0% found this document useful (0 votes)
383 views

Dokumen - Pub Machine Learning in Python For Dynamic Process Systems

This document provides information about a book titled "Machine Learning in Python for Dynamic Process Systems". The book is a practitioner's guide for building process modeling, predictive, and monitoring solutions using dynamic data. It is the first edition written by Ankur Kumar and Jesus Flores-Cerrillo. The book is dedicated to their families and all data science enthusiasts. It provides an overview of dynamic process modeling and system identification using machine learning techniques. The book aims to teach working process engineers and new process data scientists about dynamic process modeling in a practical and implementation-focused manner.

Uploaded by

omar4airobotics
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
383 views

Dokumen - Pub Machine Learning in Python For Dynamic Process Systems

This document provides information about a book titled "Machine Learning in Python for Dynamic Process Systems". The book is a practitioner's guide for building process modeling, predictive, and monitoring solutions using dynamic data. It is the first edition written by Ankur Kumar and Jesus Flores-Cerrillo. The book is dedicated to their families and all data science enthusiasts. It provides an overview of dynamic process modeling and system identification using machine learning techniques. The book aims to teach working process engineers and new process data scientists about dynamic process modeling in a practical and implementation-focused manner.

Uploaded by

omar4airobotics
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 208

ML for Process Industry Series

Machine Learning in Python


for Dynamic Process Systems
A practitioner’s guide for building process modeling,
predictive, and monitoring solutions using dynamic data

First Edition

Ankur Kumar, Jesus Flores-Cerrillo


`

Machine Learning in Python


for Dynamic Process
Systems

A practitioner’s guide for building process modeling,


predictive, and monitoring solutions using dynamic
data

Ankur Kumar
Jesus Flores-Cerrillo
`

Dedicated to our spouses, family, friends, motherland, and all the data-science enthusiasts
`

न चोर हार्यं न च राज हार्यं न भात्रू भाज्यं न च भारकारर

व्यर्यं कृते वर्धत एव ननत्यं नवद्यार्नं सवधर्नप्रर्ानम

No one can steal it, no king can snatch it,


It cannot be divided among the brothers and it’s not heavy to carry,
As you consume or spend, it increases; as you share, it expands,
The wealth of knowledge is the most precious wealth you can have.

- A popular Sanskrit shloka


`

Machine Learning in Python for Dynamic Process Systems

www.MLforPSE.com

Copyright © 2023 Ankur Kumar

All rights reserved. No part of this book may be reproduced or transmitted in any form or in
any manner without the prior written permission of the authors.
.

Every effort has been made in the preparation of this book to ensure the accuracy
of the information presented and obtain permissions for usage of copyrighted materials.
However, the authors make no warranties, expressed or implied, regarding errors or
omissions and assume no legal liability or responsibility for loss or damage resulting from
the use of information contained in this book.

Plant image on cover page obtained from https://pixabay.com/.


.

To request permissions, contact the authors at [email protected]

First published: June 2023


`

About the Authors

Ankur Kumar holds a PhD degree (2016) in Process Systems Engineering


from the University of Texas at Austin and a bachelor’s degree (2012) in
Chemical Engineering from the Indian Institute of Technology Bombay. He
currently works at Linde in the Advanced Digital Technologies & Systems
Group in Linde’s Center of Excellence, where he has developed several in-
house machine learning-based monitoring and process control solutions for
Linde’s hydrogen and air-separation plants. Ankur’s tools have won several
awards both within and outside Linde. Most recently, one of his tools,
PlantWatch (a plantwide fault detection and diagnosis tool), received the 2021 Industry 4.0
Award by the Confederation of Industry of the Czech Republic. Ankur has authored or co-
authored more than 10 peer-reviewed journal papers (in the areas of data-driven process
modeling and optimization), is a frequent reviewer for many top-ranked research journals,
and has served as Session Chair at several international conferences. Ankur also served as
an Associate Editor of the Journal of Process Control from 2019 to 2021.

Jesus Flores-Cerrillo is currently an Associate Director - R&D at Linde and


manages the Advanced Digital Technologies & Systems Group in Linde’s
Center of Excellence. He has over 20 years of experience in the development
and implementation of monitoring technologies and advanced process
control & optimization solutions. Jesus holds a PhD degree in Chemical
Engineering from McMaster University and has authored or co-authored
more than 40 peer-reviewed journal papers in the areas of multivariate
statistics and advanced process control among others. His team develops and implements
novel plant monitoring, machine learning, IIOT solutions to improve the efficiency and
reliability of Linde’s processes. Jesus’s team received the Artificial Intelligence and Advanced
Analytics Leadership 2020 award from the National Association of Manufacturers’
Manufacturing Leadership Council.
`

Note to the readers


Jupyter notebooks and Spyder scripts with complete code implementations are available for
download at https://github.com/ML-PSE/Machine_Learning_for_DPS. Code updates when
necessary, will be made and updated on the GitHub repository. Updates to the book’s text
material will be available on Leanpub (www.leanpub.com) and Google Play
(https://play.google.com/store/books). We would greatly appreciate any information about
any corrections and/or typos in the book.
`

Series Introduction
In the 21st century, data science has become an integral part of the work culture at every
manufacturing industry and process industry is no exception to this modern phenomenon.
From predictive maintenance to process monitoring, fault diagnosis to advanced process
control, machine learning-based solutions are being used to achieve higher process reliability
and efficiency. However, few books are available that adequately cater to the needs of
budding process data scientists. The scant available resources include: 1) generic data
science books that fail to account for the specific characteristics and needs of process plants
2) process domain-specific books with rigorous and verbose treatment of underlying
mathematical details that become too theoretical for industrial practitioners. Understandably,
this leaves a lot to be desired. Books are sought that have process systems in the backdrop,
stress application aspects, and provide a guided tour of ML techniques that have proven
useful in process industry. This series ‘Machine Learning for Process Industry’ addresses
this gap to reduce the barrier-to-entry for those new to process data science.

The first book of the series ‘Machine Learning in Python for Process Systems
Engineering’ covers the basic foundations of machine learning and provides an overview of
broad spectrum of ML methods primarily suited for static systems. Step-by-step guidance on
building ML solutions for process monitoring, soft sensing, predictive maintenance, etc. are
provided using real process datasets. Aspects relevant to process systems such as modeling
correlated variables via PCA/PLS, handling outliers in noisy multidimensional dataset,
controlling processes using reinforcement learning, etc. are covered. This second book of
the series is focused on dynamic systems and provides a guided tour along the wide range
of available dynamic modeling choices. Emphasis is paid to both the classical methods (ARX,
CVA, ARMAX, OE, etc.) and modern neural network methods. Applications on time series
analysis, noise modeling, system identification, and process fault detection are illustrated
with examples. Future books of the series will continue to focus on other aspects and needs
of process industry. It is hoped that these books can help process data scientists find
innovative ML solutions to the real-world problems faced by the process industry.

Books of the series will be useful to practicing process engineers looking to ‘pick up’ machine
learning as well as data scientists looking to understand the needs and characteristics of
process systems. With the focus on practical guidelines and real industrial case studies, we
hope that these books lead to wider spread of data science in the process industry.
`

Previous book(s) from the series


(https://MLforPSE.com/books/)
`

Preface
Model predictive control (MPC) and real-time optimization (RTO) are among the most critical
technologies that drive the process industry. Any experienced process engineer would vouch
that the success of MPCs and RTOs depend heavily on the accuracy of the underlying
process models. Similarly, the key requirement for other important process technologies like
dynamic data reconciliation, process monitoring, etc. is availability of accurate process
models. Modeling efforts during commissioning of these tools can easily consume up to 90%
of the project cost and time. Modern data revolution, whereby abundant amount of process
data are easily available, and practical difficulties in building high-fidelity first-principles
dynamic models for complex industrial processes have popularized the usage of empirical
data-driven/machine learning (ML) models. Building dynamic models using process data is
called system identification (SysID) and it’s a very mature field with extensive literature.
However, it is also very easy for a process data scientist (PDS) new to this field to get
overwhelmed with the SysID mathematics and ‘drowned’ in the sea of SysID terminology.
Several noteworthy ML books have been written on time-series analysis; however, in process
industry, input-output models are of greater import. Unfortunately, there aren’t many books
that cater to the needs of modern PDSs interested in dynamic process modeling (DPM)
without weighing them down with too much mathematical details and therein lies our
motivation for authoring this book: specifically, a reader-friendly and easy to understand book
that provides a comprehensive coverage of ML techniques that have proven useful for
building dynamic process models with focus on practical implementations.

It would be clear to you by now that this book is designed to teach working process engineers
and budding PDSs about DPM. While doing so, this book attempts to avoid a pitfall that
several generic ML books fall into: overemphasis on ‘modern’ and complex ML techniques
such as artificial neural networks (ANNs) and undertreatment of classical DPM methods.
Classical techniques like FIR and ARX still dominate the dynamic modeling solutions offered
by commercial vendors of industrial solutions and are no less ‘machine-learning’ than the
ANNs. These two along with other classical techniques (such as OE, ARIMAX, CVA) predate
the ANN-craze era and have stood the test of time in providing equal (if not superior)
performance compared to ANNs. Correspondingly, along with modern ML techniques like
RNNs, considerable portion of the book is devoted to classical dynamic models with the
emphasis on understanding the implications of modeling decisions such as the impact of
implicit noise model assumption with ARX model, the implication of differencing data, etc.
`

Guided by our own experience from building process models for varied industrial applications
over the past several years, this book covers a curated set of ML techniques that have proven
useful for DPM. The broad objectives of the book can be summarized as follows:
• reduce barrier-to-entry for those new to the field of SysID
• provide working-level knowledge of SysID techniques to the readers
• enable readers to make judicious selection of a SysID technique appropriate for their
problems through intuitive understanding of the advantages and drawbacks of
different methods
• provide step-by-step guidance for developing tools for soft sensing, process
monitoring, predictive maintenance, etc. using SysID methods

This book adopts a tutorial-style approach. The focus is on guidelines and practical
illustrations with a delicate balance between theory and conceptual insights. Hands-on-
learning is emphasized and therefore detailed code examples with industrial-scale datasets
are provided to concretize the implementation details. A deliberate attempt is made to not
weigh readers down with mathematical details, but rather use it as a vehicle for better
conceptual understanding. Complete code implementations have been provided in the
GitHub repository. Although most of the existing literature on SysID use MATLAB as the
programming environment, we have adopted Python in this book due to its immense
popularity among the broad ML community. Several Python libraries are now available which
makes DPM using Python convenient.

We are quite confident that this text will enable its readers to build dynamic models for
challenging problems with confidence. We wish them the best of luck in their career.

Who should read this book


The application-oriented approach in this book is meant to give a quick and comprehensive
coverage of dynamic modeling methodologies in a coherent, reader-friendly, and easy-to-
understand manner. The following categories of readers will find the book useful:

1) Data scientists new to the field of system identification


2) Regular users of commercial process modeling software looking to obtain a deeper
understanding of the underlying concepts
3) Practicing process data scientists looking for guidance for developing process modeling
and monitoring solutions for dynamic systems
4) Process engineers or process engineering students making their entry into the world of
data science
`

Pre-requisites
No prior experience with machine learning or Python is needed. Undergraduate-level
knowledge of basic linear algebra and calculus is assumed.

Book organization
Under the broad theme of ML for process systems engineering, this book is an extension of
the first book of the series (which dealt with fundamentals of ML and its varied applications
in process industry); however, it can also be used as a standalone text. To give due treatment
to various aspects of SysID, the book has been divided into three parts. Part 1 of the book
provides a perspective on the importance of ML for dynamic process modeling and lays down
the basic foundations of ML-DPM (machine learning for dynamic process modeling). Part 2
provides in-detail presentation of classical ML techniques and has been written keeping in
mind the different modeling requirements and process characteristics that determine a
model’s suitability for a problem at hand. These include, amongst others, presence of
multiple correlated outputs, process nonlinearity, need for low model bias, need to model
disturbance signal accurately, etc. Part 3 is focused on artificial neural networks and deep
learning. While deep learning is the current buzzword in ML community, we would like to
caution the reader against the temptation to deploy a deep learning model for every problem
at hand. For example, the models covered in Part 2 still dominate the portfolio of models
used in industrial controllers and can often provide comparable (or even superior)
performance compared to ANNs with relatively less hassle.

Symbol notation
The following notation has been adopted in the book for representing different types of
variables:
- lower-case letters refer to vectors (𝑥 ∈ ℝ𝑚×1 ) and upper-case letters denote matrices
(𝑋 ∈ ℝ𝑛×𝑚 )
- individual element of a vector and a matrix are denoted as 𝑥𝑗 and 𝑥𝑖𝑗 , respectively.
- any ith vector in a dataset gets represented as subscripted lower-case letter (e.g., 𝑥𝑖 ∈
ℝ𝑚×1 ). Its distinction from an individual element 𝑥𝑗 would be clear from the
corresponding context.
`

Installing Required Packages


In this book, SIPPY package (https://github.com/CPCLAB-UNIPI/SIPPY) is used for classical
dynamic modeling of input-output systems. Below are a few remarks regarding the
installation of the package
▪ The package code can be downloaded from its GitHub repository. You may put the
‘sippy’ folder provided in the package’s distribution in your working directory to use the
provided models
▪ To run the code provided in this book, Slycot package is not required
▪ Control package’s version should be < 0.9 (https://github.com/CPCLAB-
UNIPI/SIPPY/issues/48)
`

Table of Contents

• Part 1 Introduction and Fundamentals

• Chapter 1: Machine Learning and Dynamic Process Modeling 1

1.1. Process Systems Engineering, Dynamic Process Modeling, and Machine Learning
-- components of a dynamic process model
1.2. ML-DPM Workflow
1.3. Taxonomy of ML-based Dynamic Models
1.4. Applications of DPM in Process Industry

• Chapter 2: The Scripting Environment 15

2.1. Introduction to Python


2.2. Introduction to Spyder and Jupyter
2.3. Python Language: Basics
2.4. Scientific Computing Packages: Basics
-- Numpy
-- Pandas
2.5. SysID-relevant Python Libraries
2.6. Typical SysID Script

• Chapter 3: Exploratory Analysis and Visualization of Dynamic Dataset:


Graphical Tools 35

3.1. Visual Plots: Simple Yet Powerful Tools


3.2. Autocorrelation Function (ACF)
-- Examples on inferences drawn using ACF
3.3. Partial Autocorrelation Function (PACF)
3.4. Cross-correlation Function (CCF)
-- Examples on inferences drawn using CCF
3.5. Power Spectral Density (PSD) and Periodogram

• Chapter 4: Machine Learning-Based Dynamic Modeling:


Workflow and Best Practices 48

4.1. System Identification Workflow


4.2. Identification Test/Input Signal Design
-- Pseudo Random Binary Sequence (PRBS)
-- Generalized Binary Noise (GBN)
`

4.3. Data Pre-processing


-- (Measurement) Noise removal
-- Centering and scaling
-- Trend and drift removal
4.4. Model Structure Selection
4.5. Model ID and Performance Assessment
-- Model order selection
4.6. Model Quality Check and Diagnostics
-- Residual analysis
-- Transient response checks
-- Simulation response checks
-- Parameter error checks

• Part 2 Classical Machine Learning Methods for Dynamic Modeling

• Chapter 5: Time Series Analysis: Concepts and Applications 76

5.1. Time Series Analysis: An Introduction


5.2. Autoregressive (AR) Models: An Introduction
-- Model order selection
5.3. Moving Average (MA) Models: An Introduction
-- Model order selection
5.4. Autoregressive Moving Average (ARMA) Models: An Introduction
-- Model order selection
5.5. Monitoring Controlled Variables in a CSTR using ARMA Models
5.6. Autoregressive Integrated Moving Average (ARIMA) Models: An Introduction
-- Model order selection
5.7. Forecasting Signals using ARIMA

• Chapter 6: Input-Output Modeling – Part 1:


Simple Yet Popular Classical Linear Models 100

6.1. FIR Models: An Introduction


6.2. FIR Modeling of Industrial Furnaces
6.3. ARX Models: An Introduction
6.4. FIR Modeling of Industrial Furnaces
6.5. FIR and ARX MIMO Models

• Chapter 7: Input-Output Modeling – Part 2:


Handling Process Noise the Right Way 120

7.1. PEM Models


7.2. ARMAX Models: An Introduction
7.3. ARMAX Modeling of Distillation Columns
`

7.4. OE Models: An Introduction


7.5. Box-Jenkins Models: An Introduction
7.6. ARIMAX Models: An Introduction

• Chapter 8: State-Space Models: Efficient Modeling of MIMO Systems 138

8.1. State-Space Models: An Introduction


8.2. State-Space Modeling via CVA
-- Mathematical background
-- Hyperparameter selection
8.3. Modeling Glass Furnaces via CVA
8.4. Monitoring Industrial Chemical Plants using CVA
-- Process monitoring/fault detection indices

• Chapter 9: Nonlinear System Identification: Going Beyond Linear Models 158

9.1. Nonlinear System Identification: An Introduction


9.2. NARX Models: An Introduction
9.3. Nonlinear Identification of a Heat Exchanger Process Using NARX
9.4. Introduction to Block-Structured Nonlinear Models

• Addendum A1: Closed-Loop Identification: Modeling Processes Under Feedback 170

• Part 3 Artificial Neural Networks & Deep Learning

• Chapter 10: Artificial Neural Networks:


Handling Complex Nonlinear Systems 174

10.1. ANN: An Introduction


10.2. Modeling Heat Exchangers using FFNN-NARX
10.3. RNN: An Introduction
-- RNN outputs
-- RNN-based NARX topology
-- LSTM Networks
10.4. Modeling Heat Exchangers using LSTM
`

Part 1
Introduction & Fundamentals
Chapter 1
Machine Learning and Dynamic Process
Modeling: An Introduction

P
rocess industry operations are dynamic in nature. In complex process plants such as
oil refineries, 1000s of process measurements may be recorded every second to
capture crucial process trends. Plant engineers often employ dynamic process models
to predict future values of process variables in applications such as process control, process
monitoring, etc. Machine learning (ML) provides a convenient mechanism to bring together
the dynamic process modeling (DPM) needs and the large data resources available in modern
process plants.

This chapter provides an overview of what ML has to offer for DPM. This chapter also
addresses a dichotomy between ML community and DPM community. While the former
generally tends to claim that ML has been reduced to mere execution of ‘model-fitting’ actions,
the later vouches for the need of ‘experts’ to build ‘successful’ models. We will attempt to
reconcile these two differing viewpoints.

Overall, this chapter provides a whirlwind tour of how the power of machine learning is
harnessed for dynamic process modeling. Specifically, the following topics are covered
• Introduction to dynamic process modeling and the need for machine learning
• Typical workflow in a ML-based DPM (ML-DPM) project
• Taxonomy of popular ML-DPM methods and models
• Applications of DPM in process industry

Let’s now tighten our seat-belts as we embark upon this exciting journey of de-mystifying
machine learning for dynamic process modeling.

1
`

1.1 Process Systems Engineering, Dynamic


Process Modeling, and Machine Learning

Process industry is a parent term used to refer to industries like petrochemical, chemical,
power, paper, cement, pharmaceutical, etc. These industries use processing plants to
manufacture intermediate or final consumer products. As emphasized in Figure 1.1, the prime
concern of the management of these plants is optimal design and operations, and high
reliability through proactive process monitoring, quality control, data reconciliation, etc. All
these tasks fall under the ambit of process systems engineering (PSE).

Figure 1.1: Overview of industries that constitute process industry and the tasks process
systems engineers perform

The common theme among the PSE tasks is that they all rely on reliable dynamic
mathematical process models that can accurately predict the future state of the process using
current and past process measurements. Therefore, DPM is one of the defining skills of
process systems engineers. Process industry has historically utilized both first
principles/phenomenological and empirical/data-based models for DPM. While the former
models provide higher fidelity, the later models are easier to build for complex systems. The
immense rise in popularity of machine learning/data science in recent years and exponential
increase in sensor measurements collected at plants have led to renewed interest in ML-
based DPM. Several classical and ‘modern’ ML methods for DPM are at a process data
scientist’s disposal. The rest of the book will take you on a whirlwind tour of these methods.
Let’s now jump straight into the nitty-gritty of ML-DPM.
2
`

Components of a dynamic process model


In the context of DPM, there are three types of variables/signals in a process system as shown
in Figure 1.2. The measured signals that we desire to predict are termed outputs while the
measured signals that can be manipulated to influence the outputs are called inputs. In
industrial processes, these outputs are seldom solely influenced or completely explained by
inputs. This unexplained component is attributed to the noise signals which can manifest as
measurement noise or process noise (unmeasured disturbances or unmeasured signals that
impact the system are often the cause of process noise). In the pH neutralization process
example shown below, process noise corresponds to unmeasured fluctuations in the
wastewater acidity and/or flow which causes disturbances in the process output.

Figure 1.2: (a) Process system (and its dynamic model) with input, output, and noise signals (b) A pH
neutralization process broken down into its dynamic components

The impact of measurement and process noise can be clubbed together and explained via a
stochastic model as shown in the figure above. The resulting disturbance signal summarizes
all the uncertain characteristics of the process. The stochastic and deterministic models can
be estimated simultaneously as well as separately.

In the engineering community, the task of building mathematical models of a


dynamic system using measured data is called system identification (SysID).
Additionally, the task of modeling dynamic systems without input variables is
termed time-series analysis.

3
`

Dynamic modeling notation


In this book, we will focus on time-invariant discrete-time models wherein the signals will be
assumed to be recorded at regular sampling interval of T time units. The output y at time kT
(k is any integer) will be denoted as y(k). System identification therefore entails finding the
relationship between the three signals y(k), u(k), and v(k). For the pH example, a simple
discrete-time linear model could look like the following

𝑦̂𝑝𝐻 (𝑘) = 𝛼𝑦̂𝑝𝐻 (𝑘 − 1) + 𝛽𝑢𝑎𝑙𝑘𝑎𝑙𝑖𝑛𝑒 (𝑘 − 1)


𝑦𝑝𝐻 (𝑘) = 𝑦̂𝑝𝐻 (𝑘) + 𝑣(𝑘) eq. 1

where α and β are estimable model parameters and the disturbance variable, v(k),
summarizes all the uncertainties. Here, the value of the output at the kth time instant is
predicated upon the past values of both output and input, and the disturbance. In the later
chapters, we will study how to characterize v(k) using stochastic models.

We cannot emphasize enough the importance of proper handling of process


disturbance signals. When in hurry, you may be tempted to ignore the stochastic
component. However, doing so would only be inviting disappointment as you
may end up with biased deterministic models with unsatisfactory performance.
This interlink between stochastic and deterministic models would probably not
be obvious to beginner PDSs. By the time you finish this book, this connection
will become obvious.

Static vs dynamic model


Before we proceed further, let’s take a quick look at how a dynamic model differs from a static
model. Consider a SISO process in Figure 1.3 where a step change in input is induced and
the corresponding change in output is observed.

⋯ 𝑦𝑠𝑡𝑒𝑎𝑑𝑦 ⋯
transition
dynamics

Figure 1.3: Representative dynamic changes in a SISO process output upon a step change
in input

4
`

➢ In static model, we are only concerned with being able to predict ysteady
as the impact of the step change in u.
➢ On the other hand, in dynamic model, we care about the transition
dynamics as well.
➢ It is obvious that a dynamic model estimation is a more demanding
problem and the complexity only increases for multivariable systems
with stochastic components.

Validity of discrete-time models

It won’t be wrong to say that continuous-time description of process systems (which


are inherently continuous in nature) is more natural than discrete-time description.
However, in computer controlled industrial plants, signals from the underlying
continuous process are sampled and made available at discrete time-points.
Therefore, there is sound rationale for focusing on discrete-time models.

When using first principles approach, discrete-time model can be obtained as an


approximation as well as an exact description of the underlying process. For
example, consider the following differential equation

𝑑𝑦
= 𝑓(𝑦(𝑡), 𝑢(𝑡))
𝑑𝑡

Approximating the derivative via forward difference gives,


𝑦(𝑡 + 𝑇) − 𝑦(𝑡)
= 𝑓(𝑦(𝑡), 𝑢(𝑡)); 𝑇 𝑖𝑠 𝑠𝑎𝑚𝑝𝑙𝑖𝑛𝑔 𝑖𝑛𝑡𝑒𝑟𝑣𝑎𝑙
𝑇

⇒ 𝑦(𝑡 + 𝑇) = 𝑦(𝑡) + 𝑇𝑓൫𝑦(𝑡), 𝑢(𝑡)൯


𝑜𝑟
𝑡
𝑦(𝑘 + 1) = 𝑦(𝑘) + 𝑇 𝑓(𝑦(𝑘), 𝑢(𝑘)); 𝑘 =
𝑇
Discrete-time model

In an alternate scenario, if the input variables are constant between samples, then
an exact analytical discrete-time representation can be derived for linear processes.

5
`

1.2 ML-DPM Workflow

Figure 1.4 shows the typical steps involved in system identification. As you can see, SysID is
more than just curve fitting. Overall, there are five broad tasks: data collection, exploratory
data analysis, data pre-treatment, model identification, and model validation. Although we will
study each step in detail in Chapter 4, let’s take a quick overview:

• Data collection and exploratory data analysis: Availability of ‘proper’ data is


absolutely critical and the requirement of ‘richness’ of training data is indispensable. In
the previous section we saw that dynamic modeling is more demanding than static
modeling and consequently, there are more stringent requirements on training data for
dynamic modeling. Training data may be taken from historical database or fresh
experiments may be performed. The training inputs should be such that the output data
contains the dynamic variations of interest.

Exploratory data analysis (EDA) involves preliminary (and usually manual)


investigation of data to get a ‘feel’ of the system’s characteristics. The activities may
include generating some graphical plots to check the presence of trends, seasonality,
and non-stationarity in data. Inferences made during EDA help make the right choices
in the subsequent steps of SysID.

• Data pre-treatment: This step consists of several activities that are designed to
remove the portions of training data that are unimportant (or even detrimental) to model
identification. It may entail removal of outliers and noise, removal of trends, etc.
Alternatively, training data can also be massaged to manipulate the model’s accuracy
as suited for the end purpose of the model. For example, if the model is to be used for
control purpose, then the training data may be pre-filtered to bolster model’s accuracy
for high frequency signals. Overall, the generic guideline is that you have better
chances of a successful SysID with a better conditioned dataset.

• Model training: Model training is the most critical step in SysID and entails a few sub-
steps. First, a choice must be made on the type of disturbance model and deterministic
model. The end use of the model, the available a priori system knowledge, and the
desired degree of modeling complexity dictate these selections. For example, if the
model is to be used for simulation purposes, then OE1 structure may be preferred over
ARX; if process disturbance has different dynamics compared to process input, then

1
We will cover these model structures in the upcoming chapters
6
`

ARMAX will be preferable; if computational convenience is sought, then ARX is usually


the first choice and is preferred over other complex structures such as recurrent neural
networks. Model structure selection is followed by model parameter estimation. This
sub-step is mostly ‘hands-off’ due to the availability of several specialized libraries that
perform parameter estimation.

Representative illustrations

Time plots

detrending

ARX modeling

𝑦(𝑘) = 0.6𝑦(𝑘 − 1) + 0.7𝑢(𝑘 − 3) + 𝑒(𝑘)

Step response check

Figure 1.4: Steps (with sample sub-steps) involved in a typical ML-based dynamic modeling

7
`

• Model validation: Once a model has been fitted, the next step is to check if the model
truly represents the underlying process. Several techniques are at a modeler’s
disposal. For example, you could check the model’s performance on a dataset that has
not been used during parameter estimation, plot the modeling errors to look for leftover
patterns, or check if the model agrees with the a priori information about the system.
Often, your first model will fail the validation procedure. An expert modeler can use the
validation results to infer the reasons for the failure. Some examples of the cause could
be
➢ Training data was not ‘rich’ enough
➢ Training data was not pre-treated adequately
➢ Choice of model structure was wrong
➢ Estimation algorithm did not converge

Once diagnosed, appropriate corrections are made, and the iterative procedure
continues.

We hope that you get the understanding that SysID is more than just black-box application of
modeling algorithm for estimation of model parameters. There are several practical aspects
that require active participation of the modeler during the SysID process. Without
exaggeration, we can say that SysID is an art, and the rest of the book will help you obtain
the necessary skills to become the SysID artist!

1.3 Taxonomy of ML-based Dynamic Models

The field of system identification is overwhelmingly extensive owing to the decades of


research that has led to the development of several specialized techniques. Figure 1.5 gives
an overview of some of the popular methods and models that we will cover in this book. These
models represent only a subset of all the SysID models out there and this selection is based
on our experience regarding the relevance of these models for process systems modeling.
We largely focus on time-invariant2, discrete-time models and these shown models can help
you handle a large majority of DPM problems you will encounter in process industry.

2
Models where time variable does not appear as an explicit variable.
8
`

Figure 1.5: Some popular SysID methods and models covered in this book

There are several noteworthy points in Figure 1.5. First, the apparent domination of linear
models: you may have expected nonlinear models to be preferable for modeling complex
industrial process systems, however, as it turns out, linear models are often justified for DPM.
The justification stems from the fact that industrial processes often operate around an optimal
point making the linear models pretty good approximation for usage in process control and
process monitoring applications. If the end use of the model is process simulation or design
where the system response over wide range of input variables is of interest, then nonlinear
models can prove to be more suitable. Within linear category, different modeling options exist
to cater to process systems with different characteristics, viz, multivariable outputs, presence
of correlated noise, disturbances sharing dynamics with inputs, presence of measurement
noise only, presence of drifts or non-stationarities, etc.

The classification at the root of linear model sub-tree is based on the methodology used for
model fitting. While PEM methods employ minimization of prediction errors, subspace
methods are based on matrix algebra and do not involve any optimization for parameter
optimization.3 Do not worry if these terms do not make much sense right now; they will soon
become ‘obvious’ to you. If not trained about the nuanced differences between these different
models and methods, you may not have much idea at the outset about which model would be
the best one for your system. This book will help you gain adequate conceptual understanding
to become adept at making the right choice and obtaining your coveted model quickly.

3
Another distinction is that PEM is used to obtain input-output models while SIM is used to obtain state-space models.
9
`

Types of models
In Eq. 1 we saw one way of representing a dynamic process model. The models from Figure
1.5 can be used to generate other representations of your dynamic systems; the figure below
shows the different forms/types of models that we will learn to derive in this book using
machine learning. We will also understand the pros and cons of these different model forms.

Figure 1.6: Different forms of dynamic process model (that we will learn to generate in this
book), their defining characteristics, and corresponding representative examples

10
`

Why careful choice of model matters: A simple illustration

Consider the shown process: 𝑒(k) white gaussian noise

u Process model:
y
𝑥(𝑘 + 1) + 𝑎𝑥(𝑘) = 𝑏𝑢(𝑘)

Assume true a=-0.8


true b=0.5

If not careful, you may just ignore the presence of measurement noise and attempt to fit
the following input-output model to estimate the model parameters a and b.

Fitted Model (ARX form): 𝑦(𝑘 + 1) + 𝑎 𝑦(𝑘) = 𝑏𝑢(𝑘)

Data file ‘simpleProcess.csv’ contains 1000 samples of u and y obtained from the true
process. Below are the parameter estimates we get using this data,

𝑎̂ = −0.6628 (± 0.016) , 𝑏෠ = 0.7174 (±0.035)


values in bracket denote standard errors

Two things are striking here: the estimates are grossly inaccurate, and the parameter
error estimates seem to suggest high confidence in these wrong values! What went
wrong in our approach? The reason is that the SNR (signal-to-noise ratio) value is not
very high (data was generated with SNR ~ 10) and the fitted ARX model is wrong input-
output form of the true process. The correct form would be the following

Correct input-output model

𝑥(𝑘 + 1) + 𝑎𝑥(𝑘) = 𝑏𝑢(𝑘)


𝑦(𝑘) = 𝑥(𝑘) + 𝑒(𝑘) ⇒ 𝑦(𝑘 + 1) + 𝑎 𝑦(𝑘) = 𝑏𝑢(𝑘) + 𝑒(𝑘 + 1) + 𝑎𝑒(𝑘)

Equation error is not white (as assumed in


ARX model) but colored!

Ignoring the presence of correlated equation error leads to biased (inaccurate)


parameter estimates. Hopefully, this simple illustration has convinced you against blind
application of ‘convenient’ models. Part II of this book will add several modeling tools
to your ML-DPM arsenal to help avoid such modeling mistakes.

11
`

1.4 Applications of DPM in Process Industry

In Figure 1.1, we saw some of the applications of dynamic models in process industry. To
provide further perspectives into how a typical plant operator or management may use these
varied applications, Figure 1.7 juxtaposes DPM applications alongside the typical decision-
making hierarchy in a process plant. Every step of plant operation is now-a-days heavily
reliant on DPM-based tools and machine learning has proven to be a useful vehicle for quickly
building these tools. You can use the models from Figure 1.5 for building these tools or if you
use commercial vendor solutions, you can find them employing these models in their products.
For example, in the process control field, FIR models have been the bedrock of industrial MPC
controllers. In the last few years, commercial vendors have inducted CVA models in their
offering due to the advantages provided by subspace models. The latest offering by Aspen,
DMC34, incorporates neural networks for MPC and inferential modeling. ARX, BJ models are
also used for industrial MPC5.

Figure 1.7: DPM applications in different layers of operational hierarchy

4
https://www.aspentech.com/en/products/msc/aspen-dmc3
5
Qin and Badgwell, A survey of industrial model predictive control technology. Control Engineering Practice, 2003
12
`

➢ The regulatory control layer primarily comprises of (PID) control valves.


Potential DPM applications may involve usage of soft-sensor for
estimation of difficult-to-measure controlled variables.

➢ The multivariable control layer usually consists of MPC and RTO


modules. Here, dynamic models representing multivariable relationships
between plant variables are used to ensure optimal operations of the
plant. Another interesting application is development of operator training
simulators (OTSs) for training plant operators.

➢ The process diagnostics layer ensures timely fault detection and


diagnostics. Here, process measurements can be compared against
predictions from dynamic models to check for presence of process
abnormalities.

➢ The production scheduling layer has dynamic models to determine short-


term optimal production schedules using forecasts of product demand
and/or raw-material cost.

This concludes our quick attempt to establish the connection between process industry,
dynamic process modeling, and machine learning. It must now be obvious to you that modern
process industry relies heavily on dynamic process modeling to achieve its objectives of
reducing maintenance costs, and increasing productivity, reliability, safety, and product
quality. ML-based DPM helps build tools quickly to facilitate achieving these objectives.

This introductory chapter has also cautioned against blind application of ‘convenient’ ML
models for dynamic modeling. Your process data will throw several questions at you at each
stage of system identification. No straightforward answers exist to these questions and only
some time-tested guiding principles are available. While the rest of the book will familiarize
you with these principles, the onus still lies on you to use your process insights and SysID

13
`

understanding to make the right modeling choices. And yes, remember the age-old advice6,
“All models are wrong, but some are useful.”

Summary

This chapter impressed upon you the importance of DPM in process industry and the role
machine learning plays in it. We familiarized ourselves with the typical SysID workflow,
explored its different tasks, and looked at different ML models available at our disposal for
model identification. We also explored the application areas in process industry where ML has
proved useful. In the next chapter we will take the first step and learn about the environment
we will use to execute our Python scripts containing SysID code.

6
Attributed to the famous statistician George E. P. Box. It basically implies that your (SysID) model will seldom exactly
represent the real process. However, it can be close enough to be useful for practical purposes.
14
`

Chapter 2
The Scripting Environment

I
n the previous chapter we studied the various aspects of system identification and learned
about its different uses in process industry. In this chapter we will quickly familiarize
ourselves with the Python language and the scripting environment that we will use to write
ML codes, execute them, and see results. This chapter won’t make you an expert in Python
but will give you enough understanding of the language to get you started and help understand
the several in-chapter code implementations in the upcoming chapters. If you already know
the basics of Python, have a preferred code editor, and know the general structure of a typical
SysID script, then you can skip to Chapter 3.

If you skim through the system identification literature, you will find almost exclusive usage of
MATLAB software as the computing environment. This is mostly attributed to the System
Identification toolbox, a very powerful MATLAB toolbox developed by Prof. Lennart Jung (a
legend in system identification). Unfortunately, this tool not freely available, and MATLAB is
not yet as popular as Python among the ML community. Luckily, several good souls in the
Python community have developed specialized libraries for all aspects of SysID. Most of the
popular SysID models can now be generated using off-the-shelf Python libraries. Considering
the dominance of Python for deep learning, Python becomes an excellent choice for SysID
scripting.

In the above context, we will cover the following topics to familiarize you to Python
• Introduction to Python language
• Introduction to Spyder and Jupyter, two popular code editors
• Overview of Python data structures and scientific computing libraries
• Python libraries for system identification
• Overview of a typical ML-DPM/SysID script

15
`

2.1 Introduction to Python

Python is a high-level general-purpose computer programming language that can be used for
application development and scientific computing. If you have used other computer languages
like Visual Basic, C#, C++, Java, then you would understand the fact that Python is an
interpreted and dynamic language. If not, then think of Python as just another name in the list
of computer languages. What is more important is that Python offers several features that
sets it apart from the rest of the pack making it the most preferred language for machine
learning. Figure 2.1 lists some of these features. Python provides all tools to conveniently
carry out all steps of an ML-DPM project, namely, data collection, data exploration, data pre-
processing, model ID, visualization, and solution deployment to end-users. In addition, freely
available tools make writing Python code very easy7.

Figure 2.1: Features contributing to Python language’s popularity

Installing Python
One can download official and latest version of Python from the python.com website.
However, the most convenient way to install and use Python is to install Anaconda
(www.anaconda.com) which is an open-source distribution of Python. Along with the core
Python, Anaconda installs a lot of other useful packages. Anaconda comes with a GUI called
Anaconda Navigator (Figure 2.2) from where you can launch several other tools.

7
Most of the content of this chapter is similar to that in Chapter 2 of the book ‘Machine Learning in Python for Process
Systems Engineering’ and have been re-produced with appropriate changes to maintain the standalone nature of this
book.
16
`

Figure 2.2: Anaconda Navigator GUI

Running/Executing Python code


Once Anaconda is installed, you can write your code in any text editor (like Notepad), save it
in .py format, and then run via Anaconda command terminal. However, a convenient
alternative is to use IDEs (integrated development environments). IDEs not just allow creating
.py scripts, but also execute them on the fly, i.e., we can make code edits and see the results
immediately, all within an integrated environment. Among the several available Python IDEs
(PyCharm, VS Code, Spyder, etc.), we found Spyder to be the most convenient and
functionality-rich, and therefore is discussed in the next section.

Jupyter Notebooks are another very popular way of writing and executing Python code. These
notebooks allow combining code, execution results, explanatory text, and multimedia
resources in a single document. As you can imagine, this makes saving and sharing complete
data analysis very easy.

In the next section, we will provide you with enough familiarity on Spyder and Jupyter so that
you can start using them.

17
`

2.2 Introduction to Spyder and Jupyter

Figure 2.3 shows the interface8 (and its different components) that comes up when you launch
Spyder. These are the 3 main components:

• Editor: You can type and save your code here. Clicking button executes the code
in the active editor tab.

• Console: Script execution results are shown here. It can also be used for executing
Python commands and interact with variables in the workspace.

• Variable explorer: All the variables generated by running editor scripts or console are
shown here and can be interactively browsed.

Figure 2.3: Spyder interface

Like any IDE, Spyder offers several convenience features. You can divide your script into cells
and execute only selected cell if you choose to (by pressing Ctrl + Enter buttons). Intellisense
allows you to autocomplete your code by pressing Tab key. Extensive debugging
functionalities make troubleshooting easier. These are only some of the features available in
Spyder. You are encouraged to explore the different options (such as pausing and canceling
script execution, clearing out variable workspace, etc.) on the Spyder GUI.

8
If you have used MATLAB, you will find the interface very familiar
18
`

With Spyder, you have to run your script again to see execution results if you close and reopen
your script. In contrast to this, consider the Jupyter interface in Figure 2.4. Note that the
Jupyter interface opens in a browser. We can save the shown code, the execution outputs,
and explanatory text/figures as a (.ipnb) file and have them remain intact when we reopen the
file in Jupyter notebook.

Figure 2.4: Jupyter interface

You can designate any input cell as a code or markdown (formatted explanatory text). You
can press Ctrl + Enter keys to execute any active cell. All the input cells can be executed via
the Cell menu.

