0% found this document useful (0 votes)
25 views20 pages

TPbin A1e5c

The document discusses the importance of constructing grout curtains in dams. It introduces the geology of the Karun 3 project site and the grout curtains used in this project. It then summarizes the results obtained so far from drilling and grouting operations (as of the time of writing) in the grout curtains of this project. Specifically, it provides more details and analysis of galleries 795 and 850 on the left bank where more information was available.

Uploaded by

baqerahmadi22
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views20 pages

TPbin A1e5c

The document discusses the importance of constructing grout curtains in dams. It introduces the geology of the Karun 3 project site and the grout curtains used in this project. It then summarizes the results obtained so far from drilling and grouting operations (as of the time of writing) in the grout curtains of this project. Specifically, it provides more details and analysis of galleries 795 and 850 on the left bank where more information was available.

Uploaded by

baqerahmadi22
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

‫‪www.civilbook.

ir‬‬
‫‪Main Menu‬‬

‫" ﺑﺮﺭﺳﻲ ﻧﺘﺎﻳﺞ ﺗﺰﺭﻳﻘﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺩﺭ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺳﺪ ﻭ ﻧﻴﺮﻭﮔﺎﻩ ﻛﺎﺭﻭﻥ ‪" ٣‬‬

‫‪١‬‬
‫ﻏﻼﻣﻌﻠﻲ ﻛﺎﺷﻜﻲ‬

‫ﭼﻜﻴﺪﻩ ‪:‬‬
‫ﺩﺭ ﺍﻳـﻦ ﻣﻘﺎﻟـﻪ ﺳـﻌﻲ ﺷﺪﻩ ﺍﺳﺖ ﺍﺑﺘﺪﺍ ﺑﻪ ﺍﻫﻤﻴﺖ ﺍﺣﺪﺍﺙ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺩﺭ ﺳﺪﻫﺎ ﻭﺍﻧﻮﺍﻉ ﺭﺍﻳﺞ ﺍﻧﻬﺎ ﺍﺷﺎﺭﻩ ﺷﻮﺩ ‪ ،‬ﺳﭙﺲ ﺑﻪ ﻣﻌﺮﻓﻲ ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ‬
‫ﺳﺎﺧﺘﮕﺎﻩ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ ٣‬ﻭ ﭘﺮﺩﻩ ﻫﺎﻱ ﺍﺑﺒﻨﺪ ﻣﻮﺟﻮﺩ ﺩﺭ ﺍﻳﻦ ﭘﺮﻭﮊﻩ ﭘﺮﺩﺍﺧﺘﻪ ﺷﻮﺩ ﻭ ﺩﺭ ﻧﻬﺎﻳﺖ ﻧﺘﺎﻳﺞ ﺑﺪﺳﺖ ﺍﻣﺪﻩ ﺍﺯ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ‬
‫ﺍﺟﺮﺍ ﺷﺪﻩ ) ﺗﺎ ﺯﻣﺎﻥ ﺗﻬﻴﻪ ﻣﻘﺎﻟﻪ( ﺩﺭ ﭘﺮﺩﻩ ﻫﺎﻱ ﺍﺑﺒﻨﺪ ﺍﻳﻦ ﭘﺮﻭﮊﻩ ﺑﻪ ﺍﮔﺎﻫﻲ ﺭﺳﺎﻧﺪﻩ ﺷﻮﺩ ﻻﺯﻡ ﺑﻪ ﺫﻛﺮ ﺍﺳﺖ ﻛﻪ ﺳﻌﻲ ﺷﺪﻩ ﺍﺳﺖ ﺩﺭ ﺑﺨﺶ ﻫﺎﻳﻲ‬
‫ﺍﺯ ﭘـﺮﺩﻩ ﺍﺑﺒـﻨﺪ ﻫﻤﺎﻧﻨﺪ ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٧٩٥‬ﻭ ‪ ٨٥٠‬ﺩﺭ ﺳﺎﺣﻞ ﭼﭗ ﻛﻪ ﺍﻃﻼﻋﺎﺕ ﺑﻴﺸﺘﺮﻱ ﺍﺯ ﺍﻧﻬﺎ ﺩﺭ ﺍﺧﺘﻴﺎﺭ ﺑﻮﺩﻩ ﺍﺳﺖ ﺑﺎ ﺟﺰﺋﻴﺎﺕ ﺑﻴﺸﺘﺮﻱ‬
‫ﻣﻮﺭﺩ ﺑﺮﺭﺳﻲ ﻭ ﺗﺠﺰﻳﻪ ﻭ ﺗﺤﻠﻴﻞ ﻗﺮﺍﺭ ﺑﮕﻴﺮﺩ‪.‬‬

‫‪١‬ﺳﺮﭘﺮﺳﺖ ﻛﺎﺭﮔﺎﻩ ﮊﺋﻮﺗﻜﻨﻴﻚ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ – ٣‬ﺷﺮﻛﺖ ﺳﺎﺑﻴﺮ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٦٥‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﻣﻘﺪﻣﻪ ‪:‬‬
‫ﻫـﺪﻑ ﺍﺯ ﺍﺭﺍﺋـﻪ ﺍﻳـﻦ ﻣﻘﺎﻟـﻪ ﺗﻼﺵ ﺩﺭ ﺟﻬﺖ ﻣﻌﺮﻓﻲ ﭘﺮﺩﻩ ﻫﺎﻱ ﺍﺑﺒﻨﺪ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ ٣‬ﻭ ﻧﺘﺎﻳﺞ ﺑﺪﺳﺖ ﺍﻣﺪﻩ ﺗﺎ ﻛﻨﻮﻥ ﺍﺯ ﻋﻤﻠﻴﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ‬
‫ﺟﻬـﺖ ﻣﻌﺮﻓـﻲ ﺑـﻪ ﻣﺘﺨﺼﺼـﻴﻦ ﺍﻣﺮ ﻣﻲ ﺑﺎﺷﺪ ﻭ ﺍﻣﻴﺪﻭﺍﺭﻡ ﻣﻨﺠﺮ ﺑﻪ ﺍﺭﺍﺋﻪ ﺭﺍﻩ ﻛﺎﺭﻫﺎﻱ ﻣﻔﻴﺪ ﻭ ﻣﻮﺛﺮ ﺍﻳﺸﺎﻥ ﺩﺭ ﺯﻣﻴﻨﻪ ﺳﺎﺯﻱ ﺍﺣﺠﺎﻡ ‪ ،‬ﺭﻭﺵ ﻫﺎﻱ‬
‫ﺍﺟﺮﺍﻳﻲ ﻭ ﻃﺮﺍﺣﻲ ﻫﺎﻱ ﻣﻮﺟﻮﺩ ﺷﻮﺩ ‪.‬‬

‫ﺑﺨﺶ ﻫﺎﻱ ﺍﺻﻠﻲ ﻣﻘﺎﻟﻪ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﺍﺭﺍﺋﻪ ﻣﻲ ﮔﺮﺩﻧﺪ ‪:‬‬

‫‪ -١‬ﺍﻫﻤﻴﺖ ﺍﺣﺪﺍﺙ ﭘﺮﺩﻩ ﺗﺰﺭﻳﻖ ﺍﺑﺒﻨﺪ ﺩﺭ ﺳﺪﻫﺎ ‪:‬‬


‫ﺍﻳﺠـﺎﺩ ﭘـﺮﺩﻩ ﺗـﺰﺭﻳﻖ ﺑﺨـﺶ ﺯﻳـﺎﺩﻱ ﺍﺯ ﺗﺮﻣـﻴﻢ ﻭ ﺑﻬﺴـﺎﺯﻱ ﭘـﻲ ﻫـﺎ ﺭﺍ ﺑـﻪ ﺧﻮﺩ ﺍﺧﺘﺼﺎﺹ ﻣﻴﺪﻫﺪ ﻛﻪ ﻫﺪﻑ ﺍﺯ ﺍﺟﺮﺍﻱ ﺍﻥ ﺍﻳﺠﺎﺩ ﺣﺎﺋﻠﻲ ﺑﺎ‬
‫ﺍﺑﮕـﺬﺭﻱ ﻛـﻢ ﻭ ﻗـﺎﺑﻞ ﻛﻨـﺘﺮﻝ ﻭ ﺍﻗﺘﺼـﺎﺩﻱ ﺩﺭ ﻣﺴـﻴﺮ ﻣﺤﻮﺭ ﺳﺪ ﻭ ﺗﻜﻴﻪ ﮔﺎﻫﻬﺎﻱ ﺍﻥ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺑﺪﻳﻦ ﺗﺮﺗﻴﺐ ﻛﻪ ﺑﻌﺪ ﺍﺯ ﺍﺑﮕﻴﺮﻱ ﻣﺨﺰﻥ ‪ ،‬ﭘﺮﺩﻩ‬
‫ﺗـﺰﺭﻳﻖ ﺍﻳﺠـﺎﺩ ﺷـﺪﻩ ﻫﻤﺎﻧـﻨﺪ ﻳـﻚ ﺳـﭙﺮ ﻫﻴﺪﺭﻭﻟﻴﻜﻲ ﺑﺎ ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﻛﻢ ) ﺣﺪﺍﻗﻞ( ﻭ ﻋﻤﻮﻣﺎ" ﺑﺎ ﺷﻴﺐ ﺑﻪ ﻃﺮﻑ ﺑﺎﻻ ﺩﺳﺖ ) ﺳﺮﺍﺏ( ﺩﺭ ﺑﺮﺍﺑﺮ‬
‫ﺟـﺮﻳﺎﻥ ﺍﺏ ﺩﺭ ﺯﻳـﺮ ﺑﺪﻧـﻪ ) ﭘﻲ ( ﻭ ﺗﻜﻴﻪ ﮔﺎﻩ ﻫﺎﻱ ﺳﺪ ﻋﻤﻞ ﻣﻲ ﻛﻨﺪ ﻭ ﺑﺎ ﻃﻮﻻﻧﻲ ﻧﻤﻮﺩﻥ ﻣﺴﻴﺮ ﺟﺮﻳﺎﻥ ﺑﺎﻋﺚ ﺍﺳﺘﻬﻼﻙ ﺍﻧﺮﮊﻱ ﺟﺮﻳﺎﻥ ﺍﺏ ﻭ‬
‫ﻛـﺎﻫﺶ ﻗـﺎﺑﻞ ﻣﻼﺣﻈـﻪ ﻧﺸـﺖ ﺧﻮﺍﻫﺪ ﺷﺪ ‪ .‬ﻛﻪ ﺍﻳﻦ ﺧﻮﺩ ﻣﻮﺟﺐ ﺍﻳﻤﻨﻲ ﻭ ﭘﺎﻳﺪﺍﺭﻱ ﺳﺪ ﻭ ﺫﺧﻴﺮﻩ ﻣﻄﻠﻮﺏ ﺍﺏ ﺩﺭ ﻣﺨﺰﻥ ﺳﺪ ﻭ ﺟﻠﻮﮔﻴﺮﻱ ﺍﺯ‬
‫ﻓﺮﺳـﺎﻳﺶ ﺩﺍﺧﻠـﻲ ﻣﺼﺎﻟﺢ ﺗﺸﻜﻴﻞ ﺩﻫﻨﺪﻩ ﭘﻲ ﺧﻮﺍﻫﺪ ﺷﺪ‪ .‬ﺍﻟﺒﺘﻪ ﻣﻌﻤﻮﻻ" ﭘﺮﺩﻩ ﺯﻫﻜﺶ ﻣﻨﺎﺳﺐ ﺩﺭ ﭘﺎﺋﻴﻦ ﺩﺳﺖ ﭘﺮﺩﻩ ﺗﺰﺭﻳﻖ ﺑﻤﻨﻈﻮﺭ ﺟﻠﻮﮔﻴﺮﻱ‬
‫ﺍﺯ ﻓﺸﺎﺭ ﺑﺎﻻ ﺑﺮﻧﺪﻩ ﻭ ﻓﺮﺳﺎﻳﺶ ﺩﺍﺧﻠﻲ ﭘﻲ ﻃﺮﺍﺣﻲ ﻣﻲ ﺷﻮﺩ ‪.‬‬

‫‪ -٢‬ﺍﻧﻮﺍﻉ ﭘﺮﺩﻩ ﺗﺰﺭﻳﻖ ﺍﺑﺒﻨﺪ ﺩﺭ ﺳﺪﻫﺎ‪:‬‬


‫ﭘﺮﺩﻩ ﻫﺎﻱ ﺍﺑﺒﻨﺪ ﺩﺭ ﺳﺪﻫﺎ ﻣﻌﻤﻮﻻ" ﺑﻪ ﺩﻭ ﺩﺳﺘﻪ ﺗﻘﺴﻴﻢ ﻣﻲ ﮔﺮﺩﻧﺪ ﻛﻪ ﻋﺒﺎﺭﺗﻨﺪ ﺍﺯ ‪:‬‬

‫‪ -٢-١‬ﭘـﺮﺩﻩ ﻫـﺎﻱ ﻣﺘﺼـﻞ ﺑـﻪ ﻗﺸـﺮ ﻫﺎﻱ ﻧﺎﺗﺮﺍﻭﺍ ﻭ ﺍﺑﺒﻨﺪ‪ :‬ﺍﻳـﻦ ﭘﺮﺩﻩ ﻫﺎ ﺑﺴﺘﻪ ﺑﻪ ﺷﺮﺍﻳﻂ ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ ﺳﺎﺧﺘﮕﺎﻩ ) ﭘﻲ ‪ -‬ﺗﻜﻴﻪ‬
‫ﮔﺎﻫﻬـﺎﻱ ﺳـﺪ( ﻣﻤﻜـﻦ ﺍﺳـﺖ ﺩﺭ ﭘﻲ ﻭ ﺗﻜﻴﻪ ﮔﺎﻫﻬﺎ ﺑﻪ ﻻﻳﻪ ﻫﺎﻱ ﺑﺎ ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﻛﻢ ﻣﺘﺼﻞ ﮔﺮﺩﻧﺪ ﻛﻪ ﺍﻳﻦ ﺑﺨﺶ ﻫﺎ ﻣﻤﻜﻦ ﺍﺳﺖ ﻻﻳﻪ ﺍﻱ ﺑﺎ‬
‫ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﻛﻢ ﻣﺜﻞ ﻻﻳﻪ ﻫﺎﻱ ﺭﺳﻲ – ﺳﻨﮓ ﻫﺎﻱ ﺷﻴﻠﻲ ﻭﻳﺎ ﻣﺎﺭﻧﻲ ﻭ ﻳﺎ ﻳﻚ ﺳﻄﺢ ﮔﺴﻞ ﺑﺎ ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﻛﻢ ﺑﺎﺷﺪ‪.‬‬

‫‪ -٢-٢‬ﭘﺮﺩﻩ ﺗﺰﺭﻳﻖ ﻣﻌﻠﻖ ‪ :‬ﺩﺭ ﺻﻮﺭﺗﻲ ﻛﻪ ﻟﻴﺘﻮﻟﻮﮊﻱ ﺳﺎﺧﺘﮕﺎﻩ ﺳﺪ ﺑﻨﺤﻮﻱ ﺑﺎﺷﺪ ﻛﻪ ﺍﻣﻜﺎﻥ ﺩﺳﺘﺮﺳﻲ ﺑﻪ ﻳﻚ ﻗﺸﺮ ﻧﻔﻮﺫ ﻧﺎﭘﺬﻳﺮ ﺩﺭ ﻋﻤﻖ‬
‫ﻗﺎﺑﻞ ﺩﺳﺘﺮﺱ ﻧﺒﺎﺷﺪ‪،‬ﻃﺮﺡ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺑﺼﻮﺭﺕ ﭘﺮﺩﻩ ﻣﻌﻠﻖ ﺧﻮﺍﻫﺪ ﺑﻮﺩ ﺩﺭ ﺍﻳﻦ ﺣﺎﻟﺖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺩﺭ ﭘﻲ ﻭ ﺗﻜﻴﻪ ﮔﺎﻫﻬﺎ ﺑﻪ ﻋﻤﻖ ﻭ ﺗﺮﺍﺯﻱ‬
‫ﻃﺮﺍﺣﻲ ﻭ ﻣﺤﺪﻭﺩ ﻣﻲ ﺷﻮﺩ ﻛﻪ ﺍﻣﻜﺎﻥ ﻋﺒﻮﺭ ﺍﺏ ﺍﺯ ﺯﻳﺮ ﻭ ﺍﻃﺮﺍﻑ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﻣﺤﺪﻭﺩ ﺑﺎﺷﺪ‪ .‬ﺍﻟﺒﺘﻪ ﺍﮔﺮ ﺍﻧﻮﺍﻉ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺑﺮ ﺍﺳﺎﺱ ﺷﻜﻞ ﻫﻨﺪﺳﻲ‬
‫ﻃﺒﻘﻪ ﺑﻨﺪﻱ ﺷﻮﺩ‪ ،‬ﺍﻧﻮﺍﻉ ﻣﺨﺘﻠﻒ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﻗﺎﺑﻞ ﻃﺒﻘﻪ ﺑﻨﺪﻱ ﺧﻮﺍﻫﺪ ﺑﻮﺩ‪.‬‬

