Endura Product Brochure
Endura Product Brochure
Endura Product Brochure
EVOLUTION 200
Low-rise elevators
Low- to mid-rise elevators
MOVE BEYOND
MAKING
CITIES
BETTER
02 ENDURA
CONTENTS
02
Making cities better 02
04
Engineering simplified for everyone 04
06
Choose endura 06
Machine room overview 06
Machine room-less overview 07
08
Simply more space 08
22
Planning 22
28
Our core values 28
ENDURA 03
ENGINEERING
SIMPLIFIED
FOR EVERYONE
Contractors
With endura, installation is easy. Our MRL application
guarantees that there's less to build and manage as it
removes the need for framing, electrical, HVAC,
fireproof doors, and the locks and signage necessary
for machine rooms.
Architects
There is no longer a need to worry about designing extra
space for a machine room as endura is a machine-room
less (MRL) application. The power unit is located in the
elevator pit and the controller fits in the door jamb.
A machine room application is available for locations
that require them or customers interested in a stronger
lifting power.
Building owners
This hydraulic elevator has fewer moving parts and
lower maintenance costs than low-rise traction MRLs.
It comes with MAX – our predictive maintenance solution
that can lower elevator downtime by up to 50 percent.
An electronic valve makes floor leveling adjustments
automatically, decreasing unexpected service visits.
A battery-lowering operation (included with our MRL
application) ensures tenants don't become trapped
during a power failure. Nonproprietary user interface
tools allow for unrestricted access for on-board adjusting
and troubleshooting.
ENDURA 05
CHOOSE ENDURA
endura is perfect for low-rise buildings.
Whether you want the architectural design
freedom provided by machine room-less
applications, or if you’re in an area that
requires a machine room — our hydraulic
elevator has it all. Tenants will appreciate
its smooth, quiet and reliable performance.
The simplified design has fewer moving
parts than traction MRL elevators. This
means an easier installation and reduced
maintenance costs.
Fit
Machine Room
Travel
Up to 33'-6½" with
above-ground jack*
Up to 60'-0" with
below-ground jack
06 ENDURA
Machine room-less application.
With our MRL application, all equipment fits in the
hoistway and you no longer need a machine room.
Fit
Machine room-less
Travel
Up to 33'-6½"with above-ground jack*
ENDURA 07
SIMPLY
MORE SPACE
08 ENDURA
1 2 3
4 5
ENDURA 09
SMOOTH
AND RELIABLE
2
4
10 ENDURA
1 2
3 4
ENDURA 11
SIMPLE YET
SOPHISTICATED
We offer you choices, whether you
need vandal-resistant durability or
want to retain a sleek polished interior.
Available in many colors.
Metals1
Metals
ENDURA 13
VERTICAL
APPLIED PANELS
Our cab and finish options let you
personalize your elevator interior. Just
like you want to.
Metals
1
Contact your local representative for detailed availability on our metal options.
ENDURA 15
Finishes
Plastic laminates
Woods
Solids
Patterns
Powder Coats
Metals
1
L imited application. Contact your local representative for details.
Colors may vary. We recommend examining a large color selector sheet before making a selection.
16 ENDURA
Cab accessory options
Ceilings
Basic flat 1
Exposed cab top with optional
recessed lighting.
Suspended
White translucent diffusers with
ceiling frames.
Downlight 2
Metal pan downlight ceiling features
LED lighting with six or nine lights
(based on cab size.)
Handrails
Nickel Silver
Illustrations vary based on configurations. 1 Not available on all models. 2 L ighting options may vary depending on cab size.
ENDURA 17
Fixtures
Combo hall lantern and position Combo hall lantern and position
indicator with directional arrows indicator with directional arrows
Intermediate Terminal
hall station hall station
Push button available in blue, white, red Car operating panel Push button available in red, blue, white Car operating panel
and green LED lighting and green LED lighting
Fixtures shown above are for representation only. Your project-specific application may vary.
18 ENDURA
Door configurations
Door orientation options offer a range of benefits to accommodate different
project needs.
One-speed The most economical Two-speed Provides a wider Center opening Best for high-traffic
door offering, available with either opening without compromising buildings. Permits the quickest entry
right- or left-hand opening. door cycling time. Two doors move and exit, improving elevator service
(right-hand shown) in the same direction, one sliding while giving an attractive,
faster than the other. Available with symmetrical appearance.
either right- or left-hand opening.
