KABELINDO
KABELINDO
KABELINDO
Low Voltage
Cu/PVC/PVC 300/500 V (NYM) Copper Conductor PVC Insulated and PVC Sheathed Indoor Cable 3-5
Cu/PVC 450/750 V (NYAF) Single Core Flexible Copper Conductor PVC Insulated 6
Cu/PVC/PVC 300/500 V (NYMHY) Multi Core Flexible Copper Conductor PVC Insulated & PVC Sheathed 7
Cu/PVC/PVC 0.6/1 kV (NYY) Copper Conductor PVC Insulated & PVC Sheathed 8 - 12
non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV Control Cable (NYY) Copper Conductor PVC Insulated & PVC Sheathed 13 - 14
non Armoured Control Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY) Copper Conductor PVC Insulated & PVC Sheathed 15 - 18
Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV Control Cable (NYFGbY) Copper Conductor PVC Insulated & PVC Sheathed 19 - 20
Armoured Control Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY) Copper Conductor PVC Insulated & PVC Sheathed 21 - 24
Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV Control Cable (NYRGbY) Copper Conductor PVC Insulated & PVC Sheathed 25 - 26
Armoured Control Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY) Copper Conductor PVC Insulated, Copper tape Screened and 27 - 30
PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV Control Cable (NYSY) Copper Conductor PVC Insulated, Copper tape Screened and 31 - 32
PVC Sheathed Cotrol Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY) Copper Conductor PVC Insulated, Concentric Copper wire Screened 33 - 35
and PVC Sheathed Power Cable
Cu/PVC/CWS/PVC 0.6/1 kV Control Cable (NYCY) Copper Conductor PVC Insulated, Concentric Copper wire Screened 36 - 37
and PVC Sheathed Control Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY) Copper Conductor PVC Insulated & PVC Sheathed 38 - 41
Armoured Power Cable
Cu/PVC/DSTA/PVC 0.6/1 kV Control Cable (NYBY) Copper Conductor PVC Insulated & PVC Sheathed 42 - 43
Armoured Control Cable
Derating Factors 44 - 48
Standards 50
www.kabelindo.co.id
Copper Conductor PVC Insulated Building Wire
Cu/PVC 450/750 V (NYA)
Specification :
SPLN 42-1 : 1991
IEC 227
SNI 04-6629 : 3-2006
Constructions: Applications:
1. Conductor: Permanent installation in conduit or exposed wiring in dry location.
Annealed plain copper round solid or round circular stranded
according to SPLN 4 2 - 3 ; IEC 60228 Note : [re] round solid conductor
[rm] circular stranded conductor
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC) complied with Packing : [C] Coil
SPLN 41-2 [D] Drum
Identification:
Yellow/Green strip, Light Blue, Black, Yellow, Red colour
[email protected] 1
Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable
Cu/PVC/PVC 300/500 V (NYM)
Specification :
SPLN 42-2 : 1992
IEC 227
SNI : 04-6629.4-2006
Constructions: Applications:
1. Conductor: Permanent installation in conduit under plaster or exposed wiring
Annealed plain copper round solid or round circular in dry location.
stranded according to SPLN 42 - 2 ; IEC 60228
Note : [re] round solid conductor
2. Insulation: [rm] circular stranded conductor
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2 Packing : [C] Coil
[D] Drum
Identification of core Identification of core
Light Blue, Black (SPLN) Ligh Blue, Brown (SNI)
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], White colour
2 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable
Cu/PVC/PVC 300/500 V (NYM)
Specification :
SPLN 42-2 : 1992
IEC 227
SNI : 04-6629.4-2006
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular
stranded according to SPLN 4 1 - 1 ; IEC 60228
3. Inner Covering / filler:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour
Extruded layer of Polyvinyl Chloride (PVC] complied with
SPLN 41-2 4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], White colour
Identification of core (SPLN)
Applications:
Colour of insulation Permanent installation in conduit under plaster or exposed wiring
No. of cores in dry location.
System - i System - o
Three Yellow/Green strip, Light Blue, Black Light Blue, Yellow, Black
Four Yellow/Green strip, Light Blue, Yellow, Black Light Blue, Red, Yellow, Black
Note : [re] round solid conductor
[rm] circular stranded conductor
4x1.5 re 0.7 1.2 9.9 159 178 12.1 50 19 16 0.55 0.24 0.17 100/C
4x1.5 rm 0.7 1.2 10.3 169 185 12.1 50 19 16 0.55 0.24 0.17 100/C
4x2.5 re 0.8 1.2 10.9 214 196 7.41 50 25 22 0.91 0.41 0.29 100/C
4x2.5 rm 0.8 1.2 11.5 230 207 7.41 50 25 22 0.91 0.41 0.29 100/C
4x4 re 0.8 1.4 12.9 313 232 4.61 50 34 30 1.45 0.65 0.46 100/C
4x4 rm 0.8 1.4 13.6 338 245 4.61 50 34 30 1.45 0.65 0.46 100/C
4x6 re 0.8 1.4 14.1 411 254 3.08 50 44 39 2.18 0.98 0.69 100/C
4x6 rm 0.8 1.4 15 446 270 3.08 50 44 39 2.18 0.98 0.69 100/C
4x10 rm 1.0 1.4 18.5 701 333 1.83 50 61 53 364 1.63 1.15 100/C
4x16 rm 1.0 1.4 21 987 378 1.15 40 82 71 5.82 2.60 1.84 1000/D
4x25 rm 1.2 1.6 25.9 1,530 466 0.727 40 108 94 9.09 4.07 2.88 1000/D
4x35 rm 1.2 1.6 28.9 2,014 520 0.524 40 134 117 12 73 5.69 4.03 1000/D
[email protected] 3
Copper Conductor PVC Insulated & PVC Sheathed Indoor Cable
Cu/PVC/PVC 300/500 V (NYM)
Specification :
SPLN 42-2 : 1992
IEC 227
SNI : 04-6629.4-2006
Constructions: Applications:
1. Conductor: Permanent installation in conduit under plaster or exposed wiring in
Annealed plain copper round solid or round circular stranded dry location.
according to SPLN 4 1 - 1 ; IEC 60228
Note : [re] round solid conductor
2. Insulation: [rm] circular stranded conductor
Extruded layer of Polyvinyl Chloride [PVC] complied with
SPLN 41-2 Packing : (C) Coil
(D) Drum
Identification of core: [SPLN]
Yellow/Green strip, Light Blue, Red, Yellow, Black,
4. Outer sheath:
Extruded Polyvinyl Chloride [PVC], White colour
4 www.kabelindo.co.id
Single Core Flexible Copper Conductor PVC Insulated
Cu/PVC/PVC 450/750 V (NYAF)
Specification :
SPLN 42-3 : 1992
IEC 227
SNI : 04-6629.5-2006
Constructions: Applications:
1. Conductor: Used for fixed installation inside appliances, switchgear and
Annealed plain copper wires bunch stranded, according to controlgear.
SPLN 41-1; IEC 60228 Note : [f] Flexible bunched wire
Identification:
Yellow/Green strip, Light Blue, Black, Yellow, Red colour
[email protected] 5
Multi-Core Flexible Copper Conductor PVC Insulated & PVC Sheathed
Cu/PVC/PVC 300/500 V (NYMHY)
Specification :
SPLN 42-6 : 1991
IEC 227
SNI : 04-6629.5-2006
Conductor Nominal thickness DC. Resistance Current Carrying Short Circuit Current
Weight Minimum at 20°C Capacity in air Capacity at Standard
Nominal No. of wire Overall of Cable bending
cross and Insulation Outer Diameter radius radius Conductor Insulation delivery
30°C 40°C 0.1 sec 0.5 sec 1.0 sec
section Diameter Sheath (approx) Max Min
length
area of wire
sq.mm mm mm mm mm mm mm Ohm/km M.Ohm.km A A kA kA kA m
2 x 0.5 f 16/0.2 0.6 0.8 6 56 108 39 40 2 1.8 0.18 0.08 0.06 100/C
2 x 0.75 f 24/0.2 0.6 O.B 6.5 56 117 26 40 6 5.5 0.27 0.12 0.09 100/C
2 x 1.0 f 32/0.2 0.6 0.8 6.7 66 121 19.5 40 10 9.2 0.36 0.16 0.12 100/C
2 x 1.5 f 30/0.25 0.7 0.9 7.7 90 139 13.3 40 15 13.8 0.55 0.24 0.17 100/C
2 x 2.5 f 50/0.25 0.8 1.0 9.4 140 169 7.98 40 20 18.4 0.91 0.41 0.29 100/C
2x4f 56/0.3 O.B 1.0 11.3 209 203 4.95 40 27.5 25.3 1.45 0.65 0.46 100/C
3 x 0.5 f 16/0.2 0.6 0.8 6.4 60 115 39 40 2 1.8 0.18 O.OB 0.06 100/C
3 x 0.75 f 24/0.2 0.6 0.8 6.8 77 122 26 40 6 5.5 0.27 0.12 0.09 100/C
3 x 1.0 f 32/0.2 0.6 0.8 7.1 90 128 19.5 40 10 9.2 0.36 0.16 0.12 100/C
3 x 1.5 f 30/0.25 0.7 O.B 8.3 147 149 13.3 40 15 13.8 0.55 0.24 0.17 100/C
3 x 2.5 f 50/0.25 0.8 1.0 10.2 190 184 7.98 40 20 18.4 0.91 0.41 0.29 100/C
3x4f 56/0.3 0.8 1.0 12 265 216 4.95 40 27.5 25.3 1.45 0.65 0.46 100/C
4 x 0.5 f 16/0.2 0.6 0.8 7 70 126 39 40 2 1.8 0.18 0.08 0.06 100/C
4 x 0.75 f 24/0.2 0.6 O.B 7.4 96 133 26 40 6 5.5 0.27 0.12 0.09 100/C
4 x 1.0 f 32/0.2 0.6 O.B B 121 144 19.5 40 10 9.2 0.36 0.16 0.12 100/C
4 x 1.5 f 30/0.25 0.7 0.9 9.1 167 164 13.3 40 15 13.B 0.55 0.24 0.17 100/C
4 x 2.5 f 50/0.25 0.8 1.0 11.2 237 202 7.98 40 20 18.4 0.91 0.41 0.29 100/C
4x4f 56/0.3 0.8 1.0 13.1 330 236 4.95 40 27.5 25.3 1.45 0.65 0.46 100/C
5 x 0.5 f 16/0.2 0.6 O.B 7.B 90 140 39 40 2 1.8 0.18 O.OB 0.06 100/C
5 x 0.75 f 24/0.2 0.6 O.B B.3 116 149 26 40 6 5.5 0.27 0.12 0.09 100/C
5 x 1.0 f 32/0.2 0.6 0.8 8.7 139 157 19.5 40 10 9.2 0.36 0.16 0.12 100/C
5 x 1.5 f 30/0.25 0.7 0.9 10.3 194 185 13.3 40 15 13.8 0.55 0.24 0.17 100/C
5 x 2.5 f 50/0.25 0.8 1.0 12.4 291 223 7.98 40 20 18.4 0.91 0.41 0.29 100/C
5x4f 56/0.3 0.8 1.0 14.3 391 257 4.95 40 27.5 25.3 1.45 0.65 0.46 100/C
6 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded Applications:
according to SPLN 4 1 - 1 ; IEC 60228 Indoor and outdoor induct installation or of laying in the ground
where not sustain mechanical damage.
