Eurosets Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

OEM

C A T A L O G U E
CONNECTORS pag. 3

FILTERS pag. 5

CAPS pag. 11

TUBING pag. 12

TUBING ORGANIZER pag. 14

HEAT EXCHANGER pag. 15

VALVES pag. 18

BAGS pag. 19
2
PORT 3 CONNECTORS
Y CONNECTORS
Quality Of Materials The polycarbonate material gives high tensile
PORT 1
strength resistance.
Emocompatibility The completely smooth and radial internal
surfaces prevents from the risk of damaging the cells.
Perfect Coupling The external coupling surface of the connector
without joints grants a perfect coupling with tubes and avoids leaks.
Safety For the L.L. versions the luer is obtained from moulding and
not subsequently assembled in order to prevent any possible leaks.
PORT 2
Note: All type of connectors can be available PC (Phosphorylcholine)
coated, with AGxxxx/V (instead of EUxxxx/V).
MOQ: 1000 pcs.
Y CONNECTORS
CODE PORT 1 PORT 2 PORT 3 LUER
EU3300/V 1/4” 3/8” 1/4” no
EU3301/V 3/8” 3/8” 1/4” yes
EU3302/V 1/4” 1/4” 1/4” no
EU3303/V 3/8” 3/8” 3/8” no
EU3304/V 1/2” 1/2” 1/2” no
EU3305/V 3/16” 3/16” 3/16” no
EU3306/V 1/4” 1/4” 3/8” no
EU3307/V 3/8” 3/8” 1/2” no
EU3308/V 1/4” 3/8” 3/8” no
EU3309/V 3/8” 1/2” 1/2” no
EU3310/V 1/4” 1/4” 1/4” yes
EU3311/V 3/8” 3/8” 3/8” yes
EU3312/V 1/2” 1/2” 1/2” yes
EU3313/V 1/4” 3/8” 1/4” yes
EU3314/V 1/4” 1/4” 3/8” yes
EU3315/V 3/8” 3/8” 1/2” yes
EU3316/V 1/4” 3/8” 1/2” no
EU3317/V 3/8” 1/2” 1/2” yes
EU3337/V 3/16” 3/16” 1/4” no
EU3338/V 3/16” 3/16” 1/4” yes
EU3339/V 1/4” 3/8” 3/8” yes
EU3343/V 3/16” 3/16” 3/16” yes
EU3344/V 1/4” 3/8” 1/2” yes
EU3351/V 1/4” 1/2” 1/2” no
EU3353/V 3/8” 3/8” 1/4” no
EU3355/V 1/4” 1/2” 1/2” yes

CONNECTORS ADAPTERS
CODE PORT 1 LUER PORT
EU3400/V 1/4” LUER
EU3401/V 3/8” LUER
EU3402/V 1/4” LUER LOCK
EU3403/V 3/8” LUER LOCK
3
STRAIGHT CONNECTORS
PORT 1

PORT 2

Note: All type of connectors can be available PC (Phosphorylcholine) coated,


with AGxxxx/V (instead of EUxxxx/V).
MOQ: 1000 pcs.

STRAIGHT CONNECTORS AND SPIKE


CODE PORT 1 PORT 2 LUER MOQ
EU3318/V 1/4” 1/4” no
EU3319/V 3/8” 3/8” no
EU3320/V 1/2” 1/2” no
EU3321/V 3/16” 3/16” no
EU3322/V 1/4” 3/8” no
EU3323/V 3/8” 1/2” no
EU3324/V 1/4” 1/2” no
EU3326/V 1/4” 1/4” yes
EU3327/V 3/8” 3/8” yes
EU3328/V 1/2” 1/2” yes
EU3329/V 3/16” 3/16” yes
EU3330/V 1/4” 3/8” yes
EU3331/V 3/8” 1/2” yes
EU3332/V 3/8” 5/8” no
EU3334/V 1/4” 1/2” yes
EU3335/V 3/16” 1/4” no
EU3336/V 3/16” 1/4” yes
EU3341/V 3/8” 5/8” yes
EU3342/V 1/2” 5/8” yes
EU3352/V 1/2” 5/8” no
EU3528 1/4” spike -
EU3527 vented cap for spike - 1000
EU3528 spike alto flusso per tubo 1/4” 1000
EU3105 temperature probe with luer yes 500

