Poweredge r660 Technical Guide
Poweredge r660 Technical Guide
Technical Guide
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its
subsidiaries. Other trademarks may be trademarks of their respective owners.
Contents
Chapter 4: Processor................................................................................................................... 13
Processor features ........................................................................................................................................................... 13
Supported processors................................................................................................................................................. 13
Chapter 6: Storage...................................................................................................................... 16
Storage controllers............................................................................................................................................................ 16
Supported Drives............................................................................................................................................................... 16
Internal storage configuration......................................................................................................................................... 17
External Storage.................................................................................................................................................................17
Chapter 7: Networking.................................................................................................................18
Overview.............................................................................................................................................................................. 18
OCP 3.0 support................................................................................................................................................................ 18
Supported OCP cards................................................................................................................................................. 18
Contents 3
Chapter 10: Rack, rails, and cable management........................................................................... 36
Rails and cable management information....................................................................................................................36
4 Contents
1
System overview
The PowerEdge R660 system is a 1U server that supports:
The system features:
● Up to two 4 th Generation Intel Xeon Scalable processors with up to 56 cores and optional Intel ® QuickAssist Technology
● Up to 32 RDIMMs with up to 8 TB of memory and speed up to 4800 MT/s
● Optional Direct Liquid Cooling
● Two redundant AC or DC power supply units
● Up to 10 x 2.5-inch or 8 x 2.5-inch SATA/SAS/NVMe (HDD/SSD) drives
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe
PCIe SSD User's Guide at https://www.dell.com/support > Browse all Products > Data Center Infrastructure >
Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals
and Documents.
NOTE: All instances of SAS, SATA drives are referred to as drives in this document, unless specified otherwise.
Topics:
• Key workloads
• New technologies
Key workloads
The versatile R660 is designed to address data-intensive, diverse workloads including:
● High Density Virtualization
● Dense Database Analytics(VDI)
● Mixed Workload Standardization
New technologies
The table lists the new technologies that are featured on R660.
System overview 5
Table 1. New technologies (continued)
Technology Detailed Description
Rear I/O with:
● 1 x Dedicated iDRAC Ethernet port
● 1 x USB 3.0
● 1 x USB 2.0
● 1 x VGA port (optional for liquid cooling configuration)
Serial Port Option with STD RIO board
OCP Mezz 3.0 (supported by x8 PCIe lanes)
Front I/O with:
● 1 x Dedicated iDRAC Direct micro-USB
● 1 x USB 2.0
● 1 x VGA port
CPLD 1-wire Support payload data of Front PERC, Riser, BP, and Rear I/O
to BOSS-N1 and iDRAC.
Dedicated PERC Front Storage module PERC with Front PERC11 & PERC12
Software RAID OS RAID/S160
Power Supplies 60 mm dimension is the new PSU form factor with 15G on 16G
design.
Titanium 700 W AC/HVDC
Platinum 800 W AC/HVDC
Titanium 1100 W AC/HVDC
Platinum 1400 W AC/HVDC
1100 W LVDC -48- -60 VDC
Titanium 1800 W AC/HVDC
6 System overview
2
System features and generational
comparison
The following table shows the comparison between the PowerEdge R660 with the PowerEdge R650.
GPU Options Up to 3 x 75 W SW Up to 3 x 75 W SW
Chassis views
Figure 4. Rear view of the R660 with 2x 2.5 inches Storage drives, 1x LP
Topics:
• Processor features
Processor features
The Intel 4 th Generation Xeon ® Scalable Processors stack is the next generation data center processor offering with significant
performance increases, integrated acceleration, and next generation memory and I/O. Sapphire Rapids accelerate customer
usages with unique workload optimizations.
The following lists the features and functions that are in the upcoming 4 th Generation Intel ® Xeon Scalable Processor offering:
● Faster UPI with up to four Intel Ultra Path Interconnect (Intel UPI) at up to 16 GT/s, increasing multisocket bandwidth
● More, faster I/O with PCI Express 5 and up to 80 lanes (per socket)
● Enhanced Memory Performance with DDR5 support and memory speed up to 4800 MT/s in one DIMM per channel (1DPC)
and 4400 MT/s in two DIMM per channel (2DPC)
● New built-in accelerators for data analytics, networking, storage, crypto, and data compression
Supported processors
The following table shows the Intel Sapphire Rapids SKUs that are supported on the R660.
