REFUstore 50K... 100K Datasheet EN V06 Screen

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

REFUstore 50K ...

100K
The next generation of bidirectional
high power battery inverters

NEW
DC-PRECHARGE
OPTION

■ Drastic reduction in BOS costs


■ Maximum power density
■ Easy serviceability
■ Suitable for 2nd Life Battery Application

The REFUstore battery inverter is based on the new inverter


platform from REFU. This inverter is specifically designed
for all high voltage batteries. With a rated power of 88 kW
at 400V, it is perfectly suited for commercial behind-the-
meter applications such as self-consumption optimization
or peak-shaving.

Future Proof: The AC-coupled REFUstore can be easily


integrated with existing PV systems. The highly modular
solution allows it to be used in systems from 50 kW up to
MWs in size to meet the demands of both energy and power
applications.

Maximum Performance: The REFUstore is highly efficient


over a wide range of operation maximizing return on invest-
ment. With fast response times, the inverter achieves high
control performance, making it suitable for time-critical
applications.

Design Flexibility: The REFUstore allows different com-


munication protocols like Modbus RTU/TCP and Sunspec/
MESA. The higher flexibility in system design reduces BOS
costs drastically.

2nd Life Application: With a min. DC voltage of 280V, the


REFUstore 50K can be used in 2nd life battery applica-
tions with ease to support the grid for applications such as
frequency regulation, optimizing self-consumption, peak
MADE IN
shaving etc.
GERMANY
TECHNICAL DATA – POWERUNIT

REFUstore 88K/100K REFUstore 50K


Art. No. 420P088.020 420P050.020
Art. No. (DC-precharge integrated) 421P100.010 421P050.010
Operation Mode 100 kVA @ 88 kVA @ 83 kVA @ 50kVA @ 50kVA @ 2nd life
480 VAC 400 VAC 380 VAC 400 VAC 380 VAC application

DC DATA
Max. voltage DC (V) 1,000
Nominal voltage DC (V) 750 620 600 620 600 Usdc + 50
DC voltage range at nominal power (V) 700 ... 900 585 … 900 555 … 900 585 ... 900 555 … 900 1.46 × Uac
DC start-up open circuit voltage, Usdc (V) 700 585 555 585 555 1.46 × Uac
Max. operational current DC (A) 153 153 153 153 87 153
DC connection PowerUnit - ConnectionBox 1 Plus, 1 Minus: Connector with Button Activated Coupling

AC DATA
Apparent power (kVA) 100.0 88.0 83.3 50.0 50.0 0.222 × Uac
Rated voltage AC 3-Phase, Uac (V) 480 400 380 400 380 180 … 480
Voltage range AC (V) 180 ... 528
AC grid connection / Grid types 3 Phases, PE / TT, TN-C, TN-S
Nominal power factor / Range 1 / 0.3i … 0.3c
Rated frequency / Frequency Range (Hz) 50, 60 / 45 … 65
Max. AC current, Imax (A) 128
Max. AC short circuit current (A rms) 64 (3 period average)
Inrush current (peak / duration) 25 A / 0.5 ms
Max. THD (%) <3
Max. efficiency (%) 98.4 98.4 98.3 98.4 98.4 96.8
Maximum admissible external AC fuse 160 A, gG, Un = 500 V
Maximum admissible external DC fuse 200 A, gR, Un = 1000 V
Peak current (Ip) / Initial short circuit
128 / 325
current (Ik“) acc. IEC 60690-0 (A)
AC connection PowerUnit - ConnectionBox Connector with Button Activated Coupling

AMBIENT CONDITIONS
Cooling Smart active cooling
Max. temp. for nominal power (°C) 45
Ambient temperature (°C) - 25 ... + 60
Rel. Air humidity (%) 0 … 100
Max. elevation (m above sea level) 3,000
Noise level (dBA) < 70
Environment classification (IEC 60721-3-4) 4K4H
Type of protection IP65
Installation type Indoor / outdoor, Vertical / flat / pole mounting

SAFETY AND PROTECTION FUNCTIONS


Safety and protection devices Refer to ConnectionBox
Grid monitoring (acc. DIN V VDE V 0126-1-1) Voltage, Frequency, Passive and Active Anti-Islanding, DC injection
Grid separation Gate Block / redundant Grid Relays
Residual current monitoring (RCD) Type 2
Compatibility external RCD Type A / Type B
Protection class (IEC 62109) 1
Overvoltage category (IEC 60664-1) DC: II / AC: III
420Pxxx.020: no (required externaly)
DC-precharge
421Pxxx.010: (integrated)
TECHNICAL DATA – POWERUNIT

REFUstore 88K/100K REFUstore 50K


Art. No. 420P088.020 420P050.020
Art. No. (DC-precharge integrated) 421P100.010 421P050.010
Operation Mode 100 kVA @ 88 kVA @ 83 kVA @ 50kVA @ 50kVA @ 2nd life
480 VAC 400 VAC 380 VAC 400 VAC 380 VAC application

