Dear Partners,
Structural fire protection can save lives and maintain Experience from the construction industry and impul-
infrastructure in the event of a fire. Our comprehensive ses from our close exchange with customers and other
fischer FireStop product portfolio makes an important industry experts are continuously incorporated into the
contribution to this. The solutions effectively prevent further development of our FireStop portfolio. We are
the spread of fire, smoke and toxic gases and thus therefore always happy to receive your suggestions
far-reaching disasters in the event of fire. The assess- and ideas.
ments and approvals of our FireStop products in We hope you enjoy planning and installing our FireStop
accordance with European and international standards products!
give you peace of mind when using them.
For simple and complex applications in construction
projects, the fischer range has the right, easy-to-
assemble and efficient system solution. In this way,
penetrations of any media lines can be effectively
sealed off, curtain walls and VHF (ventilated curtain
walls) can be safely constructed and construction joints Christian Knoll
can be securely sealed. Managing Director fischer SystemTec
From planning and design to training and the installa-
tion of FireStop solutions on site, we also support you
with numerous services. As a strong partner for passive
fire protection, we are at your side with help and advice
in all construction phases until the successful comple-
tion of the project.
For effective sealing against fire, smoke and toxic
gases, the new FireStop catalogue provides you with an
overview of our current products and services. Further
information and details, such as installation instruc-
tions, calculation tables and an index for approvals and
tests, also support you in selecting the most suitable
solution.
3
Brand, safety and sustainability
Award 2015
Exellence in
Operations
CE
International approvals characterise many of
our products.
4
fischer catalogue FireStop
Deutscher
Nachhaltigkeitspreis 2020
SIEGER
Großunternehmen
5
Innovations
that inspire professionals.
Content
Introduction 8 Chapter 1
Basics 64 Chapter 3
Service 74 Chapter 4
7
1
1Introduction 1
FireStop in practice 10
9
1
15
16
3
1
13
6
11
12
10
14
7
fischer catalogue FireStop
FireStop
Applications.
1 2 3
5 6 7
9 10 11
13 14 15
12
fischer catalogue FireStop
4
FiAM (US) Intumescent Acoustic Mastic 16, 19
FCID
FCPS Coated Panel System 51
16
FFSC FireStop Compound 53
FireStop Foam 61
FCPS/FiAM/TDW
13
2
2 2
FireStop Assortment
Intumescent Acoustic Mastic FiAM 16 Fire Collar FFC 43
15
Intumescent Acoustic Mastic FiAM · FireStop Assortment
Applications Advantages
· Metallic pipes: 13“ (325 mm) · Water based · Approved for infinite linear gap length
· Cable trays: 18“ x 2“ (450 x 50 mm) · Low VOC · Halogen and solvent free
· Cable bunches: 4“ (100 mm) · Movement capability ± 25 % · Paintable and excellent slump characte-
· Linear joints: flexible and rigid construc- · Excellent acoustic properties ristics
tion elements
· Joints between FCPS coated panel
system
CE ·
·
Rigid floor and wall constructions
Masonry
emulsion.
· It has a fire resistance of up to 5 hours
· Concrete when used in construction joints and
ETA-20/1065 · Timber services in both vertical and horizontal
ETA-20/1064
· Steel applications.
EN ISO 10140
EN 1026 · FCPS System · When exposed to fire, it reacts to form
EN 1366-3 a highly insulative char that slows down
EN 1366-4
ASTM E 84 (UL 723) heat transfer and provides a barrier to
ASTM E 1966 (UL 2079) fire.
· It is suitably compatible in a variety of
materials, and is utilised within the FCPS
which is designed to seal large openings
in fire rated floors and walls.
Installation FiAM
16
Intumescent Acoustic Mastic FiAM · FireStop Assortment
Technical data
B
A
Application data
17
Intumescent Acoustic Mastic FiAM · FireStop Assortment
18
Intumescent Acoustic Mastic FiAM US · FireStop Assortment
Applications Advantages
· Linear joints: flexible and rigid construc- · Water based · Age resistant
tion elements with dynamic movement · Excellent acoustic properties · Smoke resistant
· Metallic pipes and ducts · Low VOC · Excellent adhesion
· Insulated metallic pipes · Halogen and solvent free · F-rating up to 3 hrs
· Conduits · Various applications with two products · T-rating up to 3 hrs
· Cable and cable bunches only
· Cable trays
Installation FiAM US
19
Intumescent Acoustic Mastic FiAM US · FireStop Assortment
Technical data
Languages on the cartridge Contents Adapted for Sales unit
Item no. [ml] [pcs]
Item
FiAM US 546487 DE, EN, ES, TR 310 – 1
FiAM US 19 liter bucket 554934 – – – 1
KPM 2 Plus 053117 – – FiAM 310, FFRS 310, UFS 310, FiGM 310 1
2
Technical data
B
A
Application data
20
Fire Rated Silicone Sealant FFRS · FireStop Assortment
Applications Advantages
· General construction joints in floor to · Excellent acoustic properties · Halogen and solvent free
floor, wall to wall, floor to wall and head of · Primerless adhesion to most substrates · Excellent slump characteristics
wall up to 2.36‘‘ (60 mm) · Approved for infinite linear gap length · Movement capability ± 7.5 %
· Internal and external applications
CE
EN 1026
EN 1366-4 · Masonry that can provide up to 5 hours fire resis-
· Steel tance when used in construction joints.
ETA-20/1102 · Timber · It provides primerless adhesion to a
wide range of porous and non-porous
substrates.
