Micro Fused: Pressure Transmitter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

PX4

MICRO FUSED
PRESSURE TRANSMITTER

Description Application
PX4 pressure transmitter is based on micro-fused Machine tools
technology with excellent long-term stability, providing
high overpressure capability and outstanding Hydraulics and pneumatics
durability despite substantial shock and vibration. The Plant control and monitoring
PX4's robust stainless steel structure contains no
filling oils and no internal O-rings. Refrigeration systems
Pumps and compressors control
This highly reliable transmitter is designed for use
in hydraulic and almost all industrial applications, Energy management systems
offering accurate pressure measurement over a wide
temperature range, even under harsh environmental HVAC systems
conditions. It is an ideal choice for applications where
better performance, compact size, and low cost are
essential.

Main Feature
• Micro-fused Technology • Pressure Type: Gauge, Sealed Gauge

• Measuring Range: 0 ... 10 bar to 0 ... 1000 bar • Accuracy @ 25°C: ≤ ±0.5, ≤ ±1 %FS

• Media Temperature: –40°C ... +125°C • Process Connection:


G 1/2“ B, Male, std. EN 837
• Output Signal:
M20 x 1.5, Male, std. EN 837
4 … 20 mA
0 … 10 VDC G 1/4“ A, Male, std. ISO 1179-2
0.5 … 4.5 VDC G 3/8“ A, Male, std. ISO 1179-2
0.5 … 4.5 VDC Ratiometric 1/4“ NPT, Male, std. ANSI/ASME B1.20.1

• No Internal Seals or O-rings • Electrical Connection: DIN EN 175301-803, Form C


M12x1, 4-pin, Mat. Steel
• Compact Design, Low Cost
Packard Metri-Pack, 3-pin

• High Overpressure Resistance Cable Outlet (Default 0.5 m)

• High Resistance to Shock and Vibration • Non-oil Filled Design

1 PX4 MICRO FUSED PRESSURE TRANSMITTER ww.hogller.com


Technical Specifications
Pressure Type Gauge, Sealed Gauge
Pressure Range 0 … 10 bar to 0 … 1000 bar
Pressure Range ≤ 35 bar : Gauge
Pressure Range > 35 bar : Sealed Gauge
Overpressure 3 x FS (Pressure Range ≤ 50 bar)
2 x FS (50 bar ≤ Pressure Range ≤ 750 bar)
1.5 x FS (750 bar ≤ Pressure Range ≤ 1000 bar)
Burst Pressure 5 x FS (Max. 2000 bar)
Accuracy @ 25°C ≤ ±0.5 %FS, ≤ ±1 %FS (Pressure Range < 16 bar)
Total Error Band ≤ ±1 %FS (@ -10 … +80 °C)
Long Term Stability ≤ ±0.25 %FS/year
Operation Temperature -40 … +125 °C
Storage Temperature -40 … +125 °C
Compensation Temperature -10 … +80 °C
Vibration Resistance 20 g (20 … 2000 Hz) (GB/T2423.10/IEC60068-2-6)
Shock Resistance 100 g / 6 ms (GB/T2423.5/IEC60068-2-27)
Protection Class IP65
IP67, IP68 (Optional)
Insulation Resistance 100 MΩ, 500 V
Impact Life 10 million times
Weight ≤ 100 g

Structure Material
Wetted part
Isolation Diaphragm: Stainless Steel 17-4PH
Pressure Port: Stainless Steel 17-4PH / Stainless Steel 304
Sealing Ring: FKM / NBR

Non-Wetted part
Housing: Stainless Steel 304
Cable: Polyurethane (PUR), 5-core, φ5 mm

Output Signal
Output Signal Power Supply Output Format Load Resistance Transmission Distance

4 … 20 mA 2-wire ≤ Supply - 8 )
( (Ω)
/0.02 <1000 m
(@24 VDC, load 250Ω )
8 … 33 VDC
0.5 … 4.5 VDC

0 … 10 VDC 11 … 33 VDC 3-wire >10kΩ <5 m


(@24 VDC, load>10kΩ )

0.5 … 4.5 VDC 5 ± 0.1 VDC

2 PX4 MICRO FUSED PRESSURE TRANSMITTER ww.hogller.com


Electrical Connection
D2 C2 M2 P1
DIN EN 175301-803, Form C Cable Outlet, Mat. PUR M12x1, 4-pin, Mat. Steel Packard Metri-Pack, 3-pin

Current Voltage Current Voltage Current Voltage Current Voltage


2-wire 3-wire 2-wire 3-wire 2-wire 3-wire 2-wire 3-wire

+V 1 1 Red Red 1 1 2 (B) 2 (B)

