Instruction Sheet 734 111: Set of Machines 10 W
Instruction Sheet 734 111: Set of Machines 10 W
Instruction Sheet 734 111: Set of Machines 10 W
Set of machines 10 W
The set of machines 10 W represents an electric drive with two • The device's design lends itself to connecting to a di-
permanently excited DC machines. The coupled machines can rect voltage of ±15 V DC, preferably: 726 86 Stabilized
for example operate as a motor-generator set. The drive's power supply ±15 V / 3 A. Operation with other power
speed is captured optoelectronically and output as an analog supply units is also possible.
voltage at Vn (16). The generator voltage VG (15) can also be • The sockets IL (11), Vn (16), and VM (18) are outputs.
measured. A FET transistor mounted on the heat sink (14) Do not connect any signal or voltage sources here.
functions as a voltage-controlled load that can receive the elec- • The socket VG (15) is both an output for the generator
trical power the generator produced. Actual load curves can be
voltage and an input during active braking.
measured. The seven-segment displays represent the torque
generated with a load and the current speed, which can be • The device complies with the safety regulations in ef-
measured as analog voltages (3, 16, 18). No external power fect and bears the CE mark. Proper usage ensures
amplifier is necessary to operate the motor. The switchable the safety of those carrying out the experiments and of
prefilter (Dynamic Response = DR filter) amplifies the system the connected devices.
order. The set of machines 10 W then also behaves during • To prevent operating errors, please read this Instruc-
measurements with a greater time resolution like a 2nd order tion Sheet carefully.
system.
3 Startup
Also required:
1 power supply 726 86
1 reference variable generator 734 02
In preparation, connect the set of machines to the DC power
supply: ±15 V and ground to bus lines (1), (9) and (10).
Instruction Sheet 734 111 Page 2/2
4 Technical Data
Supply voltage: ±15 V DC Feeding a control voltage, e.g. from the reference variable
generator 734 02 or from Profi-CASSY 524 016 starts turning
Current consumption: +1.5 A max./-0.1 A the set of machines. The speed's step response to a reference
with motor blocking step depends on the DR filter's status. Following are two typical
Safety regulations: VDE 0411 examples recorded and analyzed with Profi-CASSY and
CASSY Lab 2. In the measurement examples, the input voltage
Displays: 7 segments, 4/5 digits
-1
experiences a step after t = 3 s from 2 VDC to 7 VDC (red
Speed: ±3500 min max. for ±10 V curves). The blue curves show how the speed progresses.
at socket (5)
-1
±1800 min max. for ±10 V Step response with DR filter off
at socket (15) rn
tV /Ys
Upm
10 3500
0 5 10
-3
Torque: 25 x 10 Nm max.
3000
Sockets: SIBUS, 4 mm
1000
Remarks
500
terminals.
• The generator can therefore also connect to an exter-
nal power amplifier or a power supply. This also allows
for active braking. Step response with DR filter on
nV
t pm
rU /Ys
•
10 3500
5 Operation 1000
After switching the power supply on, an LED and display test
takes place, and the device's firmware version appears in the 500
Speed: 0/min
-3
Torque: 0.0 x 10 Nm The prefilter slows the step response down and makes analysis
DR filter: ON/OFF (last setting) easier.