This completes our quick overview of Spyder and Jupyter interfaces. You can choose either
of them for working through the codes in the rest of the book.
19
`

2.3 Python Language: Basics

In the current and next sections, we will see several simple examples of manipulating data
using Python and scientific packages. While these simple operations may seem unremarkable
(and boring) in the absence of any larger context, they form the building blocks of more
complex scripts presented later in the book. Therefore, it will be worthwhile to give these
atleast a quick glance.

Note that you will find ‘#’ used a lot in these examples; these hash marks are used to insert
explanatory comments in code. Python ignores (does not execute) anything written after # on
a line.

Basic data types


In Python, you work with 4 types of data types
# 4 data types: int, float, str, bool
i = 2 # integer; type(i) = int
f = 1.2 # floating-point number; type(f) = float
s = 'two' # string; type(s) = str
b = True # boolean; type(b) = bool

With the variables defined you can perform basic operations


# print function prints/displays the specified message
print(i+2) # displays 4
print(f*2) # displays 2.4

Lists, tuples as ordered sequences


Related data (not necessarily of the same data type) can be arranged together as a sequence
in a list as shown below
# different ways of creating lists
list1 = [2,4,6]
list2 = ['air',3,1,5]
list3 = list(range(4)) # equals [0,1,2,3]; range function returns a sequence of numbers starting
from 0 (default) with increments of 1 (default)
list3.append(8) # returns [0,1,2,3,8]; append function adds new items to existing list
list4 = list1 + list2 # equals [2,4,6,'air',3,1,5]
list5 = [list2, list3] # nested list [['air', 3, 1, 5], [0, 1, 2, 3,8]]
20
`

Tuples are another sequence construct like lists, with a difference that their items and sizes
cannot be changed Since tuples are immutable/unchangeable, they are more memory
efficient.

# creating tuples
tuple1 = (0,1,'two')
tuple2 = (list1, list2) # equals ([2, 4, 6, 8], ['air', 3, 1, 5])

A couple of examples below illustrate list comprehension which is a very useful way of creating
new lists from other sequences

# generate powers of individual items in list3


newList1 = [item**2 for item in list3] # equals [0,1,4,9,64]

# nested list comprehension


newList2 = [item2**2 for item2 in [item**2 for item in list3]] # equals [0,1,16,81,4096]

Indexing and slicing sequences


Individual elements in a list can be accessed and modified as follows

# working with single item using positive or negative indexes


print(list1[0]) # displays 2, the 1st item in list1
list2[1] = 1 # list2 becomes [‘air’,1,1,5]
print(list2[-2]) # displays 1, the 2nd last element in list2

Note that Python indexing starts from zero. Very often, we need to work with multiple items of
the list. This can be accomplished easily as shown below.

# accessing multiple items through slicing


# Syntax: givenList[start,stop,step]; if unspecified, start=0, stop=list length, step=1
print(list4[0:3]) # displays [2,4,6], the 1st, 2nd, 3rd items; note that index 3 item is excluded

print(list4[:3]) # same as above


21
`

print(list4[4:len(list4)]) # displays [3,1,5]; len() function returns the number of items in list
print(list4[4:]) # same as above
print(list4[::3]) # displays [2, 'air', 5]
print(list4[::-1]) # displays list 4 backwards [5, 1, 3, 'air', 6, 4, 2]
list4[2:4] = [0,0,0] # list 4 becomes [2, 4, 0, 0, 0, 3, 1, 5]

Execution control statements


These statements allow you to control the execution sequence of code. You can choose to
execute any specific parts of the script selectively or multiple times. Let’s see how you can
accomplish these

Conditional execution Loop execution

# selectively execute code based on condition # compute sum of squares of numbers in list3
if list1[0] > 0: sum_of_squares = 0
list1[0] = 'positive' for i in range(len(list3)):
else: sum_of_squares += list3[i]**2
list1[0] = 'negative'
print(sum_of_squares) # displays 78
# list1 becomes ['positive', 4, 6]

Custom functions
Previously we used Python’s built-in functions (len(), append()) to carry out operations pre-
defined for these functions. Python allows defining our own custom functions as well. The
advantage of custom functions is that we can define a set of instructions once and then re-
use them multiple times in our script and project.

For illustration, let’s define a function to compute the sum of squares of items in a list

# define function instructions


def sumSquares(givenList):
sum_of_squares = 0
for i in range(len(givenList)):
sum_of_squares += givenList[i]**2

return sum_of_squares

# call/re-use the custom function multiple times


print(sumSquares(list3)) # displays 78

22
`

You might have noticed in our custom function code above that we used
different indentations (number of whitespaces at beginning of code lines) to
separate the ‘for loop’ code from the rest of the function code. This practice is
actually enforced by Python and will result in errors or bugs if not followed.
While other popular languages like C++, C# use braces ({}) to demarcate a
code block (body of a function, loop, if statement, etc.), Python uses
indentation. You can choose the amount of indentation but it must be consistent
within a code block.

This concludes our extremely selective coverage of Python basics. However, this should be
sufficient to enable you to understand the codes in the subsequent chapters. Let’s continue
now to learn about specialized scientific packages.

2.4 Scientific Computing Packages: Basics

While the core Python data-structures are quite handy, they are not very convenient for the
advanced data manipulations we require for machine learning tasks. Fortunately, specialized
packages like NumPy, SciPy, Pandas exist which provide convenient multidimensional
tabular data structures suited for scientific computing. Let’s quickly make ourselves familiar
with these packages.

NumPy

In NumPy, ndarrays are the basic data structures which put data in a grid of values.
Illustrations below show how 1D and 2D arrays can be created and their items accessed

# import numpy package & create a 2D array


import numpy as np
arr2D = np.array([[1,4,6],[2,5,7]])

# getting information about arr2D


print(arr2D.size) # returns 6, the no. of items
print(arr2D.ndim) # returns 2, the no. of dimensions
print(arr2D.shape) # returns tuple(2,3) corresponding
to 2 rows & 3 columns

23
`

# create a 1D array
arr1D = np.array([1,4,6])

# getting information about arr1D


print(arr1D.size) # returns 3, the no. of items
print(arr1D.ndim) # returns 1, the no. of dimensions
print(arr1D.shape) # returns tuple (3,) corresponding
to 3 items

Note that the concept of rows and columns do not apply to a 1D array. Also, you would have
noticed that we imported the NumPy package before using it in our script (‘np’ is just a short
alias). Importing a package makes available all its functions and sub-packages for use in our
script.

Creating NumPy arrays


Previously, we saw how to convert a list to a NumPy array. There are other ways to create
NumPy arrays as well. Some examples are shown below

# creating sequence of numbers


arr1 = np.arange(3, 6) # same as Python range function; results in array([3,4,5])
arr2 = np.arange(3, 9, 2) # the 3rd argument defines the step size; results in array([3,5,7])
arr3 = np.linspace(1,7,3) # creates evenly spaced 3 values from 1 to 7; results in
array([1., 4., 7.])

# creating special arrays


arr4 = np.ones((2,1)) # array of shape (2,1) with all items as 1
arr5 = np.zeros((2,2)) # all items as zero; often used as placeholder array at beginning of script
arr6 = np.eye(2) # diagonal items as 1

# adding axis to existing arrays (e.g., converting 1D array to 2D array)


print(arr1[:, np.newaxis])
>>>[[3]
[4]
[5]]

arr7 = arr1[:, None] # same as above

24
`

# combining / stacking arrays


print(np.hstack((arr1, arr2))) # horizontally stacks passed arrays
>>> [3 4 5 3 5 7]

print(np.vstack((arr1, arr2))) # vertically stacks passed arrays


>>> [[3 4 5]
[3 5 7]]

print(np.hstack((arr5,arr4))) # array 4 added as a column into arr5


>>> [[0. 0. 1.]
[0. 0. 1.]]

print(np.vstack((arr5,arr6))) # rows of array 6 added onto arr5


>>> [[0. 0.]
[0. 0.]
[1. 0.]
[0. 1.]]

Basic Numpy functions


NumPy provides several useful functions like mean, sum, sort, etc., to manipulate and analyze
NumPy arrays. You can specify the dimension (axis) along which data needs to be analyzed.
Consider the sum function for example

# along-the row sum # along the column sum


arr2D.sum(axis=0) # returns 1D array arr2D.sum(axis=1) # returns 1D array
with 3 items with 2 items

Executing arr2D.sum() returns the scalar sum over the whole array, i.e., 25.

Indexing and slicing arrays


Accessing individual items and slicing NumPy arrays work like that for Python lists

25
`

# accessing individual items


print(arr2D[1,2]) # returns 7

# slicing
arr8 = np.arange(10).reshape((2,5)) # rearrange the 1D array into shape (2,5)
print((arr8[0:1,1:3]))
>>> [[1 2]]

print((arr8[0,1:3])) # note that a 1D array is returned here instead of the 2D array above
>>> [1 2]

# accessing entire row or column


print(arr8[1]) # returns 2nd row as array([5,6,7,8,9]); same as arr8[1,:]
print(arr8[:, 4]) # returns items of 5th column as a 1D array
>>> [4 9]

An important thing to note about NumPy array slices is that any change made on sliced view
modifies the original array as well! See the following example

# extract a subarray from arr8 and modify it


arr8_sub = arr8[:, :2] # columns 0 and 1 from all rows
arr8_sub[1,1] = 1000
print(arr8) # arr8 gets modified as well!!
>>> [[ 0 1 2 3 4]
[ 5 1000 7 8 9]]

This feature becomes quite handy when we need to work on only a small part of a large
array/dataset. We can simply work on a leaner view instead of carrying around the large
dataset. However, situation may arise where we need to actually work on a separate copy of
subarray without worrying about modifying the original array. This can be accomplished via
the copy method.

26
`

# use copy method for a separate copy


arr8 = np.arange(10).reshape((2,5))
arr8_sub2 = arr8[:, :2].copy()
arr8_sub2[1, 1] = 100 # arr8 won’t be affected here

Fancy indexing is another way of obtaining a copy instead of a view of the array being indexed.
Fancy indexing simply entails using integer or boolean array/list to access array items.
Examples below clarify this concept

# combination of simple and fancy indexing


arr8_sub3 = arr8[:, [0, 1]] # note how columns are indexed via a list
arr8_sub3[1, 1] = 100 # arr8_sub3 becomes same as arr8_sub2 but arr8 is not modified here

# use boolean mask to select subarray


arr8_sub4 = arr8[arr8 > 5] # returns array([6,7,8,9]), i.e., all values > 5
arr8_sub4[0] = 0 # again, arr8 is not affected

Vectorized operations
Suppose you need to perform element-wise summation of two 1D arrays. One
approach is to access items at each index at a time in a loop and sum them.
Another approach is to sum up items at multiple indexes at once. The later
approach is called vectorized operation and can lead to significant boost in
computational time for large datasets and complex operations.
# vectorized operations
vec1 = np.array([1,2,3,4])
vec2 = np.array([5,6,7,8])
vec_sum = vec1 + vec2 # returns array([6,8,10,12]); no need to loop through index 0 to 3

# slightly more complex operation (computing distance between vectors)


vec_distance = np.sqrt(np.sum((vec1 - vec2)**2)) # vec_distance = 8.0

Broadcasting
Consider the following summation of arr2D and arr1D arrays
# item-wise addition of arr2D and arr1D
arr_sum = arr2D + arr1D

27
`

NumPy allows item-wise operation between arrays of different dimensions, thanks to


‘broadcasting’ where smaller array is implicitly extended to be compatible with the larger array,
as shown in the illustration below. As you can imagine, this is a very convenient feature and
for more details on broadcasting rules along with different example scenarios, you are
encouraged to see the official documentation9.

Pandas

Pandas is another very powerful scientific package. It is built on top of NumPy and offers
several data structures and functionalities which make (tabular) data analysis and pre-
processing very convenient. Some noteworthy features include label-based slicing/indexing,
(SQL-like) data grouping/aggregation, data merging/joining, and time-series functionalities.
Series and dataframe are the 1D and 2D array like structures, respectively, provided by
Pandas

# Series (1D structure) # Dataframe (2D structure)


import pandas as pd data = [[1,10],[1,8],[1,6]]
df = pd.DataFrame(data, columns=['id', 'value'])
data = [10,8,6] print(df)
s = pd.Series(data) >>>
print(s)
>>>

# dataframe from series


s2 = pd.Series([1,1,1])
df = pd.DataFrame({'id':s2, 'value':s}) # same as above

Note that s.values and df.values convert the series and dataframe into corresponding NumPy
arrays.

9
numpy.org/doc/stable/user/basics.broadcasting.html
28
`

Data access
Pandas allows accessing rows and columns of a dataframe using labels as well as integer
locations. You will find this feature pretty convenient.

# column(s) selection
print(df['id']) # returns column 'id' as a series
print(df.id) # same as above
print(df[['id']]) # returns specified columns in the list as a dataframe
>>> id
0 1
1 1
2 1

# row selection
df.index = [100, 101, 102] # changing row indices from [0,1,2] to [100,101,102] for illustration
print(df)
>>> id value
100 1 10
101 1 8
102 1 6

print(df.loc[101]) # returns 2nd row as a series; can provide a list for multiple rows selection
print(df.iloc[1]) # integer location-based selection; same result as above

# individual item selection


print(df.loc[101, 'value']) # returns 8
print(df.iloc[1, 1]) # same as above

Data aggregation
As alluded to earlier, Pandas facilitates quick analysis of data. Check out one quick example
below for group-based mean aggregation

# create another dataframe using df


df2 = df.copy()
df2.id = 2 # make all items in column 'id' as 2
df2.value *= 4 # multiply all items in column 'value' by 4
print(df2)
>>> id value
100 2 40

29
`

101 2 32
102 2 24

# combine df and df2


df3 = df.append(df2) # a new object is retuned unlike Python’s append function
print(df3)
>>> id value
100 1 10
101 1 8
102 1 6
100 2 40
101 2 32
102 2 24

# id-based mean values computation


print(df3.groupby('id').mean()) # returns a dataframe
>>> value
id
1 8.0
2 32.0

File I/O
Conveniently reading data from external sources and files is one of the strong forte of Pandas.
Below are a couple of illustrative examples.
# reading from excel and csv files
dataset1 = pd.read_excel('filename.xlsx') # several parameter options are available to customize
what data is read
dataset2 = pd.read_csv('filename.xlsx')

This completes our very brief look at Python, NumPy, and Pandas. If you are new to Python
(or coding), this may have been overwhelming. Don’t worry. Now that you are atleast aware
of the different data structures and ways of accessing data, you will become more and more
comfortable with Python scripting as you work through the in-chapter code examples.

30
`

2.5 SysID-relevant Python Libraries

In the previous chapter we saw several dynamic modeling options for SysID. We also saw
some of the pre-processing steps involved in data preparation and in the subsequent residual
assessment step. Technically, one can employ the previously described scientific packages
to implement the SysID algorithms, but it can be cumbersome and inconvenient. Fortunately,
the Python user-community has made available several libraries that make implementation of
the SysID algorithms very convenient. Figure 2.5 shows some of these libraries.

Figure 2.5: SysID-relevant Python packages10 and the corresponding available functionalities

You will find us using these packages heavily in the upcoming chapters. We understand that
many of the terms in the above figure may be alien to you right now, but we figured that it
would be good to give you a ‘feel’ of what Python has to offer for SysID.

Note that we did not include the celebrated Sklearn library in Figure 2.5 that offers
several generic ML-related functionalities such as dataset splitting,
standardization, scoring, etc. Our SysID scripts will make extensive use of
Sklearn library as well.

10
SIPPY: https://github.com/CPCLAB-UNIPI/SIPPY
SysIdent: https://sysidentpy.org/; https://github.com/wilsonrljr/sysidentpy
Pyflux: https://pyflux.readthedocs.io/en/latest/

31
`

The concluding message is that Python provides most of the tools for SysID that you may find
in other languages such as R and MATLAB.

2.6 Typical SysID Script

In Figure 1.4 in Chapter 1, we graphically portrayed different stages of a SysID exercise. Let’s
now see what a typical SysID script looks like. You will also understand how Python, NumPy,
and advanced packages are utilized for ML-DPM scripting. We will study several SysID
aspects in much greater detail in the next few chapters, but this simple script is a good start.
The objective of this simple script is to take data for an input and an output variable from a file
and build an ARX model between them. The first few code lines take care of importing the
libraries that the script will employ.

# import packages
from sippy import system_identification SIPPY provides ARX models
import numpy as np
import matplotlib.pyplot as plt
from sklearn.preprocessing import StandardScaler
from sklearn.metrics import r2_score
from statsmodels.graphics.tsaplots import plot_acf Used for model diagnostics

We studied NumPy before. SIPPY, Sklearn, and Statsmodels were introduced in previous
section. Another library11 that we see here is matplotlib12 which is used for creating
visualization plots. The next few lines of code fetch raw data and mean-center them.

# fetch data
data = np.loadtxt('InputOutputData.txt')
u = data[:,2:]; y = data[:,1:2] # first column is timestamp

# mean-center (pre-process) model variables


u_scaler = StandardScaler(with_std=False)
u_centered = u_scaler.fit_transform(u)
y_scaler = StandardScaler(with_std=False)
y_centered = y_scaler.fit_transform(y)

11
If any package/library that you need is not installed on your machine, you can get it by running the command pip
install <package-name> on Spyder console
12
Seaborn is another popular library for creating nice-looking plots
32
`

Here NumPy’s loadtxt function is used to read space-separated data in the file
InputOutputData.txt. The data get stored in a 2D NumPy array, data, where the 2nd and 3rd
columns contain data for the output and input variables, respectively. NumPy slicing is used
to separate the u and y data. Thereafter, variables are pre-processed to mean-center them.
Next, an ARX model13 is fitted and used to make predictions.

# fit ARX model and compare training predictions vs observations


Id_ARX = system_identification(y_centered, u_centered, 'ARX', ARX_orders=[3,3,2])
y_centered_pred = np.transpose(Id_ARX.Yid) # Yid gives predictions during identification

fitted model 𝑦(𝑘) − 0.98𝑦(𝑘 − 1) + 0.02𝑦(𝑘 − 2) + 0.12𝑦(𝑘 − 3) = 0.02𝑢(𝑘 − 1) + 0.06𝑢(𝑘 − 2) +


0.07𝑢(𝑘 − 3)

plt.figure()
plt.plot(y_centered, 'o', label='raw data')
plt.plot(y_centered_pred, '--', label='ARX fit')
plt.legend(), plt.xlabel('k'), plt.ylabel('y')

In the last step, model quality assessment is done.

# Assess model accuracy


print('Fit accuracy = ', r2_score(y_centered, y_centered_pred))
>>> Fit accuracy = 0.998

# plot ACF of model residuals


res = y_centered - y_centered_pred
plot_acf(res, lags=50)
plt.xlabel('lag')

The residual plot suggests that further model refinement is warranted. In the later chapters,
we will learn how this inference has been made and what recourses are at our disposal for
model refinement.

13
SIPPY: Model coefficients can be obtained via the G (or NUMAERATOR and DENOMINATOR) attribute(s) of the model
object. See SIPPY’s manual for more details.
33
`

Although there are many more advanced ML and SysID aspects, the above code is very
representative of what goes in a ML-DPM script. Hopefully, you also got a feel of the powerful
capabilities of the Sklearn and SIPPY libraries that help to encapsulate complex ML
algorithms within user-friendly functions.

Summary

In this chapter we made ourselves familiar with the scripting environment that we will use for
writing and executing ML scripts. We looked at two popular IDEs for Python scripting, the
basics of Python language, and learnt how to manipulate data using NumPy and Pandas. We
also looked at SysID-relevant libraries available in Python and saw what a typical SysID
Python script may look like. In the next chapter you will learn several graphical tools that are
utilized for preliminary investigation and visualization of dynamic dataset.

34
`

Chapter 3
Exploratory Analysis and Visualization of
Dynamic Dataset: Graphical Tools

I
n Chapter 1 we had remarked that system identification is an art. A part of the art lies in
making right inferences from exploratory analysis of data and model residuals via visual
plots. Yeah, you read that right: even with all the fancy algorithms at our disposal,
sometimes visual inspection of data is still the best tool for a quick assessment of dataset and
model validity. Visual plotting can often provide crucial clues about model structure and model
troubleshooting, and forms an important component of deductive phase of SysID. These plots
will be used repeatedly in the in-chapter illustrations in this book and therefore we thought it
would be best to introduce the concepts behind these graphical tools right away.

Visual plots can range from simple time plots to advanced spectral density plots. These may
help us make some quick educated judgement about data stationarity, deterministic vs
stochastic trends, presence of colored noise, whiteness of model residuals, etc. Don’t worry
if you don’t understand these dynamic modeling-specific jargons for now. We will focus on
generation and conceptual understanding of these plots in this chapter and learn inference-
making using these plots in the later chapters.

Specifically, we will cover these topics


• Autocorrelation and autocovariance plots
• Partial autocorrelation plots
• Cross-correlation and cross-covariance plots
• Spectrum, spectral density plots, periodogram

35
`

3.1 Visual Plots: Simple Yet Powerful Tools

In system identification, careful scrutiny of data plots forms a critical component right from the
initial step of exploratory data analysis (EDA) to the last step of model validation. Consider
plots a and b in Figures 3.1 which are time plots of output signals in two different scenarios.
Just a visual inspection makes it apparent that the raw output signals contain trends. One can
further infer that while plot a exhibits a deterministic trend, plot b exhibits a stochastic trend14.
Such assessment during EDA can help a process modeler select appropriate class of models
for their systems.

(a) (b)

(c) (d)

ACF PSD ACF PSD

Figure 3.1: Visual plots for time series data

Consider further the plots 3.1c and d. Here, the shown noisy signals could correspond to the
disturbance signals or the model residuals (difference between observations and model
predictions). Here, unlike the previous example, the time plots don’t provide any quick obvious
assessment. However, the derived visualizations, autocorrelation and spectral density plots
make the distinction between the two scenarios very evident. These plots confirm that the
shown signals have white noise and colored noise properties, respectively. If these were
model residuals, then non-zero autocorrelations in plot 3.1d immediately suggest inadequate
modeling. Moreover, the spectral density plot looks qualitatively similar to that of an
autoregressive (AR) process and therefore, an AR model could be attempted for the colored

14
We will see the details on the distinction between these two types of trends in Chapter 4.
36
`

residuals. Alternatively, if these were process disturbance signals, then the white-noise like
disturbance in plot 3.1c would encourage a process modeler to employ OE models15.

These were just a sample of the kind of inferences one can draw using visual plots. Before
we begin making use of these plots, it would be wise to understand the concepts behind them
and this chapter is devoted to this purpose. If you are already familiar with these plots, then
you can skip the rest of this chapter. Let’s begin with the autocorrelation plots.

Time-domain vs frequency-domain analysis


Broadly, there are two distinct approaches to modeling dynamic systems and
analyzing dynamic dataset: time-domain approach and frequency-domain
approach. The models that we have discussed so far are time-domain
models where the focus is on modeling future values as a function of the
past and present values. Such models are primarily employed for
predictions/forecasting and are popular among general DPM practitioners.

In the frequency-domain approach, the time-series signals are decomposed


into their Fourier representations (summation of sinusoidal components) and
the focus is on analyzing the output behavior of a system as a function of
input signal frequency. Frequency-domain approach renders itself quite
useful for characterizing bias and variance properties of models. Time-
domain models are easier to understand for new entrants to DPM and will be
the subject of focus in this book. Relevant frequency-domain concepts will be
touched upon wherever needed.

3.2 Autocorrelation Function (ACF)

In Figure 3.1, we saw how ACF plots can make the difference between time-series signals
very apparent. The inferences that can be drawn from these two ACF plots is even more
interesting: in series (d), the future values can be predicted using the past measurements
while in series (c), prediction of future values is not possible. How does ACF plots allow us to
make such inferences? To understand this, let’s revisit the classical concept of correlation.
You probably already know that correlation coefficient quantifies the linear relationship
between two variables and is given as follows

15
The rationale behind this statement will become clear to you in Chapter 7.
37
`

𝑁−1
෌𝑘=0 (𝑦(𝑘) − 𝑦̅) (𝑢(𝑘) − 𝑢
ഥ)
𝜌=
N is the number of samples;
ටσ𝑁−1 ̅)2 (𝑢(𝑘) − 𝑢
𝑘=0 (𝑦(𝑘) − 𝑦 ഥ )2
𝑢̅ and 𝑦̅ are sample means of
𝑢(𝑘) and 𝑦(𝑘), respectively

For a single time series y(k), correlation takes the form of autocorrelation

𝑁−1
෌𝑘=ℓ (𝑦(𝑘)−𝑦̅)(𝑦(𝑘−ℓ)−𝑦̅)
𝜌𝑦𝑦 (ℓ) = eq. 1
σ𝑁−1 ̅)2
𝑘=0 (𝑦(𝑘)−𝑦

N is the length of time series

Here, 𝜌𝑦𝑦 (ℓ) quantifies the linear relationship between lagged values of the time series ℓ
distance apart. For example, 𝜌𝑦𝑦 (2) measures the correlation between y(k) and y(k-2). The
plot (sample plot below) of different correlation coefficients versus lag ℓ is called
autocorrelation function or ACF.

ACF plot ACF properties


𝜌𝑦𝑦 (1)
➢ 𝜌𝑦𝑦 (0) = 1
𝜌𝑦𝑦 (ℓ) ➢ −1 ≤ 𝜌𝑦𝑦 (ℓ) ≤ 1
𝜌𝑦𝑦 (3) ➢ 𝜌𝑦𝑦 (ℓ) is symmetric (𝜌𝑦𝑦 (ℓ) =
𝜌𝑦𝑦 (−ℓ)) and therefore, ACF is
plotted usually only for ℓ ≥ 0.

In Eq. 1, there is an implicit assumption that y(k) and y(k- ℓ𝑠) are related in
the same way as y(k+q) and y(k+q- ℓ) for any q. Another assumption is that
the mean 𝑦̅ is invariant to the sampling location k. These assumptions result
in ACF being a function of only the distance ℓ and Eq. 1 being valid for only
stationary processes. We will learn more about stationarity in Chapter 4.

38
`

Example 3.1:
Consider the stochastic process below that generates time series y(k)

𝑦(𝑘) = 0.6𝑦(𝑘 − 1) + 𝑒(𝑘)

Data-file SimpleTimeSeries.txt contains 1000 observations of y(k). The code below


generates the ACF plot.

# import packages
import numpy as np
from statsmodels.graphics.tsaplots import plot_acf
import matplotlib.pyplot as plt

# read data
y = np.loadtxt('simpleTimeSeries.csv', delimiter=',')

# generate ACF plot


conf_int = 2/np.sqrt(len(y))
plot_acf(y, lags= 20, alpha=None)
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue') # confidence interval

The shaded region in the above ACF plot represents the (95%) confidence interval where
the autocorrelation coefficients are expected to fall into for a white noise signal (signals
whose values are uncorrelated). For the signal y(k), values are obviously correlated and
therefore, the coefficients are significant (lie outside the shaded region).

Significant autocorrelations indicate linear dependency of future values of a time series


on its past values. Hopefully, now you can answer the question we posed at the
beginning of this section about how ACF allows us to make inferences about
predictability in Figure 3.1.

Examples on inferences drawn using ACF

➢ Model structure selection:

Illustrations below show some sample ACF plots and the inferences that can be drawn
regarding potential model structure
39
`

a) b) c)

Inference Inference Inference

➢ Exponential decay of ACF values ➢ Sudden drop in ACF values ➢ ACF values fall very slowly
➢ Signal is potentially from an AR ➢ Signal is potentially from a MA ➢ Process is close to non-
process process stationarity

➢ Residual diagnostics:

Residuals are differences between observed and predicted values of a signal. Consider
the residual signal time plot and its ACF below

yobservations
𝑦(k)
+ residuals
𝜀(k)
ypredictions
- 𝜀(k)
𝜌𝜀𝜀 (ℓ)
𝑦̂(k)

Here, we observe that the ACF values are not significant and therefore the model (that
generated the predictions, 𝑦̂(𝑘)) has been able to capture all the linear relationships in
data, leaving no leftover pattern in the residuals.16

16
An un-normalized version of ACF, called autocovariance function (ACVF), also exists and is gives as 𝜎𝑦𝑦 (ℓ) =
1 𝑁−1
෌𝑘=ℓ (𝑦(𝑘) − 𝑦̅)(𝑦(𝑘 − ℓ) − 𝑦̅). However, the covariance coefficients are not bounded and therefore, utilized less
𝑁
compared to correlation coefficients.
40
`

White Noise

Now that we understand ACFs, let’s formally describe the term ‘white noise’ that we have
already used a few times. A stochastic sequence e(k) is referred to as white noise if its
samples have a probabilistic distribution with zero mean and finite variance (say 𝜎 2 ), and
the following theoretical ACF

𝜌𝑒𝑒 (ℓ)
1, ℓ = 0
𝜌𝑒𝑒 (ℓ) = ൜
0, ℓ ≠ 0

Therefore, samples of e(k) are serially uncorrelated random variables. In practice, the
autocorrelation coefficients may not be exactly zero but will be close to zero.
Nonetheless, it can be expected that 95% of the coefficients will lie within the ±2/ξ𝑁
band as shown in Example 3.1. Also note that although gaussian white noise is
commonly used, there are no constraints on the probability distribution of the samples.
Accordingly, you can encounter the following notation in SysID literature

𝑒(𝑘) ~ 𝑊𝑁(0, 𝜎2 ) or 𝑒(𝑘) ~ 𝐺𝑊𝑁(0, 𝜎2 )


(white noise) (gaussian white noise)

A related term is iid (independent and identically distributed) noise. Every iid sequence
is WN but not conversely. The easiest way to generate a white noise signal is to use
Numpy’s random normal function as follows

# import packages
import numpy as np, matplotlib.pyplot as plt

# generate GWN (1000 observations, mean 0, variance 1)


e = np.random.normal(loc=0, scale=1, size=1000)
plt.plot(e, 'black', linewidth=0.5)
plt.ylabel('White noise'), plt.xlabel('k')

The use of the term ‘white’ to describe such a noise stems from its spectral properties
which we will study shortly. Any noise signal that is not white is a ‘colored’ noise signal.
In essence, a white noise is perfectly unpredictable, i.e., no amount of past
observations can provide any clues about future observations. Nevertheless, such
signals are the basic building blocks for building complex models of disturbance
signals (more on this in Chapter 5).

41
`

3.3 Partial Autocorrelation Function (PACF)

Consider again the process in Example 3.1. The ACF plot suggests that y(k) and y(k-2) are
correlated (and so are y(k) and y(k-3) and so on). This seems to indicate some inconsistency
with the governing difference equation which relates only the successive samples y(k) and
y(k-1). However, it is easy to see that y(k) and y(k-2) end up being correlated because y(k-1)
and y(k-2) are directly correlated.

In time series analysis, knowing direct correlation helps to decide what terms should be part
of the governing difference equation during model structure selection. To compute the direct
correlation between y(k) and y(k-2), the effects of y(k-1) are ‘discounted’ or removed from
both y(k) and y(k-2). The correlation between the discounted variables gives the direct
correlation or, more formally, partial correlation. Algorithm below shows the procedure for
computation of partial (auto)correlation

Algorithm: Partial autocorrelation between y(k) and y(k-2)

1. Perform least squares fit between y(k) and y(k-1) as well as between y(k-2) and y(k-1) separately
2. Generate predictions from the least squares models and compute the following residuals

𝜖𝑦𝑘 = 𝑦𝑘 − 𝑦̂𝑘 and 𝜖𝑦𝑘−2 = 𝑦𝑘−2 − 𝑦̂𝑘−2

discounted variables

3. Partial autocorrelation coefficient 𝜑𝑦𝑦 (2) ≡ correlation between 𝜖𝑦𝑘 and 𝜖𝑦𝑘−2

The partial autocorrelation coefficient for lag 3 can be computed following the above algorithm
wherein the effects of y(k-1) and y(k-2) are discounted from y(k) and y(k-3). Other coefficients
42
`

can be computed similarly and plotted versus lags to give partial autocorrelation function
(PACF). Let’s revisit our earlier example.

Example 3.1 continued:

The code below generates the PACF plot.

# generate PACF plot


conf_int = 2/np.sqrt(len(y))
plot_pacf(y, lags= 20, alpha=None)
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue')

The PACF plot is along the expected lines. Only the coefficient at lag=1 is significant.
Note that at lag=1, PACF and ACF values are the same as there are no intermediate
variables. Moreover, PACF value at lag=0 is not defined but is often set to unity for
visualization purposes.

The utility of PACF should be clear to you now. Another interpretation of PACF is worth
mentioning. Suppose you fit the following (pth order) autoregressive model.

𝑦(𝑘) = 𝑎1 𝑦(𝑘 − 1) + 𝑎2 𝑦(𝑘 − 2) ⋯ + 𝑎𝑝 𝑦(𝑘 − 𝑝) + 𝑒(𝑘)

The coefficient or weight (𝑎𝑝 ) corresponding to the pth lagged regressor (y(k-p)) equals the
PACF value for lag p or 𝜑𝑦𝑦 (𝑝). Therefore, the lag corresponding to the last significant PACF
value in a PACF plot can indicate the number of terms to be used in an autoregressive model.
More on this later in the chapter on time series analysis.

43
`

3.4 Cross-correlation Function (CCF)

Cross-correlation measures the linear relationship between two sequences, say, u(k) and y(k),
and is estimated as

𝑁−1
෌𝑘=ℓ (𝑦(𝑘)−𝑦̅)(𝑢(𝑘−ℓ)−𝑢
ഥ)
𝜌𝑦𝑢 (ℓ) = eq. 2
ටσ𝑁−1 ̅)2 (𝑢(𝑘)−𝑢
𝑘=0 (𝑦(𝑘)−𝑦 ഥ )2

The plot of cross-correlation coefficients versus lag ℓ is called cross-correlation function.

Example 3.2: Consider the input-output process below

𝑦(𝑘) = 0.6𝑦(𝑘 − 1) + 0.7𝑢(𝑘 − 3) + 𝑒(𝑘)

Data-file SimpleInputOutput.txt contains 1000 observations of y(k) and u(k). The code
below generates the CCF plot.

# import packages
import numpy as np, matplotlib.pyplot as plt
from statsmodels.tsa.stattools import ccf

# read data
data = np.loadtxt('simpleInputOutput.csv', delimiter=',')
u = data[:,0]; y = data[:,1]

# compute CCF values for lags = -20 to 20


ccf_vals_ = ccf(y, u) # ccf for lag >= 0
ccf_vals_neg_lags = np.flip(ccf(u, y)) # ccf for lag -1000 to 0
ccf_vals = np.hstack((ccf_vals_neg_lags[-21:-1], ccf_vals_[:21])) 𝜌𝑦𝑢 (3)

# generate CCF plot


conf_int = 2/np.sqrt(len(y))
lags = np.arange(-20,21)
plt.plot(lags, ccf_vals) # no in-built analogue of plot_acf is provided by Stattools
plt.gca().axhspan(-conf_int, conf_int) # confidence interval

➢ −1 ≤ 𝜌𝑦𝑢 (ℓ) ≤ 1 CCF Properties


This property is used in the code above ➢ 𝜌𝑦𝑦 (ℓ) is asymmetric, i.e.,
to compute ccf values for lags <=0 𝜌𝑦𝑢 (ℓ) ≠ 𝜌𝑦𝑢 (−ℓ) and 𝜌𝑦𝑢 (ℓ) = 𝜌𝑢𝑦 (−ℓ)

44
`

Examples on inferences drawn using CCF17

➢ Model structure selection:

The CCF between u(k) and y(k) can give some crucial hints about the time delay (dead
time (d)) of the process18. Consider the following scenario and the fact that dead time is
the smallest value d with which u(k-1-d) influences y(k) directly.

𝜌𝑦𝑢 (ℓ)

Asymmetricity is due to the fact that past values of u(k) A peak at lag = 3 and insignificant CCF
are related to y(k) differently than the future values values for lag <=2
⇒ A good guess for d is 2

➢ Residual diagnostics:

If a model has adequately captured the relationship between input and output, then 𝜌𝜀𝑢 (ℓ)
between the residual (𝜖(𝑘)) and the input sequences (u(k)) should be nearly zero for
positive19 lags because 𝜖(𝑘) should not have any relationship with past input values.20

𝜌𝜀𝑢 (ℓ)

Model residuals are uncorrelated with input ⇒ no


effect of input remains in the residuals

17
Like ACF, CCF also has a covariance counterpart called cross-covariance function (CCVF) and is given as 𝜎𝑦𝑢 (ℓ) =
1 𝑁−1
෌𝑘=ℓ (𝑦(𝑘) − 𝑦̅)(𝑢(𝑘 − ℓ) − 𝑢̅). Note that N-ℓ could be set as denominator instead of N to get unbiased estimates.
𝑁
18
We will formally introduce the term dead time in Chapter 6. But we figured that if you already knew what dead time is
then you may appreciate this example.
19
Significant correlation for negative lags implies relation between residuals and future input values which is an indication
of closed-loop feedback (and not necessarily model inadequacy). We will learn more on this later.
20
A small caveat here is that either 𝜖(𝑘) or u(k) should be white to impose this condition
45
`

3.5 Power Spectral Density (PSD) and Periodogram

A dynamic signal’s properties can also be described in terms of its frequency contents, i.e.,
by decomposing the signal into sinusoidal components with different frequencies. The
analysis in frequency domain is also called spectral analysis and for the stochastic discrete-
time signals, the tool of choice is (power) spectral density plot that can provide a quick glimpse
of strength of different frequency components. For example, consider the following time series
and its spectral density plot. The spectral plot makes it easy to infer that the components with
frequencies 0.1Hz and 0.05Hz dominate the signal.

In our motivating illustration in Figure 3.1, we saw that the white noise signal has
approximately uniform contributions from all frequencies. Infact, this is a defining
characteristic of any white-noise signal (analogous to white light which is a mixture of all visible
frequencies of light). The common practice to generate PSD plots for sampled time-series
data is to use periodograms. Without going into the mathematical details, it suffices to state
that a periodogram plots the square of the magnitude of the Fourier transform as a function
of frequency, and therefore, shows how the intensity or power of a dynamic signal is
distributed across frequencies. Let’s see an instance of a PSD-based inference in the
following example.

Example 3.3:

We will consider the input and output time-series signals from Example 3.2, study their
spectral properties, and attempt to make some modeling-related inferences. The code
below generates the periodograms for the input and output signals
# import packages
import numpy as np, matplotlib.pyplot as plt
from scipy import signal

# read data
data = np.loadtxt('simpleInputOutput.csv', delimiter=',')
u = data[:,0]; y = data[:,1]

46
`

# input PSD
freq, PSD = signal.welch(u) Welch method estimates PSD as averaged
plt.figure(), plt.plot(freq, PSD) periodograms of overlapping segments of a signal;
plt.ylabel('input PSD'), plt.xlabel('frequency [Hz]') Averaging reduces noisy fluctuations in PSD values

# output PSD
freq, PSD = signal.welch(y)
plt.figure(), plt.plot(freq, PSD)
plt.ylabel('output PSD'), plt.xlabel('frequency [Hz]')

It is apparent from the comparison of the spectral densities that the process has low-pass
filter characteristics and therefore a model (such as ARX) with such characteristics can
be a good initial choice .

This concludes our quick look at some of the popular graphical tools for analyzing time series
data. Hopefully, you now have sufficient knowledge of these tools to understand their specific
applications in the upcoming chapters.

Summary

In this chapter we studied the concepts behind autocorrelation function (ACF), partial
autocorrelation function (PACF), cross-correlation function (CCF), and periodograms. We
also looked at some of the applications of these graphical tools. These tools come in handy
for analyzing time series and input-output data, and are a crucial part of the fundamentals
upon which you will develop your ML-DPM expertise. In the next chapter we will continue
building the fundamentals and look at some established guidelines for SysID.

47
`

Chapter 4
Machine Learning-based Dynamic Modeling:
Workflow and Best Practices

I
n Figure 1.4 in Chapter 1 we looked at a typical workflow for system identification. What is
noteworthy is that while model ID is only a part of this workflow, very often too much focus
goes into application of model ID to estimate model parameters at the expense of other
aspects of SysID. Dumping raw data into model ID module will invariably generate
unsatisfactory model if data is not pre-treated appropriately. Additionally, you will seldom be
right in your modeling choices in the very first attempt. The take-home message is that
knowledge about how to prepare raw data to enhance its information content about the
system, how to assess validity of obtained model, how to analyze modeling results critically,
and how to iterate judiciously is absolutely critical for successful SysID. Fortunately, several
guidelines and best practices have been devised to guide a process modeler at each step of
the SysID workflow. We will learn these guidelines and best practices in this chapter.

