Bestway MKR5000D Series OwManual (EN)
Bestway MKR5000D Series OwManual (EN)
Bestway MKR5000D Series OwManual (EN)
Options
Features & Benefits ∗ 14' Electrical Harness Extension
∗ High Quality - Low Cost ∗ Quick Detach Mounting Kit
∗ High Foam Output ∗ RibbonFoamTM Fittings Kit
∗ Reliable FoamTubeTM Design
∗ Adjustable Foam Density Specifications
∗ Low Current Requirement Tank Size ............................................. 14 Gallons
∗ Fully Assembled - Easy Installation Average Foam Output ........... 5.2 Gallons / Minute
∗ Non Pressurized Tank Average Solution Usage........... 6.8 Gallons / Hour
∗ Heavy Duty Foam Boots Average Drop Interval ....................... 4.9 Seconds
Average Drop Distance (10 MPH).....................72'
FoamTubeTM Design ....................................... Yes
Is The MKR-5000D For You? Sealed Electrical Connections......................... Yes
This model is for difficult marking conditions Breaker Protection........................................... Yes
at slower speeds or normal marking conditions at Foam Boot Size................................................. 6"
high speeds (over 10 MPH). Performance in no-till, Adjustable Foam Density Control.................... Yes
maximum residue fields and standing crops will be Dimensions............................. 12"W x 22"L x 24"H
excellent unless conditions are extreme. Mounting Footprint .................................. 12" x 22"
RibbonFoamTM is possible with the MKR-5000D, Weight ........................................................48 Lbs.
but results may or may not be adequate based on
the particular field condition. The MKR-5000D is a
good combination of high performance and System Requirements
economy. Voltage Requirement................... 12 - 14 Volts DC
Amperage Requirement ............. 25 Amperes Max
Installation
Step 1:
Find a suitable place to locate the main unit. If this is a unit with a tank, keep in mind it will weigh
approximately 150 lbs. when full. Pick a position that will have a reasonably good ride, preferrably on
the sprayer unit itself. Mounting on the boom itself is OK if the ride is not expected to have much jolting
movement.
Step 2:
Attach the main unit to a flat surface using four bolts and large flat washers over the slotted holes. Face
the front cover of the black cabinet toward an open area so that maintenance and service can be easily
performed. The pressure gauge on top of the cabinet should be situated for easy viewing while
adjusting the knob, also located on top of the cabinet. If this is unit does not include the tank, a steel
framework is provided on the back of the black cabinet for mounting purposes. It's important to mount
the cabinet vertically so the pressure gauge is on the top side.
Step 3:
On the end of each boom, mount the two foam drops. You can use either the 3" hose clamps provided,
or improvise your own mounting design. The operation of the foam marker is optimized when used with
these foam drops. The hose used on the drop is very flexible and tough in case the boom drags close to
the ground.
Step 4:
After the boom drops are in place, connect the 3/4" hose to the drops. Run each length of hose to the
Directo-Valve on the bottom of the cabinet. Attach the left side to Outlet #2, and the right side to Outlet
#1. Secure the hose to the boom using the tie straps provided. If you are installing a one-side
discharge model, no Directo-Valve will be installed. In this case attach the hose to the hose barb
protruding from under the cabinet.
Directo-Valve Assignments
Right Side <---> Outlet #1
Left Side <---> Outlet #2
Step 5:
Install the Cab Control in a convenient place close to the operator seat. You may use either the Velcro
patches provided or replace the box screws with longer ones for a bolted mount. Connect the power
leads to a good source of 12 volt power. If you are not attaching the power leads directly to the battery,
make certain the wires feeding your hookup location are at least 12 gauge. It is not necessary to
provide a circuit breaker, since the breaker is provided on the MKR control.
Step 6:
Extend the 28', four-wire extension cable back to the foam unit. If you need additional cable, call your
dealer for more. DO NOT ATTEMPT TO MAKE YOUR OWN EXTENSION! Plug in the large black
Packard connector and the unit is ready to operate.
Solution Preparation
Selecting A Concentrate
Always use high quality foam concentrate. We recommend Bestway DuraFoam 160TM for all general
purpose marking. Be aware that a lot of poor quality foam concentrate is sold every year to
unsuspecting customers. Some concentrates may work well in some circumstances and not others, so
be careful.
When the knob is turned fully counter-clockwise, the liquid pump is shut completely off. By rotating the
knob clockwise, the pump will speed up and the pressure will rise. Speed the pump to 100% to aid in
priming on the first tank fill.
Normally, you should operate the pressure between 20 to 40 PSI. Operating under 20 PSI will often
result in intermittent foam because there simply isn't enough liquid pressure to overcome the foam
discharge pressure. Operating over 40 PSI will use excessive solution and will create a very wet foam.
(You might like this in very hot, dry conditions). Never operate the unit continuously over 60 PSI.
Try to keep dirt and debris out of the tank at all times. The marker is protected by a large 80 Mesh
strainer under the tank and by a 100 Mesh strainer in the line ahead of the liquid orifice. These may
need cleaning periodically, depending on operator cleanliness.