Programming Terminal PT 100 N Operating Manual
Programming Terminal PT 100 N Operating Manual
Operating instructions
PT100N - CE Parallel
CE Synchronous-serial
CE Incremental-serial
CE MLD - cam switch 8 / 18 cams
LA Parallel
LA Synchronous-serial
LA Incremental-serial
LA Cam switch 8 cams
Date: 03.09.2002
Document No.: TR - E - BA - GB - 0012 - 03
Soft edition: PT100N V21
File name: TR-E-BA-GB-0012.DOC
Author: MAS
TR Electronic GmbH
Eglishalde 6
D-78647 Trossingen
Imprint
TR-Electronic GmbH
D-78647 Trossingen
Eglishalde 6
Tel.: (0049) 07425/228-0
Fax: (0049) 07425/228-33
Guarantee
In our ongoing efforts to improve our products, TR-Electronic reserve the right to alter the
information contained in this document without prior notice.
Printing
This manual was produced on a personal computer using MS-Word for Windows. The text
was printed in Arial type.
Fonts
Italics and bold type are used for the title of a document or to emphasize text passages.
Passages written in Courier show text which is visible on the display as well as software
menu selections.
Note
Text following the "NOTE" symbol describes important features of the respective product.
Copyright Information ©
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 2 of 68
Operating instructions PT100N ELECTRONIC GmbH
Revision History
i Note:
The cover of this document shows the current revision status and the corresponding date.
Since each individual page has its own revision status and date in the footer, there may be
different revision statuses within the document.
Revision Date
New soft version PT 100N V2.1a 02.12.1996
Supplementation: menu chart
New: chapter "EPROG DIALOG (Version 2.1a and above)"
Correction:
Page 37, chap. 3.3.1.17 Preset position:
19.11.1999
"The CE-MLD (without version V001) cam switch with 18
cams does not support the preset function" was deleted, since
the encoder supports the preset function.
Additional notes for the LA-Camshaft-Gear (LA-NSW)
Chapter "Steps / length", page 35 03.09.2002
Chapter "Correction value", page 44
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 3 of 68
Operating instructions PT100N ELECTRONIC GmbH
Contents
4 Appendix ........................................................................................................................................57
4.1 Programming examples...................................................................................................57
4.2 Synchronous serial interface SSI ....................................................................................60
4.3 SSI output treeformat ......................................................................................................61
4.4 SSI transmit format left binding .......................................................................................62
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 5 of 68
Operating instructions PT100N ELECTRONIC GmbH
E ncoder 1 Encoder 2
PE
S h ie ld S h i e ld
S w itc h c a b in e t m o d u le 1 S w it c h c a b in e t m o d u le 2
1 5 - p o le S U B - D
E n c o d e r d a ta to E n c o d e r d a ta to
F la t r ib b o n c a b le
c u m s to m e r c u s to m e r
e le c tr o n ic s e le c tr o n ic s
S w itc h c a b in e t
1 6 - p o le s o c k e t
TR E le c tr o n ic
* PT100N V20 *
PT 100N
F1 F2 F3 F4 exchange
! 7 8 9
" 4 5 6
± 1 2 3
CE . 0 ENTER
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 6 of 68
Operating instructions PT100N ELECTRONIC GmbH
15-pole SUB-D
connector
TR Electronic
* PT100N V20 *
PT 100N
F1 F2 F3 F4
! 7 8 9 PT100N
" 4 5 6
± 1 2 3
CE . 0 ENTER
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 7 of 68
Operating instructions PT100N ELECTRONIC GmbH
3 Menu chart
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 8 of 68
Operating instructions PT100N ELECTRONIC GmbH
3.1 Operation
Connector plug
Display
2 X 16 digits
Back to main
menu Back
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 9 of 68
Operating instructions PT100N ELECTRONIC GmbH
Operation:
After switch-on the main menu appears when pressing any key.
The actual menu quits automatically with the last confirmation. The next menu item is indicated
automatically after correct operation. If a modification routine is interrupted the next menu will not be
indicated.
Each function can be canceled with F2. Data which have been modified and confirmed with the
ENTER key will be kept.
Go back by pressing key F2 several times.
A direct selection of the language is possible with the keys F1, F2 or F3. The respective key must be
pressed when switching on the power supply.
Notice:
With EPROG encoders the data verification may lead to an error message because of different
internal checks. Please read data again and check in „EDIT“ menu.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 10 of 68
Operating instructions PT100N ELECTRONIC GmbH
The encoder data are normally saved in the encoder itself. In order to change them they have to be
transmitted to the PT100N. This procedure is done in the Read menu.