Processor 13
NOTE: *8470Q and 6458Q are supported only in liquid cooling configuration.
NOTE: Mixing of the processors are not recommended. If a liquid cooled processor is installed in one socket, then the
second processor used must be of the same type.
14 Processor
5
Memory subsystem
Topics:
• Supported memory
Supported memory
Table 4. Memory technology comparison
Feature PowerEdge R660 (DDR5)
DIMM type RDIMM
Transfer speed 4800 MT/s for 1 DIMM per channel, 4400 MT/s for 2 DIMMs
per channel
Voltage 1.1 V
The following table lists the supported DIMMs for the R660. For the latest information about supported memory and memory
configurations, reference the latest SDL.
Memory subsystem 15
6
Storage
Topics:
• Storage controllers
• Supported Drives
• Internal storage configuration
• External Storage
Storage controllers
Dell RAID controller options offer performance improvements, including the fPERC solution. fPERC provides a base RAID HW
controller without consuming a PCIe slot by using a small form factor and high-density connector to the base planar.
16G PERC Controller offerings are a heavy leverage of 15G PERC family. The Value and Value Performance levels carry over
to 16G from 15G. New to 16G is the Avenger-based Premium Performance tier offering. This high-end offering drives IOPs
performance and enhanced SSD performance.
Avenger 1
NOTE: For more information about the features of the Dell PowerEdge RAID controllers (PERC), Software RAID
controllers, or BOSS card, and on deploying the cards, see the storage controller documentation at www.dell.com/
storagecontrollermanuals.
NOTE: From December 2021, H355 replaces H345 as the entry raid controller. H345 is deprecated in January 2022.
Supported Drives
The table shown below lists the internal drives supported by the R660.
16 Storage
Table 7. Supported Drives
Form Factor Type Speed Rotational Capacities
Speed
2.5 inches vSAS 12 Gb SSD 1.92 TB, 3.84 TB, 960 GB, 7.62 TB
2.5 inches SAS 24 Gb SSD 1.92 TB, 1.6 TB, 800 GB, 3.84 TB, 960 GB, 7.68 TB
2.5 inches SATA 6 Gb SSD 1.92 TB, 480 GB, 960 GB, 3.84 TB,
2.5 inches NVMe Gen4 SSD 1.6 TB, 3.2 TB, 6.4 TB, 1.92 TB, 3.84 TB, 15.63 TB, 7.68 TB, 800
GB, 400 GB
2.5 inches DC NVMe Gen4 SSD 3.84 TB, 960 GB
2.5 inches SAS 12 Gb 10 K 600 GB, 1.2 TB, 2.4 TB
External Storage
The R660 support the external storage device types listed in the table below.
Storage 17
7
Networking
Topics:
• Overview
• OCP 3.0 support
Overview
PowerEdge offers a wide variety of options to get information moving to and from our servers. Industry best technologies are
chosen, and systems management features are added by our partners to firmware to tie in with iDRAC. These adapters are
rigorously validated for worry-free, fully supported use in Dell servers.
18 Networking
Table 10. Supported OCP cards (continued)
Form factor Vendor Port type Port speed Port count
Intel BT 10 GbE 4
Broadcom BT 1 GbE 4
Intel BT 1 GbE 4
Networking 19
8
PCIe subsystem
The R660 supports up to 3 x16 low profile slots by riser2 and riser3. All PCIe ports are 75W card edge delivered power per slot.
Topics:
• PCIe risers
PCIe risers
The PowerEdge R660 have a no riser option. Shown below are the riser offerings for the PowerEdge R660.
20 PCIe subsystem
Figure 9. Riser 1P
1. Slot 1
PCIe subsystem 21
Figure 11. Riser 2A
1. Slot 1
2. Slot 2
22 PCIe subsystem
Figure 13. Riser 3P
1. Slot 3
PCIe subsystem 23
Figure 15. Riser 2R
1. Slot 1
24 PCIe subsystem
Figure 17. Riser 3Q
1. Slot 3
PCIe subsystem 25
Figure 19. Riser 3R
1. Slot 3
26 PCIe subsystem
9
Power, thermal, and acoustics
PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate
temperature thereby reducing server noise and power consumption. The table below lists the tools and technologies Dell offers
to lower power consumption and increase energy efficiency.