Installation FFRS
21
Fire Rated Silicone Sealant FFRS · FireStop Assortment
Technical data
Ap- Languages on the cartridge Contents Adapted for Sales unit
pro-
val
Item no. ETA [ml] [pcs]
Item
FFRS White 310 ml 512374 ● DE, FR, EN, IT 310 – 1
2 FFRS White 310 ml 538140 ● DK, FI, SE, NO 310 – 1
FFRS White 310 ml 538138 ● TR, PT, ES, NL 310 – 1
FFRS White 310 ml 538139 ● PL, SK, CZ, HU 310 – 1
KPM 2 Plus 053117 – – – FiAM 310, FFRS 310, UFS 310, FiGM 310 1
Technical data
B
A
Application data
22
Fire Rated Silicone Sealant FFRS · FireStop Assortment
23
Rapid Fire Seal RFS 640 · FireStop Assortment
Applications Advantages
· Curtain wall/slab edge: 8“ (200 mm) · Water based · Spray or brush applied
· Head of wall: 4“ (100 mm) · Flexible set · Excellent smoke seal
· General construction joints: 8“ (200 mm) · Contains mould growth inhibitor · Water resistant
· Cable tray: 24“ x 4“ (600 mm x 100 mm) · Freeze - thaw capabilities · Asbestos and solvent free
· Steel pipes: 8“ (200 mm) · Paintable · Can be used for internal applications and
· Accelerated age and humidity tested for conditions where dynamic movement
· Low VOC may occur.
24
Rapid Fire Seal RFS 640 · FireStop Assortment
Technical data
Contents Colour Sales unit
Item no. [l] [pcs]
Item
RFS 640 516539 19 red 1
Technical data
25
Rapid Fire Seal RFS 640 · FireStop Assortment
Application data
26
Fire I Barr ElastoSeal FFB-ES · FireStop Assortment
Applications Advantages
· Linear joints in construction elements up · Openings up to 20“ (500 mm) wide · Air permability
to 20“ (500 mm) wide · Movement capabilities of 25 % · Acoustic performance
· Floor to floor · Working temperature between -10 °C and · 80 kg/m³ stone wool base
· Wall to wall 95 °C · 2.5 mm WFT required
· Head of wall · Can be spray or brush applied
· Bottom of wall
· Curtain wall
· Cabel / cabel trays
· Metallic pipes
CE ·
·
Rigid floor and wall constructions
Concrete
coating, which has been designed to
provide smoke and fire protection on
· Masonry construction joints in both vertical and
ETA-20/1103 horizontal applications.
ETA-20/1101
· Developed for use on 80 kg/m³ stone
EN ISO 10140
EN 1026 wool base.
EN 1027 · Once applied, it prevents the passage of
EN 1364-4
EN 1366-3 fire and smoke and can contribute to the
EN 1366-4 acoustic value of a structure between fire
rated compartments giving a fire resis-
tance for up to EI 240.
Installation FFB-ES
27
Fire I Barr ElastoSeal FFB-ES · FireStop Assortment
Technical data
Ap- Content Sales unit
pro-
val
Item no. ETA [kg] [pcs]
Item
FFB-ES/White 520753 ● 20 1
2 FFB-ES/Grey 520755 ● 20 1
FFB-ES/Red 520756 ● 20 1
Technical data
Application data
28
Universal FireStopping Sealant UFS · FireStop Assortment
Applications Advantages
· Metallic services: steel and cast iron 20“ · Water based · Paintable
(500 mm) - copper 6“ (150 mm) · Flexible set · Accelerated age and humidity tested
· Non metallic service: PVC 2“ (51 mm · Contains mould growth inhibitor · Low VOC
open) 3“ (75 mm closed) · Freeze - thaw capabilities · Excellent acoustic properties
· Insulated service: 20“ (500 mm)
· Construction joints: 4“ (100 mm)
· HVAC 100“ (2500 mm)
· Cable bunches 4“ (100 mm): busway 27“
(686)
29
Universal FireStopping Sealant UFS · FireStop Assortment
Technical data
Languages on the cartridge Contents Contents Adapted for Sales unit
Item no. [ml] [l] [pcs]
Item
UFS 310 5165381) DE, FR, EN, NL 310 – – 12
UFS 19 liter bucket 533889 – – 19 – 1
KPM 2 Plus 053117 – – – FiAM 310, FFRS 310, UFS 310, FiGM 310 1
1) Curing rate is dependant on substrate, air humidity and weather conditions.Movement capability depends on UL listed system and configuration.
Technical data
30
Universal FireStopping Sealant UFS · FireStop Assortment
Application data
31
Intumescent Graphite Mastic FiGM · FireStop Assortment
Applications Advantages
· Metallic pipes: 6“ (159 mm) · Low VOC · Halogen and solvent free
· Non-metallic pipes: 5“ (125 mm) · Excellent acoustic properties · Excellent slump characteristics
· Cable bunches: 1“ (21 mm)
· Insulated service: 6“ (159 mm)
· Construction joints: 1“ (25 mm)
· Mixed services
CE ·
·
Masonry
Steel
le acrylic emulsion containing a high
pressure intumescent graphite, which is
· Timber used to seal service penetrations in both
ETA-20/1105 vertical and horizontal applications.
EN ISO 10140 · It can expand up to 20 times its own volu-
EN 1026
EN 1366-3
me and cures to form a resilient, flexible
fire seal.
32
Intumescent Graphite Mastic FiGM · FireStop Assortment
Technical data
Ap- Languages on the cartridge Contents Adapted for Sales unit
pro-
val
Item no. ETA [ml] [pcs]
Item
FiGM 310 ml 508765 ● DE, FR, EN, IT 310 – 1
FIGM 310 ml 538147 ● TR, PT, ES, NL 310 – 1
FiGM 310 ml 538148 ● PL, SK, CZ, HU 310 – 1
FiGM 310 ml 538149 ● DK, FI, SE, NO 310 – 1
KPM 2 Plus 053117 – – – FiAM 310, FFRS 310, UFS 310, FiGM 310 1
Technical data
33
Intumescent Graphite Mastic FiGM · FireStop Assortment
Application data
34
Foam Barrier System PLUS · FireStop Assortment
Applications Advantages
· Metallic pipes up to 8“ (203 mm) · Easy access for difficult to reach ope- · Resistant to damp
· Insulated metallic pipes nings · Re-enterable and repairable
· Conduits · Low VOC · Excellent adhesion
· Cable and cable bunches · Various applications with two products · No backing material required
· Cable trays only · F-rating / E-Integrity rating up to 2 hours
· Mixed multiple penetrations · Age resistant · T-rating / EI-Insulation rating up to 2
· Smoke resistant hours
CE · Masonry
· Flexible wall
expanding sound, smoke and firestop-
ping seal for hard to reach locations
which expands to up to 5 times of its
ETA-17/0845 volume.