(right-hand shown)
Opens right
Opens right at twice the speed Opens from center
Opens right
at normal speed
Opens right at
twice the speed Opens from center
Opens right
Front returns
Column returns Wrap-around returns*
This return features a This return features a
hinged car operating panel hinged car operating
secured to the filler panel panel and separate
and aligned vertically with filler panel.
the column. Comes standard.
Filler Filler
panel panel
Front returns include the car station, return panel, signal fixtures and Images above represent return types in brushed stainless steel.
head jamb. * Comes standard
ENDURA 19
ENTRANCE
OPTIONS
The entrance frame and door
are supplied by TK Elevator.
You'll choose from powder
coats or metal finishes.
20 ENDURA
Entrance finishes
Powder coats
Metals
Contact your local
representative for
detailed availability on
our metal options.
Frame width
2"
⅜"
1
Frame height
ENDURA 21
PLANNING
Above-ground jack applications
Type
Above-ground jack
Travel
Up to 33'-6½"
Capacity
2100 – 5000 lbs
Speed
Machine room-less Machine room 80 – 150 fpm
33'-6½" with standard overhead and pit depth; serves up to six floors with additional
Maximum travel pit and overhead
Jack types Single, Two-stage, Three-stage (telescoping)
Power characteristics 200–480 VAC, 3 phase, 60 hertz; (single-phase application is available as an option)
Controller TAC32
Door operator Universal Door Operator
Manual lowering Standard
22 ENDURA
Below-ground jack applications
Type
Below-ground jack
Travel
Up to 60'-0"
Capacity
2100 – 5000 lbs
Speed
Machine room 80 – 200 fpm
Speeds (fpm) 80, 100, 110, 125, 150, 175, 200 feet per minute
ENDURA 23
endura
Passenger elevators - twinpost above-ground
D B D
C C
E E
A A
D B D
C C
G G
E E
A A
O Minimum overhead:
Up to 100 fpm: Over 100 fpm:
1-Stage – 12'-2" 1-Stage – 12'-5"
Passenger elevator 2-Stage – 12'-8" 2-Stage – 12'-8"
1-and 2-Stage 3-stage
3-Stage – 12'-11" 3-Stage – 12'-11"
Capacity Front / Inside clear Door Door width
Hoistway 2,9 Hoistway 9
(lbs) rear CxD type E
AxB AxB
P Minimum pit depth: 4'-0" 6
2100 3 7'-4" x 5'-9" 7'-8" x 5'-9" F 5'-8" x 4'-3" One-speed 3'-0"
T Max travel possible: 1
2100 3 7'-4" x 6'-8¾" 7'-8" x 6'-8¾" F/R 5'-8" x 4'-3½" One-speed 3'-0"
1-Stage: Up to 100 fpm – 18'-11"
2500 8'-4" x 5'-9" 8'-8" x 5'-9" F 6'-8" x 4'-3" One-speed 3'-6" Over 100 fpm – 18'-8"
2500 4 8'-4" x 6'-8¾" 8'-8" x 6'-8¾" F/R 6'-8" x 4'-3½" One-speed 3'-6" 2-Stage: 28'-6"
3000 4
8'-4" x 6'-3" 8'-8" x 6'-3" F 6'-8" x 4'-9" One-speed 3'-6"
3-Stage: 48'-3½"
3000 4
8'-4" x 7'-2¾" 8'-8" x 7'-2¾" F/R 6'-8" x 4'-9½" One-speed 3'-6" S Safety beam required per
OSHA 1926.502 7
3500 4
8'-4" x 6'-11" 8'-8" x 6'-11" F 6'-8" x 5'-5" One-speed 3'-6"
3500 4 8'-4" x 7'-10¾" 8'-8" x 7'-10¾" F/R 6'-8" x 5'-5½" One-speed 3'-6"
4000 4 9'-4" x 6'-11" 9'-8" x 6'-11" F 7'-8" x 5'-5" One-speed 3'-6"/4'-0" Contact your local representative for various code
or jurisdictional exceptions, or alterations
4000 4 9'-4" x 7'-10¾" 9'-8" x 7'-10¾" F/R 7'-8" x 5'-5½" One-speed 3'-6"/4'-0" required.