I Out
2 3 Black Black 3 3 1 (A) 3 (C)
+V Out

GND N.C 2 N.C White N.C 2 N.C 1 (A)

Code Definition

+V Supply Voltage +

GND Supply Voltage -

I Out Current Output

+V Out Vlotage Output

N.C No Connection

Grounding

Electromagnetic Compatibility
Code Test Item Standard

1 Electrostatic Discharge Immunity GB/T 17626.2/IEC 61000-4-2

2 Radio-frequency Field GB/T 17626.3/IEC 61000-4-3

3 Power Frequency Magnetic Field GB/T 17626.8/IEC 61000-4-8

4 Immunity of Electrical Fast Pulse Group GB/T 17626.4/IEC 61000-4-4

5 Surge Immunity GB/T 17626.5/IEC 61000-4-5

6 RF Induction Conduction Anti-harassment GB/T 17626.6/IEC 61000-4-6

3 PX4 MICRO FUSED PRESSURE TRANSMITTER www.hogller.com


Process Connection
( unit:mm )

13: G 1/4“ A, Male, std. ISO 1179-2 23: 1/4“ NPT, Male, std. ANSI/ASME B1.20.1

14: G 3/8“ A, Male, std. ISO 1179-2 04: G 1/2“ B, Male, std. EN 837 05: M20 x 1.5, Male, std. EN 837

The maximum torque applied during the disassembly of the transmitter is 30N•m to 35N•m.

Dimension
(unit:mm)

D2: DIN EN 175301-803, Form C C2: Cable Outlet, Mat. PUR

M2: M12x1, 4-pin, Mat. Steel P1: Packard Metri-Pack, 3-pin

4 PX4 MICRO FUSED PRESSURE TRANSMITTER ww.hogller.com


How to Order
PX4 - X - (X...X) X - XXX - XXX - XX - XX - X - XX-XX - XX - X

Pressure Type Sealing Material


Gauge G W Without Seal
Sealed Gauge S N NBR
F FKM

Pressure Range
e.g. (0 … 400) Material
Diaphragm Pressure Port Housing
62 SS 17-4PH SS 304 SS 304
66 SS 17-4PH SS 17-4PH SS 304
Unit XX Customized
kPa mbar
MPa bar
kgf/cm² psi Electrical Connection
D2 DIN EN 175301-803, Form C
M2 M12x1, 4-pin, Mat. Steel
Power Supply P1 Packard Metri-Pack, 3-pin
5 ± 0.1 VDC S04 C2 Cable Outlet, Mat. PUR
8 … 33 VDC S09 XX Customized
11 … 33 VDC S14 Extension Cable
Customized XX null Without Assorted Connector
B1 With Assorted Connector
B2 Female Straight Connector M12x1, 4-pin
Output Signal Integrated with 2m Cable
4 … 20 mA / 2-wire C01
B3 Female Right Angle Connector M12x1,
0 … 10 VDC / 3-wire V01 4-pin Integrated with 2m Cable
0.5 … 4.5 VDC / 3-wire V07
Ln n means cable length when electrical
Customized XX connection is C2 type (exc. L0 = 0.5 m)
XX Customized

Accuracy
≤ ±0.5 %FS A5
Snubber
≤ ±1 %FS A6
null Without Snubber
Customized XX
S With Snubber
C Customized Pressure Channel

Process Connection
G 1/2“ B, Male, std. EN 837 04
M20 x 1.5, Male, std. EN 837 05
G 1/4“ A, Male, std. ISO 1179-2 13
G 3/8“ A, Male, std. ISO 1179-2 14
1/4" NPT, Male, std. ANSI/ASME B1.20.1 23
Customized XX

5 PX4 MICRO FUSED PRESSURE TRANSMITTER ww.hogller.com


Example
PX4-G-(0 … 16)bar-S09-C01-A5-13-D2-B1-66-F

Gauge Pressure Transmitter, Range: 0 … 16 bar


Supply: 8 … 33 VDC, Output: 4 … 20 mA, Accuracy: ≤ ±0.5 %FS
Process Connection: G 1/4" A Male, Without Snubber
Electrical Connection: DIN EN 175301-803 Form C With Assorted Connector
Wetted Parts Material: Stainless Steel 17-4PH + FKM Sealing

Notes:
1. The error band in the entire temperature zone (- 40 … 125 °C) is ≤ ±2 %FS.
If you have special requirements for the error of a certain temperature zone, please consult with our company for
customization.
2. Products with an IP68 protection class are available; please consult with our company to customize this demand.
3. For products which are powered by S04 and feature cable connections, the cable length must be less than 10m.
4. If you require a calibration certificate for the ordered product or have any other special requirements, please reach
out to our company for assistance.

6 PX4 MICRO FUSED PRESSURE TRANSMITTER ww.hogller.com