‫‪ -٣‬ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ ﺳﺎﺧﺘﮕﺎﻩ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪: ٣‬‬


‫ﺳـﺎﺧﺘﮕﺎﻩ ﭘـﺮﻭﮊﻩ ﻛـﺎﺭﻭﻥ ‪ ٣‬ﺑـﺮ ﺭﻭﻱ ﻃﺎﻗﺪﻳﺲ ﻛﻴﻒ ﻣﻠﻚ ﻭﺍﻗﻊ ﺷﺪﻩ ﻭ ﺗﻮﺍﻟﻲ ﭼﻴﻨﻪ ﺷﻨﺎﺳﻲ ﻭ ﻟﻴﺘﻮﻟﻮﮊﻳﻜﻲ ﺳﺎﺯﻧﺪ ﻫﺎﻱ ﻣﺤﻞ ﭘﺮﻭﮊﻩ ﺍﺯ‬
‫ﻗﺪﻳﻢ ﺑﻪ ﺟﺪﻳﺪ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﻣﻲ ﺑﺎﺷﺪ ‪:‬‬

‫‪ -٣-١‬ﺳـﺎﺯﻧﺪ ﭘﺎﺑﺪﻩ ‪ :‬ﺳﺎﺯﻧﺪ ﻓﻮﻕ ﺩﺭ ﻣﺤﻞ ﺳﺎﺧﺘﮕﺎﻩ ﺗﺤﺖ ﻋﻨﻮﺍﻥ ﻭﺍﺣﺪ ‪ 3b‬ﺷﻨﺎﺧﺘﻪ ﻣﻴﺸﻮﺩ ﻭ ﺍﺯ ﻧﻈﺮ ﻟﻴﺘﻮﻟﻮﮊﻱ ﺷﺎﻣﻞ ﺗﻨﺎﻭﺑﻲ ﺍﺯ ﺳﻨﮓ‬
‫ﻫﺎﻱ ﻧﺎﺯﻙ ﻻﻳﻪ ﺗﺎ ﺿﺨﻴﻢ ﻻﻳﻪ ﺍﻫﻚ ‪ ،‬ﺷﻴﻞ ﻭ ﻣﺎﺭﻥ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪ -٣-٢‬ﺳـﺎﺯﻧﺪ ﺍﺳـﻤﺎﺭﻱ ‪ :‬ﺍﻳـﻦ ﺳـﺎﺯﻧﺪ ﻋﻤﺪﺗـﺎ" ﺷﺎﻣﻞ ﻻﻳﻪ ﻫﺎﻱ ﺍﻫﻜﻲ ﻭ ﺍﻫﻚ ﻫﺎﻱ ﻣﺎﺭﻧﻲ ﺿﺨﻴﻢ ﺗﺎ ﻧﺎﺯﻙ ﻻﻳﻪ ﻣﻲ ﺑﺎﺷﺪ ﻭ ﺩﺭ ﻣﺤﻞ‬
‫ﺳﺎﺧﺘﮕﺎﻩ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ ٣‬ﺗﺤﺖ ﻋﻨﻮﺍﻥ ﻭﺍﺣﺪ ﻫﺎﻱ ‪ 4a‬ﻭ ‪ 4b‬ﺷﻨﺎﺧﺘﻪ ﻣﻲ ﺷﻮﻧﺪ ‪ ).‬ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪( ١‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ‫‪٥٦٦‬‬

‫ﺷﺮﺡ ﻟﻴﺘﻮﻟﻮﮊﻱ‬ ‫ﺗﺸﻜﻴﻼﺕ ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ ﻋﻨﻮﺍﻥ ﻭﺍﺣﺪ‬


‫‪4b‬ﺗﻨﺎﻭﺑﻲ ﺍﺯ ﻻﻳﻪ ﻫﺎﻱ ﻧﺎﺯﻙ ﺗﺎ ﺿﺨﻴﻢ ﻣﺎﺭﻧﻲ ﻫﻤﺮﺍﻩ ﺑﺎ ﻛﻤﻲ ﺷﻴﻞ ﻭ ﻻﻳﻪ ﻫﺎﻱ ﺁﻫﻚ ﻣﺎﺭﻧﻲ ﻣﺘﻮﺳﻂ ﺗﺎ ﺿﺨﻴﻢ ﻻﻳﻪ ﻭ ﺳﻨﮓ ﺁﻫﻚ‬
‫‪4a4‬‬
‫ﺗﻨﺎﻭﺑﻲ ﺍﺯ ﻻﻳﻪ ﻫﺎﻱ ﻧﺎﺯﻙ ﺗﺎ ﺿﺨﻴﻢ ﻣﺎﺭﻧﻲ ﻫﻤﺮﺍﻩ ﺑﺎ ﻛﻤﻲ ﺷﻴﻞ ﻭ ﻻﻳﻪ ﻫﺎﻱ ﺁﻫﻚ ﻣﺎﺭﻧﻲ ﻧﺎﺯﻙ ﺗﺎ ﺿﺨﻴﻢ ﻻﻳﻪ ﻭ ﻣﺎﺭﻥ ﺑﺎ ﻛﻤﻲ ﺷﻴﻞ‬

‫ﺁﺳﻤﺎﺭﻱ‬
‫‪ a3‬ﺗﻨﺎﻭﺑﻲ ﺍﺯ ﺳﻨﮓ ﺁﻫﻚ ﺿﺨﻴﻢ ﻻﻳﻪ ﻭ ﺳﻨﮓ ﺁﻫﻚ ﻣﺎﺭﻧﻲ ﻣﺘﻮﺳﻂ ﻻﻳﻪ ﺗﺎ ﺿﺨﻴﻢ ﻻﻳﻪ‬
‫‪ 4a2‬ﺳﻨﮓ ﺁﻫﻚ ﺧﻴﻠﻲ ﺿﺨﻴﻢ ﻻﻳﻪ ﺑﻪ ﻫﻤﺮﺍﻩ ﻻﻳﻪ ﻫﺎﻱ ﻣﺎﺭﻧﻲ‬
‫‪ 4a1‬ﺗﻨﺎﻭﺑﻲ ﺍﺯ ﺳﻨﮓ ﺁﻫﻚ ﺿﺨﻴﻢ ﻻﻳﻪ ﻭ ﺳﻨﮓ ﺁﻫﻚ ﻣﺎﺭﻧﻲ ﻭ ﻣﺎﺭﻥ ﻣﺘﻮﺳﻂ ﻻﻳﻪ‬
‫‪ 3b‬ﺗﻨﺎﻭﺑﻲ ﺍﺯ ﺳﻨﮕﻬﺎﻱ ﻧﺎﺯﻙ ﻻﻳﻪ ﺗﺎ ﺿﺨﻴﻢ ﻻﻳﻪ ﺁﻫﻚ ‪ ،‬ﺷﻴﻞ ﻭ ﻣﺎﺭﻥ‬ ‫ﭘﺎﺑﺪﻩ‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ :١‬ﺗﺸﻜﻴﻼﺕ ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ ﺳﺎﺧﺘﮕﺎﻩ ﭘﺮﻭﮊﻩ ﺳﺪ ﻭ ﻧﻴﺮﻭ ﮔﺎﻩ ﻛﺎﺭﻭﻥ ‪٣‬‬

‫‪ -٤‬ﻣﻌﺮﻓﻲ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪: ٣‬‬


‫ﺷﻜﻞ ﺍﺟﺮﺍﻳﻲ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ ٣‬ﺑﻪ ﺭﻭﺵ ﻧﻴﻤﻪ ﻛﺮﺩﻥ ﻓﺎﺻﻠﻪ ﺑﻮﺩﻩ ﺑﻄﻮﺭﻳﻜﻪ ﺍﺑﺘﺪﺍ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺍﻭﻟﻴﻪ) ﺳﺮﻱ ‪ (A‬ﺑﻪ ﻓﺎﺻﻠﻪ ‪ ٨‬ﻣﺘﺮ ﺍﺯ‬
‫ﻳﻜﺪﻳﮕﺮ ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ ﻣﻴﮕﺮﺩﺩ ﻭ ﺳﭙﺲ ﺑﺘﺮﺗﻴﺐ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺛﺎﻧﻮﻳﻪ ) ﺳﺮﻱ ‪ ، ( B‬ﺛﺎﻟﺜﻴﻪ ) ﺳﺮﻱ ‪ ، (C‬ﺭﺍﺑﻌﻴﻪ ) ﺳﺮﻱ ‪ (D‬ﻭ ﺣﺘﻲ ﺧﺎﻣﺴﻴﻪ‬
‫)ﺳﺮﻱ ‪ (E‬ﺍﺟﺮﺍ ﻣﻲ ﺷﻮﻧﺪ ﻛﻪ ﺩﺭ ﻧﻬﺎﻳﺖ ﻓﺎﺻﻠﻪ ﻧﻬﺎﻳﻲ ﺑﻴﻦ ﮔﻤﺎﻧﻪ ﻫﺎ ﺑﻪ ‪ ٥٠‬ﺳﺎﻧﺘﻴﻤﺘﺮ ﻣﻴﺮﺳﺪ ) ﺷﻜﻞ ‪ (١‬ﺍﻟﺒﺘﻪ ﺍﺟﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ D‬ﻭ‬
‫‪ E‬ﺑﺼـﻮﺭﺕ ﻣـﻮﺭﺩﻱ ﺩﺭ ﺑﺨـﺶ ﻫﺎﻳـﻲ ﺍﺯ ﭘـﺮﺩﻩ ﺍﺑﺒـﻨﺪ ﻛـﻪ ﺑـﻪ ﻣﻌﻴﺎﺭ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﻳﻌﻨﻲ ﺧﻮﺭﻧﺪ ﻛﻤﺘﺮ ﺍﺯ ‪ ٥٠‬ﻛﻴﻠﻮ ﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ‬
‫ﻧﺮﺳﻴﺪﻩ ﺑﺎﺷﺪ ﻗﺎﺑﻞ ﺍﺟﺮﺍ ﺧﻮﺍﻫﺪ ﺑﻮﺩ‪.‬‬

‫‪8m‬‬
‫‪4m‬‬
‫‪2m‬‬
‫‪1m‬‬
‫‪0.5 m‬‬

‫‪A‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪C‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪B‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪C‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬

‫ﺷﻜﻞ )‪ - (١‬ﺁﺭﺍﻳﺶ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪A‬ﻭ‪B‬ﻭ‪C‬ﻭ‪D‬ﻭ‪ E‬ﭘﺮﺩﻩ ﺁﺑﺒﻨﺪ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪٣‬‬

‫ﻣﻬﻤﺘﺮﻳﻦ ﭘﺮﺩﻩ ﻫﺎﻱ ﺍﺑﺒﻨﺪ ﻃﺮﺍﺣﻲ ﺷﺪﻩ ﺩﺭ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ ٣‬ﺑﻪ ﺗﺮﺗﻴﺐ ﺍﻫﻤﻴﺖ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﻣﻲ ﺑﺎﺷﺪ ‪:‬‬
‫‪ -٤-١‬ﭘـﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺳﺪ ) ﭘﻲ ﻭ ﺗﻜﻴﻪ ﮔﺎﻩ ﻫﺎ ( ‪ :‬ﺩﺭ ﻃﺮﺍﺣﻲ ﺍﻳﻦ ﭘﺮﺩﻩ ﺳﻪ ﭘﻴﺶ ﻓﺮﺽ ﺯﻳﺮ ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﻌﻴﺎﺭﻫﺎﻱ ﺍﺻﻠﻲ ﻃﺮﺍﺣﻲ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‬
‫ﺍﺯ ﺟﻤﻠﻪ ﭼﮕﻮﻧﮕﻲ ﺍﺟﺮﺍ ﻭ ﺗﻌﺪﺍﺩ ﺭﺩﻳﻒ ﻫﺎﻱ ﭘﺮﺩﻩ ﻓﻮﻕ ﻣﻨﻈﻮﺭ ﺷﺪﻩ ﺍﺳﺖ‪.‬‬
‫‪ -‬ﻣﻌﻴﺎﺭ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﻛﻤﺘﺮ ﺍﺯ ‪ ٥٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﺩﺭ ﺗﺰﺭﻳﻖ ﭘﺬﻳﺮﻱ ﺍﺧﺮﻳﻦ ﺳﺮﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ﺩﺭ ﻫﺮ ﺭﺩﻳﻒ ﭘﺮﺩﻩ ‪.‬‬
‫‪ ٧٠-‬ﻣﺘﺮ ﺍﻭﻝ ﺍﻃﺮﺍﻑ ﺑﺪﻧﻪ ﺳﺪ ﺑﺼﻮﺭﺕ ﺳﻪ ﺭﺩﻳﻔﻪ ﺧﻮﺍﻫﺪ ﺑﻮﺩ ﻛﻪ ﺍﺣﺘﻤﺎﻻ" ﺑﺪﻟﻴﻞ ﺣﺪﺍﻛﺜﺮ ﻓﺸﺎﺭ ﻫﻴﺪﺭﻭﻟﻴﻜﻲ ﻣﺨﺰﻥ ﺩﺭ ﺍﻳﻦ ﻧﺎﺣﻴﻪ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬
‫‪ -‬ﺑﺮ ﺍﺳﺎﺱ ﻧﻈﺮ ﻃﺮﺍﺡ ﺍﮔﺮ ﺩﺭ ﺑﺨﺸﻲ ﺍﺯ ﭘﺮﺩﻩ ﺭﺩﻳﻒ ﺍﻭﻝ ﺧﻮﺭﻧﺪ ﺑﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ A‬ﺑﻴﺸﺘﺮ ﺍﺯ ‪ ٦٠٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ‬
‫ﮔﻤﺎﻧﻪ ﺑﺎﺷﺪ ‪ ،‬ﺍﻳﻦ ﺑﺨﺶ ﺍﺯ ﭘﺮﺩﻩ ﻧﻴﺰ ﺑﺼﻮﺭﺕ ﺳﻪ ﻳﺎ ﭼﻨﺪ ﺭﺩﻳﻔﻪ ﺍﺟﺮﺍ ﺧﻮﺍﻫﺪ ﺷﺪ ﻭ ﺍﮔﺮ ﺧﻮﺭﻧﺪ ﺩﺭ ﺳﺮﻱ ‪ A‬ﻛﻤﺘﺮ ﺍﺯ ‪ ٦٠٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ‬
‫ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﺑﺎﺷﺪ ﻭﻟﻲ ﺧﻮﺭﻧﺪ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ D‬ﺭﺩﻳﻒ ﺍﻭﻝ ﭘﺮﺩﻩ ﺍﺯ ‪ ٥٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﺑﻴﺸﺘﺮ ﺑﺎﺷﺪ ﺍﺑﺘﺪﺍ ﺭﺩﻳﻒ ﺩﻭﻡ‬
‫ﻭ ﺳﭙﺲ ﺍﺯ ﺭﻭﻱ ﻧﺘﺎﻳﺞ ﺭﺩﻳﻒ ﺩﻭﻡ ‪ ،‬ﺭﺩﻳﻒ ﺳﻮﻡ ﻧﻴﺰ ﻗﺎﺑﻞ ﺍﺟﺮﺍ ﺧﻮﺍﻫﺪ ﺑﻮﺩ‪.‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٦٧‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﻣﺠﻤﻮﻋـﻪ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ ﺑﺮﺍﻱ ﺍﺣﺪﺍﺙ ﺍﻳﻦ ﭘﺮﺩﻩ ﺣﺪﻭﺩ ‪ ٣٥٠٠٠٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﭘﺮﺩﻩ ﺗﺰﺭﻳﻖ ﺍﺑﺒﻨﺪ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‬
‫ﻓﻮﻕ ﺑﻪ ﺗﺮﺗﻴﺐ ﺍﺯ ﺗﺮﺍﺯﻫﺎﻱ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﻗﺎﺑﻞ ﺍﺟﺮﺍ ﺧﻮﺍﻫﺪ ﺑﻮﺩ ‪:‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٦٢١‬ﺯﻳﺮ ﭘﻲ ﺳﺪ ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ٧٩٠٠٠‬ﻣﺘﺮ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٦٥١‬ﭘﻲ ﺷﺎﻣﻞ ﺷﺎﺧﻪ ﺭﺍﺳﺖ ‪ ،‬ﺷﺎﺧﻪ ﭼﭗ ﻭ ﭘﻲ ﻣﺮﻛﺰﻱ ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ٤٨٠٠٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٧١١‬ﺩﺭ ﺷﺎﺧﻪ ﻫﺎﻱ ﺭﺍﺳﺖ ﻭ ﭼﭗ ) ﺗﻜﻴﻪ ﮔﺎﻫﻬﺎ ( ﺑﻪ ﻣﻴﺮﺍﻥ ‪ ٦٢٠٠٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ‪.‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٧٩٥‬ﺩﺭ ﺷﺎﺧﻪ ﻫﺎﻱ ﺭﺍﺳﺖ ﻭ ﭼﭗ ) ﺗﻜﻴﻪ ﮔﺎﻫﻬﺎ ( ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ١١٠٠٠٠‬ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٨٥٠‬ﺩﺭ ﺷﺎﺧﻪ ﻫﺎﻱ ﺭﺍﺳﺖ ﻭ ﭼﭗ ) ﺗﻜﻴﻪ ﮔﺎﻫﻬﺎ ( ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ٥٢٠٠٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬
‫ﻣﻘﻄﻊ ﮔﺎﻟﺮﻱ ﻫﺎﻱ ﻓﻮﻕ ﺩﺭ ﻧﻘﺸﻪ ﺷﻤﺎﺭﻩ ﻳﻚ ﺍﻣﺪﻩ ﺍﺳﺖ ‪.‬‬