Topics:
• Power
• Thermal
• Acoustics
Power
Table 13. Power tools and technologies
Feature Description
Power Supply Units(PSU) Dell's PSU portfolio includes intelligent features such as dynamically optimizing efficiency while
portfolio maintaining availability and redundancy. Find additional information in the Power supply units
section.
Tools for right sizing Enterprise Infrastructure Planning Tool (EIPT) is a tool that can help you determine the most
efficient configuration possible. With Dell's EIPT, you can calculate the power consumption
of your hardware, power infrastructure, and storage at a given workload. Learn more at
www.dell.com/calc.
Industry Compliance Dell's servers are compliant with all relevant industry certifications and guide lines, including 80
PLUS, Climate Savers and ENERGY STAR.
Power monitoring accuracy PSU power monitoring improvements include:
● Dell's power monitoring accuracy is currently 1%, whereas the industry standard is 5%
● More accurate reporting of power
● Better performance under a power cap
Power capping Use Dell's systems management to set the power cap limit for your systems to limit the output
of a PSU and reduce system power consumption. Dell is the first hardware vendor to leverage
Intel Node Manager for circuit-breaker fast capping.
Systems Management iDRAC Enterprise and Datacenter provides server-level management that monitors, reports and
controls power consumption at the processor, memory and system level.
Dell OpenManage Power Center delivers group power management at the rack, row, and data
center level for servers, power distribution units, and uninterruptible power supplies.
Active power management Intel Node Manager is an embedded technology that provides individual server-level power
reporting and power limiting functionality. Dell offers a complete power management solution
comprised of Intel Node Manager accessed through Dell iDRAC9 Datacenter and OpenManage
Power Center that allows policy-based management of power and thermal at the individual
server, rack, and data center level. Hot spare reduces power consumption of redundant power
supplies. Thermal control off a speed optimizes the thermal settings for your environment to
reduce fan consumption and lower system power consumption.
Idle power enables Dell servers to run as efficiently when idle as when at full workload.
NOTE: If a system with AC 1400 W or 1100 W PSUs operates at low line 100-120 Vac, and then the power rating per PSU is
degraded to 1050 W.
NOTE: C13 power cord combined with C14 to C15 jumper power cord can be used to adapt 1800 W PSU.
Thermal
PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate
temperature thereby reducing server noise and power consumption.
Thermal design
Thermal management of the platform helps deliver high performance with the right amount of cooling to components, while
maintaining the lowest fan speeds possible. This is done across a wide range of ambient temperatures from 10°C to 35°C (50°F
to 95°F) and to extended ambient temperature ranges.
Acoustics
Acoustical performance
Dell PowerEdge R660 is a rack-mount server appropriate for attended data center environment. However, lower acoustical
output is attainable with proper hardware or software configurations.
(1) LwA,m:The declared mean A-weighted sound power level (LwA) is calculated per section 5.2 of ISO 9296 (2017) with data
collected using the methods that are described in ISO 7779 (2010). Engineering data presented here may not be fully compliant
with ISO 7779 declaration requirement.
(2) LpA,m:The declared mean A-weighted emission sound pressure level is at the bystander position per section 5.3 of ISO 9296
(2017) and measured using methods that are described in ISO 7779 (2010). The system is placed in a 24U rack enclosure, 75 cm
above a reflective floor. Engineering data presented here may not be fully compliant with ISO 7779 declaration requirement.
(3) Prominent tones: Criteria of Annex D of ECMA-74 and Prominence Ratio method of ECMA-418 are followed to determine if
Table 19. Dell Enterprise Category 4, “Attended Data Center” acoustical specification category.
Measurement Metric, re Test Modes, re AC0159 (note must be in steady state, see Simulate (that
Position re AC0159 AC0159, except where noted below) is, set fan
AC0158 speeds
Standby in Idle in 23±2° C Operating in Simulate (that representative
23±2° C Ambient 23±2° C is, set fan ) for 100%
Ambient Ambient – if speeds loading and
not otherwise representative maximum
specified in ) for Idle at configuration,
the program’s 28° C & 35° C at 35° C
configuration Ambient Ambient
document,
then processor
and hard drive
operating
modes are
required
Sound Power LWA,m, B Report ≤ 6.9 ≤ 7.1 Report ≤ 8.5
Front Binaural Tones, Hz, dB Report < 15 dB < 15 dB Report < 20 dB
HEAD
Tonality, tu Report Report Report Report Report
Dell Modulation, Report Report Report Report Report
%
Loudness, sones Report Report Report Report Report
LpA-single Report Report Report Report Report
point, dBA
Transients ● Oscillation (see AC0159), if observed, during 20- N/A
minute steady-state observation, must adhere to
the following two criteria:
○ Max. {ΔLpA} < 3.0 dB
○ Event count < 3 for “1.5 dB < ΔLpA < 3.0 dB”
○ Acoustical Jump (see AC0159), during air
mover speed transition from Idle to Operating
Mode must be ≤ 15 dB.