2. Insulation:
Extruded layer of Polyvinyl Chloride [PVC] complied with SPLN Note : [re] round solid conductor
41- 2: IEC 60502-1 [rm] Circular stranded conductor
3. Outer Sheath:
Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
request.
[email protected] 7
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
8 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
[email protected] 9
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
10 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
2. Insulation: Applications:
Extruded layer of Polyvinyl Chloride (PVC) complied with SPLN Indoor and outdoor induct installation or of laying in the ground
41-2 : IEC 60502-1 where not sustain mechanical damage.
[email protected] 11
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor: 3. Inner Covering / filler:
Annealed plain copper round solid or round circular stranded Extruded Polyvinyl Chloride [PVC], Black colour
according to SPLN 4 1 - 1 ; IEC 60228
4. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : special flame retardant. PVC sheath can be provided on request
IEC 60502-1
Applications:
Identification of core (SPLN) Indoor and outdoor induct : installation or of laying in the ground where
not sustain mechanical damage.
Colour of insulation
System - i System - 0
Note : [re] round solid conductor
Yellow/Green strip, Black with White number Black with White number
[rm] circular stranded conductor
12 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed non Armoured Control Cable
Cu/PVC/PVC 0.6/1 kV (NYY)
Specification :
SPLN 43-1 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
2. Insulation: Applications:
Extruded layer of Polyvinyl Chloride (PVC] complied with Indoor and outdoor induct : installation or of laying in the
SPLN 41-2 : IEC 60502-1 ground where not sustain mechanical damage.
[email protected] 13
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized flat steel wires with a counter helix layer of
Annealed plain copper round solid or round circular stranded galvanized steel tape.
according to SPLN 4 1 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : or special flame retardant, PVC sheath can be provided on request.
IEC 60502-1
Applications:
Identification of core (SPLN) For general purpose power distribution in dry or wet location, best
Light Blue, Black suitable for direct burying in ground.
14 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60902-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized flat steel wires with a counter helix layer
Annealed plain copper round solid or round circular stranded or of galvanized steel tape.
sector shape according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : and/or special flame retardant, PVC sheath can be provided on
IEC 60502-1 request.
[email protected] 15
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized flat steel wires with a counter helix layer
Annealed plain copper round solid or round circular stranded or of galvanized steel tape.
sector shape according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : and/or special flame retardant, PVC sheath can be provided on
IEC 60502-1 request.
16 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized flat steel wires with a counter helix layer
Annealed plain copper round solid or round circular stranded of galvanized steel tape.
according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with and/or special flame retardant, PVC sheath can be provided on
SPLN 41-2 : IEC 60502-1 request.
[email protected] 17
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions:
1. Conductor: 4. Armour :
Annealed plain copper round solid or round circular stranded or A layer of galvanized flat steel wires with a counter helix layer
sector shape according to SPLN 41 - 1 ; IEC 60228 of galvanized steel tape.
Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
No. of of Flat of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
cores Insulation Steel sheath radius delivery
and cross Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
Size (approx) (approx]
section Max Min second second second
(nom) (nom)
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
7x1.5 re 0.8 4x0.8 1.8 18.6 727 335 12.1 50 17 13 0.55 0.24 0.17 1000/D
7x1.5 rm 0.8 4x0.8 1.8 19.2 777 346 12.1 50 17 13 0.55 0.24 0.17 1000/D
8x1.5 re 0.8 4x0.8 1.8 19.7 792 355 12.1 50 16 12 0.55 0.24 0.17 1000/D
8x1.5 rm 0.8 4x0.8 1.8 20.3 848 365 12.1 50 16 12 0.55 0.24 0.17 1000/D
10x1.5 re 0.8 4x0.8 1.8 21.7 929 391 12.1 50 15 11 0.55 0.24 0.17 1000/D
10x1.5 rm 0.8 4x0.8 1.8 22.6 997 407 12.1 50 15 11 0.55 0.24 0.17 1000/D
12x1.5 re 0.8 440.8 1.9 23 1117 414 12.1 50 14 11 0.55 0.24 0.17 1000/D
12x1.5 rm 0.8 4x0.8 1.8 23.8 1199 428 12.1 50 14 11 0.55 0.24 0.17 1000/D
14x1.5 re 0.8 4x0.8 1.8 24 1197 432 12.1 50 13 10 0.55 0.24 0.17 1000/D
14x1.5 rm 0.8 4x0.8 1.8 24.7 1287 445 12.1 50 13 10 0.55 0.24 0.17 1000/D
16x1.5 re 0.8 4x0.8 1.8 25 1310 450 12.1 50 12 10 0.55 0.24 0.17 1000/D
16x1.5 rm 0.8 4x0.8 1.9 25.6 1382 461 12.1 50 12 10 0.55 0.24 0.17 1000/D
19x1.5 re 0.8 4x0.8 1.8 26 1391 468 12.1 50 12 9 0.55 0.24 0.17 1000/D
19x1.5 rm 0.8 4x0.8 1.8 26.6 1504 479 12.1 50 12 9 0.55 0.24 0.17 1000/D
21x1.5 re 0.8 4x0.8 1.8 27 1496 486 12.1 50 11 9 0.55 0.24 0.17 1000/D
21x1.5 rm 0.8 4x0.8 1.8 27.7 1611 499 12.1 50 11 9 0.55 0.24 0.17 1000/D
24x1.5 re 0.8 4x0.8 1.9 28.2 1629 508 12.1 50 11 9 0.55 0.24 0.17 1000/D
24x1.5 rm 0.8 4x0.8 1.8 29.3 1766 527 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 re 0.8 4x0.8 1.8 30 1857 540 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 rm 0.8 4x0.8 1.8 31.4 2020 565 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 re 0.8 4x0.8 1.9 33.7 2420 607 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 rm 0.8 4x0.8 1.9 35.2 2635 634 12.1 50 11 9 0.55 0.24 0.17 1000/D
52x1.5 re 0.8 4x0.8 2.0 37.6 2932 677 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 rm 0.8 4x0.8 2.0 39.3 3190 707 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 re 0.8 4x0.8 2.1 39.5 3215 711 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 rm 0.8 4x0.8 2.1 41.3 3518 743 12.1 50 11 8 0.55 0.24 0.17 1000/D
18 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SFA/PVC 0.6/1 kV (NYFGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded 4. Armour :
according to SPLN 41 - 1 ; IEC 60228 A layer of galvanized flat steel wires with a counter helix layer
of galvanized steel tape.
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with 5. Outer sheath:
SPLN 41-2 : IEC 60502-1 Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
Colour of insulation request.
System - i System - 0
Yellow/Green strip, Black with White number Black with White number Applications:
For general purpose power distribution in dry or wet location,
(SNI IEC) best suitable for direct burying in ground.
Black with White number
Note : [re] round solid conductor
3. Inner Covering / filler: [rm] circular stranded conductor
Extruded Polyvinyl Chloride [PVC], Black colour
Packing : [D] Drum
[email protected] 19
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC :60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized round steel wires with a counter helix
Annealed plain copper round solid or round circular stranded or layer of galvanized steel tape.
according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : and/or special flame retardant, PVC sheath can be provided on
IEC 60502-1 request.
20 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized round steel wires with a counter helix
Annealed plain copper round solid or round circular stranded layer of galvanized steel tape.
according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : and/or special flame retardant, PVC sheath can be provided on
IEC 60502-1 request.
[email protected] 21
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized round steel wires with a counter helix
Annealed plain copper round solid or round circular stranded or layer of galvanized steel tape.
sector shape according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : and/or special flame retardant, PVC sheath can be provided on
IEC 60502-1 request.
Armour
No. of Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
Round
cores of of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
Steel
and cross Insulation sheath radius delivery
Wire
section Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
Diameter
area (nom) (nom) (approx) (approx) Max Min second second second
(nom)
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
4x1.5 re 0.8 0.9 1.8 15.2 433 274 12.1 50 24 18 0.55 0.24 0.17 1000/D
4x1.5 rm 0.8 0.9 1.8 15.6 455 281 12.1 50 24 18 0.55 0.24 0.17 1000/D
4x2.5 re 0.8 0.9 1.8 16 515 288 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x2.5 rm 0.8 0.9 1.8 16.7 538 301 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x4 re 1.0 0.9 1.8 18.8 740 338 4.61 50 41 34 1.45 0.65 0A6 1000/D
4x4 rm 1.0 0.9 1.8 19.7 790 355 4.61 50 41 34 1.45 0.65 0A6 1000/D
4x6 re 1.0 1.25 1.8 20.8 870 374 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x6 rm 1.0 1.25 1.8 21 925 378 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x10 rm 1.0 1.25 1.8 24 1317 432 1.83 50 69 60 3.64 1.63 1.15 1000/D
4x16 rm 1.0 1.6 1.8 26.3 1548 473 1.15 40 89 80 5.82 2.60 1.84 1000/D
4x25 rm 1.2 1.6 1.8 30A 2241 547 0.727 40 116 105 9.09 4.07 2.88 1000/D
4x35 rm 1.2 1.6 1.9 32.9 2933 592 0.524 40 138 130 12.73 5.69 4.03 1000/D
4x50 sm 1.4 2.0 2.0 33.9 2934 610 0.387 30 165 160 18.18 8.13 5.75 1000/D
4x70 sm 1.4 2.0 2.1 38.7 4148 697 0.268 30 205 200 25.46 11.38 8.05 1000/D
4x95 sm 1.6 2.0 2.3 43.9 5489 790 0.193 30 245 245 34.55 15.45 10.93 1000/D
4x120 sm 1.6 2.5 2.4 48.2 7163 868 0.153 30 285 285 43.64 19.52 13.80 1000/D
4x150 sm 1.8 2.5 2.6 52.5 8637 945 0.124 20 315 325 54.45 24.40 17.25 500/D
4x185 sm 2.0 2.5 2.8 57.2 10354 1,030 0.0991 20 355 370 67.28 30.09 21.28 500/D
4x240 sm 2.2 2.5 3.0 64.3 13347 1,157 0.0754 20 415 435 87.28 39.03 27.60 250/D
4x300 sm 2.4 2.5 3.2 72.5 16702 1,305 0.0601 20 465 500 109.10 48.79 34.50 250/D
22 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized round steel wires with a counter helix
Annealed plain copper round solid or round circular stranded layer of galvanized steel tape.
according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : and/or special flame retardant, PVC sheath can be provided on
IEC 60502-1 request.
