Smallest & Lightest 4 Gas Monitor
Smallest & Lightest 4 Gas Monitor
Smallest & Lightest 4 Gas Monitor
Features
• Smallest & lightest 4 gas monitor
— 2.2" W x 2.55" H x 1.02" D, 3.52 ounces
• Simultaneous detection of 4 gases
— LEL, O2, H2S & CO
— H2 Compensated CO sensor available
• Simple 2-button operation
• Non-Compliance Indicator
• Alarms: audible, visual, & vibration
• 3 user adjustable alarm levels
• Impact resistant body with removable rubber boot
• Large LCD Auto-backlit display
• 25 hours of operation (Lithium-ion battery)
• Field replaceable sensors & filters
• Water and dust resistant design, IP66/68
• Stealth mode for law enforcement
• 3 Year warranty
Applications
4 Gas Monitor
World’s Smallest and Lightest • Personal monitoring • Oil and Gas
• Confined spaces • Water/wastewater
• Refineries/petrochemical • Fire services
• Utilities • Construction
OSHA defines the breathing zone as a ten inch radius around the
worker's nose and mouth, and requires that worker exposure monitoring
air samples be collected in the breathing zone. Air sampling filters
may be attached to the collar or lapel. Traditionally this means only a
Bump test H2 Compensated
single gas monitor would be small enough for a worker to practically
wear a gas monitor ‘In the breathing zone’. Now there is a 4 gas passed CO Sensor
monitor smaller than many single gas monitors. available
Health Check Battery Life:
Indicator 25 hours
The GX-3R is the worlds smallest 4 gas monitor weighing only 3.52
ounces and can comfortably be clipped within a worker's breathing
zone (2.2” W x 2.55” H x 1.02” D). It simultaneously monitors and
displays LEL combustibles, O2, CO (Hydrogen compensated CO also
available), and H2S. LCD
Autobacklit 3 visual
The GX-3R represents the latest evolution of gas detection technology display alarm LED's
utilizing a new generation of micro sensors. The LEL sensor has a
unique design with two active filaments in one sensor to increase it’s
resistance to silicone poisoning. If one filament gets poisoned the
Removable 2-Glove
second filament takes over. The new O2 sensor is electrochemical with
Impact resistant friendly
a 3 to 5 year life span. H2S and CO are now available in a combo
boot button
micro sensor.
operation
Safety supervisors will appreciate the non-compliance indicator. The
instrument flashes it’s 3 LED lights every 30 seconds in the following
conditions; if the instrument has not been bump tested, or if calibration Easy to replace Audible Replaceable
is due, or if there was a gas alarm event. The 3 LED lights will continue color-coded Alarm port Sensor/Filters
to flash once every 30 seconds until the non-compliance condition has sensors
been resolved. The 30 second interval is adjustable.
RKI Instruments, Inc. • 33248 Central Ave. Union City, CA 94587 • Phone (510) 441-5656 • (800) 754-5165 • Fax (510) 441-5650
World Leader In Gas Detection & Sensor Technology
www.rkiinstruments.com
GX-3R Model
(CO) Carbon Monoxide(CO) Hydrogen Sulfide(H2S) H2S Combustible Gases Oxygen
Gas Detected H2 Compensated Only (Methane as standard)
Dual Sensor (O2)
Sensor Slot 1 2 3
Detection
EC Dual EC EC Catalytic combustion Electrochemical cell
Principle
Detection Range 0 ~ 2,000 ppm 0 ~ 200.0 ppm 0 ~ 100% LEL 0 ~ 40.0% Vol.
(Increments) (1 ppm) (0.1 ppm) (1% LEL) (0.1%)
Sampling Method Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)
Display Digital LCD displays with 7 segment plus 14 segment plus icon
Gas Alarm: Flashing LEDs, continuous buzzer (100 db @ 30 cm), flashing gas value, vibration
Display of Alarm Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message
Operating Temp. -20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment)
& Humidity -40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)
Power Source Lithium-ion battery, Approx. 25 hours after a 3 hour full charge
Dimension 2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm), 3.52 ounces (approx. 100 g) without rubber boot
& Weight 2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm), 3.70 ounces (approx. 105 g) with rubber boot
Case Material Dust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft
Datalogging Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends
Standard
Alligator clip, protective rubber boot, charger, and calibration adapter
Accessories
Authorized Distributor:
(800) 754-5165
www.rkiinstruments.com