‫‪ -٤-٢‬ﭘـﺮﺩﻩ ﺍﺑﺒـﻨﺪ ﺍﻃـﺮﺍﻑ ﻣﺠﻤﻮﻋﻪ ﻧﻴﺮﻭﮔﺎﻩ ‪ :‬ﻣﺠﻤـﻮﻉ ﻋﻤﻠﻴﺎﺕ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ ﺑﺮﺍﻱ ﺍﺣﺪﺍﺙ ﺍﻳﻦ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺣﺪﻭﺩ ‪ ١١٠٠٠٠‬ﻣﺘﺮ‬
‫ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺍﻳﻦ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺩﺭ ﺳﻪ ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﺍﺟﺮﺍ ﻣﻴﮕﺮﺩﺩ‪.‬‬

‫‪ -‬ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٦٧١‬ﺷﺮﻕ ﻧﻴﺮﻭﮔﺎﻩ ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ٦٠٠٠٠‬ﻣﺘﺮ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٦٦٠‬ﺷﻤﺎﻝ ﻧﻴﺮﻭﮔﺎﻩ ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ٤٠٠٠٠‬ﻣﺘﺮ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬
‫‪ -‬ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٦٦٠‬ﺟﻨﻮﺏ ﻧﻴﺮﻭﮔﺎﻩ ﺑﻪ ﻣﻴﺰﺍﻥ ‪ ١٠٠٠٠‬ﻣﺘﺮﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‪.‬‬

‫ﻻﺯﻡ ﺑﻪ ﺫﻛﺮ ﺍﺳﺖ ﻛﻪ ﺍﻳﻦ ﺳﻪ ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺩﺭ ﺟﻬﺖ ﻫﺎﻱ ﺷﺮﻕ ‪ ،‬ﺷﻤﺎﻝ ﻭ ﺟﻨﻮﺏ ﺍﻃﺮﺍﻑ ﻧﻴﺮﻭﮔﺎﻩ ﺍﺣﺪﺍﺙ ﺷﺪﻩ ﻭ ﻧﻴﺮﻭﮔﺎﻩ ﺩﺭ ﺟﻬﺖ‬
‫ﻏـﺮﺏ ﺑﻪ ﻻﻳﻪ ﻫﺎﻱ ﺍﻫﻚ ﺭﺱ ﺩﺍﺭ) ﺭﺱ ﻗﺮﻣﺰ ( ﻣﻌﺮﻭﻑ ﺑﻪ ‪ Red Bed‬ﻛﻪ ﻻﻳﻪ ﻫﺎﻱ ﻛﻢ ﺗﺮﺍﻭﺍ ﻫﺴﺘﻨﺪ ﻣﺤﺪﻭﺩ ﻣﻲ ﮔﺮﺩﺩ‪،‬ﻫﻤﭽﻨﻴﻦ ﮔﺎﻟﺮﻱ‬
‫ﻫﺎﻱ ﺷﻤﺎﻝ ﻭ ﺟﻨﻮﺏ ﻧﻴﺮﻭﮔﺎﻩ ﺍﺯ ﻳﻚ ﻃﺮﻑ ﺑﻪ ﻻﻳﻪ ﻫﺎﻱ ﻣﺎﺭﻧﻲ ﭘﺎﺑﺪﻩ ﻭ ﺍﺯ ﻃﺮﻑ ﺩﻳﮕﺮ ﺑﻪ ﻻﻳﻪ ﻫﺎﻱ ‪ Red Bed‬ﻣﺤﺪﻭﺩ ﻣﻴﮕﺮﺩﻧﺪﻭ ﮔﺎﻟﺮﻱ‬
‫ﻫـﺎﻱ ﺷـﺮﻕ ﻧـﻴﺮﻭﮔﺎﻩ ﺩﺭ ﺍﻧـﺘﻬﺎ ﺑـﻪ ﻻﻳـﻪ ﻫـﺎﻱ ﻣﺎﺭﻧﻲ ﭘﺎﺑﺪﻩ ﻭ ﺩﺭ ﺍﺑﺘﺪﺍﻱ ﮔﺎﻟﺮﻱ ﺑﻪ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺍﺣﺪﺍﺙ ﺷﺪﻩ ﺩﺭ ﮔﺎﻟﺮﻱ ﺟﻨﻮﺏ ﻧﻴﺮﻭﮔﺎﻩ ﻣﺘﺼﻞ‬
‫ﻣﻴﮕﺮﺩﺩ ‪ ،‬ﺑﺪﻳﻦ ﺗﺮﺗﻴﺐ ﺍﺑﺒﻨﺪﻱ ﺍﻃﺮﺍﻑ ﻣﺠﻤﻮﻋﻪ ﻧﻴﺮﻭﮔﺎﻩ ﺗﻜﻤﻴﻞ ﻣﻲ ﮔﺮﺩﺩ‪.‬‬

‫‪ -٤-٣‬ﭘـﺮﺩﻩ اﺑﺒـﻨﺪ ﺳﺪ ﭘﺎﺋﻴﻦ ﺩﺳﺖ ‪ :‬ﺣﺠﻢ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ ﺑﺮﺍﻱ ﺍﻳﻦ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺣﺪﻭﺩ ‪ ٣٥٠٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﺟﻬﺖ‬
‫ﺗـﺰﺭﻳﻖ ﺑـﻮﺩﻩ ﻭ ﭘـﺮﺩﻩ ﻓـﻮﻕ ﺑـﻪ ﻣﻨﻈﻮﺭ ﺟﻠﻮﮔﻴﺮﻱ ﺍﺯ ﻧﺸﺖ ﺍﺏ ﺍﺯ ﭘﺎﺋﻴﻦ ﺩﺳﺖ ﺑﻪ ﺯﻳﺮ ﺣﻮﺿﭽﻪ ﺍﺭﺍﻣﺶ ﻭ ﺟﻠﻮﮔﻴﺮﻱ ﺍﺯ ﻛﺎﻫﺶ ﺍﺛﺮ ﻧﻴﺮﻭﻱ ﺑﺎﻻ‬
‫ﺑﺮﻧﺪﻩ ) ‪ (UP LIFT‬ﺩﺭ ﺯﻳﺮ ﺳﺎﺯﻩ ﺑﺘﻨﻲ ﺣﻮﺿﭽﻪ ﺍﺭﺍﻣﺶ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫‪ -٥‬ﻧﺘﺎﻳﺞ ﺗﺰﺭﻳﻘﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺩﺭ ﭘﺮﺩﻩ ﻫﺎﻱ ﺍﺑﺒﻨﺪ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪: ٣‬‬
‫‪ - ٥-١‬ﭘﺮﺩﻩ اﺑﺒﻨﺪ ﺳﺪ ‪ :‬ﺍﻳﻦ ﻋﻤﻠﻴﺎﺕ ﺗﺎ ﻛﻨﻮﻥ ) ﺗﺎ ﺗﺎﺭﻳﺦ ﺗﻬﻴﻪ ﮔﺰﺍﺭﺵ ﻣﻬﺮ ﻣﺎﻩ ‪ ( ١٣٧٩‬ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﺍﻧﺠﺎﻡ ﭘﺬﻳﺮﻓﺘﻪ ﺍﺳﺖ‪:‬‬
‫‪ - ٥-١-١‬ﺳﺎﺣﻞ ﺭﺍﺳﺖ ‪:‬‬
‫ﺍﻟﻒ – ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ : ٨٥٠‬ﻛﻞ ﺣﻔﺎﺭﻱ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺩﺭ ﺭﺩﻳﻒ ﺍﻭﻝ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ‪ ٦٢٨١‬ﻣﺘﺮ ﻭ ﻛﻞ ﺳﻴﻤﺎﻥ ﺗﺰﺭﻳﻖ ﺷﺪﻩ ‪١٦٣٠٧٩٠‬‬
‫ﻛـﻴﻠﻮﮔﺮﻡ ﻣـﻲ ﺑﺎﺷـﺪ ﻭﻣﺘﻮﺳـﻂ ﺟـﺬﺏ ﺩﻭﻏـﺎﺏ ) ﺳﻴﻤﺎﻥ ﻣﺼﺮﻓﻲ ( ﺩﺭ ﺳﺎﺯﻧﺪﺍﺳﻤﺎﺭﻱ ﻭ ﭘﺎﺑﺪﻩ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺣﺪﻭﺩ ‪ ٢٦٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻣﻲ‬
‫ﺑﺎﺷـﺪ‪ .‬ﻻﺯﻡ ﺑـﻪ ﺗﻮﺿـﻴﺢ ﺍﺳـﺖ ﻛـﻪ ﻧﺘﺎﻳﺞ ﺑﺪﺳﺖ ﺍﻣﺪﻩ ﺩﺭ ﻣﻮﺭﺩ ﺧﻮﺭﻧﺪ ﺑﺮ ﺍﺳﺎﺱ ﺳﺮﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ﺩﺭ ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ﺷﻤﺎﺭﻩ ‪ ١،٢،٣‬ﻧﺸﺎﻥ ﺩﺍﺩﻩ‬
‫ﺷﺪﻩ ﺍﺳﺖ ﻧﺘﻴﺠﻪ ﺍﻱ ﻛﻪ ﺍﺯ ﻣﻄﺎﻟﻌﻪ ﺍﻃﻼﻋﺎﺕ ﻓﻮﻕ ﻭ ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ ﻣﺤﻞ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﺍﺯ ﭘﺮﺩﻩ ﺑﺪﺳﺖ ﻣﻲ ﺍﻳﺪ ﺑﺪﻳﻦ ﺻﻮﺭﺕ ﻗﺎﺑﻞ ﺗﻔﺴﻴﺮ‬
‫ﻣـﻲ ﺑﺎﺷﺪ ﻛﻪ ﺍﻭﻻ" ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻛﺎﻫﺶ ﻓﺸﺎﺭ ﻫﻴﺪﺭﻭﺍﺳﺘﺎﺗﻴﻚ ﺗﺮﺍﺯ ﻧﺮﻣﺎﻝ ﻣﺨﺰﻥ ) ﭘﺮﺩﻩ ﺩﺭ ﺍﻳﻦ ﻣﺤﻞ ﺍﺯ ﺗﺮﺍﺯ ‪ ٨٥٠‬ﺗﺎ ﺗﺮﺍﺯ ‪ ٧٩٠‬ﺍﺟﺮﺍ ﻣﻲ ﺷﻮﺩ ﻭ‬
‫ﺗﺮﺍﺯ ﻧﺮﻣﺎﻝ ﻣﺨﺰﻥ ‪ ٨٢٤‬ﻣﻴﺒﺎﺷﺪ ( ﻭ ﺛﺎﻧﻴﺎ" ﻗﺮﺍﺭ ﮔﺮﻓﺘﻦ ﺳﺎﺯﻧﺪ ﻣﺎﺭﻧﻲ‪-‬ﺷﻴﻠﻲ ﭘﺎﺑﺪﻩ ﺍﺯ ﺗﺮﺍﺯ ‪ ٨٢٠‬ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﺍﺯ ﭘﺮﺩﻩ ﻭ ﺛﺎﻟﺜﺎ" ﺳﻴﺮ ﻧﺰﻭﻟﻲ ﺧﻮﺭﻧﺪ‬
‫ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺭﺩﻳﻒ ﺍﻭﻝ ‪ ،‬ﺍﻣﻜﺎﻥ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﭘﺮﺩﻩ ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﺑﺎ ﺭﺩﻳﻒ ﺍﻭﻝ ﺍﺟﺮﺍ ﺷﺪﻩ ﻓﻌﻠﻲ ﻗﺎﺑﻞ ﺑﺮﺭﺳﻲ ﺑﻮﺩﻩ ﻭ ﻧﻴﺎﺯ ﺑﻪ ﺭﺩﻳﻒ ﻫﺎﻱ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ‫‪٥٦٨‬‬

‫ﺑﻌـﺪﻱ ﺭﺍ ﻣﻨﺘﻔﻲ ﻣﻲ ﻧﻤﺎﻳﺪ ) ﻻﺯﻡ ﺑﻪ ﺗﻮﺿﻴﺢ ﻣﻲ ﺑﺎﺷﺪ ﻣﻘﺎﺩﻳﺮﻱ ﺍﺯ ﺳﻴﻤﺎﻥ ﺗﺰﺭﻳﻘﻲ ﺍﺯ ﮔﺎﻟﺮﻱ ﻫﺎﻱ ﺗﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺗﺮ ﺑﺼﻮﺭﺕ ﻧﺸﺖ ﺍﺯ ﺩﺳﺖ ﺭﻓﺘﻪ‬
‫ﻛﻪ ﺩﺭ ﺍﻣﺎﺭ ﻣﺼﺮﻓﻲ ﺧﻮﺭﻧﺪ ﮔﻤﺎﻧﻪ ﻫﺎ ﻣﺤﺎﺳﺒﻪ ﮔﺮﺩﻳﺪﻩ ﺍﺳﺖ (‬

‫ﺷﻜﻞ ﺷﻤﺎﺭﻩ ‪۱‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٦٩‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﺸﺮﺡ ﺯﻳﺮ ﺑﻮﺩﻩ ﺍﺳﺖ ‪:‬‬


‫‪ -‬ﺭﻭﺵ ﺗـﺰﺭﻳﻖ‪ ،‬ﺑﺼـﻮﺭﺕ ﻣﺘﻌﺎﺭﻑ ﺑﺎ ﻧﺼﺐ ﭘﻜﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ) ﺑﺠﺰ ﺩﺭ ﻣﻮﺍﺭﺩ ﮔﻤﺸﺪﮔﻲ ﺍﺏ ﺩﺭ ﺩﺍﺧﻞ ﮔﻤﺎﻧﻪ ﻛﻪ ﺗﺰﺭﻳﻖ ﺑﻪ ﺭﻭﺵ ﺍﺯ ﺑﺎﻻ‬
‫ﺑﻪ ﭘﺎﺋﻴﻦ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ (‪.‬‬
‫‪ -‬ﻓﺸﺎﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﺩﺭ ﺗﻤﺎﻣﻲ ﺳﺮﻱ ﻫﺎ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎ ﺣﺪﺍﻛﺜﺮ ‪ ٢٠‬ﺑﺎﺭ ﻭ ﺑﺮ ﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪٢‬‬
‫‪ -‬ﺣﺪﺍﻛﺜﺮ ﻋﻤﻖ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ٦٠‬ﻣﺘﺮ‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ١١‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ‬
‫‪ -‬ﺍﺯﻳﻤﻮﺕ ﺩﺭ ﺑﺨﺶ ﺍﺑﺘﺪﺍﺋﻲ ﮔﺎﻟﺮﻱ ‪ ) N 120‬ﻓﺎﺻﻠﻪ ﻧﻘﻄﻪ ‪ A‬ﺗﺎ ‪ ( B‬ﻭ ﺩﺭ ﺑﺨﺶ ﺍﻧﺘﻬﺎﺋﻲ ﮔﺎﻟﺮﻱ ‪ ) N 135‬ﻓﺎﺻﻠﻪ ﻧﻘﻄﻪ ‪ B‬ﺗﺎ ‪(C‬‬
‫‪ -‬ﻣﺼﺎﻟﺢ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﻭﻏﺎﺏ ﺳﻴﻤﺎﻥ ﺑﺎ ﺍﺏ ﺑﻪ ﻧﺴﺒﺖ ﺍﺏ ‪ :‬ﺳﻴﻤﺎﻥ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ ١/٥ :١ ، ١:١، ١:١/٥ ، ١:٢‬ﻭ ‪٢:١‬‬

