Service Manual: TC-21PM30R
Service Manual: TC-21PM30R
Service Manual: TC-21PM30R
MTV 0010147C3
TC-21PM30R
MX-7 Chassis
Specifications
Power Source : AC AUTO 110-240V, 50/60Hz Video / Audio Terminals :
FAV In : Video In 1 Vp-p 75Ω
Power Consumption : 86W Audio In Approx, 400mVrms
RAV In : Video In 1 Vp-p 75Ω
Aerial Impedance:75 Ωunbalanced Audio In Approx, 400mVrms
Coaxial type Monitor Out :Video Out1 Vp-p 75Ω
Audio OutApprox, 400mVrms
Receiving System : 17 System
Receiving Channels : High Voltage : 28.0 kV ( +/- 1.0 )
VHF 2-12 (PAL/SECAM B,K1) at zero beam current
0-12 (PAL B AUST)
1-9 (PAL B N.Z) Picture Tube : XA51LSK955X-A
1-12 (PAL/SECAM D) 51cm (21 inches)
1-12 (NTSC M JAPAN) Measured diagonally, 90 °deflection
2-13 (NTSC M U.S.A)
UHF 21-69 (PAL G,H,I/SECAM G,K,K1)
28-69 (PAL B AUST) Audio Output : 3.5W x 2 = 7W
13-57 (PAL D,K)
13-62 (NTSC M JAPAN)
14-69 (NTSC M U.S.A)
CATV S1-S41(OSCAR) Dimensions : Height : 473.6 mm
1-125 (U.S.A CATV) Width : 600 mm
C13-C41(JAPAN) Depth : 484.4 mm
S21-S41 (HYPER)
Z1-Z37 (CHINA) Mass : 23.4 kg
Intermediate Frequency :
Video 38.0 MHz Specifications are subject to change without
Sound 31.5 MHz (D,K) / 32.5MHz (B,G) notice.Mass and dimensions shown are approxi
32.0 MHz (I) / 32.5MHz (M) mate.
Colour 33.57 MHz (PAL)
33.6 MHz (SECAM)
c 2000 Matsushita Electric Industrial Co., Ltd.
32.5 MHz (B,G) All right reserved.Unauthorized copying and
33.75 MHz (SECAM) distribution is a violation of law.
34.42 MHz (NTSC)
Panasonic
Contents
.Adjustments ...................................................................................................7
1. It is advisable to insert an isolation transformer in the AC supply before servicing this hot chassis.
2. When servicing, observe the original lead dress, especially the lead dress in the high voltage circuits. If
a short circuits is found, replace all parts which have been overheated or damaged by the short circuit.
3. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers,
shields, and isolation R-C combinations, are properly installed.
4. When the receiver is not to be used for a long period of time, unplug the power cord from the AC cord
outlet.
5. Potential, as high as 28.0kV. is present when this receiver is in operation. Operation of the receiver
without the rear cover involves the danger of a shock hazard from the receiver power supply. Servicing
should not be attempted by anyone who is not thoroughly familiar with the precautions necessary when
working on high voltage equipment. Always discharge the anode of the picture tube to the receiver
chassis before handling the tube.
After servicing make the following leakage current checks to prevent the customer from being exposed
to shock hazards.
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Turn on the receiver’s power switch.
Measure the resistance value, with an ohmmeter, between the jumper AC plug and each exposed metal-
lic cabinet part on the receiver, such as screw heads, aerials, connectors, control shafts, ect. When the
exposed metallic part has a return path to the chassis, the reading should be between 4 Mohm and 20
Mohm.When the exposed metal does not have a return path to the chassis, the reading must be infinite.
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Check a 2 kohm non-inductive resistor and an AC/DC current meter, in series with each exposed
metallic part on the receiver in turn and an earth such as a water pipe.
The current from any point should not exceed 0.7 mA peak AC or 2mA DC. In the case of a measure-
ment being outside of these limits specified, there is a possibility of a shock hazard, and the receiver
should be repaired and rechecked before it is returned to the customer.
Fig.1
Warning :
The potential sources of X-Radiation in TV set
are the EHT section and the picture tube.
When using a picture tube test jig for service,
ensure that jig is capable of handling 28.1kV
without causing X-Radiation.
Note : It is important to use an accurate
periodically calibrated high voltage
meter.
1. Set the brightness to minimum.
2. Use the remocon to get into Service Mode.
3. Measure the EHT. The meter reading should
indicate 28.0(+-1.0)kV. If the meter
indication is out of tolerance, immediate
service and correction is required to prevent
the possibility of premature component failure.
4. To prevent the possibility X-Radiation, it is
essential to use the specifield picture tube, if
service replacement becomes necessary.
Fig.7
How To Set : To set the Factory mode, press Volume 0 dac on the TV and Timer Setting 30min
on the remote control and press Volume (-) Down button on the TV together press
recall on the remote control.
CHK should appear on right of TV screen.