4
FILTERS
GAS FILTER
High sterilizing filtering efficiency
Removes batteric particles and aerosol with an efficiency > 99,99999 %
Special materials
acrylic co-polymer hydrophobic/oleophobic sterilizing membrane.
High safety
the materials used prevents from the risk of breaking of membrane due to overpressure.
Low resistance to gas flow
minimal flow 160 l/m at 350 cmH2O

CODE DESCRIPTION MOQ


EU3779 Gas Filter (Bulk version) 100 500

PRE BY-PASS FILTER 0,2 µm


High filtering efficiency
Allows removal of particles class 0,2 µm from the priming solution of the
extracorporeal circulation circuit.
Easy-to-use
The transparent body facilitates priming operations and recovery
of the solution contained in the filter.
Technical and functional characteristics

CODE DESCRIPTION MOQ


EU3875 Pre-by pass Filter 0,2 µm with vent 100
EU3841 Pre-by pass Filter 0,2 µm 100

PRE BY-PASS FILTER


High filtering efficiency
Allows removal of particles class 5 µm from the priming solution of the extracorporeal
circulation circuit.
Easy-to-use
The transparent body facilitates priming operations and recovery of the solution
contained in the filter.
Wide range of versions
The pre-bypass filter is available in 4 versions, to allow connection with every circuit.

CODE DESCRIPTION MOQ


EU3285 Pre-by pass Filter 3/8” x 1/2” 200
EU3286 Pre-by pass Filter 1/4” x 1/4” 200
EU3287 Pre-by pass Filter 1/4” x 3/8” 200
EU3288 Pre-by pass Filter 3/8” x 3/8” 200
5
ARTERIAL FILTERS
SHERLOCK
Efficacy

remains long time in the upper de-bubbling chamber, thus, the “bubble

The blood flow dynamic has been longer employed to deeply decrease
the rheological stress, and the potential blood damage.

Characteristics

Semi Integrated By-pass Version


The innovative semi-integrated by pass version allows the operator to:

CODE DESCRIPTION MOQ


EU3787/V Sherlock Arterial Filter 2 ways 100
EU3788/V Sherlock Arterial Filter with semi integrated by pass 100

Note: The above codes can be available PC (Phosphorylcholine) coated,


with AGxxxx/V (instead of EUxxxx/V).

6
ARTERIAL FILTERS
MINI SHERLOCK
Efficacy

raise up dramatically.
The blood flow dynamic has been longer employed to deeply decrease
the rheological stress, and the potential blood damage.

Characteristics

CODE DESCRIPTION MOQ


EU3748/V Mini-Sherlock Arterial Filter 100

Note: The above code can be available PC (Phosphorylcholine) coated,


with AGxxxx/V (instead of EUxxxx/V).
ARTERIAL FILTERS
BABY SHERLOCK
Efficacy

The blood flow dynamic deeply decrease the rheological stress,


and the potential blood damage.

Characteristics

CODE IN/OUT CONNECTIONS MOQ


EU5545/V 1/4”-1/4” 100
EU5544/V 3/8” - 3/8” 100

Note: The above codes can be available PC (Phosphorylcholine) coated,


with AGxxxx/V (instead of EUxxxx/V).
BLOOD REINFUSION FILTERS
GOCCIA

CODE DESCRIPTION MOQ


EU3047/B Goccia Filter 25 µm with 1/4” outlet male connector 100
EU3048/BULK Goccia Filter 40 µm 100
EU3051 Goccia Filter 40 µm with Drip Chamber 100
EU3056 Goccia Filter 25 µm with Drip Chamber 100
EU3139 Goccia Filter 25 µm (B) without 1/4” outlet male connector 100
EU3799 Goccia Filter 40 µm IN-OUT 1/4” - 1/4” 100

9
CARDIOPLEGIA FILTERS
High filtering efficiency
Allows removal of pollutants larger than 0,2 µm from the
cardioplegic solution.

