Ac625 6
Ac625 6
Ac625 6
MODEL AC625-6
kVA 625
Standby
Power kW 500
Pf. 0.8 kVA 563
Prime
kW 450.4
Standby: Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 .
Prime: Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046.
Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
www.aksapowergen.com
ENGINE
CUMMINS
Model QSX15G9
ALTERNATOR
Design Brushless single bearing, revolving field
Stator 2/3 pitch
Rotor Single bearing, flexible disc
Insulation System Class H
Standard Temperature Rise 125 - 163°C Continuous
Exciter Type Self Excited
Phase Rotation A (U), B (V), C (W)
Alternator Cooling Direct drive centrifugal blower fan
AC Waveform Total Harmonic Distortion No load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF) <50 per NEMA MG1-22.43
Telephone Harmonic Factor (THF) <2%
Brushless, single bearing system, flexible disc, 4 poles Impregnation with tropicalised epoxy varnish
Insulation class H Solid state Automatic Voltage Regulator
Standard degree of protection IP21 (*IP22/IP23 is available.) Stator winding with 2/3 pitch for improved harmonics
Self-exciting and self-regulating
www.aksapowergen.com
CONTROL SYSTEM
Control supervision and protection panel is mounted on the genset base frame.
The control panel is equipped as follows:
OPTIONAL EQUIPMENTS
www.aksapowergen.com
CHASSIS
The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame
Anti-vibration pads are fixed between the engine/ alternator feet and the base frame
Base frame design incorporates an integral fuel tank (Up to 1000 kVA)
The generating set can be lifted or carefully pushed / pulled by the base frame
Dial type fuel gauge and drain plug on the fuel tank
Forklift pockets within base frame (up to 500kVA)
DIMENSIONS
OPEN TYPE
DIMENSIONS (LxWxH) mm 3296x1550x2103
DRY WEIGHT kg 3770
CANOPY
All canopy parts are designed with modular principles Exhaust silencer is protected against environment influences
Without welding assembly Thermally insulated engine exhaust system
Doors on each side Emergency stop push button is installed outside of the canopy
All metal canopy parts are painted by electrostatic Easy lifting and moving
polyester powder paint Easy maintenance and operation