1.7 1020
Models 1.5kW
Model Voltage (V) Current (A) Power (W) Model Voltage (V) Current (A) Power (W)
GH10-150 0~10V 0~150 1500 GH80-19 0~80V 0~19 1520
GH20-75 0~20V 0~75 1500 GH100-15 0~100V 0~15 1500
GH30-50 0~30V 0~50 1500 GH150-10 0~150V 0~10 1500
GH40-38 0~40V 0~38 1520 GH300-5 0~300V 0~5 1500
GH60-25 0~60V 0~25 1500 GH600-2.6 0~600V 0~2.6 1560
16
™ 1kW SERIES SPECIFICATIONS
OUTPUT RATING G 10-100 20-50 30-34 40-25 60-17 80-12.5 100-10 150-7 300-3.5 600-1.7
1.Rated output voltage(*1) V 10 20 30 40 60 80 100 150 300 600
2.Rated output current (*2) A 100 50 34 25 17 12.5 10 7 3.5 1.7
3.Rated output power W 1000 1000 1020 1000 1020 1000 1000 1050 1050 1020
INPUT CHARACTERISTICS V 10 20 30 40 60 80 100 150 300 600
1.Input voltage/freq. (*3) --- 85~265Vac, continuous, 47~63Hz, Single Phase
2. Maximum Input current at 100% load (100/200) A 12.5/6.5
3.Power Factor (Typ) --- 0.99 @ 100Vac 0.98 @ 200Vac, rated output power.
4.Efficiency at 100 Vac/200Vac, rated output (*17) % 86/88 87/89 87/89 87/89 87/89 87/89 88/90 88/90 88/90 88/90
5.Inrush current (*5) A Less than 50A
CONSTANT VOLTAGE MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*6) --- 0.01% of rated output voltage
2.Max. Load regulation (*7) --- 0.01% of rated output voltage +2mV
3.Ripple and noise (p-p, 20MHz) (*8) mV 50 50 50 60 60 75 75 75 120 500
4.Ripple r.m.s. 5Hz~1MHz (*8) mV 6 6 6 7 7 10 12 9 20 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.01% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 35 35 35 35 35 35 40 50 100 100
Full load (*12) mS 35 30 60 60 60 60 80 120 220 220
10.Down-prog.response time:
No load (*12) mS 500 700 1000 1200 1500 1700 2600 2900 4600 4600
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12.Start up delay Sec Less than 6 Sec
13.Hold-up time mS 20ms typical, rated output power
CONSTANT CURRENT MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*6) --- 0.02% of rated output current. +2mA
2.Max. Load regulation (*9) --- 0.02% of rated output current. +5mA
3.Ripple r.m.s. @ rated voltage. B.W 5Hz~1MHz. (*13) mA ≤420 ≤160 ≤100 ≤60 ≤50 ≤30 ≤20 ≤10 ≤8 ≤5
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift ---
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*14) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*14) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*14) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
8. TRIGGER IN / TRIGGER OUT signals --- Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive
edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
2. Series operation --- Possible. Two identical units. Refer to instruction manual.
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 60 80 100 150 300 600
RS232/485, Optional IEEE (*16) Interfaces)
1.Vout programming accuracy (*15) --- 0.05% of rated output voltage
2.Iout programming accuracy (*14) --- 0.1% of actual output current+0.2% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*14) --- 0.2% of rated output current 0.25% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.002% 0.002% 0.011% 0.007% 0.004% 0.002%
8.Iout readback resolution (of rated output current)) % 0.011% 0.003% 0.004% 0.005% 0.007% 0.009% 0.011% 0.015% 0.004% 0.007`%
17
™ 1.7kW SERIES SPECIFICATIONS
OUTPUT RATING G 10-170 20-85 30-56 40-42 60-28 80-21 100-17 150-11.2 300-5.6 600-2.8
1.Rated output voltage(*1) V 10 20 30 40 60 80 100 150 300 600
2.Rated output current (*2) A 170 85 56 42 28 21 17 11.2 5.6 2.8
3.Rated output power W 1700 1700 1680 1680 1680 1680 1700 1680 1680 1680
INPUT CHARACTERISTICS V 10 20 30 40 60 80 100 150 300 600
1.Input voltage/freq. (*3) --- 85~265Vac, continuous, 47~63Hz,Single Phase
2. Maximum Input current at 100% load (100/200) A 20/10
3.Power Factor (Typ) --- 0.99 @ 100Vac 0.98 @ 200Vac, rated output power.
4.Efficiency at 100 Vac/200Vac, rated output (*19) % 86/88 87/89 87/89 87/89 87/89 87/89 88/90 88/90 88/90 88/90
5.Inrush current (*5) A Less than 50A
CONSTANT VOLTAGE MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*6) --- 0.01% of rated output voltage
2.Max. Load regulation (*7) --- 0.01% of rated output voltage +2mV
3.Ripple and noise (p-p, 20MHz) (*8) mV 50 50 50 60 60 75 75 75 120 500
4.Ripple r.m.s. 5Hz~1MHz (*8) mV 6 6 6 7 7 10 12 8 20 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.01% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 20 20 20 20 20 20 25 50 100 100
Full load (*12) mS 30 30 60 60 60 60 60 120 220 200
10.Down-prog.response time:
No load (*12) mS 450 700 1000 1200 1500 1700 2600 2900 4600 4600
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12.Start up delay Sec Less than 6 Sec
13.Hold-up time mS 16ms typical, rated output power
CONSTANT CURRENT MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*6) --- 0.01% of rated output current. +2mA
2.Max. Load regulation (*9) --- 0.02% of rated output current. +5mA
3.Ripple r.m.s. @ rated voltage. B.W 5Hz~1MHz. (*13) mA ≤420 ≤160 ≤100 ≤60 ≤50 ≤30 ≤20 ≤10 ≤8 ≤5
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift ---
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*14) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*14) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout..
6.Output current monitor (*14) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5 of rated Iout.%.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
8. TRIGGER IN / TRIGGER OUT signals --- Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive
edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
2. Series operation --- Possible. Two identical units. Refer to instruction manual.
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 60 80 100 150 300 600
RS232/485, Optional IEEE (*18) Interfaces)
1.Vout programming accuracy (*15) --- 0.05% of rated output voltage
2.Iout programming accuracy (*14) --- 0.1% of actual output current+0.2% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*14) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.002% 0.002% 0.011% 0.007% 0.004% 0.002%
8.Iout readback resolution (of rated output current)) % 0.007% 0.002% 0.003% 0.003% 0.005% 0.006% 0.007% 0.010% 0.003% 0.004`%
18
™ 1kW/1.7kW SERIES SPECIFICATIONS
PROTECTIVE FUNCTIONS V 10 20 30 40 60 80 100 150 300 600
Output shut-down when power supply changes mode from CV or Power Limit to CC mode or from CC or Power Limit to CV mode.
1.Foldback protection --- User presetable. Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
2.Over-voltage protection (OVP) --- Output shut-down. Reset by AC input recycle in autostart mode, by OUTPUT button, by rear panel or by communication.
3.Over -voltage programming range V 0.5~12 1~24 2~36 2~44.1 5~66.15 5~88.2 5~110.25 5~165.37 5~330.75 5~661.5
4. Over-voltage programming accuracy --- +/-1% of rated output voltage
5.Output under voltage limit (UVL) --- Prevents from adjusting Vout below limit. Does not apply in analog programming. Preset by front panel or communication port.
6.Over temperature protection --- Shuts down the output. Auto recovery by autostart mode.
7. Output under voltage limit (UVL) --- Prevents adjustment of Vout below limit.
Prevents adjustment of Vout below limit. P.S output turns Off during under voltage condition. Reset by AC input recycle in autostart
8. Output under voltage protection (UVP) --- mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
FRONT PANEL
1.Control functions --- Multiple options with 2 Encoders
--- Vout/Iout/Power Limit manual adjust
--- OVP/UVL/UVP manual adjust
--- Protection Functions - OVP, UVL,UVP, Foldback, OCL, ENA, ILC
--- Communication Functions - Selection of LAN,IEEE,RS232,RS485,USB or Optional communication interface.
--- Output ON/OFF. Front Panel Lock.
--- Communication Functions - Selection of Baud Rate, Address, IP and communication language.
--- Analog Control Functions - Selection Voltage/resistive programming, 5V/10V, 5K/10K programming
--- Analog Monitor Functions - Selection of Voltage/Current Monitoring 5V/10V.
2.Display --- Vout: 4 digits, accuracy: 0.05% of rated output voltage +/-1 count.
--- Iout: 4 digits, accuracy: 0.2% of rated output current +/-1 count.
3.Front Panel Buttons Indications --- OUTPUT ON, ALARM, PREVIEW, FINE, COMMUNICATION, PROTECTION,CONFIGURATION, SYSTEM, SEQUENCER.
Voltage, Current, Power, CV, CC, CP, External Voltage, External Current, Address, LFP, Autostart, Safetstart, Foldback V/I, Remote
4. Front Panel Display Indications --- (communication), RS/USB/LAN/IEEE communication, Trigger, Load/Store Cell.
ENVIRONMENTAL CONDITIONS
1.Operating temperature --- 0~50°C, 100% load.
2.Storage temperature --- -30~85°C
3.Operating humidity % 20~90% RH (no condensation).