If no valid data are loaded, some of the following menu items cannot be activated.
Data which have been loaded are available until the power supply is switched off. It is possible to copy
data from one encoder to another encoder of the same design.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 11 of 68
Operating instructions PT100N ELECTRONIC GmbH
This central menu item has three further sub-menu items. Set the new encoder data here. Dependent
on the encoder connected, the following sub-menu items are available:
- EDIT ENCODER
Modification of all encoder-specific parameters
- EDIT CAMS
Modification of the cam parameters for cam switches
- EDIT TA-MINI
Modification of all TA-Mini-specific parameters
Use the cursor keys to select the corresponding sub-menu. The menu selected is indicated when
pressing the Enter key.
Within these menus the Enter key must be used to change to the next function. Go back to the
previous function with F3.
Selection is done with the cursor keys and confirmed with the Enter key.
Edit functions can be confirmed direct or, after a modification, must be completed with the Enter key.
An invalid value is corrected automatically by the PT100N. Confirm the valid value then with the Enter
key.
If an entry is canceled with F3, the previous function is indicated . Modified values of the canceled
function are not accepted.
When the Edit menus are canceled with F2 the complete editing becomes invalid, the data confirmed
so far, however, will be kept. To save the data after cancellation is not possible.
When the editing is proceeded continuously the next menu appears automatically after all data of the
current menu have been edited. The „SAVE“ menu on a higher level appears after the last submenu
has been edited.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 12 of 68
Operating instructions PT100N ELECTRONIC GmbH
The functions which can be selected here are independent from the encoder connected and the
parameters set. Functions which are not supported by the encoder will not be indicated.
Functions that are excluded by previous parameters will not be indicated as well.
E.g. preset values, if the preset inputs are locked, that means if „LOCKED“ has been selected in the
function „PRESET REACTION“, the function „PRESET POSITION“ which normally follows, will not be
indicated.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 13 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder CE with parallel interface:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 14 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder CE with synchronous-serial interface:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 15 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder CE with incremental-serial interface:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 16 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder CE MLD (without version V001) with cam
switch:
The following functions are only available for the encoder CE MLD (without version V001) with cam
switch with 8 cams:
The following functions are available for the encoder CE MLD (without version V001) with cam
switch and 8 or 18 cams:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 17 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder LA with parallel interface:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 18 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder LA with synchronous-serial interface:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 19 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder LA with incremental-serial interface:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 20 of 68
Operating instructions PT100N ELECTRONIC GmbH
The following functions are available for the encoder LA with cam switch:
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 21 of 68
Operating instructions PT100N ELECTRONIC GmbH
The user is informed about the encoder currently connected or for which encoder type the data loaded
are valid.
The user is informed about the data interface which is used by the connected encoder and which
interfaces support the data loaded.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 22 of 68
Operating instructions PT100N ELECTRONIC GmbH
Two output modes are pre-defined for the encoder CE with synchronous-serial interface (SSI) and
can be selected with the cursor keys.
Select between :
- Left binding or
- Tree format
When left binding is selected the data transfer starts with the most significant bit according to the
number of data bits set later. There are no limitations with this setting.
When tree format is selected no gear can be realized as the data will be output symmetrically. This
requires later for the measuring length parameters the setting in power of two.
Notice:
In the tree format only power of two can be used for the number of revolutions and the number of
steps per revolution, where the first 12 bits are always for the number of revolutions. If not all of the 12
bits are required for the revolutions or the number of steps per revolution, the remaining bits are filled
with zeros, so that the position data always consist of at least 24 bits.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 23 of 68
Operating instructions PT100N ELECTRONIC GmbH
The transmit code of the data can be set and selected with the cursor keys for encoders with data
interface.
Select between:
- Binary
- Gray
- BCD *
- Gray-3-Excess
- Shifted Gray **
- Shifted Gray-3-Excess **
Dependent on the encoder type only a part of the mentioned possibilities appears.
Programming Binary:
Output of the data in binary code.
Programming BCD :
Output of the data in BCD-code. The BCD code (Binary Coded Decimal) has a length of 4 bits to
represent one decimal figure (0-9). Therefore always 4 bits are required to transmit units, tens places,
hundred places etc..
Programming Gray :
Output of the data in Gray-code. With the natural Gray-code the change-over from the largest to the
smallest value (0000) is only one bit, e.g. for an encoder with 8 bit (256 steps) the largest value, in
binary notation, is 1000 0000 and the smallest value is 0000 0000. The change-over is one bit
Programming Gray-3-Excess" :
Output of the data in Gray Excess 3 code. This code is often used in arithmetic units which do not
calculate with the dual system but with the decimal system. Arithmetic operations, addition and
subtraction can be carried out with a minimum of logic operations.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 24 of 68
Operating instructions PT100N ELECTRONIC GmbH
For SSI encoders (with the option transmit repetition) there is the possibility of a multiple data transfer
by continued transmission of the clock pulse. In order to activate this option it must be selected from
the menu.