We will not cover the best practices associated with generic machine learning workflow.
Concepts like feature extraction, feature engineering, cross-validation, regularization, etc.
have already been covered in detail in our first book of the series. In this chapter our focus
will be on the unique challenges presented by dynamic processes and the specific best
practices to deal with them. Specifically, the following topics are covered

• Identification test design using PRBS and GBN signals


• Pre-treatment of raw data for removal of measurement noise, offsets, trends, and drifts
• Guidelines around selection of model structure
• Model order selection via AIC and cross-validation
• Model quality assessment via residual analysis, simulation response analysis, etc.

48
`

4.1 System Identification Workflow

So far in this book we have been consciously emphasizing the difference between model
identification and system identification. While model ID is all about estimating model
parameters, SysID is about ensuring that the model truly represents the underlying system
and stands consistent w.r.t. any prior available knowledge and any modeling assumptions.
Figure 4.1 reproduces the SysID workflow we had seen in Chapter 1 and shows the several
steps that serve to achieve the stated goals. The rest of the chapter will sensitize you about
these varied aspects of SysID and help you gain working-level understanding about how to
successfully execute a SysID project.

Figure 4.1: Typical steps in a SysID workflow that we will cover in this chapter

The first step of the workflow is data collection. Whether you are using pre-existing historical
data or conducting fresh identification tests, you must ensure that the dataset has enough
‘juice’ in it to enable identification of the desired model. We will soon see some guidelines
around this task. The next step corresponds to sanitizing the data to remove the unwanted
components that can negatively impact model ID. For example, elimination of any slow drift
in the output signals is essential to avoid incorrect model parameters. After the first two steps,
our dataset is ready and we come to model structure selection where the onus is on the
process modeler to choose the right class of process and noise models. We saw in Chapter
1 that an incorrect choice can lead to biased parameters estimates. Your expert domain
knowledge and any prior information on process disturbances can come in quite handy at this
49
`

step. For example, this is the step where you make a decision between ARX versus ARMAX,
or ANN versus CVA models. A generic thumb rule is to start with a simple model (like AR,
ARX) and then use inferences from model diagnostics to shortlist the next candidate model(s).

Once a model’s selection has been made, the model parameters can be estimated using off-
the-shelf Python packages. These packages also include functionalities for automatic
selection of optimal model order, e.g., the number of auto-regressive terms in an ARX model.
The estimated model must always undergo extensive check to ensure that the model is right
for your process system and is consistent with the modeling assumptions and prior process
knowledge. We will learn about several of these model quality checks later in the chapter. Any
model deficiency encountered will necessitate appropriate correction and another pass-
through the whole workflow. Let’s now learn about each of these tasks one-by-one.

4.2 Identification Test/Input Signal Design

The first and foremost requirement for a successful model ID is that the model training data
(whether historical or newly generated) must be informative. The traditional practice for fresh
data collection as observed in industry (especially for model development for control
purposes) is to induce step changes in each input separately and record the step responses.
Figure 4.2 shows an example. While these step tests are simple enough to be understood by
plant operators and provide good information on steady-state behavior of the process, there
are several shortcomings. When the process has several inputs, the step tests take a lot of
time and manpower. Moreover, step tests are known to not excite all the plant dynamics
significantly and therefore the risk of inaccurate model ID is high.

Input 1 (𝑢1 )

Input 2 (𝑢2 )

Input 3 (𝑢3 )

Time (mins)

Figure 4.2: Traditional open loop identification test strategy


50
`

The ideal identification test21 input signals should show a lot of fluctuations or excitations. Let’s
study two such signals, namely, PRBS and GBN.

Persistent Excitation

Consider the following process

𝑦(𝑘) = 𝑏1 𝑢(𝑘 − 1) + 𝑏2 𝑢(𝑘 − 2) + 𝑏3 𝑢(𝑘 − 3) + 𝑏4 𝑢(𝑘 − 4) + 𝑒(𝑘)

Suppose that the input signal is hypothetically of the form 𝑢(𝑘) = 𝑢(𝑘 − 1) + 1. Under
such an input signal, the process can be re-written as

𝑦(𝑘) = 𝑏1 𝑢(𝑘 − 1) + 𝑏2 𝑢(𝑘 − 1) − 𝑏2 + 𝑏3 𝑢(𝑘 − 1) − 2𝑏3 + 𝑏4 𝑢(𝑘 − 1) − 3𝑏4 + 𝑒(𝑘)


= 𝑏ሖ1 𝑢(𝑘 − 1) + 𝑏0

The above derivation implies that the process behaves virtually like a two-parameter
system and therefore the four original model parameters can’t be uniquely determined
with output data collected with the aforementioned input signal. In other words, the true
process model is not identifiable due to non-informative data. To ensure identifiability,
the input variables must be sufficiently excited. Mathematically, a discrete-time input
signal u(k) is said to be persistently exciting of order n (required to uniquely identify a
PEM model with ≤ 𝑛 model parameters) if the following conditions are met

The following limit exists The following matrix is invertible


𝑁
1 𝑟𝑢 (0) 𝑟𝑢 (1) ⋯ 𝑟𝑢 (𝑛 − 1)
𝑟𝑢 (𝜏) = lim ෍ 𝑢𝑡+𝜏 𝑢𝑡 𝑟 (−1) 𝑟𝑢 (0) ⋯ 𝑟𝑢 (𝑛 − 2)
𝑁 →∞ 𝑁 𝑅𝑢 (𝑛) = ൦ 𝑢 ൪
𝑡=0 ⋮ ⋮ ⋱ ⋮
𝑟𝑢 (1 − 𝑛) 𝑟𝑢 (2 − 𝑛) ⋯ 𝑟𝑢 (0)

You will mostly not use these theoretical conditions directly, but it’s worthwhile to know
these: a step input has persistent excitation (p.e.) of order 1; a full length PRBS has p.e.
of order M; a GBN signal and a white noise signal are persistently exciting with any finite
order. Alternatively, in frequency domain, u(k) is persistently exciting of order n if its
spectral density is not zero at n points in the interval (-𝜋, 𝜋].

21
Do not confuse between the process control literature term ‘identification test’ as used in the context of generating
data for model ID and the machine learning term ‘test data’ used in the context of model validation.
51
`

Pseudo Random Binary Sequence (PRBS)


A PRBS signal switches between two levels with varying pulse widths as shown below. While
the long width pulses help in estimation of steady-state gains, short pulses help in capturing
transient dynamics.

A PRBS signal of
order 6

With order n, a unique sequence of length M = 2n-1 can be generated. For larger signal length,
the unique sequence repeates itself and therefore, has a period of length M as shown in the
example below. Although a PRBS sequence is deterministic, for large M (and signal length
≥ 𝑀), the signal has white-noise like properties and hence the term ‘pseudo-random’ in its
name. Scipy library provides a function for PRBS generation. An example is shown below.

Example 4.1:

Let’s generate a PRBS signal for an input fluctuating between values -1 and 1.

# import packages
from scipy.signal import max_len_seq
import matplotlib.pyplot as plt

# generate PRBS input signal of order 6 and plot


PRBS_signal = max_len_seq(6, length=100)[0]*2-1 # converting
sequence of 0’s and 1’s to sequence of -1’s and 1’s

plt.plot(PRBS_signal, 'steelblue')
Unique sequence of length 63
plt.ylabel('PRBS_signal'), plt.xlabel('k')

Generalized Binary Noise (GBN)


A GBN signal is similar to PRBS but non-periodic. It switches between two values -a and a,
and the sequence is generated as follows

𝑃ሾ𝑢(𝑘) = −𝑢(𝑘 − 1)ሿ = 𝑝𝑠𝑤


; 𝑝𝑠𝑤 ∈ (0,1) is the switching probability
𝑃ሾ𝑢(𝑘) = 𝑢(𝑘 − 1)ሿ = 1 − 𝑝𝑠𝑤

52
`

For psw = 0.5, GBN signal has white-noise like properties. However, a lower value of psw (0.1
or 0.05) is often recommended. SIPPY provides a function for GBN signal generation. An
example is shown below.

Example 4.2:

Let’s generate a GBN signal for an input fluctuating between values -1 and 1.

# import packages
from sippy import functionset as fset psw=0.05
import matplotlib.pyplot as plt

# generate GBN input signal using SIPPY and plot


[gbn_signal, _, _] = fset.GBN_seq(1000, 0.1])
psw psw=0.1
plt.plot(gbn_signal, 'steelblue', linewidth=0.8)
plt.ylabel('GBN_signal'), plt.xlabel('k')

In the plots, note how lower switching probability


leads to higher pulse widths.

Persistence excitation is only a theoretical guarantee for model


identifiability. Other practical requirements also warrant careful attention.
➢ The physical levels of the test signals should be chosen large enough
so that variations in output is greater than the variations due to noise.
This property is quantified by a measure termed signal-to-noise ratio
(SNR). A low SNR leads to inaccurate parameter estimates. A few
words of caution here: If you are only interested in a linear model
around some operating point, then you need to be wary of unwanted
nonlinearities due to high test signal levels.
➢ If you are looking to build a nonlinear model, then the binary variations
in input signal levels will not expose system nonlinearity. The
level/amplitude of the test signal must also take a range of values.

53
`

4.3 Data Pre-processing

Raw process data is seldom suitable for immediate use for model ID, even if obtained through
well-designed identification tests. In this section, we will learn about some of the common
practices used to handle the impurities that inadvertently creep into our dataset. Let’s start
with removal of high-frequency measurement noise.

(Measurement) Noise removal


Consider the plot below which shows the observations of a temperature variable. Here, the
high frequency wiggles on top of the apparently systematic variations are measurement noise
and need to be removed before model ID. In time-domain, common methods for noise
removal are moving-average smoothing and SG filtering.22

High frequency components


mostly from noise

Another approach for noise removal is to work directly in frequency domain and filter out the
undesirable high-frequency components of the signal. A common choice for such a filter is
Butterworth filter23. The example below shows how to implement one such filter.

Example 4.3: Take the signal shown in the above motivating plot and clean it by removing
its high-frequency components. Note that the noisy signal was generated by adding a
white noise to the CO2 concentration signal in the celebrated Box-Jenkins gas furnace
dataset (https://openmv.net/info/gas-furnace).
# import packages
import numpy as np, matplotlib.pyplot as plt
from scipy import signal

# read data and generate its periodogram


y_noisy = np.loadtxt('noisySignal.csv', delimiter=',')
freq, PSD = signal.welch(y_noisy)
plt.plot(freq, PSD), plt.ylabel('PSD'), plt.xlabel('frequency [Hz]')

22
These were covered in detail in the first book of the series.
23
Such filters are called low-pass filters as they allow/retain low-frequency components in the cleaned signal.
54
`

# apply Butterworth filter of order 5 with critical frequency as 0.2 Hz


b, a = signal.butter(5, 0.2, 'low') # create the filter
y_cleaned = signal.filtfilt(b, a, y_noisy) # apply the filter
plt.figure(), plt.plot(y_cleaned, 'g'), plt.ylabel('y_cleaned'), plt.xlabel('k')

# periodogram of cleaned data


freq, PSD = signal.welch(y_cleaned)
plt.figure(), plt.plot(freq, PSD)
plt.ylabel('PSD cleaned'), plt.xlabel('frequency [Hz]')

We can see how efficiently the noisy component has been removed. In practice, you will
have to tune filter parameters cautiously so as to not filter out the useful components.

Centering and scaling


Dynamic models are often built to describe the behavior of the process around some desired
operating point. Therefore, in SysID literature, you will find the usage of deviation variables
which are defined as follows

𝑦(𝑘) = 𝑦𝑚 (𝑘) − 𝑦̅ ; 𝑢(𝑘) = 𝑢𝑚 (𝑘) − 𝑢̅

Where ym, um are the actual raw measurements and 𝑦̅, 𝑢̅ are the nominal values around which
the deviations are calculated. Models between y(k) and u(k) therefore relate the changes in
inputs to the changes in outputs. An obvious option is to assign values to 𝑦̅, 𝑢̅ (also called
offsets) corresponding to the desired steady-state operating point; however, this operating
point may not be known beforehand. The recommended and common approach is to use the
sample means as the offsets, i.e.,

𝑁−1 𝑁−1
1 1
𝑦̅ = ෍ 𝑦𝑚 (𝑘) ; 𝑢̅ = ෍ 𝑢𝑚 (𝑘)
𝑁 𝑁
𝑘=0 𝑘=0

Another pre-treatment best practice is to scale the deviation variables to account for the
differences in physical units of different variables. Scaling brings all the variables on an equal
basis and prevents any variable being given undue high weightage due to its numerically high
spread in values. A common choice is to use the standard deviation to scale any variable.
Both centering and scaling can be accomplished using Sklearn.24

24
Remember to transform the validation and test data using the same offset and scale determined using the model fitting
data
55
`

Trend and drift removal


Consider the signals from Figure 3.1 in Chapter 3. These could be output signals from a purely
stochastic process or disturbance signals from an input-output process as shown in the figure
below. What is noteworthy about these signals is that they exhibit meandering behavior and
don’t seem to oscillate around some mean values. Therefore, these qualify as non-stationary
signals. While signal A is said to have a trend, signal B shows a drift. In industrial processes,
changes in ambient temperature, presence of process leaks, etc., could cause such
disturbance signals. If these non-stationarities are not accounted for during SysID, inaccurate
parameter estimates may result. However, methods exist to make the non-stationary signals
stationary or remove the effect of non-stationarities from the input-output data. Let’s learn
these methods now.

Signal A

e(k) y(k)
Process

v(k)
Signal B

u(k) y(k)
Process

Figure 4.3: Non-stationary signals in a stochastic system and an input-output system

56
`

A quick primer on stationarity

Until now we have mentioned the term ‘stationarity’ a couple of times but haven’t defined
it rigorously. To understand this concept. Let’s consider the following difference equation
model fitted to the given data

eq. 1 𝑦(𝑘) = 0.6𝑦(𝑘 − 1) + 𝑒(𝑘)

A casual process modeler may not realize an implicit assumption being made on the
validity of the model for any value of k, i.e., there is some sort of consistency in the
behavior of the process irrespective of time. However, for the validity of such time-
invariant behavior, the random signal y(k) must exhibit identical statistical properties;
specifically, the mean and autocovariance (and therefore the variance as well) are
constant*. Such signals are called stationary signals.** To see the behavior on the other
side of the spectrum, consider the following non-stationary signals

Random walk with drift


Deterministic linear trend Random walk (stochastic trend)
𝒚(𝒌) = 𝒂 + 𝒃𝒌 + 𝒆(𝒌) 𝒚(𝒌) = 𝒚(𝒌 − 𝟏) + 𝒆(𝒌) 𝒚(𝒌) = 𝒚(𝒌 − 𝟏) + 𝒂 + 𝒆(𝒌)

Random walk with drift and


Deterministic quadratic trend deterministic trend Signal with ‘explosive behavior’
𝟐 𝒚(𝒌) = 𝜶𝒚(𝒌 − 𝟏) + 𝒆(𝒌); 𝜶 > 𝟏
𝒚(𝒌) = 𝒂 + 𝒃𝒌 + 𝒄𝒌 + 𝒆(𝒌) 𝒚(𝒌) = 𝒂 + 𝒃𝒌 + 𝒚(𝒌 − 𝟏) + 𝒆(𝒌)

Visually, signal (a) has an increasing mean and therefore is non-stationary. Signal (b)
***
has a constant mean but an increasing variance that tends to infinity. Its visual
characteristic is that it doesn’t revert to its mean as frequently as a stationary signal does.
Random walk is a simple process often used to demonstrate properties of non-stationary
signals. Therefore, remember this term and the process. You will see later that y(k) =
y(k-1) + e(k) can also be written as 𝑦(𝑘) = σ𝑘𝑗=0 𝑒(𝑗) and therefore such processes are
also called integrating processes or processes with integrating type non-stationarity. The
first five signals are further classified as homogeneous non-stationary because they can
be transformed into stationary signals by suitable differencing or transformations.
57
`

In summary, stationarity imparts some sort of ‘predictability’ and enable development of


models that could be used for prediction and forecasts. Attempts to fit stationary models
to nonstationary signals will lead to spurious results and therefore this aspect warrants
due caution from the process modeler. We will later study several qualitative and
quantitative tests of stationarity.

* Eq. 1 can be used to derive the properties of y(k). To see how, let’s derive the mean (𝜇(𝑘)) of the signal.

𝑦(𝑘) = 0.6𝑦(𝑘 − 1) + 𝑒(𝑘) = 0.6൫0.6𝑦(𝑘 − 2) + 𝑒(𝑘 − 1)൯ + 𝑒(𝑘) = 0.62 𝑦(𝑘 − 2) + 0.6𝑒(𝑘 − 1) + 𝑒(𝑘)
𝑗−1

= 0.6 𝑗 𝑦(𝑘 − 𝑗) + ෍ 0.6𝑖 𝑒(𝑘 − 𝑖) ሾafter j recursionsሿ


𝑖=0
𝑗−1

= 0 + ෍ 0.6𝑖 𝑒(𝑘 − 𝑖) ሾas j → ∞ሿ


𝑖=0

𝜇(𝑘) = 𝐸ሾ𝑦(𝑘)ሿ = ෍ 0.6𝑖 𝐸ሾ𝑒(𝑘 − 𝑖)ሿ ሾEሾ. ሿ denotes expectation of a signalሿ


𝑖=0
But 𝐸ሾ𝑒(𝑘 − 𝑖)ሿ = 0 ∀𝑖 𝑎𝑠 𝑒 ~ 𝑊𝑁 ⇒ 𝜇(𝑘) = 0 = 𝑐𝑜𝑛𝑠𝑡𝑎𝑛𝑡!

nd
** Theoretically, signals as described are called weakly stationary or covariance stationary as only 2 order moments have been
considered. Strict stationarity occurs when all the statistical properties are constant. However, for most of the practical purposes,
weak stationarity suffices and the qualification ‘weakly’ is omitted.

*** Repeated substitutions give 𝑣𝑎𝑟(𝑦(𝑘) = 𝑣𝑎𝑟(𝑒(𝑘)) + 𝑣𝑎𝑟൫𝑒(𝑘 − 1)൯ + ⋯ = 𝑘𝜎 2 + 𝑣𝑎𝑟൫𝑦(0)൯ ⇒ variance of y(k)
increases with k.

Detrending

As the method’s name suggests, this method aims to remove trends from the non-stationary
signals of the following type

𝑦(𝑘) = 𝑚(𝑘) + 𝑧(𝑘)

trend stationary
component component

58
`

The common practice for detrending is to fit (via least squares) a polynomial of an appropriate
order (say m(k) = a + bk + ck2 for quadratic order). The fitted polynomial is subtracted from
the time-series signal and then a stationary time-series model is built for the residuals. For,
the signal in Figure 4.4, the approach would look as follows

𝒎(𝒌) = 𝟎. 𝟏 + 𝟎. 𝟎𝟎𝟓𝒌

𝒛(𝒌) = 𝟎. 𝟖 ∗ 𝒛(𝒌 − 𝟏) + 𝒆(𝒌)

Figure 4.4: Breaking a signal into deterministic trend and stochastic residuals

Non-parametric method of detrending also exists and entail usage of moving average or low-
pass filter to remove the slow dynamic (trend) components from the non-stationary signals.

Classical time-series decomposition

The method of breaking down a signal into its trend and random component belongs to
a broader method called classical decomposition. Here, a signal y(k) is assumed to take
the following form
𝑦(𝑘) = 𝑚(𝑘) + 𝑠(𝑘) + 𝑧(𝑘)

trend random
component component

Here, the term s(k) represents the seasonal component to handle seasonal/periodic
variations in data. One such signal with all three components is shown below

Classical decomposition models are popular in financial data analysis. The prime focus
in this book is on I/O process models and therefore, seasonality is not considered.

59
`

Differencing

An alternative and more preferable approach to dealing with non-stationary signals is


differencing wherein consecutive samples of the signal are differenced to obtain stationary
signals25. Post differencing, any suitable stationary model can be fitted to the differenced
series. For example, consider a random walk process. Let z(k) be the differenced signal where

𝑧(𝑘) = 𝑦(𝑘) − 𝑦(𝑘 − 1)


⇒ 𝑧(𝑘) = 𝑒(𝑘) Stationary signal!

Sometimes differencing once is not enough and higher-order differencing may be needed to
produce stationary signals. For example, consider the following

𝑦(𝑘) = 2𝑦(𝑘 − 1) − 𝑦(𝑘 − 2) + 𝑒(𝑘)


⇒ 𝑧(𝑘) = 𝑦(𝑘) − 𝑦(𝑘 − 1) = 𝑦(𝑘 − 1) − 𝑦(𝑘 − 2) + 𝑒(𝑘)
⇒ 𝑧(𝑘) = 𝑧(𝑘 − 1) + 𝑒(𝑘)
⇒ 𝑧(𝑘) − 𝑧(𝑘 − 1) = 𝑒(𝑘) ⇒ Stationary signal obtained after
differencing 2 times

For input-output dataset, you won’t have access to the disturbance signal directly. The
recourse to get rid of non-stationarities in disturbance signals (v(k)) is to difference both the
input and output signals and build a model between the difference signals. An example is
shown below

∆𝑦(𝑘) = 𝑦(𝑘) − 𝑦(𝑘 − 1) ∆𝑢(𝑘) = 𝑢(𝑘) − 𝑢(𝑘 − 1)

∆𝑦(𝑘) = 0.3∆𝑦(𝑘 − 1) + 1.2∆𝑢(𝑘 − 1) + 𝑒(𝑘) ARX model fitted


between the differenced
signals

25
Such non-stationarity is referred to as homogeneous non-stationarity.
60
`

The above approach implicitly differences the disturbances and it can be shown that the
deterministic model between y and u is same as that between ∆𝑦 and ∆𝑢. We will see how
this happens in Chapter 7.

Detrending vs differencing
Differencing can also handle signals with deterministic trends. Two scenarios
are shown below

First order/single degree differencing Second order/second degree differencing


(handling linear trend) (handling quadratic trend)

𝑦(𝑘) = 𝑎 + 𝑏𝑘 + 𝑒(𝑘) 𝑦(𝑘) = 𝑎 + 𝑏𝑘 + 𝑐𝑘 2 + 𝑒(𝑘)

⇒ 𝑦(𝑘) − 𝑦(𝑘 − 1) = 𝑏 + 𝑒(𝑘) ⇒ 𝑦(𝑘) − 𝑦(𝑘 − 1) = (𝑏 − 𝑐) + 2𝑐𝑘 − 𝑒(𝑘 − 1) + 𝑒(𝑘)

Stationary with mean b 𝑧(𝑘)

⇒ 𝑧(𝑘) − 𝑧(𝑘 − 1) = 2𝑐 + 𝑒(𝑘 − 2) − 2𝑒(𝑘 − 1) + 𝑒(𝑘)

Stationary with mean 2c

In general, a polynomial trend of degree p can be handled through pth order


differencing.

Because differencing can handle trends and does not involve estimation of trend parameters,
it is preferred over detrending. However, differencing makes signals noisier26 and reduces the
SNR values, and therefore can result in inaccurate models. Therefore, one should not go
crazy with differencing! Over-differencing can do more harm than good. For process systems,
you will rarely need to go beyond 2nd degree differencing.

Detrending and differencing are not the only transformations out there. Sometimes taking
logarithms and then differencing can do the trick of making signals stationary. However,
simple differencing works well with most of the datasets. With this, we complete our quick look
at pre-treatment of dynamic signals.27 Next, we will look at some guidelines around candidate
model selection.

26
Differencing is equivalent to high-pass filtering
27
We have not covered outlier removal in this book. For dynamic dataset, outliers are handled via univariate outlier
removal methods on individual signals or on residuals (obtained after model fitting). The first book of the series covers
these methods in detail.
61
`

4.4 Model Structure Selection

Model structure selection refers to two subtasks:


a) Selection of the model type – for example, choosing between ARX, ARMAX, state-
space, RNN models, etc.
b) Choosing the size of the model – for example, the number of terms/parameters in
difference equation models, the order of the state-space model, the number of neurons
in a neural network model.
While systematic procedures exist for the later subtask, the former is very subjective and relies
heavily on the prior knowledge about the system. We had previously seen in Chapter 1 that a
wrong selection of model type can lead to inaccurate model parameters. Therefore, it is good
to be aware of some considerations that experienced process modelers make regarding
model type selection.

Principle of parsimony
Principle of parsimony should be your guiding mantra during model structure
selection. It states that you should not use any more parameters than
necessary for adequate representation of your process. The simple rationale
is that higher parameter dimensionality leads to greater chances of over-fitting
and bad predictive ability, and higher computational complexity. This advice
also translates to using the simplest model (and not necessarily the most
generic model) first that meets the modeling purposes.

Figure below lists some aspects that you may consider during model structure selection. To
keep our discussion simple, we will adopt a qualitative rather than quantitative approach.
Hopefully, this discussion will help you appreciate why we have so many model types and
make you pay more attention during model selection.

62
`

Figure 4.5: Considerations and insights that guide model structure selection28

Ease of estimation

Very often the choice of the model type is based on the ease with which a model can be
quickly specified and fitted. For example, models like ARX and FIR are linear-in-parameters
and therefore may be preferred over ARMAX or OE models which involve nonlinear
optimization for parameter optimization. Difference equations like ARX and ARMAX need
users to specify a number of model hyper-parameters such as the deadtime, the number of
regressive terms, etc. Alternatively, state-space models do not require much a priori
parameter specification.

In the upcoming chapters, you will learn the pros and cons of these different model types so
that you can judiciously decide if the modeling convenience over-weighs the model’s
shortcomings.

28
The meaning of independent and dependent parametrizations of stochastic and deterministic components will
become clear in Chapter 6.
63
`

End use of model

We had previously alluded to data pre-treatment techniques being dictated by the end use of
the model. However, the model’s end use also dictates the model type selection. For example,
if you are mainly interested in the deterministic portion of the process model (for say simulation
purposes), then you are better-off with OE models rather than ARX models. If you are building
a monitoring tool, then CVA models may be your preference. A good knowledge of a model’s
properties can help you decide if it suits your purpose or not.

Model bias considerations

As a process modeler, you should be aware of how your modeling choices influence the
consistency/bias/accuracy of your model. An incorrect specification of stochastic component
of the model can lead to biased parameter estimates of the deterministic component even if
you have correctly specified the deterministic model (as seen before in Chapter 1). You should
keep the following rules in mind (for open-loop and PEM models) to guide your modeling
choice29 30.

If both deterministic model (G) and


stochastic model (H) transfer operators Then unbiased parameter estimates are
are correctly specified obtained (assuming other conditions like
persistency are met)

If G is correct, H is wrong, and there are


some common parameters between the Then there will be a bias. The bias,
two transfer operators however, will diminish for high SNR.

If G is correct, H is wrong, but the two


transfer operators are parametrized Then an unbiased estimate of the
independently deterministic model can be obtained.

The takeaway message for now is that paying attention to stochastic component of the model
is not just some unnecessary exercise that can be ignored for convenience.

29
Close-loop scenario is dealt specifically in Addendum A1.
30
G and H transfer operators are introduced in Chapter 5.
64
`

Model bias and variance


Errors during SysID is often characterized via two terms, viz, variance and bias. Variance
refers to the variability in parameter estimates when model is fitted with different records
of data. Variance occurs due to noise and limited records of data. Infact, theoretically,
variance goes to zero for infinite amount data. You may have heard the statement “An
overfitted model has high variance”: it essentially means that an overfitted model’s
parameters may end up with significantly different values when trained with a different
training dataset.

Bias refers to the systematic errors due to deficiencies in the model structure. The model
cannot truly characterize the process and therefore, bias errors do not vanish even with
large training dataset. The statement “An underfitted model has high bias” simply means
that an underfitted model’s parameters are far away from their true values. In summary,
while variance quantifies the precision of parameter estimates, bias quantifies the
accuracy.

Consider the following scenario for illustration:

True Process
𝑦(𝑘) = 𝛼𝑦(𝑘 − 1) + 𝛽𝑢(𝑘 − 1) + 𝛾𝑢(𝑘 − 1)2 + 𝑒(𝑘)

Underfitted model Overfitted model


𝑦(𝑘) = 𝑎𝑦(𝑘 − 1) + 𝑏𝑢(𝑘 − 1) + 𝑒(𝑘) 𝑦(𝑘) = 𝑎𝑦(𝑘 − 1) + 𝑏𝑢(𝑘 − 1) + 𝑐𝑢(𝑘 − 1)2
+ 𝑑𝑢(𝑘 − 1)3 + 𝑒(𝑘)

Process characteristics

Very often the process characteristics and your insights about the process will help in model
type selection. For example, if you have reasons to believe that your process can be divided
into distinct linear and nonlinear blocks, then block-structured nonlinear models may be
preferred over NARX or ANNs. Furthermore, insights about the origin of nonlinearity can help
you further decide between Hammerstein and Wiener models. If your process has multiple
outputs, then state-space models may be preferred over difference-equation models for better
parameter efficiency.

When you will be introduced to the different model structures later, special focus would be on
highlighting specific properties of the models that make them more suitable to certain
processes.

65
`

Noise characteristics

Our discussion till now must have impressed upon you the interplay between the stochastic
and deterministic parts of a process model and the need to model process disturbances
carefully. Insights on where exactly noise enters the system (at the input, middle, or output of
the process) or whether the stochastic and deterministic parts share dynamics, etc. can help
you describe the impact of noise on the plant better and therefore obtain more accurate
models. If you don’t have much prior information on the process noise, then don’t worry; just
make your best guess on the model type and then iterate using inferences from model quality
checks.

As you work more with different model structures, you will naturally become better at model
structure selection. You will also begin to appreciate why there is such a large collection of
model types.

4.5 Model ID and Performance Assessment

Model ID entails estimation of parameters (denoted by vector θ) of the chosen model. This
problem can formally be presented as follows: let the following input-output data be given

𝑌 𝑁 = {𝑦(𝑘) = 𝑦(0), 𝑦(1), … , 𝑦(𝑁 − 1)}


𝑈 𝑁 = {𝑢(𝑘) = 𝑢(0), 𝑢(1), … , 𝑢(𝑁 − 1)}

and let 𝑦̂(𝑘) be the sequence of predicted values and 𝜀(𝑘) be the prediction error (also called
residuals)
𝜀(𝑘) = 𝑦(𝑘) − 𝑦̂(𝑘) eq. 1

Parameters θ are estimated by imposing certain conditions on the error sequence. For
example, PEM method tries to minimize the mean-squared values of 𝜀(𝑘), i.e.,

1
𝜃෠ = min ෍ 𝜀(𝑘)2
𝜃 𝑁
𝑘

Mean-squared prediction errors are also used to measure the performance of the model on
training data and validation/test data. Coefficient of determination (R2) is another popular
performance measure.

66
`

1-step ahead vs m-step ahead prediction

The error in Eq. 1 is formally defined as 1-step ahead error or 𝜀(𝑘|𝑘 − 1). This basically
implies that all past measurements up to time k-1 are utilized to generate predictions
𝑦̂(𝑘|𝑘 − 1) and then errors are computed. To see a potential problem with 1-step ahead
errors, consider the following trivial model

𝑦̂(𝑘) = 𝑦(𝑘 − 1) Prediction = last output measurement

For a slow changing process (which most of the process systems are), the above trivial
model can be deceptively impressive as shown below

𝒚(𝒌) = 𝟎. 𝟖𝒚(𝒌 − 𝟏) + 𝟎. 𝟑𝒖(𝒌 − 𝟏) + 𝒆(𝒌) ෝ(𝒌) = 𝒚(𝒌 − 𝟏)


𝒚

Trivial model

Conclusion: Good match between plant observations and 1-step ahead predictions should
not be the sole criteria of model adequacy check. Statistical analysis of errors is indispensable.

An alternative to 𝜀(𝑘|𝑘 − 1) during parameter estimation and performance assessment


is to use m-step ahead prediction errors, 𝜀(𝑘|𝑘 − 𝑚), where output measurements only
up to time k-m (i.e., y(k-m), y(k-m-1), …) are used and inputs up to time k-1 are used as
needed by the model. The model may use the predictions 𝑦̂ recursively to arrive at the
final 𝑦̂(𝑘|𝑘 − 𝑚).

Analyzing the long-range or m-step ahead predictions is one of the components of model
quality checks. As far as model fitting measure is concerned, 1-step ahead error is still
the popular choice primarily due to the ease of computation and eventual minimization.

67
`

Model order selection


For most models, you need to specify the model size/order before you perform model ID.
However, most likely, you would not know beforehand the correct size of your chosen model.
The common recourse is to experiment with different model orders and select the one that
minimizes the prediction errors. However, be careful that the prediction errors on the model
fitting dataset will monotonically decrease as you increase the model order or the number of
model parameters. The best practice, instead, is to use a fresh dataset, called validation
dataset, to assess the model’s performance on unseen data (not used during parameter
estimation) as shown in Figure 4.6 below. This approach is called cross-validation.

𝐽(𝜃) on validation dataset


• Inadequate • Too much
model flexibility in model
• High bias • High variance
• Underfitting • Overfitting

Model fitting/estimation dataset Model validation dataset

Figure 4.6: Cross-validation approach for dynamic modeling

You may notice that the samples in validation dataset are not obtained by
shuffling and randomly choosing samples from the training dataset (as is done
typically for static modeling). As should be obvious, this is done to maintain the
chronological order of observation samples in fitting and validation datasets.

Another related approach is to carve out multiple sets of validation datasets from your original
dataset and compute the performance measure as the average performance over these sets
as shown in Figure 4.7. This is called k-fold cross-validation.

68
`

Model training dataset

Fold 1 𝐽1 𝐽1 + 𝐽2 + 𝐽3
𝐽𝑣𝑎𝑙𝑖𝑑𝑎𝑡𝑖𝑜𝑛 =
3
Fold 2 𝐽2

Fold 3 𝐽3

Model fitting / estimation dataset Model validation dataset

Figure 4.7: Illustration of 3-fold cross-validation procedure

Model order selection via information criteria

A popular alternative to cross-validation for model order selection is to use performance


measure like Akaike information criteria (AIC) or Bayesian information criteria (BIC).

model performance model size

1
𝐴𝐼𝐶 (𝜃) = 𝑁 ln ൥ ෍ 𝜀 (𝑘, 𝜃)2 ൩ + 2𝑛
𝑁
𝑘

1
𝐵𝐼𝐶 (𝜃) = 𝑁 𝑙𝑛 ൥ ෍ 𝜀(𝑘, 𝜃)2 ൩ + 𝑛 ln (𝑁)
𝑁
𝑘

Where, n = number of model parameters


N = number of observations in training dataset

As you can see, these criteria try to find a balance between model accuracy and model
complexity. No separate validation dataset is used here, and the model order corresponding
to the minimum AIC (or BIC) is selected. Most of the SysID packages provide native support
for automated model order selection using these information criteria. You will see applications
of AIC-based SysID in the later chapters.

69
`

4.6 Model Quality Check and Diagnostics

The discussion in the previous section has taught us that ‘closeness’ between predicted and
measured outputs should not be construed as the sole definite proof of a ‘good’ model.
Instead, the model needs to be further scrutinized carefully to ascertain that the model has
truly picked up all the ‘predictable’ variations in the training dataset and adequately represents
the process. If otherwise, you can look for clues for further improvement. Let’s now look at
some of the model quality check activities.

Residual analysis
Residuals are essentially the part of model fitting data that could not be explained by the
model. Therefore, residual analysis entails checking that there remains no systematic
variation in the residual sequence; if it does then the leftover systematic variations can further
be modeled to improve the overall model predictions. The following two properties are desired
for 𝜀(𝑘)

1) 𝜀(𝑘) should be white noise, i.e., autocorrelation coefficients should be close to zero31
2) 𝜀(𝑘) should be uncorrelated to input u(k)32

For condition (1)33, ACF plot is generated (with about 20 lags). The correlation coefficients
(except for lag zero) are expected to be within some threshold - usually corresponding to 95%
significance level which is given by ±1.96/ξ𝑁. If condition (1) is violated, then it is implied that
the model could be improved further; however, no specific clues are provided about the
specific recourse for improvement. A generic advice is to try more complex stochastic model
for the disturbance signal.

𝐴𝐶𝐹

±1.96/ξ𝑁

No more than 5% of correlations can be outside this


band for condition (1) to be considered met

31
If the disturbance signals are not modeled (such as for OE models), then this condition is not checked.
32
Either of ε(k) or u(k) should be white for this condition.
33
Quantitative statistical tests (such as Ljung-Box test) also exist to check if the residuals indicate a lack of fit
70
`

For condition (2), CCF plot is generated along with thresholds (again, ±1.96/ξ𝑁 for 95%
confidence interval). If greater than 5% correlations (for lags > 0) violate the thresholds, then
it implies that there still exist some variations in 𝜀(𝑘) that stem from u(k) and therefore the
deterministic part of the model can further be improved. A hypothetical CCF plot below show
some examples of inferences drawn when condition (2) is not met34.

𝐶𝐶𝐹

terms u(k-2) and u(k-4) are


Significant correlations at negative lags imply missing from the model
process feedback or that residuals are correlated
to the future inputs. This is an indication that data
was collected from a closed-loop process where
output noise influences future process inputs.
[More on closed-loop ID in Addendum A1]

Residual analysis is often performed on the fitting dataset itself. It can be done on a fresh
validation dataset as well; however it will be more demanding for the model.

Transient response checks


It is a good practice to check the predicted step response or impulse response35 after model
fitting. If you have some prior insights about the process gain and/or time constant, then you
can compare your prior beliefs against what you observe in the transient response plots.
Mentioned below are some other scenarios where these plots can come in handy:

34
The rules of thumb: sharp peaks indicate missing input terms; slow-varying and consistent correlations outside the
confidence region indicate missing output terms in the model.
35
Step and impulse response of a process are introduced in Chapter 6.
71
`

• Assume you have several candidate models who provide similar prediction
responses. It is possible that the step responses from these models end up
being very different. This would indicate that some of the models are
obviously inaccurate and can help you reject them. Process insights, if
available, can be used to select the model(s) whose transient response(s)
seem more reasonable.

• Your model may give good predictive responses, but the step response may
end up showing unbounded steady-state values! If you know that your process
is inherently stable, then this implies wrong model.

• A good agreement between transient responses from a parametric model and


a non-parametric model can build confidence that essential features of the
process have been picked up by the model

Simulation response checks


Previously, we talked about m-step ahead predictions being preferable over the conventional
1-step ahead predictions for model adequacy analysis. This idea can be taken to the extreme,
resulting in infinite-step ahead predictions – also called as simulation. Simulation is often
performed on fresh data set and the output at any time k is generated using only the past
input measurements and initial conditions of the output. If model includes past output terms,
then simulated outputs are used recursively. Illustration below clarifies this concept.

Model: 𝑦(𝑘) = 0.8𝑦(𝑘 − 1) + 0.6𝑢(𝑘 − 1) + 𝑒(𝑘)


Initial condition: 𝑦(0) = 0
To predicted: 𝑦̂𝑆𝐼𝑀 (3)

𝑦̂𝑆𝐼𝑀 (1) = 0.8𝑦(0) + 0.6𝑢(0)

𝑦̂𝑆𝐼𝑀 (2) = 0.8𝑦̂𝑆𝐼𝑀 (1) + 0.6𝑢(1)

𝑦̂𝑆𝐼𝑀 (3) = 0.8𝑦̂𝑆𝐼𝑀 (2) + 0.6𝑢(2)

Disturbance contributions to output are ignored in generating 𝑦̂𝑆𝐼𝑀 .36 The utility of 𝑦̂𝑆𝐼𝑀 is that
if SNR is high and 𝑦̂𝑆𝐼𝑀 (𝑘) matches closely with y(k), then a good (deterministic) model is
implied. Do note that poor simulation performance may imply high disturbance levels and not

36
For models where disturbance signal is not modeled (such as OE, FIR), simulation is same as predictions
72
`

necessarily bad (deterministic) model. Nonetheless, if simulation does not catch the major
systematic variations in y(k), then the model is probably not good.

Example 4.4:
Consider the following actual process and candidate model. We will generate some
output data from the process and then analyze the simulated and 1-step ahead
predictions from the model.

