TSH-IP-00.0040 - 01 Total Length Inspection

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

For PVD Qualification

Prepared by: Reviewed by: Approved by:

Rubén Stubelt Michael Soptick Daniel Baiz


Premium Connections Premium Connections Premium Connections
Manufacturing Services Coordinator Manufacturing Services Specialist Manufacturing Engineering Manager
Tenaris Tenaris Tenaris

Inspection Procedure

Total Length Inspection

Document Number TSH-IP-00.0040


Revision 01
Revision Date 01-Sep-2008
Effective Date 20-Oct-2008
Page(s) 4

This document as well as the information or data contained herein are confidential and shall not be copied, recopied,
reproduced, transmitted, disclosed or distributed to others or otherwise used for any purpose without the express, prior
and written permission of Tenaris Connections AG and/or Hydril Company and/or its affiliated companies ("Tenaris").
This document as well as the information or data contained herein are the exclusive property of Tenaris, and are to be
returned upon request therefore. All rights in proprietary and novel features of the subject matter are expressly reserved
by Tenaris. Recipient’s agreement to the foregoing is indicated by acceptance of this document. Copyrighted 2008 as an
unpublished work. ALL RIGHTS RESERVED.
For PVD Qualification Document Type Inspection Procedure
Document Number TSH-IP-00.0040
Total Length Inspection Revision 01

Page Number 2

1. REVISION HISTORY

Effective
Rev. # Change Referenced Sections Prepared By: Reviewed by: Approved By:
Date

20-Oct-2008 01 New Document New Document


Name: R. Stubelt Name: M. Soptick Name: D. Baiz

Document Change

Disposition of
Affected Material

Raw Material X
In Process X
Completed X
For PVD Qualification Document Type Inspection Procedure
Document Number TSH-IP-00.0040
Total Length Inspection Revision 01

Page Number 3

2. PURPOSE

2.1 The Purpose of this document is to explain the measurement of the Total Length.

3. PERSONS AFFECTED

3.1 This document is applicable to all:


3.1.1 All Tenaris Premium Connections Manufacturing Services Personnel.
3.1.2 Facilities licensed to thread TenarisHydril connections.

4. REFERENCES

4.1 Not Applicable.

5. DEFINITIONS AND ABBREVIATIONS

5.1 Definitions and Abbreviations are defined in the most current revision of TenarisHydril document
TSH-GP-00.0001.

5.2 Total Length: The Total Length is the distance between the face of the pin or box and the last
shoulder.

6. RESPONSIBILITIES

6.1 Responsibilities are defined in the most current revision of TenarisHydril document
TSH-GP-00.0002.
7. PERSONNEL QUALIFICATION

7.1 Personnel qualification is defined in the most current revision of TenarisHydril document
TSH-GP-00.0003.
8. PROCEDURES

8.1 Inspection
Place the anvil of the depth micrometer against the face of the pin or box and extend the stem to
make contact firmly with the last Shoulder or thread scratch, please refer to the appropriate
inspection procedure for details regarding the necessary equipment.

8.2 Acceptance / Rejection Criteria


The Total Length is acceptable if the distance between the pin or box face and the last shoulder
or thread scratch, measured parallel to the pipe axis (not the thread axis), is within the limits
prescribed on the IR.

8.3 Records
The result of this inspection shall be recorded on the IR.
For PVD Qualification Document Type Inspection Procedure
Document Number TSH-IP-00.0040
Total Length Inspection Revision 01

Page Number 4

9. ANNEX

9.1 Not Applicable.