Select between:
If SSI with repetition is selected, the SSI data are repeated after 26 clock pulses.
A break of more than 25 !s interrupts the repetition mode. Actual data are transmitted with the next
request which then can be repeated as well.
If SSI without repetition is selected, zero bits are output after the last data bit (special bit).
Notice:
It merely seems that a data transfer with repetition increases the data integrity. As disturbances may
occur not only for data but also for clocking lines during the SSI transmission, there is the possibility
that the pulse will be disturbed already after the first pulse transmission. This causes the output of an
additional data bit.
As the following packet of data depends in time from the previous one (in case of transmission with
repetition), it is deferred too. The most unfavorable case is that two identical but disturbed packets of
data are transmitted.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 25 of 68
Operating instructions PT100N ELECTRONIC GmbH
Changing between the output logic, that means between high active or low active is possible for
encoders CE with parallel interface.
Select between:
For certain applications an inverted output of the data can be necessary. This is called negative or
positive logic. Whether the encoder outputs the data accordingly is defined with this selection.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 26 of 68
Operating instructions PT100N ELECTRONIC GmbH
The data interface can be activated permanently or dependent on the bus-input for encoders with
parallel interface and the option "Bus compatible".
Select between:
To transmit the position of several encoders with parallel interface in the multiplex operation via
common data lines, the outputs of the users not inquired must be high-impedance. The data outputs
of the inquired user must be activated only. To operate an encoder with this option without an
additional wiring the bus function is switched off with „Always active ".
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 27 of 68
Operating instructions PT100N ELECTRONIC GmbH
For encoders with parallel interface there are several possibilities to synchronize the data
acceptance.
Select between:
Programming "Continue":
New data are constantly transmitted to the output. The user must ensure that the data are valid. E.g.
asynchronous read-out: The customer electronics reads out the output value (e.g.) three times. Two
values must be identical, one value is rejected.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 28 of 68
Operating instructions PT100N ELECTRONIC GmbH
Select between:
With value and sign, the MSB of the data is taken as sign. For positive data the MSB is low, for
negative data the MSB is high.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 29 of 68
Operating instructions PT100N ELECTRONIC GmbH
In addition to the partly available hardware change-over the count direction can be changed for all
encoders by programming the encoder.
Notice:
For encoders with option "External forward/backward" the programmed count direction is inverted.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 30 of 68
Operating instructions PT100N ELECTRONIC GmbH
3.3.1.11 Offset
Start of the counting can be shifted optional, except for cam switch with 18 cams.
Select between:
- No no offset
- Symmetrical with sign symmetrical offset
- Free Offset with free value possible.
If positive data are to be output by the encoder only, starting with zero, "no offset" has to be
programmed. Start with zero after an overflow.
"Symmetrical offset" is a special case of "Free offset". The programmable gear is divided in two and
arranged at the right and left of the central line. After a positive overflow counting continuous in the
negative range and vice versa.
If the programmable gear must be asymmetrical in the maximum possible range, "Free offset" is set.
The origin can be defined for any point in the area.
Range of values:
BINARY / GRAY
neg. final value pos. final value max. programmable gear
without offset --- 16777215 16777216
with offset -8388607 8388607 16777215
BCD
neg. final value pos. final value max. programmable gear
without offset --- 999999 1000000
with offset -799999 799999 1599999
3-Excess
neg. final value pos. final value max. programmable gear
without offset --- 999999 1000000
with offset -799999 799999 1599999
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 31 of 68
Operating instructions PT100N ELECTRONIC GmbH
All encoders, if option "External preset" is available, can be set to a defined position value by an input
signal. If this function is not installed or will not be used, it must be switched off in order to avoid
malfunctions or maloperation.
Select between:
With active preset function the encoder is programmed with a new position, after the external input
changed from low to high and an internal time control expired. This process lasts some time as the
complete position parameters must be recalculated and stored in a memory which is safe from data
loss.
If the input is reset during the time control, the preset request is rejected.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 32 of 68
Operating instructions PT100N ELECTRONIC GmbH
For best adaptation of the encoder to the application condition the binary position data can be
converted already in the encoder.