‫‪SERIES‬‬ ‫‪GROUTING‬‬ ‫‪SERIES‬‬ ‫‪DRILLING‬‬ ‫‪SERIES‬‬ ‫‪KG /M‬‬


‫‪A‬‬ ‫‪864710‬‬ ‫‪A‬‬ ‫‪1296‬‬ ‫‪A‬‬ ‫‪667 . 214506‬‬
‫‪B‬‬ ‫‪240840‬‬ ‫‪B‬‬ ‫‪940‬‬ ‫‪B‬‬ ‫‪256 . 212766‬‬
‫‪C‬‬ ‫‪208425‬‬ ‫‪C‬‬ ‫‪1755‬‬ ‫‪C‬‬ ‫‪118 . 760684‬‬
‫‪D‬‬ ‫‪248705‬‬ ‫‪D‬‬ ‫‪1362‬‬ ‫‪D‬‬ ‫‪182 . 60279‬‬
‫‪E‬‬ ‫‪68110‬‬ ‫‪E‬‬ ‫‪928‬‬ ‫‪E‬‬ ‫‪73 . 3943966‬‬
‫‪GROUTING‬‬ ‫‪DRILLING‬‬ ‫‪KG /M‬‬

‫‪1000000‬‬ ‫‪2000‬‬ ‫‪800‬‬

‫‪900000‬‬ ‫‪1800‬‬
‫‪700‬‬

‫‪800000‬‬ ‫‪1600‬‬

‫‪600‬‬

‫‪700000‬‬ ‫‪1400‬‬

‫‪500‬‬
‫‪600000‬‬ ‫‪1200‬‬

‫‪500000‬‬ ‫‪GROUTING‬‬ ‫‪1000‬‬ ‫‪DRILLING‬‬ ‫‪400‬‬ ‫‪KG /M‬‬

‫‪400000‬‬ ‫‪800‬‬
‫‪300‬‬

‫‪300000‬‬ ‫‪600‬‬

‫‪200‬‬

‫‪200000‬‬ ‫‪400‬‬

‫‪100‬‬
‫‪100000‬‬ ‫‪200‬‬

‫‪0‬‬ ‫‪0‬‬ ‫‪0‬‬


‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪D‬‬ ‫‪E‬‬

‫ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ‪ ۲ ،۱‬ﻭ ‪ - ۳‬ﻧﺘﺎﻳﺞ ﻣﺮﺑﻮﻁ ﺑﻪ ﺗﺰﺭﻳﻘﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺩﺭ ﮔﺎﻟﺮﻱ ‪ ۸۵۰‬ﺭﺍﺳﺖ‬

‫‪DEPTH‬‬ ‫‪SE . A‬‬ ‫‪SE . B‬‬ ‫‪SE . C&D&E‬‬


‫‪0 -- 5‬‬ ‫‪1 .5‬‬ ‫‪1.5‬‬ ‫‪1.5‬‬
‫‪5 -- 10‬‬ ‫‪2 .5‬‬ ‫‪3‬‬ ‫‪3.5‬‬
‫‪10 -- 15‬‬ ‫‪4‬‬ ‫‪4.5‬‬ ‫‪5‬‬
‫‪15 -- 20‬‬ ‫‪5‬‬ ‫‪6.5‬‬ ‫‪7‬‬
‫‪20 -- 25‬‬ ‫‪6 .5‬‬ ‫‪8‬‬ ‫‪9‬‬
‫‪25 -- 30‬‬ ‫‪8‬‬ ‫‪10‬‬ ‫‪11 . 5‬‬
‫‪30 -- 35‬‬ ‫‪9‬‬ ‫‪12‬‬ ‫‪14‬‬
‫‪35 -- 40‬‬ ‫‪10 . 5‬‬ ‫‪14‬‬ ‫‪17‬‬
‫‪40 -- 45‬‬ ‫‪12‬‬ ‫‪16 . 5‬‬ ‫‪19 . 5‬‬
‫‪45 -- 50‬‬ ‫‪13‬‬ ‫‪18 . 5‬‬ ‫‪22 . 5‬‬
‫‪> 50‬‬ ‫‪15‬‬ ‫‪20‬‬ ‫‪25‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ۲‬ﻓﺸﺎﺭﻫﺎﻱ ﺗﺰﺭﻳﻖ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﺭ ﮔﺎﻟﺮﻱ ‪۸۵۰‬ﺭﺍﺳﺖ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ‫‪٥٧٠‬‬

‫ﺏ ‪ -‬ﮔﺎﻟـﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ : ٧٩٥‬ﻛﻞ ﺣﻔﺎﺭﻱ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ‪ ٤٨٣٦‬ﻣﺘﺮ ﻭ ﺳﻴﻤﺎﻥ ﺗﺰﺭﻳﻖ ﺷﺪﻩ ‪ ٥٠١٨٣٩‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﺭﺩﻳﻒ ﺍﻭﻝ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‬
‫ﺍﻳـﻦ ﮔﺎﻟـﺮﻱ ﻣـﻲ ﺑﺎﺷـﺪ ﻛﻪ ﻋﻤﻠﻴﺎﺕ ﻓﻮﻕ ﺩﺭ ﺣﺪﻭﺩ ‪ %٩٥‬ﻣﻘﺎﻃﻊ ﺗﺰﺭﻳﻖ ﺷﺪﻩ ﺩﺭ ﺳﺎﺯﻧﺪ ﻣﺎﺭﻧﻲ‪ -‬ﺷﻴﻠﻲ ﭘﺎﺑﺪﻩ ﺍﺟﺮﺍ ﮔﺮﺩﻳﺪﻩ ﻛﻪ ﺩﺍﺭﺍﻱ ﻣﺘﻮﺳﻂ‬
‫ﺟﺬﺏ ﺩﻭﻏﺎﺏ ‪ ١٠٤‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺑﺎﺗﻮﺟﻪ ﺑﻪ ﻧﺘﺎﻳﺞ ﺑﺪﺳﺖ ﺍﻣﺪﻩ ﺩﺭ ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ﺷﻤﺎﺭﻩ ‪ ٥ ،٤‬ﻭ‪ ٦‬ﻭ ﻣﺘﻮﺳﻂ ﺟﺬﺏ‬
‫ﺩﻭﻏـﺎﺏ ) ﺳـﻴﻤﺎﻥ ﻣﺼـﺮﻓﻲ ﺑﺮ ﺍﺳﺎﺱ ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻃﻮﻝ ﻣﺘﺮ ﮔﻤﺎﻧﻪ ( ﺩﺭ ﺍﺧﺮﻳﻦ ﺳﺮﻱ ) ﺳﺮﻱ ‪ ( C‬ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺍﺟﺮﺍ ﺷﺪﻩ ‪ ،‬ﭘﺮﺩﻩ ﺍﻭﻝ ﺩﺭ ﺍﻳﻦ‬
‫ﻣﺤـﻞ ﺑـﻪ ﻋـﺪﺩ ﻧﺰﺩﻳﻚ ﺑﻪ ﻋﺪﺩ ﻣﻌﻴﺎﺭ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪ ﻣﻲ ﺑﺎﺷﺪ ) ‪ ٥٧‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ( ﺑﻨﻈﺮ ﻣﻲ ﺭﺳﺪ ﺑﺎ ﺍﺟﺮﺍﻱ ﺗﻌﺪﺍﺩﻱ ﮔﻤﺎﻧﻪ ﺑﻪ‬
‫ﻓﻮﺍﺻﻞ ﺣﺪﺍﻗﻞ ‪ ٦‬ﻣﺘﺮ ﺑﻌﻨﻮﺍﻥ ﭘﺮﺩﻩ ﺩﻭﻡ ﺍﺯ ﺍﺟﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺑﻴﺸﺘﺮ ﺩﺭ ﺍﻳﻦ ﻣﺤﻞ ﺑﻲ ﻧﻴﺎﺯ ﺧﻮﺍﻫﻴﻢ ﺑﻮﺩ‪.‬‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﺸﺮﺡ ﺯﻳﺮ ﺑﻮﺩﻩ ﺍﺳﺖ ‪:‬‬


‫‪ -‬ﺭﻭﺵ ﺗﺰﺭﻳﻖ‪ ،‬ﺑﺼﻮﺭﺕ ﻣﺘﻌﺎﺭﻑ ﺑﺎ ﻧﺼﺐ ﭘﻜﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ) ﺑﺠﺰ ﺩﺭ ﻣﻮﺍﺭﺩ ﮔﻤﺸﺪﮔﻲ ﺍﺏ ﺩﺭ ﺩﺍﺧﻞ ﮔﻤﺎﻧﻪ ﻛﻪ ﺗﺰﺭﻳﻖ ﺑﻪ ﺭﻭﺵ ﺍﺯ ﺑﺎﻻ ﺑﻪ‬
‫ﭘﺎﺋﻴﻦ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ (‪.‬‬
‫‪ -‬ﻓﺸﺎﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﺩﺭ ﺗﻤﺎﻣﻲ ﺳﺮﻱ ﻫﺎ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎ ﺣﺪﺍﻛﺜﺮ ‪ ٣٠‬ﺑﺎﺭ ﻭ ﺑﺮ ﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪٣‬‬
‫‪ -‬ﺣﺪﺍﻛﺜﺮ ﻋﻤﻖ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ١١٥‬ﻣﺘﺮ‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ٣٠‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ‬
‫‪ -‬ﺍﺯﻳﻤﻮﺕ ﺩﺭ ﺑﺨﺶ ﺍﺑﺘﺪﺍﺋﻲ ﮔﺎﻟﺮﻱ ‪ ) N 120‬ﻓﺎﺻﻠﻪ ﻧﻘﻄﻪ ‪ A‬ﺗﺎ ‪ ( B‬ﻭ ﺩﺭ ﺑﺨﺶ ﺍﻧﺘﻬﺎﺋﻲ ﮔﺎﻟﺮﻱ ‪ ) N 135‬ﻓﺎﺻﻠﻪ ﻧﻘﻄﻪ ‪ B‬ﺗﺎ ‪( C‬‬
‫‪ -‬ﻣﺼﺎﻟﺢ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﻭﻏﺎﺏ ﺳﻴﻤﺎﻥ ﺑﺎ ﺍﺏ ﺑﻪ ﻧﺴﺒﺖ ﺍﺏ ‪ :‬ﺳﻴﻤﺎﻥ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ ١/٥ :١ ، ١:١ ، ١:١/٥ ، ١:٢‬ﻭ‪٢:١‬‬

‫‪SERIES‬‬ ‫‪DRILING‬‬ ‫‪SERIES‬‬ ‫‪GROUITNG‬‬ ‫‪SERIES‬‬ ‫‪KG/M‬‬


‫‪A‬‬ ‫‪2200‬‬ ‫‪A‬‬ ‫‪441767‬‬ ‫‪A‬‬ ‫‪200.803‬‬
‫‪B‬‬ ‫‪1789‬‬ ‫‪B‬‬ ‫‪191054‬‬ ‫‪B‬‬ ‫‪106.79‬‬
‫‪C‬‬ ‫‪2225‬‬ ‫‪C‬‬ ‫‪127709‬‬ ‫‪C‬‬ ‫‪57.39‬‬
‫‪DRILING‬‬ ‫‪GROUITNG‬‬ ‫‪KG/M‬‬

‫‪500000‬‬ ‫‪250‬‬
‫‪2500‬‬

‫‪450000‬‬

‫‪2000‬‬ ‫‪400000‬‬ ‫‪200‬‬

‫‪350000‬‬

‫‪1500‬‬ ‫‪300000‬‬
‫‪150‬‬

‫‪DRILING‬‬ ‫‪KG/M‬‬
‫‪250000‬‬ ‫‪GROUITNG‬‬

‫‪1000‬‬ ‫‪100‬‬
‫‪200000‬‬

‫‪150000‬‬

‫‪500‬‬ ‫‪50‬‬
‫‪100000‬‬

‫‪50000‬‬

‫‪0‬‬ ‫‪0‬‬
‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪0‬‬ ‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬
‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬

‫ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ﺷﻤﺎﺭﻩ ‪ ٥ ، ٤‬ﻭ ‪ - ٦‬ﻧﺘﺎﻳﺞ ﻣﺮﺑﻮﻁ ﺑﻪ ﺗﺰﺭﻳﻘﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺩﺭ ﮔﺎﻟﺮﻱ ‪ ٧٩٥‬ﺭﺍﺳﺖ‬

‫‪ -٥-١-۲‬ﺳﺎﺣﻞ ﭼﭗ ‪:‬‬
‫ﺍﻟـﻒ ‪ -‬ﮔﺎﻟـﺮﻱ ﺗـﺰﺭﻳﻖ ﺗـﺮﺍﺯ ‪ : ٨٥٠‬ﻣﺠﻤـﻮﻉ ﻋﻤﻠـﻴﺎﺕ ﺍﻧﺠـﺎﻡ ﺷﺪﻩ ﺩﺭ ﺭﺩﻳﻒ ﺍﻭﻝ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ‪ ١١٥٦٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﻭ‬
‫‪ ٥٧٥٠٥٠٠‬ﻛـﻴﻠﻮﮔﺮﻡ ﺳـﻴﻤﺎﻥ ﺗﺰﺭﻳﻘـﻲ ﺩﺭ ﺳﺎﺯﻧﺪ ﺍﻫﻚ ﺍﺳﻤﺎﺭﻱ ) ‪ ( 4a2-4a3-4a4‬ﻛﻪ ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ﺍﻥ ‪ ٤٩٨‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٧١‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﻃـﻮﻝ ﮔﻤﺎﻧـﻪ ﻣﻲ ﺑﺎﺷﺪ‪ .‬ﺩﺭ ﺭﺩﻳﻒ ﺩﻭﻡ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ‪ ٧٠٨٠‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﻭ ‪ ٨٦٢٦٩٨‬ﻛﻴﻠﻮﮔﺮﻡ ﺳﻴﻤﺎﻥ ﺗﺰﺭﻳﻖ ﺷﺪﻩ ﺍﺳﺖ ﻛﻪ ﻣﺘﻮﺳﻂ‬
‫ﺟـﺬﺏ ﺩﻭﻏـﺎﺏ ﺩﺭ ﺍﻳـﻦ ﭘﺮﺩﻩ ‪ ١٢٢‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻭ ﺩﺭ ﺭﺩﻳﻒ ﺳﻮﻡ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ‪ ٤٩٤٢‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﻭ ‪ ٨٩٠٥٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺳﻴﻤﺎﻥ‬
‫ﺗﺰﺭﻳﻖ ﺷﺪﻩ ﺍﺳﺖ ﻛﻪ ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ‪ ١٨‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬
‫ﺍﮔـﺮ ﻣﻌـﻴﺎﺭ ﻫـﺎﻱ ﺳﻪ ﮔﺎﻧﻪ ﻃﺮﺍﺣﻲ ﺷﺪﻩ ﭘﺮﺩﻩ ) ﺍﺷﺎﺭﻩ ﺷﺪﻩ ﺩﺭ ﺑﺨﺶ ﻗﺒﻞ ( ﺭﺍ ﺑﻌﻨﻮﺍﻥ ﻣﻌﻴﺎﺭﻫﺎﻱ ﺍﺻﻠﻲ ﺳﻪ ﺭﺩﻳﻔﻪ ﺑﻮﺩﻥ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺩﺭ ﺍﻳﻦ‬
‫ﺑﺨﺶ ﺍﺯ ﭘﺮﺩﻩ ﺩﺭ ﻧﻈﺮ ﺑﮕﻴﺮﻳﻢ ﺍﻣﺎﺭ ﻭ ﺍﻃﻼﻋﺎﺕ ﺣﺎﺻﻠﻪ ﺍﺯ ﺗﺰﺭﻳﻖ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺭﺩﻳﻒ ﺩﻭﻡ ﻭ ﺳﻮﻡ ﭘﺮﺩﻩ ﺩﺭ ﮔﺎﻟﺮﻱ ‪ ٨٥٠‬ﭼﭗ ﻟﺰﻭﻡ ﺗﺠﺪﻳﺪ ﻧﻈﺮ‬
‫ﺩﺭ ﻃﺮﺍﺣﻲ ﺳﻪ ﺭﺩﻳﻔﻪ ﺑﻮﺩﻥ ﭘﺮﺩﻩ ﺣﺪﺍﻗﻞ ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﺍﺯ ﭘﺮﺩﻩ ﺭﺍ ﺑﺨﻮﺑﻲ ﻧﺸﺎﻥ ﻣﻴﺪﻫﺪ‪.‬‬
‫ﺑـﺮ ﺍﺳﺎﺱ ﺍﻣﺎﺭ ﻭ ﺍﻃﻼﻋﺎﺕ ﻣﻮﺟﻮﺩ ﺩﺭ ﺟﺪﺍﻭﻝ ‪ ٥ ، ٤‬ﻭ ‪ ٦‬ﻭ ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ‪ ٧‬ﻭ ‪ ٨‬ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ A‬ﺭﺩﻳﻒ ﺩﻭﻡ ﭘﺮﺩﻩ‬
‫ﺩﺭ ﺍﻳـﻦ ﮔﺎﻟـﺮﻱ ﺣـﺪﻭﺩ ‪ ٣٢٤‬ﻛـﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣـﺘﺮ ﻃـﻮﻝ ﮔﻤﺎﻧﻪ ‪ ،‬ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ B‬ﺣﺪﻭﺩ ‪ ١٣٥‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ‪ ،‬ﮔﻤﺎﻧﻪ ﻫﺎﻱ‬
‫ﺳﺮﻱ ‪ C‬ﺣﺪﻭﺩ ‪ ١٠٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ D‬ﺣﺪﻭﺩ ‪ ٨٥‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﺑﻮﺩﻩ ﺍﺳﺖ ﻛﻪ ﺍﻳﻦ ﻣﻴﺰﺍﻥ‬
‫ﺧﻮﺭﻧـﺪ ﺩﺭ ﮔﻤﺎﻧـﻪ ﻫـﺎﻱ ﺭﺩﻳﻒ ﺳﻮﻡ ﭘﺮﺩﻩ ﺩﺭ ﺳﺮﻱ ‪ A‬ﺣﺪﻭﺩ ‪ ١٤‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ‪ ،‬ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ B‬ﺣﺪﻭﺩ ‪ ١٧‬ﻛﻴﻠﻮﮔﺮﻡ‬
‫ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻭ ﺳﺮ‪ C‬ﺣﺪﻭﺩ ‪ ٢٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﺑﻮﺩﻩ ﺍﺳﺖ ﻧﺘﻴﺠﻪ ﺍﻳﻨﻜﻪ ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﭘﺮﺩﻩ ﺳﻮﻡ ﺣﺪﻭﺩ‬
‫ﻳﻚ ﺳﻮﻡ ﻣﻌﻴﺎﺭ ﭘﻴﺸﻨﻬﺎﺩ ﺷﺪﻩ ﺑﺮﺍﻱ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ) ‪ ٥٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ( ﺑﻮﺩﻩ ﺍﺳﺖ ﻭ ﺍﺯ ﻃﺮﻑ ﺩﻳﮕﺮ ﺧﻮﺭﻧﺪ ﻫﺎﻱ ﺍﺭﺍﺋﻪ ﺷﺪﻩ‬
‫ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺭﺩﻳﻒ ﺳﻮﻡ ﭘﺮﺩﻩ ﻋﻤﺪﺗﺎ" ﻏﻴﺮ ﻭﺍﻗﻌﻲ ﻭ‬

