Pcwin-Pck: Instruction Manual
Pcwin-Pck: Instruction Manual
Pcwin-Pck: Instruction Manual
PCwin-PCk
PROGRAMMER FOR PCk05/PCk06
INSTRUCTION MANUAL
Note:
Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation.
All other product names are trademarks of their respective owners.
Introduction
Thank you very much for purchase this product and please make sure the
following notices.
• For the safe use of this product, read thoroughly this Instruction Manual and
related manuals before operating the product. Keep this Instruction Manual
at your reach for quick reference during operation.
• Be sure to deliver this Instruction Manual to the end user of the product.
• In accordance with the provisions in the Foreign Exchange and Foreign Trade
Control Law, export of products applicable as strategic goods (or service)
requires export permit by the Japanese Government.
• In the event any defect due to our manufacture is found in our products during
the warranty period, we will repair or replace them at our discretion. We shall
not be responsible for any direct or indirect damages related to our products
except as herein stated.
Notes for Safe Use
This instruction manual contains important information on safe use of the product and preventive
Understand the following and read the text and observe the descriptions.
Explanation of indication
Contents
condensation is formed.
vibration.
2. To store the common module, make sure that the temperature will not
common module.
3. Take care that the key panel is not exposed to welding sparks or
melted solder.
module using the supplied cable, separate the cable from high
5. When the common module is not in use, remove the floppy disk
from the drive and store it in the designated case.
6. Do not turn off the power when the internal hard disk or floppy disk
is in use. The hard disk access lamp is lit when the hard disk is in
use. The floppy disk access lamp is lit when the floppy disk is in
use. Check that these lamps are not lit before turning off the
power. In particular, take special care when the internal hard disk is
in use.
(1) Do not place floppy disks in a very hot and humid place.
deformity.
head, not only causing errors but also damaging the head
mold.
(5) Do not use thinners, alcohol, Freon or the like, on floppy disks.
be deformed.
Attaching a memo pad with a clip, for example, can cause the
jacket.
If you must write on the label after it has been adhered to the
jacket, use a soft tipped pen. Writing on the jacket can leave
vertically.
Debris from the eraser may adhere to the magnetic disk and
cause errors.
T – A50 # E
E: English,N: Japanese, F : French
Cz:Checho,Ch:Chinese
Series No. Revision code
Chapter 1.Outline
Gives the outline of PCwin-PCk
Chapter 2.Installation
Explains the method of installation of PCwin-PCk
Chapter 5.File
Describes the method of operation related to files.
Chapter 10.CPU
Describes the reading and writing of data, parameters and programs with PCk05/PCk06
and about the interface between PCwin-PCk and CPU.
Chapter 11.Monitor
Describes the monitoring function and method of operation of LD/Data Register.
Chapter 12.Settings
Describes the method of changing set and current values of timer / counter as well as
set value of Register.
Chapter 13.Option
Describes about various option settings.
Chapter 14.Printing
Describes about printing function.
i
Chapter 15.Drawing Style Print
Describes about Drawing style print function.
Chapter 16.Tool
Describes about I/O Check.
ii
INDEX
INDEX..............................................................................................................................................................................iii
1 PCwin-PCk Outline...................................................................................................................................................1-1
1.1 PC2 selection reason ........................................................................................................................................1-1
1.2 PCwin-PCk limitation.........................................................................................................................................1-1
1.3 Data interchangeability......................................................................................................................................1-2
1.4 Operating Environment of PCwin-PCk.............................................................................................................1-2
1.5 Scope of PCwin-PCk.........................................................................................................................................1-3
2 Installation of PCwin-PCk.........................................................................................................................................2-1
2.1 Confirmation of version information..................................................................................................................2-4
3 Connection with CPU ...............................................................................................................................................3-1
3.1 Connection devices ...........................................................................................................................................3-1
3.1.1 PCk05 Connection.............................................................................................................................3-1
3.1.2 PCk06 Connection.............................................................................................................................3-2
3.2 Communication Setting .....................................................................................................................................3-3
iii
7.1.4 Contact Point Insertion ......................................................................................................................7-7
7.1.5 Entry of Block Comment ...................................................................................................................7-8
7.1.6 Move/ Copy of Data ...................................................................................................................................7-9
7.1.6.1 Un Do...................................................................................................................................................7-9
7.1.6.2 Re Do...................................................................................................................................................7-9
7.1.6.3 Cut........................................................................................................................................................7-9
7.1.6.4 Paste....................................................................................................................................................7-9
7.1.6.5 Copy...................................................................................................................................................7-10
7.1.7 Comment Edit(Entry/ Edit of Comment)..................................................................................................7-11
7.1.8 Sequence comments optimization ..........................................................................................................7-12
7.1.9 Display Selection......................................................................................................................................7-13
7.1.9.1 Display Number.................................................................................................................................7-13
7.1.9.2 Comment Display..............................................................................................................................7-13
7.1.9.3 Comment 100 characters display ....................................................................................................7-14
7.1.10 Change of Screen Enlargement............................................................................................................7-15
7.1.11 Change All...............................................................................................................................................7-16
7.1.11.1 Batch change of I/O Address..........................................................................................................7-16
7.1.11.2 Batch change of Application Instruction operand. .........................................................................7-19
7.1.11.3 I/O Address Batch Change (Modification File Reading) ...............................................................7-22
7.1.11.4 Batch change of Function Instruction Operands (Modification File reading) ...............................7-26
7.1.11.5 Format of Address Modification File...............................................................................................7-29
7.1.11.6 File Format Error Display................................................................................................................7-30
7.1.11.7 Cautions...........................................................................................................................................7-32
7.1.11.8 Batch interchange of AB contact Points.........................................................................................7-33
7.1.12 Re-allocation...........................................................................................................................................7-34
7.1.12.4 Re-allocation of Application Instruction Serial No..........................................................................7-34
7.1.12.5 Re-allocation of Edge Detection Address......................................................................................7-35
7.1.13 LD Block Checking.................................................................................................................................7-36
7.1.14 Search.....................................................................................................................................................7-38
7.1.14.4 Label search....................................................................................................................................7-39
7.1.15 Jump using the Book Mark....................................................................................................................7-40
7.1.16 Usage status...........................................................................................................................................7-41
7.1.17 Contact Point Table ................................................................................................................................7-44
7.1.18 Tracing Search .......................................................................................................................................7-45
8 Parameter Setting.....................................................................................................................................................8-1
8.1 CPU operation mode ......................................................................................................................................8-1
8.2 Scan Time Timer................................................................................................................................................8-2
8.3 Program Name ..................................................................................................................................................8-2
9 Program Check.........................................................................................................................................................9-1
9.1 LD Program Check............................................................................................................................................9-1
9.1.1 LD Program check result.......................................................................................................................9-1
9.1.1.1 Types of Format Error and Error Code ..............................................................................................9-2
9.1.1.2 Circuit not supported...........................................................................................................................9-3
9.2 Program size......................................................................................................................................................9-4
10 CPU .......................................................................................................................................................................10-1
10.1 Read from CPU .............................................................................................................................................10-1
10.2 Writing in CPU ...............................................................................................................................................10-3