Select between:
Notice:
The total capacity (Steps / length) of the encoder consists of the steps per revolution (0-360°) and the
number of revolutions. For angular measurements within 360° one turn is needed = Singleturn. For
displacement measurements 2-4096 (power of two) or 1-126976 (optional) revolutions = Multiturn are
required depending on the distance.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 33 of 68
Operating instructions PT100N ELECTRONIC GmbH
A programmable gear is defined in "Steps / length " and "revolutions". The number of revolutions is
defined by the mechanics. The number of the total steps results from the desired resolution or the
representation mode of the distance.
An editing function is concerned here, that means a numerical value is entered here.
If the parameter „gear“ was previously selected for „programmable gear ", two kinds of possible
entries appear here. Non-integer revolution ratios are perhaps required for a gear. Therefore the
revolutions are entered as fraction. The numerator is entered first and then the denominator of the
fraction.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
If "Gear" was selected, a number between 1 and 126976 can be entered. If the "Programmable gear
in revolutions" is programmed as fracture, the nominator must not be larger than 126976.
When "Unlimited" was selected a number in power of two between 2 and 4096 can be entered. Other
values are rounded off to the next lower power of two.
In most of the applications the "Revolutions" are programmed in power of two. If e.g. 410 revolutions
are required, the next higher power of two 512 must be programmed.
For certain applications, e.g. rotary tables, tool changer etc. encoder systems for integer values are
needed.
Notice:
For freely selectable encoder systems the encoder must not be turned further than 512 revolutions
maximum while it is in dead condition. Turning more than 512 revolutions may cause a lost of the
adjustment value (preset value). Therefore it is recommended to program the next higher power of two
than the calculated number of revolutions for distance measurement.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 34 of 68
Operating instructions PT100N ELECTRONIC GmbH
e.g. 4096 steps per revol. x 4096 revol..: max. meas. length = 16777216.
1024 steps per revol. x 4096 revol. : max. meas. length = 4194304
The following formula applies for the scaling parameters for an encoder:
For the distance mode "Gear" the "Number of revolutions per length" is programmed as fraction!
The following formula applies for the scaling parameters for a LA encoder:
The resolution of the rod is set by the Steps / length. The measuring length/S results from the
measuring length indicated on the rod and the desired resolution.
Example:
Measuring length rod [mm] = 500, resolution = 0,01mm, measuring length [steps] = 50 000
Measuring length rod [mm] = 500, resolution = 0,1mm, measuring length [steps] = 5000
Note:
With the LA-NSW the displayed measuring length in steps is without meaning. The scaling is effected
with the correction value see chapter "Correction value", page 44.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 35 of 68
Operating instructions PT100N ELECTRONIC GmbH
If an offset was selected, the respective value can be entered here. The corresponding values have
already been calculated for "symmetrical offset", changing them later is possible but than the setting
"symmetrical offset" will be changed in "free offset".
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
Range of values:
BINARY / GRAY
neg. end value pos. end value max. measuring length
without displacem. --- 16777215 16777216
with displacement -8388607 8388607 16777215
BCD
neg. end value pos. end value max. measuring length
without displacem. --- 999999 1000000
with displacement -799999 799999 1599999
3-Excess
neg. end value pos. end value max. measuring length
without displacem --- 999999 1000000
with displacement -799999 799999 1599999
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 36 of 68
Operating instructions PT100N ELECTRONIC GmbH
The corresponding values can be entered here with the numerical keys.
If the value displayed is correct it can be confirmed with the Enter key.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
After the corresponding input changed from Low to High for released preset inputs and is active long
enough (internal time control), the new position value entered here appears on the data lines. The
encoder calculates its new zero point and saves the data in a memory secured against data loss. This
proceeding takes some milliseconds.
Notice:
Please take care that the preset values are not out of the used area. Preset values out of the area are
corrected automatically and displayed.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 37 of 68
Operating instructions PT100N ELECTRONIC GmbH
Depending on the encoder used, one or two limit switches or static cams regardless of a cam switch
function are supported. As special function one or two remaining data bits can be assigned to this
area function.
The start positions of the areas can be entered here with the numerical keys.
If the value displayed is correct it can be confirmed with the Enter key.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
Notice:
Please take care that the values are not out of the used area. Values outside the area are corrected
automatically and displayed.
Area1 and Area2 were named safety range and operating range in the previous versions.
There is no assignment below and above the area for EPROG encoders but only outside or within the
area.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 38 of 68
Operating instructions PT100N ELECTRONIC GmbH
Depending on the encoder used, one or two limit switches or static cams regardless of a cam switch
function are supported. As special function one or two remaining data bits can be assigned to this
area function.
The end positions of the area can be entered here with the numerical keys.
If the value displayed is correct it can be confirmed with the Enter key.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
Notice:
Please take care that the values are not out of the used area. Values outside the area are corrected
automatically and displayed.