‫‪0--5‬‬ ‫‪1‬‬ ‫‪2‬‬ ‫‪1‬‬ ‫‪2‬‬ ‫‪0--5‬‬ ‫‪1‬‬ ‫‪2‬‬


‫‪5--10‬‬ ‫‪3‬‬ ‫‪5‬‬ ‫‪3‬‬ ‫‪6‬‬ ‫‪5--10‬‬ ‫‪3‬‬ ‫‪6‬‬
‫‪10--15‬‬ ‫‪4‬‬ ‫‪7‬‬ ‫‪4‬‬ ‫‪10 10--15‬‬ ‫‪4‬‬ ‫‪10‬‬
‫‪15--20‬‬ ‫‪5‬‬ ‫‪8‬‬ ‫‪5‬‬ ‫‪14 15--20‬‬ ‫‪5‬‬ ‫‪14‬‬
‫‪20--25‬‬ ‫‪6‬‬ ‫‪10‬‬ ‫‪6‬‬ ‫‪16 20--25‬‬ ‫‪6‬‬ ‫‪16‬‬
‫‪25--30‬‬ ‫‪7‬‬ ‫‪12‬‬ ‫‪8‬‬ ‫‪18 25--30‬‬ ‫‪8‬‬ ‫‪18‬‬
‫‪30--35‬‬ ‫‪8‬‬ ‫‪13‬‬ ‫‪10‬‬ ‫‪20 30--35‬‬ ‫‪10‬‬ ‫‪20‬‬
‫‪35--40‬‬ ‫‪9‬‬ ‫‪14‬‬ ‫‪10‬‬ ‫‪22 35--40‬‬ ‫‪10‬‬ ‫‪22‬‬
‫‪40--45‬‬ ‫‪10‬‬ ‫‪16‬‬ ‫‪10‬‬ ‫‪24 40--45‬‬ ‫‪10‬‬ ‫‪24‬‬
‫‪45--50‬‬ ‫‪10‬‬ ‫‪18‬‬ ‫‪10‬‬ ‫‪25 45--50‬‬ ‫‪10‬‬ ‫‪25‬‬
‫‪50--55‬‬ ‫‪10‬‬ ‫‪20‬‬ ‫‪12‬‬ ‫‪30 50--55‬‬ ‫‪12‬‬ ‫‪30‬‬
‫‪55--60‬‬ ‫‪12‬‬ ‫‪22‬‬ ‫‪12‬‬ ‫‪30 55--60‬‬ ‫‪12‬‬ ‫‪30‬‬
‫‪60--65‬‬ ‫‪12‬‬ ‫‪24‬‬ ‫‪12‬‬ ‫‪30 60--65‬‬ ‫‪12‬‬ ‫‪30‬‬
‫‪65--70‬‬ ‫‪12‬‬ ‫‪25‬‬ ‫‪12‬‬ ‫‪30 65--70‬‬ ‫‪12‬‬ ‫‪30‬‬
‫‪70--75‬‬ ‫‪12‬‬ ‫‪25‬‬ ‫‪12‬‬ ‫‪30 70--75‬‬ ‫‪12‬‬ ‫‪30‬‬
‫‪75--80‬‬ ‫‪12‬‬ ‫‪25‬‬ ‫‪12‬‬ ‫‪30 75--80‬‬ ‫‪12‬‬ ‫‪30‬‬
‫‪80--85‬‬ ‫‪15‬‬ ‫‪25‬‬ ‫‪15‬‬ ‫‪30 80--85‬‬ ‫‪15‬‬ ‫‪30‬‬
‫‪85--90‬‬ ‫‪15‬‬ ‫‪25‬‬ ‫‪15‬‬ ‫‪30 85--90‬‬ ‫‪15‬‬ ‫‪30‬‬
‫‪90--95‬‬ ‫‪15‬‬ ‫‪25‬‬ ‫‪15‬‬ ‫‪30 90--95‬‬ ‫‪15‬‬ ‫‪30‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ : ۳‬ﻓﺸﺎﺭﻫﺎﻱ ﺗﺴﺖ ﻭ ﺗﺰﺭﻳﻖ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺁﺑﺒﻨﺪ ﻃﺮﺡ ﻛﺎﺭﻭﻥ ‪۳‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ‫‪٥٧٢‬‬

‫ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ‬ ‫ﺍﻧﺠﺎﻡ ﺷﺪﻩ‬


‫ﺳﺮﻱ‪A‬‬ ‫‪250‬‬ ‫‪14.33‬‬
‫ﺳﺮﻱ‪B‬‬ ‫‪100‬‬ ‫‪17.1‬‬
‫ﺳﺮﻱ‪C‬‬ ‫‪50‬‬ ‫‪20.27‬‬

‫‪300‬‬

‫‪250‬‬

‫‪200‬‬
‫ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ‬
‫‪150‬‬
‫اﻧﺠﺎم ﺷﺪﻩ‬
‫‪100‬‬

‫‪50‬‬

‫‪0‬‬
‫ﺳﺮي‪A‬‬ ‫ﺳﺮي‪B‬‬ ‫ﺳﺮي‪C‬‬

‫ﻧﻤﻮﺩﺍﺭ ﺷﻤﺎﺭﻩ ‪ - ۸‬ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﺳﻴﻤﺎﻥ ﺩﺭ ﻻﻳﻦ ‪ ۳‬ﮔﺎﻟﺮﻱ ‪ ۸۵۰‬ﭼﭗ‬


‫ﺑﺼـﻮﺭﺕ ﺳـﻴﻤﺎﻥ ﻫـﺪﺭ ﺭﻓـﺘﻪ ﺩﺭ ﻣﺴـﻴﺮﻫﺎﻱ ﺗـﺰﺭﻳﻖ ﺑﻮﺩﻩ ﺍﺳﺖ ‪ .‬ﺑﻨﺎﺑﺮﺍﻳﻦ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻧﺘﺎﻳﺞ ﻭﺍﻃﻼﻋﺎﺕ ﺍﺷﺎﺭﻩ ﺷﺪﻩ ﻭ ﻫﻤﭽﻨﻴﻦ ﺗﺮﺍﺯ ﺍﺏ ﺩﺭ ﺍﻳﻦ‬
‫ﺑﺨـﺶ ﺍﺯ ﭘﺮﺩﻩ ﺣﺪﺍﻛﺜﺮ ﺑﺎ ﺍﺟﺮﺍﻱ ﺗﻌﺪﺍﺩﻱ ﮔﻤﺎﻧﻪ ﺍﻭﻟﻴﻪ ﺑﻪ ﻓﻮﺍﺻﻞ ﺣﺪﺍﻗﻞ ‪ ١٠‬ﻣﺘﺮ ﺩﺭ ﭘﺮﺩﻩ ﺳﻮﻡ ﻫﻢ ﺿﺮﻳﺐ ﺍﻃﻤﻴﻨﺎﻥ ﺍﺑﺒﻨﺪﻱ ﺑﺎﻻﺗﺮ ﻣﻲ ﺭﻓﺖ ﻭ‬
‫ﻫﻢ ﺍﻳﻨﻜﻪ ﺑﺼﻮﺭﺕ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﻛﻨﺘﺮﻝ ﺩﺭ ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪﻩ ﻭ ﻟﺰﻭﻡ ﺍﺟﺮﺍﻱ ﺳﺎﻳﺮ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺍﻳﻦ ﺭﺩﻳﻒ ﺍﺯ ﭘﺮﺩﻩ ﻣﻨﺘﻔﻲ ﻣﻲ ﺷﺪ‪.‬‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﺸﺮﺡ ﺯﻳﺮ ﺑﻮﺩﻩ ﺍﺳﺖ ‪:‬‬


‫‪ -‬ﺭﻭﺵ ﺗـﺰﺭﻳﻖ‪ ،‬ﺑﺼـﻮﺭﺕ ﻣﺘﻌﺎﺭﻑ ﺑﺎ ﻧﺼﺐ ﭘﻜﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ) ﺑﺠﺰ ﺩﺭ ﻣﻮﺍﺭﺩ ﮔﻤﺸﺪﮔﻲ ﺍﺏ ﺩﺭ ﺩﺍﺧﻞ ﮔﻤﺎﻧﻪ ﻛﻪ ﺗﺰﺭﻳﻖ ﺑﻪ ﺭﻭﺵ ﺍﺯ ﺑﺎﻻ‬
‫ﺑﻪ ﭘﺎﺋﻴﻦ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ (‪.‬‬
‫‪ -‬ﻓﺸـﺎﺭ ﻣـﻮﺭﺩ ﺍﺳـﺘﻔﺎﺩﻩ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﺩﺭ ﺗﻤﺎﻣﻲ ﺳﺮﻱ ﻫﺎ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﭘﺮﺩﻩ ﺍﻭﻝ ﻭ ﺩﻭﻡ ﺣﺪﺍﻛﺜﺮ ‪ ٢٠‬ﺑﺎﺭ ﻭ ﺩﺭ ﭘﺮﺩﻩ ﺳﻮﻡ ﺣﺪﺍﻛﺜﺮ ‪ ٣٠‬ﺑﺎﺭ‪ ،‬ﺑﺮ‬
‫ﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ ٣‬ﻣﻲ ﺑﺎﺷﺪ‪.‬‬
‫‪ -‬ﺣﺪﺍﻛﺜﺮ ﻋﻤﻖ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ٨٠‬ﻣﺘﺮ‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎﺩﺭ ﭘﺮﺩﻩ ﺍﻭﻝ ‪ ٩‬ﺩﺭﺟﻪ ‪ ،‬ﺩﺭ ﭘﺮﺩﻩ ﺩﻭﻡ ‪ ٤‬ﺩﺭﺟﻪ ﻭ ﺩﺭ ﭘﺮﺩﻩ ﺳﻮﻡ ‪ ٦‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ‬
‫‪ -‬ﺍﺯﻳﻤﻮﺕ ﺩﺭﭘﺮﺩﻩ ﺍﻭﻝ ‪ ، N45‬ﺩﺭ ﭘﺮﺩﻩ ﺩﻭﻡ‪ N180‬ﻭ ﺩﺭﭘﺮﺩﻩ ﺳﻮﻡ ‪N90‬‬

‫‪ -‬ﻣﺼﺎﻟﺢ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﻭﻏﺎﺏ ﺳﻴﻤﺎﻥ ﺑﺎ ﺍﺏ ﺑﻪ ﻧﺴﺒﺖ ﺍﺏ ‪ :‬ﺳﻴﻤﺎﻥ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ ١/٥ :١ ، ١:١ ، ١:١/٥ ، ١:٢‬ﻭ‪٢:١‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٧٣‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ‬ ‫ﺍﻧﺠﺎﻡ ﺷﺪﻩ‬


‫ﺳﺮﻱ‪A‬‬ ‫‪500‬‬ ‫‪273.12‬‬
‫ﺳﺮﻱ‪B‬‬ ‫‪250‬‬ ‫‪135.21‬‬
‫ﺳﺮﻱ‪C‬‬ ‫‪100‬‬ ‫‪100.4‬‬
‫ﺳﺮﻱ‪D‬‬ ‫‪50‬‬ ‫‪84.82‬‬

‫‪600‬‬

‫‪500‬‬

‫‪400‬‬

‫ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ‬


‫‪300‬‬
‫اﻧﺠﺎم ﺷﺪﻩ‬

‫‪200‬‬

‫‪100‬‬

‫‪0‬‬
‫ﺳﺮي‪A‬‬ ‫ﺳﺮي‪B‬‬ ‫ﺳﺮي‪C‬‬ ‫ﺳﺮي‪D‬‬

‫ﻧﻤﻮﺩﺍﺭ ﺷﻤﺎﺭﻩ ‪ - ٧‬ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﺳﻴﻤﺎﻥ ﺩﺭ ﺭﺩﻳﻒ ﺩﻭﻡ ﮔﺎﻟﺮﻱ ‪ ٨٥٠‬ﭼﭗ‬

‫‪AVERAGE LINE ONE‬‬ ‫) ‪= 121 . 85 ( KG / M‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ٤‬ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ ﻻﻳﻦ ﺩﻭﻡ ﮔﺎﻟﺮﻱ ‪٨٥٠‬ﭼﭗ‬

‫‪SERIIES‬‬ ‫‪DRILLING‬‬ ‫‪GROUTING‬‬ ‫‪AVERAGE‬‬


‫‪A‬‬ ‫‪1202‬‬ ‫‪17236‬‬ ‫‪.5‬‬ ‫‪14 . 33‬‬
‫‪B‬‬ ‫‪1265‬‬ ‫‪21637‬‬ ‫‪17 . 1‬‬
‫‪C‬‬ ‫‪2475‬‬ ‫‪50177‬‬ ‫‪20 . 27‬‬
‫‪TOTAL‬‬ ‫‪4942‬‬ ‫‪89050‬‬

‫‪AVERAGE LINE ONE‬‬ ‫‪= 18 . 01 ( KG‬‬ ‫) ‪/ M‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ٥‬ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ ﻻﻳﻦ ‪ ٣‬ﮔﺎﻟﺮﻱ ‪ ٨٥٠‬ﭼﭗ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ‫‪٥٧٤‬‬