10.2.1 All Program + Parameter .......................................................................................................................10-3
10.2.2 Program 1...............................................................................................................................................10-4
iv
10.2.3 Parameter...............................................................................................................................................10-4
10.2.4 Comment ................................................................................................................................................10-4
10.2.5 Register...................................................................................................................................................10-4
10.3 Collating with the CPU ..................................................................................................................................10-5
10.3.1 Binary checking of Program + Parameter.............................................................................................10-5
10.3.2 In case of Register .................................................................................................................................10-6
10.4 Operation Status of CPU...............................................................................................................................10-6
10.5 Stop of CPU ...................................................................................................................................................10-6
10.6 Resetting of CPU...........................................................................................................................................10-7
10.7 Error Monitor of CPU.....................................................................................................................................10-8
10.7.1 CPU error code table....................................................................................................................10-8
10.8 Setting of Data and Time in the CPU. ........................................................................................................10-11
11 Monitor...................................................................................................................................................................11-1
11.1 LD Monitor......................................................................................................................................................11-1
11.1.1 Ensued Monitoring..................................................................................................................................11-2
11.1.1.1 LD.....................................................................................................................................................11-2
11.1.2 Continuity monitor...................................................................................................................................11-3
11.2 Register and I/O Address Monitor..............................................................................................................11-4
11.2.1 Setting of monitor address .....................................................................................................................11-4
11.2.1.1 Batch setting in address..................................................................................................................11-4
11.2.1.2 Individual setting in address............................................................................................................11-5
12 Settings.............................................................................................................................................................12-1
12.1 Setting Menu..................................................................................................................................................12-1
12.2 Change of Timer/Counter current value.......................................................................................................12-1
12.3 I/O Forced on-off............................................................................................................................................12-2
12.3.1 Set the address and ON/OFF ........................................................................................................12-2
12.3.2 Writing the data to CPU .........................................................................................................................12-3
12.4 Register Edit ..................................................................................................................................................12-4
12.4.1 Register and I/O address Monitor .........................................................................................................12-4
12.4.1.1 Setting of Edit Address ...................................................................................................................12-4
12.4.1.1.1 Batch Setting of Edit Address..................................................................................................12-4
12.4.1.1.2 Individual Setting of Edit Address ...........................................................................................12-4
12.4.1.2 Offline Editing ..................................................................................................................................12-5
12.4.1.3 Data File ..........................................................................................................................................12-6
12.4.1.4 PC writing ........................................................................................................................................12-6
12.5 Register Fill ....................................................................................................................................................12-6
12.5.1 Data memory address............................................................................................................................12-7
12.6 Setting of Communication Module ...............................................................................................................12-8
12.6.1 Setting of communication conditions.....................................................................................................12-9
13 Option ....................................................................................................................................................................13-1
13.1 Customize ......................................................................................................................................................13-1
13.1.1 Font .........................................................................................................................................................13-1
13.1.1.1 Font specification ............................................................................................................................13-1
13.1.1.2 Word wrapping setting....................................................................................................................13-2
13.1.2 Color...................................................................................................................................................13-3
13.1.3 Display................................................................................................................................................13-4
13.2 Setting ............................................................................................................................................................13-5
13.2.1 File...........................................................................................................................................................13-5
13.2.2 Operation ................................................................................................................................................13-6
v
13.2.3 Short cut Key Definition..........................................................................................................................13-7
13.2.4 3 languages ............................................................................................................................................13-7
14 Print .......................................................................................................................................................................14-1
14.1 Circuit Diagram List .....................................................................................................................................14-1
14.2 Usage Status List.........................................................................................................................................14-2
14.3 Other drawing style prints ...........................................................................................................................14-2
15 Drawing Style Print................................................................................................................................................15-1
15.1 Form setup ...................................................................................................................................................15-1
15.2 Circuit Diagram List .....................................................................................................................................15-4
15.3 Usage Status List...........................................................................................................................................15-7
15.4 Other drawing style prints..............................................................................................................................15-7
vi
1 PCwin-PCk Outline
PCwin-PCk is a personal computer programming tool of the TOYOPUC PCk05/PCk06 exclusive use.
The instruction word of TOYOPUC PCk05/PCk06 cannot ..instruction word.. correct making directly because it
differs from other TOYOPUC. Therefore, the TOYOPUC PC2 instruction word is made in PCwin-PCk once, it
converts into the instruction word of PCk05/PCk06, and it writes it in CPU. The instruction word read from
PCk05/PCk06 is converted into the TOYOPUC PC2 instruction word and reading from CPU is taken into
PCwin-PCk.
PC2
PCk06
Pck05
1-1
1.3 Data interchangeability
As for PCwin-PCk, interchangeability with the data made with other tools disappears.
Pck05/PCk06
PC1 no interchangeability
PC2 no interchangeability
PC3 no interchangeability
PC10 no interchangeability
MX no interchangeability
Direct Soft no interchangeability
OS (Operating System)
PC Unit
• Display : Color display of above 1024×768 dots. (Screen Color Scheme: 16-bit color)
*1 Please acknowledge changing without a previous notice about the specification etc. for the
improvement occasionally.
*2 The following message is displayed when PCwin-PCk is executed on Windows 95/98 ME/NT,and
PCwin-PCk can’t be executed.
1-2
1.5 Scope of PCwin-PCk
TOYOPUC
PCk05
PCk06
It ..drinking.. corresponds to 2 models.
1)Please start from the setting of CPU operation mode (Details are 8. parameter setting) after the new making
procedure (Details are 5.1. new make) when you newly make the PLC data.
2)The backup data made with an old peripheral equipment cannot be used because there is no interchangeability of
data.
1-3
2 Installation of PCwin-PCk
Here method of installation of PCwin-PCk is described.
Before installing in the hard disc, turn off the anti-virus software, which becomes the cause of problem at the time of
installation.
Important
2-1
3 Entering the directory of installation destination, click <Next>.
4 For installing with default setting, click <Next> in the displayed dialog box.
With the default setting, a new folder is created without writing in the existing PCwin-PCk folder.
2-2
5. On the completion of installation, end of set up is displayed.
Press “Finish” and complete the setup.
6. To start the program, double click [PCwinPCk] from [start] – [program] – [AllwinPCk] – [PCwinPCk] or go to the
application folder by Explorer, and double click [PCwinPCk.exe] in the installed directory.
2-3
2.1 Confirmation of version information
Displayed with
or .
Option Information
Names of options installed to PCwin-PCk are displayed in the Option field of the about PCwin-PCk window.
2-4
3 Connection with CPU
In PCk05, there are two RS232C ports. Port 1 is used to connect PCwin-PCk. The baud rate of port
1 is 9600bps fixation. After writing, port 2 uses the setting data for the system parameter
register by the PCwin-PCk tool or the ladder program execution.
3-1
3.1.2 PCk06 Connection
It connects it with PCk06 with the personal computer and the cable that installs PCwin-PCk.