Special Materials
Acrylic co-polymer filtering membrane with nylon support
and polyester screen.

CODE DESCRIPTION MOQ


EU3290 Cardioplegia Filter 0,2 µm 200

10
VENT CAPS
Sizes

Material
Rigid thermoplastic or elastomeric thermoplastic material.

manufacturing need.

during manufacturing and final use of the product.

CODE DESCRIPTION MOQ


EU3521B/V Cap 1/4 Blue 3000
EU3521G/V Cap 1/4 Green 3000
EU3521P/V Cap 1/4 Pink 3000
EU3521R/V Cap 1/4 Red 3000
EU3521W/V Cap 1/4 White 3000
EU3521Y/V Cap 1/4 Yellow 3000

EU3522B/V Cap 3/8 Blue 3000


EU3522G/V Cap 3/8 Green 3000
EU3522P/V Cap 3/8 Pink 3000
EU3522R/V Cap 3/8 Red 3000
EU3522W/V Cap 3/8 White 3000
EU3522Y/V Cap 3/8 Yellow 3000

EU3523B/V Cap 1/2 Blue 3000


EU3523G/V Cap 1/2 Green 3000
EU3523P/V Cap 1/2 Pink 3000
EU3523R/V Cap 1/2 Red 3000
EU3523W/V Cap 1/2 White 3000
EU3523Y/V Cap 1/2 Yellow 3000

11
TUBING

Legenda
H = 70 Sh
S = 66 Sh
RB4 = 70 Sh
RB5 = 65 Sh
RB6 = 67 Sh

DOP
CODE DESCRIPTION
EU0501 Tube 3.5 x 5.5 RB4 clear
EU0502 Tube 4.8 x 6.8 RB4 clear
EU0505 Tube 4.3 X 6.8 RB6 clear
EU0511 Tube 1/8 x 1/16 RB5 clear
EU0535 Tube 1/4 x 3/32 RB6 6.36 x 11.12 clear
EU0537 Tube 10 x 13 RB 4 clear
EU0777 Tube 3 x 4.5 RB4 70 SHA
EU1186 Tube 1/4 x 1/16 S Yellow line
EU1187 Tube 1/4 x 1/16 S Green Line
EU1188 Tube 1/4 x 1/16 S Red Line
EU1189 Tube 1/4 x 1/16 S Blue Line
EU1190 Tube 3/8 x 3/32 S Neutral
EU1190B Tube 3/8 x 3/32 S Blue Line
EU1190R Tube 3/8 x 3/32 S Red Line
EU1191 Tube 1/2 x 3/32 S Neutral
EU1191B Tube 1/2 x 3/32 S Blue Line
EU1202 Tube 1/4 x 1/16 H Neutral
EU1203 Tube 3/8 x 1/16 H Neutral
EU1239 Tube 2,15 x 5,35 PVC NO DOP 65Sh
EU1285 Tube 3/16 x 1/16 Neutral
EU1299 Tube PVC 1,8 x 3,5 SH 85
EU1383 Tube 1/2 x 3/32 H Neutral
EU1384 Tube 3/8 x 3/32 H Neutral
EU1385 Tube PVC 1 x 2,5 SH 75
EU1450 Tube 1/4 x 1/16 S Neutral
EU1451 Tube 3/8 x 1/16 S Neutral
EU1490 Tube 1/4 x 1/16 H Yellow Line
12
TUBING

EU1492 Tube 1/4 x 1/16 H Red Line


EU1493 Tube 1/4 x 1/16 H Blue Line
EU1499 Tube 1/4 x 1/16 60Sh Neutral
EU1559 Tube 3/8 x 1/16 Tygon S-50-HL
EU1560 Tube 1/2 x 3/32 60Sh Neutral
EU1657 Tube 3/8 x 3/32 60Sh Neutral
EU1660 Tube 2,15 x 5,35 PVC 84Sh
EU1687 Tube 1/2 x 3/32 S CRYSTAL
EU1688 Tube 3/8 x 3/32 S CRYSTAL
EU1689 Tube 1/4 x 1/16 S CRYSTAL