EN 1366-3 · FBB are highly elastic mouldable blocks.
ASTM E 84 (UL 723)
· FIB is a glass fiber reinforced intume-
ASTM E 814 (UL 1479)
EN 13501-1 scent wrap to enhance the insulation
value of ETA applications.
· Tested in accordance with ASTM E 814
(UL 1479), ASTM E84 (UL 723) as well as
EN 1366-3, EN 13501 the Barrier System
PLUS allows an easy application which
saves time and costs on site.
35
Foam Barrier System PLUS · FireStop Assortment
Installation FBS
FIRE STOP
2
Installation FBB
Technical data
Ap- Languages on the cartridge Contents Dimensions Sales unit
pro-
val
Item no. ETA [ml] [mm] [pcs]
Item
FBS-UL 544079 – – 380 – 6
FBB-UL FireStop Block 544083 – – – 200 x 130 x 60 12
FBS-EN 544084 ● DE, FR, EN, IT 380 – 6
FBS-EN 544085 ● DK, FI, SE, NO 380 – 1
FBS-EN 544086 ● PL, SK, CZ, HU 380 – 1
FBS-EN 544087 ● TR, PT, ES, NL 380 – 1
FBB-EN FireStop Block 544088 ● – – 200 x 144 x 60 4
FIB Insulating Bandage 544089 – – – 5000 x 150 1
FFBD Foam Barrier Dispenser 544090 – – – – 1
Temperature resistance ≤ 80 °C
Yield ≤ 1.9 l
Curing time approx. 90 s
Shelf life 12 month
Storage temperature + 5 °C to + 30 °C
Colour reddish brown
36
Foam Barrier System PLUS · FireStop Assortment
Temperature resistance ≤ 80 °C
Construction material class B2 as per DIN 4102
Accoustic performance 45.5 - 68
Colour reddish brown
Application data - UL
Blank opening Metallic pipes and conduits Cables/Cable trays Insulated metall pipes Mixed penetrations
Max. possible sizes of Max 32 x 32 inch Max 8 inch (203 mm) Max 24 inch (610 mm) wide Max 8 inch (203 mm) dia- see listed system
penetrations (813 x 813 mm) diameter by max. 6 inch (152 mm) meter with 1 inch (25 mm)
deep cable tray insulation
Barrier System PLUS UL C-AJ-0158, W-L-0052 C-AJ-1669 C-AJ-3341, C-AJ-4110, C-AJ-5383 C-AJ-8260, C-AJ-8261
W-L-4091
37
Intumescent Pipe Wraps FiPW · FireStop Assortment
Applications Advantages
· Non-metallic pipes · Efficient and effective for sealing of pipe · Economical solution
· Polyvinyl Chloride PVC openings in floors and walls · Up to 2 hours fire resistance
· Chlorinated Polyvinyl Chloride cPVC · Easy to fit · Asbestos and halogen free
· Medium-density Polyethylene MDPE · Moisture resistant · Available on a roll for more flexibility in
· High-density Polyethylene HDPE · No mechanical fixing required pipe diameters
· Acrylonitrile Butadiene ABS
Installation FiPW
38
Intumescent Pipe Wraps FiPW · FireStop Assortment
FIRE STOP
2
Technical data
Ap- Fits pipe-Ø Fire rating Sales unit
pro-
val
[mm] [hours]
Item no. ETA [pcs]
Item
FiPW E / 2 mm (25 meter roll) 539608 ● 30 - 250 up to 2 1
Technical data
State solid
Colour black inner component in outer foil carrier
Odour odourless
Density 1.3 kg/m³
Expansion ratio 1 : 25
Significant expansion occurs at temperature > 180 °C
Storage temperature + 5 °C to + 35 °C
Thickness 2 mm
European Technical Assessment ETA-21/1061
CE marking 2531-CPR-CXO10326
Application data
39
Intumescent Wrap Strip FiWS · FireStop Assortment
Applications Advantages
· Non-metallic service: PVC 14“ (355 mm), · Efficient and effective for sealing of pipe · No mechanical fixing required
cPVC 8“ (203 mm), ABS 6“ (152 mm), openings in floors and walls · Economical solution
FRPP 4“ (102 mm) · Easy to fit · Up to 4 hours fire resistance
· Insulated service: Steel 10“ (254 mm), · Moisture resistant · Asbestos and halogen free
Iron 10“ (254 mm), Copper 4“ (102 mm), · Freeze-thaw characteristics
Glass fibre 3“ (75 mm), AB/PVC flexible
foam 1“ (25 mm)
· Cable bunches: 3“ (76 mm)
Certificates Functioning
40
Intumescent Wrap Strip FiWS · FireStop Assortment
FIRE STOP
Technical data
Dimensions Sales unit
BxLxH
Item no. [pcs]
Item
FiWS-2 531397 50 mm x 6 mm x 5.48 m / 2˝x 1/4˝ x 18˝ 1
Universal Collar 2 536053 51 mm x 15 m / 2“ x 50 ft 1
Technical data
State solid
Odour odourless
Density approx. 1.3 kg/m³
Expansion ratio 1 : 40
Significant expansion occurs at temperature > 190 °C
Max. recom. pipe-Ø < 355 mm
Flame spread (ASTM E 84 - UL723) 5
Smoke index (ASTM E 84 - UL723) 5
Colour black
41
Intumescent Wrap Strip FiWS · FireStop Assortment
2
Both sides of the wall
Botttom of floor
Application data
42
Fire Collar FFC · FireStop Assortment
Applications Advantages
· Non-metallic pipes like PVC, HDPE, · Easy retrofit at any time · Pre-fixed attachment lugs
MDPE, ABS of various sizes through fire · Water resistant · Fold back tag for secure fixture around
rated walls and floor assemblies · No minimum annular service required pipe
· Flexible and rigid wall constructions · FFC is a powder coated cylindrical steel
43
Fire Collar FFC · FireStop Assortment
Technical data
Ap- Fits pipe-Ø Sales unit
pro-
val
[mm]
Item no. ETA [pcs]
Item
FFC 2/30-32 052456 ● 30 - 250 1
FFC 2/38-40 052480 ● 38 - 40 1
FFC 2/55 052481 ● 55 1
FFC 2/63 052482 ● 63 1
FFC 2/75 052483 ● 75 1
FFC 2/82 052486 ● 82 1
FFC 2/90 052487 ● 90 1
FFC 2/110 052488 ● 110 1
FFC 2/125 052489 ● 125 1
FFC 2/160 052500 ● 160 1
FFC 2/200 052501 ● 200 1
Technical data
State solid
Odour odourless
Fire resistance up to 4 hours
Available sizes > 30 mm and max up to 200 mm
Significant expansion occurs at temperature > 180 °C
Storage temperature N/a
Shelf life N/a month
Colour black inner component in outer foil carrier
European Technical Assessment ETA-20/1063
CE marking 2531-CPR-CXO10320
44
Cast-in Device FCID Plus · FireStop Assortment
FCID Plus within reinforced concrete floor Installed pipe through FCID Plus device
Applications Advantages
· Sealing and firestopping PVC and HDPE · Quick installation · Cost saving
pipes up to 6˝ (150 mm) · Watertight seal · Reduced foot plate
· Forms holes up to 8˝ (200mm) thick · Higher tolerance · Eco-friendly extension tube
concrete floors. In combination with · Easily extendable · Closer proximity positioning
extension pieces up to additional 4“ · Wider base for further connections · Free of asbestos, solvents and any hazar-
(100mm) possible. · No further collars or wraps required dous ingredients.