Process: 𝑦(𝑘) = 0.3𝑦(𝑘 − 1) + 0.8𝑢(𝑘 − 1) + 0.2𝑢2 (𝑘 − 1) + 𝑒(𝑘)


Model: 𝑦(𝑘) = 0.8𝑦(𝑘 − 1) + 0.6𝑢(𝑘 − 1) + 𝑒(𝑘)
Initial condition: 𝑦(0) = 0

# import packages
import numpy as np, matplotlib.pyplot as plt

# define input signal (for illustration, let this be white noise)


N = 100
u = np.random.normal(0, 5, N)

# compute actual process output


y = np.zeros((N, ))
e = np.random.normal(0, 0.1, N) # measurement noise
for k in range(1, N):
y[k] = 0.3*y[k-1] + 0.8*u[k-1] + 0.2*u[k-1]*u[k-1] + e[k]

# compute model's simulated output and compare


y_sim = np.zeros((N, ))
for k in range(1, N):
y_sim[k] = 0.8*y_sim[k-1] + 0.6*u[k-1]

plt.plot(y, 'g', linewidth=0.8, label='Actual output')


plt.plot(y_sim, 'r', linewidth=0.8, label='1-step ahead predictions') (expectedly, very bad
plt.ylabel('y simulated'), plt.xlabel('k'), plt.xlim(0) , plt.legend() model performance)

# compute model's 1-step ahead predictions and compare


y_pred = np.zeros((N, ))
for k in range(1, N):
y_pred[k] = 0.8*y[k-1] + 0.6*u[k-1]

plt.plot(y, 'g', linewidth=0.8, label='Actual output')


plt.plot(y_pred, 'r', linewidth=0.8, label='1-step ahead predictions') (deceptively) pretty good
plt.ylabel('y predictions'), plt.xlabel('k'), plt.xlim(0) model performance!)

73
`

Simulation can sometimes throw surprising results as a result of model inaccuracy. For
example, simulated outputs may show divergent trend while 1-step ahead predictions may be
perfect! Furthermore, predicted outputs from two models may be very similar, but the
simulated responses can be significantly different.

Parameter error checks


Post model ID, the value of the parameetrs should be checked against their estimation error.
Ideally, the errors should be insignificant relative to the estimated parameter values. In
practice, a 95% confidence interval is generated for each parameter and if the confidence
interval includes 0, then that parameter is removed from the model. A new model excluding
the removed variables is re-identified.

This completes our quick look at the model diagnostics. There are a few other checks that we
did not cover such as pole-zero cancellation, stationarity checks using poles, invertibility
checks using zeros, etc. Overall, this chapter has equipped you with several tools to help you
along the SysID journey. We hope that you already feel comfortable that you have all the
necessary weapons in your arsenal to handle each step of the SysID process. We will end
this chapter with two advices. First, don’t forget that SysID is an iterative process and therefore
don’t get disheartened if your model fails in first attempt. Second, remember the famous
quote37 we alluded to in Chapter 1, “All models are wrong, but some are useful!”

Summary

In this chapter we learnt the best practices of setting up a system identification workflow. We
familiarized ourselves with practice-relevant concepts around identification test design, data
pre-treatment, model structure and order selection, and model quality checks. Next, we will
begin learning about arguably the most important and interesting task of SysID, i.e., model
identification.

37
Attributed to the famous statistician George E. P. Box.
74
`

Part 2
Classical Machine Learning Methods for Dynamic
Modeling

75
`

Chapter 5
Time Series Analysis: Concepts and
Applications

A
s alluded to before, time series analysis (TSA) refers to study of time series signals
from processes without exogenous inputs. Before we dive into the relatively more
complex world of input-output modeling, it would be prudent to first get acquainted with
how to model stochastic variations in signals and compactly describe the dependencies
among adjacent observations in a time series. The study of time series is not just for
pedagogical convenience. SysID derives many concepts from time series analysis and
therefore, a strong foundation in modeling time series is important for mastering the art of
SysID.

Time series analysis can help us to characterize I/O model residuals and get clues regarding
further model refinement. If your process has measured disturbance signals (inputs that can’t
be manipulated; for example, ambient temperature), then they can be modeled via TSA to
provide better forecasts and control. Furthermore, TSA can be used to model controlled
process variables and build process monitoring tools. In this chapter, we will work through
case-studies illustrating these applications.

Apart from setting a strong foundation of digital signal processing, this chapter will also
introduce the backshift notation and transfer function operator. These constructs are quite
useful for compact description and algebraic manipulation of the difference equations.
Specifically, the following topics are covered
• Introduction to AR, MA, and ARMA models for stationary signals
• Using ACF and PACF for model structure selection
• Monitoring controlled process variable in a CSTR using ARMA models
• Introduction to ARIMA models for nonstationary signals
• Forecasting measured signals using ARIMA models

76
`

5.1 Time Series Analysis: An Introduction

Time series analysis refers to the study and modeling of dependencies among sequential data
points in time series signals. Several approaches exist for modeling time series. In this
chapter, we will look at four of the most common models as shown in Figure 5.1. While AR,
MA, and ARMA models are used to describe stationary signals, ARIMA is used for
(homogeneous) nonstationary signals. In this chapter, we will understand the differences,
similarities, and the inherent connections between these models.

Figure 5.1: Commonly employed univariate time-series models

To further motivate the study of time series analysis, let’s briefly look at two of the use cases
that were mentioned previously. The illustration below shows a CSTR unit that has measured
disturbance signals (feed concentration and temperature). An accurate model for these
signals can help generate accurate forecasts and control the vessel temperature more
effectively. Also, it is easy to show that if the setpoint of the controllers do not change, then
the controlled variables (here, output product temperature and concentration) depend on
process disturbances alone. Therefore, a TSA model for these variables can be built to
eventually look for significant mismatch between measurements and model predictions as an
indicator of process faults.

77
`

Cooling jacket temperature is used to


control the reactor/product temperature
Continuous Stirred Tank Reactor
at optimal set-point

(Created by Daniele Pugliesi under Creative Commons Attribution-Share Alike 3.0,


https://commons.wikimedia.org/wiki/File:Agitated_vessel.svg)

5.2 Autoregressive (AR) Models: An Introduction

AR models are among the simplest and easiest to understand time series models, wherein
the current state is written as a linear combination of past measurements as shown below38

𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) − 𝑎2 𝑦(𝑘 − 2) ⋯ − 𝑎𝑝 𝑦(𝑘 − 𝑝) + 𝑒(𝑘) eq. 1

= σ𝑝𝑗=1 −𝑎𝑗 𝑦(𝑘 − 𝑗) + 𝑒(𝑘)

The above model uses p lagged/past values and therefore is referred to as an AR(p) model
or an autoregressive model of order p. In spite of its simplicity, an AR model can generate
varied patterns of signals as shown below. In process industry, processes with inherent
autoregressive behavior are fairly common.

𝑨𝑹(𝟏): 𝒂𝟏 = −𝟎. 𝟑 𝑨𝑹(𝟐): 𝒂𝟏 = −𝟎. 𝟑, 𝒂𝟐 = −𝟎. 𝟒𝟓 𝑨𝑹(𝟑): 𝒂𝟏 = −𝟎. 𝟑, 𝒂𝟐 = −𝟎. 𝟒𝟓,


𝒂𝟑 = 𝟎. 𝟐

𝑨𝑹(𝟏): 𝒂𝟏 = −𝟎. 𝟔 𝑨𝑹(𝟏): 𝒂𝟏 = −𝟎. 𝟗 𝑨𝑹(𝟏): 𝒂𝟏 = −𝟏

𝑵𝒐𝒏 − 𝒔𝒕𝒂𝒕𝒊𝒐𝒏𝒂𝒓𝒚

Figure 5.2: Time-series signals from AR processes

38
You will see soon why we have used ‘−𝑎𝑗 ’ and not ′𝑎𝑗 ′ in the equation
78
`

Model order selection


Given any time series data, the suitability of an AR model and its potential order can be judged
using the ACF39 and PACF plots as shown below for the AR(2) plot in Figure 5.2.

ACF plot PACF


plot
Characteristic Characteristic sharp
exponential decay decay to zero after
the pth lag

Let’s see an example which shows how to generate data from an AR process and how to fit
an AR model.

Example 5.1:
We will create an AR(2) signal with 1000 samples. Thereafter, guided by ACF/PACF, a
model will be fitted to the data followed by residual diagnostics.

# import packages
import numpy as np, matplotlib.pyplot as plt
from statsmodels.tsa.arima_process import ArmaProcess
from statsmodels.tsa.arima.model import ARIMA
from statsmodels.graphics.tsaplots import plot_acf, plot_pacf

# generate data for AR(2) process using statsmodels.tsa package


ar_coeffs = np.array([1, -0.3, -0.45]) # a1 = -0.3, a2 = -0.45
ARprocess = ArmaProcess(ar_coeffs)
y_AR = ARprocess.generate_sample(nsample=1000)

# generate ACF and PACF plots for y_AR ACF


conf_int = 2/np.sqrt(len(y_AR))
plot_acf(y_AR, lags= 20, alpha=None, title='')
plt.gca().axhspan(-conf_int, conf_int)

39
In general, the ACF plot for an AR process may also show damped sine waves in addition to damped exponentials
79
`

plot_pacf(y_AR, lags= 20, alpha=None, title='')


PACF
plt.gca().axhspan(-conf_int, conf_int)

The PACF plot clearly indicates an AR(2) process. We will again use the statsmodels.tsa
package to fit an AR(2) model.

# Fit an AR(2) model


y_AR_centered = y_AR - np.mean(y_AR)
model = ARIMA(y_AR_centered, order=(2, 0, 0)) # order = (p,d,r)
results = model.fit()
AR model is linear-in-parameters and
therefore, OLS method can be used to
# Print out the estimate for the parameters a1 and a2 estimate the unknown model parameters.
print('[a1, a2] = ', -results.arparams)

>>> [a1, a2] = [-0.27 -0.50]

The estimated parameters are close to the true values (the inaccuracy in the estimates
diminishes for larger sample size). With the obtained model, let’s generate the model
residuals and confirm whiteness of the residual sequence.

# get model predictions and residuals on training dataset


y_AR_centered_pred = results.predict()
residuals = y_AR_centered - y_AR_centered_pred

plt.figure(), plt.title('Training data')


plt.plot(y_AR_centered, 'g', label='Measurements')
plt.plot(y_AR_centered_pred, 'r', label='Predictions')
plt.ylabel('y(k): Measured vs predicted'), plt.xlabel('k'), plt.legend()

plt.figure(), plt.plot(residuals, 'black', linewidth=0.8)


plt.title('Training data'), plt.ylabel('residuals'), plt.xlabel('k')

# ACF residuals
plot_acf(residuals, lags= 20, alpha=None, title='')
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue', alpha=0.5)
plt.xlabel('lag'), plt.title('Autocorrelations')

80
`

Shift operator and transfer function operator

The original form of the difference equations that we have worked with so far is not very
convenient when combining different models and analyzing model properties. For a more
compact and useful representation, the concept of backshift operator (q-1) is introduced.
It is defined as

𝑦(𝑘 − 1) = 𝑞 −1 𝑦(𝑘)
Evidently, the backshift operator moves the signal one step back. Multiple applications
shift the signal back further

𝑞 −1 ൫𝑞 −1 𝑦(𝑘)൯ = 𝑞 −2 𝑦(𝑘) = 𝑦(𝑘 − 2)

Let’s rewrite Eq. 1 using the shift operator as follows

𝑦(𝑘) + σ𝑝𝑗=1 𝑎𝑗 𝑦(𝑘 − 𝑗) = 𝑒(𝑘)


⇒ 𝑦(𝑘) + ൫σ𝑝𝑗=1 𝑎𝑗 𝑞 −𝑗 ൯𝑦(𝑘) = 𝑒(𝑘)
⇒ ൫1 + σ𝑝𝑗=1 𝑎𝑗 𝑞 −𝑗 ൯𝑦(𝑘) = 𝑒(𝑘)
1
⇒ 𝑦(𝑘) = 𝑝 𝑒(𝑘) ≡ 𝐻(𝑞 −1 )𝑒(𝑘)
ቀ1+σ𝑗=1 𝑎𝑗 𝑞 −𝑗 ቁ

Let’s see how we would represent a simple ARX model 𝑦(𝑘) + 𝑎1 𝑦(𝑘 − 1) + 𝑎2 𝑦(𝑘 − 2) =
𝑏1 𝑢(𝑘 − 1) + 𝑏2 𝑢(𝑘 − 2) + 𝑒(𝑘) using the q notation

(1 + 𝑎1 𝑞 −1 + 𝑎2 𝑞 −2 )𝑦(𝑘) = 𝑞 −1 (𝑏1 + 𝑏2 𝑞 −1 )𝑢(𝑘) + 𝑒(𝑘)


⇒ 𝑦(𝑘) = 𝐺(𝑞 −1 )𝑢(𝑘) + 𝐻(𝑞 −1 )𝑒(𝑘) eq. 2

𝑞 −1 (𝑏1 + 𝑏2 𝑞−1 ) 1
1 + 𝑎1 𝑞 −1 + 𝑎2 𝑞−2 1 + 𝑎1 𝑞 −1 + 𝑎2 𝑞−2

Note that G(q-1) and H(q-1) are (input and noise transfer) operators (and not multipliers)
that operate on u(k) and e(k), respectively, and determine how the incoming signals are
‘transferred’ to the output. Therefore, G(q-1) and H(q-1) are called transfer operators.
Equation 2 can be written further as
𝑦(𝑘) = 𝑦𝑢 (𝑘) + 𝑣(𝑘)

deterministic disturbance
output signal

81
`

where, 𝑦𝑢 (𝑘) = 𝐺(𝑞−1 )𝑢(𝑘) eq. 3

𝑣(𝑘) = 𝐻(𝑞 −1 )𝑒(𝑘)

Note that Eq. 3 clearly shows that in an ARX model, the process disturbance v(k) is a
colored signal and not a white noise (e(k)). It is evident, therefore, that the transfer
operator form makes it easy to dissect the stochastic and deterministic parts of the model.

The q notation may not seem appealing to you immediately, but soon enough you will
begin to appreciate the convenience it offers! For now, just note that G(q-1) and H(q-1)
can be manipulated like polynomials of q-1 as you will soon see.

5.3 Moving Average (MA) Models: An Introduction

In MA models the current state is a summation of current and past white noise error values
as shown below

𝑦(𝑘) = 𝑐1 𝑒(𝑘 − 1) + 𝑐2 𝑒(𝑘 − 2) ⋯ + 𝑐𝑟 𝑒(𝑘 − 𝑟) + 𝑒(𝑘) eq. 4


= σ𝑟𝑗=1 𝑐𝑗 𝑒(𝑘 − 𝑗) + 𝑒(𝑘)

= ൫1 + σ𝑟𝑗=1 𝑐𝑗 𝑞 −𝑗 ൯𝑒(𝑘)

The above model is referred to as an MA(r) model. An MA model can be interpreted as a


counterpart of FIR models for time series signals where the effect of past random
shocks/noise are propagated directly to future values of the time series. Plots below provide
a sample of the patterns generated from MA models.

82
`

𝑴𝑨(𝟏): 𝒄𝟏 = 𝟎. 𝟑 𝑴𝑨(𝟐): 𝒄𝟏 = 𝟎. 𝟑, 𝒄𝟐 = 𝟎. 𝟒𝟓 𝑴𝑨(𝟑): 𝒄𝟏 = 𝟎. 𝟑, 𝒄𝟐 = 𝟎. 𝟒𝟓,


𝒄𝟑 = −𝟎. 𝟐

𝑴𝑨(𝟏): 𝒄𝟏 = 𝟎. 𝟔 𝑴𝑨(𝟏): 𝒄𝟏 = 𝟎. 𝟗 𝑴𝑨(𝟏): 𝒄𝟏 = 𝟏

𝑵𝒐𝒏 − 𝒊𝒏𝒗𝒆𝒓𝒕𝒊𝒃𝒍𝒆

Figure 5.3: Time-series signals from MA processes

Model order selection


Just like for AR model, ACF and PACF plots provide direct clues about the order of the model
as shown below for the MA(2) plot in Figure 5.3.

ACF plot PACF


plot
Characteristic sharp Characteristic
decay to zero after exponential decay
the qth lag and/or damped
sinusoidal waves

Let’s concretize our understanding of the MA process through an example.

Example 5.2: We will create an MA(2) signal with 1000 samples. Thereafter, guided by
ACF/PACF, a model will be fitted to the data followed by residual diagnostics. The
imported packages are the same as that in Example 5.1

# generate data for MA(2) process using statsmodels.tsa package


ma_coeffs = np.array([1, 0.3, 0.45]) # [1, c1, c2]
MAprocess = ArmaProcess(ma = ma_coeffs)
y_MA = MAprocess.generate_sample(nsample=1000)

83
`

# generate ACF and PACF plots for y_MA


ACF
conf_int = 2/np.sqrt(len(y_MA))
plot_acf(y_MA, lags= 20, alpha=None, title='')
plt.gca().axhspan(-conf_int, conf_int)

plot_pacf(y_MA, lags= 20, alpha=None, title='') PACF


plt.gca().axhspan(-conf_int, conf_int)

The ACF plot clearly indicates an MA(2) process. We will again use the statsmodels.tsa
package to fit an MA(2) model.

# Fit an MA(2) model


y_MA_centered = y_MA - np.mean(y_MA)
model = ARIMA(y_MA_centered, order=(0, 0, 2)) # order = (p,d,r)
results = model.fit()
Estimation of MA parameters is not as easy as that
for AR parameters because the unknowns, past
# Print out the estimate for the parameters c1 and c2 shocks (e) and coefficients (c), are non-linearly
print('[c1, c2] = ', results.maparams) present in the model. Therefore, iterative numerical
procedure is employed for parameter estimation.
>>> [c1, c2] = [0.30 0.53 ]

The estimated parameters are close to the true values (the inaccuracy in the estimates
diminishes for larger sample size). With the obtained model, let’s generate the model
residuals and confirm whiteness of the residual sequence.

# get model predictions and residuals on training dataset


y_MA_centered_pred = results.predict()
residuals = y_MA_centered - y_MA_centered_pred

plt.figure(), plt.title('Training data')


plt.plot(y_MA_centered, 'g', label='Measurements')
plt.plot(y_MA_centered_pred, 'r', label='Predictions')
plt.ylabel('y(k): Measured vs predicted'), plt.xlabel('k'), plt.legend()

plt.figure(), plt.plot(residuals, 'black', linewidth=0.8)


plt.title('Training data'), plt.ylabel('residuals'), plt.xlabel('k')

# ACF residuals
plot_acf(residuals, lags= 20, alpha=None, title='')
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue', alpha=0.5)
plt.xlabel('lag'), plt.title('Autocorrelations')

84
`

Equivalence between AR and MA models

AR and MA models may appear to be very different, but, under some conditions, they
are inter-convertible. Any stationary AR model can be rewritten as an MA(∞) model and
any invertible (definition of invertibility will be provided soon) MA model can be
equivalently rewritten as an AR(∞) model. For example, consider the MA(1) model y(k)
= c1e(k-1) + e(k), which can be rewritten as

𝑦(𝑘) = 𝑐1 (𝑦(𝑘 − 1) − 𝑐1 𝑒(𝑘 − 2)) + 𝑒(𝑘)


= 𝑐1 𝑦(𝑘 − 1) − 𝑐12 𝑒(𝑘 − 2) + 𝑒(𝑘)

⋮ after repeated substitutions


AR(∞) model! 𝑦(𝑘) = − ෍(−𝑐1 )𝑗 𝑦(𝑘 − 𝑗) + 𝑒(𝑘) eq. 5


𝑗=1

An alternative and quicker derivation:


𝑦(𝑘) = (1 + 𝑐1 𝑞 −1 )𝑒(𝑘)
using polynomial
⇒ (1 + 𝑐1 𝑞 −1 )−1 𝑦(𝑘) = 𝑒(𝑘)
long division
⇒ ൫σ∞ 𝑗 −𝑗
𝑗=0(−𝑐1 ) 𝑞 ൯𝑦(𝑘) = 𝑒(𝑘)

Note that Eq. 5 represents a valid/sensible model only if |c1| < 1 (otherwise c1j grows
unbounded). This is also the condition of invertibility for a MA(1) model. An AR(1) model
can be rewritten as MA(∞) model via recursive substitution of y(k-1), y(k-2), and so on.

ACF/PACF plots may sometime suggest both AR and MA models as adequate


representations of the underlying process. Given the equivalence between the two class
of models, you can choose either. Just keep a note that while AR parameters are easy
to estimate, MA model may be more parsimonious (i.e., require much fewer parameters).

85
`

5.4 Autoregressive Moving Average (ARMA)


Models: An Introduction

Sometimes a more compact and parsimonious model (compared to AR or MA models) can


be built by combining the autoregressive and moving average terms. Such models are called
ARMA models and take the following form

𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) ⋯ − 𝑎𝑝 𝑦(𝑘 − 𝑝) + 𝑐1 𝑒(𝑘 − 1) ⋯ + 𝑐𝑟 𝑒(𝑘 − 𝑟) + 𝑒(𝑘)

𝑝 𝑟

= ቌ− ෍ 𝑎𝑗 𝑞 −𝑗 ቍ 𝑦(𝑘) + ቌ෍ 𝑐𝑗 𝑞 −𝑗 ቍ 𝑒(𝑘) + 𝑒(𝑘) eq. 6


𝑗=1 𝑗=1

AR terms MA terms

The above model is called ARMA(p,r) due to the pth order autoregressive component and rth
order moving average component. It is apparent that AR and MA models are special cases of
ARMA model. Additionally, any stationary and invertible ARMA model can equivalently be
rewritten an AR(∞) or a MA(∞) model.

ARMA models are not just for mathematical convenience but are commonly encountered in
process industry. To see the reason, consider an example scenario below where output from
a pure AR process is contaminated by a random white noise disturbance

𝑒(k)

Process model:
y(k) = x(k) + e(k)
𝑥(𝑘) = 𝑎𝑥(𝑘 − 1)

𝑦(𝑘) = 𝑎൫𝑦(𝑘 − 1) − 𝑒(𝑘 − 1)൯ + 𝑒(𝑘)

⇒ 𝑦(𝑘) = 𝑎𝑦(𝑘 − 1) − 𝑎𝑒(𝑘 − 1) + 𝑒(𝑘)


Overall, an ARMA(1,1) process!

86
`

Plots below provide a sample of patterns generated from ARMA models.

𝑨𝑹𝑴𝑨(𝟏): 𝒂𝟏 = −𝟎. 𝟑, 𝒄𝟏 = 𝟎. 𝟑 𝑨𝑹𝑴𝑨(𝟐, 𝟏): 𝒂𝟏 = −𝟎. 𝟑, 𝒂𝟐 = −𝟎. 𝟒𝟓, 𝑨𝑹𝑴𝑨(𝟑, 𝟏): 𝒂𝟏 = −𝟎. 𝟑, 𝒂𝟐 = −𝟎. 𝟒𝟓,
𝒄𝟏 = 𝟎. 𝟑 𝒂𝟑 = 𝟎. 𝟐, 𝒄𝟏 = 𝟎. 𝟑

𝑨𝑹𝑴𝑨(𝟏, 𝟐): 𝒂𝟏 = −𝟎. 𝟑, 𝒄𝟏 = 𝟎. 𝟑, 𝑨𝑹𝑴𝑨(𝟐, 𝟐): 𝒂𝟏 = −𝟎. 𝟑, 𝒂𝟐 = −𝟎. 𝟒𝟓, 𝑨𝑹𝑴𝑨(𝟏, 𝟑): 𝒂𝟏 = −𝟎. 𝟑, 𝒄𝟏 = 𝟎. 𝟑,
𝒄𝟐 = 𝟎. 𝟒𝟓 𝒄𝟏 = 𝟎. 𝟑, 𝒄𝟐 = 𝟎. 𝟒𝟓 𝒄𝟐 = 𝟎. 𝟒𝟓, 𝒄𝟑 = −𝟎. 𝟐

Figure 5.4: Time-series signals from ARMA processes

Model order selection


ACF and PACF plots for the ARMA(2,2) plot in Figure 5.5 are provided below.

ACF plot PACF


plot

Both ACF and PACF plots tails off in exponential-like pattern (with
mixture of damped sine waves) which is characteristic of ARMA process

As is apparent, not much help is provided regarding the specific values of p and r. The general
recourse is to use model order selection techniques introduced in Chapter 4.

87
`

Example 5.3: We will create an ARMA(1,2) signal with 1000 samples. Thereafter, the
AR and MA orders will be automatically determined via AIC and the corresponding model
will be fitted to the data. The imported packages are the same as that in Example 5.1

# generate data for ARMA(1,2) process


ARMAprocess = ArmaProcess(ar=[1, -0.3], ma=[1, 0.3, 0.45])
y_ARMA = ARMAprocess.generate_sample(nsample=1000)

# generate ACF and PACF plots for y_ARMA


plot_acf(y_ARMA, lags= 20, alpha=None, title='')
plot_pacf(y_ARMA, lags= 20, alpha=None, title='') ACF PACF

The ACF and PACF plots are not very conclusive. Fortunately, the tsa package provides a
function arma_order_select_ic that can help estimate the orders via AIC.

# Determine the optimal AR and MA orders


from statsmodels.tsa.stattools import arma_order_select_ic

y_ARMA_centered = y_ARMA - np.mean(y_ARMA)


res = arma_order_select_ic(y_ARMA_centered, max_ma=4, ic=["aic"])
p, r = res.aic_min_order
print('(p, r) = ', res.aic_min_order)

>>> (p, r) = (1, 2) Orders correctly


identified!

# Fit an ARMA(p,r) model


model = ARIMA(y_ARMA_centered, order=(p, 0, r))
results = model.fit()
print('[a1] = ', -results.arparams); print('[c1, c2] = ', results.maparams)

>>> [a1] = [-0.29]


[c1, c2] = [0.30 0.53]

The estimated parameters are close to the true values. Next, the residuals are generated as in
the previous examples and whiteness of the residual sequence is confirmed.

88
`

5.5 Monitoring Controlled Variables in a CSTR using


ARMA Models

To illustrate a practical application of time series analysis, we will consider the continuous
stirred-tank reactor described in the chapter introduction. Here, the product temperature will
be monitored to ensure it is not deviating away from its optimal setpoint due to any process
fault. The datafile CSTR_controlledTemperature.csv contains 4 hours of temperature
measurements40 sampled at 0.1 seconds (totaling 2401 samples). A process fault occurs at
3.5 hours (around sample # 2100) causing a 20% decrease in the heat transfer coefficient.
Let’s see if this process fault causes any deviations in the product temperature and if our
monitoring methodology can detect these deviations.

Continuous Stirred Tank Reactor

Monitoring objective: Catch


unexpected deviations in product
temperature as soon as possible as
a leading indicator of process Cooling jacket temperature is used
and/or controller fault to control the reactor/product
temperature at optimal set-point

Scenario: A fault in the cooling


jacket leads to a step change
(decrease) in the heat transfer
coefficient

Figure 5.5: Process fault detection using TSA: case-study set-up41

Let’s start by importing the required packages and exploring the provided I/O dataset. The
first 3 hours of data will be used to build a model and the last 1 hour will be used as test data.

# import packages
import matplotlib.pyplot as plt, numpy as np, control
from statsmodels.graphics.tsaplots import plot_acf, plot_pacf
from statsmodels.tsa.stattools import arma_order_select_ic
from statsmodels.tsa.arima.model import ARIMA

40
The CSTR model provided at https://github.com/APMonitor/pdc/blob/master/CSTR_Control.ipynb is used to generate the data.
41 CSTR diagram created by Daniele Pugliesi under Creative Commons Attribution-Share Alike 3.0, https://commons.wikimedia.org/wiki/File:Agitated_vessel.svg

89
`

# read data and split into training and test data


T = np.loadtxt('CSTR_controlledTemperature.csv', delimiter=',')
T_train = T[:1800]; T_test = T[1800:]

Short-lived deviation in absolute


value at start of the process-fault

The plot above shows that the temperature seems to show only a short-lived42 deviation in its
absolute value due to the process fault. Therefore, on the basis of this time-plot alone, plant
operators could very well ignore this as an unimportant fluctuation and the process fault could
go unattended.

The trivial univariate monitoring approach of using 𝑚𝑒𝑎𝑛 ± 2 ∗ 𝑠𝑡𝑎𝑛𝑑𝑎𝑟𝑑 𝑑𝑒𝑣𝑖𝑎𝑡𝑖𝑜𝑛 bounds
would also be inadequate because this approach assumes that the samples are independent
of each-other, which as shown by the below ACF plot of T_train data, is certainly not true for
the product outlet temperature (and dynamic processes in general). The control chart shown
below shows the failure of this approach as the controlled variable does not show any
sustained unusual violations of the control bounds (bounds are computed using the training
data only).

Let’s now see if the time-series models can do a better job of fault detection. We will attempt
to fit an ARMA model.

42
The controller adjusts the jacket temperature to compensate for the reduction in the heat transfer coefficient.
90
`

# Determine the optimal AR and MA orders


T_train_centered = T_train - np.mean(T_train); T_test_centered = T_test - np.mean(T_train)
res = arma_order_select_ic(T_train_centered, max_ar=5, max_ma=5, ic=["aic"])
p, r = res.aic_min_order
print('(p, r) = ', res.aic_min_order)

>>> (p, r) = (2, 4)

# Fit an ARMA(p,r) model and get residuals


model = ARIMA(T_train_centered, order=(p, 0, r))
results = model.fit()
T_train_centered_pred = results.fittedvalues # same as results.predict()
residuals_train = T_train_centered - T_train_centered_pred # same as results.resid

The residuals pass the model quality check.

It is time now to use the fitted ARMA model for fault detection. The rationale is straight-forward:
if any process-fault leads to changes in process behavior then the model fitted using ‘normal’
operating condition data won’t be very accurate with faulty data and therefore, the residuals
will show higher values. Consequently, the residuals are monitored for fault detection as
summarized in Figure 5.6.

𝑦̂(𝑘) Residuals 𝜀(𝑘)


Univariate Monitoring
{y(k)} TSA Model (𝑦 − 𝑦̂(𝑘)) Technique

Process Monitoring Model

Figure 5.6: Process monitoring methodology via monitoring of time-series analysis-based


residuals.
91
`

# 1-step ahead predictions for test data


results_test = results.apply(T_test_centered)
T_test_centered_pred = results_test.fittedvalues # same as results_test.predict()
residuals_test = T_test_centered - T_test_centered_pred

The above plots show that the residuals exhibit an increase in the mean value after the onset
of process fault (after sample # 300 for test dataset). The control chart for the whole dataset
makes the sustained unusual values of the residuals more evident. The fault diagnosis
exercise can now be carried out to isolate the root cause of the fault.

Fault detection via monitoring of model parameter estimates


We saw in the above example how process faults lead to change in the
behavior of process variables. Therefore, as alternative to residual
monitoring, another popular approach for process fault detection is to build
new dynamic models for the process at regular intervals and check for
significant changes in model parameters. Significant parameter changes can
be good indicators of process fault.

92
`

Stationarity revisited and introduction to invertibility

In Chapter 4, we had seen how homogeneous non-stationary signals can be made


stationary by differencing. However, it is not always easy to infer homogeneous non-
stationarity from simple time-plots. Fortunately, ACF, PACF, and PSD plots can provide
crucial clues. The characteristic indicators of non-stationary behavior for these graphical
plots are provided below. You should be easily able to explain the rationale behind these
characteristics based on the concepts we have covered so far.

ACF plot PACF plot PSD

Slowly decaying/nearly Near-unity value at lag 1 Significant power at low


constant frequencies

Checking stationarity using noise transfer operator H(q-1)


Transfer operator for the ARMA model in Eq. 6 can be written as

numerator polynomial in q-1


1 + σ𝑟𝑗=1 𝑐𝑗 𝑞 −𝑗 𝐶(𝑞 −1 )
𝐻(𝑞 −1 ) = =
1 + σ𝑝𝑗=1 𝑎𝑗 𝑞 −𝑗 𝐴(𝑞 −1 )
denominator polynomial in q-1

An ARMA model represents a stationary process if the absolute of the roots of 𝐴(𝑞 −1 ) is
greater than 1. For example, for the AR(1) process y(k) = ay(k-1) + e(k),

1
𝐴(𝑞 −1 ) = 1 − 𝑎𝑞 −1 ⇒ 𝑟𝑜𝑜𝑡 =
𝑎
1
⇒ 𝑠𝑡𝑎𝑡𝑖𝑜𝑛𝑎𝑟𝑖𝑡𝑦 𝑖𝑓 ฬ ฬ > 1 ⇒ |𝑎| < 1
𝑎

In SysID literature, roots of 𝐴(𝑞 −1 ) are called poles. Note that if degree of 𝐴(𝑞 −1 ) or the
order of autoregressive part is > 1, then poles can be complex numbers. Therefore, ‘poles
outside the unit circle’ is the correct way of stating the condition of stationarity.

93
`

Poles inside the unit circle lead to explosive non-stationarity and poles on the unit circle
causes homogeneous non-stationarity (such as random walk process). MA processes
have 𝐴(𝑞 −1 ) = 1 and are always stationary (for finite r and cj).

Invertibility
Another condition imposed on disturbance model to represent realistic processes is
invertibility. The condition requires that the roots of the numerator polynomial (𝐶(𝑞 −1 )),
also called zeros of the transfer operator, lie outside the unit circle. AR models have
𝐶(𝑞 −1 ) = 1 and therefore, are always invertible. Without going into mathematical details,
it suffices to know that for non-invertible models, it is possible to write e(k) as a
summation of future values of y(k); such models are called non-causal models and do
not represent realistic processes.

5.6 Autoregressive Integrated Moving Average


(ARIMA) Models: An Introduction

In Chapter 4 we saw that non-stationary signals may be modeled via stationary ARMA models
after suitable differencing. Such difference-stationary processes are formalized as ARIMA
processes43 and are represented as

𝐶(𝑞 −1 ) 1 + σ𝑟𝑗=1 𝑐𝑗 𝑞 −𝑗
(1 − 𝑞 −1 )𝑑 𝑦(𝑘) = 𝑒(𝑘) = 𝑒(𝑘)
𝐴(𝑞 −1 ) 1 + σ𝑝𝑗=1 𝑎𝑗 𝑞 −𝑗
Integrating part
ARMA part
with d differences

𝐶(𝑞−1 )
𝑧(𝑘) = 𝑒(𝑘) where 𝑧(𝑘) = (1 − 𝑞 −1 )𝑑 𝑦(𝑘)
𝐴(𝑞 −1 )
differenced signal

43
Sometimes, modelers include a constant term 𝜃𝑜 in ARIMA model which then takes the following form
𝐶൫𝑞 −1 ൯
(1 − 𝑞 −1 )𝑑 𝑦(𝑘) = 𝜃𝑜 + 𝑒(𝑘). In Chapter 4, we had shown that a deterministic trend of degree d can be removed
𝐴(𝑞 −1 )
with differencing d times. Therefore, the inclusion of 𝜃𝑜 in the model is equivalent to explicitly including a deterministic
trend in the model.
94
`

For example, consider a signal that becomes ARMA(1,1) stationary after first differencing

1 − 𝑐𝑞 −1 transfer operator form


(1 − 𝑞 −1 )𝑦(𝑘) = 𝑒(𝑘)
1 − 𝑎𝑞 −1
⇒(1 − 𝑎𝑞 −1 )( 𝑦(𝑘) − 𝑦(𝑘 − 1)) = 𝑒(𝑘) − 𝑐𝑒(𝑘 − 1)
⇒ 𝑦(𝑘) = (1 + 𝑎)𝑦(𝑘 − 1) − 𝑎𝑦(𝑘 − 2) − 𝑐𝑒(𝑘 − 1) + 𝑒(𝑘) difference equation form

It should have occurred to you by now that q notation makes it much easier to
represent and work with complicated models.

The above model is called ARIMA(p,d,r) due to the dth degree of differencing and ARMA(p,r)
modeling. You can see that with suitable choice of p, d, and r, MA, AR, and ARMA models
become special cases of ARIMA model.

Random walk model


An ARIMA(p,1,r) disturbance model is equivalent to saying that there are
random (and temporally correlated) step changes occurring in the
disturbance signal. A pure integrating model of order 1 (ARIMA(0,1,0), a.k.a.
random walk model) takes the following form

(1 − 𝑞 −1 )𝑦(𝑘) = 𝑒(𝑘) ⇒ 𝑦(𝑘) = 𝑦(𝑘 − 1) + 𝑒(𝑘)

The integrating model is called as such because the noise values are
continuously added to the output signal.

Model order selection


The graphical tools can be used to check if differencing is needed. If the differenced series
shows signs of AR or MA or ARMA, then no further differencing is required. Very rarely, you
would need to choose p, d, or r greater than 2.

Unit-root tests
A rigorous way of checking the presence of unit pole (and therefore the need of differencing)
is unit-root test. To understand this test, consider a simple AR(1) process y(k) = ay(k-1) +
e(k). To warrant differencing, ‘a’ needs to be equal to 1 and therefore, in the regression model
z(k) = (a-1)y(k-1) + e(k) where z(k) = y(k) – y(k-1), the coefficient a-1 would equal 0. The unit-
95
`

root test is simply a hypothesis test on this coefficient being equal to zero. This is called
Dickey-Fuller test.

If you have some experience with hypothesis testing, then you would know that if the p value
of the test is above a specified threshold/significance level44, then the (null) hypothesis (on
the series under study being non-stationary) is not rejected. For more generic series of
integrating order > 1, a more generic augmented Dickey-Fuller test is used. However, the test
process remains the same.

Example 5.4:
Generate data from AR process and perform ADF test to check for unit root.

# import packages
import numpy as np, matplotlib.pyplot as plt
from statsmodels.tsa.arima_process import ArmaProcess

# generate data
ar_coeffs = np.array([1, -0.96]) # y(k) = 0.96y(k-1) + e(k)
ARprocess = ArmaProcess(ar=ar_coeffs)
y = ARprocess.generate_sample(nsample=1000)

# perform augmented Dickey-Fuller test


from statsmodels.tsa.stattools import adfuller
result = adfuller(y)
print('p-value: %f' % result[1])

Since the p-value is less than 0.05, the null hypothesis is


>>> p-value: 0.000187 rejected ⇒ the time series is stationary

𝒚(𝒌) = 𝟎. 𝟓𝒚(𝒌 − 𝟏) + 𝒆(𝒌) 𝒚(𝒌) = 𝟎. 𝟗𝟖𝒚(𝒌 − 𝟏) + 𝒆(𝒌) 𝒚(𝒌) = 𝟎. 𝟗𝟗𝟗𝒚(𝒌 − 𝟏) + 𝒆(𝒌)

p-value: 0 p-value: 0.027 p-value: 0.904

44
The threshold is commonly set to 5% or 0.05
96
`

Example 5.5:
In this example we will utilize a given a time series generated from the following process.
With guidance from the graphical plots and ADF test, we will infer the correct model
orders. Thereafter, an ARIMA model will be fitted to find the model parameters.

1 − 0.7𝑞 −1
(1 − 𝑞 −1 )𝑦(𝑘) = 𝑒(𝑘)
1 − 0.5𝑞 −1
Note that packages like pmdarima exist which can be used to automatically estimate the
order of differencing and the AR/MA orders.

# import packages and read data


import numpy as np, matplotlib.pyplot as plt
from statsmodels.tsa.arima.model import ARIMA
y = np.loadtxt('ARIMA_data.txt') p-value: 0.325

The correlation plots and the ACF PACF


ADF test clearly indicate the
presence of unit-root. Therefore,
we know that differencing is
required atleast once. Let’s
check the ACF and PACF plots
of the difference signal.

p-value: 0

The ADF test indicates that the differenced signal is stationary and therefore no further
differencing is required. Moreover, the ACF and PACF plots clearly indicate the AR
and MA orders to be 1 (both plots show sharp decline in value after lag 1). We can
therefore fit an ARIMA(1,1,1) model to the given data.
# fit ARIMA(1,1,1) model
y_centered = y - np.mean(y)
model = ARIMA(y_centered, order=(1, 1, 1))
results = model.fit()
print(results.summary()) Parameter estimates are close to actual

97
`

5.7 Forecasting Signals using ARIMA

Previously we saw how time series models can be used to build process monitoring solutions.
As alluded to before, another common use of such models is in forecasting of stochastic
signals. Although the Statsmodels package provides native support for generating forecasts,
it would be instructive to see what the forecasting work process actually entails. We will use
a simple ARIMA(1,1,1) model for this illustration. Let the model be the following

1 − 0.7𝑞 −1
(1 − 𝑞 −1 )𝑦(𝑘) = 𝑒(𝑘)
1 − 0.5𝑞 −1

Let’s expand the above into a difference equation with only y(k) on the L.H.S.