DOP FREE
CODE DESCRIPTION
EU0506 Tube DOP Free 1,8 x 3,5 85SH
EU0504 Tube DOP Free 1/4 x 3/32 RB6
EU0518 Tube DOP Free 3/8 x 1/16 H
EU0522 Tube DOP Free 1/4 x 1/16 Green
EU0523 Tube DOP Free 1/8 x 1/16 RB5
EU0530 Tube DOP Free 8 x 12mm
EU0574 Tube DOP Free 3 x 4,5 70SH
EU0592 Tube DOP Free 1,5 x 3 Double
EU0594 Tube DOP Free 3/16 x 1/16 H
EU0598/ND Tube 1.9 x 2.9 RB1/DU NDG 92SHA
EU1174 Tube 1/4 x 1/16 Tygon ND-100-65
EU1175 Tube 3/8 x 3/32 Tygon ND-100-65
EU1292 Tube DOP Free 3,5 x 5,5 RB4
EU1293 Tube DOP Free 4,8 x 6,8 RB4
EU1294 Tube DOP Free 4,3 x 6,8 RB6
EU1317 Tube DOP Free 1/4 x 1/16 H
EU1317B Tube DOP Free 1/4 x 1/16H Blue Line
EU1317G Tube DOP Free 1/4 x 1/16H Green Line
EU1317R Tube DOP Free 1/4 x 1/16H Red Line
EU1317Y Tube DOP Free 1/4 x 1/16H Yellow Line
EU1318 Tube DOP Free 3/8 x 3/32 H
EU1318B Tube D.F.3/8 x 3/32 H Blue Line
EU1318R Tube D.F.3/8 x 3/32 H Red Line
EU1319 Tube DOP Free 1/2 x 3/32 H
EU1675 Tube DOP Free 1/2 x 3/32 S 63 SH
EU1676 Tube DOP Free 1/4 x 1/16 S 63 SH
EU1677 Tube DOP Free 3/8 x 3/32 S 63 SH
EU1684 Tube D.F.1/2 x 3/32 H CRYSTAL
EU1685 Tube D.F.3/8 x 3/32 H CRYSTAL
EU1686 Tube D.F.1/4 x 1/16 H CRYSTAL

Note: The above codes can be available PC (Phosphorylcholine) coated, with AGxxxx/V (instead of EUxxxx/V). 13
TUBING ORGANIZER
High Flexibility

tubes flexibility on the sterile field, preventing possible kinking

Wide Range Available

according to the operators need.

CODE DESCRIPTION MOQ


EU3723 5 clips tubing organizer 100
EU3727 6 clips tubing organizer 100
EU3729 7 clips tubing organizer 100

14
HEAT EXCHANGER
Performance
Thanks to its patented geometry it has high efficiency;
Stainless steel has a higher heat exchange coefficient

a smaller heat exchange area with stainless steel than


polyurethane.

the number of pipes has been chosen for reducing the


blood side pressure drop and optimizing the heat
exchange area.
2O2 migration from water side to blood side.

Debubbling
- MISTRAL
ble. We patented the internal geometry with a special
stopcock that allows the priming solution to push the air

Biocompatibility

Compactness
The smaller the foreign surface in contact with blood , the smaller is the contribution to the
patient inflammatory response

Technical Data

CODE DESCRIPTION MOQ


EU5527/V Mistral Cristalloid Cardioplegia 18
EU5509/V Mistral Blood Cardioplegia 18
EU2185/P Plastic Holder for Mistral 1

15
HEAT EXCHANGER
High thermal efficiency thanks to: counter-current exchange
between blood/cardioplegic liquid and water;
Heat exchange surface is made from stainless steel.

thermal exchange.

The blood section has inside an integrated pressure column

the device.

De-bubbling chamber: With 120 µm bubble trap filter for the

The polycarbonate body provides clear visibility of blood flow,


thus any potential bubbles are immediately visible and can be
eliminated; VISION

CODE DESCRIPTION MOQ


EU3064 Vision heat exchanger 20
EU3154 Holder for heat exchanger M1 1

16
HEAT EXCHANGER

For the best biocompatibility of the device.

