Device Compatibility Document
Device Compatibility Document
ACPS-2406
Addressable Charger / Power Supply
Use with the AFP-100, AFP-200, AFP-300/400,
AFC-600, AFP-1010/AM2020, NFS-640, NFS-3030 Control Panels
NAC Power: Filtered
Selectable Synchronization with System Sensor SpectrAlert® Series horn and strobes, Gentex, or Cooper Wheelock horns and strobes.
APS-6R
Auxiliary Power Supply
Use with the AFC-640, AFP-300/400, AFP-1010 / AM2020, NFS-640, NFS-3030, System 500, System 5000, and XP Transponder
Control Panels
NAC Power: Filtered
AVPS-24
Audio/Visual Power Supply
Use with the AFP-200, AFP-1010 / AM2020, System 500, System 5000, XP Transponder, Control Panels
NAC Power: Full Wave Rectified
FCPS-24
Field Charger/ Power Supply
Input Voltage: 9 to 32 VDC
19.1 - 26.4 VDC range for compatibility
NAC Power: Filtered
MMX-2, FZM-1
Monitor Modules
Initiating Loop Voltage: 16 - 27.5 VDC
Compatibility Identifier: "A"
XPIQ
Quad Intelligent Audio Transponder
Compatibility Identifier: "A"
Use with the AFC-600, AFP-300/400, AFP-1010/AM2020, NFS-640, NFS-3030 Control Panels
NAC Power: Filtered (uses APS-6R, FCPS-24)
XP6-MA
Six-Zone Interface Module
Compatibility Identifier: "A"
Use with the NFS-640 and NFS-3030 Control Panels
Normal Operating Voltage: 15 - 32 VDC
Stand-By Current: 2 mA
XP SERIES (XPM-8)
Transponder Monitor Module
Initiating Loop Voltage: 24 VDC Nominal
Max Detector Loop Standby Current: 3.5 mA/Loop
Compatibility Identifier: "A"
NAC Power: MPS-24A Filtered
AMPS-24
Addressable Charger / Power Supply
ACPS-610/E
Use with any addressable CLIP or FlashScan FACP.
Addressable Charger / Power Supply
CPS-24: 5V Output: 4.97 - 4.99 VDC
Use with any addressable CLIP or FlashScan Fire Alarm Control
24V Output: 19.95 - 26.23 VDC
Panel.
AMPS-K2: 24V Main: 20.14 - 26.42 VDC
Selectable Synchronization with System Sensor Series horn and
24V Aux: 20.28 - 26.42 VDC
strobes, or Gentex, or Cooper Wheelock horns and strobes.
NAC Power: KAPS-24 Filtered
19.4 to 26.4 VDC range for compatibility
PSE-6(E)(C)(R), PSE-10(E)(C)(R)
NAC Power: CPS-24 Filtered
Battery Charger / Power Supply
5V Output: 4.97 - 4.99 VDC
NAC Power: Filtered (Special Application)
24V Output: 19.57 - 26.38 VDC
Selectable Strobe Synchronization for NACs
(System Sensor, Gentex, Cooper Wheelock, and AMSECO)
Range: 19.2 – 26.4 VDC
APS2-6R(E)
24V Output (NAC1-NAC5/7): 19.72 – 26.40
Auxiliary Power Supply
MAX Ripple Voltage 780 mVp-p
Use with the NFS2-3030, NFS2-640, NFS-320, NFS-320SYS/E,
Remote Sync Input Voltage: 9 to 32 VDC
AFP-200, AFP-300/400, AFP-1010 / AM2020, NFS-640, NFS-
3030, System 5000 Control Panels, XP Transponder, XPIQ,
IPDACT-2, RM-1, NWS, HS-NCM Series, ACS Series
Annunciators
Power: Filtered (Special Application)
AFP-200, AFP-300 / 400, AFC-600, NFS-640, NFS2-640, NFS-320, NFS2-3030, NFS-3030, AM2020 / AFP-1010, RP-1001,
RP-2001, S500 (TC-2/TC-4), S5000 (TCM-2/TCM-4), XP5-C, FCM-1, N16
Solenoid Group [A]
Skinner solenoid valve Model LV2LBX25, 24 VDC, 11 Watts, 458 mA, 1/2 in. NPS, 5/8 in. orifice.