· FCID Plus creates recesses in slabs for · Reduce working at heights
lower positioning of soil
· Manifold units in wet room applications
45
Cast-in Device FCID Plus · FireStop Assortment
Technical data
Fits pipe-Ø Height H Sales unit
[mm] H
Item no. [mm] [pcs]
Item
FCiD Plus 50 566285 50/2“ 200/8“ 12
FCiD Plus 75 566286 75/3“ 200/8“ 12
FCiD Plus 100 566287 100/4“ 200/8“ 12
2
FICD Plus 150 566288 150/6“ 200/8“ 6
FCiD Plus 50 extension 566289 50/2“ 100/4“ 6
FCiD Plus 75 extension 566290 75/3“ 100/4“ 6
FCiD Plus 100 extension 566291 100/4“ 100/4“ 6
FCiD Plus 150 extension 566292 150/6“ 100/4“ 6
FCiD Plus 50 Deck adapter 566293 50/2“ – 6
FCiD Plus 75 Deck adapter 566294 75/3“ – 6
FCiD Plus 100 Deck adapter 566295 100/4“ – 6
FCiD Plus 150 Deck adapter 566296 150/6“ – 6
Technical data
State solid
Odour odourless
Shell material Polyethylene
Fire resistance up to 4 hours - BS 476: Part 20 and AS 1530: Part 4
Extension or reduction in height possible Yes
Standard flange width min 154 mm and max 254 mm
Significant expansion occurs at temperature > 190 °C
Shelf life N/a month
Colour black
46
Intumescent Pillows FiP · FireStop Assortment
Applications Advantages
Certificates Functioning
47
Intumescent Pillows FiP · FireStop Assortment
Technical data
Ap- Dimensions Weight per pillow Sales unit
pro-
val
Item no. ETA [mm] [g] [pcs]
Item
FiP/S 516960 ● 330 x 50 x 20 80 1
FiP/Std 533890 ● 330 x 100 x 20 120 1
FiP/M 516959 ● 330 x 200 x 25 230 1
FiP/L 516958 ● 330 x 200 x 45 420 1
Technical data
State solid
Odour -
Expansion -
Significant expansion occurs at temperature > 140
European Technical Assessment ETA-20/1063
CE marking 2531-CPR-CXO10320
Colour black
Estimation quantities
48
Intumescent Putty Pad FiPP · FireStop Assortment
Applications Advantages
49
Intumescent Putty Pad FiPP · FireStop Assortment
Technical data
Dimensions Fire rating Sales unit
[hours]
Item no. [mm] [pcs]
Item
FiPP/I-S 053578 170 x 170 2 1
FiPP/I-D 054757 230 x 170 2 1
FiPP/E-S 506261 155 x 155 2 1
2
FiPP/E-D 506262 210 x 180 2 1
Technical data
50
Coated Panel System FCPS · FireStop Assortment
Mixed penetration through the floor Mixed penetration through the wall
Applications Advantages
· Small and large openings · Approved for light partition walls · Excellent acoustic properties
· Cables/cable trays · Can be installed dry · Asbestos and halogen free
· Air ducts with dampers · No coatback required for services
· Metallic or non-metallic pipes
Certificates Functioning
ISO 10140 · FCPS is a rock fibre core coated with ab-
CE
EN 1366-3
lative sealant FPC for use in both vertical
and horizontal applications.
ETA-20/1062 · It maintains the sound reduction index of
ETA-20/1067 a structure.
· The FCPS will allow additional services to
be added or removed and will accommo-
date thermal and mechanical movement
of services.
· FPC can be used to adhere sections of
FCPS board when jigsaw assembly is re-
quired and can also be used to enhances
smoke and acoustic performance.
Installation FCPS
FIRE STOP
51
Coated Panel System FCPS · FireStop Assortment
Technical data
Ap- Dimensions Content Contents Adapted for Sales unit
pro-
val
Item no. ETA [mm] [kg] [ml] [pcs]
Item
FCPS/50 053252 ● 1200 x 600 x 50 – – – 1
2 FPC/5kg 053253 ● – 5 – – 1
FiAM 310 053011 ● – – 310 – 1
KPM 2 Plus 053117 – – – – FiAM 310, FFRS 310, UFS 310, 1
FiGM 310
Technical data
Application data
52
FireStop Compound FFSC · FireStop Assortment
Mixed penetration through the floor Mixed penetration through the floor
Applications Advantages
· Metallic services with steel and cast iron · Water based · Excellent acoustic proper-ties
pipes · Low VOC · Both vertical and horizontal applications
· Non-metallic services with FiPW intume- · Load bearing · Halogen and asbestos free
scent pipe wrap or FFC pipe collar
· Voids or cavities in floors or walls
· Cable bunches
Certificates Functioning
53
FireStop Compound FFSC · FireStop Assortment
FIRE STOP
Technical data
Ap- Content Sales unit
pro-
val
Item no. ETA [kg] [pcs]
Item
FFSC/20 kg 533247 ● 20 1
Technical data
Application data
By volume
Powder to water ratio
Pourable grade 2.5 : 1
Trowelable grade 3:1
* These are approximate calculations based on 20 kg bags. The coverage does not take into account the percentage of the hole filled with services.
