0% found this document useful (0 votes)
2K views2 pages

Handleiding Iskra ME162

The document discusses the ME162 single-phase electronic energy meter. It is intended for measuring electric energy and registration in single-phase two-wire networks for households and small commercial users. The meter complies with international IEC standards and measures active power consumption accurately in one or two directions. It has features like an internal clock, LCD display, communication port, and output ports.

Uploaded by

RichardBertrand
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

Handleiding Iskra ME162

The document discusses the ME162 single-phase electronic energy meter. It is intended for measuring electric energy and registration in single-phase two-wire networks for households and small commercial users. The meter complies with international IEC standards and measures active power consumption accurately in one or two directions. It has features like an internal clock, LCD display, communication port, and output ports.

Uploaded by

RichardBertrand
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Energy Measurement and Management

ME162
The ME162 single-phase electronic meters are intended for electric energy measurement and registration in single-phase two-wire networks in household. The meter is approved and manufactured in compliance with the IEC 62052-11, IEC 62053-21 (IEC 61036) standards and ISO 9001. They are designed according to even more severe Iskraemecos standards that are the result of our more than 50-year experiences of meter manufacturing and fifty million meters installed worldwide.

Single-phase meter

Active power

Single or double direction

I Internal clock I Data display on LCD in voltage-free state (option) I LCD backlight (option) I Communication optical port for semi-automatic meter reading

Multi-rate registration

Internal clock

Data display

I Smaller dimensions I Energy measurement: one direction, double direction or absolute

Impulse output (KWh)

ME162

FUNCTIONAL AND TECHNICAL DATA


ME162 is a single-phase meter for residential and small commercial users, for revenue measuring of active power in two wire systems. Measuring and registration: Standard (as a mechanical meter). Other options: Double direction Always positive (absolute) Accurracy/calibration: Due to the long-term stability there is no need for recalibration in meters life-time. Indications: LED 1 (red): kWh impulses (k=1000 imp/kWh) Illuminated: meter is powered, no load current Pulsating: load current is higher than starting value Not illuminated: meter is not powered Communication: Opto-port (IEC 62056 21): for local meter reading and programming. Real time clock: 32 kHz quartz oscillator The real time clock generates: a tariff program, season changeover, transition to day light saving period and vice-versa. Inputs tariff: Two tariff inputs for 2-4 tariff energy registration. Outputs: S0 (DIN 43864) or opto-MOS-relay. Option: two separate S0 or optomos outputs for bi-directional energy flow direction (kWh-import, kWh- export). Local metering data display (LCD): Automatic scroll mode Manual scroll (by button)Programmable data set and sequence LCD back-light (option) Data display on LCD in voltage-free state (option). Scroll key: LCD test Scrolling data on LCD Enclosure: Polycarbonate, self-extinguishable. Protection against water and dust: IP 53.

Accuracy class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 or 1 Rated current In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5, 10, 20 A Max. current Imax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85, 100 A Min. current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,05 In Starting current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,004 Ib Reference voltage Un . . . . . . . . . . . . . . . . . . . . . . . .120, 220, 230, 240 V Voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,8 Un ... 1,15 Un Reference frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50, 60 Hz Meter constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 imp/kWh Clock accuracy (25C) . . . . . . . . . . . . . . . . . . . 6 ppm or 3 min/year RTC control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 kHz crystal Temperature range of operation . . . . . . . . . . . . . . . . . . . .-25C ... +60C Extended temp. range . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40C ... +70C Storing temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40C ... +85C Current circuit burden . . . . . . . . . . . . . . . . . . . . . . . . .<25 mW / 25 mVA Voltage circuit burden . . . . . . . . . . . . . . . . . . . . . . . . . . . .<0.8 W / 10 VA Dielectric strength (burst test) . . . . . . . . . . . . . . . . . . .4 kV, 50 Hz, 1 min Impulse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 kV, 1,2/50 s Short-circuit current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Imax EMC: High frequency disturbances . . . . . . . . . . . . . .6 kV (IEC 1000-4-4) Optical port . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEC62056-21 (IEC 61107) Impulse outputs: S0 . . . . . . . . . . . . . . . . . . . . .ti = 40 ms (10 , 20, 30, ..., 160 ms) opto-MOS . . . . . . . . . . . . . . .ti = 80 ms (10 , 20, 30, ..., 160 ms) Switching power . . . . . . . . . .25 VA (100 mA, 250 V) Dimensions (h x w x d) . . . . . . . . . . . . . . . . . . . . . . . .97 x 130 x 43 mm Mass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Approx. 0.380 kg

CONNECTION DIAGRAMS

Z1

Z2
+AA -AA

Z1

Z2
+AA -AA

1 2 3 4 5 6

15 13 33 20 21 22

TYPE DESIGNATION FOR OREDERING ME162D1A41V22G22M3K0


M E 162 D1 D3 A4 A5 1 2 4 V12 V22 G12 G22 L11 L21 M 3 K0 Electronic meter Single-phase meter Meter with LCD and internal clock Terminal block for direct connection up to 85 A by DIN 43857 Terminal block for direct connection up to 100 A by BS 5685 Active energy measurement, accuracy class 1 Active energy measurement, accuracy class 2 Energy measurement in one direction Energy measurement in two directions Absolute energy measurement 1 tariff input 2 tariff inputs 1 impulse S0 output 2 impulse S0 outputs 1 OPTOMOS relay, make contact 2 OPTOMOS relays, make contact Additional device Real time clock with Li-battery Communication interface. Optical interface IEC 62056-21 (IEC 61107)

15 13 33 20 21 22

MAIN

LOAD

L1 N

DIMENSIONS

0411/50

Owing to periodical improvements of our products the supplied products can differ in some details from the data stated in the prospectus material.

Iskraemeco, Energy Measurement and Management 4000 Kranj, Savska loka 4, Slovenia Telephone: (+386 4) 206 40 00, Telefax: (+386 4) 206 43 76, http://www.iskraemeco.si, e-mail: [email protected] Published by Iskraemeco. Data subject to alteration without notice.