Area1 and Area2 were named safety range and operating range in the previous versions.
There is no assignment below and above the area for EPROG encoders but only outside or within the
area.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 39 of 68
Operating instructions PT100N ELECTRONIC GmbH
The number of data bits appears on the display. The value can be taken over or changed.
Position bits are digitized angular positions or distances which are available at the outputs as code
word. 16 outputs are usually assigned for position data. The minimum number of data bits further
depends on the Steps / length and the code used and may change. If an attempt is made to program
a smaller value than required, the correct minimum value appears automatically. It now can be
increased or taken over.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 40 of 68
Operating instructions PT100N ELECTRONIC GmbH
For SSI encoders special information can be added to the position data within the 31-bit data word
during the data transfer.
- 1 = OUT OF RANGE Magnet at the top of the rod is out of measuring range
- 0 = OUT OF RANGE Magnet at the top of the rod is out of measuring range
Notice:
For encoders with the programming possibility SSI with repetition only 6 special bits in the data stream
are available. The special bits 7. ... 8. are always zero for a synchronous-serial transmission. They are
wired on the connector as hardware outputs instead.
The special functions are possible for all bits, which are not assigned for data bits.
Programming of the special bits 1. ... 6. and hardware outputs 1. ... 2. is done like for previous
encoder designs with the special bits 1. ... 8. .
For data transfer in tree format the special bits are sometimes used to fill the signal with zero until 24
bits are reached. These special bits are automatically assigned to "logical 0" and cannot be changed.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 41 of 68
Operating instructions PT100N ELECTRONIC GmbH
For encoders with parallel interface special information can be added for outputs not used.
- 1 = OUT OF RANGE Magnet at the top of the rod is out of measuring range
- 0 = OUT OF RANGE Magnet at the top of the rod is out of measuring range
Notice:
The low-significant outputs are assigned with the position data and a sign, if necessary, according to
the number of data bits programmed.
Example: If the number of data bits is 21, the 21. output is the LSB bit or the sign.
"0/1=Dt. valid" can be selected for an output only if the data output was programmed with "Strobe".
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 42 of 68
Operating instructions PT100N ELECTRONIC GmbH
Encoders with an incremental serial interface normally supply information to counting modules.
These modules have a maximum input frequency.
To avoid exceeding of this frequency the corresponding value can be entered in kilohertz here. The
maximum possible value is 125 kHz
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 43 of 68
Operating instructions PT100N ELECTRONIC GmbH
Adaptation of linear position sensing systems with older design, installed in the actual system, is
possible with a correction value.
For example:
The correction value is determined and programmed by TR Electronic. This value differs for each
linear transducer with older design. This value is the reference between distance and indicated steps.
In order to change the resolution of the rod the correction value must be reprogrammed accordingly.
Notice:
A 1 as correction value must not be changed.
For linear position sensing systems with soft-no. 50xx.xx the correction value is irrelevant and cannot
be entered.
With the LA-NSW the scaling is effected further with the correction value. The correction value may be
max. six digits.
It corresponds:
0.999 999 = Resolution 0.01 mm
0.100 000 = Resolution 0.1 mm
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 44 of 68
Operating instructions PT100N ELECTRONIC GmbH
A slave display, connected to the same interface as the PT100N is supported by all encoders, except
the CE-MLD (without version V001) cam switch with 18 cams.
The display type is saved in the device and not in the display. The corresponding parameters are set
with the PT100N.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 45 of 68
Operating instructions PT100N ELECTRONIC GmbH
For an optimum adaptation of the display to the programmable gear the data can be output in decimal
point presentation.
Select between:
- no decimal point
- 1 decimal point
- 2 decimal points
- 3 decimal points
- 4 decimal points
With the display the position data can be recalculated and displayed in another way than with the
encoder. Set the parameter display position first.
Select between:
- same programme
- new scaling
3.3.2.3 Signs
If new scaling was selected for the position display, the sign can be changed here.
Select between:
- same programme
- inverted
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 46 of 68
Operating instructions PT100N ELECTRONIC GmbH
If new scaling was selected for the position display, the step number to which new scaling of the
encoder is to be carried out, can be entered here with the numerical keys.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
If new scaling was selected for the position display, origin to which new scaling of the programmable
gear is to be carried out can be entered here with the numerical keys.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 47 of 68
Operating instructions PT100N ELECTRONIC GmbH
Operate and release points of the individual cams can be entered here with the numerical keys.
Wrong entries can be corrected with the key CE. Use F3 to go back in single steps. When the value is
entered correctly, confirm with the Enter key.