Solenoid Group [B] These valves are interchangeable.
ASCO solenoid valve Model T8210A107, 24 VDC, 16.8 Watts, 700 mA, 1/2 in. NPS, 5/8 in. orifice.
ASCO solenoid valve Model R8210A107, 24 VDC, 16.8 Watts, 700 mA, 1/2 in. NPS, 5/8 in. orifice.
ASCO solenoid valve Model 8210A107, 24 VDC, 16.8 Watts, 700 mA, 1/2 in. NPS, 5/8 in. orifice.
Solenoid Group [C]
Star Sprinkler Corp. Solenoid P/N 5550, 24 VDC, part of Model D deluge valve.
Solenoid Group [D]
ASCO solenoid valve Model 8210G207, 24 VDC, 10.6 Watts, 440 mA, 1/2 in. NPS, 1/2 in. orifice.
Solenoid Group [E]
Skinner solenoid valve Model 73218BN4UNLVNOC111C2, 24 VDC, 10 Watts, 420 mA, 1/2 in. NPS, 5/8 in. orifice.
Solenoid Group [F]
Skinner solenoid valve Model 73212BN4TNLVNOC322C2, 24 VDC, 22 Watts, 0.92 A, 1/2 in. NPS, 1/2 in. orifice, 250 psi (1725 kPa).
UL Listed 24VDC solenoids for use with the following Panels: NFS2-3030 with FCM-1 and FCM-1-REL (FCM-1-RELA for Canada)
Control Modules, NFS2-640, and NFS-320 [with FCM-1 or FCM-1-REL (FCM-1-RELA for Canada) Control Module, NACs, or
both], RP-2001, and RP-2002
The AMPS-24 has up to 3 amps of power for releasing applications and the APS2-6R has up to 6 amps of power, but both are limited by
the capacity of the FCM-1-REL. (Refer to the appropriate panel installation manual to determine the available power output.)
System Sensor devices can be used only with Panels LISTED for use with this Series Notification Appliance. All models with suffix
“A” are marketed for Canada.
For use with 10th Edition panels/supplies: FireWarden-50X, FireWarden-100X, NFS2-640(E), NFS-320(E/C), NFS-320SYS(E),
NFS2-3030(E), N16 Series, PSE-6(C)(E), PSE-10(C)(E), AMPS-24
For use with 9th Edition panels/supplies: FireWarden-50(E), FireWarden-100-2(E), SFP-2402(E), SFP-2404(E), SFP-5UD(E)(C), SFP-
10UD(E)(C), RP-2001(E), RP-2002(E), FCPS-24S6, FCPS-24S8, ACPS-610
UL 464 directional Sounder, supplemental notification appliance. The directional sounder can be installed in systems using 24 Volt DC
regulated power supplies only. It is not approved for use with FWR unregulated power supplies.
Rated Sync.
FWR Filtered
System Sensor with MDL
Voltage2 DC DC
module
Notes:
1) All current draws are shown in milliamperes and reflect worst case average.
2) Nominal operating voltages shown.
3) Refer to manufacturer’s installation instructions for more information.