GENERAL DATA
Topology Transformerless
DC pole grounding not allowed
Status display / Keys 4 LED's (DC status, AC status, Fault, Bluetooth®) / 2 Keys (Connect, Clear)
Interfaces 2 × Ethernet Daisy-Chain / 2 × RS485, Bluetooth® BLE, 1 × Remote Off Signal
Communication Protocols Sunspec (Modbus TCP, Modbus RTU), USS (Ethernet, RS485)
Dimensions W × H × D (mm) 673 × 626 × 321
100
Weight (kg) 69
99

98

97
CERTIFICATES
EU Directive 96 2014/30/EU, 2014/35/EU
Efficiency (%)

IEC 62109-1, IEC 62109-2, IEC 62116, IEC 61727, IEC 62477-1,
Product
95IEC 61439, ETSI EN 300 328 V.2.1.1
EMC IEC 61000-6-2, IEC 61000-6-4
94
IEC 60068-2-1, -2-2, -2-30, -2-78, -2-14, -2-6, -2-27, -3-2, -2-75, IEC 60529,
Environment
IEC 60034-9
93
DIN VDE V 0126-1-1, VDE AR-N 4105:2011-08, BDEW Prototype Declaration,
620 VDC Discharge 620 VDC Charge
Grid Codes TOR D4, Önorm E 8001-4-712, UTE C15-712-1, EN 50438, VDE AR-N 4105:2018,
92
VDE AR-N 4110:2018, EN 50438 (BG, CY, HU, PL, RO, TR)
880 VDC Discharge 880 VDC Charge
All certificates are available at www.refu.com 91

90
0 20 40 60 80 100

Power (%/Pn)

EFFICIENCY POWER / TEMPERATURE


100 100

99 90

98 80

97 70

96
Efficiency (%)

60
Power (kVA)

95 50

94 40

93 30
620 VDC Discharge 620 VDC Charge
92 20
880 VDC Discharge 880 VDC Charge 620 VDC 750 VDC 880 VDC
91 10

90 0
0 20 40 60 80 100 35 40 45 50 55 60

Power (%/Pn) Ambient Temperature (°C)


TECHNICAL DATA – CONNECTIONBOX

CBBS (1000V-BR)
Art. No. 940P300.0000

GENERAL DATA
DC Switch no
DC Connection (+ / - ) Ring terminal block (50 ... 240 mm²)
AC Connection L1, L2, L3: M10 / PE: M8 Ring terminal block (50 … 150 mm²)
Type of protection (IEC 60529) IP54
Dimensions ConnectionBox W × H × D (mm) 760 × 692 × 166
Weight (kg) 25

POWERUNIT

CONNECTIONBOX
SINGLE LINE DIAGRAMS

System Diagram REFUstore 100K-PC (421P100.000)


(including integrated DC precharge)
OVERALL SYSTEM

Monitoring Portal

Energy Management
System (EMS)
External precharge

Energy Meter
precharge circuit
DC Switch / MCB

circuit (optional)

(only 421Pxxx)
Integrated DC

AC grid relais
Master
DC Fuse

BMS

DC +
L1

Grid Connection
L2
DC - L3

3
PEN

AC SPD (opt.)
DC SPD (opt.)

Battery Cabinet (ESS) REFUstore 50K...100K Battery Inverter (ESS PCS)

REFUstore 100K-PC (421P100.000)


POWERUNIT
(including DC precharge)
DC precharge circuit
Isolation monitoring

AC grid connection
current detection
AC mains chokes
DC Connection

(only 421Pxxx)

AC grid relais
DC EMC filter

AC EMC filter
AC residual
Inverter

DC + L1
RCD L2
DC - L3
3 PEN

ISO

Control Panel
SR Control Card

Digital RS485/ RS485/


Input LAN 1 LAN 2

REFU Elektronik GmbH2019-07-19


INSTALLATION

INSTALLATION MADE EASY


The ConnectionBox and PowerUnit can be delivered individually in separate shipments. The ConnectionBox
can be installed during cable work and the PowerUnit just before commissioning, thereby optimizing investment
and project cash flow.

This two-piece design also offers easiest serviceability – the PowerUnit can be quickly detached from the
ConnectionBox for trouble shooting and measurements – without disconnecting the power cables on the DC or
AC sides.

1 2

Install and wire Hang in PowerUnit


the ConnectionBox. before commissioning.

3
20200303_REFUstore_50K...100K_Datasheet_EN_V06

Ready.

No responsibility is taken for the correctness of this information. Subject to modification.


REFU Elektronik GmbH | Marktstraße 185 | 72793 Pfullingen | Germany | Tel. +49 7121 4332-0 | Fax +49 7121 4332-140 | [email protected] | www.refu.com

You might also like