Use F4 for a TEACH IN function for each point. Confirm with the enter key if the indicated position
shall be taken.
A later editing is possible. Confirm the value with the enter key.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 48 of 68
Operating instructions PT100N ELECTRONIC GmbH
The advantage is, that data can be copied from one encoder to another encoder of the same design
using the PT100N.
If a data difference occurred a storage address and the corresponding storage contents is indicated
on the display. This value cannot be interpreted and will be used only to indicate whether it changes
with repeated error.
In case of a data difference it is recommended to read in the data again and to compare them with the
edit function. The problem should be eliminated after saving the data once again.
Notice:
With EPROG encoders the data verification can lead to another error message because of different
internal checks. Read data again and check in the EDIT MENU.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 49 of 68
Operating instructions PT100N ELECTRONIC GmbH
The current position appears on the display and can be modified with the numerical keys. The
encoder gets the new position after the Enter key has been pressed.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 50 of 68
Operating instructions PT100N ELECTRONIC GmbH
The encoder currently connected or for which type the data currently loaded are valid, is indicated
here for the information of the user,.
The number of physical revolutions, which can be counted a the most, are indicated here.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 51 of 68
Operating instructions PT100N ELECTRONIC GmbH
The number of physical steps per revolution (resolution), which can be counted a the most, are
indicated here .
The data interface available for the encoder currently connected or supported by the data currently
loaded, is indicated here for the information of the user.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 52 of 68
Operating instructions PT100N ELECTRONIC GmbH
Francais
Article-no.: 480-00020/V001
Francais
German
English
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 53 of 68
Operating instructions PT100N ELECTRONIC GmbH
A password must be entered to get to the corresponding functions. The password is simply 8888.
The following functions are inquiry routines only. Modifications are not possible.
Changeable encoder parameters are called ROM data. The main parameters and the corresponding
storage addresses are indicated in Hex format.
Unchangeable encoder parameters are called RAM data. The operating parameters and the
corresponding storage addresses are indicated in Hex format.
The first eight addresses are the not-adjusted position and the internal zero point. They are read in
permanently and vary with each change of the position and adjustment process.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 54 of 68
Operating instructions PT100N ELECTRONIC GmbH
The key operated is indicated on the display. Keyboard ok appears if all keys have been pressed and
recognized.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 55 of 68
Operating instructions PT100N ELECTRONIC GmbH
In this context, you should consider the PT100's usability as a subset of the options provided by the
EPROG PC program.
If the EPROG PC program switches a Version 001 encoder (refer to the rating plate) to PT100-
compatible mode, the extended functions are no longer available.
PT100 programming is also no longer available if you chose the complete range of functions.
In this case, the PT100N cannot connect to the encoder; up to now, programming was not possible in
this way.
The new EPROG-DIALOG menu item makes it possible to switch to this option: this was previously
only possible using the PC.
This means that a PT100N of Version 2.1a and above can switch an EPROG encoder that was not
programmed by a PT100N to PT100-compatible mode.
Important!
When you choose this menu item, the current setting of the encoder is shown. You can only choose
interfaces that are actually fitted on the device.
If, for example, you choose an encoder that only has an SSI interface fitted as a parallel device, the
corrected setting No is shown on the display.
If you confirm this setting, PT100-compatible mode is switched off, i.e. data cannot be ready any
longer. In this case, you must choose the EPROG-DIALOG again and set the option that matches the
interface.
When switching operating modes, data may be changed. In any case, you should carry out complete
reprogramming.
In the case of devices with several interfaces, it is possible to make several settings. This means that
you can individually set every interface.
However, all the installed interfaces have a common effect on the switching outputs, i.e. they influence
one another. In this case, it is advisable not to use switching outputs.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 56 of 68
Operating instructions PT100N ELECTRONIC GmbH
4 Appendix
4.1 Programming examples
The following example shows which values and parameters are to be programmed for the assumed
task. Programming itself is described in the chapter "Edit encoder".
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 57 of 68
Operating instructions PT100N ELECTRONIC GmbH
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 58 of 68
Operating instructions PT100N ELECTRONIC GmbH
A tool changer with 100 tools shall stop at the 1. tool after Code BCD - Code
one revolution of the encoder. Output logic 0V = LOW
The encoder must transmit the output data in BCD - Code
Data bus active always active
from 1 to 100. (The start of the measurement must be
shifted by one step. Instead of 0 - 99 thedata shall be Data transfer Dyn. Strobe
transmitted from 1 - 100.) Count direction increas. clockwise.