24 ENDURA
endura
Service elevators – twinpost above-ground
Top view:
F F Front opening
G G
D B
E
A
Top view:
1, 2 & 3 – Stage Jack
Front and
T T rear opening
D B
C
G G
E
A
O Minimum overhead:
Up to 100 fpm: Over 100 fpm:
1-Stage – 12'-2" 1-Stage – 12'-5"
2-Stage – 12'-8" 2-Stage – 12'-8"
Service 1-and 2-Stage 3-Stage 3-Stage – 12'-11" 3-Stage – 12'-11"
Capacity Hoistway 2,8,9 Hoistway 8,9 Front/ Inside clear Door Door width 8
(lbs) AxB AxB rear CxD type E P Minimum pit depth: 4'-0" 6
4500 7'-4" x 9'-6½" 7'-8" x 9'-6½" F 5'-8" x 7'-9½" Two-speed 4'-0"/4'-6" T Max travel possible: 1
4500 7'-4" x 10'-9¼" 7'-8" x 10'-9¼" F/R 5'-8" x 7'-10" Two-speed 4'-0"/4'-6" 1-Stage: Up to 100 fpm – 18'-11"
Over 100 fpm – 18'-8"
5000 7'-4" x 10'-2" 7'-8" x 10'-2" F 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
2-Stage: 28'-6"
5000 7'-4" x 11'-4¾" 7'-8" x 11'-4¾" F/R 5'-8" x 8'-5½" Two-speed 4'-0"/4'-6" 3-Stage: 48'-3½"
5000H 7'-4" x 10'-9" 7'-8" x 10'-9" F 5'-8" x 9'-0" Two-speed 4'-0"/4'-6" S Safety beam required per
OSHA 1926.502 7
5000H 7'-4" x 11'-11¾" 7'-8" x 11'-11¾" F/R 5'-8" x 9'-0½" Two-speed 4'-0"/4'-6"
ENDURA 25
endura
Passenger elevators - below-ground
D B D
C C
E E
A A
D B D
G G C C
E E
A A
P P
X X F Inside clear height: 7'-4" 5
O Minimum overhead:
Up to 100 fpm – 12'-0"
Over 100 fpm – 12'-3"
Passenger
Capacity Hoistway 2,9 Front/ Inside clear Door Door width P Minimum pit depth: 4'-0" 6
(lbs) AxB rear CxD type E
2100 3 7'-4" x 5'-9" F 5'-8" x 4'-3" One-speed 3'-0" S Safety beam required per
2100 3
7'-4" x 6'-8¾" F/R 5'-8" x 4'-3½" One-speed 3'-0" OSHA 1926.502 7
2500 8'-4" x 5'-9" F 6'-8" x 4'-3" One-speed 3'-6" T Max travel possible: 60'-0"
2500 4
8'-4" x 6'-8¾" F/R 6'-8" x 4'-3½" One-speed 3'-6"
X Standard jack hole depth:
3000 4 8'-4" x 6'-3" F 6'-8" x 4'-9" One-speed 3'-6"
Travel + 6'-0"
3000 4 8'-4" x 7'-2¾" F/R 6'-8" x 4'-9½" One-speed 3'-6"
3500 4
8'-4" x 7'-10¾" F/R 6'-8" x 5'-5½" One-speed 3'-6"
Contact your local representative for
4000 4
9'-4" x 6'-11" F 7'-8" x 5'-5" One-speed 3'-6"/4'-0" various code or jurisdictional exceptions,
4000 4 9'-4" x 7'-10¾" F/R 7'-8" x 5'-5½" One-speed 3'-6"/4'-0" or alterations required.
26 ENDURA
endura
Service elevators – below-ground
O O
Two-speed side opening doors
F F Top view:
G G Front opening
D B
E
A
Top view:
T T Front and
rear opening
D B
G G C
E
A
P P
X X F Inside clear height: 7'-4" 5
O Minimum overhead:
Up to 100 fpm – 12'-0"
Over 100 fpm – 12'-3"
Service
Capacity Hoistway 2,8,9 Front/ Inside clear Door Door width 8 P Minimum pit depth: 4'-0" 6
(lbs) AxB rear CxD type E
4500 7'-4" x 9'-6½" F 5'-8" x 7'-9½" Two-speed 4'-0"/4'-6" S Safety beam required per
OSHA 1926.502 7
4500 7'-4" x 10'-9¼" F/R 5'-8" x 7'-10" Two-speed 4'-0"/4'-6"
5000 7'-4" x 10'-2" F 5'-8" x 8'-5" Two-speed 4'-0"/4'-6" T Max travel possible: 60'-0"
5000 7'-4" x 11'-4¾" F/R 5'-8" x 8'-5½" Two-speed 4'-0"/4'-6" X Standard jack hole depth:
Travel + 6'-0"
5000H 7'-4" x 10'-9" F 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
ENDURA 27
endura MRL
controllers
Perspective view
8" min.