4.Storage humidity % 10~95% RH (no condensation).
5.Altitude --- Operating: 10000ft (3000m), output current derating 2%/100m or Ta derating 1°C/100m above 2000m. Non operating: 40000ft (12000m).
MECHANICAL
1.Cooling --- Forced air cooling by internal fans. Air flow direction: from Front panel to power supply rear
2.Weight kg Less than 5kg.
3.Dimensions (WxHxD) mm W: 423, H: 43.6, D: 441.5 (Without busbars and busbars cover),
W: 423, H: 43.6, D: 553.2 (Including busbars and busbars cover) (Refer to Outline drawing).
4.Vibration --- MIL-810G, method 514.6, Procedure I, test condition Annex C - 2.1.3.1
5.Shock --- Less than 20G, half sine, 11mSec. Unit is unpacked.
SAFETY/EMC
1.Applicable standards: Safety G1kW/G1.7kW --- UL61010-1, CSA22.2 No.61010-1, IEC61010-1, EN61010-1.
Vout≤50V Models: Output, J1, J2, J3, J4, J5, J6, J7, J8 (sense) & J9 (communication options) are Non Hazardous.
1.1. Interface classification G1kW/1.7kW --- 60≤Vout≤600V Models: Output & J8 (sense) are hazardous, J1, J2, J3, J4, J5, J6, J7 & J9 (communication options) are Non Hazardous.
Vout≤50V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Input - Ground: 2835VDC 1min.
60V≤Vout≤100V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 850VDC 1min.
1.2 Withstand voltage G1kW/1.7kW --- Output & J8 (sense) - Ground: 1500VDC 1min, Input - Ground: 2835VDC 1min.
100V<Vout≤600V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communication options): 4242VDC 1min.
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 1275VDC 1min.
Output & J8 (sense) - Ground: 2500VDC 1min.
Input - Ground: 2835VDC 1min.
1.3 Insulation resistance --- 100Mohm at 25ºC, 70%RH. Output to Ground 500VDC
2.Conducted emmision --- IEC/EN61204-3 Industrial environment, Annex H table H.1 , FCC Part 15-A, VCCI-A .
3.Radiated emission --- IEC/EN61204-3 Industrial environment, Annex H table H.3 and H4, FCC Part 15-A, VCCI-A
4. EMC compliance EMC (*4) --- According to IEC/EN61204-3 Industrial environment
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50°C
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 100-240Vac (50/60Hz).
*4: Signal and control ports interface cables length: Less than 3m, DC output power port cables length: Less than 30m.
*5: Not including EMI filter inrush current, less than 0.2mSec.
*6: 85~132Vac or 170~265Vac. Constant load.
*7: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
*8: For 10V~150V models: Measured with JEITA RC-9131C (1:1) probe. For 200~600V models: Measured with 100:1 probe.
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.
*10: The maximum voltage on the power supply terminals must not exceed the rated voltage.
*11: From 10% to 90% of Rated Output Voltage, with rated, resistive load.
*12: From 90% to 10% of Rated Output Voltage.
*13: For 10V model, the ripple is measured at 20~100% of rated output voltage and rated output current. For other models, the ripple is measured at 10~100% of rated output
voltage and rated output current. B.W 5Hz~1MHz.
*14: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
*15: Measured at the sensing point.
*16 Max. ambient temperature for using IEEE is 40°C.
*17: Ta=25°C, rated output power.
19
™ 2.7kW SERIES SPECIFICATIONS
OUTPUT RATING G 10-265 20-135 30-90 40-68 60-45 80-34 100-27 150-18 300-9 600-4.5
1.Rated output voltage(*1) V 10 20 30 40 60 80 100 150 300 600
2.Rated output current (*2) A 265 135 90 68 45 34 27 18 9 4.5
3.Rated output power W 2650 2700 2700 2720 2700 2720 2700 2700 2700 2700
INPUT CHARACTERISTICS V 10 20 30 40 60 80 100 150 300 600
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac)
3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac)
1.Input voltage/freq. 3 phase, 3 wire + Ground (*4) ---
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac)
1-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/208/230/240Vac)
3-Phase, 200V models: 10A @ 200Vac
2. Maximum Input current at 3-Phase, 400V models: --- 5.5A @ 380Vac
100% load 3-Phase, 480V models: 5.5A @ 380Vac
1-Phase, 200V models: 16.5A @ 200Vac
--- For 3-Phase: 0.94 @ 200/380Vac, rated output power.
3.Power Factor (Typ)
For 1-Phase: 0.99 @ 200Vac, rated output power.
4.Efficiency (Typ) (*5) (*22) % 88 89 89.5 90 90 90.5 90.5 90.5 90.5 90.5
5.Inrush current (*6) A Less than 50A
CONSTANT VOLTAGE MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*7) --- 0.01% of rated output voltage
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV
3.Ripple and noise (p-p, 20MHz) (*9) mV 75 75 75 75 80 80 100 120 200 480
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 8 10 10 12 15 15 15 20 60 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.05% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 30 30 30 30 50 50 50 50 50 100
Full load (*11) mS 50 50 80 80 80 100 100 100 100 200
10.Down-prog.response time:
No load (*12) mS 450 600 800 900 1100 1300 2100 2000 3200 3100
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12.Start up delay Sec Less than 6 Sec
CONSTANT CURRENT MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. @ rated voltage. 3-Phase (*14) mA ≤800 ≤450 ≤300 ≤150 ≤100 ≤70 ≤45 ≤30 ≤12 ≤5
4.Ripple r.m.s. @ rated voltage. 1-Phase (*14) mA ≤1200 ≤600 ≤300 ≤300 ≤200 ≤100 ≤60 ≤40 ≤12 ≤8
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift ---
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%.
6.Output current monitor (*15) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive
8. TRIGGER IN / TRIGGER OUT signals --- edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
2. Series operation --- Possible. Two identical units. Refer to instruction manual.
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 60 80 100 150 300 600
RS232/485, Optional IEEE(*19)(*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage
2.Iout programming accuracy (*15) --- 0.1% of actual output current+0.2% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*15) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.002% 0.002% 0.011% 0.007% 0.004% 0.002%
8.Iout readback resolution (of rated output current)) % 0.005% 0.008% 0.002% 0.002% 0.003% 0.004% 0.005% 0.007% 0.002% 0.003%
20
™ 3.4kW SERIES SPECIFICATIONS
OUTPUT RATING G 10-340 20-170 30-112 40-85 60-56 80-42 100-34 150-22.5 300-11.5 600-5.6
1.Rated output voltage(*1) V 10 20 30 40 60 80 100 150 300 600
2.Rated output current (*2) A 340 (*3) 170 112 85 56 42 34 22.5 11.5 5.6
3.Rated output power W 3400 3400 3360 3400 3360 3360 3400 3375 3450 3360
INPUT CHARACTERISTICS V 10 20 30 40 60 80 100 150 300 600
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac)
3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac)
1.Input voltage/freq. 3 phase, 3 wire + Ground (*4) ---
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac)
1-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/208/230/240Vac)
3-Phase, 200V models: 12.5A @ 200Vac
2. Maximum Input current at 3-Phase, 400V models: --- 6.5A @ 380Vac
100% load 3-Phase, 480V models: 6.5A @ 380Vac
1-Phase, 200V models: 21A @ 200Vac
--- For 3-Phase: 0.94 @ 200/380Vac, rated output power.
3.Power Factor (Typ)
For 1-Phase: 0.99 @ 200Vac, rated output power.
4.Efficiency (Typ) (*5) (*22) % 88 89 89.5 90 90 90.5 90.5 90.5 90.5 90.5
5.Inrush current (*6) A Less than 50A
CONSTANT VOLTAGE MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*7) --- 0.01% of rated output voltage
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV
3.Ripple and noise (p-p, 20MHz) (*9) mV 75 75 75 75 80 80 100 120 200 480
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 8 10 10 12 15 15 15 20 60 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.05% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 30 30 30 30 50 50 50 50 50 100
Full load (*11) mS 50 50 80 80 80 100 100 100 100 200
10.Down-prog.response time:
No load (*12) mS 450 600 800 900 1100 1300 2100 2000 3000 3100
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12.Start up delay Sec Less than 6 Sec
CONSTANT CURRENT MODE V 10 20 30 40 60 80 100 150 300 600
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. @ rated voltage. 3-Phase (*14) mA ≤800 ≤450 ≤300 ≤150 ≤100 ≤70 ≤45 ≤30 ≤12 ≤5
4.Ripple r.m.s. @ rated voltage. 1-Phase (*14) mA ≤1200 ≤600 ≤300 ≤300 ≤200 ≤100 ≤60 ≤40 ≤12 ≤8
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift ---
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%.