** As a further safety margin, we would recommend that all floor seals with clear areas greater than 1,100 mm x 1,100 mm mus t be reinforced.
Load bearing note: the open area free of services: Thickness of seal ratios for non-reinforced seals given above allow an ample safety margin for normal foot traffic, e.g., loads of two men
plus equipment with a combined weight up to 200 kg.
54
VentiStop Cavity Barrier - FFB-VS · FireStop Assortment
FFB-VS Ventistop installed with Multi-Purpose FFB-VS Ventistop installed with DHM Anchor
Bracket
Applications Advantages
· Horizontal cavities between the inner and · Tested up to 120 minutes integrity and gap
outer construction elements 90 minutes insulation (120 min insulation · Voids up to 450 mm wide
with FFB-VS HP80) utilising the heating · Free of halogens, asbestos, fi bres and
and pressure conditions of EN 1363-1: silica and is non-toxic
2017 and ASFP TGD19: 2014 - Open State · Long life expectancy
Cavity Barriers. · Contributes to green building
· Suitable to close 25 & 50 mm ventilation
55
VentiStop Cavity Barrier - FFB-VS · FireStop Assortment
Technical data
To suit cavity void width Sales unit
Item no. [mm] [pcs]
Item
FFB-VS/25-50 521520 25 - 50 1
FFB-VS/51-100 521521 51 - 100 1
FFB-VS/101-150 521522 101 - 150 1
FFB-VS/151-200 521523 151 - 200 1
FFB-VS/201-250 521524 201 - 250 1
FFB-VS/251-300 521525 251 - 300 1
FFB-VS/301-350 521526 301 - 350 1
FFB-VS/351-400 521527 351 - 400 1
FFB-VS/401-450 521528 401 - 450 1
IMPORTANT: Please provide TOTAL cavity width for your application, excluding an y insulation there might be.
Technical data
To suit cavity void width Sales unit
Item no. [mm] [pcs]
Item
FFB-VS50/51-100 545628 51 - 100 1
FFB-VS50/101-150 545629 101 - 150 1
FFB-VS50/151-200 545630 151 - 200 1
FFB-VS50/201-250 545631 201 - 250 1
FFB-VS50/251-300 545632 251 - 300 1
FFB-VS50/301-350 545633 301 - 350 1
FFB-VS50/351-400 545634 351 - 400 1
FFB-VS50/401-450 545635 401 - 450 1
IMPORTANT: Please provide TOTAL cavity width for your application, excluding an y insulation there might be.
Technical data
Description Foil faced stone wool with a black intumescent leading edge
Fire resistance up to 120 min
Closure time - FFB-VS < 5 min
Activation approx. 180 °C
Expansion pressure approx. 7 N/mm²
Density Stone wool - 90 kg/m³, intumescent 1.3 g/cm ³
Weather resistance Yes
Sag 0%
Open void size 25 - 50 mm
Dimensions 80 mm thick, 1000 mm long mm
Width 30 - 450 mm
Fixing points (brackets or anchor DHM) 300 mm
Colour White/red/silver/black
56
VentiStop Cavity Barrier - FFB-VS · FireStop Assortment
Technical data
To suit cavity void width Colour Fire rating Sales unit
[hours]
Item no. [mm] [pcs]
Item
Multi Purpose Bracket 563201 230 x 25 x 1 (A2) silver N/a 250
Multi Purpose Bracket 551868 390 x 25 x 1 (A2) silver N/a 1
Multi Purpose Bracket 551954 500 x 25 x 1 (A2) silver N/a 1
2
FCI Cassette tray cavity barrier 554125 1200 x 100 x 50 silver N/a 1
57
Cavity FireStop Clad FCFcl · FireStop Assortment
FCFcl Cavity Clad - Vertical application FCFcl Cavity Clad - Horizontal application
Applications Advantages
· Horizontal and vertical cavities bet- · Tested to EN 1366-4 & BS 476 · Superior Level of Sustainability
ween the inner and outer construction · Classification to EN 13501-2, EN 13501-1 · Encased Fibre Migration for Air Plenum
elements · Air Permeability to EN 1026 to 600Pa Use
· Ceiling Cavity Barriers · Acoustic Isolation to EN 10140 to 31dB · Floor & Wall voids up to 590 mm wide
· Under Floor Cavity Barriers
· Slab Edge Barriers
CE
EN ISO 10140
EN 1026
· Curtain wall assemblies piece closed dimension stone wool core.
EN 1366-4 · The product is encased with an alumi-
NFPA 285
num foil face which provides class ‚O‘
ETA-21/1062
rating and exhibits excellent resistance
to smoke.
· The FCFcl Cavity Clad provides a resilient
lateral compression which is required to
ensure a tight fit.
Installation FCFcl
58
Cavity FireStop Clad FCFcl · FireStop Assortment
Installation FCFcl
Technical data
Ap- To suit cavity void width Sales unit
pro-
val
Item no. ETA [mm] [pcs]
Item
FCFcl 75 546210 ● 1200 x 600 x 75 1
FCFcl 100 053046 ● 1200 x 1000 x 100 1
FCFcl 1200 546209 ● 1200 x 1200 x 100 1
IMPORTANT: Please provide TOTAL cavity width for your application, excluding any insulation there might be. FCFcl Cavity Clad shall be cut 5 mm (1/5 in.) or 10 mm (3/8 in.) oversize. * Depen-
ding on design & configuration of the FCFcl Cavity Clad.