○ Startup behavior
■ Report Startup behavior re. AC0159
■ Startup must proceed smoothly, that is,
no sudden or large jumps, and fan speed
during startup must not exceed 50% of its
maximum
∞ Transient inputs: Report time-history sound
pressure levels re AC0159 “Train of Step
Functions on Processor”
Sound should be “even” around the EUT (one side should not be dramatically louder than
another)
Unless otherwise specified, the “default” thermal-related settings shall be selected for
BIOS and iDRAC.
Sound Pressure LpA-reported, Report for all Report for all Report for all Report for all Report for all
dBA mics mics mics mics mics
Table 20. Dell Enterprise Category 5, “Unattended Data Center” acoustical specification category
Measuremen Metric, re Test Modes, re AC0159 (note must be in steady state, see AC0159, Simulate (that
t Position re AC0159 except where noted below) is, set air
AC0158 mover speeds
Standby in Idle in 23±2° Operating in Simulate (that is, representative
23±2° C C Ambient 23±2° C set air mover speeds ) for 100%
Ambient Ambient – if representative) for Idle at loading and
not 28° C & 35° C Ambient maximum
otherwise configuration,
specified in at 35° C
the Ambient
program’s
configuratio
n document,
then
processor
and hard
drive
operating
modes are
required
Sound Power LWA,m, B Report ≤ 7.5 ≤ 7.7 Report ≤ 8.7
Front Binaural Tones, Hz, dB Report < 15 dB < 15 dB Report < 20 dB
HEAD
Tonality, tu Report Report Report Report Report
Dell Report Report Report Report Report
Modulation,
%
Sound should be “even” around the EUT (one side should not be dramatically louder than
another)
Unless otherwise specified, the “default” thermal-related settings shall be selected for BIOS
and iDRAC.
Sound LpA-reported, Report for all Report for all Report for all Report for all mics Report for all
Pressure dBA, re mics mics mics mics
AC0158 and
program
configuration
document
For a full list of iDRAC features by license tier, see Integrated Dell Remote Access Controller 9 User's Guide at Dell.com.
For more details on iDRAC9 including white papers and videos, see:
● Support for Integrated Dell Remote Access Controller 9 (iDRAC9) on the Knowledge Base page at Dell.com
The new Factory Services consist of two tiers of deployment that happen prior to shipping to the customer's site.
Factory Based Services:
● ProDeploy Factory Configuration - Ideal for customers buying servers in volume and seeking pre-configuration prior to
shipping such as: custom image, system settings, and asset tagging so it arrives ready to use out of the box. Furthermore,
servers can be packaged and bundled to meet specific shipping and distribution requirements for each customer location to
facilitate the rollout process. Upsell one of the field based services (below) if a customer needs assistance with the final
server installation.
● ProDeploy Rack Integration - Ideal for customers seeking to build out fully integrated racks prior to shipping. These rack
builds include hardware install, cabling, and full system configuration. You can also add-on a factory stress test and optional
on-site final rack configuration to complete the rack installation.
○ STANDARD SKUs for Rack Integration is available in US only and requires:
■ 20 or more devices (R and C series servers and all Dell or non-Dell switches). Use Informational SKUs for Dell
switches or 3rd party products
■ Shipping to contiguous US
○ USE CUSTOM QUOTE for Rack Integration for:
■ All countries except USA
■ Racks containing less than 20 servers
■ Any rack that includes VxRail or Storage
■ Shipping outside contiguous US
■ Shipping to multiple locations
Field Based Services:
● Basic Deployment consists of the hardware installation, cabling and firmware update during normal standard business hours.
Basic Deployment is traditionally sold to Competency Enabled Partners. Competency enabled partners often have Dell do the
hardware installation while they complete the software configuration.
