Regulatory, safety and environmental notices
Products bearing the CE marking comply with one or more of the following EU Directives as may be applicable:
Compliance with these directives is assessed using applicable European Harmonised Standards.<<<
The installation of this product should be made by a qualified service Person and should comply with all local regulations.
It is strongly recommended to use a class II power supply at 12V-24V and 2.5 A. min (at 12V) in conformity with Safety Electrical Low Voltage
(SELV). The power supply cable length should not exceed 10 meters.
This system must be installed in accordance with the National Electrical Code (NFPA 70), and the local authority having jurisdiction.
This product is intended to be installed with a power supply complying with IEC60950-1, in accordance with the NEC Class 2 requirements; or
supplied by a listed IEC60950-1 external Power Unit marked Class 2, Limited Power source, or LPS and rated 12VDC, 2.5 A minimum or 24VDC,
1.25 A minimum.
In case of building-to-building connection it is recommended to connect 0V to ground. Ground cable must be connected with the terminal block
Power Ground.
Note that all connections of the MorphoWave Compact terminal described hereafter are of SELV (Safety Electrical Low Voltage) type.
This symbol means do not dispose of your product with your other household waste. Instead, you should protect human health and the environment
by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment.
3 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Product Overview
Speaker
MorphoWave Compact provides an Status LED
innovative and effective solution for access
control applications using very fast
acquisitions of four (4) fingerprints without Contactless 4.3'’ WVGA
any contact. card area touchscreen LCD
4 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoWave Compact Checklist
QTY ITEM
1 MorphoWave Compact terminal
1 Wall Mounting Plate
1 Documentation package
5 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Terminal Implementation
To secure an access, IDEMIA recommends installing the MorphoWave Compact terminal as a part of a typical Access Control system,
which consists of the components described below.
6 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Typical Access Control Process
Note: One user must be enrolled in the terminal database, in order to be able to perform biometric check.
7 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Access Control Modes
The terminal can be configured in one of the modes described in the table below
Identification Authentication Multifactor Proxy
Access Application that runs Application that runs Application that runs Remote application
control on the terminal when on the terminal when on the terminal when that controls the
application it starts. it starts. it starts. terminal through
network commands
Access A user swipes his/her A user places a Both Identification Triggering events are
control hand in the biometric contactless card in and Authentication selected by the
triggering sensor. front of the reader. (*) triggers are enabled. remote application
event
Biometric The user’s captured The user’s captured As per Identification Selected by the
check (if fingerprints are fingerprints are or Authentication, remote application
enabled) matched against all matched against depending on the
fingerprints in the their reference triggering event
terminal database. fingerprints. (**)
8 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Deployment Environment
Operating temperature -10°to + 55 °C (14°to 131°F) when ECO-Mode ON
-10°to + 45 °C (14°to 113°F) when ECO-Mode OFF
Operating humidity 10 % < RH < 80 % (non condensing)
Storage temperature -25°to + 70 °C (-13°to 158°F)
Storage humidity 5% < RH < 95 %
IP code IP65 rated
Do not deactivate ECO-mode when working at a temperature above 45°C (113°F), to avoid over-
heating.
General precautions
Do not expose the terminal to extreme temperatures.
When the environment is very dry, avoid synthetic carpeting near the MorphoWave Compact terminal, to
reduce the risk of unwanted electrostatic discharge.
Areas containing combustibles
9 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Wiring Overview Pin numbers shown in this document correspond to the
internal connector pinout in the product. The connector
RJ-45 : Ethernet & PoE attached to the cable is for test only and should be removed