required Building power
28 ENDURA
Single-car
Single car A
configurations Power
Controller
Unit
Power unit A B C 10
Door height Room height
Submersible (large) 7'-2" 7'-1½" 4'-0" Min 7'-0" Min 7'-6" Disconnect
switch
Dry (large) 9'-10" 5'-6" 4'-0" Min 7'-0" Min 7'-6" B (by others)
C Single-car
with dry unit
D
Dual car Dual-car
configurations
Controller
Power
Room Unit
Power unit D E F 10 Door height
height
Submersible (large) 10'-5½" 10'-5½" 4'-0" Min 7'-0" Min 7'-6" E
Controller
Disconnect Power
switch Unit
Dry (large) 14'-7" 7'-0¾" 4'-0" Min 7'-0" Min 7'-6" (by others)
F Dual-car
with dry unit
Endnotes
Dimensional data shown is for both seismic and nonseismic conditions and complies with current ASME A17.1 and CSA
B44 Safety Code for Elevators. Local codes may vary from the national codes. Consult your TK Elevator representative
for details.
1
5'-0" min. pit is required for additional travel. Travel above 12'-8"
A 6
Local codes may impact pit depth minimums.
(1-Stage) or 23'-2½" (2-Stage) or 33'-6½" (3-Stage) requires additional 7
rovided and installed by others, as directed by your TK Elevator
P
pit and/or overhead by adding 1" for every 1" (1-Stage) or 2" (2-Stage)
representative. Clear overhead is shown to the bottom of the safety
or 3" (3-Stage) of additional travel. Max increase 2'-0" allowed in
beam.
overhead. Max travel can be limited by gross load on jack. Local
codes may impact pit depth minimum that will affect extended travel. 8
or service cars (4500 and 5000 lbs capacity) with optional 4'-6"
F
Contact your local representative for max and min travel details. two-speed side opening door, the hoistway width becomes 8'-2"
for below-ground and 1- and 2-stage above-ground jack types and
2 In areas where a 7" deep pit ladder is required, additional hoistway
increases to 8'-4" for a 3-stage above-ground jack type. The hoistway
width or wall pocket will be required.
width must increase an additional 10" if front and rear configuration
3 This capacity is not available with center opening doors. with the same hand doors (catty-corner) are used.
4 To meet the requirements of IBC code for 84" stretchers, a 4'-0" 9
For multiple elevators: Add 4" for a divider beam between hoistways.
center opening (for 4000 lbs capacity only) or 3'-6" side opening 10
Clear opening
(for 3500 lbs or 4000 lbs capacity) door is required. If a smaller
capacity car needs to be the stretcher capable car, contact your local Illustrations and images in this brochure may differ from the installed
representative for more information. product. Consult your local representative for more information.
5
imension shown is based on suspended ceiling design. An increase
D
in cab height will result in an increase in overhead requirements.
For above-ground, front and rear opening applications, the cab height
is limited to 7'-4".
ENDURA 29
Our core principles
We deliver.
Reliable and high-quality products,
services and solutions with precision
and a superior cost-benefit ratio.
We innovate.
We understand. We strive to find
We listen, make suggestions, technology and business
and co-develop with solutions that cater to
our customers. future customer needs.
MOVE
BEYOND
We are leading the way. We build on
We act with foresight and a strong experience.
solution oriented mindset to Our expertise is based
progress our customers, on over 40 years of
employees and other stakeholders. engineering competence.
30 ENDURA
YOUR INNOVATION
PARTNER
elevators and escalators under maintenance countries of customers
1,500,000 100+
employees
50,000+
service available for customers locations
24/7 1,000+
service technicians
25,000+
Key
Comes standard Available Not available FPM Feet per minute
See endnotes on page 29.
LBS Pounds
ENDURA 31
Suite 500
www.tkelevator.com/us
TK Elevator Corporation
788 Circle 75 Parkway SE
All illustrations and specifications are based on information in effect at time of publication approval.
TK Elevator reserves the right to change specifications or design and to discontinue items without prior notice or obligation.
© 2023 TK Elevator Corporation. CA License #C11-651371 | 29903-2 | endura brochure