To move from CHK1 to CHK2 mode, etc, please follow below rotation :
To Set Self-Check : Press the volume down button on TV than press the off timer button on
remote control.
Preparation :
1. Receive the white balance pattern and aging should have been performed over 30 minutes.
2. Set the picture menu to to DYNAMIC NORMAL.
3. Degause the CRT face.
4. Fix the CRT colour analyzer receiver unit to CRT face.
Preparation :
1. Connect ocilloscope probe to TPL7.
2. Screen VR min.
3. Set the data Sub Bright , Bright.
4. In service Mode at ‘Bright’ dac press [5] in factory mode to enter vertical line and adjust by
volume down or up button.
5. Adjust “Screen VR” until 1-H Line appears.
130V
0V
+B Voltage
1. Operate the TV set. Confirm the DC voltage at the indicated test points,
as follow :
2. Set control as follow : TPA 12 : 141.2 +- 0.8V TPA 21 : 215 +- 15V
Brightness ..... minimum TPA 11 : 8 +- 1V
Contrast ........ minimum TPA 10 : 5 +- 1V
RF AGC
1. Receive a colour bar signal at an 1. Select “RF AGC” indication in CHK 2, on Screen
RF level of 64(+0-1)dBU with 75Ω by remote control at factory mode.
loaded.
2. Connect digital multimeter to RF AGC 2. Set RF AGC by using remote control volume (+)
at Tuner. or volume (-) button until voltage AGC at Tuner
reach 2.7 +- 0.1V.
3. Increase RF signal strenght by 2dB, confirm
AGC at Tuner voltage drop.
High Voltage
0.5a
7 8 9 10
1 2 3 4 5 6
Fig. 10
1. Receive the PAL B/G studio colour bar pattern, and adjust local frequency at the best tuned
position.
2. Pic Menu : Dynamic Normal , Confirm Contrast - 63 , Sub Contrast - 21.
3. Channel colour set ----------- STD.
4. Connect TPA 10 to TPA 20.
5. Set (A) to 2.3 +- 0.2V by BRT (CHK2) Fig. 1.
Adjustment
1. Connect oscilloscope probe to TPA 31 (G OUT) with 10k series resistor and adjust Contrast so
that (B) as in Fig.1 is 2.8 +- 0.1V.
2. Adjust ‘Sub Colour’ so that waveform as in Fig.1 (1) 2.55 +- 0.1V.
3. Connect oscilloscope probe to TPA 32 (R OUT) with 10k series resistor and confirm waveform as in
Fig.2 is (2).2.7 +- 0.4V
2
B
1
A A
0V
Fig. 1 Fig. 2
1. Set the Brightness and Contrast controls to 1. Apply a crosshatch pattern signal and
their maximum postions. Normalize Contrast control to the
2. Operate the TV set for 30 minutes. maximum positions.
3. Fully degauss the picture tube by using an 2. Adjust Brightness until the grey position of
external degaussing coil. the crosshacth pattern just becomes black.
4. Apply a crosshatch pattern signal and adjust 3. Adjust the Red and Blue line at the centre of
the static convergence magnets to the the screen by rotating the R-B static
approximately correct position.
5. Receive a black and White signal. Slide magnetic tabs toward or away from
6. Set the control as following: Vertical each other.
Convergence
Red ................ minimum
Green ............. minimum Red & Blue
Blue ............... minimum
R-B Static
Press the Shipping button on the remote control Convergence Magnet
twice to select CRT Adjustment Mode as per
Fig. 16 to select low light. Rotate both magnetic rings together.
Fig.22
4. Adjust Red and Blue with Green line at
Colour Purity
centre of the screen by rotating (RB) -G
static convergence magnetic rings.
5. Lock convergence magnetic with silicne
Green sealer.
6. Remove the DY wedges and slightly tilt the
Purity Magnet Green Field deflection yoke vertically and horizontally to
obtain the good overall convergence.
Fig.20
Vertical BGR
9. Slowly push the deflection yoke and set it where R R
a uniform green field is obtained. G G
B B
RGB
Horizontal
BGR
Uniform
green
Fig. 21
1. Preparation
a. Set DY to CRT not to tilt up and down left and right deflection.
b. Set CY to CRT and set CY magnet primarily (Fig.1)
Purity magnet : Set purity magnet that 2 magnet are (TOP POSITION)
VRS magnet : Set VRS magnet 2 magnet are (HORIZONTAL POSITION)
2. Adjustment
Clamp for
Convergence &
Purity Magnet
Purity Magnet
(RB)-G Static
Deflection Yoke Convergence Magnet
Fig. 24
Fig. 25
Note :
1. Wedge A,B and C should be inserted following the sequence of 1,2 and 3 shown
in Fig. 25.
3. Be certain that four wedges are firmly fixed and the Deflection Yoke is tightly clamped
in place.
Otherwise the Deflection Yoke may shift its position and cause a loss of convergence
and purity.
1. Resistor 2. Capacitor
Example : Example :
L : +/- 15%
M : +/- 20%
P : +100%, -0%
Z : +80%,-20%