1 ETH TX+ Orange / White for installation.
2 ETH TX- Orange
3 ETH RX+ Green / White
4 ETH VPORT+ Blue
RJ45
5 ETH VPORT+ Blue / White RS-422 and 485
6 ETH RX- Green 7 RS485_RX_A Blue / Black
7 ETH VPORT- Brown / White 8 RS485_TX_Z Green / White
8 ETH VPORT- Brown 9 RS485_RX_B Blue / White
Shell ETH GND Drain wire (no color) GPIO
10 RS485_TX_Y Green / Black
19 GPI2 Orange / Black
11 RS485_GND Black / Red
20 GPO2 Yellow / Red
17 GPI1 Orange / Red Wiegand IN & Wiegand OUT
18 GPO1 Yellow / Red 25 WIEGAND_LEDOUT1 Blue
Power supply & Tamper switch 15 GPI0 Orange 28 WIEGAND_LEDOUT2 Blue / Red
13 RLY_NC Orange / White 16 GPO0 Yellow 23 WIEGAND_IN1 White / Red
14 RLY_NO Yellow / White 22 GPIO_GND Black / Red 24 WIEGAND_OUT0 Green
12 RLY_COM Grey / White 26 WIEGAND_OUT1 White
5 SWITCH_PIN1 Light Blue 21 WIEGAND_IN0 Green / Red
6 SWITCH_PIN2 Pink 27 WIEGAND_GND Black / Red
1,3 Power + 12V Red
2,4 Power GND Black
All connections of the terminal are of SELV (Safety Electrical Low Voltage) type.
Backup of the Date/Time of the terminal: the volatile settings (such as date/time) of the terminal are protected against
power failure, by a dedicated component during a least 24 hours (at 25 oC) without external power supply.
10 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Power supply
Power Over Ethernet (POE+): power can be provided through RJ-45 connector
RJ45 using a PSE (Power Sourcing Equipment) IEEE802.3at type 2 compliant.
The terminal is a Class 4 (25.5 W) PD (Powered Device).
External Power Supply: 12-24 Volts (regulated and filtered) 2.5 Amp min @12 V, CEE/EEC EN60950
standard compliant. If sharing power between devices, each unit must receive 2.5 A (e.g. two units would
require a 12 VDC, 5 A supply).
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is recommended.
IDEMIA recommends using a 24V power supply and AWG16 gauge Maximum distance (meters)
cable. The voltage measured on the product block connector of the Gauge Section
vs power source rating
terminal must be equal to 12V-24V (-15% / +10%). AWG (mm2)
12V+/-10% 12V+/-5% 24V+/-10%
WARNING: Under powering may cause memory and data corruption; over powering may cause hardware damage.
Both of these situations will void the warranty
11 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
RS-485 Communication
RS-232 to
RS-232 RS-485
from the RS-485 to
converter
Com Port 1200m (4000ft)
Choose one twisted pair of conductors to use for RS485_TX_Y (TX+, Green / Black wire - 10) and RS485_TX_Z (TX-, Green
/ White wire - 8). Another conductor should be used for Signal Ground (Black / Red wire - 11).
IMPORTANT:
A maximum of 31 devices may be installed on the same line.
The maximum total cable length is 4000 ft. (1200m).
The cable must be dedicated to this installation and not used for any other purpose
12 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
RS-422 Communication
RS-232 to
RS-232 RS-422
from the RS-422 to
converter
Com Port 1200m (4000ft)
13 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Ethernet and Wireless LAN
1 ETH TX+ Orange / White
2 ETH TX- Orange
3 ETH RX+ Green / White
4 ETH VPORT+ Blue Wireless
5 ETH VPORT+ Blue / White RJ45
6 ETH RX- Green
7 ETH VPORT- Brown / White
8 ETH VPORT- Brown
Shell ETH GND Drain wire (no color)
LAN Ethernet
Management
Use a category 6 shielding cable (120 Ohms) or better. It is strongly recommended
14 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Wiegand Communication
25 WIEGAND_LEDOUT1 Blue LED
28 WIEGAND_LEDOUT2 Blue / Red Out
23 WIEGAND_IN1 White / Red
24 WIEGAND_OUT0 Green
26 WIEGAND_OUT1 White
Wiegand In
21 WIEGAND_IN0 Green / Red
27 WIEGAND_GND Black / Red Wiegand Out
LED In
16 GPO0 Yellow
Three-conductor cable (shielded recommended) is required for Data 0, Data 1, and WGND.
For 18 AWG, the maximum cable distance is 500 ft. (150m); for 20 AWG, the maximum is 300 ft. (90m); for 22
AWG, the maximum is 200 ft. (60m).