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Round of outer Diameter of Cable bending
at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation Steel sheath radius delivery
section Wire Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) Diameter (nom) (approx) (approx) Max Min second second second
(nom)
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
5x1.5 re 0.8 0.9 1.8 16 484 288 12.1 50 24 18 0.55 0.24 0.17 1000/D
5x1.5 rm 0.8 0.9 1.8 16.5 509 297 12.1 50 24 18 0.55 0.24 0.17 1000/D
5x2.5 re 0.8 0.9 1.8 17.7 647 319 7.41 50 32 25 0.91 0.41 0.29 1000/D
5x2.5 rm 0.8 1.25 1.8 18.5 687 333 7.41 50 32 25 0.91 0.41 0.29 1000/D
5x4 re 1.0 1.25 1.8 20 839 360 4.61 50 41 34 1.45 0.65 0.46 1000/D
5x4 rm 1.0 1.25 1.8 21 897 378 4.61 50 41 34 1.45 0.65 0.46 1000/D
5x6 re 1.0 1.25 1.8 21.4 996 385 3.08 50 52 44 2.18 0.98 0.69 1000/D
5x6 rm 1.0 1.25 1.8 22.5 1069 405 3.08 50 52 44 2.18 0.98 0.69 1000/D
5x10 rm 1.0 1.6 1.8 25.7 1527 463 1.83 50 69 60 3.64 1.63 1.15 1000/D
5x16 rm 1.0 1.6 1.8 28.3 1928 509 1.15 40 89 80 5.82 2.60 1.84 1000/D
5x25 rm 1.2 1.6 1.9 33.2 2641 598 0.727 40 116 105 9.09 4.15 2.96 1000/D
5x35 rm 1.2 2.0 2.0 37.4 3520 673 0.524 40 138 130 12.73 5.69 4.03 1000/D
5x50 rm 1A 2.0 2.1 43 4921 774 0.387 30 165 160 18.18 8.13 5.75 1000/D
[email protected] 23
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/SWA/PVC 0.6/1 kV (NYRGbY)
Specification :
SPLN 43-2 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions: 4. Armour :
1. Conductor: A layer of galvanized round steel wires with a counter helix
Annealed plain copper round solid or round circular stranded or layer of galvanized steel tape
according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : special flame retardant, PVC sheath can be provided on request.
IEC 60502-1
Applications:
Identification of core (SPLN) For general purpose power distribution in dry or wet location, best
Colour of insulation
suitable for direct burying in ground.
System - i System - 0
Note : [re] round solid conductor
Yellow/Green strip, Black with White number Black with White number
[rm] circular stranded conductor
(SNI IEC) : Black with White number
Packing : [D] Drum
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour
Constructions:
1. Conductor:
4. Armour :
Annealed plain copper round solid or round circular stranded or
A layer of galvanized round steel wires with a counter helix layer of
sector shape according to SPLN 41 - 1 ; IEC 60228
galvanized steel tape
2. Insulation:
5. Outer sheath:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/
IEC 60502-1
or special flame retardant, PVC sheath can be provided on request.
Identification of core (SPLN)
Applications:
Colour of insulation For general purpose power distribution in dry or wet location, best
System - i System - 0 suitable for direct burying in ground.
Yellow/Green strip, Black with White number Black with White number
Note : [re] round solid conductor
(SNI IEC) : Black with White number
[rm] circular stranded conductor
3. Inner Covering / filler:
Packing : [D] Drum
Extruded Polyvinyl Chloride [PVC], Black colour
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Round of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation Steel sheath radius delivery
section Wire Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) Diameter (nom) (approx) (approx] second second second
sq.mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
7x2.5 re 0.8 1.25 1.8 19.7 848 335 7.41 50 26 21 0.91 0.41 0.29 1000/D
7x2.5 rm 0.8 1.25 1.8 20.6 918 371 7.41 50 26 21 0.91 0.41 0.29 1000/D
8x2.5 re 0.8 1.25 1.8 21 928 378 7.41 50 23 18 0.91 0.41 0.29 1000/D
8x2.5 rm 0.8 1.25 1.8 21.8 1007 392 7.41 50 23 18 0.91 0.41 0.29 1000/D
10x2.5 re 0.8 1.6 1.8 24 1228 432 7.41 50 21 17 0.91 0.41 0.29 1000/D
10x2.5 rm 0.8 1.6 1.8 25.2 1332 454 7.41 50 21 17 0.91 0.41 0.29 1000/D
12x2.5 re 0.8 1.6 1.8 24.6 1317 443 7.41 50 20 16 0.91 0.41 0.29 1000/D
12x2.5 rm 0.8 1.6 1.8 25.7 1431 463 7.41 50 20 16 0.91 0.41 0.29 1000/D
14x2.5 re 0.8 1.6 1.8 25.4 1421 457 7.41 50 18 15 0.91 0.41 0.29 1000/D
14x2.5 rm 0.8 1.6 1.8 26.7 1548 481 7.41 50 18 15 0.91 0.41 0.29 1000/D
16x2.5 re 0.8 1.6 1.8 26.9 1561 484 7.41 50 17 14 0.91 0.41 0.29 1000/D
16x2.5 rm 0.8 1.6 1.8 27.7 1671 499 7.41 50 17 14 0.91 0.41 0.29 1000/D
19x2.5 re 0.8 1.6 1.8 27.5 1675 495 7.41 50 17 13 0.91 0.41 0.29 1000/D
19x2.5 rm 0.8 1.6 1.8 28.9 1833 520 7.41 50 17 13 0.91 0.41 0.29 1000/D
21x2.5 re 0.8 1.6 1.8 28.6 1800 515 7.41 50 16 12 0.91 0.41 0.29 1000/D
21x2.5 rm 0.8 1.6 1.8 30.2 1973 544 7.41 50 16 12 0.91 0.41 0.29 1000/D
24x2.5 re 0.8 1.6 1.9 30.4 1980 547 7.41 50 15 11 0.91 0.41 0.29 1000/D
24x2.5 rm 0.8 1.6 1.9 31.9 2173 574 7.41 50 15 11 0.91 0.41 0.29 1000/D
30x2.5 re 0.8 1.6 1.9 32.5 2280 585 7.41 50 14 11 0.91 0.41 0.29 1000/D
30x2.5 rm 0.8 2.0 1.9 35.5 2823 639 7.41 50 14 11 0.91 0.41 0.29 1000/D
40x2.5 re 0.8 2.0 2.1 37.3 3167 671 7.41 50 14 11 0.91 0.41 0.29 1000/D
40x2.5 rm 0.8 2.0 2.1 39.5 3389 711 7.41 50 14 11 0.91 0.41 0.29 1000/D
52x2.5 re 0.8 2.0 2.2 41.6 3704 749 7.41 50 14 11 0.91 0.41 0.29 1000/D
52x2.5 rm 0.8 2.0 2.2 43.2 4002 778 7.41 50 14 11 0.91 0.41 0.29 1000/D
61x2.5 re 0.8 2.0 2.3 43.9 4121 790 7.41 50 14 11 0.91 0.41 0.29 1000/D
61x2.5 rm 0.8 2.5 2.3 46.3 4970 833 7.41 50 14 11 0.91 0.41 0.29 1000/D
[email protected] 25
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification : SNI IEC 60502-1: 2009
2. Insulation: Applications:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : For indoor installations, in power and switching stations. As un-
IEC 60502-1 derground cable, for difficult installation where the low weight is
particularly
Identification of core : advantageous.
(SNI IEC) : Light Blue, Brown Note : [re] round solid conductor
[rm] circular stranded conductor
3. Inner sheath: Polyvinyl Chloride [PVC], Black colour
Packing : [D] Drum
4. Shield: Hellically copper tape
No. of Thickness Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of of of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation Copper sheath radius delivery
section tape Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) screened (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
2x1.5 re 0.8 0.1 1.8 12.1 218 218 12.1 50 27 21 0.55 0.24 0.17 1000/D
2x1.5 rm 0.8 0.1 1.8 12A 231 223 12.1 50 27 21 0.55 0.24 0.17 1000/D
2x2.5 re 0.8 0.1 1.8 12.8 263 230 7.41 50 36 29 0.91 0.41 0.29 1000/D
2x2.5 rm 0.8 0.1 1.8 13.4 280 241 7.41 50 36 29 0.91 0.41 0.29 1000/D
2x4 re 1.0 0.1 1.8 14.5 348 261 4.61 50 47 38 1.45 0.65 0.46 1000/D
2x4 rm 1.0 0.1 1.8 15.2 369 274 4.61 50 47 38 1.45 0.65 0.46 1000/D
2x6 re 1.0 0.1 1.8 16.5 417 297 3.08 50 59 48 2.18 0.98 0.69 1000/D
2x6 rm 1.0 0.1 1.8 18.1 445 326 3.08 50 59 48 2.18 0.98 0.69 1000/D
2x10 rm 1.0 0.1 1.8 20.2 582 364 1.83 50 78 66 3.64 1.63 1.15 1000/D
2x16 rm 1.0 0.1 1.8 23.6 771 425 1.15 40 102 90 5.82 2.60 1.84 1000/D
2x25 rm 1.2 0.1 1.8 25.8 1095 464 0.727 40 134 120 9.09 4.07 2.88 1000/D
2x35 rm 1.2 0.1 1.8 29.2 1368 526 0.524 40 180 150 12.73 5.69 4.03 1000/D
2x50 rm 1.4 0.1 1.9 32.7 1748 589 0.387 30 210 180 18.18 8.13 5.75 1000/D
2x70 rm 1.4 0.1 2.0 38.4 2336 691 0.268 30 260 230 25.46 11.38 8.05 1000/D
2x95 rm 1.6 0.1 2.2 41.6 3159 749 0.193 30 315 280 34.55 15.45 10.93 1000/D
2x120 rm 1.6 0.1 2.3 45.5 3807 819 0.153 30 320 320 43.64 19.52 13.80 1000/D
2x150 rm 1.8 0.1 2.4 50.6 4647 911 0.124 20 355 375 54.55 24.40 17.25 500/D
2x185 rm 2.0 0.1 2.6 53.5 5756 909 0.0991 20 409 430 67.28 30.09 21.28 500/D
2x240 rm 2.2 0.1 2.8 57.3 7366 1,031 0.0754 20 472 510 87.28 39.03 27.60 250/D
2x300 rm 2.4 0.1 3.0 63.3 9117 1,139 0.0601 20 525 590 109.10 48.79 34.50 250/D
26 www.kabelindo.co.id
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60902-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
sector shape according to SPLN 41 - 1 ; IEC 60228 Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
2. Insulation: request.
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
For indoor installations, in power and switching stations.