6.Output current monitor (*15) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive
8. TRIGGER IN / TRIGGER OUT signals --- edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
2. Series operation --- Possible. Two identical units. Refer to instruction manual.
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 60 80 100 150 300 600
RS232/485, Optional IEEE(*19)(*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage
2.Iout programming accuracy (*15) --- 0.1% of actual output current+0.2% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*15) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.002% 0.002% 0.011% 0.007% 0.004% 0.002%
8.Iout readback resolution (of rated output current)) % 0.004% 0.007% 0.010% 0.002% 0.003% 0.004% 0.004% 0.006% 0.010% 0.003%
21
™ 5kW SERIES SPECIFICATIONS
OUTPUT RATING G 10-500 20-250 30-170 40-125 50-100 60-85 80-65 100-50 150-34 200-25 300-17 400-13 500-10 600-8.5
1.Rated output voltage(*1) V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
2.Rated output current (*2) A 500 (*3) 250 170 125 100 85 65 50 34 25 17 13 10 8.5
3.Rated output power W 5000 5000 5100 5000 5000 5100 5200 5000 5100 5000 5100 5200 5000 5100
INPUT CHARACTERISTICS V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac)
1.Input voltage/freq. 3 phase, 3 wire + Ground (*4) --- 3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac)
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac)
3-Phase, 200V models: 17.5A @ 200Vac
2. Maximum Input current at 3-Phase, 400V models: --- 9.2A @ 380Vac
100% load
3-Phase, 480V models: 9.2A @ 380Vac
3.Power Factor (Typ) --- 0.94 @ 200/380Vac, rated output power.
4.Efficiency (Typ) (*5) (*22) % 89 (*21) 91 91 91 90 91 91 91 91 91 92 92 92 92
5.Inrush current (*6) A Less than 50A
CONSTANT VOLTAGE MODE V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
1.Max. Line regulation (*7) --- 0.01% of rated output voltage
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV
3.Ripple and noise (p-p, 20MHz) (*9) mV 75 75 75 75 75 75 80 90 120 200 200 400 450 480
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 8 10 12 12 12 12 15 15 20 45 60 80 80 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.05% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 30 30 30 30 50 50 50 50 50 50 50 100 100 100
Full load (*11) mS 50 50 80 80 80 80 100 100 100 100 100 150 200 200
10.Down-prog.response time:
No load (*12) mS 300 600 800 900 950 1000 1200 1900 2000 2500 3000 4000 4000 3000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12.Start up delay Sec Less than 5 Sec
CONSTANT CURRENT MODE V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. @ rated voltage. B.W 5Hz~1MHz (*14) mA ≤1200 ≤600 ≤300 ≤150 ≤130 ≤100 ≤70 ≤45 ≤45 ≤45 ≤15 ≤12 ≤10 ≤8
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift ---
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*15) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
8. TRIGGER IN / TRIGGER OUT signals --- Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V
positive edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to twelve (12) identical units in Master/Slave mode. Refer to instruction manual. For more power please consult with Factory.
2. Series operation --- Possible. Two identical units. Refer to instruction manual.
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
RS232/485, Optional IEEE(*19)(*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage
2.Iout programming accuracy (*15) --- 0.1% of actual output current+0.2% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*15) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.003% 0.002% 0.002% 0.011% 0.007% 0.005% 0.004% 0.003% 0.003% 0.002%
8.Iout readback resolution (of rated output current)) % 0.003% 0.005% 0.006% 0.009% 0.011% 0.002% 0.002% 0.003% 0.004% 0.004% 0.006% 0.008% 0.011% 0.002%
22
™ 2.7kW/3.4kW/5kW SERIES SPECIFICATIONS
PROTECTIVE FUNCTIONS V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
Output shut-down when power supply changes mode from CV or Power Limit to CC mode or from CC or Power Limit to CV mode.
1.Foldback protection --- User presetable. Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
2.Over-voltage protection (OVP) --- Output shut-down. Reset by AC input recycle in autostart mode, by OUTPUT button, by rear panel or by communication.
3.Over -voltage programming range V 0.5~12 1~24 2~36 2~44.1 5-55.125 5~66.15 5~88.2 5~110.25 5~165.37 5~220.5 5~330.75 5~441 5~551.25 5~661.5
4. Over-voltage programming accuracy --- +/-1% of rated output voltage
5.Output under voltage limit (UVL) --- Prevents from adjusting Vout below limit. Does not apply in analog programming. Preset by front panel or communication port.
6.Over temperature protection --- Shuts down the output. Auto recovery by autostart mode.
7. Output under voltage limit (UVL) --- Prevents adjustment of Vout below limit.
Prevents adjustment of Vout below limit. P.S output turns Off during under voltage condition. Reset by AC input recycle in autostart
8. Output under voltage protection (UVP) --- mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
FRONT PANEL
1.Control functions --- Multiple options with 2 Encoders
--- Vout/Iout/Power Limit manual adjust
--- OVP/UVL/UVP manual adjust
--- Protection Functions - OVP, UVL,UVP, Foldback, OCL, ENA, ILC
--- Communication Functions - Selection of LAN,IEEE,RS232,RS485,USB or Optional communication interface.
--- Output ON/OFF. Front Panel Lock.
--- Communication Functions - Selection of Baud Rate, Address, IP and communication language.
--- Analog Control Functions - Selection Voltage/resistive programming, 5V/10V, 5K/10K programming
--- Analog Monitor Functions - Selection of Voltage/Current Monitoring 5V/10V.
2.Display --- Vout: 4 digits, accuracy: 0.05% of rated output voltage +/-1 count.
--- Iout: 4 digits, accuracy: 0.2% of rated output current +/-1 count.
3.Front Panel Buttons Indications --- OUTPUT ON, ALARM, PREVIEW, FINE, COMMUNICATION, PROTECTION,CONFIGURATION, SYSTEM, SEQUENCER.
Voltage, Current, Power, CV, CC, CP, External Voltage, External Current, Address, LFP, Autostart, Safetstart, Foldback V/I, Remote
4. Front Panel Display Indications --- (communication), RS/USB/LAN/IEEE communication, Trigger, Load/Store Cell.
ENVIRONMENTAL CONDITIONS
1.Operating temperature --- 0~50°C, 100% load.
2.Storage temperature --- -30~85°C
3.Operating humidity % 20~90% RH (no condensation).
4.Storage humidity % 10~95% RH (no condensation).
5.Altitude (*17) --- Operating: 10000ft (3000m), output current derating 2%/100m or Ta derating 1°C/100m above 2000m. Non operating: 40000ft (12000m).
MECHANICAL
1.Cooling --- Forced air cooling by internal fans. Air flow direction: from Front panel to power supply rear
2.Weight kg 2.7kW/3.4kW - Less than 6.25kg. 5kW - Less than 7.5kg.
3.Dimensions (WxHxD) mm W: 423, H: 43.6, D: 441.5 (Without busbars and busbars cover),
W: 423, H: 43.6, D: 553.2 (Including busbars and busbars cover) (Refer to Outline drawing).
4.Vibration --- MIL-810G, method 514.6, Procedure I, test condition Annex C - 2.1.3.1
5.Shock --- Less than 20G, half sine, 11mSec. Unit is unpacked.
SAFETY/EMC
1.Applicable standards: Safety --- UL61010-1, CSA22.2 No.61010-1, IEC61010-1, EN61010-1.
Vout≤50V Models: Output, J1, J2, J3, J4, J5, J6, J7, J8 (sense) & J9 (communication options) are Non Hazardous.
1.1. Interface classification --- 60≤Vout≤600V Models: Output & J8 (sense) are hazardous, J1, J2, J3, J4, J5, J6, J7 & J9 (communication options) are Non Hazardous.
Vout≤50V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Input - Ground: 2835VDC 1min.
60V≤Vout≤100V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 850VDC 1min.
1.2 Withstand voltage --- Output & J8 (sense) - Ground: 1500VDC 1min, Input - Ground: 2835VDC 1min.
100V<Vout≤600V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communication options): 4242VDC 1min.
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 1275VDC 1min.
Output & J8 (sense) - Ground: 2500VDC 1min.
Input - Ground: 2835VDC 1min.
1.3 Insulation resistance --- 100Mohm at 25ºC, 70%RH. Output to Ground 500VDC
2.Conducted emmision --- IEC/EN61204-3 Industrial environment, Annex H table H.1 , FCC Part 15-A, VCCI-A.
3.Radiated emission --- IEC/EN61204-3 Industrial environment, Annex H table H.3 and H4, FCC Part 15-A, VCCI-A
4. EMC compliance EMC(*18) --- IEC/EN61204-3 Industrial environment
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50° C.
NOTES:
* 1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
* 2: Minimum current is guaranteed to maximum 0.2% of rated output current.
* 3: G5kW : Derate 5A/1°C above 40°C G3.4kW : Derate 5A/1°C above 40°C,
* 4: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 190-240Vac (50/60Hz) for 3-Phase
* 5: 3-Phase 200V models: At 200Vac input voltage, 3-Phase 400/480V: At 380Vac input voltage. With rated output power.
* 6: Not including EMI filter inrush current, less than 0.2mSec.
* 7: 3-Phase 200V models: 170~265Vac, 3-Phase 400V models: 342~460Vac, 3-Phase 480V models: 342~528Vac. Constant load.
* 8: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
* 9: For 10V~150V models: Measured with JEITA RC-9131C (1:1) probe. For 200~600V model: Measured with 100:1 probe.
* 10: The maximum voltage on the power supply terminals must not exceed the rated voltage.
* 11: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load.
* 12: From 90% to 10% of Rated Output Voltage.
* 13: For load voltage change, equal to the unit voltage rating, constant input voltage.
* 14: For 10V model, the ripple is measured at 20~100% of rated output voltage and rated output current. For other models, the ripple is measured at 10~100% of rated output
voltage and rated output current. B.W 5Hz~1MHz.
* 15: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
* 16: Measured at the sensing point.
