0% found this document useful (0 votes)
574 views4 pages

RCC Slab Design

This document summarizes the design of a reinforced concrete slab with dimensions of 1m x 1.2m and a thickness of 250mm. It includes calculations of loads, bending moments, required reinforcement, shear strength, and deflection. The slab is designed as a two-way slab with reinforcement provided at 150mm spacing in both directions to resist the bending and shear loads. All design checks for moment capacity, shear strength, and deflection are satisfied by the provided reinforcement.

Uploaded by

arghyadeep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
574 views4 pages

RCC Slab Design

This document summarizes the design of a reinforced concrete slab with dimensions of 1m x 1.2m and a thickness of 250mm. It includes calculations of loads, bending moments, required reinforcement, shear strength, and deflection. The slab is designed as a two-way slab with reinforcement provided at 150mm spacing in both directions to resist the bending and shear loads. All design checks for moment capacity, shear strength, and deflection are satisfied by the provided reinforcement.

Uploaded by

arghyadeep
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Design of Slab

Panel Size : Lx = 1.000 m Grade of Concrete ( fck) = 30 N/mm2


Ly = 1.200 m Grade of Steel ( fy) = 500 N/mm2
Weight of Concrete = 25 kN/m3
Slab thickness = 250 mm

Dead Load
Weight of Slab = 6.3 kN/m2
Wt of floor finish = 0.92 kN/m2
7.17 kN/m2

Live Load
Floor Live Load = 80.00 kN/m2

Loading Intensity : DL = 7.2 kN/m2


LL = 80.0 kN/m2
Total Load (w) = 87.17 kN/m2

Ly / Lx = 1.200 So it is to be designed as a two-way slab

From Table 26 of IS 456 : 2000, (Two Adjacent edges discontinuous)


short span co-efficient ax = -0.06
0.045
long span co-efficient ay = -0.047
0.035

Shorter Direction
Maxm hogging moment = 5.2 kNm/m
Maxm sagging moment = 3.9 kNm/m

Longer Direction
Maxm hogging moment = 4.1 kNm/m
Maxm sagging moment = 3.1 kNm/m

Load Factor = 1.5 , Mu (-) = 8 kNm/m


6 kNm/m
Mu (+) = 6 kNm/m
5 kNm/m
Shorter direction
Reinforcement at top

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 8 mm
Effective depth (d) = 213 mm
Mu/bd2 = 0.17
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.040 %
Ast required = 85 mm2
Spacing required = 589 mm
Spacing provided = 150 mm

Reinforcement at bottom

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 8 mm
Effective depth (d) = 213 mm
Mu/bd2 = 0.13
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.030 %
Ast required = 64 mm2
Spacing required = 788 mm
Spacing provided = 150 mm

Longer direction
Reinforcement at top

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 10 mm
Effective depth (d) = 210 mm
Mu/bd2 = 0.14
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.120 %
Ast required = 252 mm2
Spacing required = 312 mm
Spacing provided = 150 mm
Reinforcement at bottom

Overall depth (D) = 250 mm


Clear cover = 25 mm
Dia of bar = 10 mm
Effective depth (d) = 210 mm
Mu/bd2 = 0.10
Grade of concrete = M 30
Grade of reinforcement = Fe 500
pt = 0.120 %
Ast required = 300 mm2
Spacing required = 262 mm
Spacing provided = 150 mm

Check For Shear

Shear stress = (15.92 X 1000 X 1000) X 1.5 X 0.6

1000 X 1000X 152


( As per Table 13 of IS:456-2000, the shear co-efficient is 0.6
for support next to end support which is maximum)
= 0.31 N/mm2

Maximum percentage of reinforcement provided (pt) = (100 X 1000 X 122 X π)


(4 X 150 X 1000 X 152)
= 0.36 %

Shear strength of concrete (τc) = 0.5 N/mm2 (As per Table-19 of


IS:456-2000)

As per Cl. 40.2.2.1 of IS:456-2000,

k = 1.2 (For overall slab depth of 250mm)

Therefore, Design shear strength for concrete = τc X k


= 0.6 N/mm2 > 0.16 N/mm2

(Hence, OK)

Check For Deflection

Span = 1.000 m

Span by Depth Ratio = 20


Steel stress of service (fs)= 0.58*fy* Area of cross-section of steel required
Area of cross-section of steel provided

= 35.35 N/mm2

Percentage of tension reinforcement= 0.36 %

Modification factor for tension reinforcement (k t)= 2 (Ref. Fig 4 of IS:456-2000)

Percentage of compression reinforcement= 0.36 %

Modification factor for compression reinforcement (k c)= 1.15 (Ref. Fig 5 of IS:456-2000)

(L/d)theo = (L/d)required*kt*kc*kf
= (20 X 2 X 1.095 X 1)
= 46

(L/d)provided= (L/d)act = ( 3090 / 152)


= 4.69 < 46 OK

Hence Ok for Deflection Check

Output Data

Slab Thickness 250mm

T 12@ 150
B 12@ 150

T12 @150
T 12 @150