15 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Wiegand Communication (continued)
Important Example Format Information
By default, the Wiegand output format is not enabled. Wiegand Type: Standard 26-bit
output must be configured before connecting to the ACP. Alt Site Code and Fail Site Code Range: 0-255
Note Template ID Number Range: 1-65535
On installation, the system administrator will be prompted to Extended ID Number Range: N/A
select either a pre-existing Wiegand frame format or create a ID Start Bit: 9
custom format, and upload it to the unit before the first use. Length of ID: 16
Data Clock Site Code Start bit: 1
The Wiegand port also supports the Clock & Data protocol. Length of Site Code: 8
The wiring is described below. Start Bit length : 0
Card present
16 GPO0 Yellow
(Legacy Morpho Mode)
16 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Single Door Access Control (SDAC)
Single Door Access Control (SDAC) wiring sample : with Push Button
Power supply from electrical source shall be switched off before starting the installation.
17 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Internal Relay Wiring
Protection Diode
RJ45 Power supply
VCC < 30V
Imax < 1A
Deadbolt /
Door strike Warning
This is recommended only for
small or stand-alone
13 RLY_NC Orange / White Push Button applications where access
14 RLY_NO Yellow / White on other side control panels are not available.
12 RLY_COM Grey / White of the door
In this mode it is strongly
recommended to monitor the
Example for Normally
Tamper Detection of the device
Open connection
Inductive load management requires a parallel diode for a better contact lifetime.
18 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Local Administration - First Boot Assistant
The First Boot Assistant (FBA) helps the administrator to Main settings managed by FBA
configure all the device fundamental settings.
Date & Time & Time Zone Settings
It is automatically launched at first terminal startup, but can
also be launched on demand, though administration menu Trigger Event: select event(s) to be processed
(i.e. to reinitialize terminal main settings) as an access request by a user
User Multimedia
Cancel Validation or management management
or refuse confirmation
20 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Administration with MorphoBioToolBox application
The MorphoWave Compact Series
Terminal administration with MorphoBioToolBox (MBTB) application
terminal can be configured using a
dedicated (Windows) application :
MorphoBioToolBox
Please note that this application has
an embedded User Guide (Help
menu).
21 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Software for Terminal Remote Administration
This menu allows a user’s record to be added in the local database, with the
option of creating a user RF card, with the user’s reference data.
23 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Local Enrollment Process 2/2
24 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Acquisition guidelines 1/2
Ideal acquisition procedure
9. Do not place your hand on the 10. Do not place your hand too far
edge of the optical sensor up on the optical sensor
11. Do not tilt your hand (left to 12. Do not insert your hand fingers
right or fingertip to palm)” first from either the left or right
side of the scanner
The user is expected to press one of the keys to provide the specific
Time & Attendance information to the terminal.
28 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Recommendations
The manufacturer cannot be held responsible in case of non-compliance with the following recommendations or incorrect use of the terminal.
Cleaning precautions
A dry cloth should be used to clean the terminal, especially the biometric sensor.
The use of acid liquids, alcohol or abrasive materials is prohibited.
Use dry air spray to remove the dust out of the sensor glass
Firmware release
To get the best of our technology, we recommend you to download and install the last firmware release (please refer to last page)
29 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Documentation
Documents about installing the terminal
MorphoWave Compact Installation Guide, Ref. 2018_2000035853
This document describes the terminals physical mounting procedure, electrical interfaces and connection procedures.
Release note : for each firmware version, a release note is published describing the new features, the supported products, the potential known
issues, the upgrade / downgrade limitations, the recommendations, the potential restrictions…
North and South America: you may obtain these document by e-mailing [email protected] with your name, phone number,
MorphoWave Compact serial number and “Send Links For MorphoWave Compact Documents” in the subject line.
Other countries: please contact your sales representative.
30 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED
Contacts
Technical Support and Hotline
For the latest firmware, software, document releases, and news, please check our websites :
North and South America : e-mailing [email protected] with your name, phone number, MA
SIGMA Extreme serial number and “Send Links For MorphoWave Compact Documents” in the subject line
Other countries : please visit our web site www.biometric-terminals.com (To get your log in and password please
contact your sales representative).
31 IDEMIA - 2018_2000035854 – V1
IDEMIA DOCUMENT – REPRODUCTION AND DISCLOSURE PROHIBITED