Micro Fused: Pressure Transmitter
Micro Fused: Pressure Transmitter
Micro Fused: Pressure Transmitter
MICRO FUSED
PRESSURE TRANSMITTER
Description Application
PX4 pressure transmitter is based on micro-fused Machine tools
technology with excellent long-term stability, providing
high overpressure capability and outstanding Hydraulics and pneumatics
durability despite substantial shock and vibration. The Plant control and monitoring
PX4's robust stainless steel structure contains no
filling oils and no internal O-rings. Refrigeration systems
Pumps and compressors control
This highly reliable transmitter is designed for use
in hydraulic and almost all industrial applications, Energy management systems
offering accurate pressure measurement over a wide
temperature range, even under harsh environmental HVAC systems
conditions. It is an ideal choice for applications where
better performance, compact size, and low cost are
essential.
Main Feature
• Micro-fused Technology • Pressure Type: Gauge, Sealed Gauge
• Measuring Range: 0 ... 10 bar to 0 ... 1000 bar • Accuracy @ 25°C: ≤ ±0.5, ≤ ±1 %FS
Structure Material
Wetted part
Isolation Diaphragm: Stainless Steel 17-4PH
Pressure Port: Stainless Steel 17-4PH / Stainless Steel 304
Sealing Ring: FKM / NBR
Non-Wetted part
Housing: Stainless Steel 304
Cable: Polyurethane (PUR), 5-core, φ5 mm
Output Signal
Output Signal Power Supply Output Format Load Resistance Transmission Distance
4 … 20 mA 2-wire ≤ Supply - 8 )
( (Ω)
/0.02 <1000 m
(@24 VDC, load 250Ω )
8 … 33 VDC
0.5 … 4.5 VDC
I Out
2 3 Black Black 3 3 1 (A) 3 (C)
+V Out
Code Definition
+V Supply Voltage +
N.C No Connection
Grounding
Electromagnetic Compatibility
Code Test Item Standard
13: G 1/4“ A, Male, std. ISO 1179-2 23: 1/4“ NPT, Male, std. ANSI/ASME B1.20.1
14: G 3/8“ A, Male, std. ISO 1179-2 04: G 1/2“ B, Male, std. EN 837 05: M20 x 1.5, Male, std. EN 837
The maximum torque applied during the disassembly of the transmitter is 30N•m to 35N•m.
Dimension
(unit:mm)
Pressure Range
e.g. (0 … 400) Material
Diaphragm Pressure Port Housing
62 SS 17-4PH SS 304 SS 304
66 SS 17-4PH SS 17-4PH SS 304
Unit XX Customized
kPa mbar
MPa bar
kgf/cm² psi Electrical Connection
D2 DIN EN 175301-803, Form C
M2 M12x1, 4-pin, Mat. Steel
Power Supply P1 Packard Metri-Pack, 3-pin
5 ± 0.1 VDC S04 C2 Cable Outlet, Mat. PUR
8 … 33 VDC S09 XX Customized
11 … 33 VDC S14 Extension Cable
Customized XX null Without Assorted Connector
B1 With Assorted Connector
B2 Female Straight Connector M12x1, 4-pin
Output Signal Integrated with 2m Cable
4 … 20 mA / 2-wire C01
B3 Female Right Angle Connector M12x1,
0 … 10 VDC / 3-wire V01 4-pin Integrated with 2m Cable
0.5 … 4.5 VDC / 3-wire V07
Ln n means cable length when electrical
Customized XX connection is C2 type (exc. L0 = 0.5 m)
XX Customized
Accuracy
≤ ±0.5 %FS A5
Snubber
≤ ±1 %FS A6
null Without Snubber
Customized XX
S With Snubber
C Customized Pressure Channel
Process Connection
G 1/2“ B, Male, std. EN 837 04
M20 x 1.5, Male, std. EN 837 05
G 1/4“ A, Male, std. ISO 1179-2 13
G 3/8“ A, Male, std. ISO 1179-2 14
1/4" NPT, Male, std. ANSI/ASME B1.20.1 23
Customized XX
Notes:
1. The error band in the entire temperature zone (- 40 … 125 °C) is ≤ ±2 %FS.
If you have special requirements for the error of a certain temperature zone, please consult with our company for
customization.
2. Products with an IP68 protection class are available; please consult with our company to customize this demand.
3. For products which are powered by S04 and feature cable connections, the cable length must be less than 10m.
4. If you require a calibration certificate for the ordered product or have any other special requirements, please reach
out to our company for assistance.