Technical data
To suit cavity void width Fire rating Sales unit
[hours]
Item no. [mm] [pcs]
Item
Multi Purpose Bracket 563201 230 x 25 x 1 (A2) N/a 250
Multi Purpose Bracket 551868 390 x 25 x 1 (A2) N/a 1
Multi Purpose Bracket 551954 500 x 25 x 1 (A2) N/a 1
Technical data
59
FireStop Foam · FireStop Assortment
FireStop Foam
A single component filler foam with effective fire resistance
Applications Advantages
· Construction joints in walls and floors · High foam yield · High bond strength
· Insulating and sealing doors and win- · No post shrinkage or expansion · Good adhesion to most building mate-
dows: non-fire rated application · CFC free propellant rials
· Backfilling material only for service · Effective seal against smoke · Excellant acoustic and thermal proper-
penetrations · Rendered, cut, painted or sanded ties
· Filling general voids and cavities: nonfire
rated application
CE
EN 1366-4
· Masonry self expanding polyurethane foam, which
· Steel as backing material has been designed to be self curing
ETA-20/0770 · Timber as backing material via the absorption of moisture from the
atmosphere.
· The foam has excellent adhesion pro-
perties and can adhere to most building
materials. When the foam sets it cures to
a semi-rigid structure, which accommo-
dates low movement and vibration.
60
FireStop Foam · FireStop Assortment
Technical data
Ap- Contents Sales unit
pro-
val
Item no. ETA [ml] [pcs]
Item
FireStop Foam Hand 042757 ● 750 1
FireStop Foam Gun 043712 ● 750 1 2
Technical data
61
Thermal Defense Wrap TDW · FireStop Assortment
Applications Advantages
· Metallic services with steel and cast iron · Remains flexible -10 to +160 · Pre-formed 300 mm roll
pipes · Low VOC · Fast and efficient installation
· General construction joints: wall to floor · High insulation and temperature stability · Remains flexible without aging
to head of wall
· Drywall partitions, connections
· FCPS joints
Certificates Functioning
EN ISO 10140 · TDW is ceramic-based technology of
EN 1366-3
bio-soluble vitreous fibres and flexible
organic builders, and has been designed
to maintain the compartmentalisation of
a fire-rated assembly.
· The unique design of the TDW allows
for movement of services, maintain the
necessary insulation of the services
and prevents temperature, rise of the
services at the cold face. At normal
temperature the TDW remains flexible
and permits thermal and mechanical
movement.
· It provides up to 2 hours integrity and
insulation.
62
Thermal Defense Wrap TDW · FireStop Assortment
Technical data
Dimensions Sales unit
Item no. [mm] [pcs]
Item
TDW 1 531398 300 x 1000 1
Technical data 2
Apperarance white, fibrous material with aluminium foil face
Base material Calcium magnesium silicate fibres
Water solubility N/a
Alufoil thickness 0.25 mm
Storage temperature + 5 °C to + 25 °C
63
fischer catalogue FireStop
64
3
Basics – good to know. 3
Fire prevention 66
65
Fire prevention
Fire prevention is a critical consideration for those who are through a combination of active and passive FireStop sys-
responsible for creating the design, specification and con- tems and, when used in conjunction with each other, provide
struction of new buildings, with consideration in the ongoing a balanced fire protection strategy.
maintenance of occupied premises. Active fire prevention systems are designed to react to the
As the causes of fire vary and are often unpredictable, outbreak of a fire, which is then suppressed with the help of
construction measures are being designed to influence the sprinkler systems, halogen installations, fire extinguishers
formation and spread of fire, smoke and toxic gases, by min- or other proactive mechanical systems. The effects of the
3
imising the available factors needed to create a fire or to limit fire may also be lessened by the removal of smoke from the
the spread of fire once it has started. equation. By including alarms and emergency lighting, active
Effective fire fighting within a building is generally achieved systems also serve to provide escape paths for people inside
through a combination of active and passive FireStop sys- the building.
tems and, when used in conjunction with each other, provide
a balanced fire protection strategy. Passive fire prevention systems
Passive fire prevention is an integral component, which is
Active FireStop systems designed and built in to the fabric of the structure. It is also
Fire prevention is a critical consideration for those who are an essential element of the fire safety of a building. The risk
responsible for creating the design, specification and con- of fire can be minimised by dividing the building into a series
struction of new buildings, with consideration in the ongoing of compartment/cells bounded by fire rated walls and floors.
maintenance of occupied premises. To maintain the firestopping integrity of a compartment/cells,
As the causes of fire vary and are often unpredictable, any gaps, openings, void or channels within the fire rated
construction measures are being designed to influence the walls or floors must be sealed with an approved or certfied
formation and spread of fire, smoke and toxic gases, by min- system to prevent the passage of fire, smoke and toxic
imising the available factors needed to create a fire or to limit gases.
the spread of fire once it has started.
Effective fire fighting within a building is generally achieved
66
Germany: Federal Building Order of extensive research and development, the first edition of
In Germany, the Federal State Building Order is regulated the International Building Code was published in 1997.
