Sika Bitumen 60
Sika Bitumen 60
Sika Bitumen 60
3. Test Certificates
Sika®-Bitumen
Bitumen Emulsion Damp-proofing & Protective Coating
®
Product Description Sika Bitumen -60 is a brown-black bitumen liquid emulsion with excellent adhesion,
which dries to a tough, seamless, Damp-proofing and protective coating for concrete
structures and steel elements.
Suitable for tropical and hot climatic conditions.
®
Uses Sika Bitumen-60 is used for:
Tanking and Damp-proofing of substructures to provide an impervious
membrane in wet areas.
Damp proof membrane for roofs
Floor slabs
Basements, Retaining walls
Landscape decks
Curing membrane
®
Advantages Sika Bitumen-60 provides
Excellent adhesion to moist building substrates
Efficient curing membrane to freshly laid concrete
Single component
Water based , non-toxic
Economical , easy to apply, reduces labour costs
Can be applied on vertical and horizontal surface.
Impermeable to water
Seamless, joint free
Unaffected by high ambient temperature
High resistance to aggressive soils and Sulphate contaminated ground water
Low odour, dries without generating strong vapours
Product Data
Form Liquid
Appearance/ Colours Dark Brownish to Black (when dry)
Packaging 20 lt and 200 lt drums
Storage
Storage Conditions Store in original sealed containers under shade in a cool and dry environment at
temperatures between 5°C and 35°C.
Shelf Life 12 months minimum from production date when stored properly in original
unopened containers.
Technical Data
Chemical Base Bitumen Emulsion
°
Density (at 23 C) ~ 1.00 kg/lt
Flash Point Non-Flammable
Application Details
Substrate preparation All surfaces must be sound, even, free from dust, loose particles and any
contamination.
®
Sika Bitumen-60 may be applied to damp but not waterlogged surfaces.
®
Hot and very dry, porous concrete surfaces must be primed by diluting Sika
Bitumen-60 with clean water at 1:1 ratio (by weight).
Application The drums must be stirred well before use.
Where a single drum is used for prolonged periods, occasional stirring during
application is recommended.
If a primer coat is applied, allow it to dry completely before applying subsequent
coats.
®
Apply Sika Bitumen-60 evenly and in one direction using a stiff brush.
A two-coat application is recommended to avoid possible gaps in the film.
Each coat must be allowed to dry before applying the next one.
In wet areas, where a key to subsequent layers (e.g. screed, tile bedding, etc.) is
required, blind the fresh top layer with clean sharp sand.
®
Do not apply Sika Bitumen-60 to outside areas in wet weather or when rain is
expected.
Cleaning Clean all equipment and tools with water immediately after use.
Health and Safety For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
Information physical, ecological, toxicological and other safety-related data
The information, and, in particular, the recommendations relating to the application
Legal Notes and end-use of Sika products, are given in good faith based on Sika's current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sika’s recommendations. In
practice, the differences in materials, substrates and actual site conditions are such
that no warranty in respect of merchantability or of fitness for a particular purpose,
nor any liability arising out of any legal relationship whatsoever, can be inferred
either from this information, or from any written recommendations, or from any other
advice offered. The user of the product must test the product’s suitability for the
intended application and purpose. Sika reserves the right to change the properties
of its products. The proprietary rights of third parties must be observed. All orders
are accepted subject to our current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.
All products are manufactured under a management system certified to conform to the requirements of the quality,
environmental and occupational health & safety standards ISO 9001, ISO 14001 and OHSAS 18001.
