Pump Control (Output Flow) - Adjust - Stage 2 Pump
Pump Control (Output Flow) - Adjust - Stage 2 Pump
Página 1 de 5
Cerrar SIS
Pantalla anterior
Producto: EXCAVATOR
Modelo: 336D L EXCAVATOR M4T
Configuración: 336D L Excavators M4T00001-UP (MACHINE) POWERED BY C9 Engine
Pruebas y Ajustes
330D, 336D and 340D Excavators Hydraulic System
Número de medio -RENR9585-16 Fecha de publicación -01/05/2012 Fecha de actualización -10/05/2012
i03021084
Número de pieza -
S/N - MPL1-UP
Número de pieza -
S/N - ZML1-UP
Número de pieza -
S/N - W3K1-UP
Número de pieza -
S/N - JJM1-UP
Número de pieza -
S/N - JLP1-UP
Número de pieza -
S/N - MDS1-UP
Número de pieza -
S/N - KKT1-UP
Número de pieza -
S/N - PRF1-UP
Número de pieza -
S/N - EAH725-UP
Número de pieza -
S/N - EDX1-UP
Número de pieza -
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 30/08/2012
336D L Excavators M4T00001-UP (MACHINE) POWERED BY C9 Engine(SEBP538... Página 2 de 5
S/N - NBD841-UP
Número de pieza -
S/N - MWP2132-UP
Número de pieza -
S/N - M4T1-UP
Número de pieza -
S/N - R2D1-UP
Número de pieza -
S/N - J2F1-UP
Número de pieza -
S/N - FFK326-UP
Número de pieza -
S/N - WRK1-UP
Número de pieza -
S/N - MEY311-UP
Número de pieza -
S/N - B6H1-UP
Número de pieza -
S/N - JTN1-UP
Número de pieza -
S/N - JBT1-UP
Número de pieza -
S/N - PGW1-UP
Adjust the pump output flow if the flow test results differ greatly from the specifications.
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 30/08/2012
336D L Excavators M4T00001-UP (MACHINE) POWERED BY C9 Engine(SEBP538... Página 3 de 5
Illustration 1 g01368631
(2) Locknut
(4) Locknut
(6) Locknut
(8) Locknut
Adjust the flow of the drive pump for the first stage of the constant horsepower control. The idler
pump must be at no-load condition.
2. Turn adjustment screw (3) in order to adjust the output flow of the pump. Turning adjustment
screw (3) clockwise will increase the output flow of the pump. Turning adjustment screw (3)
counterclockwise will decrease the output flow of the pump. A 1/4 turn of adjustment screw (3)
will change the output flow of the pump at the following pressure.
◦ Output flow of the pump will change approximately 24.5 L/min (6.5 US gpm) if the
output flow is adjusted in the pressure range of 10000 kPa (1450 psi) to 21000 kPa (3050
psi). The pump is operating in the first stage of the constant horsepower control.
Adjust the flow of the drive pump for the second stage of the constant horsepower control. The idler
pump must be at no-load condition.
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 30/08/2012
336D L Excavators M4T00001-UP (MACHINE) POWERED BY C9 Engine(SEBP538... Página 4 de 5
2. Turn adjustment screw (1) in order to adjust the output flow of the pump. Turning adjustment
screw (1) clockwise will increase the output flow of the pump. Turning adjustment screw (1)
counterclockwise will decrease the output flow of the pump. A 1/4 turn of adjustment screw (1)
will change the output flow of the pump at the following pressure.
◦ Output flow of the pump will change approximately 13.2 L/min (3.5 US gpm) if the
output flow is adjusted in the pressure range of 28000 kPa (4050 psi) to 31000 kPa (4500
psi). The pump is operating in the second stage of the constant horsepower control.
Adjust the idler pump in the same manner as the drive pump. Use locknut (8) and adjustment screw
(7) in order to adjust the first stage of the constant horsepower control. Use locknut (6) and
adjustment screw (5) in order to adjust the second stage of the constant horsepower control.
Illustration 2 g01526725
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 30/08/2012
336D L Excavators M4T00001-UP (MACHINE) POWERED BY C9 Engine(SEBP538... Página 5 de 5
(10) Locknut
(11) Locknut
2. In order to adjust maximum output flow, turn adjustment screw (12). Turning adjustment screw
(12) clockwise will decrease the maximum output flow of the pump. Turning adjustment screw
(12) counterclockwise will increase the maximum output flow of the pump. A 1/4 turn of
adjustment screw (12) will change the maximum output flow approximately 5.5 L/min (1.5 US
gpm).
Adjust the maximum output flow of the idler pump in the same manner as the drive pump. Use
locknut (10) and adjustment screw (9) in order to adjust the maximum output flow of the idler pump.