‫ﺏ‪ -‬ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ : ٧٩٥‬ﻣﺠﻤـﻮﻉ ﻋﻤﻠﻴﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺩﺭ ﺭﺩﻳﻒ ﺍﻭﻝ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺷﺎﻣﻞ ‪ ٢٥٤٤٥‬ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﻭ ‪ ٣٥٧٠٠٣‬ﻛﻴﻠﻮﮔﺮﻡ‬
‫ﺳـﻴﻤﺎﻥ ﺗـﺰﺭﻳﻖ ﺷـﺪﻩ ﻣـﻲ ﺑﺎﺷـﺪ‪،‬ﻻﻳﻪ ﻫـﺎﻱ ﻣﻮﺟﻮﺩ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﻛﻪ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ ﺩﺭ ﺍﻧﻬﺎ ﺍﻧﺠﺎﻡ ﻣﻲ ﺷﻮﺩ ﻭﺍﺣﺪ ﻫﺎﻱ ‪ 4a2‬ﻭ‬
‫‪ 4a3‬ﺳـﺎﺯﻧﺪ ﺍﺳـﻤﺎﺭﻱ ﻣـﻲ ﺑﺎﺷـﻨﺪ‪ .‬ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ﺩﺭ ﺍﻳﻦ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ‪ ١٤٨‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻭ ﺭﺩﻳﻒ ﺩﻭﻡ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺷﺎﻣﻞ ‪١٤٥١٥‬‬
‫ﻣﺘﺮ ﺣﻔﺎﺭﻱ ﻭ ‪ ١٠٣٦٥٧٦‬ﻛﻴﻠﻮﮔﺮﻡ ﺳﻴﻤﺎﻥ ﻣﺼﺮﻓﻲ ) ﺗﺰﺭﻳﻖ ﺷﺪﻩ ( ﺑﻮﺩﻩ ﻛﻪ ﺩﺍﺭﺍﻱ ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ‪ ٧٢‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ‬
‫ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫ﻣﻄﺎﻟﻌـﻪ ﻧـﺘﺎﻳﺞ ﺗﺰﺭﻳﻖ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺭﺩﻳﻒ ﺍﻭﻝ ﭘﺮﺩﻩ ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﻧﺸﺎﻧﮕﺮ ﺳﻴﺮ ﻧﺰﻭﻟﻲ ﺧﻮﺭﻧﺪ ﺍﺯ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪) A‬ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ‬
‫‪ ٤٠٤‬ﻛـﻴﻠﻮ ﮔـﺮﻡ ﺩﺭ ﻣـﺘﺮ ﻃـﻮﻝ ﮔﻤﺎﻧـﻪ( ‪ ،‬ﺳـﺮﻱ ‪ ) B‬ﻣﺘﻮﺳـﻂ ﺧﻮﺭﻧﺪ ‪ ٢٧٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ( ‪ ،‬ﺳﺮﻱ ‪) C‬ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ ‪١٢٩‬‬
‫ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ( ‪ ،‬ﺳﺮﻱ ‪) D‬ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ ‪ ٦٥‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ( ﻭ ﺳﺮﻱ ‪ ) E‬ﻣﺘﻮﺳﻂ ﺧﻮﺩﺭﻧﺪ ‪ ٤٠‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ‬
‫ﻣـﺘﺮ ﻃـﻮﻝ ﮔﻤﺎﻧـﻪ ( ﻣـﻲ ﺑﺎﺷـﻨﺪ‪.‬ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ ٧‬ﻭ ﻧﻤﻮﺩﺍﺭ ﺷﻤﺎﺭﻩ ‪ ٩‬ﻭ ﻫﻤﭽﻨﻴﻦ ﻣﻄﺎﻟﻌﻪ ﻧﺘﺎﻳﺞ ﺗﺰﺭﻳﻖ ﺩﺭ ‪ ٢٥‬ﮔﻤﺎﻧﻪ ﺳﺮﻱ ‪ A‬ﺭﺩﻳﻒ ﺩﻭﻡ ﭘﺮﺩﻩ‬
‫ﻭﺍﻗـﻊ ﺩﺭ ﺍﻳـﻦ ﮔﺎﻟـﺮﻱ ﻣﺘﻮﺳـﻂ ﺧﻮﺭﻧﺪ ‪ ٧٥‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻭ ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ ﺩﺭ ‪ ٢٣‬ﮔﻤﺎﻧﻪ ﺍﺟﺮﺍ ﺷﺪﻩ ﺳﺮﻱ ‪ B‬ﺣﺪﻭﺩ ‪ ٨٥‬ﻛﻴﻠﻮ‬
‫ﮔـﺮﻡ ﺩﺭ ﻣـﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻭ ﻣﺘﻮﺳﻂ ﺧﻮﺭﻧﺪ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ C‬ﺣﺪﻭﺩ ‪ ٧٥‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺍﺟﺮﺍ ﺷﺪﻩ ﺳﺮﻱ‬
‫‪ D‬ﻣﺘﻮﺳـﻂ ﺧﻮﺭﻧـﺪ ﺣـﺪﻭﺩ ‪ ٦٥‬ﻛـﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣـﺘﺮ ﻃـﻮﻝ ﮔﻤﺎﻧﻪ ﺭﺍ ﻧﺸﺎﻥ ﻣﻲ ﺩﻫﺪ ﻛﻪ ﺩﻻﻳﻞ ﻋﻤﺪﻩ ﺍﻳﻦ ﻣﺴﺎﻟﻪ ) ﻧﺰﺩ ﻳﻜﻲ ﻣﻴﺰﺍﻥ ﺧﻮﺭﻧﺪ ﻫﺎﻱ‬
‫ﮔﻤﺎﻧـﻪ ﻫـﺎﻱ ﺳـﺮﻱ ‪ C ، B ، A‬ﻭ ‪ ( D‬ﻣـﺮﺑﻮﻁ ﺑـﻪ ﺗﻐﻴـﻴﺮ ﺯﺍﻭﻳـﻪ ﻭ ﺍﺯﻳﻤـﻮﺕ ﮔﻤﺎﻧـﻪ ﻫـﺎ ﻭ ﺍﺣـﺘﻤﺎﻝ ﺧﺮﻭﺝ ﻣﺴﻴﺮ ﺣﻔﺎﺭﻱ ﺍﺯ ﻣﺴﻴﺮ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ‬
‫ﺑﺨﺼﻮﺹ ﺩﺭ ﺍﺧﺮﻳﻦ ﻣﻘﺎﻃﻊ ﺣﻔﺎﺭﻱ ﻛﻪ ﻃﺒﻖ ﮔﺰﺍﺭﺷﺎﺕ ﻣﻮﺟﻮﺩ ﻋﻤﺪﻩ ﻧﻔﻮﺫ ﭘﺬﻳﺮﻱ ﻫﺎ ﺍﺯ ﻋﻤﻖ ‪ ٨٠‬ﺗﺎ ‪ ١٠٠‬ﻣﺘﺮﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ﺑﻮﺩﻩ ﺍﺳﺖ ‪ .‬ﻧﺘﺎﻳﺞ‬
‫ﻓﻮﻕ ﺩﺭ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ ٨‬ﺍﻣﺪﻩ ﺍﺳﺖ ‪.‬‬
‫‪LINE‬‬ ‫‪DRILLING‬‬ ‫‪GROUITNG‬‬ ‫‪AVERAGE LINE‬‬
‫‪2‬‬ ‫‪7080‬‬ ‫‪862698‬‬ ‫‪121.85‬‬
‫‪3‬‬ ‫‪4942‬‬ ‫‪89050.5‬‬ ‫‪18.01‬‬
‫‪TOTAL‬‬ ‫‪12022‬‬ ‫‪951748.5‬‬ ‫‪79.16‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ۶‬ﻣﻴﺎﻧﮕﻴﻦ ﺧﻮﺭﻧﺪ ﻻﻳﻦ ﻫﺎﻱ ‪ ۲‬ﻭ ‪ ۳‬ﮔﺎﻟﺮﻱ ‪ ۸۵۰‬ﭼﭗ‬

‫ﺑﺮﺭﺳـﻲ ﻧـﺘﺎﻳﺞ ﺗـﺰﺭﻳﻖ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺍﺟﺮﺍ ﺷﺪﻩ ﺩﺭ ﺩﻭ ﺭﺩﻳﻒ ﭘﺮﺩﻩ ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﻧﺸﺎﻥ ﻣﻲ ﺩﻫﺪ ﻛﻪ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺩﺭ ﺭﺩﻳﻒ ﺍﻭﻝ ﺑﺎ ﺍﺟﺮﺍﻱ‬
‫ﮔﻤﺎﻧـﻪ ﻫـﺎﻱ ﺳﺮﻱ ‪ E‬ﻛﻪ ﺍﺯ ﻟﺤﺎﻅ ﺍﻣﺘﺪﺍﺩ ﻭ ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﻣﺸﺎﺑﻪ ﺑﺎ ﺳﺎﻳﺮ ﺳﺮﻱ ﻫﺎﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺍﻳﻦ ﺭﺩﻳﻒ ﺑﻮﺩﻩ ﺍﺳﺖ ﺑﺎ ﺧﻮﺭﻧﺪ ﻣﺘﻮﺳﻂ ‪٤٠‬‬
‫ﻛـﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣـﺘﺮ ﻃـﻮﻝ ﮔﻤﺎﻧـﻪ ﺍﺯ ﻣﻌـﻴﺎﺭ ﭘﻴﺸﻨﻬﺎﺩﻱ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﻛﻤﺘﺮ ﺑﻮﺩﻩ ﻭ ﺑﻨﻈﺮﺑﺎ ﺍﺻﻼﺡ ﺭﻭﺵ ﻫﺎﻱ ﺍﺟﺮﺍﻳﻲ ﺍﺯ ﻗﺒﻴﻞ ﺗﺠﺪﻳﺪ ﻧﻈﺮ ﺩﺭ‬
‫ﻓﺸـﺎﺭﻫﺎﻱ ﺗﺰﺭﻳﻖ ﻭ ﺍﺭﺍﺋﻪ ﺍﻣﺘﺪﺍﺩ ﻭ ﺯﺍﻭﻳﻪ ﻣﻨﺎﺳﺐ ﺑﺮﺍﻱ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ) ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺳﻴﺴﺘﻢ ﻧﺎﭘﻴﻮﺳﺘﮕﻲ ﻫﺎﻱ ﺍﺻﻠﻲ ﻣﻮﺟﻮﺩ ﺩﺭ ﺍﻳﻦ ﺑﺨﺶ ﺍﺯ‬
‫ﭘﺮﺩﻩ ( ﻣﻴﺘﻮﺍﻧﺴﺘﻴﻢ ﺑﻪ ﻣﻌﻴﺎﺭ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﺩﺭ ﻫﻤﺎﻥ ﺭﺩﻳﻒ ﺍﻭﻝ ﻭ ﻳﺎ ﺣﺪﺍﻛﺜﺮ ﺑﺎ ﺍﺟﺮﺍﻱ ﺳﺮﻱ ﺍﻭﻝ ﻭ ﺩﻭﻡ ﺩﺭ ﭘﺮﺩﻩ ﺩﻭﻡ ﺑﻪ ﺍﺑﺒﻨﺪﻱ ﻣﻮﺭﺩ ﻧﻈﺮ ﻭ‬
‫ﻗﺎﺑﻞ ﻗﺒﻮﻝ ﺩﺳﺖ ﻳﺎﻓﺖ ‪.‬‬
‫ﻣﺸﺨﺼـﺎﺕ ﻧﺎﭘﻴﻮﺳﺘﮕﻲ ﻫﺎﻱ ﺍﺻﻠﻲ ﻭ ﻣﻮﺛﺮ ﺩﺭ ﺗﺰﺭﻳﻖ ﭘﺬﻳﺮﻱ ﻗﺒﻞ ﺍﺯ ﭘﻮﺷﺶ ﺑﺘﻨﻲ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺍﻧﺠﺎﻡ ﮔﺮﺩﻳﺪ ﻛﻪ ﻣﻬﻤﺘﺮﻳﻦ ﺧﺼﻮﺻﻴﺎﺕ‬
‫ﺍﻳـﻦ ﻧﺎﭘﻴﻮﺳﺘﮕﻲ ﻫﺎ ﺩ ﺭﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ ٩‬ﻭ ‪ ١٠‬ﻭ ﺷﻜﻞ ﺷﻤﺎﺭﻩ ‪ ٢‬ﺑﺼﻮﺭﺕ ﺑﻠﻮﻙ ﺩﻳﺎﮔﺮﺍﻡ ﻭ ﺷﻜﻞ ﺷﻤﺎﺭﻩ ‪ ٣‬ﺑﺼﻮﺭﺕ ﻧﻤﻮﺩﺍﺭﺍﺳﺘﺮﻳﻮﻧﺖ ﻧﺸﺎﻥ‬
‫ﺩﺍﺩﻩ ﺷﺪﻩ ﺍﺳﺖ ‪ .‬ﻫﻤﭽﻨﻴﻦ ﺗﺼﺎﻭﻳﺮ ‪ ١‬ﺗﺎ ‪ ٦‬ﻣﻮﻗﻌﻴﺖ ﺗﻌﺪﺍﺩﻱ ﺍﺯ ﻧﺎﭘﻴﻮﺳﺘﮕﻲ ﻫﺎ ﻭ ﺣﺎﻟﺖ ﭘﺮ ﺷﺪﮔﻲ ﺍﻧﻬﺎ ﺑﻮﺳﻴﻠﻪ ﺩﻭﻏﺎﺏ ﺗﺰﺭﻳﻖ ﺍﺯ ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ‬
‫ﺗﺮﺍﺯ ‪ ٨٥٠‬ﺭﺍ ﻧﺸﺎﻥ ﻣﻴﺪﻫﺪ‪.‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٧٥‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﺸﺮﺡ ﺯﻳﺮ ﺑﻮﺩﻩ ﺍﺳﺖ ‪:‬‬


‫‪ -‬ﺭﻭﺵ ﺗـﺰﺭﻳﻖ‪ ،‬ﺑﺼـﻮﺭﺕ ﻣﺘﻌﺎﺭﻑ ﺑﺎ ﻧﺼﺐ ﭘﻜﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ) ﺑﺠﺰ ﺩﺭ ﻣﻮﺍﺭﺩ ﮔﻤﺸﺪﮔﻲ ﺍﺏ ﺩﺭ ﺩﺍﺧﻞ ﮔﻤﺎﻧﻪ ﻛﻪ ﺗﺰﺭﻳﻖ ﺑﻪ ﺭﻭﺵ ﺍﺯ ﺑﺎﻻ‬
‫ﺑﻪ ﭘﺎﺋﻴﻦ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ (‪.‬‬
‫‪ -‬ﻓﺸﺎﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﺩﺭ ﺗﻤﺎﻣﻲ ﺳﺮﻱ ﻫﺎ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎ ﺣﺪﺍﻛﺜﺮ ‪ ٣٠‬ﺑﺎﺭ ﻭ ﺑﺮﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ ٣‬ﻣﻲ ﺑﺎﺷﺪ‬
‫‪ -‬ﺣﺪﺍﻛﺜﺮ ﻋﻤﻖ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ١١٥‬ﻣﺘﺮ‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎﺩﺭ ﭘﺮﺩﻩ ﺍﻭﻝ ‪ ٢٣‬ﺩﺭﺟﻪ ‪ ،‬ﺩﺭ ﭘﺮﺩﻩ ﺩﻭﻡ ‪ ٢٨‬ﺩﺭﺟﻪ ﻭ ﺩﺭ ﭘﺮﺩﻩ ﺳﻮﻡ ‪ ٢٩‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ‬
‫‪ -‬ﺍﺯﻳﻤﻮﺕ ﺩﺭﭘﺮﺩﻩ ﺍﻭﻝ ‪ ، N45‬ﺩﺭ ﭘﺮﺩﻩ ﺩﻭﻡ‪ N135‬ﻭ ﺩﺭﭘﺮﺩﻩ ﺳﻮﻡ ‪N75‬‬
‫‪ -‬ﻣﺼﺎﻟﺢ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﻭﻏﺎﺏ ﺳﻴﻤﺎﻥ ﺑﺎ ﺍﺏ ﺑﻪ ﻧﺴﺒﺖ ﺍﺏ ‪ :‬ﺳﻴﻤﺎﻥ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ ١/٥ :١ ، ١:١ ، ١:١/٥ ، ١:٢‬ﻭ‪٢:١‬‬
‫‪SERIIES‬‬ ‫‪DRILLING‬‬ ‫‪GROUTING‬‬ ‫‪AVERAGE‬‬
‫‪A‬‬ ‫‪3305.3‬‬ ‫‪1336096‬‬ ‫‪404.23‬‬
‫‪B‬‬ ‫‪3135‬‬ ‫‪649562‬‬ ‫‪207.2‬‬
‫‪C‬‬ ‫‪6270‬‬ ‫‪813990‬‬ ‫‪129.82‬‬
‫‪D‬‬ ‫‪10630‬‬ ‫‪687699‬‬ ‫‪64.7‬‬
‫‪E‬‬ ‫‪2115‬‬ ‫‪83656‬‬ ‫‪39.55‬‬
‫‪TOTAL‬‬ ‫‪2445.3‬‬ ‫‪3571003‬‬

‫‪AVERAGE LINE ONE‬‬


‫)‪= 140.285( KG/ M‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ٧‬ﻧﺘﺎﻳﺞ ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ ﻻﻳﻦ ‪ ١‬ﮔﺎﻟﺮﻱ ‪ ٧٩٥‬ﭼﭗ‬

‫‪SERIIES‬‬ ‫‪DRILLING‬‬ ‫‪GROUTING‬‬ ‫‪AVERAGE‬‬


‫‪A‬‬ ‫‪2107‬‬ ‫‪153075‬‬ ‫‪72.65‬‬
‫‪B‬‬ ‫‪2029‬‬ ‫‪171360‬‬ ‫‪84.45‬‬
‫‪C‬‬ ‫‪4035‬‬ ‫‪305837‬‬ ‫‪75.79‬‬
‫‪D‬‬ ‫‪6344‬‬ ‫‪406304‬‬ ‫‪64.04‬‬
‫‪E‬‬ ‫‪0‬‬ ‫‪0‬‬ ‫‪0‬‬
‫‪TOTAL‬‬ ‫‪14515‬‬ ‫‪1036576‬‬