Please refer to connected pin explanation chart shown below when you make the cable by oneself.
The plug that suits Jack with built-in PCk06 is a plug-in phone jack of RJ12.
In PCk06, there are two RS232C ports. Port 1 is used to connect PCwin-PCk. The baud rate of port
1 is 9600bps fixation. After writing, port 2 uses the setting data for the system parameter
register by the PCwin-PCk tool or the ladder program execution.
3-2
3.2 Communication Setting
When directly connecting PCwin-PCk and CPU, carry out setting as the below
Procedure
Click the module name and name select the communication module[CPU] to be
connected.
3-3
(3)Set the communication conditions.
(5)Completion of setting
Click “OK” after all settings are complete.
3-4
4 Screen Positioning (Peripheral Devices)
Status Bar
4-1
4.1 Tool Bar
4.1.1 Standard Tool Bar
Used in Project window and Action Program Edit Window (Ladder Program Edit Window). It functions
through the click of Icon.
If unusable at the active window or selected operation, display turns gray.
Identical Function operation from the Menu is also possible based on selection from the menu bar.
<<<Funtion Name>>>
Grid Line
Zoom
Jump
Search
Re Do
Un Do
Help
Print
Paste
Copy
Cut
Save As
Open
New
Application Instruction
Counter
Timer
Reset Coil
Set Coil
Coil
Fall Differential
Rise Differential
B Contact
A Contact
Horizontal Bar
Vertical Bar
4-2
LD Program No. 1 Only.
Ladder Conversion
Jump downwards
Jump upwards
4-3
4.2 Positioning of Window
Default positioning of each window of Project, LD of PCwin-PCk is displayed with each window
overlapping as shown below.
4-4
4.3 Change of Window Positioning.
Change of positioning of each window of Project, LD can be made with “Window” menu.
All windows (Project window, LD edit window) are closed and operated. [View]-[Language] is chosen
and [Japanese] or [English] is chosen. This Command is limited to Japanese version Windows.
Then, a message is displayed. Please click [OK], and close and start PCwin-PCk. A display language
changes after starting.
4-5
5. File
In this peripheral device, basically following 4 files are handled.
*. kprj : Project file
*. kpg1 : LD (Ladder) Program+Parameter File
*. Kct3 : LD (Ladder) Comment File
*. kiod : Register Data File
These file are not specified independently but they are all selected when “*.kprj” Project file is
selected.
However, the Register Data File in selected depends on the option settings.
It is not possible preservation/to read with other tools because PCwin-PCk doesn't have the
interchangeability of other related tools and files and to do.
Moreover, the file made with other tools in PCwin-PCk cannot be read.
5-1
5.1. New
Left click the Icon of standard tool bar with mouse or on the menu bar, open new project
window by selecting (File) (New) and creation of new program will become possible.
In case file is not saved during creation, confirmation of saving is displayed.
5-2
5.2. Open (File)
Left click Icon for Standard Tool Bar with mouse or display dialog for opening file by
selecting (File) (Open) on the menu bar and file to be opened is selected. Registered file can
be changed.
File displayed here is one which iwhere the extension of Files is “*.kprj”. By specifying this
project file, all data of this project ( LD (Ladder Program, Comment Etc. ) is read.
Further, when wanting to select program created only with LD ( Ladder) Program, select *.
kpg1 from the file types.
5-3
5.3. Save
Left click the Icon of Standard Tool Bar with a mouse, or by selecting [File] [Save] on the
menu bar, ithe data is saved in the registered file after Program check.
In case of unregistered file, it has to be saved by giving it a title. (5.4 : Save As).
5.4. Save As
By selecting [File] [Save As] on the menu bar, dialog for saving by giving the data a title is
displayed.
After entering new file name, left click [Save (S)] with mouse.
When saving the file, selection of File Type (File Extension) is not required.
When the content of project is distinguished automatically at the System side.
Further, Comment data is also saved simultaneously.
5-4
5.5. Import of Related File
This function is used when copying existing data in the Project.
Once this function is executed, return to previous data can not be made.
Next as the Dialogs to specify transfer source and transfer destination will be displayed, select
the Program No. and click “OK”.
5-5
5.5.2. Import of LD Comment
Here selection of mode and that of transfer source and transfer destination is carried out.
5-6
5.6. Export of Related Files
5.6.1. Export of comment
Comment data is specified with File name and is saved.
When created with PCk05/PCk06 mode, comment format can be specified with the type of the
file.
Specify from among ” *.kct3 ” , ” *.csv ”
5-7
6 Project Window
6.1 Setting of Project Window
Settings in the Project window have been explained below.
These settings are required for drawing LD with PCwin-PCk.
Settings are possible for a maximum of 1 PLC Programs (Program 1).
Data
Setting of Parameter
Refer to method of operation of Parameter
setting
For Program 1
Refer to method of operation of LD Settings
While creating a new program, carry out setting of CPU operation mode of the parameter
in the beginning.
6-1
About Project Folder
Comment set in the system of Program name of the Parameter is displayed as Project
Folder comment.
About LD Folder
Further, ‘Ladder Sequence”, is registered as overall LD Program.
In case of LD only program, only this “Ladder sequence”, is registered.
“+” and “-” on the left side of the Folder indicate open/close state of the folder.
“+” denotes closed state of the folder. Folder can be opened by double clicking the folder
and registered contents can be displayed.
6-2
7 LD (Ladder) Window Edit
Display from Project Window.
Double clicking the “LD Folder” of Project window, open the tree.
“Ladder Sequence” are displayed. In case of LD only, “Ladder
sequence” is displayed.
7-1
7.1 PCk05/PCk06
7.1.1 Entry of New Block
When creating new circuit Block, it is necessary to carry out insertion operation of new block and create the
place for circuit, circuit creation is fully carried out with this insertion operation.
When creating new project, 3 circuit blocks of “START”, “END”, “PEND” are automatically created. In case
of main program, program is inserted between “START” and “END” and in case of sub-routine or SFC Action,
between “END” and “PEND”.
Procedure
(1) Position to be created is clicked and cursor is placed there.
Double Click
(2)On the tool bar is clicked. New Block is created and subsequent circuits are shifted.
7-2
7.1.2 Address Programming
Procedure
(1)Position to be created is clicked and cursor is placed there.
(2)Either the icon of symbol on the tool bar is clicked or the function key of the keyboard is pressed. (See
below given diagram)
(3)Symbol is positioned.
(4)If either [Enter] key is pressed or double clicked with the mouse, following input properties are displayed.
Entering [Address], [Comment]. Either press [Enter] or [Apply] button.
Memo
♦[Address] is automatically entered in capital letters even if [Capslock] is not pressed. Further, in following
cases, there is no need to enter everything.
In case of M001, enter M1
In case of M03A, enter M3A
♦ [Comment] may be entered either on the contact point side or the coil side. Entered comment is reflected
in all.
7-3
7.1.2.2 Change of Symbol
Positioned Electric Symbol is changed by the following procedure.