● ProDeploy consists of your hardware installation and configuration of the software using offshore resources. ProDeploy is
great for customers who are price sensitive or who are remote from their data centers and don't require an onsite presence.
● ProDeploy Plus will give you in-region or onsite resources to complete the engagement for the customer. It also comes with
additional features such as Post Deployment Configuration Assistance and Training Credits.
Dell ProDeploy for HPC (available in US/Canada only. All other regions use custom)
HPC deployments require specialists that understand that cutting edge is yesterday's news. Dell deploys the world 's fastest
systems and understands the nuances that make them perform. ProDeploy for HPC provides:
● Global team of dedicated HPC specialists
● Proven track record, thousands of successful HPC deployments
● Design validation, benchmarking, and product orientation
Learn more at Dell.com/HPC-Services.
Support Technologies
Powering the support experience with predictive, data-driven technologies.
NOTE: SupportAssist Enterprise capabilities are now part of the secure connect gateway technology.
Enterprise connectivity
The best time to solve a problem is before it happens. The automated proactive and predictive support features enabled by the
secure connect gateway technology helps reduce steps and time to resolution, often detecting issues before they become a
crisis. The gateway technology is available in virtual and application editions. It is also implemented as a direct connect version
for select Dell hardware and a Services plugin within OpenManage Enterprise for PowerEdge servers. The legacy SupportAssist
Enterprise solution has been retired and is now replaced by the secure connect gateway solutions.
Benefits include:
● Value: Our connectivity solutions are available to all customers at no additional charge
● Improve productivity: Replace manual, high-effort routines with automated support
● Accelerate time to resolution: Receive issue alerts, automatic case creation, and proactive contact from Dell experts
● Gain insight and control: Optimize enterprise devices with insights in portals reporting like TechDirect, and get predictive
issue detection before the problem starts
NOTE: Connect devices can access these features. Features vary depending on the service level agreement for the
connected device. ProSupport Plus customers experience the full set of automated support capabilities.
Dell TechDirect
TechDirect helps boost IT team productivity when supporting Dell systems.
Boost your productivity with online servoce for Dell products from TechDirect. From deployment to technical support,
TechDirect lets you do more with less effort and faster resolution. You can:
● OPen and manage support requests or in-warranty systems
● Execute online self-service for parts dispatch
● Collaborate on ProDeploy infrastructure deployment projects online
● Manage proactive and preditive alerts from secure connect gateway technology that help maximize uptime
● Integrate services functionality into your help desk with TechDirect APIs
● Join over 10,000 companies that choose TechDirect
Register at TechDirect.Dell.com.
Chassis dimension
The R660 has the following dimensions:
0 drive 482.0 mm (18.97 434.0 mm 42.8 mm (1.68 35.84 mm (1.41 700.7 mm (27.5 736.27 mm
inches) (17.08 inches) inches) inches) With inches) Ear to (28 inches)
bezel rear wall Ear to rear
wall
22 mm (0.86
inches)
Without bezel
14xE3.S drives / 482.0 mm (18.97 434.0 mm 42.8 mm (1.68 35.84 mm (1.41 751.47 mm (17 787.04 mm
16xE3.S drives inches) (17.08 inches) inches) inches) With inches) Ear to (30 inches)
bezel rear wall Ear to PSU
handle
22 mm (0.86
inches)
Without bezel
NOTE: Zb is the nominal rear wall external surface where the system board I/O connectors reside.
Chassis weight
Table 27. PowerEdge R660 system weight
System configuration Maximum weight (with all drives/SSDs)
A server with fully populated drives 22.51 kg (49.62 lbs)
A server without drives and PSU installed 18.5 kg (40.78 lbs)
NOTE: The system allows either LOM card or an OCP card or both to be installed in the system.
NOTE: On the system board, the supported OCP PCIe width is x8; when x16 PCIe width is installed, it is downgraded to x8.
*DVO - DP is for investigation only, dependent on Nuvoton DVO capabilities to support up to 165MHz. Rear Panel Performance
is TBD subject to final board design and losses to rear VGA connector.
*(RB) - Reduced Blanking for Digital Displays requiring less blank time. This was introduced for Signal Integrity improvements by
reducing Pixel Clock rates for VGA- Analog input devices.