Identification of core : As underground cable, for difficult installation where the low
weight is particularly advantageous.
(SNI IEC) : Yellow/Green Strip, Light Blue, Brown
Note: (re) round solid conductor
3. Inner Covering / filler: (rm) circular stranded conductor
Extruded Polyvinyl Chloride [PVC], Black colour (sm) sector shaped conductor
No. of Thickness Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of of Copper of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation tape sheath radius delivery
section screened Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A m
3x1.5 re 0.8 0.1 1.8 12.4 246 223 12.1 50 24 18 0.55 0.24 0.17 1000/D
3x1.5 rrn 0.8 0.1 1.8 12.9 262 232 12.1 50 24 18 0.55 0.24 0.17 1000/D
3x2.5 re 0.8 0.1 1.8 13.3 296 239 7.41 50 32 25 0.91 0.41 0.29 1000/D
3x2.5 rm 0.8 0.1 1.8 13.9 323 250 7.41 50 32 25 0.91 0.41 0.29 1000/D
3x4 re 1.0 0.1 1.8 15.3 398 275 4.61 50 41 34 1.45 0.65 0A6 1000/D
3x4 rm 1.0 0.1 1.8 15.8 432 284 4.61 50 41 34 1.45 0.65 0.46 1000/D
3x6 re 1.0 0.1 1.8 16.4 492 295 3.08 50 52 44 2.18 0.98 0.69 1000/D
3x6 rm 1.0 0.1 1.8 17.2 524 310 3.08 50 52 44 2.18 0.98 0.69 1000/D
3x10 rm 1.0 0.1 1.8 19.1 698 344 1.83 50 69 60 3.64 1.63 1.15 1000/D
3x16 rm 1.0 0.1 1.8 21.4 940 385 1.15 40 89 80 5.82 2.60 1.84 1000/D
3x25 rm 1.2 0.1 1.8 24.7 1359 445 0.727 40 116 105 9.09 4.07 2.88 1000/D
3x35 rm 1.2 0.1 1.8 27.5 1720 495 0.524 40 138 130 12.73 5.69 4.03 1000/D
3x50 sm 1.4 0.1 1.9 28.7 2018 517 0.387 30 165 160 18.18 8.13 5.75 1000/D
3x70 sm 1A 0.1 2.0 30.2 2671 544 0.268 30 205 200 25A6 11.38 8.05 1000/D
3x95 sm 1.6 0.1 2.2 34.6 3641 623 0.193 30 245 245 34.55 15.45 10.93 1000/D
3x120 sm 1.6 0.1 2.3 37.8 4478 680 0.153 30 285 285 43.64 19.52 13.80 1000/D
3x150 sm 1.8 0.1 2.4 41.3 5486 743 0.124 20 315 325 54.55 24.40 17.25 500/D
3x185 sm 2.0 0.1 2.6 45.6 6693 821 0.0991 20 355 370 67.28 30.09 21.28 500/D
3x240 sm 2.2 0.1 2.8 51.2 8727 922 0.0754 20 415 435 87.28 39.03 27.60 250/D
3x300 sm 2.4 0.1 3.0 57.2 10869 1,030 0.0601 20 465 500 109.10 48.79 34.50 250/D
[email protected] 27
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1: 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
sector shape according to SPLN 41 - 1 ; IEC 60228 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
2. Insulation: request
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
For indoor installations, in power and switching stations. As
Identification of core: underground cable, for difficult installation where the low weight
is particularly advantageous.
(SNI IEC) :
Yellow/Green Strip, Light Blue, Black, Brown Note : [re] round solid conductor
[rm] circular stranded conductor
3.Inner covering / filler: [sm) sector shaped conductor
Extruded Polyvinyl Chloride (PVC), Black colour
Packing : [D] Drum
4. Shield: Hellically copper tape
No. of Thickness Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of of Copper of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation tape sheath radius delivery
section screened Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
4x1.5 re 0.8 0.1 1.8 13.1 281 236 12.1 50 24 18 0.55 0.24 0.17 1000/D
4x1.5 rm 0.8 0.1 1.8 13.4 296 241 12.1 50 24 18 0.55 024 0.17 1000/D
4x2.5 re 0.8 0.1 1.8 14.2 348 256 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x2.5 rm 0.8 0.1 1.8 14.8 373 266 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x4 re 1.0 0.1 1.8 16.3 470 293 4.61 50 41 34 1.45 0.65 0.46 1000/D
4x4 rm 1.0 0.1 1.8 17.1 509 308 4.61 50 41 34 1.45 0.65 0.46 1000/D
4x6 re 1.0 0.1 1.8 17.6 585 317 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x6 rm 1.0 0.1 1.8 18.5 627 333 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x10 rm 1.0 0.1 1.8 20.4 847 367 1.83 50 69 60 3.64 1.63 1.15 1000/D
4x16 rm 1.0 0.1 1.8 23.1 1158 416 1.15 40 89 80 5.82 2.60 1.84 1000/D
4x25 rm 1.2 0.1 1.8 27.2 1683 490 0.727 40 116 105 9.09 4.07 2.88 1000/D
4x35 rm 1.2 0.1 1.9 30.2 2452 544 0.524 40 138 130 12.73 5.69 4.03 1000/D
4x50 sm 1.4 0.1 2.0 31.8 2640 572 0.387 30 165 160 18.18 8.13 5.75 1000/D
4x70 sm 1.4 0.1 2.1 35.7 3519 643 0.268 30 205 200 25.46 11.38 8.05 1000/D
4x95 sm 1.6 0.1 2.3 40.8 4717 734 0.193 30 245 245 34.55 15.45 10.93 1000/D
4x120 sm 1.6 0.1 2.4 44.6 5879 803 0.153 30 285 285 43.64 19.52 13.80 1000/D
4x150 sm 1.8 0.1 2.6 48.1 7135 866 0.124 20 315 325 54.55 24.40 17.25 500/D
4x185 sm 2.0 0.1 2.8 53.8 8847 968 0.0991 20 355 370 67.28 30.09 21.28 500/D
4x240 sm 2.2 0.1 3.0 60.4 11363 1.087 0.0754 20 415 435 87.28 39.03 27.60 250/D
4x300 sm 2.4 0.1 3.2 66.8 13858 1.202 0.0601 20 465 500 109.10 48.79 34.50 250/D
28 www.kabelindo.co.id
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Power Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
according to SPLN 41 - 1 ; IEC 60228 Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/or special flame retardant, PVC sheath can be provided on
2. Insulation: request.
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
For indoor installations, in power and switching stations. As un-
Identification of core : derground cable, for difficult installation where the low weight is
particularly advantageous.
(SNI IEC) :
Yellow/Green strip, Light Blue, Black, Brown, Grey Note : (re) round solid conductor
(rm) circular stranded conductor
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour Packing : [D] Drum
No. of Thickness Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of of Copper of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation tape sheath radius delivery
section screened Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
5x1.5 re 0.8 0.1 1.8 14.2 327 256 12.1 50 24 18 0.55 0.24 0.17 1000/D
5x1.5 rm 0.8 0.1 1.8 14.7 345 265 12.1 50 24 18 0.55 0.24 0.17 1000/D
5x2.5 re 0.8 0.1 1.8 15.5 408 279 7.41 50 32 25 0.91 0.41 0.29 1000/D
5x2.5 rm 0.8 0.1 1.8 16.2 435 292 7.41 50 32 25 0.91 0.41 0.29 1000/D
5x4 re 1.0 0.1 1.8 17.4 564 313 4.61 50 41 34 1.45 0.65 0A6 1000/D
5x4 rm 1.0 0.1 1.8 18.5 606 333 4.61 50 41 34 1.45 0.65 0.46 1000/D
5x6 re 1.0 0.1 1.8 18.9 708 340 3.08 50 52 44 2.18 0.98 0.69 1000/D
5x6 rm 1.0 0.1 1.8 19.8 761 356 3.08 50 52 44 2.18 0.98 0.69 1000/D
5x10 rm 1.0 0.1 1.8 22.4 1036 403 1.83 50 69 60 3.64 1.63 1.15 1000/D
5x16 rm 1.0 0.1 1.8 25.2 1415 454 1.15 40 89 80 5.82 2.60 1.84 1000/D
5x25 rm 1.2 0.1 1.8 29.7 2079 535 0.727 40 116 105 9.09 4.07 2.88 1000/D
5x35 rm 1.2 0.1 1.8 32.6 2685 587 0.524 40 138 130 12.73 5.69 4.03 1000/D
5x50 rm 14 0.1 1.9 37.8 3497 680 0.387 30 165 160 18.18 8.13 5.75 1000/D
[email protected] 29
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Control Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1: 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
according to SPLN 41 - 1; IEC 60228 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
2. Insulation: request
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
For indoor installations, in power and switching stations. As un-
Identification of core: derground cable, for difficult installation where the low weight is
Black with White printed number particularly
advantageous.