Procedure
(1) Either double click the symbol to be changed or place the cursor (Yellow Box) on it and press [Enter].
(2)Following Input Properties will be displayed.
M011 M11
7-4
7.1.3 Creation of OR Circuit
7.1.3.1 Line Insertion (Creation of 2nd line in the same block)
In order to create OR circuit, it is necessary to create the 2nd line in the same block.
Procedure
(1)Click the position to be created and place the cursor there.
(2)Click on the tool bar . New line will be created on line below
7-5
7.1.3.2 Drawing of OR
In order to draw the vertical bar of OR, either click the icon on the tool bar or press “F1” key.
Procedure 1
(1)Place the cursor on the position where OR is to be drawn.
Memo
♦ When wanting to delete drawn OR, place the cursor on it and click
7-6
7.1.4 Contact Point Insertion
When inserting a contact point in an existing circuit, first move the existing symbol to the right side and then
position the contact point.
Press [Insert] key to move positioned Electric symbol by 1 line to the right. Electric symbols in the cursor
position are also included. When the number than can be positioned in 1 line is exceeded, they are returned
automatically.
[Insert] key becomes invalid in case of horizontal bar before the coil, like in the above circuit.
In such a case, enter [Insert] key placing cursor on the coil. It will be automatically returned.
7-7
7.1.5 Entry of Block Comment
Comment can be inserted in each block of the circuit diagram as explanatory note. This block comment can
be displayed on the screen by putting a check against [Display] – [Block Comment]. [If not selected, there
will be no display of the comment]
Procedure
(1)By putting a check against [Display] – [Block Comment], Block comment is put in display state.
(2)Place the cursor on the 1st line of the circuit where Block Comment is to be entered and either press
[Enter] key or double click with the mouse.
The following input properties will be displayed. Here click the tab of [Block Comment].
(4)Comment up to 4 lines (50 bytes per line) can be entered. After entry of the comment, either press [Enter]
or click [Apply] button.
7-8
7.1.6 Move/ Copy of Data
7.1.6.1 Un Do
Returns the created/ edited circuit to 1 step former state. It is possible up to a maximum of 7 times.
Procedure
Either select [Edit]-[Un Do] or click or after right clicking the mouse, select “ Un Do”.
Short cut keys are [Ctrl]+[Z].
7.1.6.2 Re Do
Re does the chart returned to 1 step former position with [Edit]-[Re Do]. It is possible up to a maximum
of 7 times.
Procedure
1) Either select [Edit]-[Re Do] or click or after the right click of the mouse, select “ Re Do”.
Short cut keys are [Ctrl]+[Y].
7.1.6.3 Cut
Selected data is cut on the clipboard. Cut data can be positioned anywhere with [Paste].
Procedure
(1)In the area on the circuit, move the mouse with left button pressed and select the symbols in the
range the mouse has moved.
As for selection unit, specification with line unit where the left side area on the circuit is left clicked
with the mouse and specification with column unit where optional area on the circuit is left clicked
with the mouse is possible. Selected area is reversed displayed
(2)Either select [Edit]-[Cut] or click or after right clicking the mouse, select “Cut”.
Short cut keys are [Ctrl]+[X].
7.1.6.4 Paste
Symbols copied or cut on the clipboard are recalled and pasted.
♦In case of range specification of line unit, line is inserted. Symbol where data is copied remains there.
♦In case of range specification of column unit, overwriting is done. Symbol where data is copied
disappears.
Procedure
(1)Place the cursor in the position data is to be pasted( gray box).
(2)Either select [Edit]-[Paste] or click or after right clicking the mouse, select “Paste”.
Short cut keys are [Ctrl]+[V].
Data gets pasted. In case symbols exist in the pasted position, clip data is inserted and subsequent
data shifts downwards.
7-9
7.1.6.5 Copy
Selected data is copied on the Clipboard. Cut data can be positioned anywhere with [Paste].
♦ In case of range specification of line unit, line is inserted. Symbol where data is copied remains
there.
♦ In case of range specification of column unit, overwriting is done. Symbol where data is copied
disappears.
Procedure
(1)In the area on the circuit, move the mouse with left button pressed and select the symbols in the
range the mouse has moved.
As for selection unit, specification with line unit where the left side area on the circuit is left clicked
with the mouse and specification with column unit where optional area on the circuit is left clicked
with the mouse is possible. Selected area is reversed displayed.
(2)Either select [Edit]-[Copy] or click or after right clicking the mouse, select “Copy”.
Short cut keys are [Ctrl]+[C]. Selected symbols are copied on the clipboard.
7-10
7.1.7 Comment Edit(Entry/ Edit of Comment)
Comments of Coil etc. can be entered and edited in the exclusive List Box.
Procedure
(1)Select [Edit]- [Comment Edit]- sequence Comment] with LD Window in active state.
(2)Targeted address is double clicked with the mouse.
(3)Since dialog box of [Comment Change] is displayed, comment is entered/ corrected.
Further, input of Device name and Function Code as name of the signal is possible.
(4)Click [ OK ].
♦ Program
When there are multiple Ladder Programs, if here number is selected, that particular comment
will be displayed.
♦ Device
Comment of the Device selected here is displayed.
♦ Display Range
Select the display range of the address. However, the type of range displayed in the List box
varies depending on the device.
7-11
7.1.8 Sequence comments optimization
Sequence comments which are not used in sequence programs, I/O chart, link parameters (FL-net,
PC link, DLINK) can be deleted.
Procedure
1) Select [edit] – [comment edit] – [sequence comments optimization]. (When LD window is not active or
LD is unconverted, displays by gray.)
3) If deleted comments are saved in the files, select [collect logs] and specify the file.
7-12
7.1.9 Display Selection
7.1.9.1 Display Number
As for the number displayed on the left of LD circuit, change from step to Block number and vice versa
is possible.
Procedure
(1)Select [Display] – [Display No.] and then select [Step No.] or [Block No.].
Procedure
(1)One of the following 3 items is selected from [Display] – [[Ladder Display].
♦ No Comment
Without the display of comment, only Ladder Diagram is displayed.
7-13
♦ With Comment – Type 2
Comment is displayed only to the right or on the contact point of coil or Function Instruction. As a
result, there is lot of space between lines.
On clicking on the tool bar, comment in the cursor position in the comment box equivalent to a
maximum of 100 characters will be displayed. Comment box can be moved to an optional position.
Moreover, display/non-display state is held at the time of PCwin-PCk termination. A blank character is
displayed by "_".
Alternatively, display cursor position on window status bar, maximum 100 characters.
7-14
7.1.10 Change of Screen Enlargement
For changing the enlargement of circuit diagram, change the [size] of characters with [change] button in
[option] –[customize].
(In case of PCwin-PCk, overall size is enlarged or reduced according to character size)
Procedure
(1)Click [option] – [customize]
(2)As the Dialog box of [Customize] will be displayed, click [change] button of the Ladder in[Font] tab.
(3)As the Dialog box of [Font specification] will be displayed, select [size] appropriately and click [OK].