* 17: For 10V model Ta derating 2°C/100m.
* 18 Signal and control ports interface cables length: Less than 3m, DC output power port cables length: Less than 30m.
* 19 Max. ambient temperature for using IEEE is 40°C.
* 20 For 10V model only: Max. output current for using IEEE is 400A up to 40°C and 450A up to 30°C.
* 21: For 10V model only: For 3-Phase 200V efficiency is 88.5%
* 22: Typ. at Ta=25°C, rated output power.
23
™ 5kW SERIES SPECIFICATIONS 1000-5 - 1500-3.4
OUTPUT RATING G 1000-5 1500-3.4
1.Rated output voltage(*1) V 1000 1500
2.Rated output current (*2) A 5 3.4
3.Rated output power W 5000 5000
INPUT CHARACTERISTICS V 1000 1500
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac)
1.Input voltage/freq. 3 phase, 3 wire + Ground (*4) ---
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac)
2. Maximum Input current at 3-Phase, 200V models: --- 17.5A @ 200Vac
100% load 3-Phase, 480V models: --- 9.2A @ 380Vac
3.Power Factor (Typ) --- 0.94 @ 200/380Vac, rated output power.
4.Efficiency (Typ) (*5) (*3) % 92 92
5.Inrush current (*6) A Less than 65A
CONSTANT VOLTAGE MODE V 1000 1500
1.Max. Line regulation (*7) --- 0.01% of rated output voltage
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV
3.Ripple and noise (p-p, 20MHz) (*9) mV 900 900
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 200 200
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.05% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 5 5
9.Up-prog. Response time (*11) mS 150 150
Full load (*11) mS 100 100
10.Down-prog.response time:
No load (*12) mS 3000 3000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. 2mS typical.
12.Start up delay Sec Less than 5 Sec
13. Hold up time mS 5mS typical. Rated output power.
CONSTANT CURRENT MODE V 1000 1500
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. @ rated voltage. B.W 5Hz~1MHz (*14) mA ≤7 ≤4
4.Temperature coefficient PPM/°C 70PPM/°C from rated output current, following 30 minutes warm-up.
5.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
6. Warm-up drift --- Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*15) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- Analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- "Enable/Disable PS output by electrical signal or dry contact. Output ON: 0~0.6V or short. Output OFF: 2~30V or open."
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
8. TRIGGER IN / TRIGGER OUT signals --- Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive
edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to four (4) identical units in Master/Slave mode. Refer to instruction manual. For more power please consult with Factory.
2. Series operation --- Not Possible
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 1000 1500
RS232/485, Optional IEEE(*19)(*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage
2.Iout programming accuracy (*15) --- 0.1% of actual output current+0.2% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.003% of rated output current
5.Vout readback accuracy --- 0.1% of rated output voltage
6.Iout readback accuracy (*15) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.007%
8.Iout readback resolution (of rated output current)) % 0.002% 0.003%
24
™ 5kW SERIES SPECIFICATIONS 1000-5 - 1500-3.4
PROTECTIVE FUNCTIONS V 1000 1500
Output shut-down when power supply changes mode from CV or Power Limit to CC mode or from CC or Power Limit to CV mode. User
1.Foldback protection --- presetable. Reset by AC input recycle in AutoStart mode, by Power switch, by OUTPUT button, by rear panel or by communication.
2.Over-voltage protection (OVP) --- Output shut-down. Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
3.Over -voltage programming range V 5~1212.75 5~1653.75
4. Over-voltage programming accuracy --- +/-1% of rated output voltage
5.Output under voltage limit (UVL) --- Prevents from adjusting Vout below limit. Does not apply in analog programming. Preset by front panel or communication port.
6.Over temperature protection --- Shuts down the output. Auto recovery by autostart mode.
Prevents adjustment of Vout below limit. P.S output turns Off during under voltage condition. Reset by AC input recycle in autostart
7. Output under voltage protection (UVP) --- mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
FRONT PANEL
1.Control functions --- Multiple options with 2 Encoders
--- Vout/Iout/Power Limit manual adjust
--- OVP/UVL/UVP manual adjust
--- Protection Functions - OVP, UVL,UVP, Foldback, OCL, ENA, ILC
--- Communication Functions - Selection of LAN,IEEE,RS232,RS485,USB or Optional communication interface.
--- Output ON/OFF. Front Panel Lock.
--- Communication Functions - Selection of Baud Rate, Address, IP and communication language.
--- Analog Control Functions - Selection Voltage/resistive programming, 5V/10V, 5K/10K programming
--- Analog Monitor Functions - Selection of Voltage/Current Monitoring 5V/10V.
2.Display --- Vout: 4 digits, accuracy: 0.05% of rated output voltage +/-1 count.
--- Iout: 4 digits, accuracy: 0.2% of rated output current +/-1 count.
3.Front Panel Buttons Indications --- OUTPUT ON, ALARM, PREVIEW, FINE, COMMUNICATION, PROTECTION,CONFIGURATION, SYSTEM, SEQUENCER.
Voltage, Current, Power, CV, CC, CP, External Voltage, External Current, Address, LFP, Autostart, Safetstart, Foldback V/I, Remote
4. Front Panel Display Indications --- (communication), RS/USB/LAN/IEEE communication, Trigger, Load/Store Cell.
ENVIRONMENTAL CONDITIONS
1.Operating temperature --- 0~50°C, 100% load.
2.Storage temperature --- -30~85°C
3.Operating humidity % 20~90% RH (no condensation).
4.Storage humidity % 10~95% RH (no condensation).
5.Altitude (*17) --- Operating: 10000ft (3000m), output current derating 2%/100m or Ta derating 1°C/100m above 1500m. Non operating: 40000ft (12000m).
MECHANICAL
1.Cooling --- Forced air cooling by internal fans. Air flow direction: From front panel to power supply rear
2.Weight kg Less than 8.5Kg.
3.Dimensions (WxHxD) mm W: 423, H: 43.6, D: 486.5 (Without busbars and busbars cover), W: 423, H: 43.6, D: 598.1 (Including busbars and busbars
cover) Refer to Outline drawing.
4.Vibration --- MIL-810G, method 514.6, Procedure I, test condition Annex C - 2.1.3.1
5.Shock --- Less than 20G, half sine, 11mSec. Unit is unpacked.
SAFETY/EMC
1. Safety standards: Safety --- UL61010-1, CSA22.2 No.61010-1, IEC61010-1, EN61010-1.
1.1. Interface classification --- Output & J8 (sense) are hazardous, J1, J2, J3, J4, J5, J6, J7 & J9 (communication options) are Non Hazardous.
Input - Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communicatoin options): 4000VDC 1min, Output & J8 (sense) - J1,
1.2 Withstand voltage --- J2, J3, J4, J5, J6, J7 and J9 (communicatoin options): 2000VDC 1min, Output & J8 (sense) - Ground: 3280VDC 1min. Input -
Ground: 2835VDC 1min.
1.3 Insulation resistance --- >100Mohm at 25°C, 70%RH, Output to Ground 500VDC.
2.EMC standards (*18) --- IEC/EN61204-3 Industrial environment.
2.1. Conducted emmision --- IEC/EN61204-3 Industrial environment, Annex H table H.1 , FCC Part 15-A, VCCI-A.
2.2. Radiated emission --- IEC/EN61204-3 Industrial environment, Annex H table H.3 and H4, FCC Part 15-A, VCCI-A
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50° C.
25
™ 7.5kW SERIES SPECIFICATIONS
OUTPUT RATING G 20-375 30-250 40-188 60-125 80-94 100-75 150-50 200-37.5 300-25 600-12.5 1000-7.5 1500-5
1.Rated output voltage(*1) V 20 30 40 60 80 100 150 200 300 600 1000 1500
2.Rated output current (*2) A 375 250 188 125 94 75 50 37.5 25 12.5 7.5 5
3.Rated output power W 7500 7500 7520 7500 7520 7500 7500 7500 7500 7500 7500 7500
INPUT CHARACTERISTICS V 20 30 40 60 80 100 150 200 300 600 1000 1500
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac).
1.Input voltage/freq. 3 phase, 3 wire+ground (*4) ---
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac).
2.Maximum Input current at 3-Phase, 200V models: 25.5A @ 200Vac.
---
100% load 3-Phase, 480V models: 13.5A @ 380Vac.
3.Power Factor (Typ.) --- 0.94 @ 200/380Vac, rated output power.
4.Efficiency (Typ.) (*5) (*3) % 91 91 91 91 91 91 91 91 91 92 92 92
5.Inrush current (*6) A Less than 65A.
CONSTANT VOLTAGE MODE V 20 30 40 60 80 100 150 200 300 600 1000 1500
1.Max. Line regulation (*7) --- 0.01% of rated output voltage.
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV.
3.Ripple and noise (p-p, 20MHz) (*9) mV 80 80 80 80 90 90 150 250 150 450 1100 1300
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 10 10 8 12 15 15 20 45 60 100 250 500
5.Temperature coefficient --- 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
7.Warm-up drift --- Less than 0.05% of rated output voltage +2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 5 5 5 5 5 5 5 5 5 5 5
9.Up-prog. response time (*11) mS 30 30 30 50 50 50 50 50 50 100 150 200
Full load (*11) mS 50 80 80 80 100 100 100 100 100 100 100 100
10.Down-prog. response time
No load (*12) 600 500 1000 1000 1000 1500 2500 2000 3000 3000 3000 3000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current.