System Sensor CH SpectrAlert Advance Chime 24 VDC 54* 58* Yes
System Sensor CHS SpectrAlert Advance Chime/Strobe 24 VDC 220* 217* Yes
System Sensor CHSR SpectrAlert Advance Chime/Strobe 24 VDC * * Yes
System Sensor CHSW SpectrAlert Advance Chime/Strobe 24 VDC * * Yes
System Sensor HR SpectrAlert Advance Horn 24 VDC 75* 69* Yes
System Sensor MDL3R(A)/MDL3W(A) Sync Modules for use with SpectrAlert series (ULC) 24 VDC * * -
System Sensor MHR SpectrAlert Advance Mini-Horn 24 VDC 25 max 29 max Yes
System Sensor MHW SpectrAlert Advance Mini-Horn 24 VDC 25 max 29 max Yes
System Sensor P2R SpectrAlert Advance Horn/Strobe 24 VDC 229* 229* Yes
System Sensor P2RH SpectrAlert Advance Horn/Strobe High 24 VDC 281* 309* Yes
System Sensor P4R SpectrAlert Advance 4-wire Horn/Strobe Standard 24 VDC 280* 279* Yes
System Sensor P4RH SpectrAlert Advance Horn/Strobe High 24 VDC 333* 355* Yes
System Sensor PC2R SpectrAlert Advance 2 wire Horn/Strobe Standard 24 VDC 229* 229* Yes
System Sensor PC2RH SpectrAlert Advance 2-wire Horn/Strobe High 24 VDC 281* 309* Yes
System Sensor PC4R SpectrAlert Advance 4-wire Horn/Strobe 24 VDC 280* 279* Yes
System Sensor PC4RH SpectrAlert Advance 4-wire Horn/Strobe High 24 VDC 333* 355* Yes
System Sensor SCR SpectrAlert Advance Strobe Standard 24 VDC 205* 210* Yes
System Sensor SCRH SpectrAlert Advance Strobe High 24 VDC 258* 286* Yes
System Sensor SEP-SPSW SpectrAlert Advance Speaker Strobe Expander Plate amber lens 24 VDC 205* 210* Yes
System Sensor SEP-SW SpectrAlert Advance Strobe Expander Plate amber lens 24 VDC 205* 210* Yes
System Sensor SR SpectrAlert Advance Horn/Strobe 24 VDC 205* 210* Yes
System Sensor SRH SpectrAlert Advance Strobe High 24 VDC 258* 286* Yes
System Sensor SPR SpectrAlert Advance Wall Red Speaker 25/70.7Vrms * * N/A
System Sensor SPW SpectrAlert Advance Wall White Speaker 25/70.7Vrms * * N/A
System Sensor SPRV SpectrAlert Advance Wall Red Speaker Hi dB 25/70.7Vrms * * N/A
System Sensor SPWV SpectrAlert Advance Wall White Speaker Hi dB 25/70.7Vrms * * N/A
System Sensor SPRK SpectrAlert Advance Wall Outdoor Red Speaker 25/70.7Vrms * * N/A
System Sensor SPWK SpectrAlert Advance Wall Outdoor White Speaker 25/70.7Vrms * * N/A
System Sensor SPSR SpectrAlert Advance Wall Red Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSR-P SpectrAlert Advance Wall Speaker/Strobe, Red, Plain 24 VDC 205* 210* Yes†
System Sensor SPSRH SpectrAlert Advance Wall Red Speaker/Strobe Hi Cd 24 VDC 258* 286* Yes†
System Sensor SPSRH-P SpectrAlert Advance Red Wall Speaker/Strobe Hi Cd, Plain 24 VDC 258* 286* Yes†
System Sensor SPSW SpectrAlert Advance Wall White Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSW-ALERT SpectrAlert Advance Wall White Speaker/Strobe Amber Lens, ALERT 24 VDC 205* 210* Yes†
System Sensor SPSW-CLR-ALERT SpectrAlert Advance White Wall Speaker/Strobe, Clear Lens, ALERT 24 VDC 205* 210* Yes†
System Sensor SPSW-P SpectrAlert Advance Wall White Speaker/Strobe, Plain 24 VDC 205* 210* Yes†
System Sensor SPSWH SpectrAlert Advance Wall Speaker/Strobe Hi Cd 24 VDC 258* 286* Yes†