𝑦(𝑘) = 1.5𝑦(𝑘 − 1) − 0.5𝑦(𝑘 − 2) − 0.7𝑒(𝑘 − 1) + 𝑒(𝑘) eq. 7

To derive the expression for the forecasts from Eq. 7, the following notation/rules apply:

• 𝑦̂(𝑘 + 𝑙|𝑘) ≡ 𝑦̂(𝑙) denotes the lth step-ahead forecast/prediction using all information
available at time k
• Any y on R.H.S. of Eq. 7 that has not yet occurred is replaced with its forecast 𝑦
• Any future noise term is replaced with zero and past noise term with the 1-step ahead
residuals (for example, 𝑒(𝑘 − 1) = 𝑦(𝑘 − 1) − 𝑦̂(𝑘 − 1|𝑘 − 2))

Let’s see how the forecast expressions look like for 𝑙 = 1, 2, 3, …

𝑦̂(1) = 1.5𝑦(𝑘) − 0.5𝑦(𝑘 − 1) − 0.7𝑒(𝑘) to be replaced with


𝑦(𝑘) − 𝑦̂(𝑘|𝑘 − 1)
𝑦̂(2) = 1.5𝑦̂(1) − 0.5𝑦(𝑘)
𝑦̂(3) = 1.5𝑦̂(2) − 0.5𝑦̂(1) both error terms in Eq. 7
⋮ replaced with zero

A somewhat incomplete aspect in the above forecast expressions is computation of e(k). The
annotation text suggests making use of 𝑦̂(𝑘|𝑘 − 1), but it would involve the term e(k-1). This
leads to a recursive approach to find the past noise values. The established approach is to
start from time p + d, set estimated noise values for times ≤ p + d to zero and then recursively
estimate the noise values until time k using the forecast expression for the 1-step ahead
forecast. For our ARIMA(1,1,1) model, the computation would look like the following:

98
`

(approximation) 0 0 (replacement with conditional mean)


𝑦̂(2|1) = 1.5𝑦(1) − 0.5𝑦(0) − 0.7𝑒(1) + 𝑒(2)

𝑒(2) = 𝑦(2) − 𝑦̂(2)

0
𝑦̂(3|2) = 1.5𝑦(2) − 0.5𝑦(1) − 0.7𝑒(2) + 𝑒(3)

𝑒(3) = 𝑦(3) − 𝑦̂(3)


This completes our quick overview of time-series analysis and its applications. Hopefully, you
have gained an in-depth understanding of the concepts behind time-series analysis and can
appreciate its usefulness in describing process systems.

Summary

In this chapter we looked at the four common models used to describe time series, namely,
AR, MA, ARMA, and ARIMA models. We studied their model forms and procedures behind
the corresponding model order selection. We looked at how ACF and PACF tools provide
useful clues regarding model structure. We also looked into more details the stationarity
requirements of TSA models and ways of assessing stationarity of signals. We will build upon
the concepts covered in this chapter and look at models used to describe input-output
dynamic signals in the next chapter.

99
`

Chapter 6
Input-Output Modeling - Part 1:
Simple Yet Popular Classical Linear Models

T
here is beauty is simplicity - this age-old truth perfectly sums up the reason behind the
popularity of two simple input-output models, FIR and ARX models, that we will learn
about in this chapter. In the age of artificial neural networks, these models still hold on
their own and are an essential part of any PDS’s toolkit. As alluded to before, I/O processes
have inputs signals that can be manipulated to control the output signals. The objective,
therefore, of I/O modeling is to find the deterministic relationship between the input and output
signals, and, optionally, find a suitable model for the stochastic disturbances affecting the
outputs.

FIR model is a non-parametric model and is used in thousands of MPC solutions in process
industry globally. The remarkable success of the FIR-based MPCs is testament to the fact
that simple models can be quite useful representation of complex industrial processes. FIR
models are intuitive and simple enough to be understood by plant operators. However, nothing
is all rosy with anything. FIR models, owing to their flexibility often lead to overfitting. ARX
models, on the other hand, are parametric models and require much lower number of
parameters. Consequently, the resulting models are ‘smoother’. ARX models are often the
initial choice in any SysID exercise. Nonetheless, ARX models can easily suffer from high
bias errors. Since these two models are so critical, this chapter is devoted to understanding
their various aspects, along with their pros and cons, in detail.

Specifically, the following are covered in the chapter.


• Introduction to FIR and ARX models
• SysID of industrial furnaces using FIR and ARX models
• Hyperparameter selection for FIR and ARX models
• Stochastic component of ARX models
• Model bias in FIR and ARX models

100
`

6.1 FIR Models: An Introduction

Impulse response of a system is its response to a special impulse input as shown in Figure
6.1. The impulse response model approximates the system output as a linear combination of
several impulse responses due to past inputs. Since the impulse responses usually decay to
zero, it suffices to include only the past few values (say M) of u(k) to approximate y(k). The
value ‘M’ is called the model order and the resulting model is called the finite impulse response
(FIR) model. You will notice that there is no attempt to model stochastic disturbances and a
non-parametric modeling form (there is no compact mathematical structure) is adopted.
Consequently, FIR model is among the simplest SysID model.
Unit Impulse Input

𝑢(𝑘) = 1 𝑓𝑜𝑟 𝑘 = 0 𝑔3 𝑔4 𝑦(𝑘) ≈ 𝑔𝑘


= 0, 𝑜𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒 𝑔2 𝑔5
1 𝑔1 𝑔6 Impulse response
y(k) 𝑔7 coefficients

𝑦(𝑘) ≈ σ∞
𝑖=1 𝑔𝑖 𝑢(𝑘 − 𝑖) IIR (Infinite impulse response)
each of these can be treated as
impulse inputs of magnitudes u(k)

𝑦(𝑘) ≈ σ𝑀
𝑖=1 𝑔𝑖 𝑢(𝑘 − 𝑖)
Generic Input

y(k) FIR (Finite impulse


response)

k
Figure 6.1: Impulse response model for a SISO system

Fitting a FIR model entails estimation of the impulse response coefficients. Although a FIR
model’s structure is quite simple, it is very flexible and given sufficiently large M, any type of
complex impulse response can be fitted. It is common to employ model orders of 90 to 120 to
get all the impulse coefficients. However, such large parameters dimensionality often leads to
overfitting (impulse response curves show wiggles or spikes due to output signal corruption
by process disturbances). Apart from model flexibility, another advantage of FIR model is that
an estimate of I/O delay is automatically obtained after model fitting. For a system with delay
d, the first d impulse coefficients will be zero or close to zero. This is in fact a classical method
for delay estimation. FIR models also provide unbiased parameter estimates as the
deterministic part of the model is independently parametrized (recall our discussion from
Chapter 4). These favorable properties of FIR models make them the dominant SysID model
deployed in industrial MPCs45.

45
Darby and Nikolaou, MPC: Current practice and challenges. Control Engineering Practice, 2012
101
`

Step-response curves

Step response is response of a system to a step change in its input as shown below

𝑢(𝑘) = 1 𝑓𝑜𝑟 𝑘 ≥ 0 𝑠4 𝑠5 𝑠6
Unit Step Input

1 = 0 𝑓𝑜𝑟 𝑘 < 0 𝑠3
⋯ Step response
⋯ curve
𝑠1 𝑠2

As should be apparent, a step response curve can provide a quick assessment of


process delay, time-constant of the process, and steady-state gain. System nonlinearity
can also be quickly assessed by looking at response curves to steps of different
magnitudes. Due to these favorable properties and the ease of inducing step inputs
(compared to impulse inputs), step response curves are popularly used to visualize a
system’s behavior in process industry.

The step response coefficient, s(k), can be easily estimated from the impulse
coefficients as follows
𝑘

𝑠(𝑘) = ෍ 𝑔(𝑗)
𝑗=1

Model estimation

An FIR model46 can be conveniently estimated using least squares method. Consider an FIR
model of order M and the following data sequence

𝑦(0), 𝑦(1), … , 𝑦(𝑁 − 1)


Available historical SISO process data
𝑢(0), 𝑢(1), … , 𝑢(𝑁 − 1)

46
A FIR model can compactly be written as 𝑦(𝑘) = 𝜑𝑘𝑇 𝜃0 + 𝑣(𝑘) where 𝜑𝑘 is regressor vector (ሾ𝑢(𝑘 − 1), 𝑢(𝑘 −
2), … , 𝑢(𝑘 − 𝑀)ሿ𝑇 ), 𝜃0 is parameter vector (ሾ𝑔(1), 𝑔(2), … , 𝑔(𝑀)ሿ𝑇 ), and 𝑣(𝑘) is disturbance signal which is ignored
during estimation of 𝜃0 . Note that 𝑣(𝑘) is not restricted to be white noise.
102
`

With 𝑒(𝑘) = 𝑦(𝑘) − σ𝑀


𝑖=1 𝑔(𝑖)𝑢(𝑘 − 𝑖) as equation error, the data can be put in the following
matrix form

𝑦(𝑀) 𝑢(𝑀 − 1) 𝑢(𝑀 − 2) ⋯ 𝑢(0) 𝑔1 𝑒(𝑀)


‫ۍ‬ ‫ې‬ ‫ۍ‬ ‫ې‬ ‫ې ۍ‬ ‫ۍ‬ ‫ې‬
‫ 𝑀(𝑦ێ‬+ 1)‫ۑ‬ ‫)𝑀(𝑢 ێ‬ 𝑢(𝑀 − 1) ⋯ 𝑢(1) ‫ۑ‬ ‫𝑔 ێ‬2 ‫ۑ‬ ‫ 𝑀(𝑒ێ‬+ 1)‫ۑ‬
‫ێ‬ ‫=ۑ‬ ‫ێ‬ ‫ۑ‬ ‫ۑ ⋮ ێ‬+ ‫ێ‬ ‫ۑ‬
‫ێ‬ ⋮ ‫ۑ‬ ‫ێ‬ ⋮ ⋱ ⋯ ⋮ ‫ۑ‬ ‫ێ‬ ⋮ ‫ۑ‬
‫ێ‬ ‫ۑ‬ ‫ێ‬ ‫ۑ‬ ‫ۑ ێ‬ ‫ێ‬ ‫ۑ‬
‫ 𝑁(𝑦 ۏ‬− 1)‫ے‬ ‫ 𝑁(𝑢 ۏ‬− 2) ⋯ ⋯ 𝑢(𝑁 − 1 − 𝑀)‫ے‬ ‫ے 𝑀𝑔ۏ‬ ‫ 𝑁(𝑒 ۏ‬− 1)‫ے‬

𝑌 = Ф𝜃 + 𝐸

Estimate of the parameter vector, 𝜃෠, is obtained by minimizing the error vector. You probably
would already know that an analytical solution for 𝜃෠ exists and is given as 𝜃෠ = ሾФ𝑇 Фሿ−1 Ф𝑇 𝑌.

Model order selection

Correct order selection is important in FIR modeling. Too low model order won’t catch complex
process dynamics and lead to inaccurate process gain estimates, and too high model order
can lead to overfitting resulting in noisy impulse/step response curves. If any approximate
prior knowledge is available about the process settling time or the time to steady state (TTSS),
then it can be used to set the model order. For example, if TTSS is 120 then as many
coefficients would be required in the model.

Example 6.1:
File FIR_illustrate.csv contains I/O data for the below process whose shown step
response suggests a TTSS of ~30. The variance of the noise signal was adjusted to
provide signal-to-noise ratio of 20. We will fit three FIR models with model orders 3, 30,
and 60, respectively, and compare their step responses with the true curve.

2𝑞 −2
𝑦(𝑘) = 𝑢(𝑘) + 𝑣(𝑘)
1 − 1.1𝑞 −1 + 0.8𝑞−2

1
𝑣(𝑘) = 𝑒(𝑘)
1 − 0.6𝑞−1

An AR signal as disturbance

103
`

We will use the SIPPY package to fit our FIR models and employ Control package
(https://pypi.org/project/control/) to generate step responses. Let’s start with loading the data

# import packages
import matplotlib.pyplot as plt, numpy as np
from sklearn.preprocessing import StandardScaler
from sippy import system_identification as SysID
import control

# read data
data = np.loadtxt('FIR_illustrate.csv', delimiter=',')
u = data[:,0, None]; y = data[:,1, None]

# center data before model fitting


u_scaler = StandardScaler(with_std=False)
u_centered = u_scaler.fit_transform(u)

y_scaler = StandardScaler(with_std=False)
y_centered = y_scaler.fit_transform(y)

# fit FIR model


model_order = 30 Time delay
FIRmodel = system_ SysID (y_centered, u_centered, 'FIR', FIR_orders=[model_order,0])

Duration of step response


# generate step response of FIR model
step_response_model, _ = control.matlab.step(FIRmodel.G, T=60)
plt.plot(step_response_model, 'm--', linewidth=0.8)
plt.ylabel('step_response_model'), plt.xlabel('k')

The plots below show the obtained step responses (along with the true step response)
for the three different choices of the model order. [The reader can check out the code
provided in the online repository to see how the true step response is generated.]

• Under-fitted • Seemingly the right fit • Over-fitted


• Oscillations not captured • Oscillatory nature captured • Noisy response curve
• Gain estimate slightly off due to
noise and limited training data

104
`

6.2 FIR Modeling of Industrial Furnaces

To showcase an industrial application of FIR models, we will consider fired heaters used in
petroleum refineries wherein, as shown in the figure below, fuel is combusted to heat feed oil
and vaporize it for subsequent fractionation47. In the SISO version of the system, we will
consider the task of keeping the outlet temperature of the heated oil (TO) in control. Changes
in feed oil temperature, TI, or the feed flow will impact TO. The controller adjusts the flow of
the fuel gas (although indirectly, by manipulating the set-point of the flue-gas PID controller.
The PID controller, not shown in the schematic, adjusts the fuel-gas stream’s valve opening
to meet the specified flow)48. The process controller, however, needs a model to understand
the relationship between flue gas flow set-point (FGSP) and TO.

To obtain the model, we will use data provided in the file IndustrialFiredHeater_SISO.csv
which contains 1000 samples of TO and FGSP obtained from an open-loop simulation of the
system wherein FGSP was excited using a GBN signal and the system was subjected to
disturbances in TI.49 Note that the time interval here is in minutes and not seconds.

Figure 6.2: Representative schematic of a fired heater used in petroleum refineries

47
The reader is referred to https://apmonitor.com/dde/index.php/Main/FiredHeaterSimulation for more details on the
system. At this link, readers can also find the system model that is used to generate the simulation dataset used in this
case-study.
48
Using PID controller’s setpoints as manipulated variables is a very standard approach in modern (MPC) controllers.
49
Online code repository shows how the identification test data was generated
105
`

Let’s start by importing the required packages and exploring the provided I/O dataset.

# import packages
import matplotlib.pyplot as plt, numpy as np, control
from sklearn.preprocessing import StandardScaler
from sippy import system_identification as SysID
from statsmodels.tsa.stattools import ccf

# read fired heater identification test data and plot


data = np.loadtxt('IndustrialFiredHeater_SISO.csv', delimiter=',')
FG, TO = data[:,0, None], data[:,1, None]

plt.figure(), plt.plot(FG, 'steelblue'), plt.ylabel('u(k)'), plt.xlabel('k')


plt.figure(), plt.plot(TO, 'g'), plt.ylabel('y(k)'), plt.xlabel('k')

Next, we will center the data and fit an FIR model using AIC for model order selection.

# center data and fit FIR model


u_scaler = StandardScaler(with_std=False)
FG_centered = u_scaler.fit_transform(FG)

y_scaler = StandardScaler(with_std=False)
TO_centered = y_scaler.fit_transform(TO)

FIRmodel = SysID(TO_centered, FG_centered, 'FIR', IC='AIC', nb_ord=[1,20])


# a range of 1 to 20 is specified for optimal order search

>>> suggested orders are: Na= 0 ; Nb= 11 Delay: 0

As shown, an FIR model with eleven coefficients has been found to provide the optimal fit.
With the model fitted, we will conduct the model quality checks, starting with residual analysis.
106
`

# get model predictions and residuals on training dataset


TO_predicted_centered = FIRmodel.Yid
# Yid attribute provides the output of the identified model during model ID
TO_predicted = np.transpose(y_scaler.inverse_transform(TO_predicted_centered))
residuals = TO - TO_predicted

plt.figure(), plt.plot(TO, 'g', label='Measurements')


plt.plot(TO_predicted, 'r', label='Predictions')
plt.title('Training data'), plt.ylabel('y(k): Measured vs predicted'), plt.xlabel('k'), plt.legend()

Note that we will not perform any autocorrelation check on the above residuals because FIR
model’s residuals are not constrained to be white noise. However, cross-correlations between
the residual and the input sequences need to be checked.

# CCF b/w residual and input sequences


ccf_vals = ccf(residuals, FG, adjusted=False) # ccf for lag >= 0
ccf_vals = ccf_vals[:21] # ccf for lag 0 to 20

lags, conf_int = np.arange(0,21), 1.96/np.sqrt(len(residuals))


plt.figure(), plt.vlines(lags, [0], ccf_vals), plt.axhline(0, 0, lags[-1])
plt.plot(lags, ccf_vals, marker='o', linestyle='None')
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue') # shaded confidence interval

Cross-correlation
coefficients are within
the confidence interval

107
`

Next, we will check if the fitted model has any unexpected characteristics; for this we will
generate the model’s step response curve and compare with the true process curve.

# generate step response of FIR model


step_response_model, _ = control.matlab.step(FIRmodel.G, T=21)

# generate step response of original process


s = control.matlab.tf('s')
sys_G = 6/(3*s**2 + 4*s + 1) # https://apmonitor.com/dde/index.php/Main/FiredHeaterSimulation
step_response_process, T = control.matlab.step(sys_G, T=20)

# overlay the step responses


plt.figure(), plt.plot(step_response_model, 'm--', label="FIR model")
plt.plot(T, step_response_process, 'c', label="Actual process")
plt.ylabel('Step responses'), plt.xlabel('k'), plt.legend()

Curves compare well; no


unexpected characteristics in
the model’s curve

In practice, you will often not be so lucky as to have access to the true process step response
curve. Nonetheless, you will probably have some process insights to judge if the model’s step
response curve is reasonable. Overall, our model seems good to be accepted. Note that we
did not perform any simulation checks here because for an FIR model, simulation equals
predictions. We will perform simulation checks for the ARX model later in this chapter.

108
`

6.3 ARX Models: An Introduction

ARX (autoregressive with eXogenous input) model is extension of AR time series model to
I/O systems. Here, as shown in Figure 6.3, the current output state is written as a linear
combination of past inputs as well as past output measurements50. The FIR model may be
seen as a special case of ARX model with 𝑛𝑎 = 0. However, the inclusion of past
measurements in the ARX model allows for more compact description of the process and
helps to overcome the high parameter-dimensionality issue faced by FIR model. The price for
parsimonious representation is paid for by having to specify more hyperparameters (𝑑, 𝑛𝑎 , 𝑛𝑏 ).

ARX difference equation form ARX model using q notation


𝑛𝑎 𝑛𝑏
𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) − 𝑎2 𝑦(𝑘 − 2) ⋯ − 𝑎𝑛𝑎 𝑦(𝑘 − 𝑛𝑎 )
−1 −𝑑
+ 𝑏1 𝑢(𝑘 − 𝑑 − 1) + ⋯ + 𝑏𝑛𝑏 𝑢(𝑘 − 𝑑 − 𝑛𝑏 ) ቌ1 + ෍ 𝑎𝑗 𝑞 ቍ 𝑦(𝑘) = 𝑞 ቌ෍ 𝑏𝑗 𝑞 −1 ቍ 𝑢(𝑘) + 𝑒(𝑘)
𝑗=1 𝑗=1
+ 𝑒(𝑘)
⇒ 𝐴(𝑞 −1 ) 𝑦(𝑘) = 𝑞 −𝑑 𝐵(𝑞 −1 ) 𝑢(𝑘) + 𝑒(𝑘)

ARX block diagram ARX transfer operator form


e(k) 𝑞 −𝑑 𝐵(𝑞 −1 ) 1
𝑦(𝑘) = −1
𝑢(𝑘) + 𝑒(𝑘)
1 𝐴(𝑞 ) 𝐴(𝑞 −1 )
u(k) y(k)
𝑞 −𝑑 𝐵(𝑞 −1 )
𝐴(𝑞 −1 ) = 𝐺(𝑞 −1 )𝑢(𝑘) + 𝐻(𝑞 −1 )𝑒(𝑘)

Figure 6.3: ARX model structure in different forms

A salient (and often overlooked) feature of ARX model is the implicit assumption that the noise
1
enters the system at such a point that it is subjected to the same process dynamics (𝐴(𝑞−1 ))
as the deterministic signal u(k). The block diagram in Figure 6.3 emphasizes this aspect. In
real world, an example scenario could be perturbations affecting the process feed which then
passes through the entire process dynamics. Not many systems that you will encounter will
show such noise characteristics. Moreover, the dependent parametrization of G and H
operators imply that an ARX model is biased for incorrect noise model specification even if
you choose your model orders for the deterministic part correctly. Despite the shortcomings,
the convenience of estimating ARX models often makes them the first choice for an initial
solution in any SysID exercise.

50
We have not included the term u(k) in the difference equation forms of FIR and ARX models. This is because we are
working with discrete-time models and any changes in u(k) most often does not have instantaneous impact on y(k).
109
`

Model estimation

Least squares method can again be employed here. For illustration, let’s consider a 2 nd order
ARX51 model with delay = 1: 𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) − 𝑎2 𝑦(𝑘 − 2) + 𝑏1 𝑢(𝑘 − 2) + 𝑏2 𝑢(𝑘 − 3) +
𝑒(𝑘). Let 𝜑𝑘 = ሾ−𝑦(𝑘 − 1), −𝑦(𝑘 − 2), 𝑢(𝑘 − 2), 𝑢(𝑘 − 3)ሿ𝑇 be the regressor vector and 𝜃0 =
ሾ𝑎1 , 𝑎2 , 𝑏1 , 𝑏2 ሿ𝑇 be the parameter vector. Therefore, 𝑦(𝑘) = 𝜑𝑘𝑇 𝜃0 + 𝑒(𝑘) and the matrix form
would look as follows

𝑦(3) −𝑦(2) −𝑦(1) 𝑢(1) 𝑢(0) 𝑎1 𝑒(3)


‫ۍ‬ ‫ې‬ ‫ۍ‬ ‫ې‬ ‫ې ۍ‬ ‫ۍ‬ ‫ې‬
‫(𝑦 ێ‬4) ‫ۑ‬ ‫ ێ‬−𝑦(3) −𝑦(2) 𝑢(2) 𝑢(1) ‫ۑ‬ ‫ 𝑎ێ‬2 ‫ۑ‬ ‫(𝑒 ێ‬4) ‫ۑ‬
‫ێ‬ ‫=ۑ‬ ‫ێ‬ ‫ۑ‬ ‫ۑ ⋮ ێ‬+ ‫ێ‬ ‫ۑ‬
‫ێ‬ ⋮ ‫ۑ‬ ‫ێ‬ ⋮ ⋱ ⋯ ⋮ ‫ۑ‬ ‫ێ‬ ⋮ ‫ۑ‬
‫ێ‬ ‫ۑ‬ ‫ێ‬ ‫ۑ‬ ‫ۑ ێ‬ ‫ێ‬ ‫ۑ‬
‫ 𝑁(𝑦ۏ‬− 1)‫ے‬ ‫ۏ‬−𝑦(𝑁 − 2) ⋯ ⋯ 𝑢(𝑁 − 4)‫ے‬ ‫𝑏ۏ‬2 ‫ے‬ ‫ 𝑁(𝑒ۏ‬− 1)‫ے‬

𝑌 = Ф𝜃 + 𝐸

The analytical solution, 𝜃෠ = ሾФ𝑇 Фሿ−1 Ф𝑇 𝑌, exists if the matrix Ф𝑻 Ф is invertible which is
guaranteed if the input signal u(k) is persistent exciting of sufficient order.

Model bias in ARX and FIR models


We have noted that the ARX model’s assumption on noise signal is pretty
𝑒(𝑘)
restrictive. If the actual process has a stochastic part different from ,
𝐴(𝑞 −1 )
then 𝜃෠ estimated via least squares will be biased52 even if G(q-1)’s structure
is correct because G(q-1) and H(q-1) are not independently parameterized.

We can look at this aspect from another perspective: one of the requirements
in least squares method for bias-free estimates is that the equation error is
uncorrelated with the regressor vector. Now let’s consider an example
scenario where the actual process is given by 𝑦(𝑘) = −𝑎10 𝑦(𝑘 − 1) +
𝑏10 𝑢(𝑘 − 1) + 𝑒(𝑘) + 𝑐10 𝑒(𝑘 − 1) and the fitted model is 1st order ARX model
𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) + 𝑏1 𝑢(𝑘 − 1). Since the equation error 𝜖(𝑘) equals 𝑒(𝑘) +
𝑐10 𝑒(𝑘 − 1), it becomes correlated to the regressor vector as y(k-1) is

51
An ARX model requires specification of two orders: order of the numerator (𝐵(𝑞 −1 )) and denominator (𝐴(𝑞 −1 ))
polynomials. Specification of only a single order value usually implies 𝑛𝑎 = 𝑛𝑏 .
52
A simple way to understand bias is that if multiple estimates of a parameter is obtained from different sets of I/O data,
then the difference between the average of the estimates and the true parameter value is the bias.
110
`

correlated to e(k-1). Correspondingly, parameter estimates are biased53. The


amount of bias in parameter estimates depend on the level of noise. For high
SNR, the bias can be negligible.

In FIR model, H(q-1) is not modeled and therefore, FIR model’s least-squares
estimates are unbiased. Note that these discussions assume that the
disturbance signal is not correlated to input which is true for open-loop
processes.

Example 6.2:
In this example we will study the impact of SNR on ARX model bias. We will assume the
following true process
0.7𝑞−1 1
𝑦(𝑘) = −1
𝑢(𝑘) + 𝑒(𝑘)
1 − 0.7𝑞 1 − 0.2𝑞−1

We will use SNRs of 10 and 100. The data files ARX_illustrate_SNR10.csv and
ARX_illustrate_SNR100.csv contain I/O data with 1000 samples each. We will fit 1 st
order ARX models using least squares and compare the model’s step responses and
estimated parameters with those from the true process.

# import packages
import matplotlib.pyplot as plt, numpy as np
from sklearn.preprocessing import StandardScaler
from sippy import system_identification as SysID
import control

# read data
data = np.loadtxt('ARX_illustrate_SNR10.csv', delimiter=',')
u = data[:,0, None]; y = data[:,1, None]

# center data before model fitting


u_scaler = StandardScaler(with_std=False); u_centered = u_scaler.fit_transform(u)
y_scaler = StandardScaler(with_std=False); y_centered = y_scaler.fit_transform(y)

# fit ARX model 0.92𝑞−1


𝐺(𝑞 −1 ) =
ARXmodel = SysID(y_centered, u_centered, 'ARX', ARX_orders=[1,1,0]) 1 − 0.56𝑞−1
print(ARXmodel.G) # shows the transfer operator G (in terms of q); Note that
symbol z is used instead of q in the package

53
Alternatives to least squares method such as instrumental variable (IV) method exist which can provide bias-free
estimates for ARX model. However, expectedly, these alternative methods are computationally more involved.
111
`

We can see that with significant level of disturbance, the parameter estimates are not very
accurate. Let’s see how the model’s step response compares against that of the true process.

# generate step response of ARX model


step_response_model, _ = control.matlab.step(ARXmodel.G, T=30)

# generate step response of original process


NUM_G, DEN_G = [0.7], [1, -0.7]
sys_G = control.matlab.tf(NUM_G, DEN_G, 1)
step_response_process, _ = control.matlab.step(sys_G, T=30)

# overlay the step responses


plt.plot(step_response_model, 'm--', linewidth=0.8, label="ARX model")
plt.plot(step_response_process, 'c', linewidth=0.8, label="Actual process")
plt.ylabel('Step responses'), plt.xlabel('k'), plt.legend()

Plots below shows the step response curves and the estimated parameters. As expected,
for SNR=10, the estimated step response curve is farther away from the true curve
compared to those from SNR=100 dataset. However, high noise level is not solely
responsible for this inaccuracy. Incorrect noise model contributes significantly as well. To
illustrate this fact, the plots show curves from an OE model (it is covered in the next
chapter, but it suffices to know that an OE model uses similar structure for operator G as
an ARX model but ignores H) as well. Theoretically, OE model provides unbiased
estimated and therefore its curves are much closer to the true curves.

𝐺𝐴𝑅𝑋 𝐺𝐴𝑅𝑋
0.92𝑞−1 0.72𝑞−1
SNR = 10 = SNR = 100 =
1 − 0.56𝑞−1 1 − 0.68𝑞−1

To further clarify the bias aspect, 500 different sets of I/O data was generated for
SNR=10 and least squares estimation method was used. The histograms below show
the distribution of the parameters. The systematic bias is evident in the plots.

Histogram of 𝑎̂1 Histogram of 𝑏෠1

True value
<-------------- bias ------------> <------------ bias ---------->
Mean of estimates

𝑎̂1 𝑏෠1

112
`

Unbiased high-order ARX modeling

In SysID literature, you may encounter statements stating that high-order ARX models
are unbiased. To understand this, let’s consider an example where the true process is
given by

𝐵(𝑞 −1 ) 𝑒(𝑘)
𝑦(𝑘) = −1
𝑢(𝑘) +
𝐴(𝑞 ) 𝐴(𝑞 )𝐷(𝑞 −1 )
−1

𝐵 𝑒 𝐵𝐷 𝑒
Now instead of fitting an ARX model 𝑦 = 𝑢 + , we can fit the model 𝑦 = 𝑢+ [q-1
𝐴 𝐴 𝐴𝐷 𝐴𝐷
and k not explicitly specified for brevity]. Therefore, if the degree of 𝐷(𝑞 −1 ) is r then we
are basically fitting an ARX model with orders na+r and nb+r instead of an ARX model
with orders na and nb. The higher order ARX model will be unbiased because both G and
H operators are correctly specified! Furthermore, your model residuals will be white now.
𝐵 𝐵𝐷
One can recover the true transfer operator 𝐴 from the estimated transfer operator 𝐴𝐷.

It has been shown that a sufficiently high-order ARX model can approximate any linear
system arbitrarily well. Model order reduction techniques exist to subsequently reduce
the order of the estimated ARX model to make it more tractable.

Hyperparameter selection

Complete specification of an ARX model structure requires values of the input-output delay
(d) and the orders (na and nb which are the number of poles and zeros of the input transfer
operator G). The most common way of estimating these values is to select a range of potential
values for d, na, and nb, and use information criteria such as AIC or cross-validation to find the
most optimal combination. SIPPY implements the AIC-based methodology. As a thumb-rule,
for industrial plants, na is usually three or less.

Approaches alternative to the above brute-force approach exist as well. For example, you can
first build an FIR model to get an estimate of the delay, or a CCF plot between u(k) and y(k)
can be utilized. A process delay of d will imply that the CCF possesses its first significant peak
at lag 𝑑 + 1, while the coefficients will be close to zero for lag ≤ 𝑑. With the delay estimate in
hand, you may then proceed for order estimation via brute-force. Here again, an approximate
order value may be obtained using the Hankel Singular values obtained via subspace
identification procedure (you will learn about this in Chapter 8). This approximate value can
help you decide the potential range for na (and nb) in your brute-force search.

113
`

Once your model has been fitted, model diagnostics may provide you clues regarding
misspecification of the model structure. For example, isolated significant peaks in CCF plot
between u(k) and 𝜖(𝑘) indicate missing input terms in the model. Too small delay specification
will lead to insignificant parameter estimates of the first few input term coefficients. Too large
value of d will show up as several contiguous CCF coefficients (u(k) and 𝜖(𝑘)) outside the
confidence bounds.

Let’s put these guidelines into practice in a realistic case-study presented next.

6.4 ARX Modeling of Industrial Furnaces

Previously, we built a parametric FIR model using the fired-heater dataset; the model ended
up with 11 parameters. In this section, we will attempt to build a parametric ARX model and
see if it ends up providing a more parsimonious description of the system. An ARX model can
be fitted as easy as it was for fitting an FIR model using SIPPY as shown below

# fit ARX model with centered signals


ARXmodel = SysID(TO_centered, FG_centered, 'ARX', IC='AIC', na_ord=[1,20], nb_ord=[1,20], delays=[0,5])

>>> suggested orders are: Na= 4 ; Nb= 3 Delay: 0

The fitted model ends up with 7 parameters and the following structure

0.8405𝑞3 − 0.1983𝑞2 + 0.1147𝑞


𝐺𝐴𝑅𝑋 =
𝑞 4 − 1.541𝑞3 + 0.9914𝑞2 − 0.4023𝑞 + 0.0877

0.8405𝑞−1 − 0.1983𝑞−2 + 0.1147𝑞−3


=
1 − 1.541𝑞−1 + 0.9914𝑞−2 − 0.4023𝑞−3 + 0.0877𝑞−4

Let’s see if this parsimonious model provides as good performance as the FIR model and
passes the diagnostic checks. As before, we start with residual analysis.

# get model predictions and residuals on training dataset


TO_predicted_centered = ARXmodel.Yid
TO_predicted = np.transpose(y_scaler.inverse_transform(TO_predicted_centered))
residuals = TO - TO_predicted

114
`

plt.figure(), plt.plot(TO, 'g', label='Measurements')


plt.plot(TO_predicted, 'r', label='Predictions')
plt.title('Training data'), plt.ylabel('y(k): Measured vs predicted'), plt.xlabel('k'), plt.legend()

The model predictions on the training dataset seems to be almost perfect. However, we know
that 1-step ahead predictions on training dataset can be misleading and therefore, we will
hold onto our judgement for a bit. Let’s look at the ACF and CCF plots of the residuals.

# ACF of residuals
from statsmodels.graphics.tsaplots import plot_acf
conf_int = 1.96/np.sqrt(len(residuals))
plt.figure(), plot_acf(residuals, lags= 20, alpha=None, title='')
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue') # shaded confidence interval

# CCF b/w residual and input sequences


ccf_vals = ccf(residuals, FG, adjusted=False) # ccf for lag >= 0
ccf_vals = ccf_vals[:21] # ccf for lag 0 to 20

lags = np.arange(0,21)
plt.figure(), plt.vlines(lags, [0], ccf_vals), plt.axhline(0, 0, lags[-1])
plt.plot(lags, ccf_vals, marker='o', linestyle='None')
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue') # shaded confidence interval

Coefficients of
interest are within the
confidence intervals

115
`

Next, let’s see the model’s step response curve (and compare with the true process curve).

# generate step response of ARX model


step_response_model, _ = control.matlab.step(ARXmodel.G, T=21)

# generate step response of original process


s = control.matlab.tf('s')
sys_G = 6/(3*s**2 + 4*s + 1)
step_response_process, T = control.matlab.step(sys_G, T=20)

# overlay the step responses


plt.figure(), plt.plot(step_response_model, 'm--', label="ARX model")
plt.plot(T, step_response_process, 'c', label="Actual process")
plt.ylabel('Step responses'), plt.xlabel('k'), plt.legend()

Curves compare well; no


unexpected characteristics in
the model’s curve

The model has done reasonably well so far. We will do one last check and analyze the model’s
m-step ahead responses and simulation responses on a separate validation dataset.

# read fired heater validation data and center


data_val = np.loadtxt('IndustrialFiredHeater_SISO_Validation.csv', delimiter=',')
FG_val, TO_val = data_val[:,0, None], data_val[:,1, None]
FG_val_centered, TO_val_centered = u_scaler.fit_transform(FG_val), y_scaler.fit_transform(TO_val)

# get model's 1-step ahead and 5-step ahead predictions, and simulation responses
from sippy import functionset as fset

TO_val_predicted_1step_centered = np.transpose(fset.validation(ARXmodel, FG_val_centered,


TO_val_centered, np.linspace(0,299,300), k=1))
TO_val_predicted_5step_centered = np.transpose(fset.validation(ARXmodel, FG_val_centered,
TO_val_centered, np.linspace(0,299,300), k=5))
TO_val_simulated_centered, _, _ = control.matlab.lsim(ARXmodel.G, FG_val_centered[:,0],
np.linspace(0,299,300))

116
`

TO_val_predicted_1step = y_scaler.inverse_transform(TO_val_predicted_1step_centered)
TO_val_predicted_5step = y_scaler.inverse_transform(TO_val_predicted_5step_centered)
TO_val_simulated = y_scaler.inverse_transform(TO_val_simulated_centered)

plt.figure()
plt.plot(TO_val, 'g’, label='Measurements')
plt.plot(TO_val_predicted_1step, 'r', label='1-step ahead predictions')
plt.plot(TO_val_predicted_5step, 'c', label='5-step ahead predictions')
plt.plot(TO_val_simulated, 'm', label='Simulation response')
plt.title('Validation data'), plt.ylabel('y(k): Measured vs predicted/simulated'), plt.xlabel('k')
plt.legend()

The plot above again corroborates the adequacy of the model. The 5-step ahead predictions
and the simulated responses seem to have captured the systematic variations in the
temperature signal which suggests that the deterministic component of the model has been
accurately modeled.

117
`

6.5 FIR and ARX MIMO Models

While we have used SISO systems to illustrate the concepts, in industrial practice, you are
more likely to deal with MISO (multi-input single output) systems where, as the name
suggests, there are multiple input variables affecting a single output variable. Extension of
SISO ARX and FIR models to MISO system is straightforward as shown below

𝐵1 (𝑞−1 ) 𝐵2 (𝑞 −1 ) 𝑒(𝑘)
ARX MISO model: 𝑦(𝑘) = −1
𝑢1 (𝑘) + −1
𝑢2 (𝑘) + ⋯ +
𝐴(𝑞 ) 𝐴(𝑞 ) 𝐴(𝑞 −1 )
𝑀1 𝑀2

FIR MISO model: 𝑦(𝑘) = ෍ 𝑔1,𝑖 𝑢1 (𝑘 − 𝑖) + ෍ 𝑔2,𝑖 𝑢2 (𝑘 − 𝑖) + ⋯ + 𝑣(𝑘)


𝑖=1 𝑖=1

In the expression above for the ARX MISO model, the denominator polynomial is assumed to
be the same, A(q-1), in the transfer operators for all the inputs. This is a special case of general
MISO ARX model which uses different denominator polynomials (which however leads to
nonlinear parameter estimator problem). For MIMO (multi-input multi-output) systems, the
usual approach is to build separate MISO models for each output. For example, for a 2-output
2-input system, your ARX model could look as follows

𝐴1 (𝑞 −1 )𝑦1 (𝑘) = 𝐵11 (𝑞−1 )𝑢1 (𝑘) + 𝐵12 (𝑞−1 )𝑢2 (𝑘) + 𝑒1 (𝑘)

𝐴2 (𝑞−1 )𝑦2 (𝑘) = 𝐵21 (𝑞 −1 )𝑢1 (𝑘) + 𝐵22 (𝑞−1 )𝑢2 (𝑘) + 𝑒2 (𝑘)

It is not difficult to see that the above framework of independent parametrization of y 1’s and
y2’s ARX MISO models would be sub-optimal if there are correlated parameters among the
two MISO models. It would definitely be wiser to identify models for all the outputs
simultaneously. Moreover, as is apparent, both FIR and ARX models employ a large number
of parameters for MIMO case which makes model fitting prone to overfitting and necessitates
large dataset. Fortunately, specialized techniques for MIMO SysID do exist. However, we will
hold off our discussion of MIMO modeling techniques for a bit and instead look at other popular
I/O modeling techniques in the next chapter that overcome the shortcomings of ARX models.

This completes our quick look at two of the most popular classical linear dynamic models.
Negligible computational burden, global optimal solution, and only a little demand for prior
process knowledge have contributed to these models’ sustained popularity. By being exposed
to their respective pros and cons, we hope that you have a good understanding of what you
are signing up for (e.g., the implicit noise model in ARX model) when employing these models.
If you find yourself in an inadvertent situation where ARX and FIR models fail to provide
118
`

satisfactory performances, then you might need to play with your noise model. The next
chapter aims to equip you with the requisite tools necessary to accomplish this.