The encoder shall be connected to a data bus. (Encoder
switched on, active, with 0V at the BUS input). Offset free
The output data must be available as pos. logic. preset function not in use
Further the encoder must provide a control bit (odd parity).
Meas. distance gear
A slave display is not required.
The adjustment of the encoder is not carried out with the Meas. length/ R. 27
preset inputs but with the PT100N. Counter
Calculation of the measuring length /U.:
Meas. length in steps = 100 Meas. length / R. 20
Rotary factor = 1:1,35 Denominator
The value 1:1,35 must now be converted into a divisible Meas. length/ S. 100
numerical ratio below the value 100.
Start of meas. 1
1,35 135 27 Pos. Preset 1 1
= =
1 100 20 Pos. Preset 2 1
Start area 1 2
Enter the value 27 decimal point 20 in the range meas.
length/R. 27/20 appears on the display. Start area 2 2
The encoder now delivers the values 1 to 100 and returns End area1 2
to value 1 after 1,35 revolutions.
End area2 2
No. Pos. Bits 16
17. Output Odd Parity
18. Output 0 = invalid data
19. Output statical 0
20. Output statical 0
21. Output statical 0
22. Output statical 0
23. Output statical 0
24. Output statical 0
Display type no decimal point
TA : Pos. display same program
TA : Sign display same program
TA : Step number 100
TA : start of meas. 1
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 59 of 68
Operating instructions PT100N ELECTRONIC GmbH
Diagram 1:
S ig n a l c o u rs e a t th e c o n tro l
C y c le +
( m a x . 3 2 p u ls e s )
D a ta tra n s m is s io n
( n o r m a l p o la r ity )
MSB LSB
tM
D a t a t r a n s m is s io n
(p o la rity
in t e r c h a n g e d ) MSB LSB
tM
Monoflop time tM is set to 20 µs and determines the lowest transmission frequency of approx. 50 kHz.
The upper limit frequency is determined by the sum of the time control and is approx. 1,1 MHz.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 60 of 68
Operating instructions PT100N ELECTRONIC GmbH
Diagram 2 (5 examples):
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Z
Z 2
12 4096 1 1 11
2 2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0 11
2
10
2 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
S1 4096
11 2048 1 1 0 2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0 10
2 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 S2 2048
10 1024 1 1 0 0 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 0 S3 1024
9 512 1 1 0 0 0 2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 0 0 S4 512
8 256 1 1 0 0 0 0 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 0 0 0 S5 256
Cycle + Notice:
25 26 27 28 29 30 31 32
Special bit 7 and 8 are available as
parallel outputs, but must be
Example 1 S1 S2 S3 S4 S5 S6 0 0
assigned to the connector!
Example 2 S2 S3 S4 S5 S6 0 0 0
Example 3 S3 S4 S5 S6 0 0 0 0
Example 4 S4 S5 S6 0 0 0 0 0
Example 5 S5 S6 0 0 0 0 0 0
S = special bit
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 61 of 68
Operating instructions PT100N ELECTRONIC GmbH
Diagram 3: Example for synchronous serial data transfer without tree format
Cycle +
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Example 1 1 1 0 0 0 0
19
2
18
2
17
2
16
2
15
2
14
2
13
2
12
2
11
2
10
2 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
S1
Example 2 1 1 16
2
15
2
14
2
13
2
12
2
11
2
10
2 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
S1 S2 S3 S4 S5 S6 0 0
Example 3 1 1 0 0
21
2
20
2
19
2
18
2
17
2
16
2
15
2
14
2
13
2
12
2
11
2
10
2 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
S1
Example 4 1 1 18
2
17
2
16
2
15
2
14
2
13
2
12
2
11
2
10
2 2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
S1 S2 S3 S4 S5 S6
Cycle + Notice:
25 26 27 28 29 30 31 32
Special bit 7 and 8 are available as
parallel outputs, but must be
Example 1 S1 S2 S3 S4 S5 S6 0 0
assigned to the connector!