System Sensor SPSWH-P SpectrAlert Advance Wall Speaker/Strobe Hi Cd, Plain 24 VDC 258* 286* Yes†
System Sensor SPSRV SpectrAlert Advance Wall Red Hi dB Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSWV SpectrAlert Advance Wall White Hi dB Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSRK SpectrAlert Advance Wall Outd. Red Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSWK SpectrAlert Advance Wall Outd. White Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPCW SpectrAlert Advance Ceiling White Speaker 25/70.7Vrms * * N/A
System Sensor SPCR SpectrAlert Advance Ceiling Red Speaker 25/70.7Vrms * * N/A
System Sensor SPCWV SpectrAlert Advance Ceiling White Speaker Hi dB 25/70.7Vrms * * N/A
System Sensor SPCRV SpectrAlert Advance Ceiling Red Speaker Hi dB 25/70.7Vrms * * N/A
System Sensor SPCWK SpectrAlert Advance Ceiling Outdoor White Speaker 25/70.7Vrms * * N/A
System Sensor SPSCR SpectrAlert Advance Ceiling Red Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSCRH SpectrAlert Advance Ceiling Red Speaker/Strobe Hi Cd 24 VDC 258* 286* Yes†
System Sensor SPSCW SpectrAlert Advance Ceiling White Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSCW-CLR-ALERT SpectrAlert Advance Ceiling White Speaker/Strobe, Clear Lens, ALERT 24 VDC 205* 210* Yes†
Rated Sync.
FWR Filtered
System Sensor 2 with MDL
Voltage DC DC
module
Notes:
1) All current draws are shown in milliamperes and reflect worst case average.
2) Nominal operating voltages shown.
3) Refer to manufacturer’s installation instructions for more information.
System Sensor SPSCW-P SpectrAlert Advance Ceiling White Speaker/Strobe, Plain 24 VDC 205* 210* Yes†
System Sensor SPSCWH SpectrAlert Advance Ceiling White Speaker/Strobe Hi Cd 24 VDC 258* 286* Yes†
System Sensor SPSCWH-P SpectrAlert Advance Ceiling White Speaker/Strobe Hi Cd, Plain 24 VDC 258* 286* Yes†
System Sensor SPSCRV SpectrAlert Advance Ceiling Red Hi dB Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSCRVH SpectrAlert Advance Ceiling Red Hi dB Speaker/Strobe Hi Cd 24 VDC 258* 286* Yes†
System Sensor SPSCWV SpectrAlert Advance Ceiling White Hi dB Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSCWVH SpectrAlert Advance Ceiling White Hi dB Speaker/Strobe Hi Cd 24 VDC 258* 286* Yes†
System Sensor SPSCWK SpectrAlert Advance Ceiling Outdoor White Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SPSCWHK SpectrAlert Advance Ceiling Outdoor White Speaker/Strobe 24 VDC 205* 210* Yes†
System Sensor SW-ALERT SpectrAlert Advance Wall amber lens Strobe 24 VDC 205* 210* Yes
System Sensor SWH-ALERT SpectrAlert Advance Wall amber lens Strobe Hi Cd 24 VDC 258* 286* Yes
* Contact manufacturer for current draws.
† The strobe portion
Table 10: System Sensor L-Series Notification Appliances Low-Frequency Devices (UL-464 Listed)
Rated Filtered Sync. with
System Sensor FWR DC
Voltage2 DC MDL module
Notes:
1) All current draws are shown in milliamperes and reflect worst case average.
2) Nominal operating voltages shown.
3) Refer to manufacturer's installation instructions for more information.