Summary

In this chapter we studied in detail the concepts behind FIR and ARX modeling and looked at
the pros and cons of these models. Industrially relevant case-study was illustrated to
showcase the implementation details. Next, we will move on to learn about more generic linear
modeling framework (of which ARX and FIR models can be considered special cases) which
will add some powerful techniques to your SysID arsenal.

119
`

Chapter 7
Input-Output Modeling - Part 2:
Handling Process Noise the Right Way

I
n the previous chapter we saw that the FIR and high-order models can provide unbiased
and linear-in-parameter models, but, unfortunately, suffer from high variance errors due to
large number of parameters. Therefore, in this chapter, we will look at other popular model
structures, namely, ARMAX, OE, and Box-Jenkins, that can provide more parsimonious
description of the underlying process and generate unbiased models. These models allow
greater flexibility in noise dynamics and capture the fact that noise may enter (or originate in)
the system at different points which, in turn, determines the structure of the noise transfer
operator. However, there is no free lunch! These models generate non-linear-in-parameter
predictors and therefore the parameter estimation procedures are computationally more
complex. Nonetheless, addition of these models to your ML-DPM toolkit will allow you to
choose model structure specific to the problem at hand.

In the later part of this chapter, we will relax the stationarity conditions on disturbance signals
and look at how to model processes with non-stationary disturbances. We will see how
differencing input and output signals helps in removing disturbance non-stationarities. Using
simulated illustrations, we will try to understand the implications of choosing these model
structures. Specifically, we will study the following topics.
• Introduction to ARMAX and Box-Jenkins models
• Modeling distillation columns using ARMAX models
• Introduction to OE model structure and its comparison to ARX model structure
• Introduction to ARIMAX models
• Modeling gas furnace systems using Box-Jenkins models

120
`

7.1 PEM Models

In Chapter 6, we saw how the ARX model provides a very restrictive treatment of the process
disturbances. We also saw how this shortcoming can lead to significant model bias.
Accordingly, the focus in this chapter is to overcome this shortcoming and look at other
popular alternatives to ARX model, namely, the output error (OE) model, the autoregressive
moving average with eXogenous (ARMAX) inputs model, and the Box-Jenkins (BJ) model.
As shown in Figure 7.1, these parametric models provide a broad spectrum of options
regarding the parametrization of the noise transfer operator (H). For example, while
disturbances are not modeled and only input transfer operator is sought in OE framework,
completely independent parametrization of both G and H operators are allowed in the BJ
model. In the next few sections, we will explore these models’ properties and learn how to use
them judiciously.

OE model ARX model

v(k) e(k)
[No model]
u(k) 𝐵(𝑞 −1 ) y(k) u(k) 1 y(k)
𝑞 −𝑑 𝑞 −𝑑 𝐵(𝑞 −1 ) OE
𝐴(𝑞 −1 ) 𝐴(𝑞 −1 ) N
o
i
• Disturbance directly perturbs the output • White noise enters early in the process such s
• No attempt is made to model v(k) that it shares dynamics with u(k) e
ARX
m
o
d
e
Box-Jenkins model ARMAX model l

s
𝐶(𝑞 −1 ) e(k) ARM
e(k) 𝐶(𝑞 −1 ) p
AX
𝐷(𝑞 −1 ) v(k) v(k) e
c
u(k) y(k) t
y(k) 1
u(k) −𝑑
𝐵(𝑞 −1 ) 𝑞 −𝑑 𝐵(𝑞 −1 ) r
𝑞 𝐴(𝑞 −1 ) u
𝐴(𝑞 −1 )
m BJ

• Disturbance is modeled as an ARMA • An MA stochastic signal enters early in the [Most general]
stochastic process process and shares dynamics with u(k)

Figure 7.1: Model structure of PEM models

All the models in Figure 7.1 belong to the family of prediction error methods wherein the model
parameters are estimated by minimizing the one-step ahead prediction errors (ε(k)) where,
121
`

𝜀(𝑘) = 𝑦(𝑘) − 𝑦̂(𝑘|𝑘 − 1)

Optimal model prediction based on information up to time k-1

Using the transfer operator model form, an expression for 𝑦̂(𝑘|𝑘 − 1) in terms of past (input
and output) measurements (and predictions in some cases) can be easily derived to give the
following expression

𝑦̂(𝑘) = ሾ1 − 𝐻 −1 ሿ 𝑦(𝑘) + 𝐻 −1 𝐺 𝑢(𝑘) eq. 1

We will use Eq. 154 in the coming sections to derive the difference equation expressions for
the model predictions.

PEM predictors

To derive the expression for PEM model predictions, we can follow the below steps.

𝑦(𝑘) = 𝐺 𝑢(𝑘) + 𝐻 𝑒(𝑘)


⇒ 𝐻 −1 𝑦(𝑘) = 𝐻 −1 𝐺 𝑢(𝑘) + 𝑒(𝑘)
⇒ 𝑦(𝑘) + 𝐻 −1 𝑦(𝑘) = 𝑦(𝑘) + 𝐻 −1 𝐺 𝑢(𝑘) + 𝑒(𝑘)
⇒ 𝑦(𝑘) = ሾ1 − 𝐻 −1 ሿ 𝑦(𝑘) + 𝐻 −1 𝐺 𝑢(𝑘) + 𝑒(𝑘)

eq. 1 ⇒ 𝑦̂(𝑘) = ሾ1 − 𝐻 −1 ሿ 𝑦(𝑘) + 𝐻 −1 𝐺 𝑢(𝑘)


Since e(k) is white noise, it’s most
probable value at time k is zero

𝑞 −𝑑 𝐵 1
Let’s use the above predictor for ARX model where 𝐺 = and 𝐻 = 𝐴. Eq. 1 gives
𝐴

𝑦̂(𝑘) = ሾ1 − 𝐴ሿ 𝑦(𝑘) + 𝑞−𝑑 𝐵 𝑢(𝑘)

⇒ 𝑦̂(𝑘) = −𝑎1 𝑦(𝑘 − 1) − 𝑎2 𝑦(𝑘 − 2) ⋯ − 𝑎𝑛𝑎 𝑦(𝑘 − 𝑛𝑎 )


+ 𝑏1 𝑢(𝑘 − 𝑑 − 1) + ⋯ + 𝑏𝑛𝑏 𝑢(𝑘 − 𝑑 − 𝑛𝑏 )

The above expression for ARX predictor could also have been obtained by simply setting
e(k) to zero in the ARX model’s difference equation.

54
To be read as 𝑦̂(𝑘) = ሾ1 − 𝐻−1 (𝑞−1 )ሿ 𝑦(𝑘) + 𝐻−1 (𝑞−1 ) 𝐺(𝑞−1 ) 𝑈(𝑘). We will skip the q notation in certain
expressions for presentation clarity.
122
`

7.2 ARMAX Models: An Introduction

Autoregressive moving average with eXogenous inputs (ARMAX) model is extension of


ARMA time series model to I/O systems. As shown in Figure 7.2, the current output value is
related to the past measurements of inputs and outputs, and the past noise values as well!
With ARMA disturbances, greater flexibility is provided to the noise model (compared to ARX)
and therefore, ARMAX is a popular model for industrial processes. Note that if nc= 0, then
ARMAX model reduces to an ARX model, and if additionally, na= 0, then a FIR model results.
Also note that the G and H operators are not independently parametrized due to the common
denominator polynomial, and therefore, the potential for model bias (due to inaccurate noise
model) remains.

ARMAX difference equation form

𝑦(𝑘) + 𝑎1 𝑦(𝑘 − 1) + ⋯ + 𝑎𝑛𝑎 𝑦(𝑘 − 𝑛𝑎 ) = 𝑏1 𝑢(𝑘 − 𝑑 − 1) + ⋯ + 𝑏𝑛𝑏 𝑢(𝑘 − 𝑑 − 𝑛𝑏 )


+𝑐1 𝑒(𝑘 − 1) + ⋯ + 𝑐𝑛𝑐 𝑒(𝑘 − 𝑛𝑐 ) + 𝑒(𝑘)
or
𝑛𝑎 𝑛𝑏 𝑛𝑐

𝑦(𝑘) = − ෍ 𝑎𝑖 𝑦(𝑘 − 𝑖) + ෍ 𝑏𝑖 𝑢(𝑘 − 𝑑 − 𝑖) + ෍ 𝑐𝑖 𝑒(𝑘 − 𝑖) + 𝑒(𝑘)


𝑖=1 𝑖=1 𝑖=1

ARMAX transfer operator form

𝑞 −𝑑 𝐵(𝑞 −1 ) 𝐶(𝑞 −1 )
𝑦(𝑘) = 𝑢(𝑘) + 𝑒(𝑘)
𝐴(𝑞 −1 ) 𝐴(𝑞 −1 )
where,

𝐴(𝑞 −1 ) = 1 + 𝑎1 𝑞−1 + ⋯ + 𝑎𝑛𝑎 𝑞−𝑛𝑎


𝐵(𝑞 −1 ) = 𝑏1 𝑞−1 + ⋯ + 𝑏𝑛𝑏 𝑞−𝑛𝑏
𝐶(𝑞 −1 ) = 1 + 𝑐1 𝑞−1 + ⋯ + 𝑐𝑛𝑐 𝑞−𝑛𝑐

Figure 7.2: ARXMAX (𝑛𝑎 , 𝑛𝑏 , 𝑛𝑐 ) with delay d model structure for SISO system

123
`

ARMAX predictor
To derive an expression for the 1-step ahead prediction, we may simply replace the
unpredictable part e(k) in the difference equation form of ARMAX to zero and get the following

𝑛𝑎 𝑛𝑏 𝑛𝑐

𝑦̂(𝑘) = − ෍ 𝑎𝑖 𝑦(𝑘 − 𝑖) + ෍ 𝑏𝑖 𝑢(𝑘 − 𝑑 − 𝑖) + ෍ 𝑐𝑖 𝑒(𝑘 − 𝑖)


eq. 2
𝑖=1 𝑖=1 𝑖=1

Alternatively, Eq. 1 can be used as well:

𝐴(𝑞 −1 ) 𝐴(𝑞 −1 ) 𝑞 −𝑑 𝐵(𝑞 −1 )


𝑦̂(𝑘) = [1 − ] 𝑦(𝑘) + 𝑢(𝑘)
𝐶(𝑞 −1 ) 𝐶(𝑞 −1 ) 𝐴(𝑞 −1 )

⇒ 𝐶(𝑞 −1 )𝑦̂(𝑘) = ሾ𝐶(𝑞 −1 ) − 𝐴(𝑞 −1 )ሿ 𝑦(𝑘) + 𝑞 −𝑑 𝐵(𝑞 −1 )𝑢(𝑘)

𝑛𝑐 𝑛𝑎 𝑛𝑐 𝑛𝑏

⇒ 𝑦̂(𝑘) = ෍ 𝑐𝑖 𝑦(𝑘 − 𝑖) − ෍ 𝑎𝑖 𝑦(𝑘 − 𝑖) − ෍ 𝑐𝑖 𝑦̂(𝑘 − 𝑖) + ෍ 𝑏𝑖 𝑢(𝑘 − 𝑑 − 𝑖)


𝑖=1 𝑖=1 𝑖=1 𝑖=1

Current prediction is a function


of past predictions as well

The above expression can also be derived from Eq. 2 by substituting 𝑒(𝑘) = 𝑦(𝑘) − 𝑦̂(𝑘).
Another noteworthy point is that the ARMAX predictor is nonlinear-in-unknowns during model
𝑛𝑐
fitting due to the product terms in σ𝑖=1 𝑐𝑖 𝑦̂(𝑘 − 𝑖) and therefore, nonlinear optimization is
needed for parameter estimation.

124
`

7.3 ARMAX Modeling of Distillation Columns

To showcase an industrial application of ARMAX models, we will use a simulated dataset


from a distillation column. The ubiquity and importance of distillation columns in process
industry cannot be overstated. Figure 7.3 shows a schematic of one such column wherein the
incoming feed is separated into a top product (distillate) and a bottoms product. Strict control
of the product flows and concentrations is critical for optimal column operations and the
heating power (QB) supplied to the reboiler which drives the vapor flow in the column is a
commonly used manipulated variable. Therefore, we will attempt to build a dynamic model
between the distillate concentration (XD) and QB to help the column controller operate the unit
efficiently. To obtain the model, we will use data provided in the file
DistillationColumn_SNR10.csv which contains 1000 samples of QB and XD obtained from an
open-loop simulation of the system wherein QB was excited using a GBN signal.55

Figure 7.3: Representative schematic of a distillation column used in process industry

Let’s start by importing the required packages and exploring the provided I/O dataset.

# import packages
import matplotlib.pyplot as plt, numpy as np, control

55
The model for the distillation column was taken from ‘Digital control systems: design, identification and
implementation. Springer, 2006’.
125
`

from sklearn.preprocessing import StandardScaler


from sippy import system_identification as SysID
from statsmodels.graphics.tsaplots import plot_acf
from statsmodels.tsa.stattools import ccf

# read distillation column data and plot


data = np.loadtxt(DistillationColumn_SNR10.csv', delimiter=',')
u = data[:,0, None] # QB
y = data[:,1, None] # XD

plt.figure(), plt.plot(u, 'steelblue'), plt.ylabel('u(k)'), plt.xlabel('k')


plt.figure(), plt.plot(y, 'g'), plt.ylabel('y(k)'), plt.xlabel('k')

Next, we will center the data and fit an ARX model using AIC.

# center data and fit ARX model


u_scaler = StandardScaler(with_std=False); u_centered = u_scaler.fit_transform(u)
y_scaler = StandardScaler(with_std=False); y_centered = y_scaler.fit_transform(y)

ARXmodel = SysID(y_centered, u_centered, 'ARX', IC='AIC', na_ord=[1,10], nb_ord=[1,10], delays=[0,2])


# delay range obtained from FIR model

>>> suggested orders are: Na= 5 ; Nb= 5 Delay: 1

The obtained ARX model is of pretty high order. We have studied previously that high-order
ARX models become necessary to negate the impact of inaccurate specification of
disturbance dynamics. Therefore, it is reasonable to attempt an ARMAX model with the hope
of obtaining a more parsimonious model.

# fit ARMAX model


ARMAXmodel = SysID(y_centered, u_centered, 'ARMAX', IC='AIC', na_ord=[1,10], nb_ord=[1,10],
nc_ord=[1,10], delays=[0,2], max_iterations=1000)

126
`

>>> Armax model:


- Params:
na: 2 (1, 10)
nb: 3 (1, 10)
nc: 2 (1, 10)
delay: 0 (0, 2)

As hoped, the ARMAX model’s size is reasonable. A quick residual check (plots shown below)
build some confidence into the model.

To build further confidence into the model, we check the step responses from FIR, ARX, and
the ARMX models. The close match of the step responses further validates the model.

Step responses from different


models match.

127
`

7.4 OE Models: An Introduction

Output error (OE) models lie at the extreme end of PEM modeling spectrum wherein no model
is postulated for the disturbance signal and only the effects of inputs on the output variable
are modeled as shown in Figure 7.4. Accordingly, v(k) is completely ignored for model
predictions. Since no past output information is used and past predictions are used for future
predictions, one-step ahead prediction equals m-step ahead predictions (for any m) and
infinite-step prediction as well. In other words, simulation and prediction responses coincide
for OE model!56 Figure 7.4 also tells us that the predictor is nonlinear-in-unknowns during
model fitting and therefore, like ARMAX57, nonlinear optimization is required for parameter
optimization.

OE transfer operator form OE’s 1-step ahead predictor

𝑞 −𝑑 𝐵(𝑞 −1 ) 𝑞 −𝑑 𝐵(𝑞 −1 )
𝑦(𝑘) = 𝑢(𝑘) + 𝑣(𝑘) 𝑦̂(𝑘) = 𝑢(𝑘)
𝐴(𝑞 −1 ) 𝐴(𝑞 −1 )
where,

𝐴(𝑞 −1 ) = 1 + 𝑎1 𝑞−1 + ⋯ + 𝑎𝑛𝑎 𝑞−𝑛𝑎 OE difference equation form


𝐵(𝑞 −1 ) = 𝑏1 𝑞−1 + ⋯ + 𝑏𝑛𝑏 𝑞−𝑛𝑏 𝑛𝑎 𝑛𝑏

𝑦̂(𝑘) = − ෍ 𝑎𝑖 𝑦̂(𝑘 − 𝑖) + ෍ 𝑏𝑖 𝑢(𝑘 − 𝑑 − 𝑖)


𝑖=1 𝑖=1

Figure 7.4: OE model structure and one-step ahead predictor for SISO system

There is no issue of parametrization dependency between G and H operators and therefore,


OE models generate unbiased deterministic models. Therefore, when one is not sure of noise
characteristics, OE models are preferred to provide unbiased input transfer operator. The
corresponding residuals (𝑦(𝑘) − 𝑦̂𝑂𝐸 (𝑘)) are of course not bound to satisfy whiteness
conditions and therefore, ACF test is not imposed during model diagnostics; CCF test,
however, would still apply. Very often, a time-series model is fit to the residual sequence to
approximate the noise transfer operator as shown in Figure 7.5 below. You can take the
approximated model as your final model or use this as an initial estimate in a Box-Jenkins
model estimation procedure to obtain a better model.

56 𝐵(𝑞 −1 )
For any PEM model, 𝑦̂(𝑘) = 𝑢(𝑘) gives infinite-step predictions/simulation responses.
𝐴(𝑞 −1 )
57
If v(k) = e(k), then OE becomes special case of ARMAX model with 𝐶(𝑞 −1 ) = 𝐴(𝑞 −1 )
128
`

{u(k), y(k)}

𝑦̂(𝑘) Residuals 𝑣(𝑘)


OE Model (𝑦 − 𝑦̂(𝑘)) TSA

𝐺(𝑞 −1 ) 𝐻(𝑞 −1 )

𝑦(𝑘) ≈ 𝐺(𝑞 −1 )𝑢(𝑘) + 𝐻(𝑞 −1 )𝑒(𝑘)

Figure 7.5: Approximating a process model through separate estimation of deterministic and
stochastic components.

Example 7.1:
In example 6.2 in the previous chapter, we provided a comparison between ARX and
OE model performances for modeling the below process. In this example, we will see
how those OE models were fitted.

0.7𝑞−1 1
𝑦(𝑘) = −1
𝑢(𝑘) + 𝑒(𝑘)
1 − 0.7𝑞 1 − 0.2𝑞−1

We will also see how the overall process model can be obtained through separate
estimation of deterministic and stochastic components. The code for importing packages
and reading and pe-processing the dataset remains the same as in Example 6.2. We will
use the dataset with SNR = 10.

# fit ARX model


OEmodel = SysID(y_centered, u_centered, 'OE', IC='AIC', nb_ord=[1,5], nf_ord=[1,5], delays=[0,5])
# SIPPY uses the symbol F to denote denominator polynomial of transfer operator G
print(OEmodel.G)
0.6704𝑞−1
𝐺(𝑞 −1 ) =
1 − 0.7052𝑞−1

OE model approximated the deterministic component much better than the ARX model
and therefore, it is not surprising that its step response was closer to the true step
response. Let’s see if the residuals pass the diagnostics check. As alluded to before, OE
models need not be tested for whiteness of residuals.

129
`

# get model predictions and residuals on training dataset


y_predicted_centered = OEmodel.Yid
y_predicted = np.transpose(y_scaler.inverse_transform(y_predicted_centered))
residuals = y - y_predicted

# CCF b/w residuals and input sequence


ccf_vals = ccf(residuals, u, adjusted=False) # ccf for lag >= 0
ccf_vals = ccf_vals[:21] # ccf for lag 0 to 20

# plot
plt.figure(figsize=(6,4)), plt.vlines(lags, [0], ccf_vals), plt.axhline(0, 0, lags[-1])
plt.plot(lags, ccf_vals, marker='o', markersize=5, linestyle='None')
plt.gca().axhspan(-conf_int, conf_int, facecolor='lightblue', alpha=0.5) # shaded confidence interval
plt.xlabel('lag'), plt.title('Cross-correlations')

No correlations exist between


the residual and the input
sequences

Alright, now that we have successfully obtained the deterministic component, let’s see if
the model residuals can help us obtain the stochastic component. For this, we will need
to fit a time-series model to the residuals as shown in Figure 7.5 and we already know
that ACF/PACF plots can provide clues about the candidate models.

The exponential decay of ACF


and sharp cut-off of PACF at
lag 1 suggests an AR(1) model
which is consistent with the
true process!

130
`

7.5 Box-Jenkins Models: An Introduction

Box-Jenkins (BJ) model relaxes the restriction of (common A(q-1) polynomial in G and H
operators in) ARMAX model and uses disturbance signal dynamics completely different from
the deterministic dynamics. As shown in Figure 7.6, G and H operators are independently
parameterized which ensures unbiased deterministic model estimation. Expectedly, the
model expressions are more complex and requires specification of 5 hyperparameters, vis-a-
vis, na, nb, nc, nd, d. Moreover, nonlinear optimization is required for model fitting. Let’s see a
quick example of modeling an industrial gas-furnace system via BJ model.

BJ transfer operator form

𝑞 −𝑑 𝐵(𝑞 −1 ) 𝐶(𝑞 −1 )
𝑦(𝑘) = 𝑢(𝑘) + 𝑒(𝑘) BJ’s 1-step ahead predictor
𝐴(𝑞 −1 ) 𝐷(𝑞 −1 )
where,
𝐷(𝑞 −1 ) 𝑞 −𝑑 𝐷(𝑞 −1 )𝐵(𝑞 −1 )
𝑦̂(𝑘) = [1 − ] 𝑦(𝑘) + 𝑢(𝑘)
𝐴(𝑞 −1 ) = 1 + 𝑎1 𝑞−1 + ⋯ + 𝑎𝑛𝑎 𝑞−𝑛𝑎 𝐶(𝑞 −1 ) 𝐶(𝑞 −1 )𝐴(𝑞 −1 )
𝐵(𝑞 −1 ) = 𝑏1 𝑞−1 + ⋯ + 𝑏𝑛𝑏 𝑞−𝑛𝑏
𝐶(𝑞 −1 ) = 1 + 𝑐1 𝑞−1 + ⋯ + 𝑐𝑛𝑐 𝑞−𝑛𝑐
𝐷(𝑞 −1 ) = 1 + 𝑑1 𝑞 −1 + ⋯ + 𝑑𝑛𝑑 𝑞−𝑛𝑑

BJ difference equation form

To see the difference equation form, let’s consider the following for convenience

𝐴(𝑞 −1 ) = 1 + 𝑎1 𝑞−1 , 𝐵(𝑞 −1 ) = 𝑏1 𝑞−1, 𝐶(𝑞 −1 ) = 1 + 𝑐1 𝑞 −1 , 𝐷(𝑞 −1 ) = 1 + 𝑑1 𝑞 −1


𝑑=0

Then,

𝑏1 𝑞−1 1 + 𝑐1 𝑞−1
𝑦(𝑘) = 𝑢(𝑘) + 𝑒(𝑘)
1 + 𝑎1 𝑞−1 1 + 𝑑1 𝑞 −1

⇒ 𝑦(𝑘) + (𝑎1 + 𝑑1 )𝑦(𝑘 − 1) + 𝑎1 𝑑1 𝑦(𝑘 − 2) = 𝑏1 𝑢(𝑘 − 1) + 𝑏1 𝑑1 𝑢(𝑘 − 2) +


(𝑎1 + 𝑐1 )𝑒(𝑘 − 1) + 𝑎1 𝑐1 𝑒(𝑘 − 2) + 𝑒(𝑘)

Figure 7.6: Box-Jenkins model structure for SISO system

131
`

Example 7.2:
In this illustration, we will use the popular Box-Jenkins gas furnace dataset
(https://www.itl.nist.gov/div898/handbook/pmc/section4/pmc451.htm). The data comes
from a SISO gas furnace wherein methane was combusted. The methane feed rate is
the input, the CO2 concentration in the gases exiting the furnace is the output, and 296
samples recorded at 9-second intervals are provided. We will build a BJ model for this
dataset using SIPPY. The code is almost identical to that in the previous example.

# read data
data = np.loadtxt('gas-furnace.csv', delimiter=',')
u = data[:,0, None]; y = data[:,1, None]

# center data
u_scaler = StandardScaler(with_std=False); u_centered = u_scaler.fit_transform(u)
y_scaler = StandardScaler(with_std=False); y_centered = y_scaler.fit_transform(y)

# fit BJ model
BJmodel = SysID(y_centered, u_centered, 'BJ', IC='AIC', nb_ord=[3,3], nc_ord=[1,1], nd_ord=[2,2],
nf_ord=[2,2], delays=[2,2], max_iterations=500)
# see SIPPY user-guide for details on symbols used for transfer operator polynomials
print(BJmodel.G)
print(BJmodel.H)
𝑞 −2 (−0.53𝑞−1 − 0.38𝑞−2 − 0.51𝑞−3 )
𝐺(𝑞 −1 ) =
1 − 0.56𝑞 −1 + 0.01𝑞−2
1 + 0.05𝑞−1 )
𝐻(𝑞 −1 ) =
1 − 1.50𝑞 −1 + 0.60𝑞−2

The obtained polynomials of the transfer operators are very close to those reported in
the original source (Box et al., Time Series Analysis: Forecasting and Control, Wiley).
The above model also (almost) passes the residual diagnostics check as shown below
by the ACF and CCF plots of the residuals.

132
`

7.6 ARIMAX Models: An Introduction

So far we have worked under the assumption that the process disturbances (v(k)) are
stationary. However, this may not always be true. Nonetheless, if v(k) is difference stationary,
𝐶(𝑞 −1 )
then it can be modeled as an ARIMA process: 𝑣(𝑘) = 𝑒(𝑘) where d is the
(1−𝑞 −1 )𝑑 𝐴(𝑞 −1 )
differencing order58, and the final model looks as shown in Figure 7.7.

ARIMAX block diagram

e(k) 𝐶(𝑞 −1 )
(1 − 𝑞 −1 )𝑑 𝐴(𝑞 −1 ) v(k)

𝐵 𝐶
u(k) 𝐵(𝑞 −1 ) 𝑦(𝑘) = 𝑞 −𝑛𝑑 𝑢(𝑘) + 𝑒(𝑘)
𝑞 −𝑛𝑑 𝐴 (1 − 𝑞 −1 )𝑑 𝐴
𝐴(𝑞 −1 )

Figure 7.7: Model structure of ARIMAX. Note that here d denotes the differencing order and
not the process delay.

Let’s do some quick algebraic manipulation to understand the implications of employing this
model.

𝐵(𝑞 −1 ) 𝐶(𝑞 −1 )
ARIMAX model: 𝑦(𝑘) = 𝑞 −𝑛𝑑 𝑢(𝑘) + 𝑒(𝑘)
𝐴(𝑞 −1 ) (1 − 𝑞 −1 )𝑑 𝐴(𝑞 −1 )

𝐵(𝑞 −1 ) 𝐶(𝑞 −1 )
⇒ (1 − 𝑞 −1 )𝑑 𝑦(𝑘) = 𝑞 −𝑛𝑑 (1 − 𝑞 −1 𝑑
) 𝑢(𝑘) + 𝑒(𝑘)
𝐴(𝑞 −1 ) 𝐴(𝑞 −1 )

𝐵(𝑞 −1 ) 𝐶(𝑞 −1 )
⇒ 𝑦෤(𝑘 ) = 𝑞 −𝑛𝑑 𝑢
෤ (𝑘 ) + 𝑒(𝑘)
𝐴(𝑞 −1 ) 𝐴(𝑞 −1 )

where 𝑦෤(𝑘) = (1 − 𝑞 −1 )𝑑 𝑦(𝑘)


ARMAX model!
𝑢෤(𝑘) = (1 − 𝑞 −1 )𝑑 𝑢(𝑘)

58
As remarked in Chapter 5, d is usually ≤ 2
133
`

The expression above shows that ARIMAX model is equivalent to ARMAX model on
differenced input and output signals! Moreover, getting ARMAX model on differenced data
provides an unbiased estimate of the deterministic model or the input transfer operator G
between u(k) and y(k). Like ARIMA models, ARIMAX should be used with caution or only
when necessary. If v(k) does not have any integration non-stationarity, then differencing u(k)
and y(k) will only amplify noise and reduce SNR. One way to ascertain disturbance non-
stationarity is to fit an OE model on undifferenced data and then assess the properties of the
residuals (via ACF/PACF or unit root tests). Let’s work out an example to understand the
methodology better.

Example 7.3:
In this example, we will re-use the true process from Example 7.1 with a modification of
the AR coefficient in the disturbance model that now has an integrating term as well as
shown below.

0.7𝑞−1 1
𝑦(𝑘) = −1
𝑢(𝑘) + 𝑒(𝑘)
1 − 0.7𝑞 (1 − 𝑞 )(1 − 0.7𝑞 −1 )
−1

We will see how the true deterministic component can be recovered by working with
differenced input and output signals.

# import packages
import matplotlib.pyplot as plt, numpy as np, control
from sklearn.preprocessing import StandardScaler
from sippy import system_identification as SysID
from statsmodels.graphics.tsaplots import plot_acf

# read data
data = np.loadtxt('ARIMAX_illustrate_SNR15.csv', delimiter=',')
u = data[:,0, None]; y = data[:,1, None]

# center data
u_scaler = StandardScaler(with_std=False); u_centered = u_scaler.fit_transform(u)
y_scaler = StandardScaler(with_std=False); y_centered = y_scaler.fit_transform(y)

#%% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
# Fit OE model and check residual non-stationarity
#% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
OEmodel = SysID(y_centered, u_centered, 'OE', OE_orders=[1,1,0])
y_predicted_OE = y_scaler.inverse_transform(np.transpose(OEmodel.Yid))
OEresiduals = y - y_predicted_OE

134
`

The ACF plots below show the autocorrelation of the residual sequence before and after
differencing. It is clear that the process is impacted by non-stationary disturbance and
the non-stationarity goes away after the first differencing of the residuals. Guided by
these observations, we will build an ARMAX model after differencing the input and output
signals once.

plot_acf(OEresiduals) plot_acf(np.diff(OEresiduals, axis=0))

#%% %%%%%%%%%%%%%%%%%%%%%%%
# Fit ARIMAX model
#% %%%%%%%%%%%%%%%%%%%%%%%%
# difference I/O data once
u_centered_delta = np.diff(u_centered, axis=0)
y_centered_delta = np.diff(y_centered, axis=0)

# fit ARMAX model on differenced data


ARMAXmodel = SysID(y_centered_delta, u_centered_delta, 'ARMAX', ARMAX_orders=[1,1,0,0])
print(ARMAXmodel.G)
print(ARMAXmodel.H) 1
0.6999𝑞−1
𝐺(𝑞 −1 ) = ; 𝐻(𝑞 −1 ) =
1 − 0.6988𝑞−1 1 − 0.6988𝑞−1

0.6999𝑞−1 1
∆𝑦(𝑘) = −1
∆𝑢(𝑘) + 𝑒(𝑘)
1 − 0.6988𝑞 1 − 0.6988𝑞−1

0.6999𝑞−1 1
𝑦(𝑘) = −1
𝑢(𝑘) + 𝑒(𝑘)
1 − 0.6988𝑞 (1 − 𝑞 )(1 − 0.6988𝑞−1 )
−1

We have obtained a very close estimate of the true process! The differenced input and
output sequences may seem very different, but as shown in this example, they obey the
same deterministic relationship.

135
`

What model structure to choose?


With quite a few models at your disposal, you have all the rights to ask,
‘how to choose the best model for my system?’ Unfortunately, there is
no definite answer. However, the concepts covered in the current and
the previous chapters can help you choose the right path to your answer
and, most importantly, understand the implications of choosing any
model structure.

A trivial approach may be to try and fit a generic ARIMAX model, but this
won’t be a wise approach because you may end up with nonexistent
dynamic in your G and H operators due to noisy data. Obtaining the most
simple and parsimonious model should be your guiding mantra! In
general, the selection of model structure will largely depend on the
extent of prior information/insights you have about the system,
specifically about the disturbance signals such as if the noise enters
early or late in the process or if the disturbances have drift tendencies.
Other major selection criterion is the end goal: you may be interested
only in the deterministic model (to be used for simulation for example)
or also in the noise model (for better predictions). Of course, SNR,
amount of available data, and ease of estimation are also crucial
determining factors.

One school of thought recommends employing an OE model to estimate


G, studying the residual characteristics to approximate H, and then using
these estimates as initial guess for a BJ model for obtaining improved
estimates. In another school of thought, ARX is the preferred initial
model choice.

Do note that we remained focused on SISO systems in Chapters 6 and


7. You can imagine that it would be quite a tedious task to find the
optimal combination of model orders for the polynomials for all the G and
H operators for all the input and outputs in a MIMO model. The state-
space models introduced in the next chapter will make your life very
easy for modeling MIMO systems as you won’t need to pre-specify all
those model orders. Therefore, hold your horses tight, more modeling
options are coming your way!

136
`

Summary

In this chapter we looked at classical PEM models for modeling linear SISO systems. We
learnt the pros and cons of ARMAX, OE, BJ, and ARIMAX models. We saw their applications
for modeling distillation columns and gas furnaces. You now have all the tools available to
make educated selection of your model structure. To further strengthen your modeling
capabilities, let’s move on to the study of state-space and subspace models for MIMO
systems.

137
`

Chapter 8
State-Space Models:
Efficient Modeling of MIMO Systems

I
n the previous chapter we alluded to the problems related to the classical methodology of
modeling a MIMO system through separate MISO models for each output. In a physical
system, the different output variables seldom behave independently; they often share
common parameters and/or correlated noise. Therefore, identifying all the output models
simultaneously while being cognizant of shared dynamics between them leads to better and
more robust models. This alternative approach to SysID is provided by state-space (SS)
models. State-space models add an intermediate layer of ‘state variables’ between the input
and output variables, wherein, the inputs determine the states, and the outputs are derived
as linear combination of the states. This modeling paradigm leads to parsimonious models
capable of fitting complex processes with both fast and slow dynamics.

In this chapter, we will cover in detail the subspace identification techniques which are utilized
for fitting the SS models. While several popular subspace identification methods (SIMs) such
as N4SID, CVA, MOESP exist, CVA will be our primary focus. Subspace identification offers
several additional advantages over I/O models. SIMs involve only linear algebra for model ID
(no iterative nonlinear optimization schemes are needed). SIMs also provide in-situ
mechanism for automated optimal model order selection. Subspace models are more robust
to noise and provide smooth (step and impulse) response curves. Infact, it is not uncommon
to fit SIM model to I/O data and then derive FIR model using the SIM model for usage in MPC
applications. Due to such superior properties of SIM, they are among the ‘mainstream’ models
provided by advanced process control (APC) solution vendors.

CVA models are also inherently suitable for computing fault detection indices, performing fault
diagnosis, and therefore building process monitoring tools. We will build one such application
in this chapter. Specifically, the following topics will be covered
• Introduction to state-space models and CVA modeling
• Modeling MIMO glass furnace via CVA
• Process monitoring of Industrial Chemical Plants using CVA

138
`

8.1 State-Space Models: An Introduction

Consider the distillation column in Figure 8.1 where we have four inputs and four outputs.
Let’s focus on the relationship between the reboiler duty QB and distillate composition xD. We
can build an I/O model between QB and xD, but it is clear that QB doesn’t affect xD directly.
There are internal dynamics or states (e.g., arising from the liquid holdup at each column tray)
that changes in QB have to pass through before impacting xD. Similar argument could be made
for QB vs D relationship. The unobserved intermediate variables which characterize the
internal dynamics or ‘states’ of the column are termed state variables and, as argued before,
the outputs share these states. The modeling framework that reflects such interrelationship
between the inputs and outputs is the state-space model whose structure59 is shown in Figure
8.1. In a generic modeling exercise, the estimated state variables may not always have any
physical meanings and even the choice of the states is not unique.

R 𝑥(𝑘 + 1) = 𝐴𝑥(𝑘) + 𝐵𝑢(𝑘) + 𝑤(𝑘)

D 𝑦(𝑘) = 𝐶𝑥(𝑘) +𝐷𝑢(𝑘) + 𝑣(𝑘)


F Feed
xD
xF
𝑢 = ሾ𝑄𝐵 , 𝑥𝐹 , 𝐹, 𝑅ሿ 𝑥(𝑘) ∈ ℝ𝑛 : State vector
QB 𝑦 = ሾ𝐷, 𝑥𝐷 , 𝐵, 𝑥𝐵 ሿ 𝑢(𝑘) ∈ ℝ𝑚 : Input vector
𝑦(𝑘) ∈ ℝ𝑟 : Output vector
B 𝑤(𝑘) ∈ ℝ𝑛 : Process noise
xB
𝑣(𝑘) ∈ ℝ𝑟 : Measurement noise
State-space ID objective
Given the I/O data sequence𝑠 {𝑢(𝑘)} = ሾ𝑢(0), 𝑢(1), ⋯ , 𝑢(𝑁 − 1)ሿ and {𝑦(𝑘)} = ሾ𝑦(0), 𝑦(1), ⋯ , 𝑦(𝑁 − 1)ሿ,

estimate the system order n, the system matrices (A, B, C, D), the initial state x(0), and the statistical properties
(covariance matrices) of the noises (𝛴𝑤𝑤 , 𝛴𝑣𝑣 )

Figure 8.1: State-space representation of a process60

Our familiar PEM methodology could be used to estimate SS models but that would involve
solving a nonlinear optimization problem. The better alternative is the subspace identification
method.61 Specifically, in the CVA (canonical variate analysis) approach, the states are
59 The matrix D is often kept equal to zero due to no immediate direct impact of u(k) on y(k)
60 Column diagram created by Milton Beychok under Creative Commons Attribution-Share Alike 3.0
[http://commons.wikimedia.org/wiki/File:Continuous_Binary_Fractional_Distillation.PNG]
61 A drawback of subspace identification is that the model fit may not be as accurate as that obtained via PEM because optimality is not guaranteed in SIM.

However, the difference is accuracy is usually not significant.


139
`

estimated via linear algebra as a linear combination of past outputs and inputs that maximizes
the explained variability in the future output measurements. Without further ado, let’s now
delve deeper into the CVA concepts and master the art of CVA-based state-space modeling.

Forms of state-space models

The form of state-space model we saw in Figure 8.1 is called process form. Two other
common forms are shown below

𝑥(𝑘 + 1) = 𝐴𝑥(𝑘) + 𝐵𝑢(𝑘) + 𝐾𝑒(𝑘) 𝑥(𝑘 + 1) = 𝐴𝑘 𝑥(𝑘) + 𝐵𝑘 𝑢(𝑘) + 𝐾𝑦(𝑘)


𝑦(𝑘) = 𝐶𝑥(𝑘) + 𝐷𝑢(𝑘) + 𝑒(𝑘) 𝑦(𝑘) = 𝐶𝑥(𝑘) + 𝐷𝑢(𝑘) + 𝑒(𝑘)

Kalman gain where 𝐴𝑘 = 𝐴 − 𝐾𝐶


𝐵𝑘 = 𝐵 − 𝐾𝐷

Any of the three forms can be chosen to model any MIMO system.

8.2 State-Space Modeling via CVA

CVA is among the most popular technique for state-space modeling of dynamic MIMO
systems. Figure 8.2 shows the general approach used by CVA (and other SIM techniques)
for estimating the SS models using historical plant data: the state sequence {x(k)} for the
historical observations are first estimated using the {y(k), u(k)} data sequences, then the
system matrices (A, B, C, D) are estimated via least-squares regression, and thereafter the
covariance matrices are found. We will see more on this procedure soon. All SIM algorithms
follow this procedure and differ primarily in the way the state sequence is estimated.

I/O data
Estimate historical states x(k)

Estimate matrices A, B, C, D
State-space model
Estimate noise covariance matrices

Figure 8.2: State-space modeling workflow

140
`

Let’s look at the model fitting procedure in more details.