11.Transient response time --- Output set point: 10~100%, Local sense.
Less than 1mS for models up to and including 100V. 2mS for models above 100V.
12.Start up delay --- Less than 5Sec.
13.Hold-up time --- 5mS Typical. Rated output power.
CONSTANT CURRENT MODE V 20 30 40 60 80 100 150 200 300 600 1000 1500
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. 5Hz~1MHz (*14) mA ≤900 ≤500 ≤300 ≤150 ≤100 ≤70 ≤45 ≤20 ≤15 ≤14 ≤10 ≤5
20V~100V models: 100PPM/OC from rated output current, following 30 minutes warm-up.
4.Temperature coefficient PPM/°C
150V~1500V models: 70PPM/OC from rated output current, following 30 minutes warm-up.
5.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
20V~100V models: Less than +/-0.25% of rated output current over 30 minutes following power on.
6.Warm-up drift ---
150V~1500V models: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10KΩ full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*15) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1.Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V. Maximum Sink Current: 10mA.
2.CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V. Maximum Sink Current: 10mA.
3.LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4.LOCAL/REMOTE Analog signal --- Analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V. Maximum Sink Current: 10mA.
5.ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6.INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Output ON: 0~0.6V or short. Output OFF: 2~30V or open.
7.Programmed signals --- Two open drain programmable signals. Maximum voltage 25V. Maximum sink current 100mA (shunted by 27V zener).
Maximum low level input voltage = 0.8V. Minimum high level input voltage = 2.5V.
8.TRIGGER IN / TRIGGER OUT signals --- Maximum high level input = 5V positive edge trigger: tw = 10us minimum. Tr,Tf = 1us maximum.
Min delay between 2 pulses 1ms.
9.DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10.DAISY_OUT/PS_OK #2 signal --- 4~5V = OK, 0V (500Ω impedance) = Fail.
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to 4 identical units in Master/Slave mode. Refer to instruction manual.
2. Series operation --- Possible. Two identical units. Refer to instruction manual.
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a programmed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via communication ports or front panel.
Programmable Output rise and Output fall slew rate.
6. Slew rate control --- Programming range: 0.0001~999.99 V/mS. or A/mS.
Programming via communication ports or front panel.
Profiles of up to 100 steps can be stored in 4 memory cells.
7. Arbitrary waveforms --- Activation by command via communication ports or front panel.
PROGRAMMING AND READBACK V 20 30 40 60 80 100 150 200 300 600 1000 1500
(USB, LAN, RS232/485, Optional (*17) (*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage.
2.Iout programming accuracy (*15) --- 0.1% of actual output current +0.2% of rated output current.
3.Vout programming resolution --- 0.002% of rated output voltage.
4.Iout programming resolution --- 0.002% of rated output current.
5.Vout readback accuracy --- 0.05% of rated output voltage.
6.Iout readback accuracy (*15) --- 0.2% of rated output current.
7.Vout readback resolution of rated output % 0.006% 0.004% 0.003% 0.002% 0.002% 0.011% 0.007% 0.005% 0.004% 0.002% 0.011% 0.007%
8.Iout readback resolution of rated output current % 0.003% 0.005% 0.006% 0.009% 0.002% 0.002% 0.003% 0.003% 0.005% 0.009% 0.002% 0.003%
26
™ 7.5kW SERIES SPECIFICATIONS
PROTECTIVE FUNCTIONS V 20 30 40 60 80 100 150 200 300 600 1000 1500
Output shut-down when power supply changes mode from CV or Power Limit to CC mode or from CC or Power Limit to CV mode. User presetable.
1.Foldback protection --- Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
2.Over-voltage protection (OVP) --- Output shut-down. Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
3.Over-voltage programming range V 1~24 2~36 2~44.1 5~66.15 5~88.2 5~110.25 5~165.37 5~220.5 5~330.75 5~661.5 5~1212.75 5~1653.75
4.Over-voltage programming accuracy --- +/-1% of rated output voltage.
5.Output under voltage limit (UVL) --- Prevents from adjusting Vout below limit. Does not apply in analog programming. Preset by front panel or communication port.
6.Over temperature protection --- Shuts down the output. Auto recovery by autostart mode.
Prevents adjustment of Vout below limit. P.S output turns Off during under voltage condition.
7.Output under voltage protection (UVP) ---
Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
FRONT PANEL
1.Control functions --- Multiple options with 2 Encoders
--- Vout/Iout/Power Limit manual adjust
--- OVP/UVL/UVP manual adjust
--- Protection Functions - OVP, UVL,UVP, Foldback, OCL, ENA, ILC
--- Communication Functions - Selection of LAN,IEEE,RS232,RS485,USB or Optional communication interface.
--- Output ON/OFF. Front Panel Lock.
--- Communication Functions - Selection of Baud Rate, Address, IP and communication language.
--- Analog Control Functions - Selection Voltage/resistive programming, 5V/10V, 5K/10K programming
--- Analog Monitor Functions - Selection of Voltage/Current Monitoring 5V/10V.
2.Display --- Vout: 4 digits, accuracy: 0.05% of rated output voltage +/-1 count.
--- Iout: 4 digits, accuracy: 0.2% of rated output current +/-1 count.
3.Front Panel Buttons Indications --- OUTPUT ON, ALARM, PREVIEW, FINE, COMMUNICATION, PROTECTION,CONFIGURATION, SYSTEM, SEQUENCER.
Voltage, Current, Power, CV, CC, CP, External Voltage, External Current, Address, LFP, Autostart, Safetstart, Foldback V/I, Remote (communication),
4. Front Panel Display Indications --- RS/USB/LAN/IEEE communication, Trigger, Load/Store Cell.
ENVIRONMENTAL CONDITIONS
1.Operating temperature --- 0~50°C, 100% load.
2.Storage temperature --- -30~85°C
3.Operating humidity % 20~90% RH (no condensation).
4.Storage humidity % 10~95% RH (no condensation).
5.Altitude (*17) --- Operating: 10000ft (3000m), output current derating 2%/100m or Ta derating 1°C/100m above 2000m. Non operating: 40000ft (12000m).
MECHANICAL
1.Cooling ---Forced air cooling by internal fans. Airflow direction: From front panel to power supply rear.
2.Weight kg Less than 8.5Kg.
3.Dimensions (WxHxD) mm W: 423, H: 43.6, D: 486.5 (Without busbars and busbars cover),
W: 423, H: 43.6, D: 598.1 (Including busbars and busbars cover). Refer to Outline drawing.
4.Vibration --- MIL-810G, method 514.6, Procedure I, test condition Annex C - 2.1.3.1
5.Shock --- Less than 20G, half sine, 11mS. Unit is unpacked.
SAFETY/EMC
1.Applicable standards: Safety --- UL61010-1, CSA22.2 No.61010-1, IEC61010-1, EN61010-1.
Vout≤50V Models: Output, J1, J2, J3, J4, J5, J6, J7, J8 (sense) & J9 (communication options) are Non Hazardous.
1.1. Interface classification ---
60≤Vout≤1500V Models: Output & J8 (sense) are hazardous, J1, J2, J3, J4, J5, J6, J7 & J9 (communication options) are Non Hazardous.
Vout≤50V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Input - Ground: 2835VDC 1min.
60V≤Vout≤100V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 850VDC 1min, Output & J8 (sense) - Ground: 1500VDC 1min,
Input - Ground: 2835VDC 1min.
1.2 Withstand voltage --- 100V<Vout≤600V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communication options): 4242VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 1275VDC 1min, Output & J8 (sense) - Ground: 2500VDC 1min.
Input - Ground: 2835VDC 1min.
1000V<Vout≤1500V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communication options): 4000VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 2000VDC 1min, Output & J8 (sense) - Ground: 3280VDC 1min.
Input - Ground: 2835VDC 1min.
1.3.Isolation resistance --- 100Mohm at 25ºC, 70%RH. Output to Ground 500VDC
2.EMC standards (*18) --- IEC/EN61204-3 Industrial environment, Annex H table H.1 , FCC Part 15-A, VCCI-A.
2.1.Conducted emission --- IEC/EN61204-3 Industrial environment, Annex H table H.3 and H4, FCC Part 15-A, VCCI-A
2.2.Radiated emission --- IEC/EN61204-3 Industrial environment
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50° C.
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.15% of rated output voltage for 20V and 30V / 0.1% of rated output voltage for 40V and 1500V
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3 Typ. at Ta=25°C, rated output power.
*4: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 190-240Vac (50/60Hz) for 3-Phase 200V models
and 380~480Vac (50/60Hz) for 3-Phase 480V models.
*5: 3-Phase 200V models: At 200Vac input voltage, 3-Phase 400/480V: At 380Vac input voltage. With rated output power.
*6: Not including EMI filter inrush current, less than 0.2mS.
*7: 3-Phase 200V models: 170~265Vac, 3-Phase 480V models: 342~528Vac. Constant load.
*8: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
*9: For 20V~150V models: Measured with JEITA RC-9131C (1:1) probe. For 200~1500V models: Measured with 100:1 probe.
*10: The maximum voltage on the power supply terminals must not exceed the rated voltage.
*11: From 10% to 90% of Rated Output Voltage at rated resistive load.
*12: From 90% to 10% of Rated Output Voltage.