NOTE: The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
Front USB 2.0 port only supports output current up to 0.5A and can't support high power consumption devices such as
CD-ROM. The bottom port of the rear USB connector can support USB3.0 to supply output current up to 0.9A.
PSU rating
Table 31. PSUs Highline and Lowline ratings
Features 700 W 800 W 1100 W 1100 W 1400 W 1800 W
Titanium Platinum Titanium -48VDC Platinum Platinum
The PowerEdge R660 supports up to two AC or DC power supplies with 1+1 redundancy, autosensing, and auto-switching
capability.
If two PSUs are present during POST, a comparison is made between the wattage capacities of the PSUs. In the event that the
PSU wattages don’t match, the larger of the two PSU’s is enabled. Also, there is a PSU mismatch warning displayed in BIOS,
iDRAC, or on the System LCD.
If a second PSU is added at run-time, in order for that particular PSU to be enabled, the wattage capacity of the first PSU must
equal the second PSU. Otherwise, the PSU will be flagged as unmatched in iDRAC and the second PSU will not be enabled.
Dell PSUs have achieved Platinum efficiency levels as shown in the table below.
Environmental Specifications
See the PowerEdge R660 Technical Specifications on www.dell.com/poweredgemanuals for detailed environmental
specifications.
The table below details the environmental specifications for the platform. For additional information about environmental
measurements for specific system configurations, see Product Safety, and Environmental datasheets.
The table below shows the requirements shared across all environmental categories
ASHRAE A2 environment
● CPU > 300W are not supported in 10 x 2.5 inch storage configuration.
● CPU > 270W are not supported in 10 x 2.5 inch storage with rear drive configuration.
● Maximum 30°C (86°F) for CPU > 270 W in10 x 2.5 inch storage configuration..
● Maximum 30°C (86°F) for CPU > 250 W with rear drive in 10 x 2.5 inch storage configuration.
● Maximum 30°C (86°F) for CPU > 250 W with 256G RDIMM in 10 x 2.5 inch storage configuration.
● Maximum 30°C (86°F) for CPU > 225 W with 256G RDIMM in 10 x 2.5 rear drive configuration.
● CPU > 350W are not supported in no BP chassis storage configuration.
● Maximum 30°C (86°F) for CPU > 300W in no BP chassis storage configuration.
● CPU > 350W are not supported in 8 x 2.5 inch storage configuration.
● Maximum 30°C (86°F) for CPU > 300 W in 8 x 2.5 inch storage configuration.
ASHRAE A3 environment
● CPU > 185W are not supported in 10 x 2.5 inch storage configuration.
● CPU > 205W are not supported in 8 x 2.5 inch and no BP chassis storage configuration.
● 128 GB or greater capacity RDIMMs are not supported.
● 2.5 inch NVMe storage are not supported in a 8 x 2.5 inch and 10 x 2.5 inch storage configuration.
● Rear drives are not supported.
● Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
● A2 GPU is not supported.
● 85°C (185°F) active optics cable is required.
● Two power supplies are required. System performance may be reduced in the event of a PSU failure.
ASHRAE A4 environment
● CPU > 125W are not supported in 10 x 2.5 inch storage configuration.
● 128 GB or greater capacity RDIMMs are not supported.
● Rear drives are not supported.
● 2.5 inch NVMe storage are not supported.
● BOSS N1 is not supported.
● A2 GPU is not supported.
● Two power supplies are required. System performance may be reduced in the event of a PSU failure.
● Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
● OCP 3.0 card is not supported.
● 85°C (185°F) active optics cable is required.
NOTE:
● *Supported ambient temperature is 30°C (86°F) .
● Required DLC requires <30°C (86°F)
NOTE:
● Install all fan modules for single CPU configuration.
NOTE: Not required for C04-08 configuration.
● All air-cooling configurations require a CPU shroud.
● Install PCH shroud for no riser configuration.
● Install Rear drive shroud for air-cooling with 2x 2.5-inch rear drive configuration.
● Install A2 blank on R1p riser for FH riser configuration with A2 GPU.
● Install DIMM blanks in all empty DIMM slots for STD CPU heat sink or CPU TDP >=250W.
● Chassis features
● System Setup program
● System indicator codes
● System BIOS
● Remove and replace procedures
● Diagnostics
● Jumpers and connectors
Getting Started Guide This guide ships with the system, and is Dell.com/Support/Manuals
also available in PDF format. This guide
provides the following information: