0% found this document useful (0 votes)
99 views2 pages

SDC40

The SDC40A is a compact digital indicating controller that accepts 4 types of inputs and can be configured using a PC. It has specifications like a memory backup, power consumption of 30VA max, and operating temperature range of 0-50°C. The controller has inputs for PV1 and PV2, can indicate PV and SP on LED displays, and has 1-8 setpoints. It has control outputs like PID loops, output limiter, and ramp function. Remote switch inputs and event outputs are also available as options.

Uploaded by

narkomanizca
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views2 pages

SDC40

The SDC40A is a compact digital indicating controller that accepts 4 types of inputs and can be configured using a PC. It has specifications like a memory backup, power consumption of 30VA max, and operating temperature range of 0-50°C. The controller has inputs for PV1 and PV2, can indicate PV and SP on LED displays, and has 1-8 setpoints. It has control outputs like PID loops, output limiter, and ramp function. Remote switch inputs and event outputs are also available as options.

Uploaded by

narkomanizca
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DIGITAL CONTROLLERS

SDC40A
DigitroniK
Digital Indicating Controller
The SDC40A is a compact (96×96mm) digital indicating controller that
accepts 4 types of input: thermocouple, resistance temperature detector,
DC voltage and DC current.
DIGITAL CONTROLLERS

Configuration can be done easily using a PC.

Specifications Selection Guide I II III IV V VI VII Example: C40A0D0AS000D0

General Memory backup Semiconductor nonvolatile memory Segment Model No. selection Description
Power 100 to 240Vac, 50/60Hz, 24Vdc I Basic No. C40A ↓ ↓ ↓ ↓ Digital indicating controller
Power consumption 30VA max. II Control output 0D O O – – Relay output (ON/OFF or time proportional)
Ambient temperature 0 to 50°C Voltage output (with current calibration action functions,
6D O O – –
Ambient humidity 10 to 90% RH (no condensation allowed) ON/OFF or time proportional)
Mass Approx. 750g 2G – – O O Position proportional output
PV input Type Multirange: thermocouple, RTD, DC voltage/current 5G O O – – Current output (4–20mA)
(PV1) Sampling cycle 0.1s 3D – – O O Heat-cool output, relay output + relay output
Accuracy ±0.1% FS AK – – O O Heat-cool output, relay output + current output
Bias -1000 to +1000U (U: industrial unit) 5K – – O O Heat-cool output, current output + current output
PV2 Type 4–20mA, 1–5Vdc 9K – – O O Heat-cool output, relay output + voltage output
Indication & PV, SP indication 5-digit, 7-segment LED BK – – O O Heat-cool output, current output + voltage output
setting Function indication 2-digit, 7-segment LED III Function 0 O O O O Standard model
Bar LED Motor opening, OK indication, events 4 to 8, or RSW 1 to 12 monitoring 1 O O O O Remote SP function model
No. of setpoints 1 to 8 selectable 2 O O O O Internal cascade function model
Range Selectable IV Power AS O O O O 100 to 240Vac 50/60Hz
Setpoint limit Lower: -19999 to upper limit DS O O O O 24Vdc
Upper: Lower limit to 26000 V Option 1 Standard model with additional event outputs (2 SPST
00 O – O –
Control No. of PID sets 8 (models 3D/AK/5K/9K/BK — 4 sets for cooling, 4 sets for heating) relay contacts)
output PID auto-tuning Automatic setting of PID value by limit cycle method and neural/ 01 – O – O With 4 remote switching inputs
fuzzy/smart method (no auto-tuning for 3D/AK/5K/9K/BK) 02 O – O – With 1 added SPDT relay contact event output
Output limiter (%) Lower: -10 to upper limit With 4 remote switching inputs + 1 added SPDT relay
03 – O – O
Upper: Lower limit to 110 contact event output
MV changing rate limiter 0.1 to 10.0% (every 100ms) 04 – O – O With 4 remote switching inputs + 1 auxiliary output
Control action Direct/reverse selectable 05 O – O – With 1 added event output + 1 auxiliary output
SP ramp 0 to 26000U (U: industrial unit) With 4 remote switching inputs + 1 added SPDT relay contact
06 – O – O
Unit: U/h, 0.1U/h, U/min, 0.1U/min event output + 1 auxiliary output
Remote No. of inputs 4 or 12 (option for both) 07 – O – – With 4 remote switching inputs + 2 auxiliary outputs
switch Function NOP, RUN/READY, AUTO/MANUAL, REMOTE/LOCAL, AT 08 O – – – With 1 added event output + 2 auxiliary outputs
input start/stop, direct/reverse, SP selection (PID group No. interlock), With 4 remote switching inputs + 1 added SPDT relay
09 – O – –
(RSW) Fixed MV value output, LSP shift, Analog input 2 ratio number contact event output + 2 auxiliary outputs
selection, Computer backup system 1 and 2 VI Option 2 None. (If option 1 is not designated, 0 will be selected
0 O O O O
Type Dry contact open collector transistor automatically.)
Event No. of outputs 2 (standard), or 3 to 8 (optional) With 8 added remote switching inputs + 5 added event
1 – O – O
output Type PV, dev., dev., MV, RSP, motor feedback, alarm, control outpust (open collector output)
(EV) loop diagnostics With 8 added remote switching inputs + 5 added event
2 – O – O
Control mode ON/OFF SPST relay contact outputs (open collector output) + RS-485 communications
Auxiliary No. of outputs 1 or 2 (1 for 2G/3D/AK/5K/9K/BK) With 8 added remote switching inputs + 5 added event
3 – O – O
output Type PV, SP, dev., RSP, MV, motor feedback outputs (open collector output) + RS-232C communications
(AUX) Output 4–20mAdc, load resistance: 680Ω max. VII Option 3 00 O O O O None
Communications RS-485 T0 O O O O Tropicalization
K0 O O O O Antisulfidization
D0 O O O O With test data
Accessories (sold separately) B0 O O O O Tropicalization + test data
L0 O O O O Antisulfidization + test data
Y0 O O O O With traceability certification
Part No. Description
SLP-C4AJ20 Smart Loader Package (software) • A circle (O) denotes availability.
81446083-001 Hard dustproof cover
81466087-001 Soft dustproof cover
81446084-001 Terminal cover