‫) ‪AVERAGE LINE ONE= 71.414 ( KG/ M‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ٨‬ﻧﺘﺎﻳﺞ ﺣﻔﺎﺭﻱ ﻭ ﺗﺰﺭﻳﻖ ﻻﻳﻦ ‪ ٢‬ﮔﺎﻟﺮﻱ ‪ ٧٩٥‬ﭼﭗ‬


‫ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ‬ ‫ﺍﻧﺠﺎﻡ ﺷﺪﻩ‬
‫ﺳﺮﻱ ‪A‬‬ ‫‪330‬‬ ‫‪404 .23‬‬
‫ﺳﺮﻱ ‪B‬‬ ‫‪125‬‬ ‫‪207 .2‬‬
‫ﺳﺮﻱ ‪C‬‬ ‫‪90‬‬ ‫‪129 .82‬‬
‫ﺳﺮﻱ ‪D‬‬ ‫‪45‬‬ ‫‪64 .7‬‬
‫ﺳﺮﻱ ‪E‬‬ ‫‪25‬‬ ‫‪39 .55‬‬

‫‪450‬‬
‫‪400‬‬
‫‪350‬‬
‫‪300‬‬
‫‪250‬‬ ‫ﭘﻴ ﺶ ﺑﻴﻨﻲ ﺷﺪﻩ‬
‫‪200‬‬ ‫اﻧ ﺠﺎم ﺷﺪﻩ‬
‫‪150‬‬
‫‪100‬‬
‫‪50‬‬
‫‪0‬‬
‫ﺑﻮﻙ‬
‫ﺳ ﺮ ي‪A‬‬
‫ﺳﻴﻮﻳﻞ‬
‫ﺳ ﺮ ي‪B‬‬
‫ﺗﻮﺳﻂ‬ ‫ﺩﺍﺩﻩ ﺷﺪﻩ‬
‫ﺳ ﺮ ي‪C‬‬ ‫ﺳﺮ ي‪D‬‬
‫ﮔﺴﺘﺮﺵ‬
‫ﺳﺮ ي‪E‬‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


www.civilbook.ir
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ٥٧٦

JIONT SYSTEM DIP DIP


NO STRICK REMARKS
OTHER PARAMETERS (DEGREE) DIRECTION
NORMALLY BEDDING SURFACE
1 BEDDING N 140 E 80 N 230(SW)
FILLING BY GROUT
/IT IS COMPLETE
J4A
2 N 57 E 75 N 327E(NW) FILLING BY GROUT
/IS NOT COMPLETE
( MAJOR JOINT SET)
J4B
3 N 67 E 80 N 157E(SE) FILLING BY GROUT
/IS NOT COMPLETE
( MAJOR JOINT SET)
GROUT CURATIN AXIS N 135 E 67/65 N45E/N23E WITH TWO DRILLING DIRECTION
ACTUAL DRILLING DIRECTION N 45 E 67(23) NE 23 FROM VERTICAL
( INCLINATION)
4
MODIFICATION
N 23 E 65 ( 65) NE INCLINATION25 FROM VERTICAL
DRILLING DIRECTION

TABLE 9 - GENERAL SPECIFICATION OF JOINTS SETS


/OTHER PARAMETERS AT EL
.795-LEFT BANK GROUT CURTA

JOINT DIP DIP REMARK


NO STRICK
SYSTEM (DEGREE) DIRECTION (DESCRIPTION )
1 BEEDING N135E 85 N225E DOWN STREAM WALL . KM 0+42
UP STREAM WALL.KM0+117
2 BEEDING N145E 80 N235E
BEEDING SURFACE DRILLING BY GROUT
J4A UP STREAM WALL .KM0+65
3 N40E 67 N310E
SET OPENNING ABOUT40 CM
J4A DOWN STREAM WALL .KM0+87
4 N50E 75 N230E
SET OPENNING ABOUT2 CM
J4A DOWN STREAM WALL
5 N15E 75 N315E
SET OPENNING20 TO 50 CM … CRASHED ZONE
J4A DOWN STREAM WALL .KM0+156
6 N70E 86 N340E
SET CRASHED ZONE ABOUT 2 TO 5 CM WIDTH
J4A DOWN STREAM WALL .KM 0+162
7 N75E 71 N345E
SET OPENNING2 TO 5 CM
J4B UP STREAM /DOWN STREAM WALL .KM 0+126
8 N 60 E 83 N 150E
SET CRASHEDZONE ABOUT2 M - OPENNING40 TO 60 CM
J4B UP STREAM WALL.KM 0+137
9 N 90 E 88 N 180E
SET OPENNING20 TO 30 CM
J4B DOWN STREAM WALL .KM 0+177
10 N 50 E 68 N 140 E
SET FILLING BY GROUT ABOUT30 CM - CRASHED ZONE
GOU.CUR.
11 N 135 E 67(23) NE ACTUAL FROUT CURTAIN
AXIS
DRILLING
12 N 45 E 67 ( 23 ) NE INCLINATION23 , FROM VERTICAL
DIRECTION

TABLE NO10 - SOACIFICATION OF JOINTS SET AT.795


EL LEFT BANK GROUTING GALLERY

: ‫ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﺍﻃﺮﺍﻑ ﻧﻴﺮﻭﮔﺎﻩ‬- ٥ - ٢


‫ ﻣﺘﺮ ﻭ ﻛﻞ ﺳﻴﻤﺎﻥ ﺗﺰﺭﻳﻖ ﺷﺪﻩ‬٣٧٣٦٩ ‫ ﻣﺠﻤﻮﻉ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﺍﻧﺠﺎﻡ ﺷﺪﻩ‬: ‫ ﺷﻤﺎﻝ ﻧﻴﺮﻭﮔﺎﻩ‬٦٦٠ ‫ ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ‬- ‫ﺍﻟـﻒ‬
‫ ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ ﺑﺨﺶ ﻋﻤﻠﻴﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ‬١٦٠ ‫ ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ﺣﺪﻭﺩ‬، ‫ ﻛـﻴﻠﻮﮔﺮﻡ ﻣـﻲ ﺑﺎﺷـﺪ‬٥٩٩٦٤٨٤
‫ ﺩﺭ ﺻﺪ ﺑﺎﻗﻴﻤﺎﻧﺪﻩ ﻋﻤﻠﻴﺎﺕ‬٢٠ ‫ ﺩﺭﺻﺪ ﻋﻤﻠﻴﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﻣﻲ ﺑﺎﺷﺪ ﻭ ﺣﺪﻭﺩ‬٨٠ ‫( ﻛﻪ ﺣﺪﻭﺩ‬4a1 ‫ ﻭ‬4a2 ‫ﺩﺭ ﺳﺎﺯﻧﺪ ﺍﻫﻚ ﺍﺳﻤﺎﺭﻱ ) ﺑﺨﺶ‬
.‫ ( ﺍﺳﻤﺎﺭﻱ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ‬RED BED ) ‫ ﺷﻴﻠﻲ ﭘﺎﺑﺪﻩ ﻭ ﺍﻫﻚ ﺭﺳﻲ‬-‫ﺩﺭ ﺳﺎﺯﻧﺪ ﻣﺎﺭﻧﻲ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com


www.civilbook.ir
٥٧٧ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com


www.civilbook.ir
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ٥٧٨

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com


‫‪www.civilbook.ir‬‬
‫‪٥٧٩‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﺩﺭ ﺑﺮﺭﺳﻲ ﻧﺘﺎﻳﺞ ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ‪ ١١ ، ١٠‬ﻭ ‪ ١٢‬ﻧﺸﺎﻥ ﻣﻴﺪﻫﺪ ﻛﻪ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ D‬ﺑﻤﻌﻴﺎﺭ ﻣﻮﺭﺩ ﻧﻈﺮ ﺭﺳﻴﺪﻩ ﻭ ﺍﺟﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﻣﺎﺯﺍﺩ )‬
‫ﺳﺮﻱ ‪ (E‬ﻣﻨﺘﻔﻲ ﺑﻮﺩﻩ ﺍﺳﺖ ‪.‬‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﻣﻲ ﺑﺎﺷﺪ‪:‬‬


‫‪ -‬ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﺭﻭﺵ ﺟﻴﻦ ) ﺩﻭﻏﺎﺏ ﺗﻚ ﻏﻠﻈﺘﻲ ( ﺑﺮ ﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪١١‬‬
‫‪ -‬ﻓﺸﺎﺭﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺑﺮ ﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪١٢‬‬
‫‪ -‬ﻧﺴﺒﺖ ﺩﻭﻏﺎﺏ ﻫﺎﻱ ﺗﺰﺭﻳﻘﻲ ﺑﺮ ﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪١٣‬‬
‫‪ -‬ﺍﺭﺍﻳﺶ ﭼﺎﻟﻬﺎ ﺑﺎ ﻓﺎﺻﻠﻪ ﮔﺬﺍﺭﻱ ﺑﻴﻦ ﮔﻤﺎﻧﻪ ﻫﺎ ﺑﺮ ﺍﺳﺎﺱ ﺷﻜﻞ ﺷﻤﺎﺭﻩ ‪٤‬‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ٢٠‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ‬
‫ﻣﻘﺪﺍﺭ ﻋﺪﺩ ﺟﻴﻦ‬ ‫ﻣﺎﻛﺰﻳﻤﻢ ﺧﻮﺭﻧﺪ‬
‫ﻋﻤﻖ ) ﻣﺘﺮ (‬
‫)ﺑﺎﺭ ﺩﺭ ﻟﻴﺘﺮ ﺑﺮ ﻣﺘﺮ (‬ ‫)ﻛﻴﻠﻮﮔﺮﻡ ﺳﻴﻤﺎﻥ ﺩﺭ ﻣﺘﺮ (‬
‫‪0- 5‬‬ ‫‪500‬‬ ‫‪800‬‬
‫‪5 - 10‬‬ ‫‪1500‬‬ ‫‪1000‬‬
‫‪> 10‬‬ ‫‪2500‬‬ ‫‪1500‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ۱۱‬ﺭﻭﺵ ﺟﻴﻦ ) ﺩﻭﻏﺎﺏ ﺗﻚ ﻏﻠﻈﺘﻲ (‬

‫‪W/C‬‬ ‫‪KG Cement / Lit‬‬


‫‪0.5‬‬ ‫‪1.22‬‬
‫‪0.6‬‬ ‫‪1.09‬‬
‫‪0.65‬‬ ‫‪1.03‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ۱۳‬ﻧﺴﺒﺖ ﻫﺎﻱ ﺗﺰﺭﻳﻘﻲ ﺩﻭﻏﺎﺏ ﺩﺭ ﮔﺎﻟﺮﻱ ‪ ۶۶۰‬ﺷﻤﺎﻝ ﻧﻴﺮﻭﮔﺎﻩ‬

‫ﻓﺸﺎﺭ ) ﺑﺎﺭ ( ﻋﻤﻖ ) ﻣﺘﺮ (‬ ‫ﻓﺸﺎﺭ ) ﺑﺎﺭ ( ﻋﻤﻖ ) ﻣﺘﺮ (‬


‫‪0_5‬‬ ‫‪1.5‬‬ ‫‪25_30‬‬ ‫‪15‬‬
‫‪5_10‬‬ ‫‪3.5‬‬ ‫‪30_35‬‬ ‫‪18‬‬
‫‪10_15‬‬ ‫‪6‬‬ ‫‪35_40‬‬ ‫‪21‬‬
‫‪15_20‬‬ ‫‪9‬‬ ‫‪> 40‬‬ ‫‪25‬‬
‫‪20_25‬‬ ‫‪12‬‬

‫ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ - ۱۲‬ﻓﺸﺎﺭﻫﺎﻱ ﺗﺰﺭﻳﻖ ﺩﺭ ﮔﺎﻟﺮﻱ ‪ ۶۶۰‬ﺷﻤﺎﻝ ﻧﻴﺮﻭﮔﺎﻩ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


www.civilbook.ir
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ٥٨٠

SERIES DRILING SERIES GROUITNG SERIES KG/M


A 2517 A 899072.4 A 357.2
B 2542 B 375707.6 B 147.8
C 4986 C 288689.4 C 57.9
D 5405 D 170798 D 31.6
E 3688 E 73760 E 20
DRILING GROUITNG KG/M

6000 1000000 400

900000 350
5000
800000
300
700000
4000
250
600000

3000 DRILING 500000 GROUITNG 200 KG/M

400000
150
2000
300000
100
200000
1000
50
100000

0 0 0
A B C D E A B C D E A B C D E

‫ﺷﻤﺎل ﻧﻴﺮوﮔﺎﻩ‬660 ‫ﻧﺘﺎﻳﺞ ﻣﺮﺑﻮط ﺑﻪ ﺗﺰرﻳﻘﺎت ﮔﺎﻟﺮي‬- 12 ‫ و‬11 ، 10 ‫ﻧﻤﻮدارهﺎي ﺷﻤﺎرﻩ‬

( ‫ ) ﻣﻮﺍﺯﻱ ﻣﺤﻮﺭ ﮔﺎﻟﺮﻱ‬N50 "‫ ﺍﺯﻳﻤﻮﺕ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎ ﺗﻘﺮﻳﺒﺎ‬-

SERIES DRILING SERIES GROUITNG SERIES KG/M


A 1930 A 677700.2 A 351.14
B 1625 B 222852.5 B 137.14
C 3170 C 221900 C 70
D 1635 D 12753 D 7.8
DRILING GROUITNG KG/M

3500 800000 400

700000 350
3000

600000 300
2500

500000 250
2000

DRILING
400000 GROUITNG 200 KG/M

1500

300000 150

1000

200000 100

500

100000 50

0
A B C D 0 0
A B C D A B C D

‫ ﺟﻨﻮﺏ ﻧﻴﺮﻭﮔﺎﻩ‬٦٦٠ ‫ ﻧﺘﺎﻳﺞ ﺗﺰﺭﻳﻘﺎﺕ ﮔﺎﻟﺮﻱ‬- ١٥ ‫ ﻭ‬١٤ ، ١٣ ‫ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ﺷﻤﺎﺭﻩ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com


‫‪www.civilbook.ir‬‬
‫‪٥٨١‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫‪8m‬‬
‫‪4m‬‬
‫‪2m‬‬
‫‪1m‬‬
‫‪0.5 m‬‬

‫‪A‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪C‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪B‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪C‬‬ ‫‪E‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪A‬‬

‫ﺏ‪ -‬ﮔﺎﻟـﺮﻱ ﺗـﺰﺭﻳﻖ ‪ ٦٦٠‬ﺟـﻨﻮﺏ ﻧﻴﺮﻭﮔﺎﻩ ‪ :‬ﻣﺠﻤﻮﻉ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ‪ ١٢٣٢٣‬ﻣﺘﺮ ﻭ ﻛﻞ ﺳﻴﻤﺎﻥ ﺗﺰﺭﻳﻖ ﺷﺪﻩ ‪١٤٤٥٧١٣‬‬
‫ﻛﻴﻠﻮﮔﺮﻡ ﻣﻲ ﺑﺎﺷﺪ ‪ ،‬ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ‪ ١١٧‬ﻛﻴﻠﻮﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﺍﺳﺖ ﻛﻪ ﺩﺭ ﺳﻪ ﺑﺨﺶ ﺍﻫﻚ ﻫﺎﻱ ﺍﺳﻤﺎﺭﻱ )‬
‫‪ 4a1‬ﻭ ‪ (4a2‬ﻛﻪ ‪ ٧٠‬ﺩﺭﺻﺪ ﻋﻤﻠﻴﺎﺕ ﺭﺍ ﺷﺎﻣﻞ ﻣﻲ ﺷﻮﺩ ﻭ ﺑﺎﻗﻴﻤﺎﻧﺪﻩ ﻋﻤﻠﻴﺎﺕ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺣﺪﻭﺩ ‪ ٣٠‬ﺩﺭ ﺻﺪ ﺩﺭ ﺳﺎﺯﻧﺪ ﻣﺎﺭﻧﻲ – ﺷﻴﻠﻲ ﭘﺎﺑﺪﻩ‬
‫ﻭ ﺍﻫـﻚ ﻫـﺎﻱ ﺭﺳـﻲ ) ‪ (Red Bed‬ﺍﺳـﻤﺎﺭﻱ ﺍﻧﺠـﺎﻡ ﺷﺪﻩ ﺍﺳﺖ ‪ .‬ﺑﺮﺭﺳﻲ ﻧﺘﺎﻳﺞ ﻧﻤﻮﺩﺍﺭ ﺷﻤﺎﺭﻩ ﻫﺎﻱ ‪ ١٤ ، ١٣‬ﻭ ‪ ١٥‬ﻛﻪ ﺍﻣﺎﺭﻫﺎ ﻭ ﺍﻃﻼﻋﺎﺕ‬
‫ﻣـﺮﺑﻮﻁ ﺑـﻪ ﺑﺨـﺶ ﺍﺳﻤﺎﺭﻱ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺭﺍ ﻧﺸﺎﻥ ﻣﻴﺪﻫﺪ ﺑﻴﺎﻧﮕﺮ ﺍﻳﻦ ﻧﻜﺘﻪ ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﺩﺭ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ C‬ﺣﺎﺻﻞ ﺷﺪﻩ ﻭ‬
‫ﻧﻴﺎﺯﻱ ﺑﻪ ﺍﺟﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ D‬ﺑﺎ ﺣﺠﻢ ﺍﺟﺮﺍ ﺷﺪﻩ ﻧﺒﻮﺩﻩ ﺍﺳﺖ ‪.‬‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﺸﺮﺡ ﺯﻳﺮ ﺑﻮﺩﻩ ﺍﺳﺖ ‪:‬‬


