0% found this document useful (0 votes)
45 views2 pages

I 410 PWS Process Weighing Software: Example of Printout

The document provides information about Precia Molen's I 410 PWS process weighing software. It allows a weight indicator to be integrated into an industrial process controlled by a PLC or PC, displaying up to 10 weighing channels simultaneously and communicating in process or regulated mode. It also monitors 4 weight thresholds and supports remote displays and printers. The software has different user levels for configuration and is designed to integrate easily into various industrial processes.

Uploaded by

Khalid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views2 pages

I 410 PWS Process Weighing Software: Example of Printout

The document provides information about Precia Molen's I 410 PWS process weighing software. It allows a weight indicator to be integrated into an industrial process controlled by a PLC or PC, displaying up to 10 weighing channels simultaneously and communicating in process or regulated mode. It also monitors 4 weight thresholds and supports remote displays and printers. The software has different user levels for configuration and is designed to integrate easily into various industrial processes.

Uploaded by

Khalid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

I 410 PWS

Example of printout Process Weighing Software

www.preciamolen.com
Weight ticket:
General Operator interface
The I 410 PWS software enables the I 410 weight indicator to be
integrated into an industrial process controlled by a PLC or a PC. 1
2
The main features are: 3
4
 simultaneous display of 10 weighing channels.
5
 communication with a PLC or PC in process or regulated
mode. 6

www.preciamolen.com
 the monitoring of 4 weight thresholds and an analogue
4-20 mA output for each channel. 7 8
 support of remote display and printing devices.
9

Configuration

The operating parameters within the I 410 system are


List of printable data: independently configurable for each channel and are structured 1. Main screen of the application (weight display for the
in files based on four levels of access via password: selected channel).
• Engineer: 2. F1 to F6: Selection of scales from 1 to 6.
• 3 header lines or company name (configurable in the Port Metrological adjustment and Input/Output configuration. 3. F7: Set scale to "0 kg".
Series file) • Supervisor: 4. F8: Set Tare
• Date/time Configuration, Serial port 5. F9: Cancel tare (gross return).
• DSD number • Operator: 6. F10: Print.
• Weight
Configuration of thresholds. 7. SF1 to SF3: Display scales (1 to 5), (6 to 10) or (1 to 10)
• 2 lines of text at bottom of ticket
• User: 8. SF4: File access (configuration).
Configuration by selecting the type of weight information: Limited rights for viewing and printing. 9. Validation (Enter) key.
• gross weight
This modular approach and segmentation of parameters enables The function of keys F1 to F10 and SF1 to SF4 are illustrated by
• net weight the I 410 system to be easily integrated into the majority of the pictogram associated with the key. The function of each key
• Gross/Tare/Net Weight on one line industrial processes. It also provides security of operation by may vary depending upon the current position within the
• Gross/Tare/Net Weight on 3 lines denying access to unauthorised operators. application.

Minimum configuration Features


 I 410 operator terminal,
Communication by fieldbus
 A weight transmitter or a measuring module fitted in the
operator terminal Support for fieldbus:
 Profibus*
 Profinet**
 Ethernet TCP/Modbus*
 DeviceNet**
 Ethernet/IP**

Serial link communication


RS232 or RS485 serial of protocols:
 Modbus RTU
 PRECIA A + (multi-channel slave and single-channel master)

Weight thresholds
4 weight thresholds assignable to 4 digital outputs may be
defined for each of the 10 weighing channels.

04-41-54-1 FT - 11/2014
The thresholds can be defined as gross or net weight.
Your Authorised Distributor Non contractual illustrations. Precia-Molen reserves the right to alter the characteristics of the equipment described in this brochure
at any time.
The digital outputs can be assigned to any physical outputs
Head Office & Plant PRECIA-MOLEN available: transmitter, WAGO terminal or remote interface.
BP 106 - 07000 Privas - France
Tel. 33 (0) 475 664 600
Fax 33 (0) 475 664 330
E-MAIL [email protected] * integrated map of the terminal or external coupler.
** only on external coupler.
RCS: 386 620 165 RCS Aubenas
Features (continued) Block diagram
Display I 410 G - Coupler
Customer field
bus Customer system
Configurable text up to 10 alphanumeric characters for each of the weighing channels. • Profibus • Ethernet TCP/ Modbus • Automatic control system
• Profinet • Ethernet IP • Supervision
• Device Net • Etc ...
1 2 3

PLC (Modbus) or PC

CAN Bus
I 410 - Graphic terminal*
Field bus interface Displays
1. Display of all 10 weighing channels on 2 screens (5 channels each) [SF1 <--> SF2). • Profibus DP T1, T2, T3, T4 or T5

www.preciamolen.com
• Ethernet TCP/ Modbus Path displayed or addressable
2. Display of the selected channel.
3. Reduced display of 10 channels on a single screen. Port S1 and/or S2
RS 232 Serial USB
Remote control Data Storage Device (DSD) USB
Printer
RS 485/422 memory stick P255, P360, P140 or LQ300
 Data Storage Device (DSD) :
For each of the 10 weighing channels a digital input can be DSD
configured to enable a remote command such as zero setting or • Max. number of records .......................................................... 38 000. Port S1 to S6
print request. • Record contains: DSD no., gross weight, tare weight, net
weight, predetermined tare, type of weight printed, type of Digital Inputs/outputs
Digital outputs can be assigned to any physical inputs available: weight transmitted by protocol, units, serial no.. Analogue Output 4-20 mA USB memory stick
transmitter, WAGO terminal or remote interface. • For trade use application via a PLC or PC to obtain a weight

CAN Bus
value associated with an approved weight serial number
Weight information on 4-20 mA analogue output (DSD) • 2 inputs
• 4 outputs A+ Protocol
The weight value can be either Gross Weight or Net Weight. Identification of scales • 4-20 mA output
Information can be delivered for Gross weight or current Net  Characteristics
weight.
File Capacity Code Label Access level
Analogue outputs can be assigned to any physical analogue Scales 10 2c. num. 10c. alpha. Operator I 400 TB - Transmitter T1
outputs available: transmitter, WAGO terminal or remote Measurement
interface. Possibility for the operator to modify the thresholds values to
check for each scale.
BCD Weight Output
Weight ticket (see sample printout)
Scale 1
6 inputs / 6 outputs digital • 6 inputs
The weight value from one of the 10 weighing channels is also

CAN Bus
Connection to a printer type P255, P360, P140 or LQ300 via an • 6 outputs
available via a BCD interface
RS232 serial link. • 4-20 mA output
Requires the use of a set of remote WAGO inputs/outputs.
Printing triggered by pressing a terminal key, by remote control
on digital input, by the fieldbus or by Modbus serial link or A +. I 400 TB - Transmitter Tn*
Outputs:
• 5 digits 1/2 weight Measurement
Remote weight display
• No motion
• Gross/Net Connections available to 1 to 5 D200 or D570 weight displays via
• Out of range an RS232 or RS485 serial link. 6 inputs / 6 outputs digital • 6 inputs
• Watchdog (strobe) Scale n*
• 6 outputs
USB memory stick • 4-20 mA output
Inputs:

CAN Bus
• Get weight Complete backup/restore of all parameters via the USB drive
• Zero request
• Calibration request
External I/O Module (WAGO)
• Gross weight reset

Control of input/output by the PLC 64 inputs/64 outputs

All physical I/Os (digital or analogue) can be used by the PLC as


remote I/Os.

This control can be done via a field bus or serial Modbus protocol *) Management of 1 to 10 Transmitters. It is possible to include one or two internal weighing channels in the graphic terminal.
link.