0% found this document useful (0 votes)
29 views6 pages

CSP LSP

The CSP-LSP is a device that protects Crestron control systems from lightning strikes and electrical disturbances on the Cresnet control line. It provides four-stage lightning suppression through components like spark gaps and transient voltage suppressors. The CSP-LSP can be installed near the control system to protect centralized devices or at the point where outdoor Cresnet cable enters a building to protect indoor devices. It has input and output ports to connect multiple Cresnet cable runs and can be daisy chained to additional units for large networks spanning multiple buildings.

Uploaded by

john
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views6 pages

CSP LSP

The CSP-LSP is a device that protects Crestron control systems from lightning strikes and electrical disturbances on the Cresnet control line. It provides four-stage lightning suppression through components like spark gaps and transient voltage suppressors. The CSP-LSP can be installed near the control system to protect centralized devices or at the point where outdoor Cresnet cable enters a building to protect indoor devices. It has input and output ports to connect multiple Cresnet cable runs and can be daisy chained to additional units for large networks spanning multiple buildings.

Uploaded by

john
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

CSP-LSP

Cresnet® Lightning Strike Protector


The CSP-LSP is an accessory designed to protect a Crestron
control system from lightning surges and other electrical
disturbances brought through the Cresnet control line.
Four-stage lightning suppression provides superior protection
against damage to the control system caused by lightning
strikes to remote Cresnet devices and wiring, especially
outdoor equipment and underground cabling. It is also
effective for protection against transients picked up by
indoor networks in any facility that is particularly prone to
near lightning strikes.
The CSP-LSP provides protection for a single control system
and any portion of its Cresnet network. It may be located
near the central equipment cabinet to protect only the SPECIFICATIONS
control system and centralized devices, or it may be Protection
installed at the point of entry from an outdoor Cresnet cable 4-stage protection employing spark gaps, gas discharge
to protect the entire indoor Cresnet network. For networks tubes, current limiters, and transient voltage suppressors
that span multiple buildings, a separate CSP-LSP can be Clamping Voltage: 33 Volts
installed in each building to protect all of the local Clamping Time: < 100 Picoseconds
devices within each building.
The CSP-LSP is designed for mounting to a wall or similar Connectors
flat surface. Two protected CONTROL SYSTEM ports are DEVICE: (4) 4-pin 3.5mm detachable terminal blocks;
provided, paralleled for easy daisy-chaining to a second Ground: (2) 10-32 studs, chassis ground lugs*;
CSP-LSP or other Cresnet equipment. Four paralleled DEVICE 3 ft (0.92 m) flat braided grounding strap included;
ports accommodate the connections from one or more remote CONTROL SYSTEM: (2) 4-pin 5mm detachable terminal blocks;
Cresnet wire runs. Two #10 ground lugs provide for
termination of the grounding cable. A 3 foot long braided
grounding strap is included, complete with a copper saddle Environmental

clamp for attachment to a suitable utility ground, cold water Temperature: -40° to 194°F (-40° to 90°C)

pipe, or grounding rod*. A bus bar is also included for Humidity: 10% to 90% RH (non-condensing)

daisy-chaining to a second CSP-LSP unit.


Enclosure
Zinc plated steel surface mount box with (2) integral
mounting flanges

www.crestron.com 800.237.2041
CSP-LSP
Cresnet® Lightning Strike Protector
Dimensions
Height: 1.83 in (4.65 cm)
Width: 5.64 in (14.32 cm)
Depth: 3.40 in (8.64 cm)

Weight
1.17 lb (0.53 kg)

Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647

Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905


CSP-LSP
Cresnet® Lightning Strike Protector
CSP-LSP Application 1
Protecting Control and Automation Systems in a Single Location

CK
B LO
N -H
C2
8

7
24
6 Y
24
Z
5 Y
24 G
Z
4 Y
24 G
Z LIB
3 Y CA
24 G
Z T
2 Y NE
c
24 G R
Z WE
1 Y PO b
24 G
Z
Y a
24 G
Z E
Y
G 24
Z D Y
24
G Z LL
EL
C Y G RA
24 PA
Z
B Y E IN
24 G AR
Z RS
A Y TO
24 G EC
Z NN
Y L CO
24 G AL
Z
Y
G
Z
G
CK
LO
HB
N-
C2

S P
P-L
CS
L
RO
NT M
CO STE Z
G
SY Y
24

E
VIC
DE
G
YZ
24 G
Z
N Y
STRO 24
G CRE
YZ
24
SP
P -L
CS

Grounded
G
YZ
24

Cold Water
G
YZ
24

Braided Pipe
Ground
Wire Pipe
Ground
Clamp
Cresnet Cable >500 ft.

C
A
E
N
4

CR
X

ES
1

TR
ON

AU
TO
M
SY ATIO
ST
EM N

CS
P-L
SP

Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647

Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905


CSP-LSP
Cresnet® Lightning Strike Protector
CSP-LSP Application 3
Protecting Control Systems with Multiple Interfaces

C K
LO
HB
N-
C2
8

7
24
6 Y
24
Z
5 Y
24 G
Z
4 Y
24 G
Z LIB
3 Y CA
24 G
Z T
2 Y NE
c
24 G R
Z WE
1 Y PO b
24 G
Z
Y a
24 G
Z E
Y
G 24
Z D Y
24
G Z LL
EL
C Y G RA
24 PA
Z
B Y E IN
24 G AR
Z RS
A Y TO
24 G EC
Z NN
Y L CO
24 G AL
Z
Y
G
Z
G
CK
LO
HB
N-
C2

-L SP
SP
L

C
RO
NT M
CO STE Z
G
SY Y
24

E
VIC
DE
G
YZ
24 G
Z
N Y
STRO 24
G CRE
YZ
24
SP
P -L
CS
G
YZ
24

G
YZ
24

Braided
Ground
Wire

Grounded
Cold Water Pipe

Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647

Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905


CSP-LSP
Cresnet® Lightning Strike Protector
CSP-LSP Application 2
Protecting Control and Autiomation Systems in Three Locations

BU
ILD IN G2
ING ILD
1 BU

CS
P-L -L SP
SP SP
OL

C
NTR
CO STEM Z
G
SY Y
24

ICE
DEV
G
YZ
24 G
Z
N Y
TRO 24
G CRES
YZ
24
SP
P -L
CS
G
YZ
24

G
YZ
24

Braided
Ground Wire
Pipe
Ground
Pipe Clamp
Ground
Clamp

Grounded
G3
Cold Water
Pipe
IN
ILD
BU
Cresnet

P
P -LS
CS
OL
NTR
CO STEM Z
G
SY Y
24

ICE
DEV
G
YZ
24 G
Z
N Y
TRO 24
G CRES
YZ
24
SP
P -L
CS
G
YZ
24

G
YZ
24

Pipe
Ground
Clamp

Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647

Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905


CSP-LSP
Cresnet® Lightning Strike Protector

Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647 All brand names, product names and trademarks are the property of their respective owners.

Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905 ©2024 Crestron Electronics, Inc. | 15 Volvo Drive | Rockleigh, NJ 07647

You might also like