1-12
DIGITAL CONTROLLERS

Input Types and Ranges


Range Input Range Input Range Input Range Input
Range (°C) Range (°C) Range (°C) Range (°C)
code type code type code type code type
0 0.0 to 1200.0 10 R (PR13) 0.0 to 1600.0 20 Gold iron-chromel 0.0 to 300.0K (K: Kelvin) 48 -200.0 to +500.0
1 0.0 to 800.0 11 S (PR10) 0.0 to 1600.0 32 -200.0 to +500.0 49 -200.0 to +200.0
2 0.0 to 400.0 12 0.0 to 2300.0 33 -200.0 to +200.0 50 -100.0 to +150.0
K (CA) W (WRe5-26)
3 -200.0 to +1200.0 13 0.0 to 1400.0 34 -100.0 to +150.0 51 -50.0 to +200.0
4 -200.0 to +300.0 14 PR40-20 0.0 to 1900.0 35 -50.0 to +200.0 52 JIS '89 JPt100 -60.00 to +40.00
JIS '89 Pt100
5 -200.0 to +200.0 15 Ni-Ni·Mo 0.0 to 1300.0 36 -60.00 to +40.00 53 -40.00 to +60.00
(IEC Pt100Ω)
6 E (CRC) 0.0 to 800.0 16 N 0.0 to 1300.0 37 -40.00 to +60.00 54 0.0 to 500.0
7 J (IC) 0.0 to 800.0 17 PL II 0.0 to 1300.0 38 0.0 to 500.0 55 0.0 to 300.0
8 T (CC) -200.0 to +300.0 18 DIN U -200.0 to +400.0 39 0.0 to 300.0 56 0.00 to 100.00
9 B (PR30-6) 0.0 to 1800.0 19 DIN L -200.0 to +800.0 40 0.00 to 100.00

DIGITAL CONTROLLERS
Range Input Range Range Input Range Range Input Range Range Input Range
code type (programmable) code type (programmable) code type (programmable) code type (programmable)
64 4 to 20mA 67 -10 to +10mV 70 -1 to +1V 73 0 to 10V -19999 to +26000
65 0 to 20mA -19999 to +26000 68 0 to 100mV -19999 to +26000 71 1 to 5V -19999 to +26000
66 0 to 10mV 69 0 to 1V 72 0 to 5V
• °F display is selectable.

Dimensions (Unit: mm)

• SDC40A

• Panel cutout
Individual standard mounting Individual mounting Side-by-side mounting
or with soft dustproof cover with hard dustproof cover

1-13