System Sensor HCRL-LF Red Ceiling Horn 24 VDC 305 368 Yes
System Sensor HCWL-LF White Ceiling Horn 24 VDC 305 368 Yes
System Sensor HGRL-LF Compact Red Horn 24 VDC 305 368 Yes
System Sensor HGWL-LF Compact White Horn 24 VDC 305 368 Yes
System Sensor HRL-LF Red Wall Horn 24 VDC 305 368 Yes
System Sensor HWL-LF White Wall Horn 24 VDC 305 368 Yes
System Sensor P2RL-LF Red Horn Strobe, 2-wire 24 VDC 305 368 Yes
System Sensor P2WL-LF White Horn Strobe, 2-wire 24 VDC 305 368 Yes
System Sensor PC2RL-LF Red Ceiling Horn Strobe 24VDC 305 368 Yes
System Sensor PC2WL-LF While Ceiling Horn Strobe 24VDC 305 368 Yes
System Sensor SPCRL Red Ceiling Speaker 25/70.7Vrms - - N/A
System Sensor SPCWL White Ceiling Speaker 25/70.7Vrms - - N/A
System Sensor SPRL Red Wall Speaker 25/70.7Vrms - - N/A
System Sensor SPWL White Wall Speaker 25/70.7Vrms - - N/A
System Sensor SPSCRL Red Ceiling Speaker/Strobe 24 VDC 264 226 Yes
System Sensor SPSCWL White Ceiling Speaker/Strobe 24 VDC 264 226 Yes
System Sensor SPSRL Red Wall Speaker/Strobe 24 VDC 264 226 Yes
System Sensor SPSRL-SP Red Wall Speaker/Strobe, Spanish 24 VDC 264 226 Yes
System Sensor SPSWL White Wall Speaker/Strobe 24 VDC 264 226 Yes
System Sensor SPSCWL-P White Ceiling Speaker/Strobe, Plain 24 VDC 257 222 Yes
System Sensor SPSCWL-SP White Ceiling Speaker/Strobe, Plain 24 VDC 257 222 Yes
System Sensor SPSRL-P Red Ceiling Speaker/Strobe, Plain 24 VDC 257 222 Yes
System Sensor SPSWL-P White Ceiling Speaker/Strobe, Plain 24 VDC 257 222 Yes
System Sensor SPSCWL-CLR-ALERT White Ceiling Speaker/Strobe, Clear Lens 24 VDC 257 222 Yes
System Sensor SPSWL-ALERT White Wall Speaker/Strobe, Amber Lens 24 VDC 257 222 Yes
System Sensor SPSWL-CLR-ALERT White Wall Speaker Strobe, Clear Lens 24 VDC 257 222 Yes
System Sensor HCRLA-LF Red Ceiling Horn (ULC) 24 VDC * * Yes
System Sensor HCWLA-LF White Ceiling Horn (ULC) 24 VDC * *
Yes
* *
System Sensor HGRLZA-LF Compact Red Horn with Hush (ULC) 24 VDC Yes
* *
System Sensor HGWLZA-LF Compact White Horn with Hush (ULC) 24 VDC Yes
* *
System Sensor HRLA-LF Red Wall Horn (ULC) 24 VDC Yes
System Sensor HWLA-LF White Wall Horn (ULC) 24 VDC * * Yes
* *
System Sensor P2RLA-LF Red Horn Strobe, 2-wire (ULC) 24 VDC Yes
Table 11: System Sensor SpectrAlert Advance Low-Frequency Devices (UL-464 Listed) (1 of 2)
Rated Sync.
FWR Filtered
System Sensor 2 with MDL
Voltage DC DC
module
Notes:
1) All current draws are shown in milliamperes and reflect worst case average.
2) Nominal operating voltages shown.
3) Refer to manufacturer’s installation instructions for more information.