*13: For load voltage change, equal to the unit voltage rating, constant input voltage.
*14: The ripple is measured at 10~100% of rated output voltage and rated output current. B.W 5Hz~1MHz.
*15: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
*16: Measured at the sensing point.
*17 Max. ambient temperature for IEEE is 40°C.
*18: Signal and control ports interface cables length: Less than 3m, DC output power port cables length: Less than 30m.
27
™ GSP10kW SERIES SPECIFICATIONS
OUTPUT RATING GSP 10-1000 20-500 30-340 40-250 50-200 60-170 80-130 100-100 150-68 200-50 300-34 400-26 500-20 600-17
1.Rated output voltage(*1) V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
2.Rated output current (*2) A 1000 (*3) 500 340 250 200 170 130 100 68 50 34 26 20 17
3.Rated output power kW 10 10 10.2 10 10 10.2 10.4 10 10.2 10 10.2 10.4 10 10.2
INPUT CHARACTERISTICS V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac)
1.Input voltage/freq. 3 phase, 3 wire + Ground (*4) --- 3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac)
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac)
3-Phase, 200V models: 35A @ 200Vac
2. Maximum Input current at 3-Phase, 400V models: --- 18.4A @ 380Vac
100% load
3-Phase, 480V models: 18.4A @ 380Vac
3.Power Factor (Typ) --- 0.94 @ 200/380Vac, rated output power.
4.Efficiency (Typ) (*5) (*22) % 89 (*21) 90 91 91 91 91 91 91 91 91 92 92 91 92
5.Inrush current (*6) A Less than 100A
6.AC line phase imbalance % < 5%
CONSTANT VOLTAGE MODE V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
1.Max. Line regulation (*7) --- 0.01% of rated output voltage
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV
3.Ripple and noise (p-p, 20MHz) (*9) mV 75 75 75 75 75 75 80 90 120 200 200 400 450 480
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 8 10 12 12 12 12 15 15 20 45 60 80 80 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.05% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 30 30 30 30 50 50 50 50 50 50 50 100 100 100
Full load (*11) mS 50 50 80 80 80 80 100 100 100 100 100 150 200 200
10.Down-prog.response time:
No load (*12) mS 300 600 800 900 950 1000 1200 1900 2000 2500 3000 4000 4000 3000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12.Start up delay Sec Less than 7 Sec
CONSTANT CURRENT MODE
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. @ 10% rated voltage. B.W 5Hz~1MHz. (*14) mA 1500 1200 600 300 200 150 100 70 45 45 15 15 12 10
4.Ripple r.m.s. @ 100% rated voltage. B.W 5Hz~1MHz. (TA25°C) mA 1200 700 300 150 100 75 50 35 23 23 7.5 7.5 8 6
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
--- 10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%. Of rated Vout.
6.Output current monitor (*15) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%. Of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive
8. TRIGGER IN / TRIGGER OUT signals --- edge trigger: tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to four (4) identical GSP units. For more power please consult with Factory.
2. Series operation --- Consult with Factory
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
RS232/485, Optional IEEE (*19)(*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage
2.Iout programming accuracy (*15) --- 0.3% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*15) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.003% 0.002% 0.002% 0.011% 0.007% 0.005% 0.004% 0.003% 0.003% 0.002%
8.Iout readback resolution (of rated output current)) % 0.012% 0.003% 0.004% 0.005% 0.006% 0.007% 0.009% 0.012% 0.002% 0.003% 0.003% 0.004% 0.006% 0.006%
28
™ GSP15kW SERIES SPECIFICATIONS
OUTPUT RATING GSP 10-1500 20-750 30-510 40-375 50-300 60-255 80-195 100-150 150-102 200-75 300-51 400-39 500-30 600-25.5
1.Rated output voltage(*1) V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
2.Rated output current (*2) A 1500 (*3) 750 510 375 300 255 195 150 102 75 51 39 30 25.5
3.Rated output power kW 15 15 15.3 15 15 15.3 15.6 15 15.3 15 15.3 15.6 15 15.3
INPUT CHARACTERISTICS V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
3-Phase, 200V models: 170~265Vac, 47~63Hz (Covers 200/230Vac)
1.Input voltage/freq. 3 phase, 3 wire + Ground (*4) --- 3-Phase, 400V models: 342~460Vac, 47~63Hz (Covers 380/400/415Vac)
3-Phase, 480V models: 342~528Vac, 47~63Hz (Covers 380/400/415/440/460/480Vac)
3-Phase, 200V models: 52.5A @ 200Vac
2. Maximum Input current at 3-Phase, 400V models: --- 27.6A @ 380Vac
100% load
3-Phase, 480V models: 27.6A @ 380Vac
3.Power Factor (Typ) --- 0.94 @ 200/380Vac, rated output power.
4.Efficiency (Typ) (*5) (*22) % 89 (*21) 90 91 91 91 91 91 91 91 91 92 92 91 92
5.Inrush current (*6) A Less than 150A
6.AC line phase imbalance % < 5%
CONSTANT VOLTAGE MODE V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
1.Max. Line regulation (*7) --- 0.01% of rated output voltage
2.Max. Load regulation (*8) --- 0.01% of rated output voltage +5mV
3.Ripple and noise (p-p, 20MHz) (*9) mV 75 75 75 75 75 75 80 90 120 200 200 400 450 480
4.Ripple r.m.s. 5Hz~1MHz (*9) mV 8 10 12 12 12 12 15 15 20 45 60 80 80 100
5.Temperature coefficient PPM/°C 50PPM/°C from rated output voltage, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
7. Warm-up drift --- Less than 0.05% of rated output voltage+2mV over 30 minutes following power on.
8.Remote sense compensation/wire (*10) V 2 2 5 5 5 5 5 5 5 5 5 5 5 5
9.Up-prog. Response time (*11) mS 30 30 30 30 50 50 50 50 50 50 50 100 100 100
Full load (*11) mS 50 50 80 80 80 80 100 100 100 100 100 150 200 200
10.Down-prog.response time:
No load (*12) mS 300 600 800 900 950 1000 1200 1900 2000 2500 3000 4000 4000 3000
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. Output set-point:
11.Transient response time mS 10~100%, Local sense. Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
12..Start up delay Sec Less than 7 Sec
CONSTANT CURRENT MODE V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
1.Max. Line regulation (*7) --- 0.05% of rated output current.
2.Max. Load regulation (*13) --- 0.08% of rated output current.
3.Ripple r.m.s. @ 10% rated voltage B.W 5Hz~1MHz. (*14) mA 2000 1200 600 300 250 180 100 70 45 45 15 15 12 10
4.Ripple r.m.s. @ 100% rated voltage. B.W 5Hz~1MHz. (TA 25°C) mA 1200 700 300 150 130 90 60 35 23 23 7.5 7.5 8 6
10V~100V 100PPM/oC from rated output current, following 30 minutes warm-up.
5.Temperature coefficient PPM/°C
150V~600V 70PPM/oC from rated output current, following 30 minutes warm-up.
6.Temperature stability --- 0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
10V~100V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
7. Warm-up drift ---
150V~600V: Less than +/-0.15% of rated output current over 30 minutes following power on.
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
1.Vout voltage programming --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.15% of rated Vout.
2.Iout voltage programming (*15) --- 0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.4% of rated Iout.
3.Vout resistor programming --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
4.Iout resistor programming (*15) --- 0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-0.5% of rated Iout.
5.Output voltage monitor (*23) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5% of rated Vout.
6.Output current monitor (*15) (*23) --- 0~5V or 0~10V, user selectable. Accuracy: +/-0.5%. of rated Iout.
SIGNALS AND CONTROLS (ISOLATED FROM THE OUTPUT)
1. Power supply OK #1 signal --- Power supply output monitor. Open collector. Output On: On. Output Off: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
2. CV/CC signal --- CV/CC Monitor. Open collector. CC mode: On. CV mode: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
3. LOCAL/REMOTE Analog control --- Enable/Disable analog programming control by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
4. LOCAL/REMOTE Analog signal --- analog programming control monitor signal. Open collector. Remote: On. Local: Off. Maximum Voltage: 30V, Maximum Sink Current: 10mA.
5. ENABLE/DISABLE Signal --- Enable/Disable PS output by electrical signal or dry contact. 0~0.6V or short, 2~30V or open. User selectable logic.
6. INTERLOCK (ILC) control --- Enable/Disable PS output by electrical signal or dry contact. Remote: 0~0.6V or short. Local: 2~30V or open.
7. Programmed signals --- Two open drain programmable signals. Maximum voltage 25V, Maximum sink current 100mA (Shunted by 27V zener)
Maximum low level input voltage = 0.8V,Minimum high level input voltage = 2.5V, Maximum high level input = 5V positive edge trigger:
8. TRIGGER IN / TRIGGER OUT signals --- tw=10us minimum. Tr,Tf=1us Maximum, Min delay between 2 pulses 1ms.
9. DAISY_IN/SO control signal --- By electrical Voltage: 0~0.6V/2~30V or dry contact.
10. DAISY_OUT/PS_OK #2 signal --- 4~5V=OK, 0V (500ohm impedance)=Fail
FUNCTIONS AND FEATURES
1. Parallel operation --- Possible. Up to four (4) identical GSP units. For more power please consult with Factory.
2. Series operation --- Consult with Factory
3. Daisy chain --- Power supplies can be connected in Daisy chain to synchronize their turn-on and turn-off.
4. Constant power control --- Limits the output power to a proggrammed value. Programming via the communication ports or the front panel.
5. Output resistance control --- Emulates series resistance. Resistance range: 1~1000mΩ. Programming via the communication ports or the front panel.
Programmable Output rise and Output fall slew rate. Programming range: 0.0001~999.99 V/mSec. or A/mSec. Programming via the
6. Slew rate control --- communication ports or the front panel.
7. Arbitrary waveforms --- Profiles of up to 100 steps can be stored in 4 memory cells. Activation by command via the communication ports or by the front panel.
PROGRAMMING AND READBACK (USB, LAN, V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
RS232/485, Optional IEEE (*19)(*20) Interfaces)
1.Vout programming accuracy (*16) --- 0.05% of rated output voltage
2.Iout programming accuracy (*15) --- 0.3% of rated output current
3.Vout programming resolution --- 0.002% of rated output voltage
4.Iout programming resolution --- 0.002% of rated output current
5.Vout readback accuracy --- 0.05% of rated output voltage
6.Iout readback accuracy (*15) --- 0.2% of rated output current
7.Vout readback resolution (of rated output voltage) % 0.011% 0.006% 0.004% 0.003% 0.003% 0.002% 0.002% 0.011% 0.007% 0.005% 0.004% 0.003% 0.003% 0.002%
8.Iout readback resolution (of rated output current)) % 0.012% 0.003% 0.003% 0.004% 0.004% 0.005% 0.006% 0.008% 0.012% 0.002% 0.003% 0.003% 0.003% 0.005%
29
™ GSP10kW/15kW SERIES SPECIFICATIONS
PROTECTIVE FUNCTIONS V 10 20 30 40 50 60 80 100 150 200 300 400 500 600
Output shut-down when power supply changes mode from CV or Power Limit to CC mode or from CC or Power Limit to CV mode.
1.Foldback protection --- User presetable. Reset by AC input recycle in autostart mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
2.Over-voltage protection (OVP) --- Output shut-down. Reset by AC input recycle in autostart mode, by OUTPUT button, by rear panel or by communication.
3.Over -voltage programming range V 0.5~12 1~24 2~36 2~44.1 5~55.125 5~66.15 5~88.2 5~110.25 5~165.37 5~220.5 5~330.75 5~441 5~551.25 5~661.5
4. Over-voltage programming accuracy --- +/-1% of rated output voltage
5.Output under voltage limit (UVL) --- Prevents from adjusting Vout below limit. Does not apply in analog programming. Preset by front panel or communication port.
6.Over temperature protection --- Shuts down the output. Auto recovery by autostart mode.
7. Output under voltage limit (UVL) --- Prevents adjustment of Vout below limit.
Prevents adjustment of Vout below limit. P.S output turns Off during under voltage condition. Reset by AC input recycle in autostart
8. Output under voltage protection (UVP) --- mode, by Power Switch, by OUTPUT button, by rear panel or by communication.
FRONT PANEL
1.Control functions --- Multiple options with 2 Encoders
--- Vout/Iout/Power Limit manual adjust
--- OVP/UVL/UVP manual adjust
--- Protection Functions - OVP, UVL,UVP, Foldback, OCL, ENA, ILC
--- Communication Functions - Selection of LAN,IEEE,RS232,RS485,USB or Optional communication interface.
--- Output ON/OFF. Front Panel Lock.
--- Communication Functions - Selection of Baud Rate, Address, IP and communication language.
--- Analog Control Functions - Selection Voltage/resistive programming, 5V/10V, 5K/10K programming
--- Analog Monitor Functions - Selection of Voltage/Current Monitoring 5V/10V.
2.Display --- Vout: 4 digits, accuracy: 0.05% of rated output voltage +/-1 count.
--- Iout: 4 digits, accuracy: 0.2% of rated output current +/-1 count.
3.Front Panel Buttons Indications --- OUTPUT ON, ALARM, PREVIEW, FINE, COMMUNICATION, PROTECTION,CONFIGURATION, SYSTEM, SEQUENCER.
Voltage, Current, Power, CV, CC, CP, External Voltage, External Current, Address, LFP, Autostart, Safetstart, Foldback V/I, Remote
4. Front Panel Display Indications --- (communication), RS/USB/LAN/IEEE communication, Trigger, Load/Store Cell.
ENVIRONMENTAL CONDITIONS
1.Operating temperature --- 0~50°C, 100% load.
2.Storage temperature --- -30~85°C
3.Operating humidity % 20~90% RH (no condensation).
4.Storage humidity % 10~95% RH (no condensation).
5.Altitude (*17) --- Operating: 10000ft (3000m), output current derating 2%/100m or Ta derating 1°C/100m above 2000m. Non operating: 40000ft (12000m).
MECHANICAL
1.Cooling --- Forced air cooling by internal fans. Air flow direction: from Front panel to power supply rear
2.Weight GSP 10kW kg Less than 15.5kg.
3.Dimensions (WxHxD) GSP 10kW mm W: 423, H: 88, D: 441.5 (Without busbars and busbars cover),
W: 423, H: 88, D: 640 (Including busbars and busbars cover, and strain relief) (Refer to Outline drawing).
2.Weight GSP 15kW kg Less than 23.5kg.
W: 423, H: 132.5, D: 441.5 (Without busbars and busbars cover),
3.Dimensions (WxHxD) GSP 15kW mm W: 423, H: 132.5, D: 640 (Including busbars and busbars cover, and strain relief) (Refer to Outline drawing).
4.Vibration --- MIL-810G, method 514.6, Procedure I, test condition Annex C - 2.1.3.1
5.Shock --- Less than 20G, half sine, 11mSec. Unit is unpacked.
SAFETY/EMC
1.Applicable standards: Safety --- UL61010-1, CSA22.2 No.L61010-1, IECL61010-1, ENL61010-1.
Vout≤50V Models: Output, J1, J2, J3, J4, J5, J6, J7, J8 (sense) & J9 (communication options) are Non Hazardous.
1.1. Interface classification --- 60≤Vout≤600V Models: Output & J8 (sense) are hazardous, J1, J2, J3, J4, J5, J6, J7 & J9 (communication options) are Non Hazardous.
Vout≤50V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Input - Ground: 2835VDC 1min.
60V≤Vout≤100V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 4242VDC 1min,
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 850VDC 1min.
1.2 Withstand voltage --- Output & J8 (sense) - Ground: 1500VDC 1min, Input - Ground: 2835VDC 1min.
100V<Vout≤600V Models: Input – Output & J8 (sense), J1, J2, J3, J4, J5, J6, J7 and J9 (communication options): 4242VDC 1min.
Output & J8 (sense) - J1, J2, J3, J4, J5, J6, J7 & J9 (communication options): 1275VDC 1min.
Output & J8 (sense) - Ground: 2500VDC 1min.
Input - Ground: 2835VDC 1min.
1.3 Insulation resistance --- GSP10kW/15kW: 60 Mohm at 25ºC, 70%RH. Output to Ground 500VDC
2.Conducted emmision --- IEC/EN61204-3 Industrial environment, Annex H table H.1 , FCC Part 15-A, VCCI-A.
3.Radiated emission --- IEC/EN61204-3 Industrial environment, Annex H table H.3 and H4, FCC Part 15-A, VCCI-A.
4. EMC compliance EMC(*18) --- IEC/EN61204-3 Industrial environment
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0° to 50° C.
"NOTES:
*1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3: GSP 10kW: Derate 10A/1°C above 40°C. GSP 15kW: Derate 15A/1°C above 40°C.
*4: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 190-240Vac (50/60Hz) for 3-Phase
*5: 3-Phase 200V models: At 200Vac input voltage, 3-Phase 400/480V: At 380Vac input voltage. With rated output power.
*6: Not including EMI filter inrush current, less than 0.2mSec.
*7: 3-Phase 200V models: 170~265Vac, 3-Phase 400V models: 342~460Vac, 3-Phase 480V models: 342~528Vac. Constant load.
*8: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
*9: For 10V~150V models: Measured with JEITA RC-9131C (1:1) probe. For 200~600V models: Measured with 100:1 probe.
*10: The maximum voltage on the power supply terminals must not exceed the rated voltage.
*11: From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load.
*12: From 90% to 10% of Rated Output Voltage.
*13: For load voltage change, equal to the unit voltage rating, constant input voltage.
*14: For 10V model the ripple is measured at 2V and rated output current. For other models, the ripple is measured at 10% of rated output voltage. B.W 5Hz~1MHz.
*15: The Constant Current programming, readback and monitoring accuracy do not include the warm-up and Load regulation thermal drift.
*16: Measured at the sensing point.
*17: For 10V model Ta derating 2°C/100m."
*18:"Signal and control ports interface cables length: Less than 3m, DC output power port cables length: Less than 30m.
*19:Max. ambient temperature for using IEEE is 40°C.
*20:GSP10kW For 10V model only: Max. output current for using IEEE is 800A up to 40°C and 900A up to 30°C.
*20:GSP15kW For 10V model only: Max. output current for using IEEE is 1200A up to 40°C and 1350A up to 30°C.
*21: For 10V model only: For 3-Phase 200V efficiency is 88.5%
*22: Typ. at Ta=25°C, rated output power.
*23: For steady state only.