SPIRAL

CODE DESCRIPTION MOQ


EU3163 Aluminium Spiral 50
EU3174 Stainless steel spiral 50
EU3266 Pediatric aluminium spiral 50
EU3241 Pediatric stainless steel spiral 50
VALVES
Description

aspiration from the intracavitary blood coming from the operating field.
The trivalent valve is made up of two sealed plastic bodies.
A cylindrical-shaped silicone valve with one duck beak-shaped end is
positioned inside it.
Thanks to the shape of the duck bill silicone valve positioned inside it,
the trivalent valve guarantees that the blood passes through it in one
direction only and absolutely prevents air from passing through in the
opposite direction.
The cylindrical part of the silicone valve positioned inside the trivalent
valve is attached to the polycarbonate wall of the valve in which there is
a cylindrical hole.
Thanks to its particular configuration, in the event that the duck bill

the valve deforms to allow a small amount of blood to flow out of the
device through dedicated holes thus reducing the excessive positive
pressure.

flow into the device, immediately bringing the negative pressure back to physiological values.

Connections/Features

The positive pressure is reduced when it reaches approximately 200 mmHg.


The negative pressure is increased when it reaches approximately -300 mmHg.

CODE DESCRIPTION MOQ


EU3823 Trivalent 1/4”-1/4” valve 500
BAGS
VENOUS BAGS

CODE DESCRIPTION MOQ


EU5003B/V VVR1800 Venous Bag 1800 ml 100
AG5003B VVR1800 Venous bag 1800 ml PC (Phosphorylicholine) coated 100
AG3042 Coated Venous Bag 800 ml (fig. 1) 100

(fig. 1)
19
BAGS
VENOUS BAGS
CODE DESCRIPTION MOQ
EU3040 Venous Bag 8 (fig. 2) 150
EU3042 Venous Bag 800 ml (fig. 3) 100
EU3053 Venous Bag 1300 ml (fig. 4) 100
EU3073 Paediatric Venous Bag (fig. 5) 150
EU3096 Venous Bag 165 ml (fig. 6) 100
EU3110 Venous Bag 800 ml M1 (fig. 7) 80
EU3212 Venous Bag 5 Ports (fig. 8) 50
EU3221 Venous Bag (fig. 9) 100

(fig. 2) (fig. 3)

(fig. 4)

20
BAGS

(fig. 6)

(fig. 5)

(fig. 7)

(fig. 8) (fig. 9)

21
TRANSFER BAGS
GRADUATED BAGS
CODE DESCRIPTION MOQ
EU3072 Blood Bag 2000 ml W/Vent Tube (fig. 10) 100
EU3041/ND Graduated Bag 1 Lt No DOP (fig. 11) 250
EU3058/ND Graduated Bag 2 Lt No DOP (fig. 12) 250
EU3118/ND Graduated Bag 1 Lt - 5 Ports (fig. 13) 50
EU3291/ND Bag 1Lt with Stopcock No DOP (fig. 14) 100
EU3298 Bag Transfer with Filter (fig. 15) 100

(fig. 10)

(fig. 11)

(fig. 12)

22
(fig. 13)

(fig. 14)

(fig. 15)

23
BAGS
CARDIOPLEGIA BAGS
CODE DESCRIPTION MOQ
EU3052 Cardioplegia Bag 1Lt 3 valves (fig. 16) 250
EU3113 Cardioplegia Bag 3 Lt 4 Valves (fig. 17) 150
EU3109 Cardioplegia Bag 3 Lt Graduate (fig. 18) 150
EU3721/ND Cardioplegia Bag 1700 ml No DOP (fig. 19) 100
EU3745/ND Cardioplegia Bag 1,2 Lt 5 Valves (fig. 20) 250

(fig. 16)
(fig. 17)

(fig. 18)

(fig. 19) (fig. 20)

24
25
health at heart

eurosets.com

Rev. 1 / 2018

© Copyright 2018 by Eurosets S.r.l. - Catalogue, products, pictures may differentiate from the actual product appearance. Specifications are subject to change without prior notice.

26

You might also like