Anchor Bolt Design

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

TITLE:Anchor bolt design start of staircase

JOB NO. 23021


Made by Nadir DOC NO. AB140–SD-DD-004
ANCHOR BOLTS DESIGN REPORT SHEET NO. Page 200 of 205
REV NO. 0

BASE PLATE & ANCHOR BOLT DESIGN FOR SUPPORT TYPE 02B( PIPE 168.3)

LOADING DETAILS
Considering three critical loading combinations from STAAD
Case (i) : Max. vertical load and corresponding shear & moments
Case (ii) : Max. moment and correspong force & shear
Case (i) : Min. vertical load (or) Max.tension and correspondng shear & moments

FY Fx kN Fz kN Mx Mz
kN kNm kNm
Case (i) -63 42 -4 66 353
Case (ii) 12 25 5 12
Case (iii) 12 25 5 12

SECTION DETAILS
Assumed Section = PIPE 508
Depth D = 450 mm
Width B = 450 mm

BASE PLATE DETAILS


Length Lp = 400 mm
Width Bp = 400 mm
Thickness Tp = 32 mm
Strength of plate pyp 275 N/mm2

ANCHOR BOLT DETAILS


Type of bolt = M24
Anchor bolt dia ø = 24 mm
Number of bolts n = 10
Tensile area of bolt At = 361.9 mm2
Tension capacity of bolt Pnom = 88.6 kN
Shear capacity of bolt Ps = 11.07 kN
Edge distance provided e = 50 mm
Embedded length of bolt La = 750 mm
TITLE:Anchor bolt design start of staircase
JOB NO. 23021
Made by Nadir DOC NO. AB140–SD-DD-004
ANCHOR BOLTS DESIGN REPORT SHEET NO. Page 200 of 205
REV NO. 0
CONCRETE DETAILS
Grade of concrete = C40
Characteristic compressive strength fcu = 40 N/mm2
Bond coefficient β = 0.3 (BS8110:1997 Table 3.26)
Permissible bearing pressure on conrete wp = 06*fcu
= 24 N/mm2

CHECK FOR BEARING PRESSURE ON CONCRETE


Maximum pressure on concrete = (P/A)+(Mx/Zx)+(Mz/Zz)
= 38.8875 N/mm2
> wp UNSAFE

CHECK FOR THICKNESS OF BASE PLATE


Maximum base pressure wp = 38.8875 N/mm2
By assuming constant pressure max. BM = 4.8609375 kNm
Assumed thickness of base plate Tp = 32 mm
Plate modulus Z = 68267 mm3
Moment capacity Mc = 1.5*pyp*z
= 28.2 kNm
> Max. BM SAFE

CHECK FOR TENSION IN BOLTS


Moment causing tension on bolts along Z directio = 153 kNm
Lever arm = 150 mm
Direct tension on bolts = 8 kN
Number of bolts in tension side = 7
Push pull force = 1020 kN
Total tension on each bolts = 146.51428571429 kN
> Pnom UNSAFE

Moment causing tension on bolts along X directio = 66.00 kNm


Lever arm = 150 mm
Direct tension on bolts = 12 kN
Number of bolts in tension side = 7
Push pull force = 440 kN
Total tension on each bolts = 64.057142857143
< Pnom SAFE

CHECK FOR SHEAR IN BOLTS


Resultant shear Fs = 42.190046219458 kN
Shear on each bolts = 21.095023109729 kN
> Ps UNSAFE

CHECK FOR COMBINED SHEAR AND TENSION

(Fs/Ps) + (Ft/Pnom) < 1.4 (BS5950:2000 Cl. 6.3.4.4)


= 3.56
> 1.4 UNSAFE
TITLE:Anchor bolt design start of staircase
JOB NO. 23021
Made by Nadir DOC NO. AB140–SD-DD-004
ANCHOR BOLTS DESIGN REPORT SHEET NO. Page 200 of 205
REV NO. 0
TITLE:Anchor bolt design start of staircase
JOB NO. 23021
Made by Nadir DOC NO. AB140–SD-DD-004
ANCHOR BOLTS DESIGN REPORT SHEET NO. Page 200 of 205
REV NO. 0
CHECK FOR EMBEDDED LENGTH OF ANCHOR BOLT
Design ultimate ahcnorage bond stress fbu = β(fcu)^1/2 (BS8110:1997 Cl. 3.12.8.4)
= 1.897366596101
Maximum tension on each bolts Ft = 146.51428571429 kN
Embedded length required Lreq = Ft/(fbu*PI()*ø)
= 1024.1595225072 mm
Provided embedded length of bolt La = 750 mm
< Lreq UNSAFE
CHECK FOR WELD BETWEEN SECTION & BASE PLATE
Available length of weld Lw = 508 mm
Design strength of weld pw = 220 N/mm2
Size of weld s = 6 mm
Shear capacity of weld Sw = 0.7*s*pw*Lw
= 469.392 kN
Actual shear force on weld Fs = 42.190046219458 kN
< Sw SAFE