at the level of the federal states. Therefore, there are 16 The code was patterned on three legacy codes previously
regional state building codes with their own regulations and developed by the organizations (BOCA, SBCCI, ICBO) that
guidelines. The 2002 Directive Building Code and the 2005 constitute IBC. By the year 2000, ICC had completed the
Directive Guidelines for conduit and ventilation systems form International Codes series. Relevant firestop requirements
the basis for further consideration. The list of the Technical can be found in below mentioned references:
Building Regulations – M-ETB, includes other codes, such as 702 Definitions
the MLAR and the German Ventilation Systems Directive – 704.9 Separation of Vertical Openings - Sprinkler Exception
MLüAR. Once guidelines are adopted into the list at regional 708 Fire Partitions 1 Hour Rating
state level List of Technical Building Regulations–LTB, the 709 Smoke Barriers 1 Hour Rating 3
guidelines become legally binding. 710 Horizontal Assemblies
NFPA 101 Life Safety code: United States 711 Penetrations (General)
Life Safety Code addresses those construction, protection, 711.3.2 Sprinkler Heads Electrical Boxes
and occupancy features necessary to minimise danger to 711.4.1.2 „F“ & „T“ Rating Requirements
life from the effects of fire, including smoke, heat, and toxic 712 Fire-Resistant Joint Systems
gases created during a fire. The Code establishes minimum 712.4 Curtain Wall to Edge of Slab
criteria for the designs of egress facilities, so as to allow
prompt escape of occupants from buildings or, where desira- Other relevant codes from IBC: United States
ble, into safe areas within buildings. The Code also address- The International Building Code and International Residential
es protective features and systems, building services, oper- Code are just a few of the comprehensive I-Codes the Code
ating features, maintenance activities, and other provisions in Council has created. The publications of the codes allow for
recognition of the fact that achieving an acceptable degree easier following from members and allow them to observe
of life safety depends on additional safeguards to provide and study the model code. Some of these codes have spe-
adequate egress time or protection for people exposed to cific practices, such as the International Fire Code and the
fire. Relevant firestop requirements can be found in below International Green Construction Code, or the IGCC. Here is
mentioned references: the current list of I-Codes developed and published by the
8.2.2 Compartmentation Continuity Code Council:
8.2.3.2.4 Penetrations and Openings In Fire barriers International Building Code
8.2.4.4 Penetrations and Openings In Smoke Partitions International Residential Code
8.3.2 Continuity of Smoke Barriers International Fire Code
International Plumbing Code
NFPA 5000 Building Construction and Safety- International Mechanical Code
code International Fuel Gas Code
NFPA 5000 – Building Construction and Safety Code is a International Energy Conservation Code
model building code developed by the National Fire Pro- IBC Performance Code
tection Association. For the most part, the requirements International Wildland Urban Interface Code
for fire stops are the same in NFPA 5000 as they are in the International Existing Building Code
IBC. It also addresses joints between assemblies in a similar International Property Maintenance Code
manner to the IBC. NFPA 5000 states openings must be International Private Sewage Disposal Code
protected by „a system or material capable of restricting the International Zoning Code
transfer of smoke“. It addresses protection for through-pene- International Green Construction Code
trations and membrane penetrations in Section 8.8 using the
same test methods as the IBC. The requirements for F and T Other relevant code
ratings are also the same. Joint systems, including perimeter NFPA is responsible for 300 codes and standards that are
joints at cur tain walls, are addressed in the same manner as designed to minimize the risk and effects of fire by establish-
the IBC. ing criteria for building, processing, design, service, and
installation. Some of the other widely used NFPA codes are:
IBC International Building Code: United States NFPA 70 NEC – National Electrical Code NFPA 96 - Standard
In the Past: The Regional Model codes developed by the for Ventilation Control and Fire Protection of Commercial
Building Officials Code Administrators International (BOCA) Cooking Operations. NFPA 221 - Standard for High Challenge
were used on the East Coast and throughout the Midwest Fire Walls, Fire Walls, and Fire Barrier Walls
of the United States, while the codes from the Southern
Building Code Congress International (SBCCI) were used in
the Southeast and the codes published by the International
Conference of Building Officials (ICBO) covered the West
Coast and across to most of the Midwest. After three years
67
fischer catalogue FireStop
BS 8414:2020 EN 13501-1:2019 EN 1366-4:2021 ASTM E 84 (UL 723) ASTM E 1966 (UL 2079) ASTM E 814 (UL 1479)
Fire performance of Fire classification of Fire resistance tests for Test method for Surface Test method for Test method for Fire
external cladding sys- construction products service installations - Burning Characteristics Fire-Resistive Joint Sys- Tests of Through Pene-
tems. Test method for and building elements. Linear joint seals. of Building materials. tems. This test is used trations Fire Stops. This
non-loadbearing exter- Reaction to Fire. The test evaluates to evaluate the perfor- test is used to evaluate
nal cladding systems EN ISO 10140:2021 the spread of flame mance of a joint af ter the performance of
EN 13501-2:2016 The laboratory meas- along the surface of a cyclic movement test a firestop system,
Fire classification of urement of airborne the material. It is no t a and fire exposure test. following fire exposure
construction products sound insulation of resistance test. UL 2079 - equivalent. a hose s tream test is
and building elements. buildng elements. conducted. UL 1479 -
Resistance to Fire. equivalent.
EN 1026: 2016
EN 1366-3:2020 Air permeability test
Fire resistance tests for method.
service installations –
Penetration seals. EN 1027: 2016
Water permeability test
EN 1364-4:2014 method.
Fire resistance tests
for non-loadbearing
elements – Curtain wall-
ing-Part Configuration.
68
fischer catalogue FireStop
– – ● ● ● – – ● – ● – – ● – – – 4
– – – – ● ● – ● – ● ● ● ● ● ● – 6
3
– – ● ● – – – ● – – – – – – – – 8
– ● – – ● – ● ● ● ● – – ● ● – – 11
– – ● ● – – – ● ● 14
– – – – ● ● ● ● – ● ● ● ● ● ● – 16
– – ● ● – ● – – – ● ● ● ● – – – 19
– – ● – ● – – – – – – – – – – – 21
– – ● ● – – – – – – ● ● – – – – 24
– – – – ● ● ● – – ● ● ● – – – – 26
– – ● ● – – – – – – ● ● – – – – 29
– – – ● – – – – – – – ● – – – – 31
– – ● ● – – – – – ● – – ● – – – 33
– – – – – – – – – – – – ● – – – 35
– – ● ● – – – – – ● ● ● ● ● – – 37
– – ● – ● – – – – ● ● ● ● ● – – 39
● – – – – – – – ● – – – – – – ● 42
● – ● – – – – ● – – – – – – – ● 45
– – ● – – – – ● – – – – – – – – 47
– – – – – – – – – – – – ● – – – 49
DIN
DIN 4102:Part1 FM Approvals is an UL-EU Mark is intended UL is an abbreviation for Underwriters NFPA 285
Fire behaviour of international leader in for use on products Laboratories Inc. which is an Sandard Fire Test Method for Evalua-
building material and el- third-party certification destined for the independant, not for profit product tion of fire propagation characterisitcs
ements - Part 1: Building and approval of European marketplace. safety testing and cer tification of exterior wall assemblies containing
materials, concepts. commercial and organisation. combustible components
industrial products.
