ANNEX 5.6 Checking The IHO Presentation Library Edition Number in The ECDIS

1) The document discusses checking the edition number of the IHO Presentation Library that is installed in an ECDIS system. 2) It notes that IHO Presentation Library edition 4.0 introduced new symbols and changes that address display anomalies. 3) It provides guidance on how mariners can check which edition of the Presentation Library their ECDIS uses and view the new symbols introduced in edition 4.0 using the ECDIS Chart 1 dataset.

Uploaded by

zikri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views4 pages

ANNEX 5.6 Checking The IHO Presentation Library Edition Number in The ECDIS

1) The document discusses checking the edition number of the IHO Presentation Library that is installed in an ECDIS system. 2) It notes that IHO Presentation Library edition 4.0 introduced new symbols and changes that address display anomalies. 3) It provides guidance on how mariners can check which edition of the Presentation Library their ECDIS uses and view the new symbols introduced in edition 4.0 using the ECDIS Chart 1 dataset.

Uploaded by

zikri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

ANNEX 5.

6 ‐ CHECKING THE IHO PRESENTATION LIBRARY EDITION


NUMBER IN THE ECDIS

Checking the IHO presentation Library edition number in the ECDIS

Background - IHO ENC Check dataset

In October 2011 the IHO issued the ECDIS Data Presentation and Performance Checks, which included
two fictitious ENC cells intended to assist mariners identifying if their ECDIS was using the latest IHO S-52
Presentation Library, edition 3.4. The dataset also highlighted if there were any known ENC display
anomalies present in the system. Mariners were asked to run a series of quick tests using the check
datasets within their ECDIS to ascertain if they were experiencing display issues. If the system was found
to be running an old IHO Presentation Library or had a more serious display anomaly Mariners were
advised to contact their ECDIS manufacturer or an appropriate equipment maintenance company to
obtain software patches and investigate further to resolve the issues. Results of the tests were to be
sent to the IHO for analysis and for use in revising IHO standards.

The IHO ECDIS Data Presentation and Performance Checklist were not intended for, and are not suitable
to be used as a Port State Inspection / Carriage compliance test for ECDIS.

To address the display anomalies and improve the ECDIS user experience the IHO issued S-52
Presentation Library edition 4.0 in September 2014.

One of the principal benefits of upgrading ECDIS systems to the latest IHO Presentation Library is the
reduction in audible alarms, which will ease the issue of alarm fatigue on the bridge whilst maintaining
safety at sea. The introduction of an alert model based on the requirements in the IMO ECDIS
Performance Standard will also harmonize ECDIS alarm and indication behaviour across different
manufacturers systems.

A number of new symbols have also been added to the IHO Presentation Library. These symbols will
identify features that require an indication highlight; the location of automatic ENC updates; and ENC
features that have a temporal attribute.

A number of other significant changes in the Presentation Library have come directly from feedback
provided by mariners. For example, the names of Fairways and Anchorage Areas will now appear on the
ENC display; and a hover over function for certain charted features has been introduced. The IHO has
co-ordinated with the IEC to align the issue dates of S-52 and IEC 61174 "ECDIS Operational and
performance requirements, methods of testing and required test results" publications.

This resulted in a new edition (4.0} of IEC 61174 being published in August 2015 for the type- approval of
new ECDIS. By 1st September 2017, ECDIS which have been type-approved according to a previous
edition of IEC 61174 should have been updated in order to comply with the ECDIS software updating
guidance in MSC.1.Circ.1503 as amended.

Changes to the IHO S-52 Presentation Library introduced in edition 4.0 invalidate the tests contained in
IHO ECDIS Data Presentation and Performance Checks which were specifically designed and developed
for ECDIS using the IHO S-52 Presentation Library edition 3.4 or earlier.

Hydrographic information driving marine knowledge

ECDIS and the IHO Presentation Library Edition Number

All ECDIS must have a function to display the edition number of the IHO Presentation Library that is in
use within the ECDIS. The new IHO ECDIS Presentation library edition 4.0 clause 19.1 states; 'The edition
number of the Preslib installed must be available to the Mariner on request'. This requirement is tested
for in the standard IEC 61174 edition 4 clause 5.5.1, Presentation library {S- 52/Annex A, Part I/19.1)
'The edition number of the Preslib installed shall be available to the Mariner on request'.

All Mariners must familiarise themselves with the function in their ECDIS that will display the edition
number of the IHO Presentation Library as this varies across ECDIS manufactures. This function will be
required when Port State Control officers want evidence that the ECDIS is up-to-date to the latest IHO
standards. MSC.1.Circ.1503 as amended: 'Additionally, ECDIS software should be kept up to date such
that it is capable of displaying up-to-date electronic charts correctly according to the latest version of
IHO's chart content and display standards'.

A list of current IHO Standards in force is maintained on the IHO website.


http://www.iho.int/mtg_docs/enc/ECDIS-ENC_StdsIn_Force.htm

ECDIS Chart 1 and IHO Presentation Library edition 4.0

ECDIS users can check that their systems are capable of displaying the new symbols introduced in the
IHO S-52 Presentation Library edition 4.0 by opening the ECDIS Chart 1 datasets. ECDIS Chart 1, which
includes a legend of symbols used in ENC's, should be installed on all type approved ECDIS. The new
symbols introduced in IHO Presentation Library edition 4.0 are shown below

Magenta 'd' symbol for features that


have date dependent attributes
populated.

Indication highlight symbology for


objects that pose a danger to the
vessel.

Automatic update symbology for


identifying where changes to the
ENCs have occurred.

Fig 1. New ENC Symbols introduced in /HO S-52 Presentation library edition 4.0

ECDIS Chart 1

Viewing ECDIS Chart 1, "Information about chart display {A, B)" within the ECDIS will only display the
new symbols if the IHO Presentation Library edition 4.0 is installed. The beacon and buoy features below
(approx. position is 15°07.0'N 005°06.5'W) display the date dependent magenta 'd' symbol when the
ECDIS date range is set between 01.04.2014 and 27.08.2014. It will not be possible to view the new
symbols if the ECDIS software has not been updated to use the S-52 Presentation Library Edition 4.0.
This is the IHO recommended method for checking that the ECDIS system can display the new symbols
correctly. There is no intention for the IHO to issue a check data set for IHO Presentation Library edition