Branch Reinforcement Calc

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Branched Connection Reinforcement Calculation Agility Team Build

(refer B31.3 Section 304.3)


SITE : Wiluna Compressor Station Liquids Dump Tank DATE: 12-Mar-24
Run or Header Pipe Details
Diameter, Dh 610 mm
Wall Thickness, Th 9.53 mm (less mill allowance)
c 0.0 mm (thread and corrosion allowance)
Design Thickness, th 5.066 mm (Calculated from B31.3 wt calculation)

Branch Pipe Details


Diameter, Db 219.1 mm
Wall Thickness, Tb 8.18 mm (less mill allowance)
c 0.0 mm (thread and corrosion allowance)
Design Thickness, tb 1.8 mm (Calculated from B31.3 wt calculation)
d1 202.7 mm
d2 202.7 mm (Since Tb + Th +d1/2 is < d1)
L4 20.5 mm (Use the lesser of Tb and Th)

A1 1027.08 mm2 (assume Branch and Header are perpendicular and have intersecting axes)
A2 905.031 mm2
A3 260.124 mm2 (assume Branch and Header are perpendicular and have intersecting axes)

BRANCH OK
Branched Connection Reinforcement Calculation Agility Team Build
(refer AS 2885.1 Section 4.3.9.5 and AS4041 Section 3.19.7 and 8)
SITE : DATE: 12-Mar-24
Pipe Details
API 5LX Yeild Stress
Carrier/main pipe diameter, D 273.1 mm ratio d/D 17.7% Gr A 207
Carrier/main pipe wall, th 12.7 mm ratio sc/sy 45.5% Gr B 241
Carrier/main pipe inside diam 247.7 mm X42 289
Branch pipe diameter, d 48.3 mm X46 317
Branch pipe wall, tb 5.08 mm X60 413
Branch pipe inside diam 38.14 mm
Operating Pressure 10.2 MPa
Yield Stress of main pipe, sy 241 MPa
Hoop Stress of main pipe, sc 109.7 MPa

AS 2885.1 Section 4.3.9.5 Refer Table 4.3.9.5

REINFORCEMENT NOT MANDATORY FOR BRANCH DIAMETER <= 60.3


REINFORCEMNET SHALL BE PROVIDED AS REQUIRED BY AS 4041

AS 4041 Section 3.19.7

Check the nominal wt of the branch fitting is not < that determnined in accordance with Section 3.14.2
OK, NO FURTHER REINFORCEMENT REQUIRED
ADDITIONAL REINFORCEMENT REQUIRED
FOR SPECIAL REQUIREMENTS REFER TO 3.19.7
REINFORCEMENT REQUIREMENTS MUST COMPLY WITH 3.19.8

AS 4041 Section 3.19.8


Design Strengths (Mpa)
Additional thickness in branch using method in Appendix L. Temp 50 C 100 C
Assuming branch is not affected by other branches. API 5LX
x factor 0.80 Fiquire L3 d2/d1 0.1540 Grd B 160 147
If d2/d1 does not exceed 0.3 use 1.0 for x f/p 14.41 X42 176
Minimum thickness of branch, tm2 1.736 mm X46
BRANCH OK X52 194
X60
Additional thickness in main using Appendix L. X70
Assuming main is not affected by other branches. X80

Minimum thickness of branch, tm1 11.23 mm ASTM


BRANCH OK A694 Gr F60
A234 Gr WPB 160

A106 160
A105 160

Additional thickness in branch using method in Section 3.19.8

Required reinforcement area, At 349.26 mm2

A1 111.98 mm2 Provided by excess wall in main


A2 195.32 mm2 Provided by excess wall in branch
A3 50.00 mm2 Provided by weld metal joining main pipe and branch
A4 0.00 mm2 Provided by reinforcing ring
A5 0.00 mm2 Provided by saddle on a right-angle connection

NO ADDITIONAL REINFORCING REQUIRED