Mathematical background
Using the state-space model and some smart re-arrangement62 of input-output data
sequence, it can be shown that state vector x(k) can be approximated as a linear combination
of past inputs and outputs63

unknown matrix

𝑥̂(𝑘) = 𝐽 𝑝(𝑘) eq. 1

𝑇
defined as ൣ𝑦 𝑇 (𝑘 − 1) 𝑦 𝑇 (𝑘 − 2) ⋯ 𝑦 𝑇 ൫𝑘 − 𝑙𝑦 ൯ 𝑢𝑇 (𝑘 − 1) 𝑢𝑇 (𝑘 − 2) ⋯ 𝑢𝑇 (𝑘 − 𝑙𝑢 ) ൧

In Eq. 1, ly and lu denote the number of lagged outputs and inputs used to build the p(k) vector.
Usually, ly = lu = l and it is a model hyperparameter. The CVA method utilizes CCA (canonical
covariate analysis), a multivariate statistical technique, to find J. A quick primer on the CCA
technique is provided below.

CCA: A quick primer

CCA is a dimensionality reduction technique which aims to find linear combinations of


input variables (𝑢 ∈ ℝ𝑚 ) that are maximally correlated with linear combinations of
outputs variables (𝑦 ∈ ℝ𝑝 )*. You may relate this to PLS wherein covariance between
latent variables is maximized. These linear combinations are called canonical variables
and are given as
𝑐 = 𝐽𝑢 c comprises of uncorrelated latent variables
Observations in respective
latent spaces 𝑑 = 𝐿𝑦 d comprises of uncorrelated latent variables

The covariance matrix between c and d is (rectangular) diagonal


latent variables are only
pairwise correlated
𝛴𝑐𝑑 = 𝐽𝛴𝑢𝑦 𝐿𝑇 = 𝐷 = 𝑑𝑖𝑎𝑔(𝛾1 , 𝛾2 , … , 𝛾𝑜 , 0, … , 0 )

The elements 𝛾𝑖 of matrix D are called canonical correlations with (𝛾1 ≥ 𝛾2 ≥ … ≥ 𝛾𝑜 )


th
and quantify the degree of correlations between the i canonical variate pair ci and di.

62
Chen et. al., A canonical variate analysis based process monitoring scheme and benchmark study. 2014
63
All SIM algorithms follow this procedure and differ primarily in the way the matrix J is estimated
141
`

Var 1 Var 2 Var m Var 1 Var 2 Var m Var 1 Var 2 Var r Var 1 Var 2 Var r

𝑈11 𝑈12 ⋯ 𝑈1𝑚 𝐶11 𝐶12 ⋯ 𝐶1𝑚 Ɗ11 Ɗ12 ⋯ Ɗ1𝑟 𝑌11 𝑌12 ⋯ 𝑌1𝑟
‫ۍ‬ ‫ۍ 𝐽 ې‬ ‫ې‬ ‫ۍ‬ ‫ۍ 𝐿ې‬ ‫ې‬
‫𝑈 ێ‬21 𝑈22 ⋯ 𝑈2𝑚 ‫𝐶 ێ ۑ‬21 𝐶22 ⋯ 𝐶2𝑚 ‫ۑ‬ ‫ ێ‬Ɗ21 Ɗ22 ⋯ Ɗ2𝑟 ‫𝑌 ێ ۑ‬21 𝑌22 ⋯ 𝑌2𝑟 ‫ۑ‬
‫ێ‬ ‫ێ ۑ‬ ‫ۑ‬ ‫ێ‬ ‫ێ ۑ‬ ‫ۑ‬
‫⋮ ێ‬ ⋮ ⋱ ⋮ ‫⋮ ێ ۑ‬ ⋮ ⋱ ⋮ ‫ۑ‬ ‫⋮ ێ‬ ⋮ ⋱ ⋮ ‫⋮ ێ ۑ‬ ⋮ ⋱ ⋮ ‫ۑ‬
‫ێ‬ ‫ێ ۑ‬ ‫ۑ‬ ‫ێ‬ ‫ێ ۑ‬ ‫ۑ‬
‫𝑁𝑈ۏ‬1 𝑈𝑁2 ⋯ 𝑈𝑁𝑚 ‫𝑁𝐶ۏ ے‬1 𝐶𝑁2 ⋯ 𝐶𝑁𝑚 ‫ے‬ ‫ۏ‬Ɗ𝑁1 Ɗ𝑁2 ⋯ Ɗ𝑁𝑟 ‫𝑁𝑌ۏ ے‬1 𝑌𝑁2 ⋯ 𝑌𝑁𝑟 ‫ے‬
Input data matrix Transformed matrix Transformed matrix Output data matrix
𝑈 ∈ ℝ𝑁𝑋𝑚 𝐶 ∈ ℝ𝑁𝑋𝑚 Ɗ ∈ ℝ𝑁𝑋𝑟 𝑌 ∈ ℝ𝑁𝑋𝑟

Canonical variable 𝑑2
Canonical variable 𝑑1

Canonical variable 𝐶1 Canonical variable 𝐶2

The matrices 𝐽 ∈ ℝ𝑚𝑋𝑚 and 𝐿 ∈ ℝ𝑟𝑋𝑟 are found via singular value decomposition

−1/2 −1/2
𝛴𝑢𝑢 𝛴𝑢𝑦 𝛴𝑦𝑦 = 𝑈𝛴𝑉 𝑇
−1/2 −1/2
where, 𝐽 = 𝑈 𝑇 𝛴𝑢𝑢 , 𝐿 = 𝑉 𝑇 𝛴𝑦𝑦 , 𝐷 = 𝛴

One may retain only those canonical variate pairs (say, top n pairs) that show significant
correlations and discard the others, and therefore achieve dimensionality reduction. Let
𝑐Ƹ and 𝑑መ be the n-dimensional (n < m and r) vectors, then,

𝑐Ƹ = 𝐽𝑛 𝑢
where, Jn and Ln are first n rows of J and L
𝑑መ = 𝐿𝑛 𝑦

* It is assumed that u and y are centered. Scaling, however, is not required as CCA is scale-invariant, i.e., the
estimated latent variables and the correlations remain the same with or without scaling. Also note that we have
not used the ‘k’ notation as CCA is designed for static data.

142
`

CVA states
In CVA, the two sets of vectors between which CCA is performed are p(k) (defined in Eq. 1)
and f(k) where64

𝑓(𝑘) = ሾ𝑦 𝑇 (𝑘) 𝑦 𝑇 (𝑘 + 1) ⋯ 𝑦 𝑇 (𝑘 + 𝑙)ሿ𝑇

current and future outputs

CVA therefore solves the following singular value decomposition problem and finds linear
combinations of past inputs and outputs that are maximally correlated with linear combinations
of the current and future outputs.

= 𝑈𝛴𝑉𝑇
−1/2 −1/2
𝛴𝑝𝑝 𝛴𝑝𝑓 𝛴𝑓𝑓 eq. 2

We know that Σ is a diagonal matrix. Its elements are also called (Hankel) singular values. If
n is assumed to be the model order, then the optimal state at time k that is most predictive of
the future outputs is given by65

𝑥̂ (𝑘) = 𝐽𝑛 𝑝(𝑘)
−1/2
Contains first n rows of matrix 𝐽 = 𝑈 𝑇 𝛴𝑝𝑝

System matrices
With the states estimated, the system matrices (A, B, C, D) can be estimated via multivariable
linear least-squares regression66. The final expression can be derived as

𝐴መ 𝐵෠ 𝑥̂(𝑘 + 1) 𝑥̂(𝑘) 𝑥̂(𝑘) 𝑥̂(𝑘)


[ ] = 𝑐𝑜𝑣 ([ ],[ ]) 𝑐𝑜𝑣 −1 ([ ],[ ])
𝐶መ ̂
𝐷 𝑦(𝑘) 𝑢(𝑘) 𝑢(𝑘) 𝑢(𝑘)

The noise covariance matrices, Q and R, can be estimated as the covariance matrices of the
state and output residuals, respectively.

64
The number of lead values used to define f(k) is taken equal to the number of lags used in p(k) which is a common
practice.
−1/2
65
Alternatively, 𝑥̂(𝑘) = 𝑈𝑛𝑇 𝛴𝑝𝑝 𝑝(𝑘) where Un contains the first n columns of U.
66 𝑥(𝑘 + 1) 𝐴 𝐵 𝑥(𝑘) 𝑤(𝑘)
The multivariable linear model is [ ]= [ ][ ]+ [ ]
𝑦(𝑘) 𝐶 𝐷 𝑢(𝑘) 𝑣(𝑘)
143
`

𝜀𝑥 (𝑘) = 𝑥̂(𝑘 + 1) − ൫𝐴̂ 𝑥̂(𝑘) + 𝐵̂ 𝑢(𝑘)൯ 𝑄෠ = 𝛴𝜀𝑥 𝜀𝑥

𝜀𝑦 (𝑘) = 𝑦(𝑘) − ൫𝐶̂ 𝑥̂(𝑘) + 𝐷ෝ 𝑢( 𝑘) ൯ 𝑅෠ = 𝛴𝜀𝑦𝜀𝑦

I/O data
Create sequence of vectors p(k) and f(k)

𝑝(𝑘) 𝑓(𝑘)

Perform CCA

historical state
sequence 𝑥(𝑘)

Estimate matrices A, B, C, D

Estimate noise covariance matrices


State-space model

Figure 8.3: CVA model identification workflow

Hyperparameter selection
The mathematical background of the CVA algorithm suggests specification of two
hyperparameters: the lag order (𝑙) and the model order (n). While model order specification is
not required prior to state estimation, the lag order needs to be known beforehand. Let’s see
the common approaches for estimation of these hyperparameters.

Lag order (𝑙)


The guidance for assigning a value to the lag 𝑙 is that it should be large enough to capture
data autocorrelation. A commonly recommended strategy is to fit several multivariate
autoregressive models with different values of 𝑙 and choose the 𝑙 that minimizes the AIC
criterion. For example, let 𝑙̃ be one of the trial values. Then the following relationship is set up

144
`

𝑦(𝑙̃) 𝑦(𝑙̃ + 1) ⋯ 𝑦(𝑁 − 1)


‫ۍ‬ ‫ې‬
‫)̃𝑙(𝑢 ێ‬ 𝑢(𝑙̃ + 1) ⋯ 𝑢(𝑁 − 1) ‫ۑ‬
‫ ̃𝑙(𝑦ێ‬− 1) 𝑦(𝑙̃) ⋯ ⋮ ‫ۑ‬
𝑦(𝑙̃ + 1) 𝑦(𝑙̃ + 2) ⋯ 𝑦(𝑁 − 1)
[ ] = 𝜃 ‫ ̃𝑙(𝑢ێ‬− 1) 𝑢(𝑙̃) ⋯ ⋮ ‫ۑ‬
𝑢(𝑙̃ + 1) 𝑢(𝑙̃ + 2) ⋯ 𝑢(𝑁 − 1) (𝑟+𝑚)𝑋 (𝑁−𝑙̃) ‫ێ‬ ‫ۑ‬
‫ێ‬ ⋮ ⋮ ⋯ ⋮ ‫ۑ‬
‫ێ‬ 𝑦(0) 𝑦(1) ⋯ 𝑦(𝑁 − 𝑙̃ − 1)‫ۑ‬
Each observation of an output ‫(𝑢 ۏ‬0) 𝑢(1) ⋯ 𝑢(𝑁 − 𝑙̃ − 1)‫𝑟(̃𝑙ے‬+𝑚) 𝑋 (𝑁−𝑙̃)
variable is regressed against past
values of all output and input
variables

The above model is fitted (via OLS) for 𝑙መ = 1,2, … , 𝑙𝑚𝑎𝑥 and AICs are noted. Here, 𝑙𝑚𝑎𝑥 is
some sufficiently large value. The lag value corresponding to the minimum AIC is then chosen.

Model order (n)


Correct selection of the value for n is important: while too large a value leads to model
overfitting, too small value for n leads to underfitting. One approach for model order selection
is based on Hankel singular values. If the plot of the singular values vs model order has a
prominent ‘elbow’, then the model order corresponding to the elbow can be chosen as shown
below
normalized singular values
𝛾/𝛾𝑚𝑎𝑥

elbow ⇒ potential model order = 3

1 2 3 4 5
model order (n)

Another practice is to choose n such that the normalized values of the (n+1)th onwards singular
values are below some threshold (SIPPY take a default value of 0.1 for this threshold).
However, very often there is no elbow or the singular values decrease slowly. Therefore, the
more extensively used criteria for model order selection is AIC67.

67
Let 𝑛̂ be a trial model order in some range 0 to n max. The outputs 𝑦̂(𝑘) are predicted using the fitted SS model and the
AIC is computed. The value of 𝑛̂ that gives minimum AIC becomes the optimal model order.
145
`

The flowchart below summarizes the aforementioned steps of CVA-based state-space model
estimation.

I/O data

Fit multivariate autoregressive lag 𝑙 Form past and future vectors, p(k) and
models for different lag values f(k), for different k

Choose lag 𝒍 that minimizes


AIC Center data

Compute covariances 𝜮𝒑𝒑 , 𝜮𝒇𝒇 , 𝜮𝒑𝒇

singular values Choose model order based on


Perform SVD [Eq. 2]
dominant singular values

or

model order n Fit several CVA models for


Get Jn and compute different model orders and
historical states x(k) choose order that minimizes AIC

Estimate matrices A, B, C, D, R, Q

State-space model
(use for multistep predictions,
control, etc.)

Figure 8.4: Complete workflow for dynamic process modeling via CVA68

68
Russell et al., Data-Driven Methods for Fault Detection and Diagnosis in Chemical Processes. Springer, 2001.
Russell et al., Fault detection in industrial processes using canonical variate analysis and dynamic principal component
analysis. Chemometrics and intelligent laboratory systems, 2000
146
`

8.3 Modeling Glass Furnaces via CVA

To demonstrate the ease of building state-space models using SIPPY, we will use data from
a glass furnace.69 The process has 3 inputs sources (two burners and one ventilator) and six
outputs (temperature sensors in a cross section of the furnace)70. The provided dataset
contains 1247 samples of the nine variables. The dataset can be downloaded from the DaISy
datasets repository. Let’s start with exploring the dataset.

# import packages
import matplotlib.pyplot as plt, numpy as np
from sklearn.preprocessing import StandardScaler
from sippy import system_identification as SysID

# read data
data = np.loadtxt('glassfurnace.dat'); U = data[:,1:4]; Y = data[:,4:]

From the above plots it is apparent that the output variables are highly correlated and therefore
the attempt to build a MIMO model is justified. We will split the dataset into training and test
datasets followed by data centering and model fitting.

# split into training and test dataset; center them


from sklearn.model_selection import train_test_split
U_train, U_test, Y_train, Y_test = train_test_split(U, Y, test_size=0.2, shuffle=False)

U_scaler = StandardScaler(with_std=False)

69
De Moor B.L.R. (ed.), DaISy: Database for the Identification of Systems, Department of Electrical Engineering,
ESAT/STADIUS, KU Leuven, Belgium, URL: http://homes.esat.kuleuven.be/~smc/daisy/
70
Overschee and Moor, N4SID*: Subspace Algorithms for the Identification of Combined Deterministic-Stochastic
Systems. Automatica, 1994
147
`

U_train_centered = U_scaler.fit_transform(U_train); U_test_centered = U_scaler.transform(U_test)


Y_scaler = StandardScaler(with_std=False)
Y_train_centered = Y_scaler.fit_transform(Y_train); Y_test_centered = Y_scaler.transform(Y_test)

# fit CVA model


model = SysID(Y_train_centered, U_train_centered, 'CVA', IC='AIC', SS_f=20, SS_orders=[1,20])

>>> The suggested order is: n= 7

Let’s interpret the above line of code used for model fitting. Here, we have specified a lag of
20 via the SS_f parameter and the Akaike information criteria is being used for optimal model
order selection. The order is constrained to be in the range of 1 to 20 as specified via the
SS_orders parameter. SIPPY returned the optimal order as seven. With the model in place,
let’s check out the model’s simulation performance to assess its acceptability.

# compare simulation responses vs measurements on training and test data


from sippy import functionsetSIM as fsetSIM
Xid_train, Yid_train_centered = fsetSIM.SS_lsim_process_form(model.A, model.B, model.C, model.D,
np.transpose(U_train_centered), model.x0) # Xid → states
Yid_train_centered = np.transpose(Yid_train_centered)

Xid_test, Yid_test_centered = fsetSIM.SS_lsim_process_form(model.A, model.B, model.C, model.D,


np.transpose(U_test_centered), Xid_train[:,-1, None]) # passing the
state at the end of training as the starting state for test data
Yid_test_centered = np.transpose(Yid_test_centered)
Training
Test

Measured Simulation

The comparison of simulation responses and measurements suggests that although the
model tends to underpredict for some instances, overall, the model does well to capture the
broad variations in the outputs.
148
`

8.4 Monitoring Industrial Chemical Plants using


CVA

In this section we will see another application of CVA. We will learn the details of CVA-based
monitoring tool development through step-by-step application for a large-scale industrial
chemical plant. The process under study is called Tennessee Eastman process (TEP) and
Figure 8.5 shows the process flowsheet. This process consists of several unit operations: a
reactor, a condenser, a separator, a stripper, and a recycle compressor. There are 22
continuous process measurements, 19 composition measurements, and 11 manipulated
variables. A dataset for this process has been made available at
https://github.com/camaramm/tennessee-eastman-profBraatz. 71 The dataset contains
training and test data from normal operation period and 21 faulty periods with distinct fault
causes. For each fault class, training dataset contains 480 samples collected over 24
operation hours and test dataset contains 960 samples collected over 48 operation hours. For
the faulty data, faulty operation starts from sample 160 onwards.

Figure 8.5: Tennessee Eastman process flowsheet72 with flow (FI), temperature (TI),
pressure (PI), composition (analyzers), level (LI), power (JI) sensors.

71
Detailed information about the process and the faults can be obtained from the original paper by Downs and Vogel
titled ‘A plant-wide industrial process control problem’
72
Adapted from the original flowsheet by Gilberto Xavier (https://github.com/gmxavier/TEP-meets-LSTM) provided
under Creative-Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/).
149
`

As alluded to before, the CVA modeling and monitoring procedures provided in this book
mirror the description in the work68 of Russell et al., and we will therefore attempt to replicate
the CVA-based fault detection results from their paper titled ‘Fault detection in industrial
processes using canonical variate analysis and dynamic principal component analysis’.
Specifically, we will use the Fault 5 dataset (file d05_te.dat) as our test data and normal
operation dataset (file d00.dat) as our training data. We will use the manipulated variables as
our inputs and the process measurements as our outputs. Our objective is to build a
monitoring tool that can accurately flag the presence of a process fault with low frequency of
false alerts. Let’s begin with a quick exploration of the dataset.

# import packages
import matplotlib.pyplot as plt, numpy as np
from sklearn.preprocessing import StandardScaler

# read data and separate input-output variables


trainingData = np.loadtxt('d00.dat').T
FaultyData = np.loadtxt('d05_te.dat')
uData_training, yData_training = trainingData[:,41:52], trainingData[:,0:22]
uData_test, yData_test = FaultyData[:,41:52], FaultyData[:,0:22]

Data has been


mean-centered

It is obvious that continuously monitoring all the 22 output (and 11 input) variables is not
practical. The single combined output plots above do seem to clearly indicate a process upset
around sample number 200 in faulty dataset; however, they also seem to give a wrong
impression of normal process conditions sample number 500 onwards. It is known that Fault
5 continues until the end of the dataset. Fortunately, CVA makes the monitoring task easy by
summarizing the state of any complex multivariate process into three simple indicators or
monitoring indices as shown in Figure 8.6. During model training, statistical thresholds are
determined for the indices and for a new data-point, the new indices’ values are compared
against the thresholds. If any of the three thresholds are violated, then presence of abnormal
process conditions is confirmed. Let’s look into how these monitoring indices are computed.

150
`

Figure 8.6: CVA-based process monitoring workflow

Process monitoring/fault detection indices


In CVA-based method, 3 indices - 𝑇𝑠2 , 𝑇𝑒2 , 𝑄 - are computed. The computation of these metrics
and their corresponding threshold are shown below. Note that the threshold expressions are
based on the assumption that process variables are gaussian distributed; if this assumption
is invalid then empirical techniques such as KDE or percentile may be employed.

𝑻𝟐𝒔 𝑻𝟐𝒆

𝑇𝑠2 (𝑘) = 𝑥 𝑇 (𝑘)𝑥(𝑘) 𝑇𝑒2 (𝑘) = 𝑝𝑇 (𝑘) 𝐽𝑒𝑇 𝐽𝑒 𝑝(𝑘) 𝑄(𝑘) = 𝑟 𝑇 (𝑘)𝑟(𝑘)
= 𝑝𝑇 (𝑘) 𝐽𝑛𝑇 𝐽𝑛 𝑝(𝑘) 𝑟(𝑘) = 𝑝(𝑘) − 𝐽𝑛𝑇 𝐽𝑛 𝑝(𝑘)

Threshold @ significance level α Threshold @ significance level α Threshold @ significance level α

2
𝑛(𝑁 2 − 1) 2
𝑧(𝑁 2 − 1) 𝜎 2𝜇2
𝑇𝑠,𝐶𝐿 = 𝐹 (𝑛, 𝑁 − 𝑛) 𝑇𝑒,𝐶𝐿 = 𝐹 (𝑧, 𝑁 − 𝑧) 𝑄𝐶𝐿 = 𝑔𝜒𝛼2 ( )
𝑁(𝑁 − 𝑛) 𝛼 𝑁(𝑁 − 𝑧) 𝛼 2𝜇 𝜎

◼ Je contains all except the first n rows of J i.e., the last 𝑙(𝑚 + 𝑟) − 𝑛 rows of J
◼ 𝑧 = 𝑙(𝑚 + 𝑟) − 𝑛
◼ Fα(n, N-n) is the 1-α percentile of the F distribution with n and N-n degrees of freedom
◼ 𝜒𝛼2 is the (1-α) percentile of a chi-squared distribution with h degrees of freedom; μ denotes the mean value
and σ denotes the variance of the Q metric
◼ Significance level of α = 0.05 would mean that there is a 5% chance that an alert is false

151
`

Let’s compute the monitoring indices for the training dataset. To ensure a better
understanding of the methodology, we will skip the usage of SIPPY package for CVA
modeling and carry out each step from scratch.

#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
## generate past (p) and future (f) vectors for training dataset and center them
#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
N = trainingData.shape[0]
l = 3 # as used by Russell et. al
m = uData_training.shape[1]
r = yData_training.shape[1]

pMatrix_train = np.zeros((N-2*l, l*(m+r)))


fMatrix_train = np.zeros((N-2*l, (l+1)*r))
for i in range(l, N-l):
pMatrix_train[i-l,:] = np.hstack((yData_training[i-l:i,:].flatten(), uData_training[i-l:i,:].flatten()))
fMatrix_train[i-l,:] = yData_training[i:i+l+1,:].flatten()

# center data
p_scaler = StandardScaler(with_std=False); pMatrix_train_centered = p_scaler.fit_transform(pMatrix_train)
f_scaler = StandardScaler(with_std=False); fMatrix_train_centered = f_scaler.fit_transform(fMatrix_train)

#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
## computes covariances and perform SVD
#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
import scipy

sigma_pp = np.cov(pMatrix_train_centered, rowvar=False)


sigma_ff = np.cov(fMatrix_train_centered, rowvar=False)
sigma_pf = np.cov(pMatrix_train_centered, fMatrix_train_centered,
rowvar=False)[:len(sigma_pp),len(sigma_pp):]

matrixProduct = np.dot(np.dot(np.linalg.inv(scipy.linalg.sqrtm(sigma_pp).real), sigma_pf),


np.linalg.inv(scipy.linalg.sqrtm(sigma_ff).real))
U, S, V = np.linalg.svd(matrixProduct)
J = np.dot(np.transpose(U), np.linalg.inv(scipy.linalg.sqrtm(sigma_pp).real))

# get the reduced order matrices


n = 29 # as used by Russell et. al
Jn = J[:n,:]
Je = J[n:,:]

152
`

#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
## get fault detection metrics for training data
#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Xn_train = np.dot(Jn, pMatrix_train_centered.T)
Ts2_train = [np.dot(Xn_train[:,i], Xn_train[:,i]) for i in range(pMatrix_train_centered.shape[0])]

Xe_train = np.dot(Je, pMatrix_train_centered.T)


Te2_train = [np.dot(Xe_train[:,i], Xe_train[:,i]) for i in range(pMatrix_train_centered.shape[0])]

r_train = pMatrix_train_centered.T - np.dot(Jn.T, Xn_train)


Q_train = [np.dot(r_train[:,i], r_train[:,i]) for i in range(pMatrix_train_centered.shape[0])]

# determine thresholds as 99th percentile of respective metrics


Ts2_CL = np.percentile(Ts2_train, 99)
Te2_CL = np.percentile(Te2_train, 99)
Q_CL = np.percentile(Q_train, 99)

Threshold

The 𝑇𝑠2 metric measures the systematic variations ‘inside’ the state space defined by the state
variables. Correspondingly, 𝑇𝑟2 quantifies the variations ‘outside’ the state space. When only
𝑇𝑠2 violates the threshold, it indicates that the state variables are ‘out-of-control’ but the
process can still be well explained by the estimated state-space model. When 𝑇𝑠2 or 𝑄 violates
the threshold, it indicates that the characteristics of noise affecting the system has changed
or the estimated model cannot explain the new faulty observations.

CVA vs PCA (or PLS) for process monitoring


You may notice the similarity between CVA-based and PCA-based
monitoring methodologies in terms of metric definitions. While dynamic PCA
(and dynamic PLS) are sometimes used to monitor dynamic processes,
several studies have shown the superiority of CVA over DPCA (and DPLS)
for dynamic process monitoring.

153
`

Fault detection
It’s time now to check whether our monitoring charts can help us detect the presence of
process abnormalities. For this, we will compute the monitoring statistics for the test data.

#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
## generate past vectors (p(k)) for test dataset and center
#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Ntest = FaultyData.shape[0]

pMatrix_test = np.zeros((Ntest-2*l, l*(m+r)))


for i in range(l,Ntest-l):
pMatrix_test[i-l,:] = np.hstack((yData_test[i-l:i,:].flatten(), uData_test[i-l:i,:].flatten()))

pMatrix_test_centered = p_scaler.transform(pMatrix_test)

#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
## get fault detection metrics for training data
#%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Xn_test = np.dot(Jn, pMatrix_test_centered.T)
Ts2_test = [np.dot(Xn_test[:,i], Xn_test[:,i]) for i in range(pMatrix_test_centered.shape[0])]

Xe_test = np.dot(Je, pMatrix_test_centered.T)


Te2_test = [np.dot(Xe_test[:,i], Xe_test[:,i]) for i in range(pMatrix_test_centered.shape[0])]

r_test = pMatrix_test_centered.T - np.dot(Jn.T, Xn_test)


Q_test = [np.dot(r_test[:,i], r_test[:,i]) for i in range(pMatrix_test_centered.shape[0])]

The control charts for the test data shows successful detection of process fault. The 𝑇𝑒2 metric
is known to be overly sensitive with high incidence of false alerts which can explain why it
seems to often breach the threshold before the onset of the actual fault. The following
flowchart summarizes all the steps for building a CVA-based monitoring tool.

154
`

Historical Real-time
I/O data I/O data

lag 𝑙 Form past and future vectors, p(k) and Form past vector p(k) lag 𝑙
f(k), for different k
O
ff
li Center data means Center p(k)
n
e O
n
Compute covariances 𝜮𝒑𝒑 , 𝜮𝒇𝒇 , 𝜮𝒑𝒇
li
M n
o e
d Perform SVD [Eq. 2]
el
M
model order n Jn , Je o
Get Jn , Je Compute metrics 𝑇𝑠2 , 𝑇𝑒2 , 𝑄 for p(k)
B n
ui it
ld o
in Compute metrics 𝑇𝑠2 , 𝑇𝑒2 , 𝑄 for each p(k) ri
g n
g
2
𝑇𝑠,𝐶𝐿 2
, 𝑇𝑒,𝐶𝐿 , 𝑄𝐶𝐿 𝑇𝑠2 > 𝑇𝑠,𝐶𝐿
2
or
2
Compute thresholds 𝑇𝑠,𝐶𝐿 , 𝑻𝟐𝒆,𝐶𝐿 , 𝑸𝐶𝐿 2 2
𝑇𝑒 > 𝑇𝑒,𝐶𝐿 or
𝑄 > 𝑄𝐶𝐿

Yes

Process Fault!!

Figure 8.7: Complete workflow for process monitoring via CVA

155
`

Equivalence of state-space and ARMAX models

Although state-space and input-output models may seem very different, they are related!
Given any state-space model, an equivalent ARMAX model can be determined and vice-
versa. Therefore, other linear structures like ARX or OE can be re-written as state-space
model as well.

Consider Consider

𝑦(𝑘) + 𝑎1 𝑦(𝑘 − 1) + ⋯ + 𝑎𝑛𝑎 𝑦(𝑘 − 𝑛) 𝑥(𝑘 + 1) = 𝐴𝑥(𝑘) + 𝐵𝑢(𝑘)


= 𝑏1 𝑢(𝑘 − 1) + ⋯ + 𝑏𝑛 𝑢(𝑘 − 𝑛) 𝑦(𝑘) = 𝐶𝑥(𝑘) +𝐷𝑢(𝑘)

equivalent using shift operator

𝑥(𝑘 + 1) = 𝐴𝑥(𝑘) + 𝐵𝑢(𝑘) 𝑞𝑥(𝑘) = 𝐴𝑥(𝑘) + 𝐵𝑢(𝑘)

𝑦(𝑘) = 𝐶𝑥(𝑘) ⇒ (𝑞𝐼 − 𝐴)𝑥(𝑘) = 𝐵𝑢(𝑘)

𝑛𝑋1 ⇒ 𝑥(𝑘) = (𝑞𝐼 − 𝐴)−1 𝐵𝑢(𝑘)


where, 𝑥(𝑘) ∈ ℝ , 𝐶 = ሾ1, 0, … , 0ሿ
⇒ 𝑦(𝑘) = ሾ𝐶(𝑞𝐼 − 𝐴)−1 𝐵 + 𝐷ሿ𝑢(𝑘)
𝑏1 −𝑎1 1 0 ⋯ 0
𝑏2 −𝑎2 0 1 ⋯ 0
𝐵= ൦ ൪, 𝐴= ൦ ൪, 𝐺(𝑞)
⋮ ⋮ ⋮ ⋮ ⋱ 1
𝑏𝑛 −𝑎𝑛 0 0 ⋯ 0

Nonetheless, we have seen in this chapter that SS model enjoys some significant
advantages vis-à-vis ARMAX models such as no requirement of a prior parametrization
(i.e., delay and orders for all the inputs need not be pre-specified) and usage of robust
SVD calculations for model fitting.

Hopefully, this chapter has sufficiently impressed upon you the powerful capabilities of CVA.
Due to its favorable properties, it is not surprising that CVA is one of the SysID methods
provided in Aspen’s DMCplus software73. With this we complete our brief foray into the world
of MIMO dynamic process modeling. Be mindful that we have only scratched the surface of
the vast literature on SIM and CVA. We hope that you have gained sufficient understanding
of how CVA works and the confidence to use it to build predictive and monitoring tools. You
now have all the tools to handle SISO and MIMO linear systems. Moving ahead, we will now

73
Chaiwatanodom, Paphonwit, Fault Detection and Identification of Large-scale Dynamical Systems. Diss. Massachusetts
Institute of Technology, 2021
156
`

relax the restriction of linearity and learn how to handle nonlinear processes in the next
chapter.

Summary

In this chapter, we looked at state-space models and saw how it offers more insights into the
internal process dynamics compared to input-output models. For fitting state-space models
we studied subspace identification techniques with the focus on CVA models. Through a
couple of industrial-scale case-studies, we learnt how to build dynamic models for usage in
process control and process monitoring. In the next chapter we will see some classical
techniques for modeling nonlinear processes.

157
`

Chapter 9
Nonlinear System Identification:
Going Beyond Linear Models

I
n the previous chapters we restricted our attention to only linear processes. However, most
industrial processes exhibit linear behavior only in a limited range of operating conditions.
If a global model of complex processes (such as high-purity distillation, pH neutralization,
polymerization, etc.) is sought, then the demon of nonlinearity would inadvertently surface. It
won’t be an exaggeration to state that nonlinearity is not an exception, rather the rule in
process industry. We won’t be surprised if you are tempted to always resort to artificial neural
networks-based structures which have become synonymous with nonlinear modeling now-a-
days. However, there exist simple classical nonlinear model structures which are more
interpretable and equally powerful. We will explore these models in this chapter.

Nonlinear models can be powerful tools but there are certain costs to their usage. These
include greater demand for variability in training data (which means more laborious
experiment design), more complex model selection procedure, and more computationally
intensive parameter estimation. Therefore, the decision to use nonlinear models should be
judiciously made. If you do decide to go ahead, then the concepts covered in this chapter may
help you greatly. Specifically, the following topics will be covered

• Introduction to NARX models


• Modeling heat exchanger process using NARX models
• Introduction to block-structured models, specifically, Hammerstein models and Wiener
models

158
`

9.1 Nonlinear System Identification: An Introduction

Nonlinear SysID becomes a necessary evil when accurate predictions are sought over wide
range of operating conditions. Although nonlinear SysID literature is not as mature as linear
SysID, SysID community has developed several useful approaches for nonlinear modeling.
Figure 9.1 shows a few popular approaches. In the 1st approach, a nonlinear relationship is
directly fitted between y(k) and past data The nonlinear form could be polynomial-based or
more complex such as neural network-based. We will focus on the polynomial form in this
chapter. Just like linear SysID, different model structures can be postulated, namely, nonlinear
ARX (NARX), NOE, NARMAX, etc. In the 2nd approach, the linear and nonlinear parts are
defined in separate blocks, leading to block-structured models. Depending upon whether the
nonlinear block comes before or after the linear block, one could have the Hammerstein model
or the Wiener model (the two most popular models from this class). In the 3rd approach,
several linear models are built for different regions of the operating space and then they are
combined to give one global model. Numerous industrial applications of these approaches
have been reported for predictive modeling, process control, and process monitoring.

Nonlinear counterparts of linear PEM Block-Structured models Local Linear models


models

past inputs 𝑤1
Nonlinear Dynamic 𝑦̂𝑚1 (𝑘)
𝑢(𝑘 − 1) … Nonlinear function
static Linear
𝑦̂(𝑘) 𝑤2 𝑦̂(𝑘)
past outputs 𝑓(𝑢(𝑘 − 1) ⋯ 𝑦̂(𝑘) 𝑢(𝑘) block block 𝑦̂𝑚2 (𝑘)
𝑦(𝑘 − 1) … 𝑦(𝑘 − 1) ⋯ 𝑓(𝑢(𝑘)) 𝐺(𝑞−1 ) ⋮
𝑦̂(𝑘 − 1) ⋯ ) 𝑤𝑀
past predictions 𝑦̂𝑚𝑀 (𝑘)
Nonlinear and linear blocks can
𝑦̂(𝑘 − 1) … be arranged differently Predictions from M linear models

Figure 9.1: Popular classical approaches for nonlinear system identification

Nonlinear transformation
Considering high computational burden of nonlinear SysID, if the nature of nonlinearity is
known beforehand, then a nonlinear transformation of the input or output variables may be
utilized to avoid explicit nonlinear fitting. Illustrations below provide some example scenarios.

𝑥𝐷 𝑇𝑖𝑛

𝑥𝑓 𝑇෨𝑜𝑢𝑡 (𝑘) = 𝑒𝑥𝑝 (−α𝑇𝑜𝑢𝑡 (𝑘))


𝑥෤𝐷 (𝑘) = log (1 − 𝑥𝐷 (k)) Transformed output
𝑇𝑜𝑢𝑡
Transformed output

High-purity distillation column Non-isothermal CSTR


(commons.wikimedia.org/wiki/File:Continuous_bach_reactor_CSTR.svg)

159
`

In practice the required nonlinear transformation is more likely to be unknown. Therefore, let’s
start with arguably the default choice for nonlinear modeling: the NARX models.

9.2 NARX Models: An Introduction

Nonlinear autoregressive with eXogenous inputs (NARX) model is, as the name suggests,
the nonlinear analogue of ARX model, wherein, the past inputs and outputs of the process
are used for future predictions. As shown in Figure 9.2, the model takes the following form

𝑦(𝑘) = 𝑓(𝑢(𝑘 − 𝑑 − 1), … , 𝑢(𝑘 − 𝑑 − 𝑛𝑏 ), 𝑦(𝑘 − 1), … , 𝑦(𝑘 − 𝑛𝑎 ), 𝜃) + 𝑒(𝑘)

model parameters

While the function f is commonly taken to be polynomial form, any other nonlinear structure
(including the neural networks) could be used as deemed suitable. A feature of polynomial
NARX is that the predictor, 𝑦̂, is linear-in-the-parameters! Therefore, polynomial NARX
parameter estimation becomes straight-forward if the specific terms/regressors (such as y(k-
1)u(k-1), u2(k-1)) that are to be included in the model is known a priori. Of course, like with
ARX, hyperparameters (d, 𝑛𝑏 , 𝑛𝑎 , polynomial degree) have to be specified.

𝑢(𝑘) 𝑢(𝑘 − 𝑑 − 1)
𝑞 −𝑑 𝑞 −1

𝑢(𝑘 − 𝑑 − 2)
𝑞 −2


𝑢(𝑘 − 𝑑 − 𝑛𝑏 ) Nonlinear
−𝑛𝑏
𝑞 function
𝑦̂(𝑘)
𝑦(𝑘) 𝑦(𝑘 − 1) 𝑓(. )
𝑞 −1

𝑦(𝑘 − 2)
𝑞 −2


𝑦(𝑘 − 𝑛𝑎 )
𝑞 −𝑛𝑎

Example: A polynomial NARX model of degree 2, d=0, and 𝑛𝑎 = 𝑛𝑏 = 1


𝑦̂(𝑘) = 𝑎1 𝑦(𝑘 − 1) + 𝑎2 𝑦 2 (𝑘 − 1) + 𝑎3 𝑦(𝑘 − 1)𝑢(𝑘 − 1) + 𝑏1 𝑢(𝑘 − 1) + 𝑏2 𝑢2 (𝑘 − 1)

Figure 9.2: NARX model structure


160
`

The primary challenge during polynomial NARX identification is model structure selection. The
number of potential regressors can become very large for even modest value of lags (na, nb)
and polynomial degree74, and inclusion of many terms increase chances of overfitting.
Fortunately, this task is automated75 using AIC-based algorithm in the Python package
SysIdentPY. Let’s see how this package can be used for nonlinear identification of an
industrial heat exchanger.

NOE and NARMAX


OE and ARMAX linear models have their nonlinear counterparts as well.

NOE model NARMAX model

𝑢(𝑘) 𝑢(𝑘) 𝑢(𝑘 − 𝑑 − 1)


𝑢(𝑘 − 𝑑 − 1) 𝑞 −𝑑 𝑞 −1
𝑞 −𝑑 𝑞 −1

⋮ ⋮
𝑢(𝑘 − 𝑑 − 𝑛𝑏 ) 𝑢(𝑘 − 𝑑 − 𝑛𝑏 )
𝑞−𝑛𝑏 𝑞−𝑛𝑏
𝑓(. ) 𝑦̂(𝑘)

𝑦̂(𝑘 − 1) 𝑦(𝑘 − 1)
𝑞 −1 𝑦(𝑘) 𝑞 −1
𝑓(. ) 𝑦̂(𝑘)

⋮ ⋮
𝑦̂(𝑘 − 𝑛𝑐 ) 𝑦(𝑘 − 𝑛𝑎 )
𝑞 −𝑛𝑐 𝑞−𝑛𝑎

𝑦̂(𝑘 − 1)
𝑞 −1

𝑦̂(𝑘) = 𝑓(𝑢(𝑘 − 𝑑 − 1), ⋯ 𝑢(𝑘 − 𝑑 − 𝑛𝑏 ),



𝑦̂(𝑘 − 1), ⋯ 𝑦̂(𝑘 − 𝑛𝑐 ), 𝜃) 𝑦̂(𝑘 − 𝑛𝑐 )
𝑞−𝑛𝑐

𝑦̂(𝑘) = 𝑓(𝑢(𝑘 − 𝑑 − 1), ⋯ 𝑢(𝑘 − 𝑑 − 𝑛𝑏 ),


𝑦(𝑘 − 1), ⋯ 𝑦(𝑘 − 𝑛𝑎 ),
𝑦̂(𝑘 − 1), ⋯ 𝑦̂(𝑘 − 𝑛𝑐 )𝜃)

74
Very often, d is kept zero and only the input and output lags (n and m) are optimized for a given polynomial degree.
75
In a recent work by Sun & Braatz (ALVEN: Algebraic learning via elastic net for static and dynamic nonlinear system
identification, Computers & Chemical Engineering, 2020), a DALVEN methodology has been proposed that uses a
combination of nonlinear transformations, univariate feature selection, and elastic net regression for NARX structure
selection.
161
`

9.3 Nonlinear Identification of a Heat Exchanger


Process Using NARX

To demonstrate the utility of nonlinear SysID, we will use data from a liquid-saturated steam
heat exchanger76 where hot saturated steam is used to heat cold liquid. The provided dataset
contains 4000 samples (sampling time 1s) of input (liquid flow rate) and output (outlet liquid
temperature) variables. For this benchmark nonlinear process, our objective will be to build
a dynamic model to predict the outlet liquid temperature as a function of incoming liquid
flowrate. The dataset can be downloaded from the DaISy datasets repository.

