Branch Reinforcement Calc
Branch Reinforcement Calc
Branch Reinforcement Calc
A1 1027.08 mm2 (assume Branch and Header are perpendicular and have intersecting axes)
A2 905.031 mm2
A3 260.124 mm2 (assume Branch and Header are perpendicular and have intersecting axes)
BRANCH OK
Branched Connection Reinforcement Calculation Agility Team Build
(refer AS 2885.1 Section 4.3.9.5 and AS4041 Section 3.19.7 and 8)
SITE : DATE: 12-Mar-24
Pipe Details
API 5LX Yeild Stress
Carrier/main pipe diameter, D 273.1 mm ratio d/D 17.7% Gr A 207
Carrier/main pipe wall, th 12.7 mm ratio sc/sy 45.5% Gr B 241
Carrier/main pipe inside diam 247.7 mm X42 289
Branch pipe diameter, d 48.3 mm X46 317
Branch pipe wall, tb 5.08 mm X60 413
Branch pipe inside diam 38.14 mm
Operating Pressure 10.2 MPa
Yield Stress of main pipe, sy 241 MPa
Hoop Stress of main pipe, sc 109.7 MPa
Check the nominal wt of the branch fitting is not < that determnined in accordance with Section 3.14.2
OK, NO FURTHER REINFORCEMENT REQUIRED
ADDITIONAL REINFORCEMENT REQUIRED
FOR SPECIAL REQUIREMENTS REFER TO 3.19.7
REINFORCEMENT REQUIREMENTS MUST COMPLY WITH 3.19.8
A106 160
A105 160