3.Inner covering /filler:
Extruded Polyvinyl Chloride (PVC), Black colour Note : [re] round solid conductor
[rm] circular stranded conductor
4. Shield: Hellically copper tape
Packing : [D] Drum
No. of Thickness Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of of Copper of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation tape sheath radius delivery
section screened Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
7x1.5 re 0.8 0.1 1.8 14.9 357 268 12.1 50 17 13 0.55 0.24 0.17 1000/D
7x1.5 rm 0.8 0.1 1.8 15.5 372 279 12.1 50 17 13 0.55 0.24 0.17 1000/D
8x1.5 re 0.8 0.1 1.8 16.1 394 290 12.1 50 16 12 0.55 0.24 0.17 1000/D
8x1.5 rm 0.8 0.1 1.8 16.5 418 297 12.1 50 16 12 0.55 0.24 0.17 1000/D
10x1.5 re 0.8 0.1 1.8 18.2 475 328 12.1 50 15 11 0.55 0.24 0.17 1000/D
10x1.5 rm 0.8 0.1 1.8 18.6 496 335 12.1 50 15 11 0.55 0.24 0.17 1000/D
12x1.5 re 0.8 0.1 1.8 18.7 518 337 12.1 50 14 11 0.55 0.24 0.17 1000/D
12x1.5 rm 0.8 0.1 1.8 19.2 545 346 12.1 50 14 11 0.55 0.24 0.17 1000/D
14x1.5 re 0.8 0.1 1.8 19.4 586 349 12.1 50 13 10 0.55 0.24 0.17 1000/D
14x1.5 rm 0.8 0.1 1.8 20.2 613 364 12.1 50 13 10 0.55 0.24 0.17 1000/D
16x1.5 re 0.8 0.1 1.8 20.4 642 367 12.1 50 12 10 0.55 0.24 0.17 1000/D
16x1.5 rm 0.8 0.1 1.8 20.8 675 374 12.1 50 12 10 0.55 0.24 0.17 1000/D
19x1.5 re 0.8 0.1 1.8 21.2 718 382 12.1 50 12 9 0.55 0.24 0.17 1000/D
19x1.5 rm 0.8 0.1 1.8 21.8 757 392 12.1 50 12 9 0.55 0.24 0.17 1000/D
21x1.5 re 0.8 0.1 1.8 22.2 778 400 12.1 50 11 9 0.55 0.24 0.17 1000/D
21x1.5 rm 0.8 0.1 1.8 22.8 820 410 12.1 50 11 9 0.55 0.24 0.17 1000/D
24x1.5 re 0.8 0.1 1.8 23.8 872 428 12.1 50 11 8 0.55 0.24 0.17 1000/D
24x1.5 rm 0.8 0.1 1.8 25 928 450 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 re 0.8 0.1 1.8 25.3 1026 455 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 rm 0.8 0.1 1.8 26.7 1085 481 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 re 0.8 0.1 1.8 27.6 1288 497 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 rm 0.8 0.1 1.8 29A 1356 529 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 re 0.8 0.1 1.9 31.8 1656 572 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 rm 0.8 0.1 1.9 33.4 1752 601 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 re 0.8 0.1 2.0 33.7 1893 607 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 rm 0.8 0.1 2.0 35.2 1990 634 12.1 50 11 8 0.55 0.24 0.17 1000/D
30 www.kabelindo.co.id
Copper Conductor PVC Insulated, Copper tape Screened & PVC Sheathed Control Cable
Cu/PVC/CTS/PVC 0.6/1 kV (NYSY)
Specification :
SNI IEC 60502-1:2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
according to SPLN 41 - 1; IEC 60228 Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
and/orspecial flame retardant, PVC sheath can be provided on
2. Insulation: request.
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
For indoor installations, in power and switching stations.
Identification of core : As underground cable, for difficult installation where the low
Black with White printed number weight is particularly advantageous.
No. of Thickness Thickness Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of of Copper of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation tape sheath radius delivery
section screened Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
7x2.5 re 0.8 0.1 1.8 15.8 458 284 7.41 50 23 18 0.91 0.41 0.29 1000/D
7x2.5 rm 0.8 0.1 1.8 16.6 486 299 741 50 23 18 0.91 0.41 0.29 1000/D
8x2.5 re 0.8 0.1 1.8 17.1 509 308 7.41 50 21 17 0.91 0.41 0.29 1000/D
8x2.5 rm 0.8 0.1 1.8 18.3 545 329 7.41 50 21 17 0.91 0.41 0.29 1000/D
10x2.5 re 0.8 0.1 1.8 19.3 617 347 7.41 50 20 16 0.91 0.41 0.29 1000/D
10x2.5 rrn 0.8 0.1 1.8 20.5 656 369 7.41 50 20 16 0.91 0.41 0.29 1000/D
12x2.5 re 0.8 0.1 1.8 20.7 682 373 7.41 50 18 15 0.91 0.41 0.29 1000/D
12x2.5 rm 0.8 0.1 1.8 21.5 432 387 7.41 50 18 15 0.91 0.41 0.29 1000/D
14x2.5 re 0.8 0.1 1.8 21.8 775 392 7.41 50 17 14 0.91 0.41 0.29 1000/D
14x2.5 rm 0.8 0.1 1.8 22.5 826 405 7.41 50 17 14 0.91 0.41 0.29 1000/D
16x2.5 re 0.8 0.1 1.8 22.6 854 407 7.41 50 17 13 0.91 0.41 0.29 1000/D
16x2.5 rm 0.8 0.1 1.8 23.4 918 421 741 50 17 13 0.91 0.41 0.29 1000/D
19x2.5 re 0.8 0.1 1.8 23.6 962 425 7.41 50 16 13 0.91 0.41 0.29 1000/D
19x2.5 rm 0.8 0.1 1.8 24.8 1027 446 7.41 50 16 13 0.91 0.41 0.29 1000/D
21x2.5 re 0.8 0.1 1.8 25.1 1055 452 7.41 50 15 12 0.91 0.41 0.29 1000/D
21x2.5 rrn 0.8 0.1 1.8 25.8 1136 464 7.41 50 15 12 0.91 0.41 0.29 1000/D
24x2.5 re 0.8 0.1 1.8 26.2 1210 472 7.41 50 14 11 0.91 0.41 0.29 1000/D
24x2.5 rm 0.8 0.1 1.8 26.8 1292 482 7.41 50 14 11 0.91 0.41 0.29 1000/D
30x2.5 re 0.8 0.1 1.9 28.3 1426 509 7.41 50 14 11 0.91 0.41 0.29 1000/D
30x2.5 rm 0.8 0.1 1.9 30.2 1535 544 7.41 50 14 11 0.91 0.41 0.29 1000/D
40x2 5 re 0.8 0.1 2.0 31.7 1840 571 7.41 50 14 11 0.91 0.41 0.29 1000/D
40x2.5 rm 0.8 0.1 2.0 33.5 1973 603 7.41 50 14 11 0.91 0.41 0.29 1000/D
52)(2.5 re 0.8 0.1 2.1 37.4 2358 673 7.41 50 14 11 0.91 0.41 0.29 1000/D
52x2.5 rm 0.8 0.1 2.1 38.6 2534 695 7.41 50 14 11 0.91 0.41 0.29 1000/D
61x2.5 re 0.8 0.1 2.1 40.6 2701 731 7.41 50 14 11 0.91 0.41 0.29 1000/D
61x2.5 rrn 0.8 0.1 2.1 41.4 2895 745 7.41 50 14 11 0.91 0.41 0.29 1000/D
[email protected] 31
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification:
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
according to SPLN 41 - 1 ; IEC 60228 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
2. Insulation: request
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
Indoor, in ducts, in the open, underground, if mechanical damage
Identification of core: (SPLN) is not expected
Light Blue and Brown Light Blue and Red or Light Blue and
Yellow or Light Blue and Black Note : [re] round solid conductor
[rm] circular stranded conductor
(SNI IEC) :
Light Blue and Brown Packing : [D] Drum
3.Inner sheat:
Polyvinyl Chloride (PVC), Black colour
4. Screen:
Annealed copper wire with transverse helix of Annealed copper tape
No. of Thickness Cross Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of section of of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulationconcentric sheath radius delivery
section shield Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
2x1.5 re/1.5 0.8 1.5 1.8 13.5 230 243 12.1 50 27 21 0.55 0.24 0.17 1000/D
2x1.5 rm/1.5 0.8 1.5 1.8 13.9 242 250 12.1 50 27 21 0.55 0.24 0.17 1000/D
2x2.5 re/2.5 0.8 2.5 1.8 14.5 281 261 7.41 50 36 29 0.91 0.41 0.29 1000/D
2x2.5 rm/2.5 0.8 2.5 1.8 16.2 290 292 7.41 50 36 29 0.91 0.41 0.29 1000/D
2x4 re/4 1.0 4 1.8 16.8 370 302 4.61 50 47 38 1.45 0.65 0.46 1000/D
2x4 rm/4 1.0 4 1.8 17.2 395 310 4.61 50 47 38 1.45 0.65 0.46 1000/D
2x6 re/6 1.0 6 1.8 17.8 454 320 3.08 50 59 48 2.18 0.98 0.69 1000/D
2x6 rm/6 1.0 6 1.8 18.1 485 326 3.08 50 59 48 2.18 0.98 0.69 1000/D
2x10 rm/10 1.0 10 1.8 20.2 658 364 1.83 50 78 66 3.64 1.63 1.15 1000/D
2x16 rm/16 1.0 16 1.8 22 891 396 1.15 40 102 90 5.82 2.60 1.84 1000/D
2x25 rm/16 1.2 16 1.8 25.6 1207 461 0.727 40 134 120 9.09 4.07 2.88 1000/D
2x35 rm/16 1.2 16 1.8 27.8 1476 500 0.524 40 180 150 12.73 5.69 4.03 1000/D
2x50 rm/25 1.4 25 1.9 31.3 1928 563 0.387 30 210 180 18.18 8.13 5.75 1000/D
2x70 rm/35 14 35 2.0 35.8 2605 644 0.268 30 260 230 25.46 11.38 8.05 1000/D
2x95 rm/50 1.6 50 2.2 40.4 3557 727 0.193 30 315 280 34.55 15.45 10.93 1000/D
2x120 rm/70 1.6 70 2.3 43.6 4376 785 0.153 30 320 320 43.64 19.52 13.80 1000/D
2x150 rm/70 1.8 70 2.4 48.5 5208 873 0.124 20 355 375 54.55 24.40 17.25 500/D
2x185 rm/95 2.0 95 2.6 53.8 6546 968 0.0991 20 409 430 67.28 30.09 21.28 500/D
2x240 rm/120 2.2 120 2.8 60.6 8368 1,091 0.0754 20 472 510 87.28 39.03 27.60 250/D
2x300 rm/150 2.4 150 3.0 67.5 10385 1,215 0.0601 20 525 590 109.10 48.79 34.50 250/D
32 www.kabelindo.co.id
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification :
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
No. of Thickness Cross Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of section of of outer Diameter of Cable bending Capacity at 30°C Current Capacity at Standard
and cross Insulation concentric sheath radius delivery
section shield Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
area (nom) (nom) (approx) (approx] Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm. A A kA kA kA m
3x1.5 re/1.5 0.8 1.5 1.8 14.1 260 253 12.1 50 24 18 0.55 0.24 0.17 1000/D
3x1.5 rm/1.5 0.8 1.5 1.8 144 271 259 12.1 50 24 18 0.55 0.24 0.17 1000/D
3x2.5 re/2.5 0.8 2.5 1.8 14.9 322 268 7.41 50 32 25 0.91 0.41 0.29 1000/D
3x2.5 rm/2.5 0.8 2.5 1.8 15.5 339 279 7.41 50 32 25 0.91 0.41 0.29 1000/D
3x4 re/4 1.0 4 1.8 16.9 427 304 4.61 50 41 34 145 0.65 0.46 1000/D
3x4 rm/4 1.0 4 1.8 17.5 456 315 4.61 50 41 34 1.45 0.65 0.46 1000/D
3x6 re/6 1.0 6 1.8 18.2 535 328 3.08 50 52 44 2.18 0.98 0.69 1000/D
3x6 rm/6 1.0 6 1.8 19.1 568 344 3.08 50 52 44 2.18 0.98 0.69 1000/D
3x10 rm/10 1.0 10 1.8 21.3 787 383 1.83 50 69 60 3.64 1.63 1.15 1000/D
3x16 rm/16 1.0 16 1.8 23.2 1068 418 1.15 40 89 80 5.82 2.60 1.84 1000/D
3x25 rm/16 1.2 16 1.8 26.8 1476 482 0.727 40 116 105 9.09 4.07 2.88 1000/D
3x35 rm/16 1.2 16 1.8 29.5 1438 531 0.524 40 138 130 12.73 5.69 4.03 1000/D
3x50 sm/25 1.4 25 1.9 29.7 2216 535 0.387 30 165 160 18.18 8.13 5.75 1000/D
3x70 sm/35 1.4 35 2.0 324 2985 583 0.268 30 205 200 25.46 11.38 8.05 1000/D
3x95 sm/50 1.6 50 2.2 36.6 4065 659 0.193 30 245 245 34.55 15.45 10.93 1000/D
3x120 sm/70 1.6 70 2.3 40.2 5073 724 0.153 30 285 285 43.64 19.52 13.80 1000/D
3x150 sm/70 1.8 70 24 43.7 6082 787 0.124 20 315 325 54.45 24.40 17.25 500/D
3x185 sm/95 2.0 95 2.6 494 7516 889 0.0991 20 355 370 67.28 30.09 21.28 500/D
3x240 sm/120 2.2 120 2.8 54.8 9768 986 0.0754 20 415 435 87.28 39.03 27.60 250/D
3x300 sm/150 2.4 150 3.0 61.3 12186 1,103 0.0601 20 465 500 109.10 48.79 34.50 250/D
[email protected] 33
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification :
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
sector shape according to SPLN 41 - 1 ; IEC 60228 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
2. Insulation: request
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
Indoor, in ducts, in the open, underground, if mechanical damage
Identification of core: (SPLN) is not expected
Light Blue, Red,Yellow, Black
Note : [re] round solid conductor
(SNI IEC) : [rm] circular stranded conductor
Yellow/Green strip, Light Blue, Black, Brown (sm) sector shaped conductor
4. Shield:
Annealed copper wire with transverse helix of Annealed copper tape
No. of cores Thickness Cross Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
and cross of section of of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
section area Insulation concentric sheath radius delivery
shield Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
4x1.5 re/1.5 0.8 1.5 1.8 14.7 236 265 12.1 50 24 18 0.55 0.24 0.17 1000/D
4x1.5 rm/1.5 0.8 1.5 1.8 15.2 249 274 12.1 50 24 18 0.55 0.24 0.17 1000/D
4x2.5 re/2.5 0.8 2.5 1.8 15.8 303 284 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x2.5 rm/2.5 0.8 2.5 1.8 16.4 324 295 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x4 re/4 1.0 4 1.8 18.1 428 326 4.61 50 41 34 1.45 0.65 0.46 1000/D
4x4 re/4 1.0 4 1.8 18.9 457 340 4.61 50 41 34 145 0.65 0.46 1000/D
4x6 re/6 1.0 6 1.8 19.3 546 347 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x6 rm/6 1.0 6 1.8 20.2 585 364 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x10 rm/10 1.0 10 1.8 22.7 817 409 1.83 50 69 60 3.64 1.63 1.15 1000/D
4x16 rm/16 1.0 16 1.8 25.3 1155 455 1.15 40 89 80 5.82 2.60 1.84 1000/D
4x25 rm/16 1.2 16 1.8 29.2 1648 526 0.727 40 116 105 9.09 4.07 2.88 1000/D
4x35 rm/16 1.2 16 1.8 31.8 2095 572 0.524 40 138 130 12.73 5.69 4.03 1000/D
4x50 sm/25 1.4 25 2.0 33.7 2664 607 0.387 30 165 160 18.18 8.13 5.75 1000/D
4x70 sm/35 1.4 35 2.1 40.2 3573 724 0.268 30 205 200 25.46 11.38 8.05 1000/D
4x95 sm/50 1.6 50 2.3 42.6 4880 767 0.193 30 245 245 34.55 1545 10.93 1000/D
4x120 sm/70 1.6 70 2.4 47.4 6153 853 0.153 30 285 285 43.64 19.52 13.80 1000/D
4x150 sm/70 1.8 70 2.6 50.6 7377 911 0.124 20 315 325 54.45 24.40 17.25 500/D
4x185 sm/95 2.0 95 2.8 57.5 9195 1 ,035 0.0991 20 355 370 67.28 30.09 21.28 500/D
4x240 sm/120 2.2 120 3.0 63.8 11865 1,148 0.0754 20 415 435 87.28 39.03 27.60 250/D
4x300 sm/150 2.4 150 3.2 71.6 14420 1,289 0.0601 20 465 500 109.10 48.79 34.50 250/D
34 www.kabelindo.co.id
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Control Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification :
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228 5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite
2. Insulation: and/or special flame retardant, PVC sheath can be provided on
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : request.
IEC 60502-1
Applications:
Identification of core : For indoor installations, in power and switching stations.
Black with White printed number As underground cable, for difficult installation where the low
weight is particularly advantageous.
3. Inner Covering / filler:
Extruded Polyvinyl Chloride [PVC], Black colour Note: (re) round solid conductor
(rm) circular stranded conductor
4. Shield:
Annealed copper wire with transverse helix of Annealed copper tape Packing : [D] Drum
Thickness Cross Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
No. of cores of section of of outer Diameter of Cable Current Capacity at
bending at 20°C Capacity at 30°C Standard
and cross Insulation concentric sheath
radius delivery
section area shield Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
5x1.5 re/2.5 0.8 2.5 1.8 16.4 361 295 12.1 50 19 15 0.55 0.24 0.17 1000/D
5x1.5 rm/2.5 0.8 2.5 1.8 16.6 372 299 12.1 50 19 15 0.55 0.24 0.17 1000/D
7x1.5 re/2.5 0.8 2.5 1.8 17 407 306 12.1 50 17 13 0.55 0.24 0.17 1000/D
7x1.5 rm/2.5 0.8 2.5 1.8 17.6 441 317 12.1 50 17 13 0.55 0.24 0.17 1000/D
8x1.5 re/2.5 0.8 2.5 1.8 18 445 324 12.1 50 16 12 0.55 0.24 0.17 1000/D
8x1.5 rm/2.5 0.8 2.5 1.8 18.7 485 337 12.1 50 16 12 0.55 0.24 0.17 1000/D
10x1.5 re/2.5 0.8 2.5 1.8 20.1 542 362 12.1 50 15 11 0.55 0.24 0.17 1000/D
10x1.5 rm/2.5 0.8 2.5 1.8 20.9 592 376 12.1 50 15 11 0.55 0.24 0.17 1000/D
12x1.5 re/2.5 0.8 2.5 1.8 20.6 594 371 12.1 50 14 11 0.55 0.24 0.17 1000/D
12x1.5 rm/2.5 0.8 2.5 1.8 21.5 649 387 12.1 50 14 11 0.55 0.24 0.17 1000/D
14x1.5 re/2.5 0.8 2.5 1.8 21.4 647 385 12.1 50 13 10 0.55 0.24 0.17 1000/D
14x1.5 rm/2.5 0.8 2.5 1.8 22.3 710 401 12.1 50 13 10 0.55 0.24 0.17 1000/D
16x1.5 re/4 0.8 4 1.8 22.7 721 409 12.1 50 12 10 0.55 0.24 0.17 1000/D
16x1.5 rm/4 0.8 4 1.8 23.3 775 419 12.1 50 12 10 0.55 0.24 0.17 1000/D
19x1.5 re/4 0.8 4 1.8 23.2 784 418 12.1 50 12 9 0.55 0.24 0.17 1000/D
19x1.5 rm/4 0.8 4 1.8 24.3 865 437 12.1 50 12 9 0.55 0.24 0.17 1000/D
21x1.5 re/6 0.8 6 1.8 24.2 866 436 12.1 50 11 9 0.55 0.24 0.17 1000/D
21x1.5 rm/6 0.8 6 1.8 25.3 955 455 12.1 50 11 9 0.55 0.24 0.17 1000/D
24x1.5 re/6 0.8 6 1.8 25.8 958 464 12.1 50 11 8 0.55 0.24 0.17 1000/D
24x1.5 rm/6 0.8 6 1.8 27 1058 486 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 re/6 0.8 6 1.8 27.7 1125 499 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 rm/6 0.8 6 1.8 29 1247 522 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 re/10 0.8 10 1.8 30.7 1417 553 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 rm/10 0.8 10 1.8 32.2 1576 580 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 re/10 0.8 10 1.9 34.8 1785 626 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 rm/10 0.8 10 1.9 36.5 1988 657 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 re/10 0.8 10 2.0 37 2025 666 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 rm/10 0.8 10 2.0 38.7 2259 697 12.1 50 11 8 0.55 0.24 0.17 1000/D
[email protected] 35
Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Control Cable
Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)
Specification :
SPLN 43-4 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite and/or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : special flame retardant. PVC sheath can be provided on request
IEC 60502-1
Applications:
For indoor installations, in power and switching stations.
Identification of core: (SPLN)
As underground cable, for difficult installation where the low weight is
Black with White printed number particularly advantageous.
No. of Thickness Cross Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of section of of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulationconcentric sheath radius delivery
section shield Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
5x2.5 re/2.5 0.8 2.5 1.8 17.5 432 315 7.41 50 26 21 0.91 0.41 0.29 1000/D
5x2.5 rm/2.5 0.8 2.5 1.8 17.8 453 320 7.41 50 26 21 0.91 0.41 0.29 1000/D
7x2.5 re/2.5 0.8 2.5 1.8 18.1 514 326 7.41 50 23 18 0.91 0.41 0.29 1000/D
7x2.5 rm/2.5 0.8 2.5 1.8 18.9 564 340 7.41 50 23 18 0.91 0.41 0.29 1000/D
8x2 5 re/2.5 0.8 2.5 1.8 19.3 565 347 7.41 50 21 17 0.91 0.41 0.29 1000/D
8x2.5 rm/2.5 0.8 2.5 1.8 20.2 620 364 7.41 50 21 17 0.91 0.41 0.29 1000/D
10x2.5 re/4 0.8 4 1.8 21.6 672 389 7.41 50 20 16 0.91 0.41 0.29 1000/D
10x2.5 rm/4 0.8 4 1.8 22.7 741 409 7.41 50 2D 16 0.91 0.41 0.29 1000/D
12x2.5 re/4 0.8 4 1.8 22.2 743 400 7.41 50 18 15 0.91 0.41 0.29 1000/D
12x2.5 rm/4 0.8 4 1.8 23.3 822 419 7.41 50 18 15 0.91 0.41 0.29 1000/D
14x2.5 re/6 0.8 6 1.8 23.1 818 416 7.41 50 17 14 0.91 0.41 0.29 1000/D
14x2.5 rm/6 0.8 6 1.8 24.3 907 437 7.41 50 17 14 0.91 0.41 0.29 1000/D
16x2.5 re/6 0.8 6 1.8 24.5 914 441 7.41 50 17 13 0.91 0.41 0.29 1000/D
16x2.5 rm/6 0.8 6 1.8 25.4 997 457 7.41 50 17 13 0.91 0.41 0.29 1000/D
19x2.5 re/6 0.8 6 1.8 25.2 1007 454 7.41 50 16 13 0.91 0.41 0.29 1000/D
19x2 5 rm/6 0.8 6 1.8 26.5 1122 477 7.41 50 16 13 0.91 0.41 0.29 1000/D
21x2.5 re/10 0.8 10 1.8 26.4 1153 475 7.41 50 15 12 0.91 0.41 0.29 1000/D
21x2.5 rm/10 0.8 10 1.8 27.8 1281 500 7.41 50 15 12 0.91 0.41 0.29 1000/D
24x2.5 re/10 0.8 10 1.8 28.1 1278 506 7.41 50 14 11 0.91 0.41 0.29 1000/D
24x2.5 rm/10 0.8 10 1.8 29.7 1338 535 7.41 50 14 11 0.91 0.41 0.29 1000/D
30x2.5 re/10 0.8 10 1.8 30.3 1510 545 7.41 50 14 11 0.91 0.41 0.29 1000/D
30x2.5 rm/10 0.8 10 1.8 32 1687 576 7.41 50 14 11 0.91 0.41 0.29 1000/D
40x2.5 re/10 0.8 10 1.9 34.1 1917 614 7.41 50 14 11 0.91 0.41 0.29 1000/D
40x2.5 rm/10 0.8 10 1.9 36.1 2145 650 7.41 50 14 11 0.91 0.41 0.29 1000/D
52x2.5 re/10 0.8 10 2.1 38.4 2402 691 7.41 50 14 11 0.91 0.41 0.29 1000/D
52x2.5 rm/10 0.8 10 2.1 40.7 2694 733 7.41 50 14 11 0.91 0.41 0.29 1000/D
61x2.5 re/10 0.8 10 2.1 40.5 2716 729 7.41 50 14 11 0.91 0.41 0.29 1000/D
61x2.5 rm/10 0.8 10 2.1 43 3053 774 7.41 50 14 11 0.91 0.41 0.29 1000/D
36 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Specification :
SPLN 43-3 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath:
IEC 60502-1 Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
special flame retardant, PVC sheath can be provided on request.
Identification of core: (SPLN)
Light Blue, Black Applications:
For installations as underground, outdoor, indoor in ducts and where
(SNI IEC) mechanical protection is required or for higher tensile stresses during
Light Blue, Brown installation and operation.
4. Armour
Two layers of galvanized steel tape helically applied Packing : [D] Drum
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Steel of outer Diameter of Cable bending Capacity at 30°C Current Capacity at Standard
and cross Insulation Tape sheath radius delivery
section thickness Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx) second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
2x6 re 1.0 0.3 1.8 16.7 557 301 3.08 50 59 48 2.18 0.98 0.69 1000/D
2x6 rm 1.0 0.3 1.8 17.5 587 315 3.08 50 59 48 2.18 0.98 0.69 1000/D
2x10 rm 1.0 0.3 1.8 19.4 709 349 1.83 50 78 66 3.64 1.63 1.15 1000/D
2x16 rm 1.0 0.3 1.8 21.3 894 383 1.15 40 102 90 5.82 2.60 1.84 1000/D
2x25 rm 1.2 0.3 1.8 24.8 1248 446 0.727 40 134 120 9.09 4.07 2.88 1000/D
2x35 rm 1.2 0.3 1.8 27.2 1555 490 0.524 40 160 150 12.73 5.69 4.03 1000/D
2x50 rm 1.4 0.3 1.8 30.3 1952 545 0.387 30 187 180 18.18 8.13 5.75 1000/D
2x70 rm 1.4 0.3 1.9 34.5 2600 621 D.268 30 230 230 25.46 11.38 8.05 1000/D
2x95 rm 1.6 0.5 2.1 40.4 3745 727 0.193 30 280 275 34.55 15A5 10.93 1000/D
2x120 rm 1.6 0.5 2.2 43.8 4476 788 0.153 30 320 320 43.64 19.52 13.80 1000/D
2x150 rm 1.8 0.5 2.4 48.4 541 8 871 0.124 20 355 379 54.55 24.40 17.25 500/D
2x185 rm 2.0 0.5 2.5 53.3 6649 959 0.0991 20 409 430 67.28 30.09 21.28 500/D
2x240 rm 2.2 0.5 2.7 59.7 8524 1,075 0.0754 20 472 510 87.28 39.03 27.60 250/D
2x300 rm 2.4 0.5 2.9 65.8 10229 1,184 0.0601 20 525 590 109.10 48.79 34.50 250/D
[email protected] 37
Copper Conductor PVC Insulated, & PVC Sheathed Armoured Power Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Specification :
SPLN 43-3 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath:
IEC 60502-1 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
Identification of core: (SPLN) request
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Steel of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation Tape sheath radius delivery
section thickness Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
3x4 re 1.0 0.3 1.8 16.4 499 295 4.61 50 41 34 145 0.65 0.46 1000/D
3x4 rm 1.0 0.3 1.8 17.2 534 310 4.61 50 41 34 145 0.65 0.46 1000/D
3x6 re 1.0 0.3 1.8 17.5 591 315 3.08 50 52 44 2.18 0.98 0.69 1000/D
3x6 rm 1.0 0.3 1.8 18.4 638 331 3.08 50 52 44 2.18 0.98 0.69 1000/D
3x10 rm 1.0 0.3 1.8 20.4 835 367 1.83 50 69 60 3.64 1.63 1.15 1000/D
3x16 rm 1.0 0.3 1.8 22.5 1159 405 1.15 40 89 80 5.82 2.60 1.84 1000/D
3x25 rm 1.2 0.3 1.8 26.2 15.17 472 0.727 40 116 105 9.09 4.07 2.88 1000/D
3x35 rm 1.2 0.3 1.8 28.6 1894 515 0.524 40 138 130 12.73 5.69 4.03 1000/D
3x50 sm 1.4 0.3 1.9 30.5 2238 549 0.387 30 165 160 18.18 8.13 5.75 1000/D
3x70 sm 1.4 0.3 2.0 33.9 3007 610 0.268 30 205 200 25.46 11.38 8.05 1000/D
3x95 sm 1.6 0.5 2.2 38.9 4256 700 0.193 30 245 245 34.55 15.45 10.93 1000/D
3x120 sm 1.6 0.5 2.3 41.6 5124 749 0.153 30 285 285 43.64 19.52 13.80 1000/D
3x150 sm 1.8 0.5 2.4 45.6 6223 821 0.124 20 315 325 54.55 24.40 17.25 500/D
3x185 sm 2.0 0.5 2.6 49.4 7613 889 0.0991 20 355 370 67.28 30.09 21.28 500/D
3x240 sm 2.2 0.5 2.8 54.8 9623 986 0.0754 20 415 435 87.28 39.03 27.60 250/D
3x300 sm 2.4 0.5 3.0 59.7 11588 1.075 0.0601 20 465 500 109.10 48.79 34.50 250/D
38 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Specification :
SPLN 43-3 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
sector shape according to SPLN 41 - 1 ; IEC 60228
5. Outer sheath:
2. Insulation: Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : special flame retardant, PVC sheath can be provided on request.
IEC 60502-1
4. Armour
Two layers of galvanized steel tape helically applied
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Steel of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation Tape sheath radius delivery
section thickness Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
4x2.5 re 0.8 0.3 1.8 16.4 499 295 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x2.5 rm 0.8 0.3 1.8 17.2 534 310 7.41 50 32 25 0.91 0.41 0.29 1000/D
4x4 re 1.0 0.3 1.8 16.4 499 295 4.61 50 41 34 1.45 0.65 0.46 1000/D
4x4 rm 1.0 0.3 1.8 17.2 534 310 4.61 50 41 34 1.45 0.65 046 1000/D
4x6 re 1.0 0.3 1.8 17.5 591 315 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x6 rm 1.0 0.3 1.8 18.4 638 331 3.08 50 52 44 2.18 0.98 0.69 1000/D
4x10 rm 1.0 0.3 1.8 19.4 1101 349 1.83 50 69 60 3.64 1.63 1.15 1000/D
4x16 rm 1.0 0.3 1.8 21.8 1455 392 1.15 40 89 80 5.82 2.60 1.84 1000/D
4x25 rm 1.2 0.3 1.8 25.9 2093 466 0.727 40 116 105 9.09 4.07 2.88 1000/D
4x35 rm 1.2 0.3 1.9 28.6 2602 515 0.524 40 138 130 12.73 5.69 4.03 1000/D
4x50 sm 1.4 0.3 2.0 30 3080 540 0.387 30 165 160 18.18 8.13 5.75 1000/D
4x70 sm 1.4 0.5 2.2 34.1 4093 614 0.268 30 205 200 25.46 11.38 8.05 1000/D
4x95 sm 1.6 0.5 2.4 38.7 5370 697 0.193 30 245 245 34.55 15.45 10.93 1000/D
4x120 sm 1.6 0.5 2.5 42.6 6563 767 0.153 30 285 285 43.64 19.52 13.80 1000/D
4x150 sm 1.8 0.5 2.6 46.3 7938 833 0.124 20 315 325 54.55 2440 17.25 500/D
4x185 sm 2.0 0.5 2.8 52.2 9756 940 0.0991 20 355 370 67.28 30.09 21.28 500/D
4x240 sm 2.2 0.5 3.0 58.5 12409 1,053 0.0754 20 415 435 87.28 39.03 27.60 250/D
4x300 sm 2.4 0.5 3.2 65.4 15104 1,177 0.0601 20 465 500 109.10 48.79 34.50 250/D
[email protected] 39
Copper Conductor PVC Insulated & PVC Sheathed Armoured Power Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Specification :
SPLN 43-3 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or 5. Outer sheath:
according to SPLN 41 - 1 ; IEC 60228 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
2. Insulation: request
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 Applications:
For indoor installations, in power and switching stations.
Identification of core: (SPLN) As underground cable, for difficult installation where the low
Yellow/Green strip, Light Blue, Red, Yellow, Black weight is particularly advantageous.
4. Armour:
Two layers of galvanized steel tape helically applied
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Steel of outer Diameter of Cable bending Capacity at 30°C Current Capacity at Standard
and cross Insulation Tape sheath radius delivery
section thickness Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
5x4 re 1.0 0.3 1.8 18.7 656 337 4.61 50 41 34 1.45 0.65 0.46 1000/D
5x4 rm 1.0 0.3 1.8 19.7 704 355 4.61 50 41 34 1.45 0.65 0.46 1000/D
5x6 re 1.0 0.3 1.8 20.1 842 362 3.08 50 52 44 2.18 0.98 0.69 1000/D
5x6 rm 1.0 0.3 1.8 21.2 857 382 3.08 50 52 44 2.18 0.98 0.69 1000/D
5x10 rm 1.0 0.3 1.8 23.7 1149 427 1.83 50 69 60 3.64 1.63 1.15 1000/D
5x16 rm 1.0 0.3 1.8 26.3 1498 473 1.15 40 89 80 5.82 2.60 1.84 1000/D
5x25 rm 1.2 0.3 1.8 31 2365 558 0.727 40 116 105 9.09 4.07 2.88 1000/D
5x35 rm 1.2 0.3 2.0 34.6 2803 623 0.524 40 138 130 12.73 5.69 4.03 1000/D
5x50 rm 1.4 0.5 2.2 40.4 3909 727 0.387 30 165 160 18.18 8.13 5.75 1000/D
40 www.kabelindo.co.id
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Specification :
SPLN 43-3 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228
4. Armour
2. Insulation: Two layers of galvanized steel tape helically applied
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 :
IEC 60502-1 5. Outer sheath:
Extruded Polyvinyl Chloride [PVC], Black colour, Anti termite and/or
Identification of core : (SPLN) special flame retardant, PVC sheath can be provided on request.
Colour of insulation
System - i System - o
Applications:
Yellow/Green strip, Black with White number Black with White number
For installations as underground, outdoor, indoor in ducts and where
mechanical protection is required or for higher tensile stresses during
(SNI IEC) : installation and operation.
Black with White number
Note : [re] round solid conductor
3. Inner Covering / filler: [rm] circular stranded conductor
Extruded Polyvinyl Chloride [PVC], Black colour
Packing : [D] Drum
No. of Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
cores of Steel of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
and cross Insulation Tape sheath radius delivery
section thickness Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (nom) (approx) (approx] Max Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
7x1.5 re 0.8 0.3 1.8 15.9 458 286 12.1 50 17 13 0.55 0.24 0.17 1000/D
7x1.5 rm 0.8 0.3 1.8 16.4 483 295 12.1 50 17 13 0.55 0.24 0.17 1000/D
8x1.5 re 0.8 0.3 1.8 16.9 508 304 12.1 50 16 12 0.55 0.24 0.17 1000/D
8x1.5 rm 0.8 0.3 1.8 17.5 537 315 12.1 50 16 12 0.55 0.24 0.17 1000/D
10x1.5 re 0.8 0.3 1.8 18.8 609 338 12.1 50 15 11 0.55 0.24 0.17 1000/D
10x1.5 rm 0.8 0.3 1.8 19.6 642 353 12.1 50 15 11 0.55 0.24 0.17 1000/D
12x1.5 re 0.8 0.3 1.8 19.3 657 347 12.1 50 14 11 0.55 0.24 0.17 1000/D
12x1.5 rm 0.8 0.3 1.8 20.1 695 362 12.1 50 14 11 0.55 0.24 0.17 1000/D
14x1.5 re 0.8 0.3 1.8 20.2 721 364 12.1 50 13 10 0.55 0.24 0.17 1000/D
14x1.5 rm 0.8 0.3 1.8 20.9 763 376 12.1 50 13 10 0.55 0.24 0.17 1000/D
16x1.5 re 0.8 0.3 1.8 21 785 378 12.1 50 12 10 0.55 0.24 0.17 1000/D
16x1.5 rm 0.8 0.3 1.8 21.8 831 392 12.1 50 12 10 0.55 0.24 0.17 1000/D
19x1.5 re 0.8 0.3 1.8 22 857 396 12.1 50 12 9 0.55 0.24 0.17 1000/D
19x1.5 rm 0.8 0.3 1.8 22.8 907 410 12.1 50 12 9 0.55 0.24 0.17 1000/D
21x1.5 re 0.8 0.3 1.8 22.7 924 409 12.1 50 11 9 0.55 0.24 0.17 1000/D
21x1.5 rm 0.8 0.3 1.8 23.7 972 427 12.1 50 11 9 0.55 0.24 0.17 1000/D
24x1.5 re 0.8 0.3 1.8 24.2 1027 436 12.1 50 11 8 0.55 0.24 0.17 1000/D
24x1.5 rm 0.8 0.3 1.8 25.3 1087 455 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 re 0.8 0.3 1.8 26 1205 468 12.1 50 11 8 0.55 0.24 0.17 1000/D
30x1.5 rm 0.8 0.3 1.8 27.2 1277 490 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 re 0.8 0.3 1.9 28.6 1488 515 12.1 50 11 8 0.55 0.24 0.17 1000/D
40x1.5 rm 0.8 0.3 1.9 30.1 1577 542 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 re 0.8 0.3 2.0 32.3 1871 581 12.1 50 11 8 0.55 0.24 0.17 1000/D
52x1.5 rm 0.8 0.3 2.0 33.9 1882 610 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 re 0.8 0.3 2.0 34 2110 612 12.1 50 11 8 0.55 0.24 0.17 1000/D
61x1.5 rm 0.8 0.3 2.0 36.6 2428 659 12.1 50 11 8 0.55 0.24 0.17 1000/D
[email protected] 41
Copper Conductor PVC Insulated & PVC Sheathed Armoured Control Cable
Cu/PVC/DSTA/PVC 0.6/1 kV (NYBY)
Specification :
SPLN 43-3 : 1994
IEC 60502-1 : 2004
SNI IEC 60502-1 : 2009
Constructions:
1. Conductor:
Annealed plain copper round solid or round circular stranded or
according to SPLN 41 - 1 ; IEC 60228 4. Armour:
Two layers of galvanized steel tape helically applied
2. Insulation:
Extruded layer of Polyvinyl Chloride (PVC] complied with SPLN 41-2 : 5. Outer sheath:
IEC 60502-1 Extruded Polyvinyl Chloride [PVC] Black colour, Anti termite
and/or special flame retardant. PVC sheath can be provided on
Identification of core: (SPLN) request
Colour of insulation
System - i System - o Applications:
Yellow/Green strip, Black with White number Black with White number For indoor installations, in power and switching stations.
As underground cable, for difficult installation where the low
(SNI IEC) weight is particularly advantageous.
Black with White number
Note : [re] round solid conductor
3. Inner covering /filler: [rm] circular stranded conductor
Extruded Polyvinyl Chloride (PVC), Black colour
Packing : [D] Drum
No. of cores Thickness Armour Thickness Overall Weight Minimum DC. Resistance Current Carrying Conductor Short Circuit
and cross of Steel of outer Diameter of Cable bending at 20°C Capacity at 30°C Current Capacity at Standard
section area Insulation Tape sheath radius delivery
thickness Conductor Insulation in Ground in Air 0.1 0.5 1.0 length
(nom) (nom) (nom) (approx) (approx) Max Min second second second
sq.mm mm sq.mm mm mm kg/km mm Ohm/km M.Ohm.km A A kA kA kA m
7x2.5 re 0.8 0.3 1.8 17 561 306 7.41 50 23 13 0.91 0.41 0.29 1000/D
7x2.5 rm 0.8 0.3 1.8 17.8 597 320 7.41 50 23 13 0.91 0.41 0.29 1000/D
8x2.5 re 0.8 0.3 1.8 18.1 624 326 7.41 50 21 12 0.91 0.41 0.29 1000/D
8x2.5 rm 0.8 0.3 1.8 19 666 342 7.41 50 21 12 0.91 0.41 0.29 1000/D
10x2.5 re 0.8 0.3 1.8 20.3 752 365 7.41 50 20 11 0.91 0.41 0.29 1000/D
10x2.5 rm 0.8 0.3 1.8 21.4 803 385 7.41 50 20 11 0.91 0.41 0.29 1000/D
12x2.5 re 0.8 0.3 1.8 21.8 822 392 7.41 50 18 11 0.91 0.41 0.29 1000/D
12x2.5 rm 0.8 0.3 1.8 22 878 396 7.41 50 18 11 0.91 0.41 0.29 1000/D
14x2.5 re 0.8 0.3 1.8 21.7 909 391 7.41 50 17 10 0.91 0.41 0.29 1000/D
14x2.5 rm 0.8 0.3 1.8 23 971 414 7.41 50 17 10 0.91 0.41 0.29 1000/D
16x2.5 re 0.8 0.3 1.8 22.7 996 409 7.41 50 17 10 0.91 0.41 0.29 1000/D
16x2.5 rm 0.8 0.3 1.8 24 1063 432 7.41 50 17 10 0.91 0.41 0.29 1000/D
19x2.5 re 0.8 0.3 1.8 23.7 1097 427 7.41 50 16 9 0.91 0.41 0.29 1000/D
19x2.5 rm 0.8 0.3 1.8 25 1164 450 7.41 50 16 9 0.91 0.41 0.29 1000/D
21x2.5 re 0.8 0.3 1.8 24.8 1188 446 7.41 50 15 9 0.91 0.41 0.29 1000/D
21x2.5 rm 0.8 0.3 1.8 26.1 1267 470 7.41 50 15 9 0.91 0.41 0.29 1000/D
24x2.5 re 0.8 0.3 1.8 26.2 1327 472 7.41 50 14 8 0.91 0.41 0.29 1000/D
24)x2.5 rm 0.8 0.3 1.8 26.3 1415 473 7.41 50 14 8 0.91 0.41 0.29 1000/D
30x2.5 re 0.8 0.3 1.9 27.9 1472 502 7.41 50 14 8 0.91 0.41 0.29 1000/D
30x2.5 rm 0.8 0.3 1.9 28A 1677 511 7.41 50 14 8 0.91 0.41 0.29 1000/D
40x2.5 re 0.8 0.3 2.0 31.4 1965 565 7.41 50 14 8 0.91 0.41 0.29 1000/D
40x2.5 rm 0.8 0.3 2.0 33.4 2095 601 7.41 50 14 8 0.91 0.41 0.29 1000/D
52x2.5 re 0.8 0.5 2.2 36.2 2722 652 7.41 50 14 8 0.91 0.41 0.29 1000/D
52x2.5 rm 0.8 0.5 2.2 38.5 2904 693 7.41 50 14 8 0.91 0.41 0.29 1000/D
61x2.5 re 0.8 0.5 2.2 39.1 3144 704 7.41 50 14 8 0.91 0.41 0.29 1000/D
61x2.5 rm 0.8 0.5 2.2 40.6 3278 731 7.41 50 14 8 0.91 0.41 0.29 1000/D
42 www.kabelindo.co.id
DERATING FACTORS
[email protected] 43
DERATING FACTORS
44 www.kabelindo.co.id
DERATING FACTORS
[email protected] 45
DERATING FACTORS
46 www.kabelindo.co.id
DERATING FACTORS
[email protected] 47
Conversion Table of Conductor Size
48 www.kabelindo.co.id
STANDARDS
[email protected] 49
NOTES
www.kabelindo.co.id