HM-TRLR-D Series - EN - V1.1
HM-TRLR-D Series - EN - V1.1
HM-TRLR-D Series - EN - V1.1
1. General
HM-TRLR-D series is a low cost, high performance transparent
transceiver with operating at 433/470/868/915 MHz. It is LoRa/FSK/
GFSK/OOK modulation variety, multi-interface mode(TTL/RS232/RS485),
high output power, high sensitivity, long transmission distance and most of
the parameters can be set via the command. Receive and send data to
automatically switch. It has a wide operating voltage and low sleep current.
It is flexible for the users to set the UART baud rate, output power, data
rate, frequency select, modulation mode select etc parameters. It is your
ideal choice for designing wireless data transmission products which can
be widely used on wireless data transmission field.
HM-TRLR-D-YYY-XXX
2. Features
l Low cost, high performance , high reliability
l LoRa/FSK/GFSK/OOK modulation, 2-way half –duplex communication, strong anti-interfere
l 433/470/868/915MHz ISM band,globally license free.
l Maximal output power100mW(20dBm),output power adjustable between 2-20dBm
l LORA Sensitivity -139dBm
l Supply current for Tx 130mA@20dBm, 35mA@13dBm
l Supply current for Rx 20mA
l Low current sleep mode 2uA
l Wide operating voltage:3.3V-5.5V
l Standard TTL UART/RS232/RS485 interface
l Operation frequency can be configured, acceptable for several modules working in different frequency
with no disturbance on each other.
l RF parameters as needed, users can be modulated by software.
l Easily use, auto exchange on communication & transceiver
l Communication speed 1.2kbps -115.2kbps,can be modulated through software
l Afford Sleep control signal,user self control work duty cycle
l With LED indication
l Longer transmission distance,over 5Km in open air
l Small size 26*47*2mm, easy for assembly .
l Tuning free
l Accord FCC,ETSI standard
3. Application
l Remote control, remote measurement l Wireless meter
system; l Identification system
l Access control
l Data collection l IT household appliance
l Intelligence household appliance l Baby monitoring system
1
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
4. Pin Description
TOP VIEW
5. Maximum specifiction
2
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
6. Parameter
20dBm output
120
power
Tx Current mA
13dBm output
35
power
Rx Current 18 20 22 mA
Sleep Current TBD 8 12 uA
Modulate deviation FSK mode 10 50 KHz
Receive bandwidth FSK mode 42 166 KHz
UART Data Rate 1.2 115.2 Kbps
UART data bit 8 bit
UART stop bit 1 bit
3
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
4
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
5
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
9.Ordering Information
6
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
1. Modulation mode
HM-TRLR series transceiver module can work with the traditional FSK/GFSK modulation mode, also can
work in LoRa modulation mode. The user according to the application requirements, can easily switch in
modulation mode. Use principle need large quantities of data use FSK/GFSK modulation; The occasion of long
distance transmission is required, use LoRa modulation.
2.Work mode
HM-TRLR series transceiver module has three work modes: running mode, configuration mode and sleep mode.
When the module work in the running mode, the user can send and receive data. When the module work in
configuration mode, the user can according to his requirement, through the AT command to change configuration
parameters. Sleep mode module into low power consumption mode.
Attention: During the modulation mode in LoRa receive buffer is full,the STATUS will lower the output to prompt
the user.
7
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
Attention:When enter to the configuration mode ,through to pull down the the CONFIG ,while the STATUS
goes low. The user can change the parameter by AT command.
8
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
3.Channel frequency
HM-TRLR series module have different working frequencies according to its model.
The frequencies have divided to 16 channel. Frequencies list is as follow(Black said Jumper).