30
G1kW AC INPUT
Outline Drawing
KW
1/1.7 2.7 3.4
V
10 L1 L1 L1
20~40 L2 L1 L1
60~100 L2 L2 L2
™ G1kW/1.7kW/2.7kW/3.4kW - 1-Phase
31
Outline Drawing ™ G2.7kW/G3.4kW/G5kW - 3-Phase
(Not includes G+5kW models: 1000V & 1500V).
32
Outline Drawing ™ GB1kW/1.7kW/GB2.7kW/GB3.4kW/GB5kW - ATE Version
(Not includes G+5kW models: 1000V & 1500V).
G1kW AC INPUT
33
34
423 ±1
VIEW B
375.2 ±1 SCALE 1 : 4
IEEE OR ANYBUS
118.5 ±1 157.7 ±1 OPTIONS J9 OUTPUT BUS BAR (+) OUTPUT BUS BAR (-)
AC INPUT
57 ±1 42.5 ±0.5 INPUT CONNECTOR
PHOENIX CONTACT, SEE TABLE
DB26
PARALLEL REMOTE SENSE
CONNECTOR J1
CONNECTORS CONNECTOR
USB J7 (M) J6 (S) J8
LAN INPUT CONNECTOR
CONNECTOR J2
CONNECTOR J5 3PH 200VAC PC 6-16/ 4-GF-10.16
111.7 ±1
RS485 RS232 3PH 480VAC PC 5/ 4-G-7.62
CONNECTOR J3 CONNECTOR J4
Outline Drawing
598.2 ±1.5
ASSEMBLY IA922-51-11_
486.5 ±1.5
(SHIPPED IN PACKAGE)
SEE NOTE 2
21.5 ±1
27.2 ±1 25 ±0.5
64.7 ±1
SEE NOTE 3
31.8 ±0.5
AIR FLOW
134.8 63.6 DIRECTION
+0.7
466 ±1
5.9 ±0.5
24.5 ±0.5
482 ±1 43.6 - 0.3
™ G7.5kW - LV (20V-100V) 3-Phase
NOTE
1. MOUNTING HOLES FOR SLIDES P/N:CC3001-00-S160,GENERAL DEVICES OR EQUIVALENT.
USE #10-32x0.375 INCH x 3 SCREWS FOR EACH SLIDE.
ENSURE THAT THE SCREWS DO NOT PENETRATE MORE THAN 6.0mm INTO THE UNIT.
2. AC INPUT RATING , SAFETY APPROVAL SYMBOLS AND EU REPRESENTATIVE LABEL
ARE SHOWN HERE ACCORDING TO THE SPECIFICATIONS.
3. MODEL NAME , OUTPUT RATING AND COMPANY LOGO ARE SHOWN HERE ACCORDING TO THE SPECIFICATIONS.
4. MOUNTING HOLES FOR 19'' RACK, USE M6x16 SCREWS TO FIX THE UNIT TO THE RACK.
G+7.5KW 20V~100V
423 ±1
VIEW B
375.2 ±1 SCALE 1 : 4
IEEE OR ANYBUS
118.5 ±1 157.7 ±1 OPTIONS J9 OUTPUT BUS BAR (+) OUTPUT BUS BAR (-)
AC INPUT
57 ±1 42.5 ±0.5 INPUT CONNECTOR
PHOENIX CONTACT, SEE TABLE
DB26
PARALLEL REMOTE SENSE
CONNECTOR J1
CONNECTORS CONNECTOR
USB J7 (M) J6 (S) J8
LAN INPUT CONNECTOR
CONNECTOR J2
CONNECTOR J5 3PH 200VAC PC 6-16/ 4-GF-10.16
111.7 ±1
RS485 RS232 3PH 480VAC PC 5/ 4-G-7.62
CONNECTOR J3 CONNECTOR J4
598.2 ±1.5
Outline Drawing
ASSEMBLY IA922-51-11_
486.5 ±1.5
(SHIPPED IN PACKAGE)
SEE NOTE 2
21.5 ±1
34.2 ±1
45.2 ±1
SEE NOTE 3
31.8 ±0.5
AIR FLOW
134.8 63.6 DIRECTION
+0.7
466 ±1
5.9 ±0.5
24.5 ±0.5
43.6 - 0.3
482 ±1
NOTE
1. MOUNTING HOLES FOR SLIDES P/N:CC3001-00-S160,GENERAL DEVICES OR EQUIVALENT.
USE #10-32x0.375 INCH x 3 SCREWS FOR EACH SLIDE.
ENSURE THAT THE SCREWS DO NOT PENETRATE MORE THAN 6.0mm INTO THE UNIT.
2. AC INPUT RATING , SAFETY APPROVAL SYMBOLS AND EU REPRESENTATIVE LABEL
ARE SHOWN HERE ACCORDING TO THE SPECIFICATIONS.
™ G7.5kW - HV (150V-1500V) 3-Phase
3. MODEL NAME , OUTPUT RATING AND COMPANY LOGO ARE SHOWN HERE ACCORDING TO THE SPECIFICATIONS.
4. MOUNTING HOLES FOR 19'' RACK, USE M6x16 SCREWS TO FIX THE UNIT TO THE RACK.
G+7.5KW 150V~1500V
35
36
423 ±1
VIEW B
375.2 ±1 SCALE 1 : 4
IEEE OR ANYBUS
118.5 ±1 157.7 ±1 OPTIONS J9 OUTPUT BUS BAR (+) OUTPUT BUS BAR (-)
AC INPUT
57 ±1 42.5 ±0.5 INPUT CONNECTOR
PHOENIX CONTACT, SEE TABLE
DB26
PARALLEL REMOTE SENSE
CONNECTOR J1
CONNECTORS CONNECTOR
USB J7 (M) J6 (S) J8
LAN INPUT CONNECTOR
CONNECTOR J2
CONNECTOR J5 3PH 200VAC PC 6-16/ 4-GF-10.16
111.7 ±1
RS485 RS232 3PH 480VAC PC 5/ 4-G-7.62
CONNECTOR J3 CONNECTOR J4
Outline Drawing
598.2 ±1.5
DETAIL A
SCALE 1 : 1.5 AC CABLE STRAIN RELIEF
X2 SEE SAFETY MANUAL
8.5
(SHIPPED IN PACKAGE)
ASSEMBLY IA922-51-11_
486.5 ±1.5
(SHIPPED IN PACKAGE)
SEE NOTE 2
21.5 ±1
34.2 ±1
45.2 ±1
SEE NOTE 3
31.8 ±0.5
AIR FLOW
134.8 63.6 DIRECTION
+0.7
466 ±1
5.9 ±0.5
24.5 ±0.5
43.6 - 0.3
482 ±1
NOTE
1. MOUNTING HOLES FOR SLIDES P/N:CC3001-00-S160,GENERAL DEVICES OR EQUIVALENT.
USE #10-32x0.375 INCH x 3 SCREWS FOR EACH SLIDE.
ENSURE THAT THE SCREWS DO NOT PENETRATE MORE THAN 6.0mm INTO THE UNIT.
2. AC INPUT RATING , SAFETY APPROVAL SYMBOLS AND EU REPRESENTATIVE LABEL
ARE SHOWN HERE ACCORDING TO THE SPECIFICATIONS.
3. MODEL NAME , OUTPUT RATING AND COMPANY LOGO ARE SHOWN HERE ACCORDING TO THE SPECIFICATIONS.
4. MOUNTING HOLES FOR 19'' RACK, USE M6x16 SCREWS TO FIX THE UNIT TO THE RACK.
DIMENSION
L1
L2
60-100(V)
10-40(V)
MODEL
37
38
MODEL DIMENSION
10-40(V) L1
60-100(V) L2
Outline Drawing
™ GSP15kW
39
™ Air Filter Kit Outline Drawing
Front Panel Air Filter Assembly
Front panel dust cover is available for dusty air environment applications
Dust cover is removable snap-in filter (for easy maintenance)
Accessories
1. Front Panel dust filter / Field installation kit:
Technical Specifications: Unit with Air Filter Assembly Installed
• Derating (enviromental):
• Operating Temperature
• For all models (except 10V): 0 ̊C to +40 ̊C full load; For 10V model: 0 ̊C to +30 ̊C, derate 5A/ ̊C for 30 ̊C < Ta < +40 ̊C
• Altitude
• For all models (except 10V): derate 2 ̊C/100m or 2% of load/100m (above 2000m)
• For 10V model: derate 1 ̊C/100m or 2% of load/100m (above 2000m)
Filter Foam Technical Specifications
• Material: reticulated polyurethane foam
• Thickness:3.8 mm
• Porosity: 45ppi
• Operating Temperature Range: 0 ̊C to +60 ̊C
• Storage Temperature Range: -40 ̊C to +85 ̊C
• Humidity: 95% RH
Air Filter Assembly Components
Standard Unit (P/N: G-AFK)
• Air Filter Cover (two pieces)
• Slide Button #1 (two locations: near AC ON/OFF switch and near left-hand side of front panel display)
• Slide Button #2 (one location: right-hand side of front panel display)
• Filter foam (two pieces)
Blank Front Panel Unit (P/N: GB-AFK)
• Air Filter Cover (one piece)
• Slide Button #1 (two locations) • Filter foam (one piece)
40
41
™IA761-04-06 Rev. M
https://product.tdk.com/en/power