(4)As the Dialog box of [Customize] will be displayed again, click [OK] if the contents of change are
fine.
<Details Item>
Customizing of Font
7-15
7.1.11 Change All
V × ○ × × × × × ×
T × × ○ ○ × × × ×
C × × ○ ○ × × × ×
L × × × × ○ ○ ○ ○
X × × × × ○ ○ ○ ○
Y × × × × ○ ○ ○ ○
M × × × × ○ ○ ○ ○
•Procedure for carrying out batch change for the Program as a whole during display.
7-16
(2)Click [Add] button.
7-17
•Procedure for batch change of specified range.
(1)Data range that is to change as a batch is selected.
For selection, move the cursor to near the Step No. and while pressing the left button, move to the
last line of the object range. Highlighted portion will be the selected range.
7-18
7.1.11.2 Batch change of Application Instruction operand.
Operands of Application Instruction can be changed all together.
Note: It is unable to alter the types of the addresses of before change as well as the addresses of after
change.
The result of change and the input example of change using function operand could be displayed by
selecting [Help] button.
7-19
•Procedure for Batch change during displayed Program.
(1)Click [Edit] – [Change All] – [Application Instruction Operand].
7-20
(4)Click [OK]. Set Device will be displayed in the change list.
7-21
7.1.11.3 I/O Address Batch Change (Modification File Reading)
Addresses of coil and each contact point can be changed altogether by reading the Address
Modification File and by dividing them into multiple address areas.
It may be noted that combinations of modifiable addresses have certain limitations.
Below a list of combinations of Basic Addresses and Extended Addresses is given.
V × ○ × × × × × ×
T × × ○ ○ × × × ×
C × × ○ ○ × × × ×
L × × × × ○ ○ ○ ○
X × × × × ○ ○ ○ ○
Y × × × × ○ ○ ○ ○
M × × × × ○ ○ ○ ○
7-22
•Procedure for carrying out Batch Change in the whole Program being displayed.
(Note) When there are multiple programs in PC3 Mode, only the program being displayed canbe
targeted.
7-23
Instance of Address Modification File (*.csv)
#CHANGEALL
#BEGIN_IOBIT File Header [Must]
Y100 Y700 I/O Address Batch Modification Start Mark [Must]
Y101 Y701
Y102 Y702
P1-L200 X300 Pre-modification Address, Post-modification Address
P1-L201 X301
P1-L202 X302
P1-D00FF-F P1-M000
EM000F P1-D00FF-0 I/O Address Batch Modification End Mark [Must]
#END
#BEGIN_FUNCOP
:
(Function Instruction Operand Change All Indication)
:
:
#END
(3) Confirm the read modified address and if it is fine, click [Execute] button to modify it.
7-24
Following message will be displayed on completion of modification.
7-25
7.1.11.4 Batch change of Function Instruction Operands (Modification File reading)
Function Instruction Operands can be changed altogether.
• Procedure for carrying out batch change in the Program being displayed.
7-26
Instance of Address Modification File (*.csv) Format
(3) Confirm the read address and if it is fine, modify it by clicking [Execute] button.
7-27
•Procedure for Batch change of specified range.
(1)Select the data range that needs to be batch changed.
Move the cursor near the Step No. and while pressing the left button, move to the last line of the
object range. Highlighted portion will be the selected range.
7-28
7.1.11.5 Format of Address Modification File
(1) Mention the keyword for Address modification :#CHANGEALL at the top of the file.
(2) Modification data of I/O address is mentioned in-between the start mark:#BEGIN_IOBIT and
the end mark :#END.
(3) Address modification data of Function Operands is mentioned in between the start
mark :#BEGIN_FUNCOP and the end mark :#END.
(4)Modification data of I/O Address and Address Modification Data for Function Operands are indicated
in the order of pre-modification address, post-modification address and comment.
pre-modification address,
#CHANGEALL post-modification address and comment
#BEGIN_IOBIT Y10, Y20, COMMENT1
Y11, Y21,
:
I/O Address Modification Data
:
#END
#END
7-29
7.1.11.6 File Format Error Display
In case there is any error in the format at the time of reading the Address Modification File, following
message will be displayed. Re-execute after modifying the data in accordance with the format.
1) When address specification other than Bit Address exists in the modification data of I/O Address.
ex.L000W in the 3rd line of CSV file.
2) When Bit Address specification that cannot be used in the modification data of I/O Address exists.
ex.L000-0 in the 3rd line of CSV file.
7-30
5) There are unnecessary address specifications.
ex.R0000-0 in the 3rd line of CSV file.
6) There is no start mark :#BEGIN_FUNCOP in the Address Modification data of Function Operand.
ex.Detection of #END without the start mark in the 41st line of CSV file.
8) There are unnecessary address specifications in the Address modification data of Function Operand.
ex.R0000 in the 6th line of CSV file.
7-31
7.1.11.7 Cautions
• When specifying bytes for the pre and post modification address, make it as L -> L, H -> H. It cannot
be L -> H,H -> L .
• Address once modified cannot be modified again.
• Pre-modification address cannot be repeated.
Pre-modification address,
post-modification address
* I/O Address(X/Y) is described with Y.
Y10, Y20 • • • 1)
* P1-MΔΔΔ M etc. are described indicating the Program
P1-M1, P1-M2 • • • 2)
number.
: • • • 3)
When Address Conversion(A↔B) occurs in the Address Modification File, it is described as A→B ,B→
A.
Comment 1 Comment2
X10 X11
|------||------------||-----------
Pre-modification address,post-modification address
Y10, Y11
Y11, Y10
Comment 2 Comment 1
X10 ↔ X11 Address Conversion
X11 X10
|-------||------------||-----------
Comment 1 Comment 2
X10 X11
|-------||------------||-----------
Pre-modification address, post-modification address
Y10, Y11
Y11, Y12
Comment 1 Comment 2
X11 X12
|------||------------||-----------
7-32
7.1.11.8 Batch interchange of AB contact Points.
Batch interchange of A contact point and B contact point of specified address is possible.
When Symbolic Programming is ON, this function cannot be used.
Procedure
(1)Click [Edit] – [Batch Change] – [Interchange of AB Contact Points].
7-33
7.1.12 Re-allocation
7.1.12.1 Re-allocation of Application Instruction Serial No.
When CPU reading and the file is written because the function to memorize the serial number in
PCk05/PCk06 is not provided, the application instruction serial number is renewed by the automatic
operation in PCwin-PCk.
Serial No. allotted to the Application Instruction is re-allocated in order from the start of the data.
Before Change
After Change
Serial No. (F001-) is related to Comment File (can be edited with Device F of Comment Edit) but since
this command simultaneously changes them also, their relation with the comment file is not disturbed.
7-34
7.1.12.2 Re-allocation of Edge Detection Address
When CPU reading and the file is written because the function to memorize address (P -) in PCk05/PCk06 is not
provided, the edge detection address renewal is done by the automatic operation in PCwin-PCk.
Address P cannot be used by the coil, AND, and the OR point of contact in PCk05/PCk06.
