Msds Selenium (Metal)
Msds Selenium (Metal)
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
For the full text of the H-Statements mentioned in this Section, see Section 16
Pictogram
Precautionary statement(s)
P261 Avoid breathing dust.
P301 + P310 IF SWALLOWED: Immediately call a POISON
CENTER/doctor.
P311 Call a POISON CENTER /doctor.
PT.SMART-LAB INDONESIA MSDS – SELENIUM (METAL) 1
MATERIAL SAFETY DATA SHEET
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
3.1 Substances
Synonyms : Selenium
Formula : Se
Molecular weight : 78.96 g/mol
CAS-No. : 7782-49-2
EC-No. : 231-957-4
For the full text of the H-Statements mentioned in this Section, see Section 16.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
If swallowed
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water.
Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in
section 11
4.3 Indication of any immediate medical attention and special treatment needed
No data available
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal
technique (without touching glove's outer surface) to avoid skin contact with this product.
Dispose of contaminated gloves after use in accordance with applicable laws and good
laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC
and the standard EN 374 derived from it.
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740, Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0.11 mm
Break through time: 480 min
Material tested:Dermatril® (KCL 740, Size M)
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be
selected according to the concentration and amount of the dangerous substance at the specific
workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use (EN 143)
respirator cartridges as a backup to engineering controls. If th full-face supplied air
respirator. Use respirators and components tested and approved under appropriate
government standards such as NIOSH (US) or CEN (EU).
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
pH No data available
Melting point/freezingpoint Melting point/range: 217 °C - lit.
Initial boiling point and boiling range 684.9 °C - lit
Flash point Not applicable
Evaporation rate No data available
Flammability (solid, gas) No data available
Upper/lower flammability or No data available
explosive limits No data available
Vapour pressure No data available
Vapour density No data available
Relative density 4.81 g/cm3 at 25 °C
Water solubility insoluble
Partition coefficient: noctanol/water log Pow: 5
Auto-ignition temperature No data available
Decomposition temperature No data available
Viscosity No data available
Explosive properties No data available
Oxidizing properties No data available
10.1 Reactivity
No data available
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
Skin corrosion/irritation
No data available(Selenium)
Carcinogenicity
This product is or contains a component that is not classifiable as to its classification.(Selenium)
IARC: 3 - Group 3: Not classifiable as to its carcinogenicity to humans (Selenium)
Reproductive toxicity
No data available(Selenium)
Aspiration hazard
May cause damage to organs through prolonged or repeated exposure.
Additional Information
RTECS: VS7700000
anemia, Vomiting, Diarrhoea, Cough, Difficulty in breathing, Acute selenium poisoning produces central
nervous system effects, which in signs of intoxication can include skin eruptions, lassitude, gastrointest
odorous ("garlic") breath, and partial loss of hair and nails. Chronic ex pallor, coating of the tongue,
anemia, irritation of the mucosa, lumbar p previously mentioned symptoms. Chronic contact with selenium
compounds ma moderate emotional instability., Dermatitis, garlic-like breath odor, pallor, nervousness,
depression(Selenium)
12.1 Toxicity
Toxicity to fish
mortality NOEC - Cyprinodon variegatus (sheepshead minnow) - 2 mg/l - 96.0 h(Selenium)
mortality LOEC - Oncorhynchus mykiss (rainbow trout) - 7.8 mg/l - 96.0 h(Selenium)
Toxicity to algae
EC50 - Pseudokirchneriella subcapitata - 99 mg/l - 72 h(Selenium)
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
Contaminated packaging
Dispose of as unused product.
14.1 UN number
ADR/RID: 3288 IMDG: 3288 IATA: 3288
14.2 UN proper shipping name
ADR/RID: TOXIC SOLID, INORGANIC, N.O.S. (Selenium)
IMDG: TOXIC SOLID, INORGANIC, N.O.S. (Selenium)
IATA: Toxic solid, inorganic, n.o.s. (Selenium)
14.3 Transport hazard class(es)
ADR/RID: 6.1 IMDG : 6.1 IATA: 6.1
14.4 Packaging group
ADR/RID: III IMDG: III IATA: III
14.5 Environmental hazards
ADR/RID: no IMDG Marine pollutant: no IATA: no
14.6 Special precautions for user
No data available
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.2 Chemical safety assessment
For this product a chemical safety assessment was not carried out
SELENIUM (METAL)
Revision : 00 Date: 05.03.2019 MSDS Number : 3152
HMIS (U.S.A.):
Health Hazard: 1
Fire Hazard: 0
Reactivity: 0
Personal Protection: -
Further information
The above information is believed to be correct but does not purport to be all inclusive and shall be used only as
a guide. The information in this document is based on the present state of our knowledge and is applicable to
the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties
of the product. PT. Smartlab Indonesia Corporation and its Affiliates shall not be held liable for any damage
resulting from handling or from contact with the above product. See www.sigmaaldrich.com and/or the reverse
side of invoice or packing slip for additional terms and conditions of sale.