CE
European Technical Approval/Assessment Issued by a European FBC™ System Compatible indicates
approval authority (e. g. DIBt) on the basis of the guidelines for that this product has been tested, and
European technical approvals (ETAG). ETA (English): European is monitored on an ongoing basis,
Technical Approval/Assessment. CE: The CE marks the conformity to assure its chemical compatibility
of the product to all applicable legal provisions in which their instal- with FlowGuard Gold®, BlazeMaster®
lation is intended. This means that the CE mark only certifies that and Corzan® pipe and fittings. FBC™,
the requirements determined in the relevant harmonisation legal FlowGuard Gold®, BlazeMaster® and
provisions of the union have been complied with. Products with the Corzan® are licensed trademarks of
CE mark can be freely traded in the European Economic Market. The Lubrizol Corporation.
69
fischer catalogue FireStop
Calculation of
consumption guide.
Calculation for mastic/sealant Professional App
a = Hole diameter in mm The Mobile Guide to Fixing Solutions for
b = Depth of sealant in mm/wet film thickness for spray material (see recommendations) Professionals.
3
c = Pipe or bunched cables diameter in mm The Firestop module in the app offers the
d = Annular space in mm (see r ecommendations) possibility to calculate the quantity
l = Length of square opening/joint (Calculation of consumption) automatically.
w = Width of square opening/joint
h = Cartridge or spray bucket size in ml
n = Number of holes
e = Area of hole in mm2 = π(a ÷ 2)2
f = area of pipe in mm2 = π (a ÷ 2)2
g = Amount of mastic needed per hole in ml = ((e-f) x b) ÷ 1,000
Round holes
No. of cartridges needed = n x (g ÷ h) Example: e = 3.14 x 452 = 6,361.73 mm2
Area of hole e = π x (a ÷ 2)2 mm2 a = 90 mm, b = 40 mm, c = 50 mm, h = f = 3.14 x 252 = 1,963.50 mm2
Area of pipe f = π x (c ÷ 2)2 mm2 310 ml, n = 20 g = ((6,361.73 - 1,963.50) x 40) ÷ 1,000 =
Mastic volume = g = ((e-f) x b) ÷ 1,000 ml 175.92 ml
Square holes
No. of cartridges needed = n x (g ÷ h) Example: e = 90 x 100 = 9,000 mm2
Area of hole e = l x w mm2 l = 90 mm, w = 100 mm, b = 40 mm, c = 50 f = 3.14 x 252 = 1,963.50 mm2
Area of pipe f = π x (c ÷ 2)2 mm2 ml, h = 310 ml, n = 20 g = ((9,000 - 1,963.50) x 40) ÷ 1,000
Mastic volume = g = ((e-f) x b) ÷ 1,000 ml = 281.46 ml
Linear joints
No. of cartridgesbuckets =(g ÷ h) Example for mastic/sealant: e = 20 x 30,000 = 60,000 mm2
Area of joint = e = l x w mm2 w = 20 mm, l = 30m = 30,000 mm b = 10 g = (60,000 x 10) ÷ 1,000 = 6,000 ml
Mastic volume = ((e-f) x b) ÷ 1000 ml = g mm, h = 310 ml
70
fischer catalogue FireStop
fischer Training
certification.
fischer Training
Fire protection seminars with certificate for
professionals. Show your competence.
3
Become a trusted specialist of your work!
· Do the right thing quickly and safely
· Competently assess legal issues and
resolve them
Marion Leipersberger
Product Manager
FireStop
*This certificate is valid for one year from the date of issue.
71
fischer catalogue FireStop
fischer Professional.
3
The mobile fixing expert.
www.fischer-international.com
72
fischer catalogue FireStop
Consultant: Company:
Contractor: E-Mail:
3
Contact: Phone:
Email: Supplier:
Through penetration
Assembly details: Wall Floor
Penetration details:
Insulation
Others
Joints
Joint type: Head of wall Blocks Concrete Blocks Wall to wall Perimeter joint
Special conditions/comments/drawings/standards
73
fischer catalogue FireStop
74
4
Service 4
Content
Portfolio 78
fischer subsidiaries 80
75
Service · Portfolio
The fixing catalogue offers many facts and helps with quick
and safe product selection, e.g.:
The Façade Systems catalogue offers many facts and helps with
quick and safe product selection, e.g.:
76
Service · Portfolio
Many facts about the products and everything you need to know
about fischer installation systems, e.g.:
· Presentation of the bolt and rail types and their possible combinati-
ons, with detailed technical data and illustrations
· Application support and references
· Basic knowledge on applications, processing and services
· Available design software
77
Service · fischer subsidiaries
78
Service · fischer subsidiaries
Qatar Sweden
fischer fasteners QD Trading LLC fischer Sverige AB
HUB Business Center, Barwa Commercial Nygatan 93
Avenue, Arkan Building, Block No. 4, Office 602 34 Norrköping
No. 56, Building No 115, Street 964, Zone P +46 11 31 44 50
56, P. O. Box – 35190 Doha [email protected]
[email protected] www.fischersverige.se
www.fischer.qa
Romania Turkey
fischer fixings Romania S.R.L. fischer Metal Sanayi Ve Ticaret Ltd Sti
Strada Oradiei, Nr. 1-3-5-7 Cevizli Mahallesi, Mustafa Kemal Paşa Cad.
400220 Cluj Napoca, Judetul Cluj Seyit Gazi Sok. No 66, Hukukçular Towers A
P +40 264 455 166 Blok, 34865 Kartal İstanbul
F +40 264 403 060 P +90 216 326 00 66
[email protected] F +90 216 326 00 18
www.fischer.com.ro [email protected]
www.fischer.com.tr
79
fischer catalogue FireStop
80
fischer catalogue FireStop
The information in this catalogue is intended for general guidance only and
is given without engagement. Additional information and advice on specific
applications is available from our Technical Support Team. For this however, we
require a precise description of your particular application.
All the data in this catalogue concerning work with our fixing elements must be
adapted to suit local conditions and the type of materials in use.
If no detailed performance specifications are given for certain articles and
types, please contact our Technical Service Department for advice.
We cannot be responsible for any errors, and we reserve the right to make
technical and range modifications without notice.
No liability is accepted for printing errors and omissions.
81