Addresses (P -) of Rise Differential (PTS) and Fall Differential (NTS) will be allocated from the start of
the data.
Before change
After change
7-35
7.1.13 LD Block Checking
2 Data files are compared and blocks that are different or blocks only on one side will be displayed.
Rename the program prior to change and by comparing the program with that after change, corrections
can be easily grasped. Comparison is made between currently displayed program and the program
having similar number as the selected file.
Procedure
(1)Display the LD Program to be compared.
(2)Click [Edit] – [Block checking]
(3)Following dialog for File selection will be displayed.
Select the LD Program file which is the object of comparison.
7-36
(5)Following comparison, [S] will be displayed if they are same, [D] if different and [N] if blocks exist
only on one side. Displayed numeral implies the serial number of the block.
[Comparison] button
Comparison of 2 Data Files is executed.
7-37
7.1.14 Search
Contents of Circuit Data of currently displayed Program can be searched by specifying the character
sequence.
Procedure
(1)Click [Display] – [Search] and next menu will be displayed.
(2)Depending on the item to be searched, click the tab of one of the following [Coil/Contact], [Function],
[Comment].
(3)Check the check box of the type that is the object of search from the [Search Object].
(4)After feeding characters in [Address] (or [Character Sequence]), execute search with
[Search downwards] or [Search upwards].
7-38
7.1.14.1 Label search
In the address programming, label search can be searched by using LD search dialog.
(In a symbolic programming, it correspond by the tag name search. )
It searches character string in the address column of LD search dialog.Then display jump to the
corresponding position.This character string is included in the object of the search as a label..This
character string is included in the object of the search as a label.
The comment character string which contains the specified character string is searched.
Example) Specified character string:AA
Tag name or Comment string Agreement
AA O
AABB O
BAA O
BAAC O
BADAC X
'Search '****' is not found' is displayed when there is no correspondence in the result of the search.
**** : The character string for search.
•Label
7-39
7.1.15 Jump using the Book Mark
By setting bookmark in each point of the circuit diagram, display can be made by instantaneous jump.
(2)Click the Icon button. Marks like shown below will be affixed.
When jumping downwards than the present cursor position, click the button and
Click button.
7-40
7.1.16 Usage status
Usage Status List for addresses are displayed by choosing [View]-[Used Status] in menu bar.
Both addresses used in coil·contact and in function operand are displayed with mark IN USE. Non-used
addresses are displayed with mark "·".
Input area and output area are displayed with background colors of light blue and orange respectively.
Mark Explanation
. Non-use Address
lower case A Contact, B Contact, Edge and Function input operand
upper case Coil and Function output operand
Background color Light blue Function input area
Background color Orange Function output area
(Example) M
m : Using in contact
M : Using in coil
Light Blue : Function input area
Orange : Function output area
[Configure] button
Display for Usage Status can be changed
Configure is changed along with touching button [OK]. To apply the change, please re-open the
Usage Status.
7-41
It explains the method of the display with the following circuits.
2
Only the coil
Display of 1, 2, 3
Only the contact : lower case[m]
Only the coil : upper case[M]
Contact and coil : upper case[M]
DWORD instruction :
Display of 6 All the DWORD areas are displayed.
Display of 7
7-42
The function which corresponds to the input/output area display is as follows.
Function Direction kind FUN No.
4-digit hexadecimal constant move WMOV FUN101
8-digit hexadecimal constant move DMOV FUN102
4-digit hexadecimal constant 2-location move WMOVT FUN110
2-byte direct move WMOVE FUN0
Move
4-byte direct move DMOVE FUN111
instructions
Word data block move WBMOV FUN119
Byte data block exchange BXCH FUN134
Word data block exchange WBXCH FUN135
Word data fill WFIL FUN129
7-43
7.1.17 Contact Point Table
Jump using Contact Point Table can be made.
Place the cursor on the Contact Point or coil to be searched, and by selecting [Display] –[Contact Point
Table], the contact point table is displayed.
Here, if the position where the jump is to be made is double clicked, jump can be made.
Further, with the contact point table being displayed, if [search] is clicked, contact Point Table of that
address will be displayed.
It can be used during editing and monitoring. However, during monitoring, cursor is not displayed.
7-44
7.1.18 Tracing Search
Jump to the coil is made with the right click of Contact. Further, with the right click of the coil, return to
the original contact position is made. Tracing search up to a maximum of 16 steps is possible.
During tracing search, jump into self program or to other program is possible.
However, if selection of Circuit Edit-Program is made, this function is reset.
7-45
8 Parameter Setting
For parameter setting, if the Folder of parameter on the Project Screen is double clicked, following
parameter setting items will be displayed.
Next by double clicking the items to be set, setting dialog will be displayed.
Double-click the
item to be set
8-1
8.2 Scan Time Timer
Scan Time Value of overall Program of the System, Scan Time value of Main Program are set. At the
time of Program execution, if set scan time is executed, CPU error will occur.
Program name can be respectively set in the system. Input Range is maximum 8 half size
characters.
Program Name set here will be displayed in the Program Folder of the Project Screen.
8-2
9 Program Check
After creating the program, carry out Program Check for verification.
Setting by which Duplication Check targets output address of Function instruction by setting option.
[Option] – [Set] – [Operate]
9-1
9.1.1.1 Types of Format Error and Error Code
(1) Format Error
Error Code Details
04 Address other than "P" was used in PTS or NTS Instruction.
05 Address "P" has been used twice.
0C Undefined Instruction is included in the Program.
When above errors occur, modification can be carried out with the Ladder symbol.
**
9-2
9.1.1.2 Circuit not supported
Example of
equivalent
circuit
9-3
9.2 Program size
Displays rate of program Capacity, Free space, and Raito of free space for every Program.
9-4
10 CPU
By connecting with CPU, reading and writing of Program comment Register Data and Setting of monitor
data can be carried out.
Further, in case Program on PCwin-PCk side is edited and the File is not saved, following message is
displayed.
During reading, following dialog is displayed and it implies that it is being read.
10-1
Program check is automatically carried out on completion of reading.
In case any error is detected during Program Check, details of error are displayed.
In case there is no error, check results are not displayed.
10-2
10.2 Writing in CPU
The following writing selection operation is necessary when the project names (Only ASCII 8 characters) in
CPU are compared at the time of writing and it doesn't agree.
The project names of CPU are only ASCII 8 characters.
When Program contents and the type of CPU do not match, following message is displayed and writing is
terminated.
10-3
Moreover, following Massage is displayed for the RUN mode.
10.2.2 Program 1
Data of Program 1 only is written.
10.2.3 Parameter
Writes Parameter information.
Use it when only Parameter has been changed.
Carry it out in the RUN stopped state of CPU.
10.2.4 Comment
Writes Comment Data.
It can not be written in CPU of PCk05/PCk06.
10.2.5 Register
Writes Register Data.
Since following Register selection screen will be displayed, write after selecting the register where writing is
To be executed.