Sika UAE LLC Sika Gulf B.S.C Sika Saudi Arabia Co. Ltd
P.O. Box 126212 Building 925, Road 115 Obaikan Building
Dubai Sitra Area 601 Al-Zahra
United Arab Emirates Adliya, Kingdom of Bahrain Jeddah 23522-4522
Phone: +971 4 4398200 Phone: +973 17738 188 Saudi Arabia
Fax: +971 4 4393606 Fax: +973 17732 476 Phone: +966 2 692 7079
[email protected] [email protected] Fax: +966 2 692 1272
www.sika.ae www.sika.com.bh www.sika.com.sa
Sika® Bitumen-60
1.2 Relevant identified uses of the substance or mixture and uses advised against
Product use : Bituminous coating
1.3 Details of the supplier of the safety data sheet
Company name of supplier : Sika Saudi Arabia Co. Ltd
Salama Bldg, First Floor
Prince Sultan Street
Al-Salamah - P.O Box 112356
21371 Jeddah
Saudi Arabia
Telephone : +966 12 692 7079
Telefax : +966 12 692 1272
E-mail address of person : [email protected]
responsible for the SDS
1.4 Emergency telephone number
-
3.2 Mixtures
Hazardous components
Remarks : No hazardous ingredients
Sika® Bitumen-60
In case of skin contact : Take off contaminated clothing and shoes immediately.
Wash off with soap and plenty of water.
4.2 Most important symptoms and effects, both acute and delayed
Symptoms : See Section 11 for more detailed information on health effects
and symptoms.
4.3 Indication of any immediate medical attention and special treatment needed
Treatment : Treat symptomatically.
Sika® Bitumen-60
Hygiene measures : When using do not eat or drink. When using do not smoke.
7.2 Conditions for safe storage, including any incompatibilities
Requirements for storage : Keep container tightly closed in a dry and well-ventilated
areas and containers place. Store in accordance with local regulations.
Sika® Bitumen-60
Skin and body protection : Protective clothing (e.g. Safety shoes acc. to EN ISO 20345,
long-sleeved working clothing, long trousers). Rubber aprons
and protective boots are additionaly recommended for mixing
and stirring work.
Odour : characteristic
pH : Not applicable
Density : 1 g/cm3
at 25 °C
Sika® Bitumen-60
10.1 Reactivity
No dangerous reaction known under conditions of normal use.
10.2 Chemical stability
The product is chemically stable.
10.3 Possibility of hazardous reactions
Hazardous reactions : No hazards to be specially mentioned.
Acute toxicity
Not classified based on available information.
Skin corrosion/irritation
Not classified based on available information.
Serious eye damage/eye irritation
Not classified based on available information.
Respiratory or skin sensitisation
Skin sensitisation: Not classified based on available information.
Country SA 000000612279 5/9
SAFETY DATA SHEET
Sika® Bitumen-60
12.1 Toxicity
No data available
12.2 Persistence and degradability
No data available
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
Product:
Assessment : This substance/mixture contains no components considered
to be either persistent, bioaccumulative and toxic (PBT), or
very persistent and very bioaccumulative (vPvB) at levels of
0.1% or higher.
Product:
Additional ecological infor- : There is no data available for this product.
mation
Sika® Bitumen-60
14.1 UN number
15.1 Safety, health and environmental regulations/legislation specific for the substance or mix-
ture
REACH - Restrictions on the manufacture, placing on : Not applicable
the market and use of certain dangerous substances,
preparations and articles (Annex XVII)
Sika® Bitumen-60
Seveso III: Directive 2012/18/EU of the European Parliament and of the Council on the control of
major-accident hazards involving dangerous substances.
Not applicable
Volatile organic compounds : Law on the incentive tax for volatile organic compounds
(VOCV)
no VOC duties
The information contained in this Safety Data Sheet corresponds to our level of knowledge at the
time of publication. All warranties are excluded. Our most current General Sales Conditions shall
apply. Please consult the product data sheet prior to any use and processing.
Sika® Bitumen-60
SA / EN
Attestation
LEED Product Information acc. to LEED v2009 for New Construction and Major Renovations.
Sika certifies based on the present state of knowledge, that the product
Sika® Bitumious-60
Has been tested and evaluated for the VOC content. The VOC content is less than 30 g /l
(less water).
However with LEED certification there is no requirement for products applied to the
exterior of a building to have restrictions on VOC content because it does not affect indoor
air quality.
Sika Saudi Arabia Ltd ⋅ Prince Sultan Street - Obaikan Building - PH Floor - KSA Phone: +966 12 692 7079
Fax: +966 12 692 1272 gcc.sika.com
Job Reference & Approvals