Hot saturated steam

Incoming cold liquid

Outgoing hot liquid

Figure 9.3: Liquid-saturated steam heat exchanger

We will use the SysIdentPy package for this nonlinear SysID exercise. Let’s begin by exploring
the dataset.

# import packages
import matplotlib.pyplot as plt, numpy as np
from sklearn.preprocessing import StandardScaler
from statsmodels.graphics.tsaplots import plot_acf
from statsmodels.tsa.stattools import ccf

76
De Moor B.L.R. (ed.), DaISy: Database for the Identification of Systems, Department of Electrical Engineering,
ESAT/STADIUS, KU Leuven, Belgium, URL: http://homes.esat.kuleuven.be/~smc/daisy/
162
`

from sysidentpy.model_structure_selection import FROLS


from sysidentpy.basis_function._basis_function import Polynomial
from sysidentpy.utils.display_results import results

# read heat-exchanger data


data = np.loadtxt(exchanger.dat')
u = data[:,1, None]; y = data[:,2, None]

plt.figure(), plt.plot(u, 'steelblue'), plt.ylabel('u(k)'), plt.xlabel('k')


plt.figure(), plt.plot(y, 'g'), plt.ylabel('y(k)'), plt.xlabel('k')

Next, we will split the dataset into training (75%) and test (25%) datasets, and center them.

# split into training and test dataset


u_fit = u[:3000,0:1]; u_test = u[3000:,0:1]
y_fit = y[:3000,0:1]; y_test = y[3000:,0:1]

u_scaler = StandardScaler(with_std=False)
u_fit_centered = u_scaler.fit_transform(u_fit); u_test_centered = u_scaler.transform(u_test)
y_scaler = StandardScaler(with_std=False)
y_fit_centered = y_scaler.fit_transform(y_fit); y_test_centered = y_scaler.transform(y_test)

To fit the polynomial NARX, we need to specify the polynomial degree and the lags. The
authors of the dataset recommend77 “a lag of 3 for the ‘AR part’ and 9 for the ‘X part’”. For
polynomial degree, a value of 2 is chosen to start with. SysIdentPY uses AIC to determine
which specific polynomial terms become part of the regressor set in the model. The following
code achieves this.

77
Bittanti and L. Piroddi, "Nonlinear identification and control of a heat exchanger: a neural network approach", Journal
of the Franklin Institute, 1996.
163
`

# fit NARX model


basis_function = Polynomial(degree=2)
model = FROLS(
order_selection=True,
n_info_values=75,
ylag=3, xlag=9,
info_criteria='aic',
estimator='least_squares',
basis_function=basis_function
)
model.fit(X=u_fit_centered, y=y_fit_centered)

A total of 57 polynomial terms are selected by SysIdentPy as part of the regressor set. The
snippet below shows some of the terms [‘x1’ to be read as ‘u’].

With the model now available, let’s start with residual analysis.

# get model (1-step ahead) predictions and residuals on training dataset


y_fit_predicted_centered = model.predict(X=u_fit_centered, y=y_fit_centered, steps_ahead=1)
y_fit_predicted = y_scaler.inverse_transform(y_fit_predicted_centered)
residuals_fit = y_fit - y_fit_predicted

164
`

doubtful
acceptable

The CCF plot is not terrible but throws some doubt on the acceptability of the model. To check
if the model can be useful, let’s check the model’s simulation response on the test dataset.

# infinite-step ahead predictions on test dataset


y_test_predicted_centered = model.predict(X=u_test_centered, y=y_test_centered, steps_ahead=None)
y_test_predicted = y_scaler.inverse_transform(y_test_predicted_centered)

plt.figure(), plt.plot(y_test, 'g', label='Measurements'), plt.plot(y_test_predicted, 'r', label='Predictions')


plt.title('Test data'), plt.ylabel('y(k): Measured vs predicted'), plt.xlabel('k'), plt.legend()
plt.figure(), plt.plot(y_test, y_test_predicted, '.')
plt.title('Test data (simulation response)'), plt.ylabel('y(k): Measured'), plt.xlabel('y(k): Predicted')

Plots below show the infinite-step ahead predictions (simulation response) for the NARX
model. For comparison, an ARX model was also generated.

NARX model ARX model

It is apparent that the model provides good simulation performance and therefore provides
confidence that the model has managed to adequately capture the deterministic relationship
165
`

of the process. Moreover, it is not surprising that the linear model struggles to capture the
relationship adequately. Polynomial degree of 2 provides reasonably good performance and
therefore, we will not optimize it any further. In a generic exercise, an optimization scheme
will need to be adopted for a more systematic optimal selection of model hyperparameters.

9.4 Introduction to Block-Structured Nonlinear


Models

Block-structured models describe nonlinear processes through separate blocks of static


nonlinearity and linear dynamics as shown in Figure 9.4. Two separate scenarios have been
depicted in the figure: the nonlinearity is at the input for a Hammerstein process while for a
Wiener process, the nonlinearity is at the output78. While this blocks-based construct may
seem very simple (and restrictive), it has been successfully used to model several complex
industrial processes. For example, an industrial scale MPC-controlled air separation plant was
modeled via Hammerstein-Wiener model using real process data by Pattison et. al. and used
for optimizing plant scheduling under varying product demands79.

u(k) y(k) u(k) y(k)


6
Valve with stiction Sensor with
issues nonlinearity

Static Linear dynamics Linear dynamics Static


Nonlinearity Nonlinearity

e(k) e(k)
𝐻(𝑞 −1 ) 𝐻(𝑞 −1 )

u(k) 𝑓(. ) w(k) y(k) u(k) 𝑓(. )


y(k)
𝐺(𝑞 −1 ) 𝐺(𝑞 −1 )

Hammerstein model Wiener model

Figure 9.4: Linear-nonlinear relationships in Hammerstein and Wiener processes

78
Other combinations of nonlinear and linear blocks (such as nonlinear-linear-nonlinear) have also been employed by
SysID community.
79
Pattison et. al., Optimal process operations in fast-changing electricity markets: framework for scheduling with low-
order dynamic models and an air separation application, Industrial & Engineering Chemistry Research, 2016
166
`

Let’s study Hammerstein model in more details to understand the general characteristics of
block-structured models.

Hammerstein model
In Hammerstein model the inputs are first transformed by a nonlinear function and then
passed through a linear dynamic process as shown in Figure 9.5. Polynomials are often used
for the nonlinear function; piecewise linear functions being another popular choice. To
understand this framework in more details, let’s derive the difference equation form for a
Hammerstein process with 2nd order polynomial and first order ARX dynamics

𝑤(𝑘) = 𝛽1 𝑢(𝑘) + 𝛽2 𝑢2 (𝑘)

𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) + 𝑏1 𝑤(𝑘)

⇒ 𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) + 𝑏1 𝛽1 𝑢(𝑘 − 1) + 𝑏1 𝛽2 𝑢2 (𝑘 − 1) eq. 1

e(k) 𝐶(𝑞−1 )
𝛽1 is often set to 1 without 𝐷(𝑞−1 )
loss of generality
v(k)

u(k) w(k) 𝐵(𝑞−1 ) y(k)


𝑓(𝑢) = 𝛽1 𝑢(𝑘) + 𝛽2 𝑢2 (𝑘) + ⋯ + 𝛽𝑚 𝑢𝑚 (𝑘)
𝐴(𝑞−1 )

𝑚
𝐵(𝑞 −1 ) 𝑟
𝐶(𝑞 −1 )
𝑦(𝑘) = ෍ 𝛽𝑟 𝑢 (𝑘) + 𝑒(𝑘)
𝐴(𝑞 −1 ) 𝐷(𝑞 −1)
𝑟=1

Figure 9.5: SISO Hammerstein model with polynomial nonlinearity. 𝛽𝑠 are parameters of the
nonlinear block.

There are different ways of estimating the parameters 𝑎1 , 𝑏1 , 𝛽1 , 𝛽2 in Eq. 1 (and, in general,
any Hammerstein model).

➢ Approach 1:

Employ a nonlinear optimization scheme to find the parameters directly

167
`

➢ Approach 2:

Redefine the parameters to derive a linear-in-the-parameters system. In Eq. 1, we can


see that the system has one parameter more than necessary. Either 𝛽1 or 𝑏1 can be
fixed to 1 without changing the relationship between u(k) and y(k). Let’s set 𝛽1 = 1 and
let 𝑏1 𝛽2 = 𝑟1. Therefore,

𝑦(𝑘) = −𝑎1 𝑦(𝑘 − 1) + 𝑏1 𝑢(𝑘 − 1) + 𝑟1 𝑢2 (𝑘 − 1) eq. 2

Eq. 2 can be fitted like a MISO ARX system (with u2(k-1) as the 2nd input to the system).
𝑟1
Once 𝑏1 and 𝑟1 are estimated, 𝛽2 is computed as .
𝑏

➢ Approach 3:

This is an iterative approach wherein the linear and nonlinear block parameters are
estimated separately at each iteration80. For our simple problem in Eq. 1, this may
seem like an overkill, but it will help understand the approach clearly

𝐼𝑛𝑖𝑡𝑖𝑎𝑙𝑖𝑧𝑒: 𝑆𝑒𝑡 𝑓(𝑢) = 𝑢

(𝑖) (𝑖)
𝐴𝑡 (𝑖 + 1)𝑡ℎ 𝑖𝑡𝑒𝑟𝑎𝑡𝑖𝑜𝑛: 𝛽1 and 𝛽2 are available from ith iteration
Step 1: (re-)estimate parameters of 𝐴(𝑞 −1 ) and 𝐵(𝑞 −1 ), i.e., 𝑎1 , 𝑏1 for a fixed
(𝑖) (𝑖)
𝑓(𝑢) = 𝛽1 𝑢(𝑘) + 𝛽2 𝑢2 (𝑘) by minimizing the following
parameters not converged

𝑁
(𝑖) (𝑖)
Continue iteration if

𝑉 = ෍ 𝑦(𝑘)−ሾ𝑎1 𝑦(𝑘 − 1) + 𝑏1 𝛽1 𝑢(𝑘 − 1) + 𝑏1 𝛽2 𝑢2 (𝑘 − 1)ሿ Linear problem


𝑘=1

Step 2: (re-)estimate parameters of 𝐴(𝑞 −1 ) and 𝑓(𝑢), i.e., 𝑎1 , 𝛽1 , 𝛽2 , for a fixed


(𝑖+1) −1
𝐵 (𝑞 −1 ) = 𝑏1 𝑞 by minimizing the following

𝑁
(𝑖+1) (𝑖+1)
𝑉 = ෍ 𝑦(𝑘)−ሾ𝑎1 𝑦(𝑘 − 1) + 𝑏1 𝛽1 𝑢(𝑘 − 1) + 𝑏1 𝛽2 𝑢2 (𝑘 − 1)ሿ Linear problem
𝑘=1

80
Y. Zhu, Multivariable System Identification for Process Control. Elsevier, 2001
168
`

Nonlinear SysID can inarguably be a daunting task for an inexperienced process modeler due
to higher complexity of parameter estimation and large number of choices that lie at a
modeler’s discretion regarding the type of nonlinearity functions to choose from. Lack of
systematic guidelines on nonlinear function selection makes things only worse. Therefore, in
this chapter we looked at a couple of intuitive nonlinear modeling frameworks that have used
for a variety of industrial processes. If linear models fail to provide satisfactory performance,
then it can be worthwhile to try these simple nonlinear models to see if any significant
improvements can be achieved. However, keep your expectations grounded - do not strive to
obtain a perfect nonlinear model at the cost of project stagnation; the approximations can be
good enough to be useful!

Summary

In this chapter we looked in detail two popular classical nonlinear SysID techniques, NARX
and Hammerstein modeling. We worked through an application of NARX for modeling heat
exchangers. With this we have completed our study of the classical modeling methods for
dynamic processes. We are confident that by now you are comfortable with system
identification jargon and can deftly handle most of the industrial dynamic modeling tasks with
the knowledge gained so far. We will continue our study of nonlinear modeling in the next part
of the book on neural networks and deep learning.

169
`

Addendum A1
Closed-Loop Identification:
Modeling Processes Under Feedback

T
he modeling techniques discussed in the book till now have an assumption regarding
independence between process inputs u(k) and disturbances v(k). In other words,
open-loop conditions were assumed. However, data collection for system identification
under open-loop condition may not always be possible due to process safety and product
quality concerns. Therefore, closed-loop identification (CLI) which refers to system
identification using data collected under feedback control becomes a necessity. However, the
feedback control leads to correlation between inputs and disturbances due to which some
open-loop techniques (such as FIR, OE, SIM, etc.) that we have discussed so far will fail to
provide unbiased models or more stringent conditions are imposed on model structure
selection for unbiased parameter estimates.

In this short addendum, we will attempt to apprise ourselves of the challenges of CLI and look
at ways to overcome these challenges. Specifically, the following topics will be covered

• Challenges with CLI


• Identifiability conditions for CLI
• Experiment design for CLI and direct identification approach

170
`

CLI Challenges

To guide our discussion on CLI challenges, consider Figure A1.1 which shows the conceptual
differences between an open loop and a closed-loop process with a linear feedback controller.

Open-loop Closed-loop
e(k) e(k)

𝐻(𝑞 −1 ) 𝐻(𝑞 −1 )

v(k) v(k)
u(k) r(k) u(k)
𝐺(𝑞−1 ) y(k) 𝐺𝑐 (𝑞−1 ) 𝐺(𝑞−1 ) y(k)

Output feedback

𝑦(𝑘) = 𝐺𝑢(𝑘) + 𝐻𝑒(𝑘)


Process model
𝑦(𝑘) = 𝐺𝑢(𝑘) + 𝐻𝑒(𝑘)

𝑢(𝑘) = 𝐺𝑐 (𝑟(𝑘) − 𝑦(𝑘)) 𝑢(𝑘) = 𝐺𝑐 (𝑟(𝑘) − 𝑦(𝑘))


𝑦(𝑘) = 𝑟(𝑘) − 𝐺𝑐−1 𝑢(𝑘)
Controller model

Figure A1.1: SISO open loop process and closed-loop process with linear controller

Let’s further assume that there is no excitation in the reference setpoints, i.e., r(k) = 0. Under
such conditions, there are two governing equations of the process which are competing for
identification as shown below

𝑦(𝑘) = 𝐺𝑝 𝑢(𝑘) + 𝐻𝑒(𝑘) process model


The two equations are
competing for identification
𝑦(𝑘) = 𝑟(𝑘) − 𝐺𝑐−1 𝑢(𝑘) = − 𝐺𝑐−1 𝑢(𝑘) controller model

Due to the presence of noise disturbances in the process model, it is the (inverse of) controller
model that will get ‘picked up’ during SysID81. Even if r(k) is externally excited, depending on
the ‘size’ of r(k) and e(k), SysID may pick 𝐺𝑝 , 𝐺𝑐−1 , or some combination of the two model.

81
Under certain conditions (such as the controller being nonlinear like MPC), it may be possible to identify Gp without
external excitation in r(k).
171
`

Data collection for CLI and Direct Identification


Approach

In closed-loop process, u(k) is decided by the controller and therefore it may not be possible
to manually induce persistent excitations in u(k). To facilitate identifiability of process model,
a common alternative is to persistently excite the reference signal r(k). If even this is not
possible then the only resort if to use the historical process data with the hope that reference
setpoints have sufficient variability.

e(k)
r(k)
𝐻(𝑞 −1 )

v(k)
r(k) −1
u(k) −1
𝐺𝑐 (𝑞 ) 𝐺(𝑞 ) y(k)

Output feedback

Figure A1.2: Closed-loop process with persistently excited reference signal

When the closed-loop process is excited externally through r(k), the common CLI approach
(called direct identification approach) directly builds a model between y(k) and u(k) (just like
we did for open-loop systems) without utilizing any information about the controller or the
reference signals.

Model structure selection for CLI


Assuming sufficiently excited r(k), PEM models provide unbiased
models with closed-loop data if both G(q-1) and H(q-1) are correctly
chosen. Note that the correct noise model structure was not a necessity
for open-loop case.

172
`

Part 3
Artificial Neural Networks & Deep Learning

173
`

Chapter 10
Artificial Neural Networks:
Handling Complex Nonlinear Systems

t won’t be an exaggeration to say that artificial neural networks (ANNs) are currently the

I most powerful modeling construct for describing generic nonlinear processes. ANNs can
capture any kind of complex nonlinearities, don’t impose any specific process
characteristics, and don’t demand specification of process insights prior to model fitting.
Furthermore, several recent technical breakthroughs and computational advancements have
enabled (deep) ANNs to provide remarkable results for a wide range of problems.
Correspondingly, ANNs have re(caught) the fascination of data scientists and the process
industry is witnessing a surge in successful applications of ML-based process control,
predictive maintenance, and inferential modeling involving ANN-based system identification.

For SysID, ANNs are commonly used in NARX framework wherein an ANN model is fitted to
find the nonlinear relationship between current output and past input/output measurements.
In such applications, the FFNN (feed-forward neural networks) is invariably employed.
However, for dynamic modeling, a specialized type of network called RNN (recurrent neural
network) exist which is designed to be aware of the temporal nature of dynamic process data.
Consequently, RNNs tend to be more parsimonious than FFNN. We will see SysID
applications of both these popular architectures in this chapter.

There is no doubt that ANNs have proven to be monstrously powerful. However, it is not easy
to tame this monster. If the model hyperparameters are not set judiciously, it is very easy to
end up with disappointing results. The reader is referred to Part 3 of Book 1 of this series for
a detailed exposition on ANN training strategies and different facets of ANN models. In this
chapter, SysID relevant concepts are sufficiently described to enable an uninitiated reader to
learn how to use ANNs. Specifically, the following topics are covered
• Introduction to ANN, FFNN, RNN, LSTM
• Heat exchanger SysID via FFNN-based NARX
• Heat exchanger SysID via LSTM

174
`

10.1 ANN: An Introduction

Artificial neural networks (ANNs) are nonlinear empirical models which can capture complex
relationships between input-output variables via supervised learning or recognize data
patterns via unsupervised learning. Architecturally, ANNs were inspired by human brain and
are a complex network of interconnected neurons as shown in Figure 10.1. An ANN consists
of an input layer, a series of hidden layers, and an output layer. The basic unit of the network,
neuron, accepts a vector of inputs from the source input layer or the previous layer of the
network, takes a weighted sum of the inputs, and then performs a nonlinear transformation to
produce a single real-valued output. Each hidden layer can contain any number of neurons.

Single Neuron

Nonlinear mapping
f(.)

Figure 10.1: Architecture of a single neuron and feedforward neural network with 2 hidden layers
for a SISO (single input single output) process within NARX framework

The network shown in Figure 10.1 is an example of a fully-connected feed-forward neural


network (FFNN), the most common type of ANN. In FFNN, signals flow in only one direction,
from the input layer to the output layer via hidden layers. Neurons between consecutive layers
are connected fully pairwise and neurons within a layer are not connected.

What is deep learning


In a nutshell, using an ANN with a large number of hidden layers to find
relationship/pattern in data is deep learning (technically, ≥ 2 hidden
layers implies a deep neural network (DNN)). Several recent algorithmic
innovations have overcome the model training issues for DNNs which
have resulted in the DNN-led AI revolution we are witnessing today.
175
`

10.2 Modeling Heat Exchangers using FFNN-


NARX

To learn how to setup and fit a feed-forward neural network, we will reuse the heat-exchanger
dataset from Chapter 9 and build a FFNN-NARX model between the incoming liquid flow and
outgoing liquid temperature. The code for importing basic packages and loading data into the
workspace remains the same.

# split dataset into fitting and test dataset


u_fit = u[:3000, 0:1]; u_test = u[3000:,0:1]
y_fit = y[:3000, 0:1]; y_test = y[3000:, 0:1]

# scale data before model fitting


u_scaler = StandardScaler()
u_fit_scaled = u_scaler.fit_transform(u_fit); u_test_scaled = u_scaler.transform(u_test)
y_scaler = StandardScaler()
y_fit_scaled = y_scaler.fit_transform(y_fit); y_test_scaled = y_scaler.transform(y_test)

As shown in Figure 10.1, the input vector that gets supplied to the network for y(k)’s prediction
includes all the lagged variables. Therefore, we need to now create the augmented input
variables.

# rearrange u and y data into (# observation samples, # lagged regressors) form


u_lags = 9; y_lags = 3
u_augument_fit_scaled = []
y_augment_fit_scaled = []

for sample in range(max(u_lags, y_lags), u_fit.shape[0]):


row = np.hstack((u_fit_scaled[sample-u_lags:sample,0], y_fit_scaled[sample-y_lags:sample,0]))
u_augument_fit_scaled.append(row)
y_augment_fit_scaled.append(y_fit_scaled[sample])

# conversion: convert list into array


u_augument_fit_scaled = np.array(u_augument_fit_scaled)
y_augment_fit_scaled = np.array(y_augment_fit_scaled)

We are now ready to define and fit our neural network.

# import Keras libraries


from tensorflow.keras import Sequential
from tensorflow.keras.layers import Dense
176
`

# define model
model = Sequential()
model.add(Dense(14, activation='relu', kernel_initializer='he_normal', input_shape=(12,)))
# 14 neurons in 1st hidden layer; this hidden layer accepts data from a 12-dimensional input
model.add(Dense(7, activation='relu', kernel_initializer='he_normal'))
# 7 neurons in 2nd layer
model.add(Dense(1)) # output layer

# compile and fit model


model.compile(loss='mse', optimizer='Adam') # mean-squared error is to be minimized
model.fit(u_augument_fit_scaled, y_augment_fit_scaled, epochs=250, batch_size=125)

Let’s now get the model predictions and residuals on the training dataset and see how our
residuals look like.

# get model (1-step ahead) predictions and residuals on training dataset


y_augment_fit_scaled_pred = model.predict(u_augument_fit_scaled)
y_augment_fit_pred = y_scaler.inverse_transform(y_augment_fit_scaled_pred)
y_augment_fit = y_scaler.inverse_transform(y_augment_fit_scaled)
residuals_fit = y_augment_fit - y_augment_fit_pred

doubtful
acceptable

Results are similar to that seen for polynomial-NARX model. The slight breaches of the
confidence interval in CCF plot indicates the need to add more lagged variables as model
inputs. However, as a modeler, you have to make a judgement between making the model
177
`

more complex versus assessing the acceptability of slight model inaccuracies. To check if the
model can be useful, let’s again check the model’s simulation response on the test dataset.
We first need to arrange our test data in appropriate form.

# rearrange u and y data into (# sequence samples, # lagged regressors) form


u_augument_test_scaled = []
y_augment_test_scaled = []

for sample in range(max(u_lags, y_lags), u_test.shape[0]):


row = np.hstack((u_test_scaled[sample-u_lags:sample,0], y_test_scaled[sample-y_lags:sample,0]))
u_augument_test_scaled.append(row)
y_augment_test_scaled.append(y_test_scaled[sample])

# conversion: convert list into array


u_augument_test_scaled = np.array(u_augument_test_scaled)
y_augment_test_scaled = np.array(y_augment_test_scaled)

While generating the 1-step ahead predictions on validation dataset is straightforward, the
code below shows how to generate simulation response or the infinite-step ahead predictions.
It is easy to see that we are simply using the past model predictions to generate subsequent
predictions.

# infinite-step ahead predictions on test dataset [first u_lags samples are used as initial conditions]
y_augment_test_scaled_sim = np.copy(y_test_scaled)

for sample in range(u_lags, len(u_test),1):


regressorVector = np.hstack((u_test_scaled[sample-u_lags:sample,0],
y_augment_test_scaled_sim[sample-y_lags:sample,0]))
regressorVector = regressorVector[None,:]
sim_response = model.predict(regressorVector)
y_augment_test_scaled_sim[sample] = sim_response

y_augment_test_sim = y_scaler.inverse_transform(y_augment_test_scaled_sim)

Plots below show the 1-step ahead and the infinite-step ahead predictions (simulation
response) for the FFNN-NARX model.

178
`

1-step ahead Infinite-step ahead

By now we are informed enough to not get very excited with good 1-step ahead predictions.
However, it is encouraging to see the good simulation response, which although not as good
as 1-step ahead predictions82, is able to match the ups and downs in the raw measurements.

82
You may notice some minor variations between your results and those shown in this chapter due to random nature of
network fitting algorithm.
179
`

Understanding flow of data in a FFNN


If you execute the command model.summary() for the model developed in the previous
section, you will be presented with the following information which details the number of
parameters to be estimated in each layer of the network. Let’s understand how these
numbers are obtained which will help clarify the flow of information in FFNN.

We know that each augmented input sample is 12-dimensional (𝑢𝑎𝑢𝑔 ∈ 𝑅12). In the
forward pass (also called forward propagation), the augmented input is first processed
by the neurons of the first hidden layer. In the jth neuron of this layer, the weighted sum
of the inputs are non-linearly transformed via an activation function, g

𝑎𝑗 = 𝑔(𝑤𝑗𝑇 𝑢𝑎𝑢𝑔 + 𝑏𝑗 )

𝑤𝑗 ∈ 𝑅12 are the weights applied to the inputs and 𝑏𝑗 is the bias added to the sum. Thus,
each neuron has 13 parameters (12 weights and a bias) leading to 182 parameters for
all the 14 neurons of the 1st layer that need to be estimated. Outputs of all the 14 neurons
form vector 𝑎(1) ∈ 𝑅14
𝑎(1) = 𝑔(1) (𝑊 (1) 𝑢𝑎𝑢𝑔 + 𝑏 (1) )

where each row of 𝑊 (1) ∈ 𝑅14×12 contains the weights of a neuron. The same activation
function is used by all the neurons of a layer. 𝑎(1) becomes the input to the 2nd hidden
layer.
𝑎(2) ∈ 𝑅 7 = 𝑔(2) (𝑊 (2) 𝑎(1) + 𝑏 (2) )

where 𝑊 (2) ∈ 𝑅 7×14 . Each neuron in the 2nd layer has 14 weights and a bias parameter,
leading to 105 parameters in the layer. The final output layer had a single neuron with 8
parameters and no activation function, giving the network output as follows

𝑎 (3) = 𝑦̂ = (𝑤 (3) )𝑇 𝑎(2) + 𝑏 (3)

where 𝑤 (3) ∈ 𝑅 7 .

180
`

10.3 RNN: An Introduction

Recurrent neural networks (RNNs) are ANNs for dealing with sequential data, where the order
of occurrence of data holds significance. In the FFNN-based NARX model that we studied in
the previous section, there is no implicit or explicit specification of the fact that the data is
temporal/sequential in nature, i.e., u(k-2) comes before u(k-1) for example. There is no
efficient mechanism to specify this temporal order of data in a FFNN. RNNs accomplish this
by processing elements of a sequence recurrently and storing a hidden state that summarizes
the past information during the processing. The basic unit in a RNN is called a RNN cell which
simply contains a layer of neurons. Figure 10.2 shows the architecture of a RNN consisting of
a single cell and how it processes a data sequence with ten samples.

Figure 10.2: Representation of an RNN cell in rolled and unrolled format. The feedback
signal in rolled format denotes the recurrent nature of the cell. Here, the hidden state (h) is
assumed to be same as intermediate output (y). h(0) is usually taken as zero vector.

We can see that the ten samples are processed in the same order of their occurrence and not
at once. An output, y(i), is generated at the ith step and then fed to the next step for processing
along with x(i+1). By way of this arrangement, y(i+1) is a function of x(i+1) and y(i). Since, y(i) itself
is a function of x(i) and y(i-1), y(i+1) effectively becomes a function of x(i+1), x(i), and y(i-1). Continuing
the logic further implies that the final sequence output, y(10), is a function of all ten inputs of
the sequence, that is, x(10), x(9),…, x(1). This ‘recurrent’ mechanism leads to efficient capturing of
temporal patterns in data.

181
`

RNN outputs

If the neural layer in the RNN cell in Figure 10.2 contains n neurons (n equals 4 in the shown
figure), then each y(i) or h(i) is a n-dimensional vector. For simple RNN cells, y(i) equals h(i). Let
x be a m-dimensional vector. At any ith step, we can write the following relationship

𝑦(𝑖) = 𝑔(𝑊𝑥 𝑥(𝑖) + 𝑊𝑦 𝑦(𝑖−1) + 𝑏)

where 𝑊𝑥 ∈ 𝑅 𝑛×𝑚 with each row containing the weight parameters of a neuron as applied to
x vector, 𝑊𝑦 ∈ 𝑅 𝑛×𝑛 with each row containing the weight parameters of a neuron as applied
to y vector, 𝑏 ∈ 𝑅 𝑛 contains the bias parameters, and 𝑔 denotes the activation function. The
same neural parameters are used at each step.

If all the outputs of the sequence are of interest, then it is called sequence-to-sequence or
many-to-many network. However, very often only the last step output is needed, leading to
sequence-to-vector or many-to-one network. Moreover, the last step output may need to be
further processed and so a FC layer is often added. Figure 10.3 shows one such topology.

Figure 10.3: Sequence to vector RNN topology with a FC layer

RNN-based NARX topology

Figure 10.4 below shows how a potential RNN-based NARX architecture may look like for a
SISO process where three lagged measurements are used to make one-step ahead
predictions. We can observe that all the lagged measurements are not processed
simultaneously by an RNN cell which often results in less number of model parameters when
compared to a FFNN-based NARX model.

182
`

Shallow RNN-NARX
𝑢(𝑘)
where 𝑥(𝑘) = [ ]
𝑦(𝑘)

Figure 10.4: RNN-NARX topology for a SISO process. [Note that if the model input vectors
(x) are simply the process inputs (u) then the architecture becomes NFIR (nonlinear FIR)].

LSTM networks

RNNs are powerful dynamic models, however, the vanilla RNN (with a single neural layer in
a cell) introduced before faces difficulty learning long-term dependencies, i.e., when number
of steps in a sequence is large (~ ≥10). This happens due to the vanishing gradient problem
during gradient backpropagation. To overcome this issue, LSTM (Long Short-Term Memory)
cells have been devised which are able to learn very long-term dependencies (even greater
than 1000) with ease. Unlike vanilla RNN cells, LSTM cells have 4 separate neural layers as
shown in Figure 10.5. Moreover, in a LSTM cell, the internal state is stored in two separate
vectors, h(t) or hidden state and c(t) or cell state. Both these states are passed from one LSTM
cell to the next during sequence processing. h(t) can be thought of as the short-term
state/memory and c(t) as the long-term state/memory (we will see later why), and hence the
name LSTM.

The vector outputs of the FC layers interact with each-other and the long-term state via three
‘gates’ where element-wise multiplications occur. These gates control what information go
into the long-term and short-term states at any sequence processing step. While we will
understand the mathematical details later, for now, if suffices to know the following about
these gates:

• Forget gate determines what parts of long-term state, c(t), are retained and erased
• Input gate determines what parts of new information (obtained from processing of x(t) and
h(t-1)) are stored in long-term state
• Output gate determines what parts of long-term state are passed on as short-term state

183
`

Figure 10.5: Architecture of an LSTM cell. Three FC layers use sigmoid activation functions
and one FC layer uses tanh activation function. Each of these neural layers have its own
parameters 𝑊𝑥 , 𝑊ℎ , and 𝑏

This flexibility in being able to manipulate what information are passed down the chain during
sequence processing is what makes LSTM networks so successful at capturing long-term
patterns in sequential datasets. Consequently, LSTM networks are the default RNNs now-a-
days. In the next section we will see a quick application of RNN for system identification using
LSTM cells.

184
`

Vanilla RNN cell vs GRU cell vs LSTM cell

There is another popular variant of RNN cell, called GRU cell. As shown in the illustration
below, GRU cell is simpler than LSTM cell. GRU cell has 3 neural layers and its internal
state is represented using a single vector, h(t). For several common tasks, GRU cell-
based RNN seems to provide similar performance as LSTM cell-based RNN and
therefore, it is slowly gaining more popularity.

10.4 Modeling Heat Exchangers using LSTM

To show how to train a LSTM network, we will re-use the heat-exchanger dataset. We will
also use early stopping to optimize the number of epochs using validation dataset.

# read data
u_fit = u[:3000,0:1]; u_val = u[3000:,0:1]
y_fit = y[:3000,0:1]; y_val = y[3000:,0:1]

# scale data before model fitting


u_scaler = StandardScaler()
u_fit_scaled = u_scaler.fit_transform(u_fit); u_val_scaled = u_scaler.transform(u_val)
y_scaler = StandardScaler()
y_fit_scaled = y_scaler.fit_transform(y_fit); y_val_scaled = y_scaler.transform(y_val)

X_fit_scaled = np.hstack((u_fit_scaled, y_fit_scaled)) # @ Figure 10.4


X_val_scaled = np.hstack((u_val_scaled, y_val_scaled))

185
`

As shown in Figure 10.4, the input that gets supplied to the network for y(k)’s prediction is a
sequence of the lagged measurements. Therefore, we need to now create these sequences.
Currently, the shape of X array is {# of samples, # of features}. For RNN, this input data matrix
needs to be converted into the shape {# of sequence samples, # of time steps, # of features}
such that each entry (of shape {# of time steps, # of features}) along the 0th dimension is a
complete sequence of past data which is used to make prediction of temperature values.
Here, the # of time steps is taken to be 9 and # of features equals 2.

# rearrange X data into (# sequence samples, # time steps, # features) form


nTimeSteps = 9
X_fit_scaled_sequence = []; X_val_scaled_sequence = []
y_fit_scaled_sequence = []; y_val_scaled_sequence = []

for sample in range(nTimeSteps, X_fit_scaled.shape[0]):


X_fit_scaled_sequence.append(X_fit_scaled[sample-nTimeSteps:sample, :])
y_fit_scaled_sequence.append(y_fit_scaled[sample])

for sample in range(nTimeSteps, X_val_scaled.shape[0]):


X_val_scaled_sequence.append(X_val_scaled[sample-nTimeSteps:sample, :])
y_val_scaled_sequence.append(y_val_scaled[sample])

# convert list of (time steps, features) arrays into (samples, time steps, features) array
X_fit_scaled_sequence, y_fit_scaled_sequence = np.array(X_fit_scaled_sequence),
np.array(y_fit_scaled_sequence)
X_val_scaled_sequence, y_val_scaled_sequence = np.array(X_val_scaled_sequence),
np.array(y_val_scaled_sequence)

Basically, each block of 9 continuous rows in (scaled) X array becomes a sequence. The
topology of RNN that we will build is same as that shown in Figure 10.4, except for the number
of time-steps. Like we did for FFNN modeling, we will import relevant Keras libraries. In the
code below, a LSTM RNN layer is followed by a dense layer.

# import Keras libraries


from tensorflow.keras import Sequential
from tensorflow.keras.layers import LSTM
from tensorflow.keras.layers import Dense
from tensorflow.keras import regularizers

# define model
model = Sequential()
model.add(LSTM(units=6, kernel_regularizer=regularizers.L1(0.001), input_shape=(nTimeSteps,2)))
# LSTM cell with 6 neurons in each of the 4 neural layers
model.add(Dense(units=1))
# 1 neuron in output layer
186
`

The above 3-line code completely defines the structure of the required RNN. The single
neuron in the output layer does the job of transforming the 6th dimensional hidden state vector
from the last step of RNN layer into a scalar value. The model summary below shows the
number of model parameters in each layer.

In vanilla RNN cell, we saw that 𝑊𝑥 ∈ 𝑅𝑛×𝑚 , 𝑊ℎ ∈ 𝑅𝑛×𝑛 and, 𝑏 ∈ 𝑅𝑛 . This leads to total
number of parameters equal to 𝑚𝑛 + 𝑛2 + 𝑛. In an LSTM cell, each of the 4 neural layers
have their own set of these parameters. Therefore an LSTM cell has 4(𝑚𝑛 + 𝑛2 + 𝑛)
model parameters. In this example, we have m = 2 and n = 6; therefore we ended up
with 4(12 + 36 + 6) = 216 model parameters in the LSTM layer.

Next we compile and fit the model.

# compile and fit model with early stopping


from tensorflow.keras.callbacks import EarlyStopping

model.compile(loss='mse', optimizer='Adam')
es = EarlyStopping(monitor='val_loss', patience=10, restore_best_weights=True)
history = model.fit(X_fit_scaled_sequence, y_fit_scaled_sequence, epochs=250, batch_size=125,
validation_data=(X_val_scaled_sequence, y_val_scaled_sequence), callbacks=[es])

Let’s now get the model predictions and residuals on the fitting dataset and see how our
residuals look like.

# get model (1-step ahead) predictions and residuals on fitting dataset


y_fit_scaled_sequence_pred = model.predict(X_fit_scaled_sequence)
y_fit_sequence_pred = y_scaler.inverse_transform(y_fit_scaled_sequence_pred)
y_fit_sequence = y_scaler.inverse_transform(y_fit_scaled_sequence)
residuals_fit = y_fit_sequence - y_fit_sequence_pred

187
`

Results are similar to that seen for FFNN-NARX model. Let us now check its performance on
validation dataset. We again pay emphasis to the infinite-step ahead predictions.

# infinite-step ahead predictions [first nTimeSteps samples are used as initial conditions]
y_val_scaled_sim = np.copy(y_val_scaled)

for sample in range(nTimeSteps, X_val_scaled.shape[0]):


X_val_scaled_sim = np.hstack((u_val_scaled, y_val_scaled_sim))
inputSequence = X_val_scaled_sim[sample-nTimeSteps:sample, :]
inputSequence = inputSequence[None,:,:]
sim_response = model.predict(inputSequence)
y_val_scaled_sim[sample] = sim_response

y_val_pred_sim = y_scaler.inverse_transform(y_val_scaled_sim)

Plots below show the 1-step ahead and the infinite-step ahead predictions (simulation
response) for the LSTM-NARX model.

188
`

1-step ahead Infinite-step ahead

Ideally, we should check the predictions on a dataset completely separate from fitting and
validation datasets; but we are checking it on validation dataset in the current case-study just
to be consistent with the assessment dataset used for FFNN-NARX and polynomial-NARX
(from Chapter 9).

This concludes our quick peep into the world of artificial neural networks. We are guilty of
condensing a lot of concepts into a single chapter. However, you should hopefully now be
comfortable developing ANN-based solutions for your nonlinear SysID needs. Do keep in
mind that we only barely scratched the surface of the vast field of ANNs. Nonetheless, you
should be able to navigate the ANN literature comfortably now and build upon the knowledge
you have gained in this chapter.

Summary

In this chapter we studied the application of ANNs for dynamic systems. We first looked at
how to build FFNN-based NARX models and saw its application for heat-exchanger modeling.
Then, we learnt the remarkable capabilities of LSTM networks in handling temporal data. After
working out these examples, you would have gained a very good understanding on how to
setup the ANN-based solution for your specific problems. With this we will sign-off now and
wish you all the best in your ML journey.
189
`

End of the book

190
`

By the process data scientists, for the process data scientists, of process data science

Machine Learning in Python for Dynamic Process Systems

This book is designed to help readers gain a working-level knowledge of machine


learning-based modeling techniques for dynamic processes. Readers can leverage
the concepts learned to build advanced solutions for process monitoring, soft sensing,
predictive maintenance, and process control for dynamic systems. The application-
focused approach of the book is reader friendly and easily digestible to the practicing
and aspiring process engineers, and data scientists. Upon completion, readers will be
able to confidently navigate the system identification literature and make judicious
selection of modeling approaches suitable for their problems.

The following topics are broadly covered:


• Exploratory analysis of dynamic dataset
• Best practices for dynamic modeling
• Linear and discrete-time classical parametric and non-parametric models
• State-space models for MIMO systems
• Nonlinear system identification and closed-loop identification
• Neural networks-based dynamic process modeling