System Sensor HR-LF SpectrAlert Advance Low Frequency Sounder 24 VDC 153* 205* Yes
System Sensor HW-LF SpectrAlert Advance Low Frequency Sounder 24 VDC 153* 205* Yes
System Sensor P2RH-LF SpectrAlert Advance Low Frequency Sounder Strobe, High, Red 24 VDC 417* 433* Yes
System Sensor P2WH-LF SpectrAlert Advance Low Frequency Sounder Strobe, High, White 24 VDC 417* 433* Yes
System Sensor SPCR SpectrAlert Advance Ceiling High-Fidelity Speaker, Red 25/70.7Vrms * * N/A
System Sensor SPCW SpectrAlert Advance Ceiling High-Fidelity Speaker, White 25/70.7Vrms * * N/A
System Sensor SPR SpectrAlert Advance Wall High-Fidelity Speaker, Red 25/70.7Vrms * * N/A
System Sensor SPSCR SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, Red 24 VDC 205* 210* Yes†
System Sensor SPSCRH SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, High Candela, Red 24 VDC 258* 286* Yes†
System Sensor SPSCW SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, White 24 VDC 205* 210* Yes†
System Sensor SPSCW-CLR-ALERT SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, Clear Lens, 24 VDC 205* 210* Yes†
ALERT, White
System Sensor SPSCWH SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, High Candela, White 24 VDC 258* 286* Yes†
System Sensor SPSCWH-P SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, High Candela, Plain, 24 VDC 258* 286* Yes†
White
System Sensor SPSCW-P SpectrAlert Advance Ceiling High-Fidelity Speaker Strobe, Plain, White 24 VDC 205* 210* Yes†
System Sensor SPSR SpectrAlert Advance Wall High-Fidelity Speaker Strobe, Red 24 VDC 205* 210* Yes†
System Sensor SPSRH SpectrAlert Advance Wall High-Fidelity Speaker Strobe, High Candela, Red 24 VDC 258* 286* Yes†
System Sensor SPSRH-P SpectrAlert Advance Wall High-Fidelity Speaker Strobe, High Candela, Plain, Red 24 VDC 258* 286* Yes†
System Sensor SPSR-P SpectrAlert Advance Wall High-Fidelity Speaker Strobe, Plain, Red 24 VDC 205* 210* Yes†
System Sensor SPSW SpectrAlert Advance Wall High-Fidelity Speaker Strobe, White 24 VDC 205* 210* Yes†
System Sensor SPSW-ALERT SpectrAlert Advance Wall High-Fidelity Speaker Strobe, Amber Lens, ALERT, 24 VDC 205* 210* Yes†
White
Rated Sync.
FWR Filtered
System Sensor 2 with MDL
Voltage DC DC
module
Notes:
1) All current draws are shown in milliamperes and reflect worst case average.
2) Nominal operating voltages shown.
3) Refer to manufacturer’s installation instructions for more information.
System Sensor SPSW-CLR-ALERT SpectrAlert Advance Wall High-Fidelity Speaker Strobe, Clear Lens, 24 VDC 205* 210* Yes†
ALERT, White
System Sensor SPSWH SpectrAlert Advance Wall High-Fidelity Speaker Strobe, High Candela, White 24 VDC 258* 286* Yes†
System Sensor SPSWH-P SpectrAlert Advance Wall High-Fidelity Speaker Strobe, High Candela, Plain, White 24 VDC 258* 286* Yes†
System Sensor SPSW-P SpectrAlert Advance Wall High-Fidelity Speaker Strobe, Plain, White 24 VDC 205* 210* Yes†
System Sensor SPW SpectrAlert Advance Wall High-Fidelity Speaker, White 25/70.7Vrms * * N/A
* Contact manufacturer for current draws.
† The strobe portion
Control panels with notification circuits supplied by special application (FWR, filtered) power must use appliances listed in Table 12.
Control panels with notification circuits supplied by special application (FWR, filtered) power must use appliances listed in Table 13.
Control panels with notification circuits supplied by special application (FWR, filtered) power must use appliances listed in the
Table 14.
Control panels with notification circuits supplied by special application (FWR, filtered) power must use appliances listed in the
Table 15.
Control panels with notification circuits supplied by special application (FWR, filtered) power must use appliances listed in the
Table 16.