Select Channel 433MHz Band 470MHz Band 868MHz Band 915MHZ Band
CH_1○○ 0
CH_2○○
430000000.00 470000000.00 863000000.00 915000000.00
CH_3○○
CH_4○○
CH_1●● 1
CH_2○○
430500000.00 470400000.00 863500000.00 915500000.00
CH_3○○
CH_4○○
CH_1○○ 2
CH_2●●
431000000.00 470800000.00 864000000.00 916000000.00
CH_3○○
CH_4○○
CH_1●● 3
CH_2●●
431500000.00 471200000.00 864500000.00 916500000.00
CH_3○○
CH_4○○
CH_1○○ 4 917000000.00
CH_2○○ 432000000.00 471600000.00 865000000.00
CH_3●●
9
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
CH_4○○
CH_1●● 5
CH_2○○
432500000.00 472000000.00 865500000.00 917500000.00
CH_3●●
CH_4○○
CH_1○○ 6
CH_2●●
433000000.00 472400000.00 866000000.00 918000000.00
CH_3●●
CH_4○○
CH_1●● 7
CH_2●●
433500000.00 472800000.00 866500000.00 918500000.00
CH_3●●
CH_4○○
CH_1○○ 8
CH_2○○
434000000.00 473200000.00 867000000.00 919000000.00
CH_3○○
CH_4●●
CH_1●● 9
CH_2○○
434500000.00 473600000.00 867500000.00 919500000.00
CH_3○○
CH_4●●
CH_1○○ 10
CH_2●●
435000000.00 474000000.00 868000000.00 920000000.00
CH_3○○
CH_4●●
CH_1●● 11
CH_2●●
435500000.00 474400000.00 868500000.00 920500000.00
CH_3○○
CH_4●●
CH_1○○ 12
CH_2 ○○
436000000.00 474800000.00 869000000.00 921000000.00
CH_3●●
CH_4●●
CH_1●● 13
CH_2○○
436500000.00 475200000.00 869500000.00 921500000.00
CH_3●●
CH_4●●
CH_1○○ 14
CH_2●●
437000000.00 475600000.00 870000000.00 922000000.00
CH_3●●
CH_4●●
CH_1●● 15
CH_2●●
437500000.00 476000000.00 870500000.00 922500000.00
CH_3●●
CH_4●●
10
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
Select Parity
U_EVEN○○ None Check
U_ODD ○○
U_EVEN●● EVEN Check
U_ODD ○○
U_EVEN○○ Odd Check
U_ODD ●●
5.Wireless rate
l When the HM-TRLR module is working on FSK modulation. The wireless rate conform to baud rate.
Theoretically it can transmit data boundless. We suggest that if the data package is too large ,you should use
the subcontract transmission in order to avoid the air data interference.
l When the HM-TRLR module is working on LoRa modulation. The wireless rate is depend on signal
bandwidth、spreading factor、coding rate、payload length.. However the receiver sensitivity is depend on
signal bandwidth and spreading factor. The following table shows the relationship between the wireless rate
and parameter.
Test conditions:
u Supply voltage = 3.3 V
u Temperature = 25° C
u CRC on payload enabled
u Payload length = 64 bytes
u Coding Rate = 1
FreqStep = 61Hz*FreqStepValue
FreqStepValue = 0~65535
Note: when the ID function is enabled, Interval time of two frame greater than Td time, The first byte of each frame
is a node ID or broadcast ID.
8. Td Delay time
12
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
BandRate(bps) Td
1200 73ms
2400 37ms
4800 19ms
9600 10ms
14400 7ms
19200 6ms
38400 4ms
56000 3ms
57600 3ms
115200 2ms
In LoRa modulation, Wireless data transmission is the subcontract, If the length of data is more than payload length
and wireless rate less than the rate of serial port, The receiver of data will be interrupted. In the sending end, If the
receive buffer is full the STATUS will lower the output to prompt the user.
Wireless rate is greater than the rate of serial port, As the following figure.
Wireless rate is less than the rate of serial port, As the following figure.
13
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
Testing Conditions:
u Spread Factor = 9
u Singal Band Width = 250kHz
u Code Rate = 1
u PayLoad = 32 bytes
BaudRate(bps) Td
1200 Max 410ms
2400 Max 270ms
4800 Max 200ms
9600 Max 166ms
14400 Max 153ms
19200 Max 146ms
38400 Max 138ms
56000 Max 136ms
57600 Max 135ms
115200 Max 134ms
14
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
1.Introduction
The controller through IO port make HM-TRLR-S transceiver been to configuration mode.Then through serial
port send AT command to Modify the performance parameters.
2.Command format
Command used capital letter ASCII to write and used <CR> to end. When to module receive command it will
explain and reply it.
15
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
3. Command type
3.1 Set Uart BaudRate command
The baudrate refers to the controller communication speed, when set, after the completion of new baudrate takes
effect immediately, The controller should with new baudrate and communication module.
16
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
17
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
18
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
6—62.5KHZ
n 6~9 7—125KHZ
8—250KHZ
9—500KHZ
19
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
20
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
21
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
22
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
23
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
24
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com
HM-TRLR-D Series 100mW LoRa Transceiver ver1.1
版本号 章节 变更描述 日期
1.0 All Initial released version 2014-3
1.1 Page3 Parameter Update the Sleep Current 2016-3