Example 2 0 0 0 0 0 0 0 0
Example 3 S1 S2 S3 S4 S5 S6 0 0
Example 4 S6 0 0 0 0 0 0 0
S = special bit
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 62 of 68
Operating instructions PT100N ELECTRONIC GmbH
Number of leading zeros 4, number of data bits to be programmed 24, number of special bits to be
programmed 8
Number of leading zeros non, number of data bits to be programmed 17, number of special bits to be
programmed 8
Number of leading zeros 2, number of data bits to be programmed 24, number of special bits to be
programmed 8
Number of leading zeros none, number of data bits to be programmed 19, number of special bits to be
programmed 8
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 63 of 68
Operating instructions PT100N ELECTRONIC GmbH
Index
B
Bus functions; CE/LA parallel...............................................................................................................27
C
Cams ....................................................................................................................................................48
Output special information....................................................................................................................42
Comple LA............................................................................................................................................29
Correction value; LA .............................................................................................................................44
Count direction .....................................................................................................................................30
D
decimal point presentation; TA-MINI ....................................................................................................46
Display data interface ...........................................................................................................................22
Display test ...........................................................................................................................................55
E
Encoder adjustment....................................................................................................................... 32, 37
Encoder reference point .......................................................................................................................36
Encoder type ........................................................................................................................................22
Encoder type ........................................................................................................................................51
End area; (Limit switch function) ..........................................................................................................39
F
Functions CE; (8 cams) ........................................................................................................................17
Functions CE; (8/18 cams)...................................................................................................................17
Functions CE; Cam switch ...................................................................................................................17
Functions CE; incremental serial..........................................................................................................16
Functions CE; parallel ..........................................................................................................................14
Functions CE; synchronous-serial .......................................................................................................15
Functions LA; Cam switch....................................................................................................................21
Functions LA; incremental-serial ..........................................................................................................20
Functions LA; parallel ...........................................................................................................................18
Functions LA; synchronous-serial ........................................................................................................19
K
Keyboard assignment.............................................................................................................................9
Keyboard test .......................................................................................................................................55
M
Max. steps/revol. ..................................................................................................................................52
Maximum number of revolutions ..........................................................................................................51
Measuring length ..................................................................................................................................35
Menu "Adjustment" ...............................................................................................................................50
Menu "Edit" ...........................................................................................................................................12
Menu "Language" .................................................................................................................................53
Menu "Main parameters" ......................................................................................................................51
Menu "Read" ........................................................................................................................................11
Menu "Save" .........................................................................................................................................49
Menu "Service" .....................................................................................................................................54
Menu "Verify data"................................................................................................................................49
Menu chart..............................................................................................................................................8
Multiplex transmission; CE synchronous serial....................................................................................25
O
Operation PT 100 N................................................................................................................................9
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 64 of 68
Operating instructions PT100N ELECTRONIC GmbH
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 65 of 68
Operating instructions PT100N ELECTRONIC GmbH
Glossary
A
Absolute encoder Optical rotary position sensing system. The delivered measured value
is the complete analogue or digital position. If the encoder is
moved mechanically while the encoder is switched off, the current
position can be read out immediately after switching on the power
supply.
B
Bus Common transmission channel to which all users are connected;
has two defined ends.
C
CE Absolute encoder, programmable with the programming terminal
PT100N or with the programming software "EPROG".
(2) complement Representation mode for negative binary numbers. In the two's
complement representation a positive number is marked by a 0 in the
most significant place and a negative number is marked by a 1.
D
Data interface Encoder with parallel or synchronous serial interface; the data
(referred to this operating manual) are transmitted in a certain code
Dynamical strobe The encoder supplies a special signal (dyn. strobe). The signal
indicates, when the output data can be read out or not.
E
"EPROG" PC-Parameterization software for programmable CE or LA encoders.
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 66 of 68
Operating instructions PT100N ELECTRONIC GmbH
H
HEX-Dump Memory dump (Hexadecimal format)
I
ISI Incremental serial interface for absolute encoders.
Position changes are transmitted by two incremental tracks.
L
Latch The output data can be "frozen in" via the latch function. The user's
electronics reads a statical value without edge transitions.
Limit switch Switch output which is set after a certain condition is fulfilled
(programmable).
M
Monoflop Mono-stable multivibrator; a trigger pulse at the input generates
a single pulse at the output. The duration of the output signal does
not depend on the input pulse.
Multiturn Encoder which does not only resolve the number/revolutions, but can
also acquire multiple revolutions.
Multiplex operation Operation of several encoders. Position transfer via common data
lines (see also bus).
N
NSW Cam switch
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 67 of 68
Operating instructions PT100N ELECTRONIC GmbH
O
Out of range The magnet is at the top of the rod, out of measuring range;
for LA encoders only
P
Position bits Digitized angular positions or distances, available as code word at
the outputs (see also code).
Preset The output data of the encoder are set to the programmed value
when activating this input (adjustment between mechanics and
electronics).
R
RAM Random-Access-Memory
ROM Read-Only-Memory
S
SSI Synchronous serial interface for absolute encoders.
T
Tree format Data transfer format for a synchronous serial interface (see also
chapter "SSI Output tree format ")
TR - ELECTRONIC GmbH, Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. 07425-228-0, Fax 07425-228-33
Date: 03.09.2002 TR - E - BA - GB - 0012 - 03 Page 68 of 68