CP10 CH

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

CP10

Service Information

Laney
Classic British Amplification
Newlyn Road, Cradley Heath, West Midlands. B64 6B£
www.laney.co.uk
1 2 3 4 5 6 7 8

Line In
SK1 Treble
MJACK
VR2
C12 C18 22KB C19
R6
10K
Volume R24
Gi R1 10U 50V 15nF 15nF C27
VR1 R22 1M
100K 220P 250V
100KA6S 2K2
Link Out -15V
C1
+15V C17 R25 R3
Gi U3A +28V External Loudspeaker
A SK3 A
MJACK D7 LN23 TL072 330R 10K
LN21 47P 50V 47U 50V
1N4148 R23
0R0 Gi
2K2 0R0
LN20 10uF C6
U2B R19 R20 +15V R18
0R0 Gi C10
Gi Gi TL072 100N 100V SP3 SP4
Gi D8 1K 1K R13 2K2 7 13
VR3 U1 SPADE4.8 SPADE4.8
1N4148 C100 22KB 1U 63V 10K C8
R9 +VI +VP G
3K3
C15
-15V Gi C20 Bass 470P 250V
-IN
10P 50V 2 +IN
Gi Gi OUT 14
47U 50V R12 3 G
SK4 220nF Gi GIN C2
C3 +15V 4 TDA7294
Mic SJACK R7 47K 22UF 50V R17
D1 R14 STBY BS 6 SP2
U2A R16 9 10R 2W5 SPADE4.8
1K MUTE
TL072 10
470P 250V
470P 250V 2K2
1N4148 10K
1
MSGND
C11
-V
C21 C22 R8 R11 C5 C7 R15
Gi 4K7 100U 25V 22K -VI -VP 100N 100V
-15V 4U7 63V SP1
1K R10 G
47U 50V -28V SPADE4.8
R2 R4 C4
3K3
To internal Loudspeaker +V
100K 100K C16 Gmu Gi
C9
Gi Gi 10P 50V 100N 100V
R5
1K G

D2
1N4007
B B

Mains In These items not on pcb D3


+28V
230V = T1A, 115V = T2A P7
IEC Inlet Fuse
Mains Switch AC Line(Live)
Black(Brown) PAD3 1N5404 C13
Green/Yellow D4 3300U 50V
Fuse Integral to IEC From Transformer secondary 1N5404
Link to chassis
P8 VIRTUALSHORT
AC Input (Neutral)
White (Blue)
Chassis Transformer Primary
PAD3
MAINS TRANSFORMER D5 LN10 LN11
G -28V 0R0
P9
1N5404 C14
PAD3 D6 3300U 50V
Gi
1N5404 Gmu
LN2 LN3 LN4 LN5
0R0 0R0 0R0 0R0

Flame proof resister Chassis


FP Must only be replaced with same type and rating

Indi cates safety critical component


C Must only be replaced with approved type C

PSU
+28V
+15V
R26
680R 5W
C23 D9
470U 16V C25
15V ZD1.3W 100N 63V

Gmu
C24 D10 C26 Gi
470U 16V 15V ZD1.3W 100N 63V
Power LED
R27 R21 D11

680R 5W 4K7
-15V LED3MMR
-28V Gi

D D

Revision History Title


Flame proof resister C100 from 1uF to 10uF CP10 PCB
BLT
60WFINNEDHS FP Must only be replaced with same type and rating C18,C19 from 2n2 to 15n
C20 from 47n t o 220n
R19,R20 from 4k7 to 1K Issue 2 Size Number Revision
See CN0334
Indi cates safety critical component
Must only be replaced with approved type
R22 from 8K2 to 2K2
R23 from 22K to 2K2 Industries A3 9360 2
VR2,VR3 f rom 100KB to 22KB
Date: 20/01/2004 9360_2.sch Sheet 1 of 1
File: D:\9360_2-SHENJIE\9360_2.sch Drawn By: Rich Thompson