10-4
10.3 Collating with the CPU
10.3.1 Binary checking of Program + Parameter
Program and Parameter information of tools and CPU is checked at the binary level.
10-5
10.3.2 In case of Register
Register data of tool and CPU is checked.
PCw in
Processing is cancelled if [No {N}] is selected. In such a case, following message is displayed.
10-6
If [Yes {Y}] is selected, CPU stop state is released. In such a case, following message is displayed.
10-7
10.7 Error Monitor of CPU
Error information up to 16 times in the past is memorized in CPU. The information can be read to
PCwin-PCk.
Note) Only PCk06 is good at the error monitor. PCk05 is not good at the error monitor.
Please monitor the error code of special register S01D, S01E, and S01F by 11.2
registers and the I/O address monitors and refer to the error code for PCk05.
The detailed display function is not provided. A detailed button becomes a gray display.
10-8
Error code PCk05 PCk06 Description
E200
○ The I/O module broke down.
I/O MODULE FAILURE
10-9
Error code PCk05 PCk06 Description
10-10
10.8 Setting of Data and Time in the CPU.
Reading from PC
Date and Time are read in PC win from the PC built in clock.
In this case, first 2 digits of the western calendar are read from the internal clock.
10-11
11 Monitor
11.1 LD Monitor
If [Monitor] – [Monitor Start] are selected with LD window in the displayed state, LD monitor
will start.
Monitor displays the current value of Timer/ Counter, Contact / Coil state and the contents of
data memory specified with Operand of Application Instruction,
The monitor result of the function operand could be changed to Hex, Dec or Oct via the choice
in menu Select - [Set] - [Operate] - [Type of Register Contents].
11-1
11.1.1 Ensued Monitoring
11.1.1.1 LD
By double clicking contact point at the time of monitoring LD, jump to that coil can be made.
Moreover, by double clicking the left of the coil, return to the original contact position is made.
Tracing up to a maximum of 16 steps can be made.
Double-click
11-2
11.1.2 Continuity monitor
The continuity monitor display monitor can be set by "Change to continuity monitor display" of
[Option]-[Configuration]-[Operation]of the menu. Contact/Coil/Bar/NOT is expressed by the
display color.
Notes
•Edge (PTS,NTS) /function cannot continuity monitor display.
•The display with the ladder window might not be able to continuity monitor display in case of
Block on the way.
11-3
11.2 Register and I/O Address Monitor
[Register – I/O Address Monitor] is selected on the Monitor Menu.
This screen is used combined with monitor.
11-4
11.2.1.2 Individual setting in address
(1) Add
When selecting [Addition of address], Address Input Screen will be displayed.
(2) Change
Place the cursor on the address to be changed and when [Change] is selected, Address
Input Screen will be displayed.
(3) Erase
Place the cursor on the address to be erased and click [Erase]. Address will be erased.
(4) Clear
If [Clear] is clicked, following message will be displayed.
(5) Read
A click of [Read] displays the address saved by [Save].
(6) Save
A click of [Save] saves the address displayed now.
11-5
12 Settings
12-1
12.3 I/O Forced on-off
It is possible that the bit address in 16 points or less is turned on or off at the same time.
The following dialog is displayed.
Add the bit address turned on and off with [addition] button.
If you click [PC writing]button, the data is written.
If you click [Keeping relay display]button, the list of keeping relay is displayed.
If the keeping relay is selected, it is set in the [Address]item with [OK]button.
12-2
12.3.2 Writing the data to CPU
If you click [PC writing]button, the following message is displayed.
However, in case PC is under RUN, since operation results of sequence program are given preference,
execution result sometimes becomes OFF even if ON is set.
Note) I/O Forced ON-OFF does not have Hold function. Consequently, when I/O Forced ON-OFF is
carried out during RUN, I/O state changes in accordance with sequence operation or Refresh
result.
12-3
12.4 Register Edit
This screen can be used along with monitoring. If [Monitor Start] is clicked, monitoring will start.
12-4
(2)Change of Address
Place the cursor on the address to be changed and if [Address Change] is selected, Address
Input screen will be displayed.
0107
(3)Deletion of Address
Place the cursor on the address to be deleted and if [Address Delete] is clicked, address will be
deleted.
(4)Clear Address
If [Clear Address]is clicked, following message will be displayed.
(5)Read Address
If [Read Address] is clicked, addresses to be edited and saved in [Save Address]will be
displayed.
(6)Save Address
If [Save Address]is clicked, currently displayed edited addresses will be saved in the internal data
of Pcwin.
After selecting the type of data(hexadecimal, decimal, octal)enter the set value and click [OK].
This state is offline editing state (change of data inside the PCwin) register data and writing in
CPU is not made.
12-5
12.4.1.3 Data File
If [Data File]is clicked, Set Value Edit Screen will be displayed. After entering the set value, click[OK]. All the
data of edited addresses will be changed to set value.
This state is one of offline editing(change of data inside Pcwin) of register data and it is not written in the
CPU.
12.4.1.4 PC writing
When there is need to write in the CPU, click [PC writing] . All the data displayed on the screen will be written
in the CPU.
Since above screen will be displayed, operate in accordance with the message. Following message will be
displayed at the time of [writing].
12-6
12.5.1 Data memory address
D0000
3200
∼0C7F
D0000
12 D Data register - 3200 - O
∼0C7F D1000
4096
∼1FFF
S0080
64
∼00BF
S0000
16 S Special register - 128 - O
∼007F
S00C0
64
∼00FF
S0100
768
∼03FF
12-7
12.6 Setting of Communication Module
This function sets the connection method of CPU and PCwin-PCk and it is not the writing function for set
data in the CPU.
Use it when connection method with CPU is changed.
Procedure
(1)Click [Setting]--[Setting of communication module]
The name list which has already been set is displayed. Select the name and click [Delete]button,
[Change]button or [Addition]button.
When selecting “ME-NET, HPC Link”, “Ethernet[Link]”, “CPU[Link]” ”In case of CPU – USB[Link] ”,always
12-8
set [via link].
(5)End of Setting
Click [OK] when all settings are complete.
12-9
13 Option
13.1 Customize
13.1.1 Font
Display font and size of characters can be changed for each SFC and Ladder.
On clicking [Change], since dialog for font specification will be displayed, change appropriately.
13-1
13.1.1.2 Word wrapping setting
Word wrapping function is meant for preventing the loop back in the middle of character string at
the time of line feed.
Setting for display/ no display of word wrapping should be executed for SFC comment, ladder
coil comment, and ladder contact comment respectively. This setting is valid during printing also.
No word wrapping Word wrapping done
SFC comment
Ladder contact
comment
13-2
13.1.2 Color
On clicking Foreground and Background, dialog for color setting will be displayed.
13-3
13.1.3 Display
13-4
13.2 Setting
13.2.1 File
• I/O Register
When reading and saving the Program, one can set simultaneous reading and saving of I/O Register Data
File. (File Extender : *.rr1, *.rr2)
13-5
13.2.2 Operation
13-6
13.2.3 Short cut Key Definition
13.2.4 3 languages
13-7
14 Print
Only LD Program, displayed currently along with LD are target of printing.
