Controllers and Segments

An NT8D01 controller card is installed in each IPE shelf between slots 7 and 8 and interfaces up to 4 superloops to an IPE module. An NT8D37 IPE module is divided into four segments of four card slots numbered 0-3, where a superloop can be assigned to one to eight segments. The controller is the IPE card between slots 7 and 8 which would flash C0 and a number depending on the shelf, relating to the XPEC assigned to the controller.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views2 pages

Controllers and Segments

An NT8D01 controller card is installed in each IPE shelf between slots 7 and 8 and interfaces up to 4 superloops to an IPE module. An NT8D37 IPE module is divided into four segments of four card slots numbered 0-3, where a superloop can be assigned to one to eight segments. The controller is the IPE card between slots 7 and 8 which would flash C0 and a number depending on the shelf, relating to the XPEC assigned to the controller.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Controllers and Segments

Mike's PBX Cookbook


Home Meridian VoIP IP Office BCM Norstar VMail Record Other
Administration Maintenance Installation Hardware Contents

Controllers and Segments


The image right is a NT8D01 controller card. It's installed in each IPE shelf between slots 7 and 8, and interfaces upto 4
Superloops to an IPE module.

See also Network Loop Configurations and Superloops / Controllers.

An NT8D37 IPE Module is divided into four segments of four card slots, numbered 0-3. Segment 0 consists of slots 0-3, segment 1 consists of
slots 4-7, segment 2 consists of slots 8-11, and segment 3 consists of slots 12-15. A superloop can be assigned from one to eight IPE
segments.

IPE Module with four segments:

NT8D37 IPE Module Segments

To print the relationship between


Superloops and controllers...

Go to LD 97, and print the superloops:

REQ: PRT
TYPE: SUPL
SUPL: (hit return)

All Superloops will print.

Next, print the controllers:

REQ: PRT
TYPE: XPE

http://pbxbook.com/meridian/hardware/slxpec.html[26/01/2016 16:13:40]
Controllers and Segments

XPEC: (hit return)

You will see all controllers and which Superloop(s) are assigned to them.

SUPL SUPT SLOT XPEC0 XPEC1

004 STD LEFT 01 0 3 02 0 3


024 STD LEFT 03 0 3 -- - -
100 ---- ---- PHANTOM -- - -
148 ---- ---- VIRTUAL -- - -

S0 S1 S2 S3 LOC DIS RGTP


01 004 004 004 004 NO 08
02 004 004 004 004 NO 08
03 024 024 024 024 NO 08

An IPE is split into 4 segments. A superloop can service from 1 to 8 segments. The controller is the IPE card between slots 7 and 8. Here, it
would flash C0 and either 01, 02 or 03 depending on what shelf you are looking at, this is its "controller number". This is related to the XPEC
assigned to the controller. In this example:

Loop 4 shelf 0 = Controller 01, segments 0 to 3 (XPEC 0)


Loop 4 shelf 1 = Controller 02, segments 0 to 3 (XPEC 1)
Loop 24 Shelf 0 = Controller 03, segments 0 to 3 (XPEC 0)

Note: Superloop 4 is split between two controllers/shelves.