‫‪ -‬ﺭﻭﺵ ﺗـﺰﺭﻳﻖ‪ ،‬ﺑﺼـﻮﺭﺕ ﻣﺘﻌﺎﺭﻑ ﺑﺎ ﻧﺼﺐ ﭘﻜﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ) ﺑﺠﺰ ﺩﺭ ﻣﻮﺍﺭﺩ ﮔﻤﺸﺪﮔﻲ ﺍﺏ ﺩﺭ ﺩﺍﺧﻞ ﮔﻤﺎﻧﻪ ﻛﻪ ﺗﺰﺭﻳﻖ ﺑﻪ ﺭﻭﺵ ﺍﺯ ﺑﺎﻻ‬
‫ﺑﻪ ﭘﺎﺋﻴﻦ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ (‪.‬‬
‫‪ -‬ﻓﺸﺎﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﺩﺭ ﺗﻤﺎﻣﻲ ﺳﺮﻱ ﻫﺎ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎ ﺣﺪﺍﻛﺜﺮ ‪ ٢٥‬ﺑﺎﺭ ﻭ ﺑﺮﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪ ١٣‬ﻣﻲ ﺑﺎﺷﺪ‪.‬‬
‫‪ -‬ﺣﺪﺍﻛﺜﺮ ﻋﻤﻖ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ٧٥‬ﻣﺘﺮ‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎﺩﺭﺍﻳﻦ ﭘﺮﺩﻩ ‪ ٢٠‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ ﻣﻲ ﺑﺎﺷﺪ‬
‫‪ -‬ﺍﺯﻳﻤﻮﺕ ﺩﺭ ﺍﻳﻦ ﭘﺮﺩﻩ ‪ ) N88‬ﺗﻘﺮﻳﺒﺎ" ﻣﻮﺍﺯﻱ ﺑﺎ ﻣﺤﻮﺭ ﮔﺎﻟﺮﻱ (‪.‬‬
‫‪ -‬ﻣﺼﺎﻟﺢ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﻭﻏﺎﺏ ﺳﻴﻤﺎﻥ ﺑﺎ ﺍﺏ ﺑﻪ ﻧﺴﺒﺖ ﺍﺏ ‪ :‬ﺳﻴﻤﺎﻥ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ ١/٥ :١ ، ١:١ ، ١:١/٥ ، ١:٢‬ﻭ‪٢:١‬‬

‫ﺝ ‪ -‬ﮔﺎﻟﺮﻱ ﺗﺰﺭﻳﻖ ﺗﺮﺍﺯ ‪ ٦٧١‬ﺷﺮﻕ ﻧﻴﺮﻭﮔﺎﻩ ‪ :‬ﺟﻤـﻊ ﻛﻞ ﺣﻔﺎﺭﻱ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺗﺎ ﺗﺎﺭﻳﺦ ﺗﻬﻴﻪ ﮔﺰﺍﺭﺵ ) ﻣﻬﺮ ﻣﺎﻩ ‪ ١٢٩٥٧ ( ١٣٧٩‬ﻣﺘﺮ ﻭ‬
‫ﺳـﻴﻤﺎﻥ ﺗـﺰﺭﻳﻖ ﺷـﺪﻩ ‪ ١٨٠٤٦٩٥‬ﻛـﻴﻠﻮﮔﺮﻡ ﻣـﻲ ﺑﺎﺷـﺪ ﻛﻪ ﺣﺪﻭﺩ ‪ ٦٠‬ﺩﺭﺻﺪ ﻋﻤﻠﻴﺎﺕ ﻓﻮﻕ ﺩﺭ ﺍﻫﻚ ﺍﺳﻤﺎﺭﻱ ﻭ ﺣﺪﻭﺩ ‪ ٤٠‬ﺩﺭﺻﺪ ﺩﺭ ﺳﺎﺯﻧﺪ‬
‫ﭘﺎﺑﺪﻩ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﻭ ﺩﺭ ﻣﺠﻤﻮﻉ ﻣﺘﻮﺳﻂ ﺟﺬﺏ ﺩﻭﻏﺎﺏ ‪ ١٣٩‬ﻛﻴﻠﻮ ﮔﺮﻡ ﺩﺭ ﻣﺘﺮ ﻃﻮﻝ ﮔﻤﺎﻧﻪ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬

‫ﻧـﺘﺎﻳﺞ ﺑﺪﺳـﺖ ﺍﻣـﺪﻩ ﺍﺯ ﺗـﺰﺭﻳﻖ ﺩﺭ ﮔﻤﺎﻧـﻪ ﻫﺎﻱ ﻣﺨﺘﻠﻒ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺩﺭ ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ‪ ١٧ ، ١٦‬ﻭ ‪ ١٨‬ﻧﺸﺎﻥ ﺩﺍﺩﻩ ﺷﺪﻩ ﺍﺳﺖ ﻧﺘﺎﻳﺞ ﻓﻮﻕ‬
‫ﺣﺎﻛﻲ ﺍﺯ ﺍﻳﻦ ﺍﺳﺖ ﻛﻪ ﺑﺎ ﺍﺟﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ C‬ﺩﺭ ﺍﻳﻦ ﭘﺮﺩﻩ ﺑﻪ ﻣﻌﻴﺎﺭ ﻛﻔﺎﻳﺖ ﺍﺑﺒﻨﺪﻱ ﺩﺳﺖ ﻳﺎﻓﺘﻪ ﻭ ﺍﺟﺮﺍﻱ ﮔﻤﺎﻧﻪ ﻫﺎﻱ ﺳﺮﻱ ‪ D‬ﻭ ‪E‬‬
‫ﺑﺎ ﺣﺠﻢ ﺍﺟﺮﺍ ﺷﺪﻩ ﻓﻌﻠﻲ ﻣﻮﺭﺩ ﻧﻴﺎﺯ ﻧﺒﻮﺩﻩ ﺍﺳﺖ ‪.‬‬

‫ﻣﺸﺨﺼﺎﺕ ﺍﺟﺮﺍ ﺩﺭ ﺍﻳﻦ ﮔﺎﻟﺮﻱ ﺑﺸﺮﺡ ﺯﻳﺮ ﺑﻮﺩﻩ ﺍﺳﺖ ‪:‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬ ‫‪٥٨٢‬‬

‫‪ -‬ﺭﻭﺵ ﺗـﺰﺭﻳﻖ‪ ،‬ﺑﺼـﻮﺭﺕ ﻣﺘﻌﺎﺭﻑ ﺑﺎ ﻧﺼﺐ ﭘﻜﺮﺍﺯ ﭘﺎﺋﻴﻦ ﺑﻪ ﺑﺎﻻ ) ﺑﺠﺰ ﺩﺭ ﻣﻮﺍﺭﺩ ﮔﻤﺸﺪﮔﻲ ﺍﺏ ﺩﺭ ﺩﺍﺧﻞ ﮔﻤﺎﻧﻪ ﻛﻪ ﺗﺰﺭﻳﻖ ﺑﻪ ﺭﻭﺵ ﺍﺯ ﺑﺎﻻ‬
‫ﺑﻪ ﭘﺎﺋﻴﻦ ﺍﻧﺠﺎﻡ ﺷﺪﻩ ﺍﺳﺖ (‪.‬‬
‫‪ -‬ﻓﺸﺎﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺟﻬﺖ ﺗﺰﺭﻳﻖ ﺩﺭ ﺗﻤﺎﻣﻲ ﺳﺮﻱ ﻫﺎ ﻭ ﮔﻤﺎﻧﻪ ﻫﺎ ﺣﺪﺍﻛﺜﺮ ‪ ٣٠‬ﺑﺎﺭ ﻭ ﺑﺮﺍﺳﺎﺱ ﺟﺪﻭﻝ ﺷﻤﺎﺭﻩ ‪٣‬‬
‫‪ -‬ﺣﺪﺍﻛﺜﺮ ﻋﻤﻖ ﮔﻤﺎﻧﻪ ﻫﺎ ‪ ١٠٠‬ﻣﺘﺮ‬
‫‪ -‬ﺯﺍﻭﻳﻪ ﺣﻔﺎﺭﻱ ﮔﻤﺎﻧﻪ ﻫﺎﺩﺭﺍﻳﻦ ﭘﺮﺩﻩ ‪ ٢٠‬ﺩﺭﺟﻪ ﺍﺯ ﻗﺎﺋﻢ ﻣﻲ ﺑﺎﺷﺪ‪.‬‬
‫‪ -‬ﺍﺯﻳﻤﻮﺕ ﺩﺭ ﺍﻳﻦ ﭘﺮﺩﻩ ‪ ) N358‬ﺗﻘﺮﻳﺒﺎ" ﻣﻮﺍﺯﻱ ﺑﺎ ﻣﺤﻮﺭ ﮔﺎﻟﺮﻱ (‬
‫‪ -‬ﻣﺼﺎﻟﺢ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﺩﻭﻏﺎﺏ ﺳﻴﻤﺎﻥ ﺑﺎ ﺍﺏ ﺑﻪ ﻧﺴﺒﺖ ﺍﺏ ‪ :‬ﺳﻴﻤﺎﻥ ﺑﻪ ﺗﺮﺗﻴﺐ ‪ ١/٥ :١ ، ١:١ ، ١:١/٥ ، ١:٢‬ﻭ‪٢:١‬‬

‫‪ -٥-٣‬ﭘـﺮﺩﻩ ﺍﺑﺒـﻨﺪ ﺳﺪ ﭘﺎﺋﻴﻦ ﺩﺳﺖ )‪ : ( T . P . D‬ﺗـﺎ ﺗﺎﺭﻳﺦ ﺗﻬﻴﻪ ﮔﺰﺍﺭﺵ ) ﻣﻬﺮ ﻣﺎﻩ ‪ ( ١٣٧٩‬ﻫﻨﻮﺯ ﻫﻴﭽﮕﻮﻧﻪ ﻋﻤﻠﻴﺎﺕ ﺣﻔﺎﺭﻱ ﻭ‬
‫ﺗﺰﺭﻳﻖ ﺩﺭ ﺍﻳﻦ ﭘﺮﺩﻩ ﺍﻧﺠﺎﻡ ﻧﺸﺪﻩ ﺍﺳﺖ ‪.‬‬

‫‪SERIES‬‬ ‫‪DRILING‬‬ ‫‪SERIES GROUITNG SERIES‬‬ ‫‪KG/M‬‬


‫‪A‬‬ ‫‪2312‬‬ ‫‪A‬‬ ‫‪977068‬‬ ‫‪A‬‬ ‫‪422.6‬‬
‫‪B‬‬ ‫‪1995‬‬ ‫‪B‬‬ ‫‪281818‬‬ ‫‪B‬‬ ‫‪141.26‬‬
‫‪C‬‬ ‫‪3861‬‬ ‫‪C‬‬ ‫‪188165‬‬ ‫‪C‬‬ ‫‪48.73‬‬
‫‪D‬‬ ‫‪2870‬‬ ‫‪D‬‬ ‫‪95653‬‬ ‫‪D‬‬ ‫‪33.32‬‬
‫‪E‬‬ ‫‪1206‬‬ ‫‪E‬‬ ‫‪13344‬‬ ‫‪E‬‬ ‫‪13.55‬‬
‫‪GROUITN‬‬
‫‪DRILING‬‬ ‫‪KG/M‬‬

‫‪1200000‬‬
‫‪4500‬‬ ‫‪450‬‬

‫‪4000‬‬ ‫‪400‬‬
‫‪1000000‬‬

‫‪3500‬‬ ‫‪350‬‬

‫‪800000‬‬
‫‪3000‬‬ ‫‪300‬‬

‫‪2500‬‬ ‫‪250‬‬
‫‪600000‬‬ ‫‪GROUITNG‬‬
‫‪DRILING‬‬ ‫‪KG/M‬‬

‫‪2000‬‬ ‫‪200‬‬

‫‪400000‬‬
‫‪1500‬‬ ‫‪150‬‬

‫‪1000‬‬ ‫‪100‬‬
‫‪200000‬‬

‫‪500‬‬ ‫‪50‬‬

‫‪0‬‬ ‫‪0‬‬ ‫‪0‬‬


‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪D‬‬ ‫‪E‬‬ ‫‪A‬‬ ‫‪B‬‬ ‫‪C‬‬ ‫‪D‬‬ ‫‪E‬‬

‫ﻧﻤﻮﺩﺍﺭﻫﺎﻱ ﺷﻤﺎﺭﻩ ‪ ۱۷ ، ۱۶‬ﻭ ‪- ۱۸‬ﻧﺘﺎﻳﺞ ﺗﺰﺭﻳﻘﺎﺕ ﺩﺭ ﮔﺎﻟﺮﻱ ‪ ۶۷۱‬ﺷﺮﻕ ﻧﻴﺮﻭﮔﺎﻩ‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬


‫‪www.civilbook.ir‬‬
‫‪٥٨٣‬‬ ‫ﭼﻬﺎﺭﻣﻴﻦ ﻛﻨﻔﺮﺍﻧﺲ ﺳﺪﺳﺎﺯﻱ‬

‫ﻧﺘﻴﺠﻪ ﮔﻴﺮﻱ ‪:‬‬

‫ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺍﻃﻼﻋﺎﺕ ﺍﺭﺍﺋﻪ ﺷﺪﻩ ‪ ،‬ﺍﻳﻨﺠﺎﻧﺐ ﺩﻭ ﺳﺌﻮﺍﻝ ﺑﻪ ﺷﺮﺡ ﺯﻳﺮ ﻣﻄﺮﺡ ﻣﻴﻨﻤﺎﻳﻢ ‪:‬‬
‫‪ -١‬ﻣﻌﻴﺎﺭ ﻭ ﻓﺎﻛﺘﻮﺭﻫﺎﻱ ﻣﻮﺛﺮ ﺩﺭ ﻃﺮﺍﺣﻲ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﭼﻨﺪﺭﺩﻳﻔﻪ ﺩﺭ ﺳﺪ ﻛﺎﺭﻭﻥ ‪ ٣‬ﭼﻴﺴﺖ ؟‬
‫‪ -۲‬ﻣﻌـﻴﺎﺭ ﻛﻔﺎﻳـﺖ ﻋﻤـﻖ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ) ﺩﺭ ﭘﻲ ﻭ ﺗﻜﻴﻪ ﮔﺎﻩ ﻫﺎ ( ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺳﺎﺯﻧﺪ ﻫﺎ ﻭ ﺷﺮﺍﻳﻂ ﺯﻣﻴﻦ ﺷﻨﺎﺳﻲ‬
‫ﺳﺎﺧﺘﮕﺎﻩ ﺳﺪ ﻛﺎﺭﻭﻥ ‪ ٣‬ﭼﻴﺴﺖ ؟‬

‫ﺯﻳـﺮﺍ ﺩﺭ ﺻﻮﺭﺕ ﺭﻭﺷﻦ ﻭ ﺷﻔﺎﻑ ﺑﻮﺩﻥ ﺟﻮﺍﺏ ﺳﺌﻮﺍﻻﺕ ﻓﻮﻕ ﺑﻬﺘﺮ ﻣﻴﺘﻮﺍﻥ ﻧﺴﺒﺖ ﺑﻪ ﺗﺠﺰﻳﻪ ﻭ ﺗﺤﻠﻴﻞ ﺍﻃﻼﻋﺎﺕ ﻭ ﻧﺘﺎﻳﺞ ﺑﺪﺳﺖ ﺍﻣﺪﻩ ﺣﻴﻦ‬
‫ﭘﺸﻴﺮﻓﺖ ﻋﻤﻠﻴﺎﺕ ﺍﺟﺮﺍﻳﻲ ﺗﺰﺭﻳﻘﺎﺕ ﭘﺮﺩﻩ ﺍﺑﺒﻨﺪ ﭘﺮﻭﮊﻩ ﻛﺎﺭﻭﻥ ‪ ٣‬ﻧﺘﻴﺠﻪ ﮔﻴﺮﻱ ﻛﺮﺩ‪.‬‬

‫ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺷﺪﻩ ﺗﻮﺳﻂ ﺳﻴﻮﻳﻞ ﺑﻮﻙ‬

‫‪Computer For Civil Software Engineering Group ; www.CCSofts.com , www.CompCivil.com‬‬

You might also like