After displaying LD Program to be printed, select the Print Menu.
14-1
14.2 Usage Status List
Address Usage Status in use can be printed with [DIFFERENCE OF PROGRAM] or [DIFFERENCE
OF DEVICE].
• Cover
Cover is printed along with print start as setting check ON.
14-2
15 Drawing Style Print
Printing of the drawing style can output the printing list with a drawing frame of the CAD
drawing style. [File]-[Drawing Style Print] A printing list is chosen. This function is unless the
option 2 (Drawing Style Print:TJA-6042/6045) is installed, it cannot be chosen.
It becomes a project
name at the time of
un-inputting.
15-1
(1) The printing position in the cover of each item
A MAKER
B MACHINE NO.
O C MACHINE NAME
D DRAWING NO.
E DESIGN CHANGENO.
F START NO.
G STD.DRAWING NO.
H DEVICE CODE
I CONTENTS
J PROGRAM NO.
K DRAWING FOR
L MESSRS
M USER’S NO.
N REMARKS
REMARKS1(COPY
O
RIGHTS)
P PROGRAM NAME
Q UPDATE
R PEGE NO.
B C L M K
A D E
15-2
(2) Position where circuit chart list of formatting item is printed
A MAKER
B MACHINE NO.
C MACHINE NAME
D DRAWING NO.
E DESIGN CHANGENO.
F START NO.
G STD.DRAWING NO.
O H DEVICE CODE
I CONTENTS
J PROGRAM NO.
K DRAWING FOR
L MESSRS
M USER’S NO.
N REMARKS
REMARKS1(COPY
O
RIGHTS)
P PROGRAM NAME
Q UPDATE
R PAGE NO.
J H
G Q P M I D A E R
15-3
15.2 Circuit Diagram List
LD Program is printed.
Select [File] – [Drawing Style Print] – [Circuit Diagram List] on the menu bar and display the
circuit diagram list dialog.
The device which prints "Contact Table List Page" of "Circuit Diagram List" is decided by setting this dialog. After
"Contact Table List" is printed, the print of "Contact Table List Page" of "Circuit Diagram List" can be printed.
15-4
(1) About "Contact Table List Page" of "Circuit Diagram List"
The following procedure performs printing of "Contact Table List Page."
1. Print "Contact Table List" after specifying a device by front page "Contact Table List
Dialog."
2. Print "Contact List Page" after a check by " Circuit Diagram List Dialog."
The device which prints "Contact Table List Page" to "Circuit Diagram List" is a device
specified by "Contact Table List Dialog."
Contact Table
102
Page
Circuit Diagram
15-5
(2) Explanation of coil cross reference
When the "coil reference" of a circuit diagram list dialog is checked, it outputs in this form.
All become blank when there is no check in "Coil reference".
15-6
15.3 Usage Status List
Address Usage Status in use can be printed with [DIFFERENCE OF PROGRAM] or
[DIFFERENCE OF DEVICE].
• Cover
Cover is printed along with print start as setting check ON.
15-7
16. Tool
Tool has following functions
• I/O check (for input/output)
When executing, entering password “#OUT” ( #OUT:OK / #out:NG ), after push [continue] button.
I/O Button
Max. 16 Nos.
(Caution) Forced output of input cannot be carried out in the I/O check function.
16-1
16.1.1. I/O Button Setting
On clicking [I/O] button of I/O check, I/O button set screen is displayed.
[Set Type] 16 Point bundle Setting : 0~15 bit of the specified address from top are set.
Individual Setting : Only 1 point is set.
Default Only in case of top-most level button of [Set] button is “16 point bundle setting”.
Default beyond the second line is “Individual Setting”.
[Monitor only] Displays the state of address, (Setting of Initial value/End value cannot be carried out)
[Address] ON/OFF address is entered.
[Comment] Comment of the specified address is displayed.
It can be edited but edited comment is valid only in I/O check function.
[Initial Value] Sets ON/OFF at the time of execution start.
[End Value] Sets ON/OFF at the time of execution stop.
Setting NONE becomes the state when execution is stopped.
Click, Status
Change
Yellow
Gray
Execution-in-progress state
Execution Stop State
Yellow Gray
Click
16-2
17. Switch among 3 comment languages
17.1. Summary
Only the program can write CPU in PCk05/PCk06. The comment cannot write CPU.
Three comment languages can shown/edited/switched/printed only in the personal computer file.
PCwin
Japanese
English
Chinese
Printt
Japanese
English
Chinese
17-1
Files using three comment languages (Project example : TOYODA)
Main projects
TOYODA.CSV Comment files
The first
language TOYODA$***.DFS Format set files *1
TOYODA$***.COV Cover set files *1
The TOYODA$C2.CSV Comment files
second TOYODA$***.DFS Format set files *1
language TOYODA$***.COV Cover set files *1
TOYODA$C3.CSV Comment files
The third
language TOYODA$***.DFS Format set files *1
TOYODA$***.COV Cover set files *1
*1 It is done when [Cover data and format data open/save at the same time] is set to be ON.
[Cover data and format data open/save at the same time] appear after clicking
[Option]-[Configuration]-[File].
*** To be determined according to various languages (JPN: Japanese,ENG: English,CHN:
Chinese,CZE: Czech,FRA: French)
When showing various language comments, the corresponding font needs to be inputted in
advance. Regarding to the font input, please refer to the Windows manual.
The language for the following comment display is fixed (the three comment languages can not
be replaced).
But various functions can be normally operated.
17-2
17.2. Initial settings
The explanation on the initial settings of three comment languages switch.
17.2.1. Font settings
Only when changing fonts, can the following operation be conducted.
(1) Select [Option]-[Customize]
(2) After selecting the language to change font, press [Change] button.
(3) After changing to the font of designated language, press [OK] button.
(4) After confirming the settings in the customized window, press [OK] button.
17-3
17.2.2. Function of setting 3 comment languages
(2) The language settings when building new projects. Please select the language for new projects
from the five languages.
17-4
17.4. Drawing style print method
To print in designated language can be realized.
(The characters and comment characters in the drawing frame can be printed in the designated
language.)
(1) Select printing language based on the sequence in [17.3. Switching method of comment display]
(2) Select [File]-[Drawing Style Print]-[Format Setup]
*Since the next time, while opening the project, the format set data can also be read in.
*The format set files can not be written in CPU.
17-5
17.5. Regular printing method
The characters of the cover set and comment characters can be printed in the designated language
For the operation method, please refer [17.4 Drawing style print method]
Based on the login at the language selection window, determine whether to produce the cover set
data file of various languages
*Since the next time to open the project, data can also be read in simultaneously.
*The cover set files can not be written in CPU.
(2) The first language is changed to [Chinese], and the third language is changed to [Japanese].
(3) Press [Registration] button, then replacement is completed.
17-6
• The content of this manual may be changed without prior notice.
• We will very much appreciate your notifying us should you find any questions,
mistakes, or omissions in this manual.